Sei sulla pagina 1di 19

Table 1 RNC Command MOD RNCBASIC (Modifying PLMN)

Parameters to be analyzed and adjusted in the access procedure MML Para mete r ID RncId RNC ID Value range: 0~4095 Physical unit: None Meaning: It is the unique identifier of an RNC. Recommended value: None Value range: 0~999 Physical unit: None Meaning: Mobile country code of RNC Recommended value: None Value range: 0~999 or 0~99 Physical unit: None Meaning: Mobile network code of RNC Recommended value: None Value range: CS_DOMAIN(CS domain), PS_DOMAIN (PS domain) Physical unit: None Meaning: It specifies the CN type Recommended value: None Value range: 0~255 Physical unit: 6min Meaning: This parameter indicates the timer length for periodical update. Periodical update is implemented by the MS through location update. The value of 0 indicates period update is not adopted. Only when the CN domain ID is CS_DOMAIN will this parameter be valid. Recommended value: 1 Value range: NOT_ALLOWED, ALLOWED Physical unit: None Meaning: This parameter indicates whether to allow attach or detach, NOT_ALLOWED indicates MS cannot apply IMSI attach and detach procedure, ALLOWED indicates the MS can apply the IMSI attach and detach procedure. This parameter is valid only when CN domain ID is set to CS_DOMAIN. Recommended value: ALLOWED Paramet er name Parameter description

Mcc

Mobile country code Mobile network code

Mnc

MOD CNDOMAIN (Modifying period timer mode) T3212 and network running Cell updating period CNDom ainId CN domain ID

ATT

Attach/det ach allowance indication

NMO

Network maintenan ce mode

DRX Cycle Length Coef SET IDLEMODETIME R (Set the timer in idle mode) T300

Discontinu ous cycle length coefficient

Timer T300

N300

Constant 300

T312

Timer T312

Value range: MODE1, MODE2 Physical unit: None Meaning: This parameter indicates the operation network mode. It is to be set according to the actual configurations of the network. It is to be set to MODE1 if Gs interface exists between SGSN and MSC/VLR, and it is to be set to MODE2 if Gs interface does not exist between SGSN and MSC/VLR. Recommended value: None Value range: 6~9 Physical unit: None Meaning: This parameter is used by the UE to calculate the length of the DRX cycle length of the CN domain. Recommended value: 8 Value range: D100, D200, D400, D600, D800, D1000, D1200, D1400, D1600, D1800, D2000, D3000, D4000, D6000, D8000 Physical value range: 100, 200, 400, 600, 800, 1000, 1200, 1400, 1600, 1800, 2000, 3000, 4000, 6000, 8000 Physical unit: ms Meaning: The UE starts the timer T300 after transmitting the RRC CONNECTION REQUEST message, and this timer after receiving the RRC CONNECTION SETUP message. Once the timer expires, and if V300=<N300, the UE will retransmit RRC CONNECTION REQUEST; otherwise, it will enter idle mode. The default value is 1000. Recommended value: D3000 Value range: 0~7 Physical unit: None Meaning: This parameter indicates the maximum times of retransmission of the RRC CONNECTION REQUEST message, with 3 by default. Recommended value: 3 Value range: 1~15 Physical unit: s Meaning: The UE starts the timer T312 when it starts to set up DCH, and stops this timer when it detects N312 continuous synchronization indications from L1. Once the timer expires, it indicates physical channel setup failure. The default value is 1. Recommended value: 1

N312

Constant 312

SET IDLEMODETIME R (Setting timer the in T301 Timer T301

connected mode)

N301

Constant 301

T302

Timer T302

N302

Constant 302

Value range: D1, D50, D100, D200, D400, D600, D800, D1000 Physical value range: 1, 50, 100, 200, 400, 600, 800, 1000 Physical unit: None Meaning: This parameter indicates the maximum times of continuous synchronization indication from L1. The default value is 1. Recommended value: D1 Value range: D100, D200, D400, D600, D800, D1000, D1200, D1400, D1600, D1800, D2000, D3000, D4000, D6000, D8000 Physical value range: 100, 200, 400, 600, 800, 1000, 1200, 1400, 1600, 1800, 2000, 3000, 4000, 6000, 8000 Physical unit: ms Meaning: This timer is invalid in the R99 protocol. It is a reserved timer. The default value is 2000. Recommended value: None Value range: 0~7 Physical unit: None Meaning: The default value is 2. Recommended value: None Value range: D100, D200, D400, D600, D800, D1000, D1200, D1400, D1600, D1800, D2000, D3000, D4000, D6000, D8000 Physical value range: 100, 200, 400, 600, 800, 1000, 1200, 1400, 1600, 1800, 2000, 3000, 4000, 6000, 8000 Physical unit: ms Meaning: The UE starts the timer T302 after transmitting the CELL UPDATE/URA UPDATE message, and stops this timer after receiving the CELL UPDATE CONFIRM/URA UPDATE CONFIRM message. Once the timer expires, and if V302<=N302, the UE will retransmits CELL UPDATE/URA UPDATE; otherwise, it enters idle mode. The default value is 40000. Recommended value: D2000 Value range: 0~7 Physical unit: None Meaning: It refers to the maximum times of retransmission of the CELL UPDATE/URA UPDATE message. The default value is 3. Recommended value: 3

T304

Timer T304

N304

Constant 304

T305

Timer T305

T307

Timer T307

Value range: D100, D200, D400, D1000, D2000 Physical value range: 100, 200, 400, 1000, 2000 Physical unit: ms Meaning: The UE starts the timer T304 after transmitting the UE CAPABILIRY INFORMATION message, and stops after the receiving the UE CAPABILITY INFORMATION CONFIRM message. Once the timer expires, and if V304<=N304, the UE will retransmits UE CAPABILIRY INFORMATION; otherwise, it will initialize the cell updating procedure. The default value is 2000. Recommended value: D2000 Value range: 0~7 Physical unit: None Meaning: It refers to the maximum times of retransmission of the UE CAPABILIRY INFORMATION message. The default value is 2. Recommended value: 3 Value range: INFINITY, D5, D10, D30, D60, D120, D360, D720 Physical value range: infinity, 5, 10, 30, 60, 120, 360, 720 Physical unit: min Meaning: The UE starts the timer T305 after entering the CELL_FACH, URA_PCH or CELL_PCH state and transmitting the CELL UPDATE CONFIRM/URA UPDATE CONFIRM message. The UE stops this timer after entering other state. Once the timer expires, if the timer T307 is not initiated and the UE detects it is in the service area, the UE will transmit CELL UPDATE. Otherwise, if the timer T307 is not initiated, it will be initiated. The value of Infinity indicates no update The default value is 30. Recommended value: D10 Value range: D5, D10, D15, D20, D30, D40, D50 Physical value range: 5, 10, 15, 20, 30, 40, 50 Physical unit: s Meaning: The UE starts the timer T307 when the timer T305 expires and the UE detects it is out of the service area, and stops this timer when the UE detects it enters the severing area again. Once the timer expires, the UE enters idle mode. The default value is 30. Recommended value: None

T308

Timer T308

N308

ConstantN 308

T309

Timer T309

T310

Timer T310

N310

Constant 310

Value range: D40, D80, D160, D320 Physical value range: 40, 80, 160, 320 Physical unit: ms Meaning: The UE starts the timer T308 after the transmitting the RRC CONNECTION RELEASE COMPLETE message. Once the timer expires, and if V308<=N308, the UE transmits the RRC CONNECTION RELEASE COMPLETE message; otherwise, it enters idle mode. The default value is 160. Recommended value: D160 Value range: 1~7 Physical unit: None Meaning: It refers to the maximum times of retransmission of the RRC CONNECTION RELEASE COMPLETE message. Recommended value: 1 Value range: 1~8 Physical unit: s Meaning: The UE starts the timer T309 after selecting a cell belonging to other radio access system in the connection mode or after receiving the CELL CHANGE ORDER FROM UTRAN message. The UE stops this timer after setting up connection in a new cell successfully. Once the timer expires, the UE will keep connecting with the UTRAN. The default value is 5. Recommended value: 1 Value range: D40, D80, D120, D160, D200, D240, D280, D320 Physical value range: 40, 80, 120, 160, 200, 240, 280, 320 Physical unit: ms Meaning: The UE starts timer T310 after transmitting the PUSCH CAPACITY REQUEST message, and stops after the UE receives the PHYSICAL SHARED CHANNEL ALLOCATION message. Once the timer expires, and if V310<=N310, the UE will transmit the PUSCH CAPACITY REQUEST message; otherwise, this procedure will be ended. The default value is 160. Recommended value: None Value range: 0~7 Physical unit: None Meaning: It refers to the maximum timers of retransmission of the PUSCH CAPACITY REQUEST message. The default value is 4. Recommended value: None

T311

Timer T311

T312

Timer T312

N312

Constant 312

T313

Timer T313

Value range: D250, D500, D750, D1000, D1250, D1500, D1750, D2000 Physical value range: 250, 500, 750, 1000, 1250, 1500, 1750, 2000 Physical unit: ms Meaning: The UE starts the timer T311 after receiving the PHYSICAL SHARED CHANNEL ALLOCATION message, and the item of PUSCH allocation is set to PUSCH allocation pending. The UE stops this timer after receiving the PHYSICAL SHARED CHANNEL ALLOCATION message, and the item of PUSCH allocation is set to PUSCH allocation assignment. Once the timer expires, the UE re-initiates the PUSCH capability request procedure. The default value is 2000. Recommended value: None Value range: 0~15 Physical unit: s Meaning: The timer T312 is initiated after the UE starts setting up the DCH, and it is stopped after the UE detects N312 continuous in-sync indications on L1. Once the timer expires, it indicates physical channel setup failure. The default value is 1. Recommended value: 1 Value range: D1, D50, D100, D200, D400, D600, D800, D1000) Physical value range: 1, 50, 100, 200, 400, 600, 800, 1000 Physical unit: None Meaning: It refers to the maximum number of continuous in-sync indications received from L1. The default value is 1. Recommended value: D1 Value range: 0~15 Physical unit: s Meaning: The UE starts the timer T313 after detecting N313 continuous out-of-sync indications on L1, and stops this timer after detecting N315 continuous in-sync indications on L1. Once the timer expires, it indicates physical channel setup failure. The default value is 3. Recommended value: 3

N313

Constant 313

T314

Timer T314

Value range: D1, D2, D4, D10, D20, D50, D100, D200 Physical value range: 1, 2, 4, 10, 20, 50, 100, 200 Physical unit: None Meaning: It refers to the maximum number of continuous out-of-sync indications received from L1. The default value is 20. Recommended value: D50 Value range: D0, D2, D4, D6, D8, D12, D16, D20 Physical value range: 0, 2, 4, 6, 8, 12, 16, 20 Physical unit: s Meaning: The UE starts the timer T314 when the radio link failure judging criteria are met and the radio bearer associated with the timer T314 exists, and stops this timer after the cell updating procedure is completed. The default value is 12. The UE starts the timer T314 (or T315) and the CELL UPDATE signalling is transmitted when the user in the CELL_DCH state encounters radio link connection failure. Before the timer T314 (or T315) expires, if the radio link reconfiguration by the CELL UPDATE CONFIRM message is not successful, the CELL UPDATE signalling can be retransmitted to perform reconfiguration (related to T302 and N302) of the radio link, so as to offer a chance for radio link reconfiguration. For this, set T314 to a value greater than T302N302. After T314 expires, the service RB corresponding to the timer will be deleted. Recommended value: D0

T315

Timer T315

N315

Constant 315

Value range: D0, D10, D30, D60, D180, D600, D1200, D1800 Physical value range: 0, 10, 30, 60, 180, 600, 1200, 1800 Physical unit: s Meaning: The UE starts the timer T315 when the radio link failure judging criteria are met and the radio bearer associated with the timer T315 exists, and stops this timer after the cell updating procedure is completed. The default value is 180. The UE starts the timer T315 (or T314) and the CELL UPDATE signalling is transmitted when the user in the CELL_DCH state encounters radio link connection failure. Before the timer T315 (or T314) expires, if the radio link reconfiguration by the CELL UPDATE CONFIRM message is not successful, the CELL UPDATE signalling can be retransmitted to perform reconfiguration (related to T302 and N302) of the radio link, so as to offer a chance for radio link reconfiguration. For this, set T314 to a value greater than T302N302. After T315 expires, the service RB corresponding to the timer will be deleted. Recommended value: D0 Value range: D1, D50, D100, D200, D400, D600, D800, D1000 Physical value range: 1, 50, 100, 200, 400, 600, 800, 1000 Physical unit: s Meaning: It refers to the maximum number of insync indications from L1 during the timing period of the timer T313. The default value is 1. Recommended value: D1

T316

Timer T316

T317

Timer T317

MOD CELLFACHMRO CCA (Modifying the cell FACH measurement occasion information) InterFre qFDD MeasInd Interfrequency FDD measurem ent indication CellID Cell ID

Value range: D0, D10, D20, D30, D40, D50, INFINITY Physical value range: 0, 10, 20, 30, 40, 50, infinity Physical unit: s Meaning: The UE starts the timer T316 when it is in the URA_PCH or CELL_PCH state and detects it is out of the service area. The UE stops this timer after it enters the service area again. Once T316 expires, the UE will initiates the cell updating procedure when it detects it is in the service area; otherwise, the UE starts the timer T317. After the UE detects it enters the service area, its state is transited to CELL_FACH, and it will initiates the cell updating procedure. The default value is 30. Recommended value: D30 Value range: D0, D10, D30, D60, D180, D600, D1200, D1800 Physical value range: 0, 10, 30, 60, 180, 600, 1200, 1800 Physical unit: s Meaning: The UE starts the timer T317 when T316 expires or the UE in the CELL_FACH detects it is out of service area. The UE stops this timer after it enters the service area again. Once T317 expires, the UE state is transited to idle. The default value is 180. Recommended value: D30 Value range: 0~268435455 Physical unit: None Meaning: It is the unique identifier of a cell. Recommended value: None Value range: REQUIRE , NOT_REQUIRE Physical unit: None Meaning: It indicates whether this cell requires inter-frequency cell reselection. REQUIRE indicates it require, in this case the parameter of FACH measurement occasion cycle length coefficient is valid for the inter-frequency measurement; NOT_REQUIRE indicates it does not require, in this case the parameter of FACH measurement occasion cycle length coefficient is invalid for the inter-frequency measurement. Recommended value: None

FACHMe asOcca CLC

FACH measurem ent occasion cycle length coefficient

InterRAT MeasInd

Interfrequency system measurem ent indication

MOD CELL (Modifying the CellID Cell ID

basic information data of the cell, including [maximum transmit power of cell], connection [radio MaxTxP ower Maximum transmit power of the cell

Value range: 1~12 Physical unit: None Meaning: It indicates the time when the UE in the CELL_FACH state can enter the interfrequency measurement. The parameter value range is (1-5). The bigger the value, the timer spent for inter-frequency cell measurement will be longer. When the inter-frequency FDD measurement indication is REQUIRE or the inter-frequency system measurement indication is REQUIRE TRUE, this parameter must be mandatory. Recommended value: 4 Value range: REQUIRE, NOT_REQUIRE Physical unit: None Meaning: It indicates whether this cell requires inter-frequency cell reselection. REQUIRE indicates it requires, in this case the parameter of FACH measurement occasion cycle length coefficient is valid for the inter-frequency measurement; NOT_REQUIRE indicates it does not require, in this case the parameter of FACH measurement occasion cycle length coefficient is invalid for the inter-frequency measurement. Recommended value: None Value range: 0~268435455 Physical unit: None Meaning: It is the unique identifier of a cell. Recommended value: None Value range: 0~500 Physical value range: 0~50, with the step length of 0.1 Physical unit: dBm Meaning: It specifies the sum of the maximum transmit power of all the downlink channels in the cell at the same time. It is set according to the network planning. Recommended value: 430

failure [number continuous

time], of inNInsyncI nd Number of continuous in-sync indications

sync indications], [number of outof-sync indications] ) as well the as the transmit power of downlink common channels (primary synchronization channel, secondary synchronization channel, primary common and cell. pilot TRlFailur e physical channel broadcast channel) in the NOutsy ncInd

Number of continuous out-of-sync indications

Duration of radio link failure timer

Value range: 1~256 Physical unit: None Meaning: It specifies the number of continuous in-sync indications to be received in the radio link recovery process triggered by NodeB. The radio link set keeps in the initial state until it receives NInsyncInd continuous in-sync indication from L1. In this case, After the radio link recovery process triggered by NodeB indicates radio link set are synchronized, once the radio link recovery process is triggered, the radio link set will be taken as in the in-sync state. Recommended value: 5 Value range: 1~256 Physical unit: None Meaning: It specifies the number of continuous out-of-sync indications received for starting the Timer TRlFailure. When the radio link set is in the in-sync state, NodeB needs to start the timer TRlFailure after it receives NOutsyncInd continuous out-of-sync indications. The NodeB needs to stop and reset this timer after it receives NInsyncInd continuous in-sync indications. If the timer TRlFailure expires, NodeB will trigger the radio link failure procedure, and indicates the radio link set out-of-sync. Recommended value: 5 Value range: 0~255 Physical value range: 0~25.5, with the step length of 0.1 Physical unit: s Meaning: It specifies the length of the timer TRlFailure. When the radio link set is in the insync state, NodeB needs to start the timer TRlFailure after it receives NOutsyncInd continuous out-of-sync indications. And NodeB should stop and reset this timer after it receives NInsyncInd continuous in-sync indications. If the timer TRlFailure expires, NodeB will trigger the radio link failure procedure and indicates the radio link set out-of-sync. Recommended value: 200

PschPow er

PSCH transmit power

SschPo wer

SSCH transmit power

PcpichP ower

PCPICH transmit power

BchPow er

BCH transmit power

MOD CELLSETUP (This command CellID CellNam e Cell ID Cell name

can modify the basic information

Value range: -350~150 Physical value range: -35~15, with the step length of 0.1 Physical unit: dB Meaning: This parameter indicates the power offset from the transmit power of the primary common pilot channel (PCPICH) in the cell. PSCH transmit power = [PschPower]0.1 + PCPICH transmit power. Recommended value: -50 Value range: -350~150 Physical value range: -35~15, with the step length of 0.1 Physical unit: dB Meaning: This parameter indicates the power offset from the transmit power of the primary common pilot channel (PCPICH) in the cell. SSCH transmit power = [SschPower] 0.1+PCPICH transmit power Recommended value: -50 Value range: -100~500 Physical value range: -10~50, with the step length of 0.1 Physical unit: dBm Meaning: This parameter defines the power offset from the transmit power of the PCPICH in the cell. This parameter needs to be set based on the actual system environment, for example, cell coverage range (radius) and geographic environment. Recommended value: 330 Value range: -350~150 Physical value range: -35~15, with the step length of 0.1 Physical unit: dB Meaning: It specifies the power offset of the transmit power of the PCPICH in the corresponding cell. BCH transmit power = [BchPower] 0.1 + PCPICH transmit power. Recommended value: -20 Value range: 0 ~268435455 Physical unit: None Meaning: It is the unique identifier of a cell. Recommended value: None Value range: 250 characters Physical unit: None Meaning: It is the unique name of a cell Recommended value: None

of a cell, such as cell name, uplink frequency, downlink frequency, node synchronization switch and primary downlink scrambling code, as required.) UARFCN Downlin k Downlink frequency UARFCN Uplink Uplink frequency

TCell

Time deviation

DlTpcPa ttern01 Count

Downlink power control mode 1

PowerR aiseLimi t DlPower Average Window Size

Power raise limit

Downlink power average window size

Value range: 0~16383 Physical value range: 0.0~3276.6 Physical unit: MHz Meaning: It specifies the uplink frequency of the cell. Recommended value: None Value range: 0~16383 Physical value range: 0.0~3276.6 Physical unit: MHz Meaning: It specifies the downlink frequency of the cell. Recommended value: None Value range: CHIP0, CHIP256, CHIP512, CHIP768, CHIP1024, CHIP1280, CHIP1536, CHIP1792, CHIP2048, CHIP2304 Physical value range: 0, 256, 512, 768, 1024, 1280, 1536, 1792, 2048, 2304 Physical unit: chip Meaning: This value is used to define the time deviation from BFN, synchronization channel (SCH) in the cell, common pilot channel (CPICH) and downlink scrambling code Recommended value: None Value range: 0~30 Physical unit: None Meaning: It determines the DL TPC mode before the uplink synchronization of the first radio link set is completed. Recommended value: 10 Value range: 0~10 Physical unit: dB Meaning: This parameter indicates the raise limit of downlink transmit power within a specific period (defined by DlPowerAverageWindowSize). Recommended value: 10 Value range: 1~60 Physical unit: slot Meaning: UTRAN calculates the raise of downlink transmit power within the period defined by this parameter to check whether the power raise limit is exceeded. If the limit is exceeded, the power will not be adjusted even the power raise command is received. Recommended value: 20

NodeSy nSwitch

Node synchroniz ation switch Primary downlink scrambling code SSDT support indication

PScram bCode

SupSSD T

STTDInd

STTD indication of cell

TxDiver sityMod e

Transmit diversity mode

TxDiver sityInd

Transmit diversity indication

LoCell

Local cell ID

ClosedL oopTim eAdjust Mode

Closed loop time adjusting mode

Value range: ON, OFF Physical unit: None Meaning: It indicates whether to transmit the node synchronization message to NodeB in the cell creation procedure. Recommended value: None Value range: 0~511 Physical unit: None Meaning: It specifies the primary scrambling code sequence in the cell. Recommended value: None Value range: TRUE, FALSE Physical unit: None Meaning: It specifies whether to support location selection diversity (SSDT). Recommended value: FALSE Value range: TRUE, FALSE Physical unit: None Meaning: It specifies whether to support space time transmit diversity (SSDT). Recommended value: None Value range: NONE, STTD, CLOSED_LOOP_MODE1, CLOSED_LOOP_MODE2 Physical unit: None Meaning: It indicates whether to configure STTD open loop transmit diversity or closed loop transmit diversity, or not to configure transmit diversity. If closed loop transmit diversity is to be configured, it is necessary to select the mode to be used. Recommended value: None Value range: TRUE, FALSE Physical unit: None Meaning: It indicates whether to activate transmit diversity configuration. Recommended value: None Value range: 0~268435455 Physical unit: None Meaning: Local cell ID, corresponding to the logical cell one by one. It represents the resource of NodeB. Recommended value: None Value range: OFFSET1, OFFSET2 Physical unit: None Meaning: It indicates the time when the phase/amplitude adjustment is to be executed when the closed loop transmit diversity is performed on the DPCH. Recommended value: None

MOD CELLSETUP (Modifying other information of a cell, incuding service indication (ServiceInd), location code (RAC), area (SAC)). RAC Routing area code area (LAC), service code LAC Location area domain code ServiceI nd CN domain indication CellID Cell ID

route area code

SAC

Service area code

MOD PCPICHPWR

CellID

Cell ID

Value range: 0~268435455 Physical unit: None Meaning: The unique identifier of a cell. Recommended value: None Value range: SUPPORT_CS, SUPPORT_PS, SUPPORT_CS_AND_PS Physical value range: 0,1,2 Physical unit: None Meaning: It specifies the CN domain service this cell can support. Recommended value: SUPPORT_CS_AND_PS Value range: 0x0000~0xFFFF (Except 0x0000 and 0xFFFE Physical unit: None Meaning: It specifies a location area for the PLMN of the GSM-MAP type. It is defined by the operator. Recommended value: None Value range: 0x00~0xFF Physical unit: None Meaning: It specifies a routing area code within a location area code. It is defined by the operator. Recommended value: None Value range: 0x0000~0xFFFF Physical unit: None Meaning: It constitutes service area ID (SAI) together with PLMN-Id and LAC. The service area ID is used to define an area composed of one or more cells belonging to one location area. This area is called as service area, used for indicating the location of the UE for the CN. SAC is defined by the operator. Recommended value: None Value range: 0~268435455 Physical unit: None Meaning: It is the unique identifier of a cell. Recommended value: None

(Modifying power information the common channel

the of pilot

primary MaxPCPI CHPowe r Maximum PCPICH transmit power

(PCPICH) in the cell.)

MinPCPI CHPowe r

Minimum PCPICH transmit power

MOD CELLACCESSS TRICT (Modifying cell restriction configuration information, including cell the CellRese rvedforo perator use Indication of cell reserved for operator use CellID Cell ID

access

Value range: -100~500 Physical value range: -10~50, with the step length of 0.1 Physical unit: dBm Meaning: It specifies the maximum transmit power of the PCPICH in the cell. It should be set based on the actual system environment, such as cell coverage range (radius) and geographic environment. It is affected by the total power of the cell. When the maximum transmit power of the PCPICH is too large, the cell capacity will be decreased. Increasing the power of the pilot channel under the condition of ensuring a certain soft handover area proportion will not help to improve the performance of downlink coverage. Recommended value: None Value range: -100~500 Physical value range: -10~50, with the step length of 0.1 Physical unit: dBm Meaning: It indicates the minimum transmit power of the PCPICH in the cell. It should be set based on the actual system environment, such as cell coverage range (radius) and geographic environment. When the maximum transmit power of the PCPICH is too small, the cell capacity will be affected. This parameter should be set under the condition of ensuring a certain soft handover area proportion or ensuring no coverage void. Recommended value: None Value range: 0~268435455 Physical unit: None Meaning: It is the unique identifier of a cell. Recommended value: None Value range: RESERVED, NOT_RESERVED Physical unit: None Meaning: It indicates whether the cell is reserved for the operator. If the current cell is in the NOT_BARRED (access allowed) state, and its indication is RESERVED for operator use, the UEs assigned toes 11 and 15 in the local PLMN can select or reselect this cell; while the UEs assigned toes of 0 to 9 and 12 and 14 cannot. Recommended value: NOT_RESERVED

state

and

cell as CellRese rvationE xtension Indication of cell reservation extension

reservation information control information) Where, by setting the access control information, the operator can prevent access channel overload in the critical condition. The SIM/USIMs of all UEs have been assigned to one of access classes 0 to 9. In addition, the IsAccess Class0B arred IsAccess Class15 Barred CellBarr ed well as access

Indication of barring Access classes 0 15 Indication of cell barred

Value range: RESERVED, NOT_RESERVED Physical unit: None Meaning: It indicates whether this cell is reserved for expansion. If current cell is in the NOT_BARRED (allowed to access) state, and its indication is NOT_RESERVED for operator use but RESERVED for expansion, the UEs will be barred from this cell. Recommended value: NOT_RESERVED Value range: BARRED, NOT_BARRED Physical unit: None Meaning: It indicates whether the UE assigned to 0 is allowed to initiate access. The UE judges whether it belongs to this class from SIM/USIM. Recommended value: NOT_BARRED (allowed to access) Value range: BARRED, NOT_BARRED Physical unit: None Meaning: When the cell is in the BARRED state, it indicates it cannot be selected or reselected by the UE, even if for the emergency call service. This parameter is in the switch type. Recommended value: NOT_BARRED (allowed to access)

SIM/USIM storage information of the UEs may be assigned with one or more special access classes (access classes 11 to 15). The UEs of these classes are the special uses with high quality, as described below: Access class 15 PLMN Staff Access class 14 Emergency Services Access class 13 Public Utilities Access class 12 Security Services Access class 11 For PLMN Use Different from access classes 0 to 9 and access classes 11 to 15, the control of information

IntraFre qResele ctionId

Intrafrequency cell reselection indication

Value range: ALLOWED, NOT_ALLOWED Physical unit: None Meaning: This parameter is valid when the CellBarred is set to BARRED. When the cell state is barred, if this parameter is set to ALLOWED, the UE can select another intrafrequency cell when the cell selection/reselection condition is met; if this parameter is set to NOT_ALLOWED, the UE cannot reselect another intra-frequency cell. For emergency call, this indication can be ignored. Recommended value: None

access class 10 is notified to the UE through air interface signals, for indicating whether the UEs

Potrebbero piacerti anche