NCR SelfServ 34 ATM Site Preparation Datasheet (B006-6921-B000)

Walk-up version with CEN Security Enclosure.


This Site Preparation Datasheet is to be used in conjunction with the following documents: NCR SelfServ 34 ATM Site Preparation (B006-6586) NCR SelfServ 34 Installation Guide (B006-6590) NCR SelfServ 32, 34 and 38 ATMs Site Preparation Requirements (B006-6670)

COLLAR DIMENSIONS AND CLEARANCE


B, C A N Collar Tolerance The wall and floor need to be smooth and even as the collar has a tolerance of +/- 4 mm (0.2 in. (+/- 0.5)) at the top and bottom, with 0 mm (0.0 in. (0)) at its centre. Note: The collar cannot accommodate large dips or depressions in the wall. M 725 mm (28.5 in.) 47 mm (1.9 in.) 75 mm (3.0 in.)

Standard Collar & Logo Collar


Exterior Wall Clearance

ATM DIMENSIONS

Package Dimensions
ATM and Pallet Height 1702 mm (67.0 in.) ATM, Pallet and Carton 1836 mm (72.3 in.) J H F, G (LHS) I F, G (RHS)

62 mm (2.4 in.)

L K

10 mm (0.4 in.) 45 mm (1.8 in.)


626 mm (24.6 in.) A 38 mm (1.5 in.)

1300 mm (51.2 in.) Standard Sleeve

800 mm (31.5 in.)

Width

977 mm (38.5 in.) 140.5 mm (55.3 in.)

1187 mm (46.7 in.) Short Sleeve Short Sleeve

Length

Standard Sleeve 65 mm (2.6 in.) 605 mm (23.8 in.) 773 mm (30.4 in.) 47 mm (1.9 in.)

Height and Depth to Main Facia Items

Facia Item Locations for Voice Guidance Distance from No. 5 Key 378 mm (14.9 in.) Clock Face Position (relative to No.5 Key) 12

ACCESS FOR ALL


Note: Overall depth dimension includes the door lock. Overall width dimension includes the top door hinge. A B

30 mm (1.2 in.)

30 mm (1.2 in.)

B Base of ATM A B Short Sleeve 239 mm (9.4 in.) Standard Sleeve 352 mm (13.86 in.)

Height Depth (from base of ATM) (from front of collar) 207 mm (8.1 in.) 147 mm (5.9 in.)

Statement Exit or Passbook Entry and Exit 1079 mm (42.5 in.) Cheque Entry Coin Exit 381 mm (15.0 in.) Touchscreen Display 1060 mm (42.7 in.) 1074 mm (42.3 in.) 1029 mm (40.5 in.) 1008 mm (39.7 in.) 961 mm (37.8 in.) 954 mm(37.6 in.) 749 mm (29.5 in.) 749 mm (29.5 in.) 733 mm (28.7 in.) 714 mm(28.1 in.) 824 mm (32.4 in.) 874 mm (34.4 in.) 883 mm (34.8 in.) 958 mm (37.7 in.) 1079 mm (42.5 in.)

380 mm (15.0 in.)

868 mm (34.2 in.)

65 mm (2.6 in.)

Minimum clear wall area required around collars for installing and servicing the ATM. 426 mm (16.8 in.) 11

Standard Collar Logo Collar

1233 mm (48.5 in.) 1234 mm (48.6 in.)

267 mm (10.5 in.)

168 mm (6.6 in.) 220 mm (8.7 in.) N/A 214 mm (8.4 in.) 168 mm (6.6 in.) 163 mm(6.4 in.) 99 mm (3.9 in.) 99 mm (3.9 in.) 21 mm (0.8 in.) 42 mm(1.7 in.) 81 mm (3.2 in.) 83 mm (3.3 in.) 68 mm (2.7 in.) 87 mm (3.4 in.) 117 mm (4.6 in.) 333 mm (13.1 in.) 10 306 mm (12.0 in.) 144 mm (5.7 in.) LHS 184 mm (7.2 in.) RHS 217 mm (8.5 in.) N/A 264 mm (10.4 in.) N/A 296 mm (11.7 in.) 355 mm (14.0 in.) 446 mm (18.3 in.) 9 3 9 N/A 2 N/A 2 1 1 Exterior Wall Clearance
30 mm (1.2 in.)

1498 mm (59.0 in.)

1171 mm (46.1 in.)

Standard Sleeve 843 mm (33.2 in.)

307 mm (12.1 in.) Touchscreen Display 381 mm (15.0 in.) Display - Top FDK

N/A

ADA Collar
Exterior Wall Clearance

730 mm (28.7 in.) 37 mm (1.5 in.)

129 mm (5.0 in.) 60 mm (2.36 in.)

Short Sleeve
E

659 mm (25.9 in.)

667 mm (26.3 in.)

267 mm (10.5 in.)

664 mm (26.1 in.)

307 mm (12.1 in.) Display - Top FDK F G Cash Exit or Entry Envelope Exit or Entry Fingerprint Reader No. 5 Key Audio Jack Plug Camera Contactless Card Reader Card Reader Receipt

10 mm (0.4 in.) 45 mm (1.8 in.)

630 mm (24.8 in.)

1234 mm (48.6 in.)

38 mm (1.5 in.)

770 mm (30.3 in.)

380 mm (15.0 in.)

865 mm (34.1 in.)

H I J K

30 mm (1.2 in.)
Base of ATM

Short Sleeve 185 mm (7.3 in.) Standard Sleeve 298 mm (11.73 in.)

Floor Loading
Maximum weight Floor Loading

CEN Grade I and CEN Grade L 878 kg (1936 lb.) 1425 kg/m2 (292 lb./ft2 )

CEN Grade III and CEN Grade IV Spanish Certified 1036 kg (2285 lb.) 1682 kg/m (345 lb./ft )
2 2

L M N

Advert Collar

725 mm (28.5 in.)

47 mm (1.9 in.) 38 mm (1.5 in.)

75 mm (3.0 in.)

276 mm (10.9 in.)

INSTALLATION CATEGORIES
The SelfServ 34 ATM can be installed through an existing 5886 hole in the wall, depending on the size of the hole that was cut for the previous installation. However, for ease of installation, NCR recommends a larger hole in the wall; for this reason, a larger hole in the wall is specified for new installations. Note: For a successful installation through an existing hole in the wall, the original ATM must have been installed in compliance with the relevant site preparation manual as listed below: B006-6191 - NCR Personas M Series 5886 ATM, Site Preparation B006-6328 - NCR Personas M Series 5886 Drive-Up Site Preparation and Installation B006-6066 - NCR Personas 88 ATM, Site Preparation Manual - Stage 1 B006-6128 - NCR Personas 88 ATM, Site Preparation Manual The physical installation of the ATM is divided into four categories. 1. A new installation of a SelfServ 34 walk-up ATM at the lowered height. 2. An installation where a SelfServ 34 walk-up ATM replaces a 5886 walk-up ATM at the lowered height. The plinth must be replaced with a new one to position the SelfServ 34 keyboard at the lowered height. This category also includes a replacement of a 5X84 or a 5081 at the lowered height. 3. A new installation of a SelfServ 34 walk-up ATM at the optimum height. This height does not comply with the regulations listed in the "Lowered Heights section. 4. An installation where a SelfServ 34 walk-up ATM replaces a 5886 walk-up ATM at the optimum height. This height does not comply with the regulations listed in the "Lowered Heights section. The plinth must be replaced with a new one to position the SelfServ 34 keyboard at the optimum height. This category also includes a replacement of a 5X84 or a 5081 at the optimum height. Installing Through a Glass Wall If you are installing your ATM through a glass wall you may require a suitable glass support (normally a steel collar) to sit between the ATM collar and the glass. The requirement for this support should be determined by the architect. If required, any such support should be sourced locally. Service Access Panels and Facia Aperture There are two service panels, one either side of the top-box. The monitor and bezel can be unlatched and removed to allow access behind the facia.

CONNECTING THE CABLES


Because there is a limited side clearance when the ATM is being installed within a minimum footprint clearance area, cable connections must be carried out before the unit is moved into its final location. Cables must be grounded to make sure that the ATM meets EMC requirements. Make sure that the power supply cable is not connected to the AC outlet while you are connecting it to the ATM. Harness Channel Frame AC Inlet Filter Power Cable
30 mm (1.2 in.)

840 mm (33.1 in.)

1447 mm (57.0 in.)

45 mm (1.8 in.)

30 mm (1.2 in.)

Base of ATM

Short Sleeve 239 mm (9.4 in.) Standard Sleeve 352 mm (13.86 in.)

Open Advert Collar


Exterior Wall Clearance 725 mm (28.5 in.) 47 mm (1.9 in.)

75 mm (3.0 in.) 38 mm (1.5 in.)

Other Cables

Grounding

100 mm (3.9 in.)


855 mm (33.7 in.) P Clamp

291 mm (11.5 in.)

1462 mm (57.6 in.)

210 mm (8.3 in.)

45 mm (1.8 in.)

M4 Thread Forming Screw

30 mm (1.2 in.)

30 mm (1.2 in.)

Base of ATM

Short Sleeve 239 mm (9.4 in.) Standard Sleeve 352 mm (13.86 in.)

ENVIRONMENTAL REQUIREMENTS Temperature and Humidity


Normal Operating Range Interior Environment Exterior Environment Freestanding Drive-Up ATMs Lobby & Through-the-Wall Through the Wall ATMs ATMs 10C to 40C (50F to 104F) See Note 1. 20% to 80% See Note 2. 26C (79F) max.

POWER REQUIREMENTS
Voltage transients, line noise, surges, sags, impulses, and spikes may be experienced routinely or sporadically. When such phenomena occur, the use of protective devices may be required to ensure proper operation of the equipment. AC Power Requirements The maximum current requirements at the stated input voltages are: 10A at 120V 6.3A at 230V The maximum inrush current is 100A Input Voltage Setting The ATM can operate from the following input mains voltages: 90V to 136V at 50/60Hz 180V to 264V at 50/60Hz. Power Cable The ATM is supplied either as a 120V or a 220-240V unit. 120V ATMs are supplied with a power cable fitted with a NEMA type 5-15P power source connector. 220-240V ATMs are supplied with an unterminated power cable. Information about suitable power connectors is supplied with the accessories. The power cable supplied is 3 m (9.8 ft) in length. If it is necessary to increase this length to meet site requirements, then the extension must satisfy local or country regulations. WARNING This equipment must be grounded (earthed) Grounding Requirements The ATM operates from a single phase, 3 wire supply; live, neutral and ground. The power requirements of this unit will normally permit it to operate within existing wiring configurations and from existing branch mains outlets providing: 1. Where the supply is provided from a general purpose distribution panel, then the other branch circuits from this panel must not be used to support heavy inductive loads such as air conditioners, elevators, microwave ovens, and so on. Nor may such equipment be operated on the same branch circuit as the ATM. 2. If using distribution panels, all branch circuit grounding conductors must be connected to an insulated terminal strip in the distribution panel. The grounding conductor from the distribution panel to the building ground point must be at least equal in size to the power conductor necessary to supply the NCR system. Note: The building ground point can affect data integrity. For additional information, refer to the Data Line Transient Protection section in the publication NCR SelfServ 32, 34 and 38 ATMs Site Preparation Requirements.

BOLT HOLE LOCATIONS


Security Bolts The ATM should be bolted to the floor or plinth, through the `A' holes, using four bolts with anchor washers. The floor or plinth must be capable of withstanding the loading imposed by the anchor points for the bolts. The bolts and anchors must be supplied by the owning organisation. If an adjustable plinth is used, it must be bolted to the floor. The minimum specification for bolts, to secure the ATM to a concrete floor, is high tensile M16 (5/8 in.) bolts with appropriate anchor washers of 6 mm (0.2 in.) minimum thickness. It is recommended that these bolts be a minimum depth of 150 mm (5.9 in.) and that either resin anchor bolts or rawl type bolts are used. Note 1: Bolting of CEN security enclosures should comply with the requirements of EN 1143-1 (CEN Safe Burglary Standard). Note 2: For CEN III security enclosures, the centre bolt hole `B' in the floor is counterbored to a larger diameter than the other four. This enables a locally sourced security alarm sensor to be fitted through the hole. 800 mm

170 mm (6.7 in.) A

770 mm (30.3 in.) 500 mm (19.7 in.) 285 mm (11.2 in.) 65 mm (2.6 in.) C A 150 mm (5.9 in.) 33 mm (1.3 in.) B 247 mm (9.7 in.) 500 mm (19.7 in.)

Temperature (dry bulb)

Without air conditioning -35C to 45C -35C to 50C (-31F to 113F) (-31F to 122F) With air conditioning See Note 3. -35C to 50C (-31F to 122F) 10% to 100% See Note 3. 26C (79F) max. 10% to 100% 26C (79F) max.

(31.5 in.)
Detail of Hole A (All CEN Safes) Detail of Hole C (CEN III Only) Enables a security alarm sensor to be fitted.

Relative humidity Dew point temperature restriction

250 mm (9.8 in.)

20 mm (0.78 in.)

45 mm (1.8 in.)

25 mm (0.98 in.)

60 mm (2.4 in.)

150 mm (5.9 in.)


45 mm (1.77 in.) 45 mm (1.77 in.)

250 mm (9.8 in.) A 19 mm (0.7 in.)

Note 1: If severe environment is fitted, the minimum temperature is 0C (32F). Note 2: For Through the Wall ATMs, the humidity inside the building is restricted to a maximum of 30% at an outside temperature of -35C (-31F), with a linear relationship between temperature and humidity to a maximum humidity at 0C (32F). Note 3: If a passbook printer is fitted, the minimum exterior temperature is 0C (32F) and the maximum relative humidity is 80%. ATM installation through an exterior wall must meet the requirements of both the Interior and Exterior (through the wall) environments. Transit Range Storage Range (Up To Three Months) (Up To One Week) Temperature Relative Humidity -10C to 50C (14F to 122F) 10% to 90% -40C to 60C (-40F to 140F) 5% to 95% Extreme Power On Range (Up To One Hour) 0C to 45C (32F to 113F) 10% to 95%.

E
28 mm (1.1 in.) 28 mm (1.1 in.)

SERVICE CLEARANCES (Typical LH PPD/BNA + RH Disp Config)


Important Notice to Users. If it is likely that the ATM will be upgraded with new modules as they become available, you should use the optimum clearances.

Hole in Wall
Note 1: The boundary marked with a B shows the cable access hole for all cables.

Minimum Clearance

1571 mm (61.9 in.) 1431 mm (56.3 in.)


D

Standard, Advert or Open Advert Collar Short Sleeve 203 mm (8.0 in.) 384 mm (15.1 in.) Standard Sleeve 330 mm (13.0 in.) 504 mm (19.8 in.)

ADA Collar Short Sleeve 178 mm (7.0 in.) 330 mm (13.0 in.) Standard Sleeve 292 mm (11.5 in.) 450 mm (17.7 in.)

Barometric Pressure
Operating and transit limits Equivalent altitude 105 kPa (15.2 lb. F/in.) to 70 kPa (10.2 lb. F/in.) Up to a maximum of 3000 m (9842.52 ft).

222 mm (8.7 in.)

1209 mm (47.6 in.)

211 mm (8.3 in.) 326 mm (12.8 in.)

See Note 2 See Note 1 1000 mm (39.4 in.)

Optimum Clearance
1780 mm (70.0 in.)

HOLE IN THE WALL DIMENSIONS

* Only applicable to installations of


20 mm* (0.8 in.)

ADA collar with a standard sleeve.

170 mm* (6.7 in.)

36 mm* (1.4 in.) Hole in Wall NOT TO SCALE F

See Note 4
326 mm (12.8 in.)

770 mm (30.3 in.)

525 mm (20.7 in.)

25 mm (1.0 in.)

Optimum Height of No. 5 Key

C A
19 mm (0.7 in.)

B ATM Base Plinth C

460 mm (18.1 in.) 98 mm (3.9 in.)

320 mm (12.6 in.) See Note 3 770 mm (30.3 in.)

550 mm (21.6 in.) 341 mm (13.4 in.)

1000 mm (39.4 in.)

Sidewalk D (Maximum thickness) Lowered Height Installations CAE ADA ADA and ADAAG CSA Parallel Approach Parallel Approach Forward Approach Parallel Approach A B C 882 mm (34.7 in.) 816 mm (32.1 in.) 168 mm (6.6 in.) 1005 mm (39.6 in.) 939 mm (37.0 in.) 291 mm (11.5 in.) 852 mm (33.5 in.) 786 mm (30.9 in.) 138 mm (5.4 in.) 832 mm (32.8 in.) 766 mm (30.2 in.) 118 mm (4.6 in.) Optimum Height Installations New Hole Existing 5886 Hole

View from Inside Building New Hole in the Wall (Lowered & Optimum Heights) It is the responsibility of the owning institution to ensure that the heights from the sidewalk level to the facia items comply with any local regulations. Note 1: An Open Advert or ADA collar is recommended at installation. Note 2: The height of the plinth depends upon the difference in height between the sidewalk and the interior floor. If there is no difference, the plinth must have the height that is specified in the table. Optimum Height and Existing 5886 Hole at Lowered Height The existing plinth must be replaced with a new one. Optimum Height The Open Advert collar does not fit through this hole. New Hole at Optimum Height Existing 5886 Hole at Optimum Height Std, Advert or Logo Collar Standard Sleeve 330 mm (13.0 in.) Short Sleeve 203 mm (8.0 in.) ADA Collar Standard Sleeve 292 mm (11.5 in.) Short Sleeve 178 mm (7.0 in.)

460 mm (18.1 in.)

460 mm (18.1 in.)

90 mm (3.5 in.)

Side clearance Rear clearance BNA on RH side clearance

750 mm (29.5 in.)


B

1082 mm (42.6 in.) 1026 mm (40.4 in.) 368 mm (14.5 in.) 372 mm (14.6 in.)

Standard, Advert or Open Advert Collar Short Sleeve A 2264 mm (89.13 in.) B C 203 mm (8.0 in.) 2042 mm (80.4 in.) Standard Sleeve 2377 mm (93.6 in.) 330 mm (13.0 in.) 2155 mm (84.8 in.)

ADA Collar Short Sleeve 2210 mm (87.0 in.) 178 mm (7.0 in.) 1988 mm (78.3 in.) Standard Sleeve 2323 mm (91.5 in.) 292 mm (11.5 in.) 2101 mm (82.7 in.) Standard, Advert or Open Advert Collar Short Sleeve Standard Sleeve ADA Collar Short Sleeve Standard Sleeve
750 mm (29.5 in.)

New Hole at Lowered Height Open Advert Collar Standard Sleeve D E F 330 mm (13.0 in.) Short Sleeve 203 mm (8.0 in.) ADA Collar Standard Sleeve 292 mm (11.5 in.) Short Sleeve 178 mm (7.0 in.)

Existing 5886 Hole at Lowered Height Open Advert Collar Standard Sleeve 330 mm (13.0 in.) Short Sleeve 203 mm (8.0 in.) ADA Collar Standard Sleeve 292 mm (11.5 in.) Short Sleeve 178 mm (7.0 in.) 625 mm (24.6 in.) 518 mm (20.4 in.)

Std, Advert or Logo Collar Standard Sleeve 330 mm (13.0 in.) Short Sleeve 203 mm (8.0 in.)

ADA Collar Standard Sleeve 292 mm (11.5 in.) Short Sleeve 178 mm (7.0 in.)

625 mm (24.6 in.) 744 mm (29.3 in.) 534 mm (21.0 in.)

610 mm (24.0 in.) 718 mm (28.3 in.)

625 mm (24.6 in.) 534 mm (21.0 in.)

610 mm (24.0 in.) 518 mm (20.4 in.)

Note 1: Side clearance is required for servicing the GBNA or GBRU cash acceptor (notes inserted into the module long edge first). It is not required for the BNA2 cash acceptor (notes inserted into the module short edge first). Note 2: Rear clearance should be used when upgrading to any cash acceptor. However, if this space is not available then upgrade time will increase by approximately four hours. A Note 3: When replacing a 5886 with a SelfServ 34, 35 mm (1.4 in.) extra space is gained on the right hand side because the SelfServ 34 is smaller. B Note 4: If a BNA is to be installed on the right hand side of the ATM then the extra clearance marked on the illustration is required.

2368 mm (93.2 in.) 2481 mm (97.7 in.) 2314 mm (91.1 in.) 2427 mm (95.6 in.) 203 mm (8.0 in.) 330 mm (13.0 in.) 178 mm (7.0 in.) 292 mm (11.5 in.)