Sei sulla pagina 1di 6

Coolerado RF100 Adapter Kit

SUBMITTAL DATA SHEET


JOB NAME: PURCHASER: ENGINEER: SUBMITTED TO: UNIT DESIGNATION:
Building Energy

LOCATION: ORDER NO: FOR: REF: APPROVAL: DATE: SCHEDULE NO:


_____________ _____________ _____________ _____________ _____________ _____________ _________ CFM

CONSTRUCTION: MODEL NO:


______________ ______________ ______________ ______________

COOLERADO TRAINED INSTALLER:

Coolerado Configuration

Energy Management System Model . . . . . . . . . Thermostat Model . . . . . . . . . . . . . . . . . . . . . . Stages of Cooling . . . . . . . . . . . . . . . . . . . . . . . Cooling Set Point(s) . . . . . . . . . . . . . . . . . . . . . Night Set Back Point(s) . . . . . . . . . . . . . . . . . . Occupied/Unoccupied Hours . . . . . . . . . . . . . . Minimum Outdoor Air . . . . . . . . . . . . . . . . . . . .
Current Rooftop Units

Number of C60s installed . . . . . . . . . . . . . . . . Number of M50s installed . . . . . . . . . . . . . . . . Number of M30s installed . . . . . . . . . . . . . . . . Number of RF100s installed . . . . . . . . . . . . . .

C60 / M50 / M30 Electrical & Water Specs

Number of units / 5 tons . . . . . . . . . . . . . . . . . Number of units / 10 tons . . . . . . . . . . . . . . . . Number of units / 20 tons . . . . . . . . . . . . . . . . Make / Model / Year . . . . . . . . . . . . . . . . . . . . Electrical Service (Volts/Phase) . . . . . . . . . . . . . . . Supply/Return Ducts (Horizontal/Vertical) . . . . . . . . Horizontal Discharge Panels (Yes/No) . . . . . . . . . Power Exhaust (Yes/No) . . . . . . . . . . . . . . . . . . . Roof Slope (i .e .: Down Front to Back) . . . . . . . . . . . . Plumbing Vent Location (i .e .: Back Center) . . . . . . . Roof Construction and Available Footprint . . . .

_____________ _____________ _____________ _____________ _____________ _____________ _____________ _____________ _____________ _____________ _____________

ELECTRICAL 200-240V, 50-60Hz, 790W max ., 4 .0 Amp, EC Motor * IFM Max Continuous BHP *** . . . . . . . . . . . . . . . . . . . . . . . . . .1 IFM Max Continuous BHP ** . . . . . . . . . . . . . . . . . . . . . . . . 0 .75 FLA * . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Power Supply (max . overcurrent protection) * . . . . . . . . . . . .20 Min . unit disconnect FLA * . . . . . . . . . . . . . . . . . . . . . . . . . . .10 Ampacity * . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 - 20 Min . wire size * . . . . . . . . . . . . . . . . . . . . . . 14 AWG w/ ground External Fusing * . . . . . . . . . . . . . . . . . . . . . . . . . 10 - 20 amp Phase * . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 HZ (require to spec) * . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50/60 Power input requirement (watts) (C60 & M50) * . . . . . . . . . .790 Power input requirement (watts) (M30) * . . . . . . . . . . . . . . .550 EC, backward curved impeller, 3D, 500mm diameter * . . . . . WATER Minimum Flow with 1/2 NPT Connection *** . . . . . . . . . 1 .7 GPM Minimum Flow with 1/2 NPT Connection ** . . . . . . . . . .1 GPM Supply Line Pressure * . . . . . . . . . . . . . . . . . . . . . . 40 - 60 PSI
*** C60 and M50 only ** M30 only * C60, M50 and M30

RF100 Electrical

RF100 Adapter Electrical:

24V AC From RTU ~ 20VA 20V DC From Coolerado Fan 100 lbs .

RF100 Weight RF100 Weight:

RF100 Standard Features Actuated dampers in adapter box deliver Coolerado free-cooling

when conditions are favorable .


Under more humid conditions, RF100 control logic directs

Coolerado pre-cooling air to the RTU coil for final cooling .


Provides high efficiency hybrid Coolerado cooling with any RTU

and thermostat combination up to 25 tons .


Easy to connect low-voltage power control wiring . Removable adapter box top facilitates control wiring .
Revised April, 2011 | Design and specifications may change without notice . RF100 Adapter Kit Submittal Data Sheet | Page 1 of 6

Coolerado RF100 Adapter Kit - Sequence of Operation

Revised April, 2011 | Design and specifications may change without notice .

RF-100 Adapter Kit Submittal Data Sheet | Page 2 of 6

Coolerado RF100 Adapter Kit - Operations Concept

T-Stat in bldg:
1st Stage Compressor (Coolerado Pre Cooling) 2nd Stage Compressor (Coolerado Pre Cooling) Heating

RTU
Condenser

RTU Retrot
10 Ton 5 Ton

M50/C60

or
Pre Cool

Free Cool

Building Heat Supply Side

DX

(Winter Make UP Air)

Economizer Off

Revised April, 2011 | Design and specifications may change without notice .

Filter

Outside Air

Return Side

RF-100 Adapter Kit Submittal Data Sheet | Page 3 of 6

Coolerado RF100 Adapter Kit - Field Wiring Connections

(pg 1 of 2)

Revised April, 2011 Design and specifications may change without notice .

RF100 Adapter Kit Submittal Data Sheet | Page 4 of 6

Coolerado RF100 Adapter Kit - Field Wiring Connections

(pg 2 of 2)

Revised April, 2011 Design and specifications may change without notice .

RF100 Adapter Kit Submittal Data Sheet | Page 5 of 6

Coolerado RF100 Adapter Kit - Dimensional Drawings

ISOMETRIC VIEW

SECTION A-A

SECTION B-B

RIGHT SIDE VIEW

FACE VIEW Revised April, 2011 Design and specifications may change without notice .

RF100 Adapter Kit Submittal Data Sheet | Page 6 of 6