Sei sulla pagina 1di 164

GRUNDFOS DATA BOOKLET

TP, TPD, TPE, TPED


In-line circulator pumps
50 Hz

Contents

Pump data
Introduction
Type key
Codes for shaft seal

TP Series 400 pumps


4
5
5

Performance range
Performance range, 2-pole, PN 6/10/16
Performance range, 4-pole, PN 6/10/16
Performance range, 6-pole, PN 16
Performance range, 2-pole, PN 25
Performance range, 4-pole, PN 25

6
7
8
9
10

Product range
Product range, 2-pole, PN 6/10/16
Product range, 4-pole, PN 6/10/16
Product range, 6-pole, PN 16
Product range, 2-pole, PN 25
Product range, 4-pole, PN 25

11
13
15
16
17

Operating conditions
Pressure conditions
Ambient temperature

18
18

19
19
20

TP Series 100 and 200 pumps


Technical data
Construction
Materials
Mechanical shaft seal
Connections
Control
Product features and benefits

22
22
22
23
23
23
23

TP Series 300 pumps


Technical data
Construction
Materials
Mechanical shaft seal
Connections
Control
Product features and benefits

26
26
26
27
27
27

TPE Series 2000 pumps


Technical data
Construction
Applications
Operating modes of twin-head pumps
Control options

28
28
28
29
29

TPE Series 1000 pumps


Technical data
Construction
Applications
Operating modes of twin-head pumps
Control options

30
30
30
31
31

Communication
Communication with TPE, TPED pumps
Affinity equations

Pumped liquids
Pumped liquids
Liquid temperature
List of pumped liquids

Technical data
Construction
Materials
Mechanical shaft seal
Connections
Product features and benefits

32
33

Motors for TP pumps


Motors
Motor protection
Electrical data, standard motors
Electrical data, motors with built-in frequency
converter

34
34
35
36

Installation
Mechanical installation
Electrical installation

37
40

Flanges for TP pumps


24
24
24
24
25
25
25

Flange dimensions

42

Curve charts
How to read the curve charts
Curve conditions

43
44

Contents

Performance curves,
technical data
TP, TPD, TPE, TPED, 2-pole, PN 6/10/16
TP, TPD, TPE, TPED, 4-pole, PN 6/10/16
TP, TPD, TPE, TPED, 6-pole, PN 16
TP, 2-pole, PN 25
TP, 4-pole, PN 25

46
68
92
96
100

Weights and shipping volume


TP, TPD, TPE, TPED, 2-pole, PN 6/10/16
TP, TPD, TPE, TPED, 4-pole, PN 6/10/16
TP, TPD, 6-pole, PN 6/10/16
TP, 2-pole, PN 25
TP, 4-pole, PN 25

114
116
117
117
118

Accessories
Unions and valves
Counter flanges
Base plates
Blanking flanges
Insulating kits
Sensors
Potentiometer
R100
G10-LON interface
EMC-filter

119
120
124
126
130
131
132
132
132
132

Minimum inlet pressure - NPSH


TP, TPD 2-pole, PN 6/10/16
TP, TPD 4-pole, PN 6/10/16
TP, TPD 6-pole, PN 16
TP Series 400, 2-pole, PN 25
TP Series 400, 4-pole, PN 25

134
135
135
136
136

Replacement list
Replacement of LM, LP and CLM pumps

137

Further product documentation


WinCAPS
WebCAPS

161
162

Pump data

Introduction
TP pumps are designed for applications such as
district heating systems
heating systems
air-conditioning systems
district cooling systems
water supply
industrial processes
industrial cooling.
The pumps are available with either standard motors
(TP and TPD) or electronically speed-controlled motors
(TPE and TPED).
The pumps are all single-stage, in-line centrifugal
pumps with standard motor and mechanical shaft seal.
The pumps are of the close-coupled type, i.e. pump and
motor are separate units. Consequently, the pumps are
less sensitive to impurities in the pumped liquid than
similar pumps of the canned rotor type.
The TP range is divided into the following three groups:
TP Series 100, 200, 300 and 400 pumps (uncontrolled standard pumps).
TPE Series 2000 pumps (speed controlled pumps
with factory-fitted pressure sensor).
TPE Series 1000 pumps (speed controlled pumps).

TP, TPD, TPE, TPED

TPE Series 2000 pumps


The main differences between the TP and the TPE
Series 2000 pump range are the motor and the factoryfitted integrated differential-pressure sensor.
The motors of TPE Series 2000 pumps have built-in
frequency converter designed to continuously regulate
the pressure to the flow.
The TPE Series 2000 range is recognized as a pre-set
solution for quick and safe installation.
TPE Series 2000 pumps are based on TP Series 100,
200 and 300 pumps. The pump materials are the same
as those of the TP pump range.
For further information about TPE Series 2000 pumps,
see page 28.

TPE Series 1000 pumps


The difference between the TP and the TPE Series
1000 pump range is the motor. The motors of TPE
Series 1000 pumps have built-in frequency converter.
Via an external signal (from a sensor or a controller),
TPE Series 1000 pumps allow for any configuration and
control method required: constant pressure, constant
temperature or constant flow. TPE Series 1000 pumps
are based on TP Series 100, 200 and 300 pumps. The
pump materials are the same as those of the TP pump
range.

TP Series 100 with union or flange connection

For further information about TPE Series 1000 pumps,


see page 30.

Rp 1 (DN 25) to Rp 1 (DN 32) and motor sizes from


0.12 to 0.25 kW.

Why select a TPE pump?

For further information about TP Series 100 with union


or flange connection, see page 22.

TP Series 200 with flange connection

A TPE pump with electronic, speed-controlled adaptation of performance offers these obvious benefits:
Energy savings
Increased comfort

DN 32 to DN 100 and motor sizes from 0.12 to 2.2 kW.

Control and monitoring of pump performance.

For further information about TP Series 200 with flange


connection, see page 22.

Furthermore, a TPE pump offers


communication with the pump.

TP Series 300 with flange connection


DN 32 to DN 150 and motor sizes from 0.25 to 30 kW.
For further information about TP Series 300 with flange
connection, see page 24.

On request, Grundfos offers TP and TPD pumps with


ATEX-approval.

TP Series 400 with flange connection

All ATEX-approved TP pumps are in accordance with


Council directive 94/9/EC (Group II, category 3).

Grundfos offers the following two TP Series 400


versions:

High-efficiency motors

10 bar version with DN 150 to DN 250 flange and


motor sizes from 30 to 75 kW.

2- and 4-pole TP pumps with motor sizes from 1.1 to 90


kW are fitted with high-efficiency motors (EFF 1). EFF 1
is the highest efficiency class defined by CEMEP.

25 bar version with DN 100 to DN 400 and motor


sizes from 5.5 to 630 kW.
For further information about TP Series 400 pumps, see
page 26.

ATEX-approved TP pumps

Pump data

TP, TPD, TPE, TPED

Type key
Example

TP

65

-120

/2

-S

-A

-F

-A

-AUUE

Pump range
Electronically speed-controlled pump series 1000/2000
Twin-head pump
Nominal diameter of suction and discharge ports (DN)
Maximum head [dm]
Pole number
S

= TPE Series 2000 (with factory-fitted differential pressure sensor)

Code for pump version:


A
= Basic version
I
= PN 6 flange
X
= Special version
Code for pipework connection:
F
= DIN flange
O
= Union
Code for materials:
A
= Basic version
Z
= Bronze pump housing and motor stool
B
= Bronze impeller
Code for shaft seal
(incl. other plastic and rubber components in the pump except the neck ring)

Codes for shaft seal


Example

Grundfos type designation


A = O-ring seal with fixed seal driver
B = Rubber bellows seal
D = O-ring seal, balanced
G = Bellows seal with reduced seal faces
R = O-ring seal with reduced seal faces
Material of rotating face
A = Carbon, antimony-impregnated
B = Carbon, synthetic resin-impregnated
Q = Silicon carbide
U = Tungsten carbide
Material of stationary seat
B = Carbon, synthetic resin-impregnated
Q = Silicon carbide
U = Tungsten carbide
Material of secondary seal
E = EPDM
P = NBR rubber
V = FKM

80

60

50

40

30

20

800

600

500

400

300

200

80

60

50

40

30

20

40-270

25-50 R

25-90 R

32-120

32-150

32-180

32-230

40-230

32-320

32-380

32-460

32-580

TP(D), TPE(D)

PN 6/10/16, 2-pole, 50 Hz

32-50 R

40-50

32
-6
0

40-90

50-180

50-160

50-190

50-60

15

30
50

65-

10

80-240

-36 65
0 -340

65-4

50-440

50-570
0

80-250

65
-55

80-

30

65
-6
0

80-120

80-330

10

20

30

80 100

100-120

40 50 60

65-120

65-180

80-140

80
-5 7
0
520

80-700

65-720

65-460
80-400

30

6566

65-9

260
10
05024
240 6
0
5-2
10
30 80 -210
020
65
0
-19
10
0
016
80-180
0

40360

50-4

580

-47
0

20

50-120

40

40-

40-30
0
40-2
40

50-290

50-710

50-830

50-900

40-60

40
- 12

10

40-180

40-190

32-200

32-250

R
90
32-

Note: All QH-curves apply to single-head pumps. For further information about curve conditions, see page 44.
The hatched area shows the performance range of TPE pumps.

TM02 7550 1004

10

100

15

H
[m]

p
[kPa]

12

50

200

Q [m/h]

300 400

5-5
70

40 50 60 70 Q [l/s]

150

10
02

10
031

10
065
10
0-3
0
90
10
036
0

10
0-4
80

125-730

125-810

Performance range
TP, TPD, TPE, TPED
2-pole, PN 6/10/16

Performance range, 2-pole, PN 6/10/16

(See page 46 for performance curves)

40

30

20

400

300

200

80

60

50

40

30

20

10

50-60

15

50-30

100-30

10

40-30

40-60

10

5 6

20

65-30

50-90

30

80-90

80-110
10
011

100-90

12
511
0

30

15
016
0

40 50 60

150

80 100

300 400

200-260

1000

Q [l/s]

Q [m/h]

600

250-280

90
150-3
10

20
03

200-300

2004 30
150
-37
0

-25
0
150
-22
0
150
-20
0

150 200

160

12
5-1
3

125-

12
5 -2
10
-20
0

80 100

20

100-60

40 50 60

80-60

80-70

80-30

65-60

6590

65
-11

10
013
0

70

70
0-

32-30

40-90

40-100

50
-1

50-130

10

32-40

32-60

32-80

32-100

130

80
- 15
0

100-1

1 00

0
13
015

TM02 7551 1004

10

100

40-

65-150
65-130

60

80-170

80240

100
-33
0

125-360

10
-3

501

65-170

65-240

80-270

100-370

125-320

125-250
100-250

100-410

0
25

50-190

50-230

80-340

125-420

0
39
0-

32-120

40-160

TP(D), TPE(D)

PN 6/10/16, 4-pole, 50 Hz

25

15

H
[m]

p
[kPa]

Performance range
TP, TPD, TPE, TPED
4-pole, PN 6/10/16

Performance range, 4-pole, PN 6/10/16

(See page 68 for performance curves)

Note: All QH-curves apply to single-head pumps. For further information about curve conditions, see page 44.
The hatched area shows the performance range of TPE pumps.

Note: All QH-curves apply to single-head pumps. For further information about curve conditions, see page 44.

12

15

20

H
[m]

TM02 8768 0904

30

40

50

60

70

80

90

100

200

p
[kPa]

20

TP(D)

30

10

125-60/6

125-70/6

150-90/6

125-90/6

125-110/6

125-140/6

125-170/6

PN 16, 6-pole, 50 Hz

40

50

60

20

80

100

30

150-60/6

150-110/6

40

150

150-70/6

50

250

Q [l/s]

Q [m/h]

200

Performance range
TP, TPD
6-pole, PN 16

Performance range, 6-pole, PN 16

(See page 92 for performance curves)

30

40

50

60

70

80

90

100

150

200

H
[m]

TM02 6868 1803

300

400

500

600

700

800

900

1000

2000

p
[kPa]

20

30

TP

9 10

40

PN 25, 2-pole, 50 Hz

50

60

20

70 80

100-620

100-700

100-820

100-960

100-1050

100-1180

100-1400

100-1530

100-1680

30

100

40

150

50

60

200

400

70 80 90 100

300

125-580

125-720

125-750

125-1060

125-1
16 0

125-1310

125-15
00

125-1670

600 700

Q [l/s]

Q [m/h]

500

Performance range
TP
2-pole, PN 25

Performance range, 2-pole, PN 25

(See page 96 for performance curves)

10

20

30

40

150

200

300

400 500 600

50 60 70 80 100

0
-20
125
60
0-2
10

80 100

0
37

50 60

TM02 6869 1304

40

0
-42

7 8 9 10

30

0
-2 8

200-260

300-590

300-670

200

300

800 1000

-320

20

-27

50

0
15

150-240

200

10

512

250

100

12
5-1

100-190

0
38
0-

250-270

-6
6

0
-60
250

15

0
20

-31
0

-3
20

-3
5

0
20

1 25
-240

125

15
0

15
0

20
045

100-220

25
0

37
025

20

- 28

5-4
3

200
-56
0

200-620

0
-54
0
250
-49
250

100-270

125

12

0
43
015

100-320

100-380

100-420

150-530

150-650

300-750

400-670

400
- 76
0
400
-720

400 500 600

1500 2000

400-470

800

5000

Q [l/s]

Q [m/h]

3000

0
- 54
10
0 -5
40

200

TP

PN 25, 4-pole, 50 Hz

0
20
1
-5

30

40

50

60

70

H
[m]

0
40

300

400

500

600

700

p
[kPa]

Performance range
TP
4-pole, PN 25

Performance range, 4-pole, PN 25

(See page 100 for performance curves)

Product range

TP, TPD, TPE, TPED


2-pole, PN 6/10/16

Product range, 2-pole, PN 6/10/16

0.12 0.12

0.37

TP 32-90/2 R

z z

0.25 0.25

0.37

TP, TPD 32-60/2

z z

z z z

0.25 0.18

0.37

TP, TPD 32-120/2

z z

z z z

0.25 0.37

0.37

TP, TPD 32-150/2

z z

z z z

0.37 0.37

0.37

TP, TPD 32-180/2

z z

z z z

0.55 0.55

0.55

TP, TPD 32-230/2

z z

z z z

0.75 0.75

0.75

0.75

TP, TPD 32-200/2

z z

z z z

1.1

1.1

1.1

TP, TPD 32-250/2

z z

z z z

1.5

TP, TPD 32-320/2

z z z

2.2

2.2

2.2

TP, TPD 32-380/2

z z z

3.0

3.0

3.0

TP, TPD 32-460/2

z z z

4.0

4.0

4.0

TP, TPD 32-580/2

z z z

5.5

5.5

TP 40-50/2

TP, TPD 40-60/2

z z

TP 40-90/2

TP, TPD 40-120/2

z z

TP 40-180/2

z z

TP, TPD 40-190/2

z z

z z z

z z z

z z

z z z

TP, TPD 40-230/2

z z

TP, TPD 40-270/2

z z

TP, TPD 40-240/2

z z

TP, TPD 40-300/2

z z

TP, TPD 40-360/2

Bronze

Cast iron

Cast iron
EN-GJL-250

z z

PN 25

PN 16

PN 10

PN 6

0.37

TP 32-50 /2 R

DBUE

0.37

0.25 0.25

GQQE

0.12 0.12

BQQE

BAQE

RUUE

AUUE

z z

BUBE

z z

TP Series 400

TP Series 300

TP Series 200

TP 25-90/2 R

TP Series 100

TP 25-50/2 R

3 x 380-415 V

3 x 380-480 V

1 x 220-240 V

Voltage [V]

Stainless steel

3 x 380-415 V/
660-690 YV

Voltage [V]
3 x 220-240 V/
380-415 YV

Impeller

Bronze(1

Nodular cast iron


EN-GJS-400-18

TPE Series 2000

TPE Series 1000

Pump housing

Pump type

Electronically
Standard motor speed-controlled
motor

Materials

1 x 220-230 V/
240 YV

Pressure
stage

Shaft seal

Nodular cast iron


EN-GJS-400-15

Design

P2
P2
P2
P2
P2
P2
[kW] [kW] [kW] [kW] [kW] [kW]

1.5

5.5

0.12 0.12

0.37

0.25 0.25

0.37

0.25 0.25

0.37

0.37 0.37

0.37

0.55 0.55

0.55

0.75 0.75

0.75

0.75

z z z

1.1

1.1

1.1

1.1

z z z

1.5

1.5

z z z

2.2

2.2

2.2

z z z

3.0

3.0

3.0

z z z

4.0

4.0

4.0

TP, TPD 40-470/2

z z z

5.5

5.5

5.5

TP, TPD 40-580/2

z z z

7.5

7.5

TP, TPD 50-60/2

z z

z z z

0.25 0.37

0.37

TP, TPD 50-120/2

z z

z z z

0.55 0.75

0.75

0.75

TP, TPD 50-180/2

z z

z z z

0.75 0.75

0.75

0.75

TP, TPD 50-160/2

z z

z z z

1.1

1.1

1.1

TP, TPD 50-190/2

z z

z z z

1.5

TP, TPD 50-240/2

z z

z z z

2.2

2.2

2.2

TP, TPD 50-290/2

z z

z z z

3.0

3.0

3.0

TP, TPD 50-360/2

z z

z z z

4.0

4.0

4.0

TP, TPD 50-430/2

z z z

5.5

5.5

5.5

TP, TPD 50-440/2

z z z

7.5

7.5

7.5

TP, TPD 50-570/2

z z z

11.0 11.0

11.0

TP, TPD 50-710/2

z z z

15.0 15.0

15.0

TP, TPD 50-830/2

z z z

18.5 18.5

18.5

TP, TPD 50-900/2

z z z

22.0 22.0

TP, TPD 65-60/2

z z

z z z

0.55 0.55

0.55

TP, TPD 65-120/2

z z

z z z

1.1

1.1

1.1

TP, TPD 65-180/2

z z

z z z

1.5

1.5

TP, TPD 65-190/2

z z

z z z

2.2

2.2

2.2

TP, TPD 65-230/2

z z

z z z

3.0

3.0

3.0

TP, TPD 65-260/2

z z

z z z

4.0

4.0

4.0

TP, TPD 65-340/2

z z

z z z

5.5

5.5

5.5

z z z

z z

1.5

7.5

1.5

22.0
1.1
1.5

11

Product range

3 x 380-415 V

3 x 380-480 V

Voltage [V]
1 x 220-240 V

3 x 380-415 V/
660-690 YV

3 x 220-240 V/
380-415 YV

Voltage [V]

Bronze

Nodular cast iron


EN-GJS-400-15

Stainless steel

Bronze(1

Nodular cast iron


EN-GJS-400-18

Cast iron
EN-GJL-250

PN 25

PN 16

PN 10

PN 6

DBUE

GQQE

BQQE

BAQE

RUUE

AUUE

BUBE

TP Series 400

Impeller

P2
P2
P2
P2
P2
P2
[kW] [kW] [kW] [kW] [kW] [kW]

TP, TPD 65-410/2

z z

z z z

7.5

TP, TPD 65-460/2

z z z

11.0 11.0

11.0

TP, TPD 65-550/2

z z z

15.0 15.0

15.0

TP, TPD 65-660/2

z z z

18.5 18.5

18.5

TP, TPD 65-720/2

z z z

22.0 22.0

22.0

z z z

30.0 30.0

TP, TPD 65-930/2


z

z z
z z

z z z

2.2

2.2

2.2

TP, TPD 80-180/2

z z

z z z

3.0

3.0

3.0

TP, TPD 80-210/2

z z

z z z

4.0

4.0

4.0

TP, TPD 80-240/2

z z

z z z

5.5

5.5

5.5

TP, TPD 80-250/2

z z

z z z

7.5

7.5

7.5

TP, TPD 80-330/2

z z

z z z

11.0 11.0

11.0

TP, TPD 80-400/2

z z

z z z

15.0 15.0

15.0

TP, TPD 80-520/2

z z z

18.5 18.5

18.5

TP, TPD 80-570/2

z z z

22.0 22.0

22.0

z z z

30.0 30.0

z z

z z z

z z

7.5

TP, TPD 80-140/2

TP, TPD 100-120/2 z z

z z z

7.5

TP, TPD 80-120/2

TP, TPD 80-700/2

12

TP Series 300

TP Series 200

TP Series 100

TPE Series 2000

TPE Series 1000

Pump housing

Pump type

Electronically
Standard motor speed-controlled
motor

Materials

1 x 220-230 V/
240 YV

Pressure
stage

Shaft seal

Cast iron

Design

TP, TPD, TPE, TPED


2-pole, PN 6/10/16

1.1

1.5

1.5

2.2

2.2

2.2

TP, TPD 100-160/2 z z

z z z

4.0

4.0

4.0

TP, TPD 100-200/2 z z

z z z

5.5

5.5

5.5

TP, TPD 100-240/2 z z

z z z

7.5

7.5

7.5

TP, TPD 100-250/2 z z

z z z

11.0 11.0

11.0

TP, TPD 100-310/2 z z

z z z

15.0 15.0

15.0

TP, TPD 100-360/2 z z

z z z

18.5 18.5

18.5

TP, TPD 100-390/2 z z

z z z

22.0 22.0

22.0

TP, TPD 100-480/2

z z z

30.0 30.0

Standard

(1

Bronze versions are only available as single-head pumps.

Product range

TP, TPD, TPE, TPED


4-pole, PN 6/10/16

Product range, 4-pole, PN 6/10/16

3 x 380-415 V

3 x 380-480 V

1 x 220-240 V

Voltage [V]

0.18 0.25

0.37

TP, TPD 32-80/4

z z

z z z

0.25

0.37

TP, TPD 32-100/4

z z

z z z

0.37

0.37

TP, TPD 32-120/4

z z

z z z

0.55

0.55

TP, TPD 40-30/4

z z

z z z

0.12 0.12

0.37

TP 40-60/4

z z

z z z

0.25 0.25

0.37

TP, TPD 40-90/4

z z

z z z

0.18 0.25

0.37

TP, TPD 40-100/4

z z

z z z

0.55

0.55

TP, TPD 40-130/4

z z

z z z

0.75

0.75

TP, TPD 40-160/4

z z

z z z

1.1

TP, TPD 50-30/4

z z

TP, TPD 50-60/4

z z

TP, TPD 50-90/4

z z

z z z

TP, TPD 50-110/4

z z

z z z

TP, TPD 50-130/4

z z

z z z

TP, TPD 50-160/4

z z

z z z

TP, TPD 50-190/4

z z

z z z

TP, TPD 50-230/4

z z

z z z

TP, TPD 65-30/4

z z

TP, TPD 65-60/4

z z

TP, TPD 65-90/4

z z

z z z

TP, TPD 65-110/4

z z

z z z

1.1

TP, TPD 65-130/4

z z

z z z

1.5

TP, TPD 65-150/4

z z

z z z

2.2

2.2

2.2

TP, TPD 65-170/4

z z

z z z

3.0

3.0

3.0

TP, TPD 65-240/4

z z

z z z

4.0

4.0

TP, TPD 80-30/4

z z

TP, TPD 80-60/4

z z

TP, TPD 80-70/4

z z

z z z

1.1

TP, TPD 80-90/4

z z

z z z

1.5

TP, TPD 80-110/4

z z

z z z

2.2

2.2

2.2

TP, TPD 80-150/4

z z

z z z

3.0

3.0

3.0

TP, TPD 80-170/4

z z

z z z

4.0

4.0

4.0

TP, TPD 80-240/4

z z

z z z

5.5

5.5

TP, TPD 80-270/4

z z

z z z

7.5

7.5

7.5

TP, TPD 80-340/4

z z

z z z

11.0 11.0

11.0

TP, TPD 100-30/4

z z

z z z

z z

0.55 0.55

TP, TPD 100-60/4

z z

z z z

z z

1.1

TP, TPD 100-70/4

z z

z z z

1.5

TP, TPD 100-90/4

z z

z z z

2.2

2.2

2.2

TP, TPD 100-110/4

z z

z z z

3.0

3.0

3.0

TP, TPD 100-130/4 z z

z z z

4.0

4.0

4.0

TP, TPD 100-170/4 z z

z z z

5.5

5.5

TP, TPD 100-200/4 z z

z z z

7.5

7.5

7.5

TP, TPD 100-250/4 z z

z z z

11.0 11.0

11.0

TP, TPD 100-330/4 z z

z z z

15.0 15.0

15.0

TP, TPD 100-370/4 z z

z z z

18.5 18.5

18.5

z z z

z z z

0.37

0.55

0.55

0.75

0.75

1.1

1.5

2.2

2.2

3.0

3.0

z z

z z z

z z

0.75
1.1

0.37 0.37

z z z

0.37

z z z

P2
P2
P2
P2
P2
P2
[kW] [kW] [kW] [kW] [kW] [kW]

0.18 0.25

z z z

Bronze

Cast iron

Cast iron
EN-GJL-250

PN 25

z z z

PN 16

PN 10

z z

PN 6

0.37

TP, TPD 32-60/4

DBUE

0.37

0.18 0.25

GQQE

0.12 0.12

BQQE

BAQE

RUUE

AUUE

z z z

BUBE

z z z

TP Series 400

z z

TP Series 300

z z

TP Series 200

TP, TPD 32-30/4


TP, TPD 32-40/4

TP Series 100

Stainless steel

3 x 380-415 V/
660-690 YV

Voltage [V]
3 x 220-240 V/
380-415 YV

Impeller

Bronze(1

Nodular cast iron


EN-GJS-400-18

TPE Series 2000

TPE Series 1000

Pump housing

Pump type

Electronically
Standard motor speed-controlled
motor

Materials

1 x 220-230 V/
240 YV

Pressure
stage

Shaft seal

Nodular cast iron


EN-GJS-400-15

Design

0.75
1.1
1.5
2.2
3.0

0.25 0.25

0.37

0.55 0.55

0.55

0.75

0.75

0.75
1.1
1.5

4.0

0.37 0.37

0.37

0.75 0.75

0.75

0.75
1.1
1.5

5.5

0.55

1.1

1.1
1.5

5.5

13

Product range

3 x 380-415 V

3 x 380-480 V

Voltage [V]
1 x 220-240 V

3 x 380-415 V/
660-690 YV

3 x 220-240 V/
380-415 YV

Voltage [V]

Bronze

Nodular cast iron


EN-GJS-400-15

Stainless steel

Bronze(1

Nodular cast iron


EN-GJS-400-18

Cast iron
EN-GJL-250

PN 25

PN 16

PN 10

PN 6

DBUE

GQQE

BQQE

BAQE

RUUE

AUUE

BUBE

TP Series 400

TP Series 300

TP Series 200

TP Series 100

TPE Series 2000

Impeller

P2
P2
P2
P2
P2
P2
[kW] [kW] [kW] [kW] [kW] [kW]

TP, TPD 100-410/4 z z

z z z

22.0 22.0

z z

z z z

4.0

4.0

TP, TPD 125-110/4

14

TPE Series 1000

Pump housing

Pump type

Electronically
Standard motor speed-controlled
motor

Materials

1 x 220-230 V/
240 YV

Pressure
stage

Shaft seal

Cast iron

Design

TP, TPD, TPE, TPED


4-pole, PN 6/10/16

22.0
4.0

TP, TPD 125-130/4 z z

z z z

5.5

5.5

TP, TPD 125-160/4 z z

z z z

7.5

7.5

7.5

TP, TPD 125-210/4 z z

z z z

11.0 11.0

11.0

TP, TPD 125-250/4 z z

z z z

15.0 15.0

15.0

TP, TPD 125-320/4 z z

z z z

18.5 18.5

18.5

TP, TPD 125-360/4 z z

z z z

22.0 22.0

22.0

TP, TPD 125-420/4

z z z

30.0 30.0

5.5

TP, TPD 150-130/4 z

z z z

7.5

7.5

7.5

TP, TPD 150-160/4 z

z z z

11.0 11.0

11.0

TP, TPD 150-200/4 z

z z z

15.0 15.0

15.0

TP, TPD 150-220/4 z

z z z

18.5 18.5

18.5

TP, TPD 150-250/4 z

z z z

22.0 22.0

22.0

TP 150-310/4

z z z

30.0 30.0

TP 150-370/4

z z z

37.0

TP 200-260/4

z z z

30.0

TP 200-300/4

z z z

37.0

TP 200-390/4

z z z

45.0

TP 200-430/4

z z z

55.0

TP 250-280/4

z z z

45.0

TP 250-310/4

z z z

55.0

TP 250-390/4

z z z

75.0

Standard

(1

Bronze versions are only available as single-head pumps.

Product range

TP, TPD
6-pole, PN 16

Product range, 6-pole, PN 16

TP, TPD 125-60/6

z z z

1.5

z z z

2.2

2.2

TP, TPD 125-90/6

z z z

3.0

3.0

TP, TPD 125-110/6

z z z

4.0

4.0

TP, TPD 125-140/6

z z z

5.5

5.5

TP, TPD 125-170/6

z z z

7.5

7.5

TP, TPD 150-60/6

z z z

2.2

2.2

TP, TPD 150-70/6

z z z

3.0

3.0

TP, TPD 150-90/6

z z z

4.0

4.0

TP, TPD 150-110/6

z z z

5.5

5.5

Standard

(1

Bronze versions are only available as single-head pumps.

3 x 380-415 V

3 x 380-480 V

P2
P2
P2
P2
P2
P2
[kW] [kW] [kW] [kW] [kW] [kW]

TP, TPD 125-70/6

Voltage [V]
1 x 220-240 V

3 x 380-415 V/
660-690 YV

3 x 220-240 V/
380-415 YV

Voltage [V]

Bronze

Nodular cast iron


EN-GJS-400-15

Impeller

Stainless steel

Bronze(1

Nodular cast iron


EN-GJS-400-18

Cast iron
EN-GJL-250

PN 25

PN 16

PN 10

PN 6

DBUE

GQQE

BQQE

BAQE

RUUE

AUUE

BUBE

TP Series 400

TP Series 300

TP Series 200

TP Series 100

TPE Series 2000

TPE Series 1000

Pump housing

Pump type

Electronically
Standard motor speed-controlled
motor

Materials

1 x 220-230 V/
240 YV

Pressure
stage

Shaft seal

Cast iron

Design

15

Product range

TP
2-pole, PN 25

Product range, 2-pole, PN 25

Bronze

75.0

TP 100-1180/2

90.0

TP 100-1400/2

110.0

TP 100-1530/2

132.0

TP 100-1680/2

160.0

TP 125-580/2

55.0

TP 125-720/2

75.0

TP 125-750/2

90.0

TP 125-1060/2

110.0

TP 125-1160/2

132.0

TP 125-1310/2

160.0

TP 125-1500/2

200.0

TP 125-1670/2

250.0

Standard

3 x 380-415 V

Nodular cast iron


EN- GJS-400-15

75.0

TP 100-1050/2

Cast iron

Stainless steel

Bronze

Cast iron
EN-GJL-250

PN 25

PN 16

PN 10

55.0

TP 100-960/2

PN 6

DBUE

GQQE

BQQE

BAQE

RUUE

AUUE

45.0

TP 100-820/2

BUBE

37.0

TP Series 400

TP Series 300

TP Series 200

TP Series 100

TPE Series 2000

TPE Series 1000

P2
P2
P2
[kW] [kW] [kW]

3 x 380-480 V

Voltage [V]
1 x 220-240 V

Voltage [V]

TP 100-620/2

16

Impeller

Electronically
speed-controlled
motor

TP 100-700/2

Pump type

Nodular cast iron


EN-GJS-400-18

Pump housing

Standard motor

3 x 380-415 V/
660-690 YV

Materials

3 x 220-240 V/
380-415 YV

Pressure
stage

Shaft seal

1 x 220-230 V/
240 YV

Design

P2
P2
P2
[kW] [kW] [kW]

Product range

TP
4-pole, PN 25

Product range, 4-pole, PN 25

P2
[kW

11.0

15.0

TP 100-380/4

18.5

TP 100-420/4

22.0

TP 125-150/4

7.5

TP 125-200/4

11.0

TP 125-240/4

15.0

TP 125-280/4

15.0

TP 125-310/4

18.5

TP 125-370/4

22.0

TP 125-430/4

30.0

TP 150-240/4

18.5

TP 150-270/4

22.0

TP 150-320/4

30.0

TP 150-350/4

37.0

TP 150-430/4

45.0

TP 150-530/4

55.0

TP 150-650/4

75.0

TP 200-270/4

30.0

TP 200-280/4

37.0

TP 200-380/4

45.0

TP 200-420/4

55.0

TP 200-450/4

55.0

TP 200-510/4

75.0

TP 200-560/4

90.0

TP 200-620/4

110.0

TP 250-270/4

45.0

TP 250-320/4

55.0

TP 250-370/4

75.0

TP 250-490/4

90.0

TP 250-540/4

110.0

TP 250-600/4

132.0

TP 250-660/4

160.0

TP 300-590/4

200.0

TP 300-670/4

250.0

TP 300-750/4

315.0

TP 400-470/4

315.0

TP 400-510/4

355.0

TP 400-540/4

400.0

TP 400-670/4

500.0

TP 400-720/4

560.0

TP 400-760/4

630.0

Cast iron

Stainless steel

Bronze

Nodular cast iron


EN-GJS-400-18

Cast iron
EN-GJL-250

PN 25

TP 100-320/4

PN 16

TP 100-270/4

PN 10

11.0

PN 6

DBUE

GQQE

BQQE

BAQE

RUUE

AUUE

7.5

TP 100-260/4

BUBE

TP Series 400

TP Series 300

TP Series 200

TP Series 100

TPE Series 2000

TPE Series 1000

TP 100-220/4

3 x 380-415 V

P2
P2
[kW] [kW

TP 100-190/4

Pump type

3 x 380-480 V

Voltage [V]
1 x 220-240 V

Voltage [V]

Bronze

Impeller

Electronically
speed-controlled
motor

Nodular cast iron


EN- GJS-400-15

Pump housing

Standard motor

3 x 380-415 V/
660-690 YV

Materials

3 x 220-240 V/
380-415 YV

Pressure
stage

Shaft seal

1 x 220-230 V/
240 YV

Design

P2
P2
P2
[kW] [kW] [kW]

5.5

Standard

17

Operating conditions

Pressure conditions

Ambient temperature

System and test pressures

2- and 4-pole motors,


1.1 - 90 kW (EFF 1): Maximum +60C

System pressure

Test pressure

[bar]

[MPa]

[bar]

[MPa]

Other motor sizes:

PN 6

0.6

10

1.0

Note:

PN 10

10

1.0

16

1.6

PN 16

16

1.6

24

2.4

PN 25

25

2.5

38

3.8

When motors installed more than 1000 m above sea


level, the rated motor output will fall due to the low
density and consequent low cooling effect of the air. In
such cases, it may be necessary to use an oversize
motor with a higher output.

Sound pressure level


Single-phase:
Three-phase:

Max. 70 dB(A).
See table below.

Max. sound pressure level [dB(A)] - ISO 3743

P2
[%]
110

Three-phase motors

100

Motor
[kW]

90

2-pole

4-pole

0.12

80

0.18

70

0.25

56

41

60

0.37

56

45

50

0.55

57

42

0.75

56

42

1.1

59

50

1.5

58

50

51

2.2

60

52

56

3.0

59

52

57

4.0

63

54

57

5.5

63

58

57

7.5

68

58

58

11.0

65

60

15.0

65

60

18.5

66

61

22.0

68

61

30.0

69

62

37.0

69

65

45.0

72

65

55.0

74

65

75.0

76

69

90.0

76

69

110.0

78

70

132.0

78

70

160.0

78

70

200.0

78

70

250.0

82

73

315.0

73

355.0

75

400.0

75

500.0

75

560.0

78

630.0

78

6-pole

Note: The gray-shaded areas indicate non-available pumps.

Maximum +40C.

1000

Fig. 1

2250

3500

4750

Relationship between motor output (P2)


and altitude.

TM03 0813 0505

Pressure

18

TP, TPD, TPE, TPED

Pumped liquids

TP, TPD, TPE, TPED

Pumped liquids
Thin, clean, non-aggressive and non-explosive liquids,
not containing solid particles or fibres that may
mechanically or chemically attack the pump, please
see "List of pumped liquids" page 20.
Examples of liquids:
central heating system water (we recommend that
the water meets the requirements of accepted
standards on water quality in heating systems, e.g.
the German standard VDI 2035)
cooling liquids
domestic hot water
industrial liquids
softened water.
If glycol or another antifreeze agent is added to the
pumped liquid, the pump must have a shaft seal of the
type RUUE or GQQE.
The pumping of liquids with densities or kinematic
viscosities higher than those of water can cause
a considerable pressure drop
a drop in the hydraulic performance
a rise in the power consumption.
In these situations, equip the pump with an oversize
motor. If in doubt, contact Grundfos.
If the water contains mineral oils or chemicals, or if
other liquids than water are pumped, the O-rings should
be chosen accordingly.

Liquid temperature
Liquid temperature: 25C to +150C.
Please note that shaft seals operating close to their
maximum temperature will require regular maintenance, i.e. replacement.
Pump type
TP Series 100

Shaft seal

Temperature

BUBE

GQQE

+110C
+90C
25C to +90C
0C to +140C
0C to +90C
25C to +90C
0C to +140C
0C to +90C
25C to +90C
0C to +120C
0C to +90C
25C to +90C

DBUE

0C to

BQQE
GQQE
BUBE

TP Series 200

AUUE
RUUE
BAQE

TP Series 300

BQQE
GQQE
BAQE

TP Series 400,
10 bar version
TP Series 400,
25 bar version

BQQE

0C to

0C to

+150C

From +120 to +150C, max. operating pressure 23 bar.

Depending on the type of cast-iron used and the pump


application, the maximum liquid temperature may be
limited by local regulations and various laws.

19

Pumped liquids

TP, TPD, TPE, TPED

List of pumped liquids


Grundfos TP and TPD pumps are designed for circulation systems with constant flow, TPE and TPED pumps
for systems with variable flow.
Thanks to their design, these pumps can be used in a
wider liquid temperature range than pumps of the
canned rotor type.
A number of typical liquids are listed below.
Other pump versions may be used, but we consider the
ones stated in the list to be the best choices.
The list is intended as a general guide only, and it
cannot replace actual testing of the pumped liquids and
pump materials under specific working conditions. If in
doubt, contact Grundfos.

Legend for notes in the list


A

May contain additives or impurities that may cause shaft


seal problems.

The density and/or viscosity differ from those of water.


Consider this when calculating motor and pump
performance.

However, use the list with some caution as factors such


as

The liquid must be oxygen-free (anaerobic).

Risk of chrystallisation/precipitation in shaft seal.

concentration of the pumped liquid

Insoluble in water.

liquid temperature or

The shaft seal rubber parts must be replaced with FKM


rubber.

pressure

Bronze housing/impeller required.

may affect the chemical resistance of a specific pump


version.

Risk of formation of ice on the standby pump.


(The risk only applies to TP, TPE Series 200 pumps).

Pumped liquids

Notes

Shaft seal

Additional
information

TP Series 100

TP Series 200

<+90C

BQQE

AUUE

BQQE

TP Series 300

TP Series 400
PN 10

TP Series 400
PN 25

BAQE

DBUE

Water

>+90C

BUBE

BUBE

BAQE1)
BBQE3)

Boiler feed water

<+120C

BUBE

BUBE

BAQE

BAQE

DBUE

District heating water

<+120C

BUBE

BUBE

BAQE

BAQE

DBUE

<+90C

BQQE

AUUE

BQQE

>+90C

BUBE

BUBE

BAQE

BAQE

DBUE

<+90C

BQQE

AUUE

BQQE

>+90C

BUBE

BUBE

BAQE

BAQE

DBUE

Groundwater

Condensate
Softened water

Brackish water

pH>6.5, +40C,
1000 ppm Cl-

BUBE
BQQE

BUBE
AUUE

BQQE

BQQE

DBUE

Ethylene glycol

B, D, H

+50C, 50%

BQQE
GQQE

AUUE
RUUE

BAQE2)
BQQE
GQQE

GQQE

DQQE3)

Glycerine (glycerol)

B, D, H

+50C, 50%

BQQE
GQQE

AUUE
RUUE

BQQE
GQQE

GQQE

DQQE3)

Potassium acetate

B, D, C, H

+50C, 50%

BQQE
GQQE

AUUE
RUUE

BQQE
GQQE

GQQE

DQQE3)

Potassium formate

B, D, C, H

+50C, 50%

BQQE
GQQE

AUUE
RUUE

BQQE
GQQE

GQQE

DQQE3)

BQQE
GQQE

AUUE
RUUE

BAQE2)
BQQE
GQQE

GQQE

DQQE3)

BQQE
GQQE

AUUE
RUUE

BQQE
GQQE

GQQE

DQQE3)

BUBE
BQQE

BUBE
AUUE

BAQE
BQQE

BAQE

DBUE

Coolants

Propylene glycol
Brine-sodium chloride

B, D, H
B, D, C, H

+5C, 30%

Synthetic oils
Silicone oil

B, E

(To be continued)

20

Pumped liquids

Pumped liquids

Notes

Additional
information

TP, TPD, TPE, TPED

Shaft seal
TP Series 100

TP Series 200

TP Series 300

TP Series 400
PN 10

TP Series 400
PN 25

BUBV3)
BQQV 3)

BUBV 3)
AUUV3)

BAQV3)
BQQV3)

BAQV3)

DBUV3)

BUBV3)
BQQV 3)

BUBV 3)
AUUV3)

BAQV3)
BQQV3)

BAQV3)

DBUV3)

Vegetable oils
Corn oil

B, F, E

Olive oil

B, F, E

Peanut oil

B, F, E

BUBV3)
BQQV 3)

BUBV 3)
AUUV3)

BAQV3)
BQQV3)

BAQV3)

DBUV3)

D, B, F, E

BUBV3)
BQQV 3)

BUBV 3)
AUUV3)

BAQV3)
BQQV3)

BAQV3)

DBUV3)

B, F, E

BUBV3)
3)

BUBV 3)
3)

BAQV3)
3)

BAQV3)

DBUV3)

Rape seed oil


Soya bean oil

<+80C

BQQV

AUUV

BQQV

Cleaning agents
Soap (salts of fatty acids)

A, E, (F)

<+80C

BQQE (BQQV)3)

AUUE (AUUV)3)

BQQE (BQQV)3)

GQQE

DQQE3)

Alkaline degreasing agent

A, E, (F)

<+80C

BQQE (BQQV)3)

AUUE (AUUV)3)

BQQE (BQQV)3)

GQQE

DQQE3)

<+40C, <2%

BUBE
BQQE

BUBE
AUUE

BQQE

BQQV 3)

DQQE3)

Oxidants
Hydrogen peroxide
Salts
Ammonium bicarbonate
Calcium acetate
Potassium bicarbonate

<+20C, <15%

BQQE

AUUE

BQQE

GQQE

DQQE3)

A, B

<+20C, <30%

BQQE

AUUE

BQQE

GQQE

DQQE3)

<+20C, <20%

BQQE

AUUE

BQQE

GQQE

DQQE3)

Potassium carbonate

<+20C, <20%

BQQE

AUUE

BQQE

GQQE

DQQE3)

Potassium permanganate

<+20C, <10%

BQQE

AUUE

BQQE

GQQE

DQQE3)

Potassium sulfate

<+20C, <20%

BQQE

AUUE

BQQE

GQQE

DQQE3)

Sodium acetate

<+20C, <100%

BQQE

AUUE

BQQE

GQQE

DQQE3)

Sodium bicarbonate

<+20C, <2%

BQQE

AUUE

BQQE

GQQE

DQQE3)

Sodium carbonate

<+20C, <20%

BQQE

AUUE

BQQE

GQQE

DQQE3)

Sodium nitrate

<+20C, <40%

BQQE

AUUE

BQQE

GQQE

DQQE3)

Sodium nitrite

<+20C, <40%

BQQE

AUUE

BQQE

GQQE

DQQE3)

Sodium phosphate (di)

<+100C, <30%

BQQE

AUUE

BQQE

GQQE

DQQE3)

Sodium phosphate (tri)

<+90C, <20%

BQQE

AUUE

BQQE

GQQE

DQQE3)

Sodium sulfate

<+20C, <20%

BQQE

AUUE

BQQE

GQQE

DQQE3)

Sodium sulfite

<+20C, <1%

BQQE

AUUE

BQQE

GQQE

DQQE3)

<+100C, <30%

BQQE

AUUE

BQQE

GQQE

DQQE3)

Calcium hydroxide

<+100C, <10%

BQQE

AUUE

BQQE

GQQE

DQQE3)

Potassium hydroxide

<+20C, <20%

BQQE

AUUE

BQQE

GQQE

DQQE3)

Sodium hydroxide

<+40C, <20%

BQQE

AUUE

BQQE

GQQE

DQQE3)

Alkalis
Ammonium hydroxide

(1
(2
(3

BAQE must not be used for potable water. For potable water we recommend you to fit the pump with a BBQE shaft seal.
BAQE can be used in air-condition applications at temperatures above 0C.
The shaft seal is not standard, but available on request.

21

TP Series 100 and 200 pumps

TP, TPD, TPE, TPED


Series 100 and 200

Pumps with bronze pump housing (version B) are suitable for circulation of domestic hot water.

Materials

GR8262 - GR8261

TP, TPE Series 100

TP Series 100 and TP Series 200

Technical data

TM03 1210 1405

Fig. 2

5
4
3
2
1

Flow rate:
up to 90 m3/h
Head:
up to 27 m
Liquid temperature (TP Series 100): 25 to +110 C
Liquid temperature (TP Series 200): 25 to +140 C
Max. operating pressure:
up to 16 bar

Fig. 3 Sectional drawing of TP Series 100 (with union


connection)

Material specification Series 100

Construction
Grundfos TP Series 100 and Series 200 pumps are single-stage, close-coupled pumps with in-line suction and
discharge ports of identical diameter.
The pumps are equipped with a fan-cooled asynchronous motor. Motor and pump shafts are connected via
a rigid two-part coupling.

Pos. Component

Material

EN/DIN

Cast iron EN-GJL-200,


bronze CuSn10

EN-JL 1030
2.1093
1.4301

Pump housing

Impeller

Stainless steel

Shaft

Stainless steel

1.4057

Coupling

Cast iron EN-GJL-400

0.7040

Pump head

Cast iron EN-GJL-250,


bronze

0.6025
2.1093

Secondary seals

EPDM

TP Series 100 pumps with union connection are available as single-head (TP, TPE) pumps.

Rotating seal
face

Tungsten carbide
silicon carbide

TP Series 200 pumps are available as single-head (TP,


TPE) and twin-head (TPD, TPED) models.

Stationary seat

Carbon (synthetic resinimpregnated)


silicon carbide

TP Series 200 pumps have flange connection and are


equipped with either PN 6/10 combination flanges or
PN 10 flanges.

TP, TPE Series 200

The pumps are equipped with an unbalanced mechanical shaft seal.

The twin-head pumps are designed with two parallel


power heads. A non-return flap valve in the common
discharge port is opened by the flow of the pumped
liquid and prevents backflow of liquid into the idle pump
head.
As radial and axial forces are absorbed by the fixed
bearing in the motor drive-end, the pump requires no
bearing.
2- and 4-pole TP, TPD, TPE, TPED Series 100 and 200
pumps as from 1.1 kW are equipped with high-efficiency motors
.

22

4
3

2
1

TM03 1211 1405

The pumps are of the top-pull-out design, i.e. the power


head (motor, pump head and impeller) can be removed
for maintenance or service while the pump housing
remains in the pipework.

Fig. 4 Sectional drawing of a single-phase TPE Series


200 (flanged model)

TP Series 100 and 200 pumps

Connections

Material specification Series 200


Pos. Component

Material

EN/DIN

Pump housing

Cast iron EN-GJL-250,


bronze CuSn10

EN-JL 1040
2.1093

Impeller

Stainless steel

1.4301

Shaft

Stainless steel

1.4305

Coupling

Cast iron EN-GJL-400

0.7040

Pump head

Cast iron EN-GJL-250,


bronze

0.6025
2.1093

Secondary seals

EPDM

Rotating seal
face

Tungsten carbide

Stationary seat

Carbon (synthetic resinimpregnated)


tungsten carbide

TP, TPD, TPE, TPED


Series 100 and 200

Mechanical shaft seal


Three types of unbalanced mechanical shaft seal are
available as standard:

TP Series 100 pumps with union connection have suction and discharge union threads to ISO 228-1.
TP Series 200 pumps up to DN 65 are equipped with
combination flanges PN 6/PN 10. DN 80 or DN 100
pumps have either PN 6 or PN 10 flanges. All flanges
can be connected to flanges in accordance with EN
1092-2 and ISO 7005-2.

Control
Electronically controlled TPE, TPED pumps are suitable for demand-dependent performance control. The
standard models TP Series 100 and TP, TPD Series
200 can also be used for demand-dependent performance control if they are connected to a Grundfos Delta
Control system.

BUBE
The BUBE shaft seal is a Grundfos rubber bellows
seal with tungsten carbide/carbon seal faces and
secondary seals of EPDM.

Product features and benefits

RUUE/GQQE
The RUUE shaft seal is a Grundfos O-ring seal with
reduced tungsten carbide/tungsten carbide seal
faces and secondary seals of EPDM.
The GQQE shaft seal is a Grundfos rubber bellows
seal with reduced seal faces and silicon carbide/silicon carbide seal faces and secondary seals of
EPDM.

Optimised hydraulics for high efficiency


- reduced power consumption.
High-efficiency motors
- 2-pole and 4-pole TP pumps from 1.1 kW and
upwards have EFF 1 motors fitted as standard.
EFF 1 motors offer reduced current consumption.
TPE, TPED - pumps with built-in frequency
converter
- 2-pole and 4-pole TP pumps from 0.37 and
upwards are available as TPE pumps with built-in
frequency converter. For further information, see
page 10.
Top-pull-out design
- easy dismantling in case of service.
In-line design
- contrary to end-suction pumps, in-line pumps
allow a straight pipework and thus often reduced
installation costs.
Pump housing and pump head are electrocoated
- high corrosion resistance.

AUUE/BQQE
The AUUE shaft seal is a Grundfos O-ring seal with
fixed seal driver, tungsten carbide/tungsten carbide
seal faces and secondary seals of EPDM.
The BQQE shaft seal is a Grundfos rubber bellows
seal with silicon carbide/silicon carbide seal faces
and secondary seals of EPDM.
Information on a selection of common pumped liquids
with recommended shaft seals is shown on page 20.
Shaft seal specification
TP, TPE Series version KU according to EN
100
12756
Unbalanced shaft seal TP, TPD, TPE,
TPED Series
200

version NU according to EN
12756

Shaft diameter

12 and 16 mm

Rubber bellows

EPDM
Tungsten carbide/carbon

Seal faces

Tungsten carbide/
tungsten carbide
Silicon carbide/
silicon carbide

Special shaft seals are available for partly conditioned


water or other liquids containing abrasive or crystallising particles. See page 20.

TP Series 100 and Series 200 pumps have the


following features and benefits:

Electrocoating includes:
1.
2.
3.
4.

Alkaline cleaning
Pre-treatment with zinc phosphate coating
Cathodic electrocoating (epoxy)
Curing of paint film at 200-250C.

For low-temperature applications at a high


humidity, Grundfos offers TP pumps with extra
surface treatment to avoid corrosion. These
pumps are available on request.
Stainless steel impeller and neck ring
- wear-free operation with high efficiency.

23

TP Series 300 pumps

TP, TPD, TPE, TPED


Series 300

Materials

Fig. 5

Fig. 6

TM03 1212 1405

GR8259

4
3
2
1

Sectional drawing of TP Series 300

TP Series 300

Material specification

Technical data
Flow rate:
Head:
Liquid temperature:
Max. operating pressure:

Pos. Component

up to 380 m 3/h
up to 93 m
25 to +140 C
16 bar

Construction
Grundfos TP, TPD Series 300 pumps are single-stage,
close-coupled pumps with in-line suction and discharge
ports of identical diameter.
The pumps are equipped with a fan-cooled asynchronous motor. Motor and pump shafts are connected via
a rigid sleeve coupling.
TP Series 300 pumps are available as single-head (TP,
TPE) and twin-head (TPD, TPED) models.
TP Series 300 pumps have flange connection and are
equipped with PN 16 flanges.
The pumps are equipped with an unbalanced mechanical shaft seal.
The pumps are of the top-pull-out design, i.e. the power
head (motor, pump head/motor stool and impeller) can
be removed for maintenance or service while the pump
housing remains in the pipework.
The twin-head pumps are designed with two parallel
power heads. A non-return flap valve in the common
discharge port is opened by the flow of the pumped liquid and prevents backflow of liquid into the idle pump
head.
As radial and axial forces are absorbed by the fixed
bearing in the motor drive-end, the pump requires no
bearing.

24

Material

EN/DIN

Pump housing

Cast iron EN-GJL-250

EN-JL 1040

Impeller

Cast iron EN-GJL-200,


bronze CuSn5Zn5Pb

EN-JL 1030
2.1096.01

Shaft/sleeve
coupling

Steel/stainless steel

Motor stool/
pump head

Cast iron EN-GJL-250

Secondary seals

EPDM

Rotating seal
face

Metal-impregnated carbon,
silicon carbide

Stationary seat

Silicon carbide

EN-JL 1040

Mechanical shaft seal


Three types of unbalanced mechanical shaft seal are
available as standard:
BAQE
The BAQE shaft seal is a Grundfos rubber bellows
seal with carbon/silicon carbide seal faces and secondary seals of EPDM.
GQQE
The GQQE shaft seal is a Grundfos rubber bellows
seal with reduced silicon carbide/silicon carbide
seal faces and secondary seals of EPDM.
BQQE
The BQQE shaft seal is a Grundfos rubber bellows
seal with silicon carbide/silicon carbide seal faces
and secondary seals of EPDM.
Information on a selection of common pumped liquids
with recommended shaft seals is shown on page 20.
Shaft seal specification
Unbalanced shaft seal

version NU according to EN
12756

Shaft diameter

28 and 38 mm

2- and 4-pole TP, TPD, TPE, TPED Series 300 pumps


as from 1.1 kW are equipped with high-efficiency
motors
.

Rubber bellows

TP Series 300 pumps with bronze impeller are suitable


for pumping brine.

Special shaft seals are available for partly conditioned


water or other liquids containing abrasive or crystallising particles. See page 20.

Seal faces

EPDM
Carbon/silicon carbide
Silicon carbide/silicon carbide

TP Series 300 pumps

TP, TPD, TPE, TPED


Series 300

Connections
TP Series 300 pumps are equipped with PN 16 flanges.
All dimensions are according to ISO 7005-2 or EN
1092-2.

Control
Electronically controlled TPE, TPED pumps are suitable for demand-dependent performance control. The
standard models TP, TPD Series 300 can also be used
for demand-dependent performance control if they are
connected to Grundfos Delta Control system.
Noise and detrimental voltage peaks can be prevented
by fitting an LC filter between the speed controller and
the motor.

Product features and benefits


TP Series 300 pumps have the following features and
benefits:
Optimised hydraulics for high efficiency
- reduced power consumption.
High-efficiency motors
- 2-pole and 4-pole TP pumps from 1.1 kW and
upwards have EFF 1 motors fitted as standard.
EFF 1 motors offer reduced current consumption.
TPE, TPED - pumps with built-in frequency
converter
- 2-pole and 4-pole TP pumps from 0.37 and
upwards are available as TPE pumps with built-in
frequency converter. For further information, see
page 10.
Top-pull-out design
- easy dismantling in case of service.
In-line design
- contrary to end-suction pumps, in-line pumps
allow a straight pipework and thus often reduced
installation costs.
Pump housing and pump head/motor stool are
electrocoated
- high corrosion resistance.
Electrocoating includes:
1.
2.
3.
4.

Alkaline cleaning
Pre-treatment with zinc phosphate coating
Cathodic electrocoating (epoxy)
Curing of paint film at 200-250C.

For low-temperature applications at a high


humidity, Grundfos offers TP pumps with extra
surface treatment to avoid corrosion. These
pumps are available on request.

25

TP Series 400 pumps

TP
Series 400

Materials
5

TM02 8492 0204

GR7539

Fig. 8 Sectional drawing of TP Series 400

Fig. 7

Material specification

TP Series 400

TP Series 400, PN 10

Technical data
Flow rate:
Head:

PN
PN
PN
PN

10
25
10
25

Pos. Component

version:
version:
version:
version:

30 to 1000 m 3/h
30 to 4500 m3/h
up to 80 m
up to 170 m

Liquid
temperature:

EN/DIN
EN-JL1040

Ductile cast iron EN-GJS-400

EN-JL1030

Impeller

Pump shaft

Stainless steel

1.4436

Coupling

Cast iron EN-GJL-250

EN-JL1040

Motor stool

Cast iron EN-GJL-250

EN-JL1040

Secondary seals

EPDM rubber

Rotating seal face

Carbon, metal-impregnated or
Silicon carbide

Stationary seat

Silicon carbide

Bronze

TP Series 400, PN 25
10 bar version:
25 bar version:
25 bar version (DN 400):

10 bar
25 bar
25 bar

Pos. Component
1
2

Construction
Grundfos TP Series 400 pumps are single-stage, closecoupled pumps with in-line suction and discharge ports.
The pumps are equipped with a fan-cooled asynchronous motor. Motor and pump shafts are connected via
a rigid flange coupling.
TP Series 400 pumps are available as single-head (TP)
models.
All TP Series 400 pumps have flange connection PN 10
or PN 25. The largest pumps have DN 400, PN 40
discharge flanges and a maximum operating pressure
of 25 bar.
The pumps are equipped with an unbalanced mechanical shaft seal.
The pumps are of the top-pull-out design, i.e. the power
head (motor, motor stool and impeller) can be removed
for maintenance or service while the pump housing
remains in the pipework.
As radial and axial forces are absorbed by the fixed
bearing in the motor drive-end, the pump requires no
bearing.
2- and 4-pole TP, TPE Series 400 pumps as from
5.5 kW are equipped with high-efficiency motors

26

Material
Cast iron EN-GJL-250

PN 10 version:
25 to +120C
PN 25 version:
0 to +150C
From +120 to +150C, max. 23 bar
Max. operating
pressure:

Pump housing

Material

EN/DIN

Pump housing

Ductile cast iron


EN-GJS-400-18 (A-LT)

EN-JS1020

Impeller

Ductile cast iron EN-GJS-400

EN-JS1030

Bronze

Pump shaft

Stainless steel

1.4436

Coupling

Cast iron EN-GJL-250

EN-JL1040

Motor stool

Cast iron EN-GJL-250

EN-JL1040

Secondary seals

EPDM rubber

Rotating seal face

Carbon, synthetic
resin-impregated

Stationary seat

Tungsten carbide

TP Series 400 pumps

TP
Series 400

Mechanical shaft seal

Product features and benefits

For 10 bar versions, the following three types of unbalanced mechanical shaft seal are available as standard:

TP Series 400 pumps have the following features and


benefits:

BAQE
The BAQE shaft seal is a Grundfos rubber bellows
seal with carbon/silicon carbide seal faces and secondary seals of EPDM.

Optimised hydraulics for high efficiency


- reduced power consumption.
High-efficiency motors
- 2-pole and 4-pole pumps as from 5.5 kW to 90 kW
have EFF 1 motors fitted as standard.
EFF 1 motors offer reduced current consumption.
Top-pull-out design
- easy dismantling in case of service.
In-line design
- contrary to end-suction pumps, in-line pumps
allow a straight pipework and thus often reduced
installation costs.
Cast iron impeller and bronze neck rings
- easy to replace during service.
Motor-pump shaft with flange coupling
- stable and quiet operation
- easy dismantling in case of service.
Supported flange connection
- pump housing flanges have integrated feet in
order to stabilise the pump.
Different suction and discharge ports
- the suction port is one dimension larger than the
discharge port in order to obtain a low inlet
velocity. This reduces risk of cavitation and noise.
Surface treatment
TP Series 400 pumps are given the following
surface treatment:

GQQE
The GQQE shaft seal is a Grundfos rubber bellows
seal with reduced silicon carbide/silicon carbide
seal faces and secondary seals of EPDM.
BQQE
The BQQE shaft seal is a Grundfos rubber bellows
seal with silicon carbide/silicon carbide seal faces
and secondary seals of EPDM.
For 25 bar versions, the following mechanical shaft seal
is available as standard:
DBUE
The DBUE shaft seal is a Grundfos balanced O-ring
seal with carbon/tungsten carbide seal faces and
secondary seals of EPDM.
Information on a selection of common pumped liquids
with recommended shaft seals is shown on page 20.
Special shaft seals are available for partly conditioned
water or other liquids containing abrasive or crystallising particles. See page 20.

Connections
TP Series 400 pumps are the only TP pumps with
suction and discharge ports of different diameters. The
suction port is one dimension larger than the discharge
port in order to obtain a low inlet velocity. This reduces
risk of cavitation and noise.
From DN 100 to DN 300 TP Series 400 pumps have
flanges according to ISO 7005-2 or EN 1092-2.

Pump type

Electrocoating

Spray painting

TP Series 400
(from DN 100 to DN 300)
TP Series 400 (DN 400)

2x

Electrocoating includes:
1. Alkaline cleaning
2. Pre-treatment with zinc phosphate coating
3. Cathodic electrocoating (epoxy)
4. Curing of paint film at 200-250C.
For low-temperature applications at a high
humidity, Grundfos offers TP pumps with extra
surface treatment to avoid corrosion. These
pumps are available on request.

27

TPE Series 2000 pumps

TP, TPD, TPE, TPED


Series 2000

Applications
TPE Series 2000 pumps have integrated speed control
for automatic adaptation of performance to current
conditions.

TM03 0348 4904

This ensures that the energy consumption is kept at a


minimum.

Fig. 9

TPE Series 2000 pumps can operate in any duty point


within the range between 25% and 100% speed.
H
[m]

TPE and TPED Series 2000

100%

Flow rate:
Head:
Liquid temperature:
Max. operating pressure:

up to 220 m 3/h
up to 39 m
25 to +140C
16 bar

Motor sizes (single-phase): 0.37 to 1.1 kW


Motor sizes (three-phase): 0.75 to 22 kW

25%

0
0

Construction

Q [m/h]

TPE, TPED Series 2000 pumps are based on TP, TPD


pumps.

In the QH-chart the 100%-curve corresponds to the


curve for a pump fitted with a standard fixed-speed
motor.

The main differences between the TP and the TPE


Series 2000 pump range are the motor and the factoryfitted integrated differential pressure sensor.

Depending on the nature of the application, TPE Series


2000 pumps offer energy-savings, increased comfort or
improved processing.

The motor of TPE Series 2000 pumps has built-in


frequency converter designed to continuously regulate
the pressure to the flow.

TPE Series 2000 pumps are suitable for applications


where you want to control the pressure.

The TPE Series 2000 range is recognized as a pre-set


solution for quick and safe installation.

TPE Series 2000 pumps are factory-set to proportional


pressure. We recommend proportional pressure control
in systems with relatively large pressure losses as it is
the most economical control mode.

A second sensor can be retrofitted in order to obtain


security of back-up.
For further information on construction and materials of
TPE Serie 2000 pumps, see page 22 to 25.

Proportional pressure

TPE Series 2000 pumps set to proportional pressure


control continuously adjust the pump head to the
system water requirement. The setpoint is factory-set to
be half of the max. pump head.
The pumps can be retro-fitted with sensor types
meeting the requirements mentioned in the data
booklet titled Grundfos E-pumps.

28

TM01 4916 1099

Technical data

TPE Series 2000 pumps

The charts below show possible control modes of TPE


Series 2000 pumps in different applications.
Control mode

Application

Proportional pressure
Systems with two-way valves
- the head against closed valve is half the
setpoint.

Constant pressure
Systems with two-way valves.

TP, TPD, TPE, TPED


Series 2000

Operating modes of twin-head


pumps
The following operating modes are available for twinhead pumps:
Alternating operation. The two pumps run alternately
for 24 operating hours. In case of fault in the operating
pump, the other pump will start up.
Standby operation. One pump is in constant operation. Every 24 operating hours the standby pump will
start up and run for a short period to prevent it from
seizing up. In case of fault in the operating pump, the
standby pump will start up.
The operating mode is selected by means of a selector
switch in each terminal box.
In case of fault in the sensor the operating pump will
switch to maximum operation.

Constant curve
Single-pipe heating system.
Systems with three-way valves.

Control options

Heating and cooling surfaces.


Chiller pumps

Communication with TPE, TPED Series 2000 pumps is


possible via
a central building management system
remote control (Grundfos R100) or
a control panel.
The purpose of controlling TPE, TPED Series 2000
pumps is to monitor and control the pressure, temperature, flow and liquid level of the system.
For further information on control options of TPE
pumps, see page 32.

29

TPE Series 1000 pumps

TP, TPD, TPE, TPED


Series 1000

Applications
TPE Series 1000 pumps have integrated speed control
for automatic adaptation of performance to current
conditions.

TM03 0347 4904

This ensures that the energy consumption is kept at a


minimum.
TPE Series 1000 pumps can operate in any duty point
within the range between 25% and 100% speed.
H
[m]
100%

Fig. 10 TPE and TPED Series 1000

Flow rate:
Head:
Liquid temperature:
Max. operating pressure:

up to 380m3/h
up to 90 m
25 to +140C
16 bar

Motor sizes (single-phase): 0.37 to 1.1 kW


Motor sizes (three-phase): 0.75 to 22 kW

Construction
TPE, TPED Series 1000 pumps are based on TP, TPD
pumps.
The main difference between the TP and the TPE
Series 1000 pump range is the motor.
The motor of TPE Series 1000 pumps has built-in
frequency converter designed to continuously regulate
the pressure to the flow.
TPE Series 1000 pumps are suitable for applications
where you want to retrofit a sensor in order to control
e.g. the pressure, temperature, flow etc. at some arbitrary point in the system.
For further information on construction and materials of
TPE Series 1000 pumps, see page 22 to 25.

30

25%

0
0

Q [m/h]

TM01 4916 1099

Technical data

In the QH-chart the 100%-curve corresponds to the


curve for a pump fitted with a standard fixed speed
motor.
Depending on the nature of the application, TPE Series
1000 pumps offer energy-savings, increased comfort or
improved processing.
The pumps can be fitted with sensor types meeting the
requirements mentioned in the data booklet titled
Grundfos E-pumps.

TPE Series 1000 pumps

The charts below show possible control modes of TPE


Series 1000 pumps in different applications.
Control mode

Application

Constant curve
Single-pipe heating systems.
Systems with three-way valves.
Heating and cooling surfaces.
Chiller pumps.

Constant differential pressure


Systems with two-way valves.
(Sensor is needed)

TP, TPD, TPE, TPED


Series 1000

Operating modes of twin-head


pumps
The following operating modes are available for twinhead pumps:
Alternating operation. The two pumps run alternately
for 24 operating hours. In case of fault in the operating
pump, the other pump will start up.
Standby operation. One pump is in constant operation. Every 24 operating hours the standby pump will
start up and run for a short period to prevent it from
seizing up. In case of fault in the operating pump, the
standby pump will start up.
The operating mode is selected by means of a selector
switch in each terminal box.

Temperature control
Single-pipe heating systems.
Systems with three-way valves.
Cooling towers.
Chiller pumps.
Domestic hot water recirculation systems.
(Sensor is needed)

In case of fault in the sensor the operating pump will


switch to maximum operation.

Control options
Communication with TPE, TPED Series 1000 pumps is
possible via
a central building management system

Constant flow
Heating and cooling surfaces.
Cooling towers.
Flow filters.
(Sensor is needed)

Proportional differential pressure (measured)


System with two-way valves.
(Differential pressure sensor is located in the
system)

remote control (Grundfos R100) or


a control panel.
The purpose of controlling a TPE, TPED Series 1000
pumps is to monitor and control the pressure, temperature, flow and liquid level of the system.
For further information on control options of TPE
pumps, see page 32.

31

Communication

TPE, TPED

Communication with TPE, TPED


pumps

Remote control
The R100 remote control produced by Grundfos is
available as an accessory.

Communication with TPE, TPED pumps is possible via


a central building management system, remote control
(Grundfos R100) or a control panel.

The operator can communicate with the TPE, TEPD


pump by pointing the IR-signal transmitter at the control
panel of the terminal box.

Central building management system

TM03 0141 4104

The operator can communicate with a TPE, TPED


pump even though he is not present near the pump.
Communication can take place via a central building
management system allowing the operator to monitor
and change control modes and setpoint settings.

Fig. 12 R100 remote control

The operator can monitor and change control modes


and settings of the TPE, TPED pump via the R100
display.
LON-bus connection

Control panel

GENIbus connection

TPE pump

Fig. 11 Structure of a central building management


system

32

TM02 6592 1103

G10-LON
Interface

TM00 7600 0404

The operator can change the setpoint settings manually


on the control panel of the TPE, TPED pump terminal
box.

Fig. 13 Control panel on a TPE pump

Speed regulation of TPE pumps

TPE, TPED

Affinity equations
Normally, TPE, TPED pumps are used in applications
characterised by a variable flow. Consequently, it is not
possible to select a pump that is constantly operating at
its optimum efficiency.

Q
n
n
n
------- = ------Q
n
x
x

Hn

In order to achieve optimum operating economy, the


pump should be selected on the basis of the following
criteria:

Hx

H
n n 2
n
------- = -------
H
n x
x

nn
nx

The max. duty point required should be as close as


possible to the QH curve of the pump.
The flow rate at the duty point required should be
close to the optimum efficiency (eta) for most operating hours.

Eta

Qx

Qn
n
------- 1

Between the min. and max. performance curve TPE,


TPED pumps have an infinite number of performance
curves each representing a specific speed. Therefore,
it may not be possible to select a duty point close to the
max. curve.

nx

H
[m]

nn

Q
Max. curve

Qn
nn

Pn

P
n n 3
n
------ = -------
Px
n x

nx

Px

Q [m/h]

TM01 4916 4803

Min. curve

Fig. 14 Min. and max. performance curves

In situations where it is not possible to select a duty


point close to the max. curve, use the affinity equations
below. The head (H), the flow (Q) and the input power
(P) are the appropriate variables you need to be able to
calculate the motor speed (n).
Note:
The approximated formulas apply on condition that the system
characteristic remains unchanged for nn and nx and that it is
based on the formula H = k x Q2 , where k is a constant.
The power equation implies that the pump efficiency is
unchanged at the two speeds. In practice this is not quite
correct.
Finally, it is worth noting that the efficiencies of the frequency
converter and the motor must be taken into account if a
precise calculation of the power saving resulting from a reduction of the pump speed is wanted.

TM00 8720 3496

Qx

Fig. 15 Affinity equations

Legend
Hn
Hx
Qn
Qx
nn
nx
n
x

Rated head in metres


Current head in metres
Rated flow in m3/h
Current flow in m3/h
Rated motor speed in min-1
Current motor speed in min-1
Rated efficiency in %
Current efficiency in %

WinCAPS and WebCAPS


WinCAPS and WebCAPS are both selection programs
offered by Grundfos.
The two programs make it possible to calculate a TPE
pumps specific duty point and energy consumption.
When you enter the dimensions of the pump, WinCAPS
and WebCAPS can calculate the exact duty point and
energy comsumption. For further information, see
page 161.

33

Motors for TP pumps

Motors

High-efficiency motors

Motors fitted on TP pumps are totally enclosed, fancooled standard motors with main dimensions to IEC
and DIN standards. Electrical tolerances to IEC 34.

Mounting designation
Pump type

Mounting designation - IEC 34-7

TP Series 100
TP Series 200

IM 3601 (IM B 14) /IM 3611 (IM V 18)

TP Series 300

IM 3001 (IM B 5) /IM 3011 (IM V 1)

TP Series 400

IM 3601 (IM B 14) /IM 3611 (IM V 18


IM 3001 (IM B 5) /IM 3011 (IM V 1)

Relative humidity:
Enclosure class:
Insulation class:
Ambient temperature:

Max. 95%
IP 55
F, to IEC 85
Max. +60C (EFF 1 motors)
Max. +40C (other motor sizes).

If the pump is installed in humid locations, open the


lowest drain hole in the motor. This will reduce the
motor enclosure class to IP 44.

Motor range
kW

Standard motors

Electronically speed-controlled
motors
2-pole
4-pole

2-pole 4-pole 6-pole


0.12
MMG
0.18 MMG
0.25
0.37
MG
MG
0.55
0.75
1.1
1.5
MGE
2.2
MG
3.0
MG
MMG
4.0
5.5
7.5
11.0
15.0
MMGE
18.5
22.0
MMG
30.0
MMG
37.0
45.0
55.0
75.0
90.0
110.0
132.0
160.0 MMG
200.0
250.0
MMG
315.0
355.0
400.0
500.0
560.0
630.0
MG and MGE are Grundfos motor brands.
MMG and MMGE are sourced motor brands.
The grey-shaded areas indicate non-available motors.

34

TP, TPD, TPE, TPED

TP, TPD pumps with 2- and 4-pole three-phase motors


from 1.1 to 90 kW are equipped with EFF 1 motors.
TPE, TPED pumps with three-phase motors, 2-pole
from 1.1 to 7.5 kW and 4-pole from 1.1 to 4.0 kW, are
equipped with motors equivalent to EFF 1.
EFF 1 is the highest efficiency class defined by
CEMEP.

Motor protection
Single-phase motors have integrated, interconnected
thermal switches.
Three-phase motors must be connected to a motor
starter.
All three-phase standard motors can be connected to
an external frequency converter.
If you connect a frequency converter the motor insulation system will often be overloaded, and the motor will
be more noisy than in normal operation. In addition,
large motors will be exposed to bearing currents
caused by the frequency converter.
If you operate the motor via a frequency converter,
considered the following:
In 2-, 4- and 6-pole motors of 75 kW (frame size
250) and upwards, isolate one of the motor bearings
electrically to prevent damaging currents from passing through the motor bearings.

MGE

MMGE

If you have noise-sensitive applications, you can reduce the motor noise by fitting a dU/dt filter between
the motor and the frequency converter.
In particularly noise-sensitive applications, we recommend you to fit a sinusoidal filter.
The length of the cable between motor and frequency converter affects the motor load. Therefore,
check that the cable length meets the specifications
laid down by the frequency converter supplier.
For supply voltages between 500 and 690 V, fit
either a dU/dt filter to reduce voltage peaks or use a
motor with reinforced insulation.
For supply voltages of 690 V, use a motor with reinforced insulation and fit a dU/dt filter.

Motors for TP pumps

TP, TPD, TPE, TPED

Electrical data, standard motors


Electrical data, 2-pole

1x220-230/240 V

Electrical data, 4-pole

1x220-230/ 240 V

0.12

1.05

65

2800-2840

IStart
----------------I 1/1
3.2-3.6

0.12

0.99

0.99

53.1

1434

0.25

2.05/2

0.99

58

2800

0.18

1.62

0.97

54

1350-1370

0.37

2.95/2.7

0.99

60

2770

2.8

0.25

2.14

0.97

57

1350-1370

2.2

0.55

4/3.65

0.99

66

2750

2.8

0.37

2.85

0.97

62

1350-1370

2.4

0.75

5.1/4.75

0.99

69

2780

0.55

0.97

66

1350-1370

2.6

1.1

7.4/6.7

0.98-0.99

2770

3.9/3.9

0.75

5.45

0.96

71

1390-1410

3.2

1.5

9.9/8.9

0.98-0.99

72-74

2750-2740

3.9/3.9

1.1

0.96

75

1420-1430

3.9

Motor
[kW]

I1/1 [A]

Cos 1/1

[%]

n [min-1]

Electrical data, 2-pole


Motor
[kW]

I1/1 [A]

0.12
0.18

3x220-240/380-415 V

Motor
[kW]

I1/1 [A]

Cos 1/1

[%]

Electrical data, 4-pole

n [min-1]

IStart
----------------I 1/1
2.58

3 x 220-240/380-415 V

Motor
[kW]

2800 -2850

IStart
----------------I 1/1
4.2-4.6

0.12

0.78/0.45

0.67

54

1380

2800-2850

4.5

0.25

1.48/0.85

0.75-0.65

69

1400-1420

4-4.4

73

2800 -2850

4-4.4

0.37

1.9/1.1

0.77-0.67

71

1400-1420

4-4.4

77.577.5

2850-2880

0.55

2.6/1.5

0.79-0.7

77

1390-1410

4.3-4.7

0.75

3.3/1.9

0.79-0.7

78

1390-1410

4.3-4.7

Cos 1/1

[%]

n [min-1]

0.59/0.34

0.8-0.72

71

0.9/0.52

0.79-0.71

67

0.25

1.18/0.68

0.81-0.72

0.37

1.74/1

0.8-0.7

I1/1 [A]

Cos 1/1

[%]

n [min-1]

IStart
----------------I 1/1
3.2

0.55

2.5/1.44

0.8-0.7

79-79

2830-2850

1.1

4.3/2.5

0.76

83.8

1430

6.1

0.75

3.3/1.9

0.81-0.71

80-80

2840-2870

1.5

5.9/3.4

0.76

85

1430

6.4

1.1

4.10/2.35

0.87-0.82

84

2890-2910

7.4-8

2.2

9/5.2

0.71

86.4

1450

1.5

5.45/3.15

0.87-0.82

85.5

2890-2910

8.5-9.3

3.0

11.8/6.75

0.81-0.73

87.5

1450-1460

6.7-7.3

2.2

7.70/4.45

0.89-0.87

87.5

2890-2910

8.5-9.5

4.0

14.7/8.5

0.77

88.3

1450

6.1

3.0

10.4/5.95

0.88-0.85

88-88

2910-2930

5.5

19.5/11.3

0.84

89.2

1450

7.4

4.0

13.8/8

0.88-0.84

89

2910-2930

11.2-12.3

7.5

26/15

0.84

90.1

1450

7.4

5.5

19.4/11.2

0.88-0.84

90

2910-2930

10.7-11.7

11.0

39/22.5

0.82

91

1460

6.9

7.5

26.5/15.2

0.87-0.8

89.5

2900-2920

10-11.1

15.0

51/29.5

0.84

91.8

1460

7.4

11.0

36.5/21

0.86

90.7

2930

7.3

18.5

62/36

0.84

92.2

1460

7.5

15.0

48.5/28

0.86

91.6

2930

7.6

22.0

74/42.5

0.85

92.6

1465

7.8

18.5

60/34.5

0.86

92

2930

7.9

30.0

101/58.5

0.84

93.2

1465

22.0

71/41

0.87

92.5

2930

7.7

30.0

95.5/55

0.89

92.9

2945

7.8

Electrical data, 2-pole

3x380-415/660-690 V

Motor
[kW]

I1/1 [A]

Cos 1/1

[%]

n [min-1]

2.2

4.45

0.89-0.87

87.5-87.5

2890-2910

IStart
----------------I 1/1
-

3.0

5.95

0.88-0.85

88-88

2910-2930

4.0

0.88-0.84

89-89

2910-2930

5.5

11.2

0.88-0.84

90-90

2910-2930

7.5

15.2

0.87-0.80

89.5-89.5

2900-2920

11.0

21/12.2

0.86

90.7

2930

7.3

15.0

28/16.2

0.86

91.6

2930

7.6

18.5

34.5/20

0.86

92

2930

7.9

22.0

41/23.6

0.87

92.5

2930

7.7

30.0

55/32

0.89

93.1

2945

7.8

37.0

68/39.5

0.89

93.6

2950

7.6

55.0

99/57

0.89

94.3

2955

7.7

75.0

132/76

0.9

94.9

2975

7.5

90.0

161/93

0.89

95.2

2975

7.5

110.0

200/116

0.85

95

2980

7.7

132.0

235/136

0.88

95.5

2980

6.8

160.0

280/162

0.9

95.9

2980

7.2

200.0

347/201

0.91

96.3

2980

7.8

250.0

415

0.9

96.2

2979

35

Motors for TP pumps

Electrical data, 4-pole

3x380-415/660-690 V

TP, TPD, TPE, TPED

Electrical data, motors with builtin frequency converter

Motor
[kW]

I1/1 [A]

Cos 1/1

[%]

n [min-1]

2.2

5.2/3

0.71

86.4

1450

IStart
----------------I 1/1
6

3.0

6.5/3.8

0.77

87.4

1440

6.3

Motor [kW]

I1/1 [A]

4.0

8.5/4.9

0.77

88.3

1450

6.1

0.37

2.7-2.5

5.5

11.3/6.5

0.84

89.2

1450

7.4

0.55

3.9-3.6

7.5

15/8.7

0.84

90.1

1450

7.4

0.75

5.1-4.7

11.0

22.5/13

0.82

91

1460

6.9

1.1

7.1-6.6

15.0

29.5/17

0.84

91.8

1460

7.4

Electrical data, 2-pole

18.5

36/21

0.84

92.2

1460

7.5

22.0

42.5/24.5

0.85

92.6

1465

7.8

30.0

58.5/34

0.84

93.2

1465

37.0

70.5/41

0.84

93.6

1475

7.7

45.0

84.5/49

0.86

93.9

1475

7.7

55.0

107/62

0.82

94.2

1475

6.8

75.0

140/81

0.85

94.7

1485

6.8

90.0

168/97

0.85

1480

110.0

208/120

0.85

1480

132.0

239/138

0.86

1485

160.0

288/166

0.88

1485

200.0

359/208

0.89

1485

250.0

425/245

0.88

1488

315.0

540/312

0.88

1488

355.0

610/350

0.87

1488

400.0

690/400

0.87

1488

Motor [kW]

I1/1 [A]
21.4

Electrical data, 2-pole

3x380-480 V, 2900 min-1

Motor [kW]

I1/1 [A]

0.75

2.0-1.8

1.1

2.6-2.3

1.5

3.3-2.7

2.2

4.6-3.8

3.0

6.2-5.0

4.0

8.1-6.6

5.5

11.0-8.8

7.5

15.0-12.0

Electrical data, 2-pole

3x380-415 V, 2900 min-1

500.0

850/490

0.88

1488

11.0

560.0

950/550

0.88

1492

15.0

28.0

630.0

1060/610

0.88

1492

18.5

34.0

22.0

42.0

Electrical data, 6-pole

3x220-240/380-415 V
Electrical data, 4-pole

1.5

7.6/4.4

0.71

72

930

IStart
----------------I 1/1
3.7

2.2

9.4/5.4

0.72

80

940

4.4

Motor
[kW]

I1/1 [A]

Cos 1/1

[%]

n [min-1]

3.0

12.3/7.1

0.75

83.7

955

5.8

4.0

15.9/9.2

0.76

84.9

955

6.2

5.5

21.5/12.5

0.77

85.2

955

6.2

7.5

27.5/15.9

0.82

87.7

965

5.9

Electrical data, 6-pole

3x380-415/660-690 V

2.2

5.4/3.1

0.72

82

940

IStart
----------------I 1/1
4.4

3.0

7.1/4.1

0.75

83.7

955

5.8

Motor
[kW]

36

1x220-240 V, 2900 min-1

I1/1 [A]

Cos 1/1

[%]

n [min-1]

4.0

9.2/5.3

0.76

84.9

955

6.2

5.5

12.5/7.2

0.77

85.2

955

6.2

7.5

15.9/9.2

0.82

87.7

965

5.9

1 x 220-240 V, 1450 min-1

Motor [kW]

I1/1 [A]

0.37

2.8-2.6

0.55

4.0-3.6

0.75

5.3-4.85

Electrical data, 4-pole

3x380-480 V, 1450 min-1

Motor [kW]

I1/1 [A]

0.75

1.8-1.9

1.1

2.5-2.2

1.5

3.3-2.9

2.2

4.6-3.8

3.0

6.2-5.0

4.0

8.1-6.6

Electrical data, 4-pole

3x380-415 V, 1450 min-1

Motor [kW]

I1/1 [A]

5.5

11.3-10.5

7.5

14.7

11.0

21.7

15.0

28.5

18.5

34.7

22.0

41.0

Installation

TP, TPD, TPE, TPED

Mechanical installation
TP, TPD, TPE, TPED pumps up to and including 7.5 kW
can be installed in horizontal and vertical pipes.

When installing a twin-head pump in a horizontal pipe


and with horizontal shaft, fit the upper pump housing
with an automatic air vent.
Twin-head pump housings have two Rp 1/4 tappings
(TP Series 200) or four Rp 1/8 tappings (TP Series 300)
for mounting of automatic air vents.

TM00 3734 0897

TM02 7533 3703

Sing

Fig. 16 Installation of motor sizes up to and including


7.5 kW

Fig. 18 Tappings for mounting of automatic air vents in TP


Series 200 and TP Series 300

TP, TPD, TPE, TPED pumps larger than 7.5 kW can


only be installed in horizontal pipes.

For further information about identification of TP Series


200 and TP Series 300 models, see page 22 to
page 24.

Cooling

Sing
TM00 3735 0897

To ensure sufficient cooling of motor and electronics,


observe the following:

Fig. 17 Installation of motor sizes larger than 7.5 kW

Place the pump in such a way that sufficient cooling


is ensured.
Make sure that the temperature of the cooling air
does not exceed +40C.
Keep the motor cooling fins, holes in fan cover and
fan blades clean.

Note: The motor must never point downwards.

Make sure the frequency for the motor is at least


6 Hz (12 % of max. speed).

Install the pumps in such a way that strain from the


pipework is not transferred to the pump housing.

Condensation cover for TPE pumps

Pumps with motors of 11 kW can only be installed in


horizontal pipes with the motor placed in vertical position. Always install the pump on an even and rigid foundation.

When installing TPE pumps outdoors, provide the


motor with a suitable cover to avoid condensation on
the electronic components and to protect the pump and
motor against the direct effects of the elements.
When mounting the condensation cover on top of the
motor, make sure to leave enough space for the air to
cool the motor.

Sing

TM03 0372 5004

Pumps with motors up to 11 kW may be suspended


direct in the pipes, provided the pipework can support
the pump. If not, install the pump on a mounting bracket
or base plate.

Fig. 19 MGE and MMGE motors with condensation cover

37

Installation

TP, TPD, TPE, TPED

Elimination of noise and vibrations

Expansion joints

In order to achieve optimum operation and minimum


noise and vibration, consider vibration dampening of
the pump. Generally, always consider this for pumps
with motors above 11 kW. Smaller motor sizes,
however, may also cause undesirable noise and vibration.

Install expansion joints to

Noise and vibration are generated by the revolutions of


the motor and pump and by the flow in pipes and
fittings. The effect on the environment is subjective and
depends on correct installation and the state of the
remaining system.
Elimination of noise and vibrations is best achieved by
means of a concrete foundation, vibration dampers and
expansion joints.

Expansion joint

Concrete
foundation

absorb expansions/contractions in the pipework


caused by changing liquid temperature
reduce mechanical strains in connection with pressure surges in the pipework
isolate mechanical structure-borne noise in the
pipework (only rubber bellows expansion joints).
Note: Do not install expansion joints to compensate for
inaccuracies in the pipework such as centre displacement of flanges.
Fit expansion joints at a distance of minimum 1 to 1
times the nominal flange diameter away from the pump
on the suction as well as on the discharge side. This will
prevent the development of turbulence in the expansion
joints, resulting in better suction conditions and a
minimum pressure loss on the pressure side. At high
water velocities (> 5 m/s) we recommend you to install
larger expansion joints corresponding to the pipework.

Vibration dampers

TM02 4993 2102

TM02 4979 1902 - TM02 4981 1902

The illustration below shows examples of rubber


bellows expansion joints with or without limit rods.

Fig. 20 Foundation of TP pump

Concrete foundation
Install the pump on a plane and rigid concrete foundation. This is the optimum solution for vibration dampening. As a rule of thumb, the weight of a concrete
foundation should be 1.5 times the pump weight.
Vibration dampers
To prevent the transmission of vibrations to buildings,
we recommend you to isolate the pump foundation from
building parts by means of vibration dampers.
The selection of the right vibration damper requires the
following data:
forces transmitted through the damper
motor speed considering speed control, if any

Fig. 21 Examples of rubber bellows expansion joints

Expansion joints with limit rods can be used to reduce


the effects of the expansion/contraction forces on the
pipework. We always recommend expansion joints with
limit rods for flanges larger than DN 100.
Anchor the pipes in such a way that they do not stress
the expansion joints and the pump. Follow the
suppliers instructions and pass them on to advisers or
pipe installers.
The illustration below shows an example of a metal
bellows expansion joint with limit rods.

required dampening in % (suggested value is 70%).

If you install the pump on a foundation with vibration


dampers, always fit expansion joints on the pump
flanges. This is important to prevent the pump from
"hanging" in the flanges.

TM02 4980 1902

Which is the right damper varies from installation to


installation, and a wrong damper may increase the
vibration level. Vibration dampers should therefore be
sized by the supplier.

Fig. 22 Example of metal expansion joint

Due to the risk of rupture of the rubber bellows, metal


bellows expansion joints may be preferred at temperatures above +100C combined with high pressure.

38

Installation

TP, TPD, TPE, TPED

Terminal box positions

TPED pumps with terminal boxes in position 10:30 and 13:30


Single-phase

[kW]

Three-phase

[kW]

As standard, the terminal boxes of TP and TPE pumps


are mounted in position 9 oclock.
The possible terminal box positions are shown below.

TPED 32-60/2

0.37

TPED 32-230/2

0.75

TPED 32-120/2

0.37

TPED 32-200/2

1.1

TPED 40-60/2

0.37

TPED 32-250/2

1.5

TPED 40-120/2

0.37

TPED 32-320/2

2.2

TPED 50-60/2

0.37

TPED 32-380/2

3.0

TPED 32-30/4

0.37

TPED 32-460/2

4.0

TPED 40-30/4

0.37

TPED 32-580/2

5.5

TPED 50-30/4

0.37

TPED 40-190/2

0.75

TPED 40-230/2

1.1

TPED 40-270/2

1.5

TPED 40-240/2

2.2

TPED 40-300/2

3.0

TPED 40-360/2

4.0

TPED 40-470/2

5.5

Stellung 3
Position
3 oclock

Stellung 6
Position
6 oclock

Stellung 9
Position
9 oclock
Standard

Stellung 12
Position
12 oclock

TM03 0565 2005

TP single-head pumps

Fig. 23 Possible terminal box positions

Note: Due to the motor construction the terminal boxes


of some TP pumps with motor sizes above 250 kW are
mounted in position 10.30.
TPD twin-head pumps

B4

B4

TM02 8630 0604

As standard, the terminal boxes of all TPD and most


TPED pumps are mounted in position 12 oclock, see
above. The TPED pumps with terminal boxes in position 10.30 and 13.30 are listed in the table on the right.

TPED 40-580/2

7.5

TPED 50-120/2

0.75

TPED 50-180/2

0.75

TPED 50-160/2

1.1

TPED 50-190/2

1.5

TPED 50-240/2

2.2

TPED 50-290/2

3.0

TPED 50-360/2

4.0

TPED 50-430/2

5.5

TPED 65-120/2

1.1

TPED 65-180/2

1.5

TPED 65-190/2

2.2

TPED 65-230/2

3.0

TPED 65-260/2

4.0

TPED 65-340/2

5.5

TPED 65-410/2

7.5

TPED 65-90/4

0.75

TPED 80-210/2

4.0

TPED 80-240/2

5.5

TPED 80-60/4

0.75

Fig. 24 Terminal box positions of TPED pumps

Note: The B4 dimension can be seen in the tables of


technical data of the individual pump, see the sections
on performance curves and technical data.

39

Installation

TP, TPD, TPE, TPED

Electrical installation

Protection against voltage peaks

Electrical connection

If you use speed controllers or frequency converters of


other makes than Grundfos, you may have the following
problems:

Carry out electrical connection and protection in


accordance with local regulations.

increased motor noise

The pump must be connected to an external mains


switch with a minimum contact gap of 3 mm in all
poles.

detrimental voltage peaks

Electronically speed-controlled pumps must always


be correctly earthed.
Note: The 4.0 - 22 kW motors must be connected to
especially reliable/sturdy earth connections to avoid
earth leakage currents above 3.5 mA.

Pumps with voltage peaks exceeding 650 V (maximum


value) must therefore be protected. The voltage
increase rate dU/dt must not exceed 500 Vs. Noise
and detrimental voltage peaks can be prevented by fitting an LC filter between the speed controller and the
motor.

Single-phase standard motors incorporate a thermal


switch and require no additional motor protection.
Three-phase motors must be connected to a motor
starter.
Motors as from 3 kW incorporate thermistors (PTC).
The thermistors are designed according to
DIN 44 082.
When the pump is switched on via the mains, the
pump will start after approx. 5 seconds.

additional motor losses.

Communication cables for TPE, TPED


Use screened cables (min. 0.5 mm2) for external on/off
switch, digital input, sensor and and setpoint signals.
The screens of the cables should be connected to
frame at both ends.
The screen of the cable must have good frame connection which must be as close as possible to the terminals.

Note: Carry out the mains connection of the pump as


shown in the diagram inside the terminal box cover.
TM02 1325 0901

Screen

Protection
Protection against fault currents
If the pump is connected to an electric installation
where an earth leakage circuit breaker (ELCB) is used
as additional protection, the earth leakage circuit
breaker must be marked with the following symbols.
Single-phase:

The earth leakage circuit breaker must trip out


when earth fault currents with DC content
(pulsating DC) occur.
Three-phase:

The earth leakage circuit breaker must trip out


when earth fault currents with DC content (pulsating
DC) and smooth DC earth fault currents occur.

40

Fig. 25 External start/stop cable connection of TPE,


TPED

Use a screened 2-core cable for the bus connection.


Connect the screen to terminal Y at both ends.

Screen

Fig. 26 bus connection of TPE, TPED

TM02 1343 1001

Do not start the pump until it has been filled with liquid
and vented.

Installation

TP, TPD, TPE, TPED

Group 2

See the wiring diagrams for instructions how to connect


external potential-free contacts for start/stop and digital
function, external setpoint signal and fault signal.
NC C NO

L1 L2 L3

Group 3

Wiring diagram, three-phase, 0.75 - 7.5 kW

Other connections, TPE, TPED

Connect the wires to the following terminal groups:


Group 1: Inputs (external start/stop, digital function,
setpoint and sensor signals, terminals 1-9
and bus connection, A, Y, B).
All inputs are separated from the mains
conducting parts by reinforced insulation.
Group 2: Output (signal relay).
0-10 V
0/4-20 mA

4-20 mA

Group 1

The output, terminals C, NO and NC, are


galvanically separated from other circuits.
Therefore, the supply voltage or protective
extra-low voltage can be connected to the
output as desired.

1/0

1 9 8 7

B Y A

Group 3: Mains supply.


STOP

0/4-20 mA

As a precaution, separate the wires from each other


by reinforced insulation in their entire lengths.

TM02 8414 5103

RUN

Note:
0-10 V

10K

6 5 4 3 2

If no external on/off switch is connected, maintain


the connection across terminals 2 and 3.
Fig. 28 Wiring diagram, three-phase TPE pumps

Wiring diagram, single-phase

Wiring diagram, three-phase, 11 - 22 kW

N PE L

A: RS-485A
Y: Screen
B: RS-485B

0-10 V
0/4-20 mA

Group 3

8: +24 V
7: Sensor input
6: GND (frame)
5: +5 V
4: Setpoint input
3: GND (frame)
2: Start/stop
1: Digital input

4-20 mA

Group 1

NC C NO

Group 3

Mains connection

Group 2

Signal relay

STOP
RUN

NO
O

10K

6 5 4 3 2

Fig. 27 Wiring diagram, single-phase TPE pumps

TM02 1952 2601

0-10 V

TM02 0795 0101

0/4-20 mA

NC

B Y A

Group 1

1 9 8 7

Group 2

0/1

Fig. 29 Wiring diagram, three-phase TPE, TPED pumps

41

Flanges for TP pumps

TP, TPD, TPE, TPED

Flange dimensions
PN 6 and PN 10 flanges
EN 1092-2 PN 6 (0.6 MPa)

D1

TM02 7720 3803

S
D2
D3

EN 1092-2 PN 10 (1.0 MPa)

Nominal diameter (DN)


D1

Nominal diameter (DN)

32

40

50

65

80

100

32

40

50

65

80

100

125

150

200

250

32

40

50

65

80

100

32

40

50

65

80

100

125

150

200

250

D2

90

100

110

130

150

170

100

110

125

145

160

180

210

240

295

350

D3

120

130

140

160

190

210

140

150

165

185

200

220

250

285

340

395

4x14

4x14

4x14

4x14

4x19

4x19

4x19

4x19

4x19

4x19

8x19

8x19

8x19

8x23

8x23 12x23

PN 16 and PN 25 flanges
EN 1092-2 PN 16 (1.6 MPa)

D1

S
TM02 7720 3803

32

D2
D3

40

50

65

Nominal diameter (DN)


125

150

65

80

100

125

150

200

250

300

32

40

50

65

80

100

125

150

65

80

100

125

150

200

250

300

100

110

125

145

160

180

210

240

145

160

190

220

250

310

370

430

360

425

485

D3

140

150

165

185

200

220

250

285

185

200

235

270

300

4x19

4x19

4x19

4x19

8x19

8x19

8x19

8x23

8x19

8x19

8x23

8x28

8x28 12x28 12x31 16x31

EN/DIN 2635 PN 40
(4.0 MPa)

Nominal diameter (DN)


TM02 7720 3803

100

D2

D1

42

80

D1

PN 40 flanges

D2
D3

EN 1092-2 PN 25 (2.5 MPa)

Nominal diameter (DN)

400

500

D1

400

500

D2

585

585

D3

660

660

16x42

20x42

Curve charts

TP, TPD, TPE, TPED

How to read the curve charts


H
[m]
60

TP, TPE 32

-580/2

50 Hz

55
50

Pump type and


frequency

-460/2

45
40

-380/2

35

-320/2

QH curve for the individual single-head pump.


The bold curve indicates the recommended
performance range.

30
-250/2

25

-200/2

20
15
10
0

12

16

20

24

P2
[kW]
6

Q [m/h]

-580/2

5
-460/2

4
3

-380/2

The power curve indicates pump


input power [P2].

-320/2

-250/2
-200/2

1
0
0

12

16

20

24

Q [m/h]

12

16

20

24

Q [m/h]

NPSH
[m]
16
12
8
4
0
Eta
[%]
60

-200/2

-250/2

-320/2

55

-380/2
-580/2

50
-460/2

45

The eta curve shows


the pump efficiency.

40
35
30
4

12

16

20

24

Q [m/h]

Q [l/s]

v [m/s]

TM02 5017 2102

43

Curve charts

Curve conditions
The guidelines below apply to the curves shown on the
following pages:
1. Tolerances to ISO 9906, Annex A.
2. The curves apply to the performance of singlehead, three-phase pumps. For other pump versions, please see the exact curves in WinCAPS or
WebCAPS. For other pump versions, the performance may differ for the following reasons:
- The valve in twin-head pumps may cause losses
- Single-phase motors run at lower speed
- E-motors run at lower speed.
3. QH curves of the individual single-head pumps are
shown with expected speed of a three-phase standard motor. For further information, see the tables of
technical data on the following pages.
The performance of the single-phase motor is
slightly reduced. Please refer to WinCAPS or WebCAPS for the extact single-phase curves.
4. Curves of TPE Series 1000 pumps and TPE Series
2000 pumps and TPE pumps without pressure sensor are shown as max. curves (100% curves) only.
Please refer to WinCAPS for the extact curves.
5. Measurements have been made with airless water
at a temperature of +20C.
6. The curves apply to a kinematic viscosity of
= 1 mm2/s (1 cSt).
7. Due to the risk of pump overheating, do not use the
pumps below the minimum flow rate indicated by
the bold-faced curves.
Note: We do not recommend constant operation at
a flow rate below 10%.
8. If the pumped liquid density and/or viscosity is
higher than that of water, it may be necessary to use
a motor with a higher performance.

44

TP, TPD, TPE, TPED

45

Performance curves

G 1
2-pole, PN 6/10/16

TP, TPD, TPE, TPED, 2-pole, PN 6/10/16


TP, TPE 25-XX /2 R
H
[m]

TP, TPE 25

-90/2 R

50 Hz

8
7
6

-50/2 R

5
4
3
2
1
0

8 Q [m/h]

P2
[kW]
0.20
0.16

-90/2 R

0.12
0.08

-50/2 R

0.04
0.00
0

8 Q [m/h]

4
-50/2 R, -90/2 R

3
2
1

technical data

NPSH
[m]

0
0

8 Q [m/h]

Eta
[%]
50

-90/2 R

35

-50/2 R

30
25
20
0
0.0
0

46

2
0.5
1

4
1.0

1.5
2

2.0
3

8 Q [m/h]
Q [l/s]
4 v [m/s]

TP, TPD, TPE, TPED, 2-pole, PN 6/10/16

40

TM02 5014 0504Performance

curves,

45

Technical data

G 1
2-pole, PN 6/10/16

B4

B4
AC
AC

H1

H2

H3
H3

AD
AD

L1

AE

AF

TM02 8348 5004

B1 B2

Technical data
TP 25

-50/2 R

-90/2 R

TPD

TPE

TPED

Series

100

100

1-phase TP

63

71

3-phase TP

63

63

1-phase TPE

71

71

IEC size

3-phase TPE
P2

1-/3-phase TP

[kW] 0.12/0.12 0.25/0.25

1-/3-phase TPE [kW]

PN
Tmin ; Tmax

AC
AD

10

[-25;110] [-25;110]
G1

G1

[mm]

118/118

139/118

1-/3-phase TPE [mm]


1-/3-phase TP

0.37/-

10
[C]

G
1-/3-phase TP

0.37/-

141/-

[mm] 101/101

141/111/101

1-/3-phase TPE [mm]

140/-

140/-

AE

1-/3-phase TPE [mm]

105/-

105/-

AF

1-/3-phase TPE [mm]

105/-

105/-

B1

[mm]

54

54

B2

[mm]

52

52

[mm]

101/-

111/-

1-/3-phase TPE [mm]

B4

1-/3-phase TP

140/-

140/-

L1

[mm]

180

180

H1

[mm]

25

25

H2

[mm]

118

118

H3

1-/3-phase TP

[mm] 323/323

1-/3-phase TPE [mm]

334/-

353/323
334/-

47

Performance curves

G2
2-pole, PN 6/10/16

TP, TPE 32-XX/2


H
[m]
9

TP, TPE 32

-90/2 R

50 Hz

8
7
6

-50/2 R

5
4
3
2
1
0

9Q [m/h]

P2
[kW]
-90/2 R

0.20
0.16
0.12

-50/2 R

0.08
0.04
0.00
0

NPSH
[m]
3.0

9Q [m/h]
-90/2 R

2.5
2.0
1.5
1.0
-50/2 R

0.5
0.0
0

9Q [m/h]

Eta
[%]
55
50

-90/2 R

45
40

-50/2 R

35
30
25
20

48

9Q [m/h]

0.0

0.5

1.0

1.5

2.0

2.5 Q [l/s]

0.0

0.5

1.0

1.5

2.0

2.5 v [m/s]

TM02 5015 0504

Technical data

G2
2-pole, PN 6/10/16

B4

B4
AC
AC

H1

H2

H3
H3

AD
AD

L1

TM02 8348 5004

AE

AF

B1 B2

Technical data
TP 32

-50/2 R

-90/2 R

TPD

TPE

TPED

Series

100

100

1-phase TP

63

71

3-phase TP

63

63

1-phase TPE

71

71

3-phase TPE

IEC size

P2

1-/3-phase TP

[kW] 0.12/0.12 0.25/0.25

1-/3-phase TPE [kW]

PN
Tmin ; Tmax

AC
AD

10

[-25;110] [-25;110]
G2

G2

[mm]

118/118

139/118

1-/3-phase TPE [mm]


1-/3-phase TP

0.37/-

10
[C]

G
1-/3-phase TP

0.37/-

141/-

[mm] 101/101

141/111/101

1-/3-phase TPE [mm]

140/-

140/-

AE

1-/3-phase TPE [mm]

105/-

105/-

AF

1-/3-phase TPE [mm]

105/-

105/-

B1

[mm]

51

51

B2

[mm]

60

60

[mm]

101/-

111/-

1-/3-phase TPE [mm]

B4

1-/3-phase TP

140/-

140/-

L1

[mm]

180

180

H1

[mm]

40

40

H2

[mm]

118

118

H3

1-/3-phase TP

[mm] 338/338

1-/3-phase TPE [mm]

334/-

368/338
334/-

49

Performance curves

DN 32
2-pole, PN 6/10/16

TP, TPD, TPE, TPED 32-XX/2


H
[m]
24

H
[m]

TP, TPE 32

-230/2

60

50 Hz

22

50
-180/2

16

-150/2
-120/2

10

40

-380/2

35

-320/2

30

8
6
2

15

10
2

9 10 11 Q [m/h]

P2
[kW]
0.7

12

16

-230/2

24

Q [m/h]

-580/2

0.5
-120/2

-150/2

0.3

-460/2

-180/2

0.4

-380/2
-320/2

0.2
-60/2

0.1

-250/2
-200/2

0.0

0
0

9 10 11 Q [m/h]

NPSH
[m]

12

16

20

24

Q [m/h]

12

16

20

24

Q [m/h]

NPSH
[m]
-150/2, -180/2, -230/2

10

16

12

-120/2

-60/2

2
0

0
0

9 10 11 Q [m/h]
Eta
[%]
60

-200/2

-250/2

-320/2

55
-150/2

-380/2
-580/2

50
-60/2
-230/2
-180/2

-460/2

45
-120/2

40
35
30

9 10 11 Q [m/h]

0.0

0.5

1.0

1.5

2.0

2.5

3.0

Q [l/s]

0.0

0.5

1.0

1.5

2.0

2.5

3.0

v [m/s]

12

16

20

24

Q [m/h]

Q [l/s]

v [m/s]

Note: All QH-curves apply to single-head pumps. For further information, see page 44.

TM02 5017 0504

TM02 5016 0504

50

20

P2
[kW]
6

0.6

Eta
[%]
65
60
55
50
45
40
35
30
25
20

-200/2

20

-250/2

25

-60/2

-460/2

45

14
12

50 Hz

55

20
18

TP, TPE 32

-580/2

Technical data

B4

B4
AC

B4
P
AC

P
B3

H3

AD

H3

D1
B2

B1
L1

B2

L1

H4

D1
B1

H4

H1

H1

H2

H2

Rp 1/4

TM02 8632 5004 - TM02 8631 5004

B4
AD
AD

DN 32
2-pole, PN 6/10/16

M
AE

AE

AF

AF

AE

C1

AF

C1

C5

C6

C5

Technical data
TP 32

-60/2

-120/2

-150/2

-180/2

-230/2

-200/2

-250/2

-320/2

-380/2

-460/2

-580/2

TPD

TPE

TPED

Series

200

200

200

200

200

300

300

300

300

300

300

1-phase TP

71

71

71

80

80

3-phase TP

63

71

71

71

80

80

90

90

100

112

132

1-phase TPE

71

71

71

71

80

80

3-phase TPE

90

90

90

90

100

112

132
-/5.5

IEC size

1-/3-phase TP [kW] 0.25/0.18 0.25/0.37 0.37/0.37 0.55/0.55 0.75/0.75

P2

1-/3-phase TPE [kW]

PN
Tmin ; Tmax

AC
AD

-/2.2

-/3

-/4

0.37/-

0.55/-

0.75/0.75

1.1/1.1

-/1.5

-/2.2

-/3

-/4

-/5.5

PN 6/10

PN 6/10

PN 6/10

PN 6/10

PN 6/10

PN 16

PN 16

PN 16

PN 16

PN 16

PN 16

[-25;140] [-25;140] [-25;140] [-25;140] [-25;140] [-25;140] [-25;140] [-25;140] [-25;140] [-25;140] [-25;140]
32

32

32

32

32

32

32

32

32

32

32

[mm]

139/118

141/141

141/141

141/141

141/141

-/178

-/178

-/178

-/198

-/220

-/220

1-/3-phase TPE [mm]


1-/3-phase TP

-/1.5

0.37/-

[C]

D1
1-/3-phase TP

-/1.1

0.37/-

[mm]

141/-

141/-

141/-

141/-

141/178

141/178

-/178

-/178

-/198

-/220

-/220

111/101

133/109

133/109

133/109

133/109

-/110

-/110

-/110

-/120

-/134

-/134

1-/3-phase TPE [mm]

140/-

140/-

140/-

140/-

140/167

140/167

-/167

-/167

-/177

-/188

-/188

AE

1-/3-phase TPE [mm]

105/-

105/-

105/-

105/-

105/132

105/132

-/132

-/132

-/132

-/145

-/145

AF

1-/3-phase TPE [mm]

105/-

105/-

105/-

105/-

105/132

105/132

-/132

-/132

-/132

-/145

-/145

200

200

200

250

250

300

[mm]

B1

[mm]

75/180

75/180

102/222

102/222

102/222

125/260 125/260 125/260 125/260 144/321 144/321

B2

[mm]

75/180

75/180

102/222

102/222

102/222

117/257

117/257

117/257

117/257

B3

[mm]

200

200

240

240

240

276

276

276

276

TP

[mm]

111/180

133/180

133/222

133/222

133/222

125/260 125/260 125/260 125/263 144/321 150/328

1-phase TPE

[mm] 140/275

140/275

140/225

140/225

140/225

140/260

3-phase TPE

[mm]

167/315

167/333 167/333 167/333 177/343 188/398 188/398

C1

[mm]

80/200

80/200

80/240

80/240

80/240

144/356 144/356 144/356 144/356 144/435 144/435

C5

[mm]

110/52

110/52

140/82

140/82

140/82

170/45

B4

144/321 144/321
355
-

355
-

170/45

170/45

170/45

220/46

220/46

C6

[mm]

103

103

103

103

103

175

175

175

175

175

175

L1

[mm]

220

220

280

280

280

340

340

340

340

440

440

H1

[mm]

68

68

79

79

79

100

100

100

100

100

100

H2

[mm]

140

126

125

125

137

154

154

154

183

184

223

385/385

395/395

447/395

447/447

-/535

-/535

-/575

-/618

-/656

-/714

407/-

385/-

395/-

395/-

447/497

505/535

-/535

-/575

-/618

-/656

-/711

M12

M12

M12

M12

M12

M16

M16

M16

M16

M16

M16

2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with

H3
H4

1-/3-phase TP

[mm] 419/388

1-/3-phase TPE [mm]


[mm]

motors as standard.

The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

51

Performance curves

DN 40
2-pole, PN 6/10/16

TP, TPE 40-XX/2


H
[m]
-90/2

TP, TPE 40

H
[m]
28

50 Hz

26
24

TP, TPE 40

-230/2

50 Hz

22

20

-190/2

18

-50/2

16

-180/2

14
12

-120/2

10

-60/2

2
0

Q [m/h]

P2
[kW]

10

12

16

Q [m/h]
-270/2
-230/2

1.0

-90/2

0.16

0.8

0.12

-190/2

0.6

-50/2

0.08

-180/2

0.4

0.04

-120/2
-60/2

0.2

0.00

0.0
0

Q [m/h]

NPSH
[m]
3.0

10

12

14

16

Q [m/h]

NPSH
[m]
-90/2

10

2.5

-190/2, -230/2, -270/2

2.0

-120/2 -180/2

-50/2

1.5

0.5

0.0

0
0

55

Q [m/h]

Eta
[%]
75
70
65
60
55
50
45
40
35
30

-50/2

50
45
40
35

-90/2

30
25
20

0.0
0.0

2
0.5
0.5

4
1.0

5
1.5
1.0

7
2.0
1.5

9
2.5

Q [m/h]
Q [l/s]
2.0 v [m/s]

10

12

14

16

Q [m/h]

-60/2
-120/2
-180/2

-190/2
-270/2
-230/2

0
TM02 5018 0504

-60/2

0
0

10

2
1

12
3

Note: All QH-curves apply to single-head pumps. For further information, see page 44.

14

16

4
3

Q [m/h]
5

Q [l/s]
v [m/s]

TM02 5019 0504

1.0

52

14

P2
[kW]
1.2

0.20

Eta
[%]
60

-270/2

Technical data

B4

B4
AC

B4
P
AC

P
B3

H3

AD

H3

D1
B2

B1
L1

B2

L1

H4

D1
B1

H4

H1

H1

H2

H2

Rp 1/4

M
AE

AE

AF

AF

AE

C1

AF

C1

C5

C6

C5

TM02 8632 5004 - TM02 8631 5004

B4
AD
AD

DN 40
2-pole, PN 6/10/16

Technical data
TP 40

-50/2

-60/2

-90/2

-120/2

-180/2

-190/2

-230/2

-270/2

TPD

TPE

TPED

Series

IEC size

P2

100

200

100

200

200

200

200

200

1-phase TP

63

71

71

71

80

80

90

90

3-phase TP

63

71

63

71

71

80

80

90

1-phase TPE

71

71

71

71

71

80

80

3-phase TPE

90

90

90

1-/3-phase TP [kW] 0.12/0.12 0.25/0.25 0.25/0.25 0.37/0.37 0.55/0.55 0.75/0.75

1.1/1.1

1.5/1.5

1-/3-phase TPE [kW]

PN

0.37/-

0.37/-

0.37/-

0.37/-

0.55/-

0.75/0.75

1.1/1.1

-/1.5

PN 6/10

PN 6/10

PN 6/10

PN 6/10

PN 6/10

PN 16

PN 16

PN 16

Tmin ; Tmax

[C]

D1

[mm]

40

40

40

40

40

40

[mm]

118/118

141/141

139/118

141/141

141/141

141/141

1-/3-phase TP

AC

1-/3-phase TPE [mm]


1-/3-phase TP

AD

[-25;110] [-25;140] [-25;110] [-25;140] [-25;140] [-25;140] [-25;140] [-25;140]

141/-

[mm] 101/101

40

40

178/141 178/178

141/-

141/-

141/-

141/-

141/178

141/178

-/178

133/109

111/101

133/109

133/109

133/109

139/109

139/110

1-/3-phase TPE [mm]

140/-

140/-

141/-

140/-

141/-

140/167

140/167

-/167

AE

1-/3-phase TPE [mm]

105/-

105/-

105/-

105/-

105/-

105/132

105/132

132

AF

1-/3-phase TPE [mm]

105/-

105/-

105/-

105/-

105/-

105/132

105/132

132

[mm]

B1

[mm]

75/-

75/180

75/-

75/180

100/-

102/222

102/222 102/222

B2

[mm]

75/-

75/180

75/-

75/180

100/-

102/222

102/222 102/222

B3

[mm]

200

200

240

TP

[mm]

101/-

133/180

111/-

133/180

133/-

133/222

139/222 139/222

1-phase TPE

[mm] 140/275

140/275

141/275

140/275

141/225

140/225

140/225

3-phase TPE

[mm]

167/315

167/315 167/315

C1

[mm]

-/-

80/200

-/-

80/200

80/-

120/240

120/240 120/240

C5

[mm]

-/-

125/45

-/-

125/45

125/-

160/95

160/95

B4

240

240
-

160/95

C6

[mm]

125

125

125

125

125

L1

[mm]

250

250

250

250

250

320

320

320

H1

[mm]

55

67

55

67

68

68

68

68

H2

[mm]

118

129

118

129

131

141

141

151

387/366

383/353

387/387

442/390

439/439

499/490 539/500

364/-

395/-

364/-

388/-

390/-

320/490

439/490

M12

M12

M12

M12

M12

M12

2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with

H3
H4

1-/3-phase TP

[mm] 353/353

1-/3-phase TPE [mm]


[mm]

-/500

motors as standard.

The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

53

Performance curves

DN 40
2-pole, PN 6/10/16

TP, TPD, TPE, TPED 40-XX/2


H
[m]

TP, TPE 40

-580/2

60

50 Hz

55
50

-470/2

45
40

-360/2

35

-300/2

30

-240/2

25
20
15
10
P2
[kW]
8

12

16 20 24 28

32

Q [m/h]

-580/2

7
6
-470/2

5
4

-360/2

-300/2
-240/2

2
1
0
0

12

16 20 24 28

32

Q [m/h]

NPSH
[m]
10
-300/2, 360/2, 470/2, 580/2

8
6

-240/2

4
2
0
0

12

Eta
[%]
60

16 20 24 28

32

Q [m/h]

-300/2
-360/2

55

-240/2

50
-470/2

45

-580/2

40
35
30

0
0

12

16 20 24 28
4

6
4

32

8
6

Q [m/h]
10 Q [l/s]
v [m/s]

TM02 5020 0504

Note: All QH-curves apply to single-head pumps. For further information, see page 44.

54

Technical data

B4

B4
AC

B4
P
AC

P
B3

H3

AD

H3

B1
L1

B2

D1
B2

L1

H4

D1
B1

H4

H1

H1

H2

H2

Rp 1/4

M
AE

AF

AE

AF

AE

C1

AF

C1

C5

C6

C5

TM02 8632 5004 - TM02 8631 5004

B4
AD
AD

DN 40
2-pole, PN 6/10/16

Technical data
TP 40

-240/2

-300/2

-360/2

-470/2

-580/2

TPD

TPE

TPED

Series

300

300

300

300

300

IEC size

P2

1-phase TP

3-phase TP

90

100

112

132

132

1-phase TPE

3-phase TPE

90

100

112

132

132

1-/3-phase TP [kW]

-/2.2

-/3

-/4

-/5.5

-/7.5

1-/3-phase TPE [kW]

-/2.2

-/3

-/4

-/5.5

-/7.5

PN 16

PN 16

PN 16

PN 16

PN 16

PN
Tmin ; Tmax

[C]

D1

[mm]

40

40

40

40

40

[mm]

-/178

-/198

-/220

-/220

-/220

1-/3-phase TPE [mm]

-/178

-/198

-/220

-/220

-/220

1-/3-phase TP

[mm]

-/110

-/120

-/134

-/134

-/134

1-/3-phase TP

AC
AD

[-25;140] [-25;140] [-25;140] [-25;140] [-25;140]

1-/3-phase TPE [mm]

-/167

-/177

-/188

-/188

-/188

AE

1-/3-phase TPE [mm]

132

132

145

145

145

AF

1-/3-phase TPE [mm]

132

132

145

145

145

[mm]

200

250

250

300

300

B1

[mm] 130/273 130/273 130/273 149/325 149/325

B2

[mm] 117/267

B3

[mm]
TP

B4

290

117/267

117/267

290

290

144/321 144/321
355

355

[mm] 130/273 130/273 134/273 150/328 150/328

1-phase TPE

[mm]

3-phase TPE

[mm] 167/340 177/350 188/365 188/398 188/398

C1

[mm] 144/400 144/400 144/400 144/435 144/435

C5

[mm]

170/45

170/45

170/45

220/108 220/108

C6

[mm]

175

175

175

175

175

L1

[mm]

340

340

340

440

440

H1

[mm]

100

100

100

110

110

H2

[mm]

166

194

194

225

225

[mm]

-/587

-/629

-/666

-/726

-/726

1-/3-phase TPE [mm]

-/587

-/629

-/666

-/723

-/723

M16

M16

M16

M16

M16

2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with

H3
H4

1-/3-phase TP

[mm]

motors as standard.

The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

55

Performance curves

DN 50
2-pole, PN 6/10/16

TP, TPD, TPE, TPED 50-XX/2


H
[m]

TP, TPE 50

-290/2

28

50 Hz

24

-240/2

20

-190/2
-160/2

16

-180/2

12

-120/2

-60/2

4
0
0

12

16 20 24 28

32

Q [m/h]

P2
[kW]
3.0

-290/2

2.5
2.0

-240/2

1.5

-190/2
-160/2

1.0

-180/2
-120/2
-60/2

0.5
0.0
0

12

16 20 24 28

32

Q [m/h]

NPSH
[m]
10
-180/2

8
6

-60/2
-120/2

4
2
-160/2, -190/2, 240/2, -290/2

0
0

12

16 20 24 28

32

Q [m/h]

-180/2

-240/2
-190/2

-290/2

-160/2
-60/2
-120/2

0
0
0

8
2
1

12

16 20 24 28
4

6
2

32

8
3

Q [m/h]
10 Q [l/s]

v [m/s]

TM02 5021 0504

Eta
[%]
75
70
65
60
55
50
45
40
35
30

Note: All QH-curves apply to single-head pumps. For further information, see page 44.

56

Technical data

B4

B4
AC

B4
P
AC

P
B3

H3

AD

H3

D1
B2

B1
L1

B2

L1

H4

D1
B1

H4

H1

H1

H2

H2

Rp 1/4

M
AE

AF

AE

AF

AE

C1

AF

C1

C5

C6

C5

TM02 8632 5004 - TM02 8631 5004

B4
AD
AD

DN 50
2-pole, PN 6/10/16

Technical data
TP 50

-60/2

-120/2

-180/2

-160/2

-190/2

-240/2

-290/2

TPD

TPE

TPED

Series

200

200

200

300

300

300

300

1-phase TP

71

80

80

3-phase TP

71

80

80

80

90

90

100

1-phase TPE

71

80

80

80

3-phase TPE

90

90

90

90

90

100
-/3

IEC size

1-/3-phase TP [kW] 0.25/0.37 0.55/0.75 0.75/0.75

P2

1-/3-phase TPE [kW]

PN

0.37/PN 6/10

Tmin ; Tmax

[C]

D1

[mm]
1-/3-phase TP

AC

1-/3-phase TP

AD

-/1.5

-/2.2

1.1/1.1

-/1.5

-/2.2

-/3

PN 6/10

PN 16

PN 16

PN 16

PN 16

PN 6/10

[-25;140] [-25;140] [-25;140] [-25;140] [-25;140] [-25;140] [-25;140]


50

[mm] 141/141

1-/3-phase TPE [mm]

-/1.1

0.75/0.75 0.75/0.75

141/-

[mm] 133/109

50

50

50

50

50

50

141/141

141/141

-/178

-/178

-/178

-/198
-/198

141/178

141/178

141/178

-/178

-/178

133/109

133/109

-/110

-/110

-/110

-/120

1-/3-phase TPE [mm]

140/-

140/167

140/167

140/167

-/167

-/167

-/177

AE

1-/3-phase TPE [mm]

105/-

105/-

132

105/132

132

132

132

AF

1-/3-phase TPE [mm]

105/-

105/-

132

105/132

132

132

132

[mm]

200

200

200

250

B1

[mm]

95/180

100/225

100/225

117/252

117/252

117/252

117/252

B2

[mm]

83/190

100/225

100/225

117/252

117/252

117/252

117/252

B3

[mm]

200

240

240

270

270

270

270

133/225

133/225

117/252

117/252

117/252

125/260

B4

TP

[mm] 133/180

1-phase TPE

[mm] 140/275

140/225

140/225

140/252

3-phase TPE

[mm]

167/315

167/315

167/330 167/330 167/330 177/340

C1

[mm] 120/200

120/240

120/240

144/350 144/350 144/350 144/350

C5

[mm]

140/60

140/60

170/60

140/60

170/60

170/60

170/60

C6

[mm]

125

126

126

175

175

175

175

L1

[mm]

280

280

280

340

340

340

340

H1

[mm]

75

75

75

115

115

115

115

H2

[mm]

137

135

135

152

152

152

180

441/441

441/441

-/548

-/548

-/588

-/630

442/491

441/491

518/548

-/548

-/588

-/630

H3
H4

1-/3-phase TP

[mm] 403/403

1-/3-phase TPE [mm]


[mm]

403/-

M12

M12

M12

M16

M16

M16

M16

2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with

motors as standard.

The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

57

Performance curves

DN 50
2-pole, PN 6/10/16

TP, TPD, TPE, TPED 50-XX/2


H
[m]

TP, TPE 50

-900/2

90

50 Hz

-830/2

80
-710/2

70
60

-570/2

50

-440/2

40

-430/2

30

-360/2

20
0

10

20

30

40

50

60

70 Q [m/h]

P2
[kW]
24

-900/2

20

-830/2

16

-710/2

12

-570/2

-440/2
-430/2
-360/2

4
0
0

10

20

30

40

50

60

70 Q [m/h]

10

20

30

40

50

60

70 Q [m/h]

NPSH
[m]
14
12
10
8
6
4
2
0
Eta
[%]
70

-430/2

65

-900/2

60

-710/2 -830/2

-360/2

55

-440/2 -570/2

50
45
40
35
30
10

20

0
0

30

5
2

40

50

10
4

60

70 Q [m/h]

15
6

20
8

Q [l/s]
v [m/s]

TM02 5022 0504

Note: All QH-curves apply to single-head pumps. For further information, see page 44.

58

Technical data

B4

B4
AC

B4
P
AC

P
B3

H3

AD

H3

B1
L1

B2

D1
B2

L1

H4

D1
B1

H4

H1

H1

H2

H2

Rp 1/4

M
AE

AF

AE

AF

AE

C1

AF

C1

C5

C6

C5

TM02 8632 5004 - TM02 8631 5004

B4
AD
AD

DN 50
2-pole, PN 6/10/16

Technical data
TP 50

-360/2

-430/2

-440/2

-570/2

-710/2

-830/2

-900/2

TPD

TPE

TPED

Series

300

300

300

300

300

300

300

IEC size

P2

1-phase TP

3-phase TP

112

132

132

160

160

160

180

1-phase TPE

3-phase TPE

112

132

132

160

160

160

180

1-/3-phase TP [kW]

-/4

-/5.5

-/7.5

-/11

-/15

-/18.5

-/22

1-/3-phase TPE [kW]

-/4

-/5.5

-/7.5

-/11

-/15

-/18.5

-/22

PN 16

PN 16

PN 16

PN 16

PN 16

PN 16

PN 16

PN
Tmin ; Tmax

[C]

D1

[mm]

50

50

50

50

50

50

50

[mm]

-/220

-/220

-/220

-/335

-/335

-/335

-/366

1-/3-phase TPE [mm]

-/220

-/220

-/220

-/258

-/313

-/313

-/350

1-/3-phase TP

[mm]

-/134

-/134

-/134

-/241

-/241

-/241

-/285

1-/3-phase TPE [mm]

-/188

-/188

-/188

-/389

-/417

-/417

-/439

AE

1-/3-phase TPE [mm]

145

145

145

148

148

148

164

AF

1-/3-phase TPE [mm]

145

145

145

148

148

148

164

[mm]

250

300

300

350

350

350

350

1-/3-phase TP

AC
AD

P
B1
B2

[mm] 133/290 133/290 180/386 180/386 180/386 180/386 180/386

[mm] 119/284

B3

[mm]

B4

[-25;140] [-25;140] [-25;140] [-25;140] [-25;140] [-25;140] [-25;140]

320

119/284
320

164/379 164/379 164/379 164/379 164/379


420

420

420

420

420

TP

[mm] 134/290 150/310 180/386 241/386 241/386 241/386 285/393

1-phase TPE

[mm]

3-phase TPE

[mm] 188/380 188/380 188/386 389/386 417/386 417/386 439/386

C1

[mm] 144/400 144/400 144/500 144/500 144/500 144/500 144/500

[mm]

170/52

170/52

C6

[mm]

175

175

175

175

175

175

175

L1

[mm]

340

340

440

440

440

440

440

H1

[mm]

115

115

115

115

115

115

115

H2

[mm]

189

228

234

264

264

264

264

[mm]

-/676

-/734

-/740

-/882

-/882

-/926

-/981

1-/3-phase TPE [mm]

-/676

-/731

-/737

-/828

-/840

-/878

-/904

35

35

35

35

M16

M16

M16

M16

M16

M16

M16

2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with

C5

H3
H4

1-/3-phase TP

[mm]

220/123 220/123 220/123 220/123 220/123

motors as standard.

The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

59

Performance curves

DN 65
2-pole, PN 6/10/16

TP, TPD, TPE, TPED 65-XX/2


H
[m]
26

-260/2

24

TP, TPE 65
50 Hz

-230/2

22
20

-190/2

18
16

-180/2

14
12

-120/2

10
8
6

-60/2

4
2
0
0

P2
[kW]
4.0

10 15 20 25 30 35 40 45

Q [m/h]
-260/2

3.5
3.0

-230/2

2.5

-190/2

2.0
1.5

-180/2
-120/2

1.0
0.5

-60/2

0.0
0

10 15 20 25 30 35 40 45

Q [m/h]

NPSH
[m]
5

-120/2

4
-180/2

3
2

-60/2

-190/2, -230/2, -260/2

1
0
0

10 15 20 25 30 35 40 45

Q [m/h]

-180/2

-260/2
-190/2

-230/2

-60/2
-120/2

10 15 20 25 30 35 40 45

0.0

0.5

1.0

1.5

8
2.0

10
2.5

12
3.0

Q [m/h]
14 Q [l/s]

3.5

v [m/s]

TM02 5023 0504

Eta
[%]
80
75
70
65
60
55
50
45
40
35

Note: All QH-curves apply to single-head pumps. For further information, see page 44.

60

Technical data

B4

B4
AC

B4
P
AC

P
B3

H3

AD

H3

B1
L1

B2

D1
B2

L1

H4

D1
B1

H4

H1

H1

H2

H2

Rp 1/4

M
AE

AF

AE

AF

AE

C1

AF

C1

C5

C6

C5

TM02 8632 5004 - TM02 8631 5004

B4
AD
AD

DN 65
2-pole, PN 6/10/16

Technical data
TP 65

-60/2

-120/2

-180/2

-190/2

-230/2

-260/2

TPD

TPE

TPED

Series

200

200

200

300

300

300

1-phase TP

80

90

90

3-phase TP

71

80

90

90

100

112

1-phase TPE

71

80

3-phase TPE

90

90

100

112

1-/3-phase TP [kW] 0.55/0.55

1.1/1.1

1.5/1.5

-/2.2

-/3

-/4

1-/3-phase TPE [kW]

1.1/1.1

-/1.5

-/2.2

-/3

-/4

PN 16

PN 16

PN 16

IEC size

P2
PN

0.55/PN 6/10

Tmin ; Tmax

[C]

D1

[-25;140] [-25;140] [-25;140] [-25;140] [-25;140] [-25;140]


65

1-/3-phase TP

AC

[mm] 141/141

1-/3-phase TPE [mm]


1-/3-phase TP

AD

PN 6/10 PN 6/10

141/-

[mm] 133/109

65

65

65

178/141 178/178

65

65

-/178

-/198

-/220

141/178

-/178

-/178

-/198

-/220

139/109

139/110

-/110

-/120

-/134

1-/3-phase TPE [mm]

140/-

140/167

-/167

-/167

-/177

-/188

AE

1-/3-phase TPE [mm]

105/-

132

132

132

132

145

AF

1-/3-phase TPE [mm]

105/-

132

132

132

132

145

200

250

250

[mm]

B1

[mm]

93/195

100/225 100/225 142/298 142/298 142/298

B2

[mm]

93/210

100/225 100/225 124/290 124/290 124/290

B3

[mm]

240

B4

240

240

320

320

320

TP

[mm] 133/195

1-phase TPE

[mm] 140/225

140/225

3-phase TPE

[mm]

167/315 167/315 167/355 177/365 188/380

139/225 139/225 142/298 142/298 142/298


-

C1

[mm] 120/240

120/240 120/240 144/400 144/400 144/400

C5

[mm]

170/63

170/63

170/63

180/65

180/65

180/65

C6

[mm]

153

153

153

175

175

175

L1

[mm]

340

340

340

360

360

360

H1

[mm]

82

82

82

105

105

105

H2

[mm]

145

144

154

172

201

201

517/512 557/507

-/598

-/641

-/678

418/-

462/512

-/517

-/598

-/641

-/678

M12

M12

M12

M16

M16

M16

2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with

H3
H4

1-/3-phase TP

[mm] 468/418

1-/3-phase TPE [mm]


[mm]

motors as standard.

The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

61

Performance curves

DN 65
2-pole, PN 6/10/16

TP, TPD, TPE, TPED 65-XX/2


H
[m]

TP, TPE 65

100

50 Hz

-930/2

90
80

-720/2

70

-660/2

60

-550/2

50

-460/2
-410/2

40

-340/2

30
20
P2
[kW]
32

10 20 30 40 50 60 70 80 90

Q [m/h]
-930/2

28
24

-720/2
-660/2

20
16

-550/2
-460/2

12
8

-410/2
-340/2

4
0
0

10 20 30 40 50 60 70 80 90

Q [m/h]

10 20 30 40 50 60 70 80 90

Q [m/h]

NPSH
[m]
10
8
6
4
2
0

-410/2

-930/2

-340/2
-550/2
-460/2

0
0
0

10 20 30 40 50 60 70 80 90
5

10
2

15
4

20

25
6

-720/2
-660/2

Q [m/h]
Q [l/s]
v [m/s]

TM02 5024 0504

Eta
[%]
75
70
65
60
55
50
45
40
35
30

Note: All QH-curves apply to single-head pumps. For further information, see page 44.

62

Technical data

B4

B4
AC

B4
P
AC

P
B3

H3

AD

H3

B1
L1

B2

D1
B2

L1

H4

D1
B1

H4

H1

H1

H2

H2

Rp 1/4

M
AE

AF

AE

AF

AE

C1

AF

C1

C5

C6

C5

TM02 8632 5004 - TM02 8631 5004

B4
AD
AD

DN 65
2-pole, PN 6/10/16

Technical data
TP 65

-340/2

-410/2

-460/2

-550/2

-660/2

-720/2

-930/2

TPD

TPE

TPED

Series

300

300

300

300

300

300

300

IEC size

P2

1-phase TP

3-phase TP

132

132

160

160

160

180

200

1-phase TPE

3-phase TPE

132

132

160

160

160

180

-/30

1-/3-phase TP [kW]

-/5.5

-/7.5

-/11

-/15

-/18.5

-/22

1-/3-phase TPE [kW]

-/5.5

-/7.5

-/11

-/15

-/18.5

-/22

-/-

PN 16

PN 16

PN 16

PN 16

PN 16

PN 16

PN 16

PN
Tmin ; Tmax

[C]

D1
1-/3-phase TP

AC
AD

[mm]

[-25;140] [-25;140] [-25;140] [-25;140] [-25;140] [-25;140] [-25;140]


65

65

65

65

65

65

65

-/220

-/220

-/335

-/335

-/335

-/366

-/405

1-/3-phase TPE [mm]

-/220

-/220

-/258

-/313

-/313

-/350

-/-

1-/3-phase TP

[mm]

-/134

-/134

-/241

-/241

-/241

-/285

-/327

1-/3-phase TPE [mm]

-/188

-/188

-/389

-/417

-/417

-/439

-/-

AE

1-/3-phase TPE [mm]

145

145

148

148

148

164

AF

1-/3-phase TPE [mm]

145

145

148

148

148

164

[mm]

300

300

350

350

350

350

400

B1

[mm] 142/298 142/298 178/349 178/349 178/349 178/349 178/349

B2

[mm] 124/290 124/290 164/383 164/383 164/383 164/383 164/383

B3

[mm]
TP

B4

320

320

440

440

440

440

440

[mm] 150/310 150/310 241/395 241/395 241/395 285/403 327/423

1-phase TPE

[mm]

3-phase TPE

[mm] 188/380 188/380 389/395 417/395 417/395 439/395

C1

[mm] 144/400 144/400 144/520 144/520 144/520 144/520 144/520

C5

[mm]

180/65

180/65

238/111

238/111

238/111

238/111

238/111
175

C6

[mm]

175

175

175

175

175

175

L1

[mm]

360

360

475

475

475

475

475

H1

[mm]

105

105

125

125

125

125

125

H2

[mm]

239

239

263

263

263

263

263

[mm]

-/735

-/735

-/891

-/891

-/935

-/990

-/1057

1-/3-phase TPE [mm]

-/732

-/732

-/837

-/849

-/887

-/913

-/-

35

35

35

35

35

M16

M16

M16

M16

M16

M16

M16

2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with

H3
H4

1-/3-phase TP

[mm]

motors as standard.

The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

63

Performance curves

DN 80
2-pole, PN 6/10/16

TP, TPD, TPE, TPED 80-XX/2


H
[m]

TP, TPE 80

-240/2

24

H
[m]
70

50 Hz

22

60

-180/2

45

-140/2

14
12

-400/2

40
35

-120/2

10

30

25

20

-330/2
-250/2

15
0

10

20

30

40

50

60

70

80 Q [m/h]

P2
[kW]
32

-240/2

20

40

60

80 100 120 140

-700/2

24
-210/2

2
1

-570/2

20

-520/2

16

-180/2

Q [m/h]

28

5
4
-140/2

12

-120/2

-400/2
-330/2
-250/2

0
NPSH
[m]

-520/2

50

16

P2
[kW]

-570/2

55

18

50 Hz

65

-210/2

20

TP, TPE 80

-700/2

0
0

10

20

30

40

50

60

70

80 Q [m/h]

NPSH
[m]

10

20

40

60

80 100 120 140

Q [m/h]

-520/2, 570/2, 700/2

10
-120/2

-180/2, 210/2, 240/2

-140/2

-330/2, -400/2

0
0

10

20

30

40

50

60

70

80 Q [m/h]

Eta
[%]
80

-210/2

75

20

40

60

80 100 120 140

-180/2

65

70

-240/2

55

55

45

45
40
20

30

40

50

60

70

80 Q [m/h]

10

15

20

Q [l/s]

v [m/s]

0
TM02 5025 0504

10

-520/2

50

40
0

-330/2

60

-120/2

50

-250/2

65

-140/2

60

20

40

60

80 100 120 140

Q [m/h]

10

20

30

40

Q [l/s]

v [m/s]

Note: All QH-curves apply to single-head pumps. For further information, see page 44.

64

-700/2
-570/2
-400/2

75

70

Q [m/h]

TM02 8750 0904

Eta
[%]
80

-250/2

Technical data

B4

B4
AC

B4
P
AC

P
B3

H3

AD

H3

D1
B2

B1
L1

B2

L1

H4

D1
B1

H4

H1

H1

H2

H2

Rp 1/4

TM02 8632 5004 - TM02 8631 5004

B4
AD
AD

DN 80
2-pole, PN 6/10/16

M
AE

AF

AE

AF

AE

C1

AF

C1

C5

C6

C5

Technical data
TP 80

-120/2

-140/2

-180/2

-210/2

-240/2

-250/2

-330/2

-400/2

-520/2

-570/2

-700/2

TPD

TPE

TPED

Series

200

300

300

300

300

300

300

300

300

300

300

IEC size

1-phase TP

90

3-phase TP

90

90

100

112

132

132

160

160

160

180

200
-

1-phase TPE

3-phase TPE

90

90

100

112

132

132

160

160

160

180

1.1/1.5

-/2.2

-/3

-/4

-/5.5

-/7.5

-/11

-/15

-/18.5

-/22

-/30

1-/3-phase TP [kW]

P2

1-/3-phase TPE [kW]

PN

-/1.5

-/2.2

-/3

-/4

-/5.5

-/7.5

-/11

-/15

-/18.5

-/22

-/-

PN 6/PN10

PN 16

PN 16

PN 16

PN 16

PN 16

PN 16

PN 16

PN 16

PN 16

PN 16

Tmin ; Tmax

[C]

[-25;140]

D1

[mm]

80

80

80

80

80

80

80

80

80

80

80

[mm]

178/178

-/178

-/198

-/220

-/220

-/220

-/335

-/335

-/335

-/366

-/405

1-/3-phase TP

AC

1-/3-phase TPE [mm]


1-/3-phase TP

AD

[mm]

[-25;140] [-25;140] [-25;140] [-25;140] [-25;140] [-25;140] [-25;140] [-25;140] [-25;140] [-25;140]

-/178

-/178

-/198

-/220

-/220

-/220

-/258

-/313

-/313

-/350

-/-

139/110

-/110

-/120

-/134

-/134

-/134

-/241

-/241

-/241

-/285

-/327

1-/3-phase TPE [mm]

-/110

-/167

-/177

-/188

-/188

-/188

-/389

-/417

-/417

-/439

-/-

AE

1-/3-phase TPE [mm]

105/-

132

132

145

145

145

148

148

148

164

AF

1-/3-phase TPE [mm]

105/-

132

132

145

145

145

148

148

148

164

200

250

250

300

300

350

350

350

350

400

[mm]

B1

[mm]

125/225

125/296 125/296 125/296 125/296 144/366 144/366 144/366 162/416 162/416 162/416

B2

[mm]

100/235

133/290 133/290 133/290 133/290 176/354 176/354 176/354 187/405 187/405 187/405

B3

[mm]

240

[mm]

139/225

TP
B4

340

340

340

340

400

400

400

470

470

470

133/296 133/296 134/296 150/320 176/366 241/375 241/375 241/416 285/418 327/438

1-phase TPE

[mm]

3-phase TPE

[mm]

167/252

167/302 177/302 188/390 188/390 188/366 389/375 417/375 417/416 439/416

C1

[mm]

160/240

144/420 144/420 144/420 144/420 144/480 144/480 144/480 144/550 144/550 144/550

C5

[mm]

180/53

180/78

180/78

180/78

180/78

220/93

220/93

220/93

250/133 250/133 250/133

C6

[mm]

173

175

175

175

175

175

175

175

350

350

350

L1

[mm]

360

360

360

360

360

440

440

440

500

500

500

H1

[mm]

97

105

105

105

105

115

115

115

115

115

115

H2

[mm]

163

176

204

204

243

243

273

273

273

273

273

[mm]

541/541

-/602

-/644

-/681

-/739

-/749

-/891

-/891

-/935

-/990

-/1057

-/541

-/602

-/644

-/681

-/736

-/746

-/837

-/849

-/887

-/913

-/-

35

35

35

35

35

M16

M16

M16

M16

M16

M16

M16

M16

M16

M16

M16

H3
H4
M

1-/3-phase TP

1-/3-phase TPE [mm]


[mm]

2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with

motors as standard.

The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

65

Performance curves

DN 100
2-pole, PN 6/10/16

TP, TPD, TPE, TPED 100-XX/2


H
[m]
26

H
[m]

TP, TPE 100

-240/2

22

-200/2

50
45

-160/2

14

35
-120/2

-310/2

30

10

-250/2

25

20

6
4

15

10
0 10 20 30 40 50 60 70 80 90 100110 Q [m/h]

P2
[kW]
8

P2
[kW]
32

-240/2

0 20 40 60 80 100 120 140 160 180200 Q [m/h]

-480/2

28

24

-200/2

5
4

-390/2

20

-160/2

3
2

-360/2

16

-310/2

12

-250/2

-120/2

NPSH
[m]

0 10 20 30 40 50 60 70 80 90 100110 Q [m/h]

12

NPSH
[m]

0 20 40 60 80 100 120 140 160 180200 Q [m/h]


-480/2

14

-120/2

360/2,-390/2

12

10

10

-200/2, -240/2

-160/2

-250/2, -310/2

0
0 10 20 30 40 50 60 70 80 90 100110 Q [m/h]

Eta
[%]
85
80
75
70
65
60
55
50
45
40

75
70

-200/2

65

-240/2

-160/2

60
55
50

-120/2

45
40

0
0.0

5
0.5

10
1.0

15
1.5

20
2.0

2.5

25
3.0

30

Q [l/s]

3.5

v [m/s]

-480/2

-390/2
-310/2
-250/2

10

20
2

30
3

40
4

Note: All QH-curves apply to single-head pumps. For further information, see page 44.

66

-360/2

0 20 40 60 80 100 120 140 160 180200 Q [m/h]


TM02 5026 0504

0 10 20 30 40 50 60 70 80 90 100110 Q [m/h]

0 20 40 60 80 100 120 140 160 180200 Q [m/h]

50
5

60 Q [l/s]
7 v [m/s]

TM02 8751 0904

Eta
[%]
80

-390/2
-360/2

40

16
12

50 Hz

-480/2

55

20
18

TP, TPE 100

60

50 Hz

24

Technical data

B4

B4
AC

B4
P
AC

P
B3

H3

AD

H3

D1
B2

B1
L1

B2

L1

H4

D1
B1

H4

H1

H1

H2

H2

Rp 1/4

M
AE

AE

AF

AF

AE

C1

AF

C1

C5

C6

C5

TM02 8632 5004 - TM02 8631 5004

B4
AD
AD

DN 100
2-pole, PN 6/10/16

Technical data
Technical data

TP 100

-120/2

-160/2

-200/2

-240/2

-250/2

-310/2

-360/2

-390/2

-480/2

TPD

TPE

TPED

300

Series

IEC size

200

300

300

300

300

300

300

300

1-phase TP

3-phase TP

90

112

132

132

160

160

160

180

200
-

1-phase TPE

3-phase TPE

90

112

132

132

160

160

160

180

-/2.2

-/4

-/5.5

-/7.5

-/11

-/15

-/18.5

-/22

-/30

1-/3-phase TP [kW]

P2

1-/3-phase TPE [kW]

PN

-/2.2

-/4

-/5.5

-/7.5

-/11

-/15

-/18.5

-/22

-/-

PN 6/PN 10

PN 16

PN 16

PN 16

PN 16

PN 16

PN 16

PN 16

PN 16

Tmin ; Tmax

[C]

[-25;140]

D1

[mm]

100

100

100

100

100

100

100

100

100

[mm]

-/178

-/220

-/220

-/220

-/335

-/335

-/335

-/366

-/405

1-/3-phase TPE [mm]

-/178

-/220

-/220

-/220

-/258

-/313

-/313

-/350

-/-

1-/3-phase TP

[mm]

-/110

-/134

-/134

-/134

-/241

-/241

-/241

-/285

-/327

1-/3-phase TP

AC
AD

[-25;140] [-25;140] [-25;140] [-25;140] [-25;140] [-25;140] [-25;140] [-25;140]

1-/3-phase TPE [mm]

-/110

-/188

-/188

-/188

-/389

-/417

-/417

-/439

-/-

AE

1-/3-phase TPE [mm]

132

145

145

145

148

148

148

164

AF

1-/3-phase TPE [mm]

132

145

145

145

148

148

148

164

250

300

300

350

350

350

350

400

[mm]

B1

[mm]

125/245

124/347 124/347 124/347 151/414 151/414 151/414 151/414 173/443

B2

[mm]

100/265

156/332 156/332 156/332 190/395 190/395 190/395 190/395 201/429

B3

[mm]

280

[mm]

125/265

TP
B4

470

470

470

500

500

500

500

500

156/360 156/385 156/385 241/425 241/425 241/425 285/433 327/453

1-phase TPE

[mm]

3-phase TPE

[mm]

167/272

188/347 188/350 188/350 389/414 417/414 417/414 439/414

C1

[mm]

160/280

144/480 144/480 144/480 230/550 230/550 230/550 230/550 230/550

[mm]

225/83

250/104 250/104 250/104

C5

275/110

275/110

275/110

275/110

275/110
230

C6

[mm]

221

175

175

175

230

230

230

230

L1

[mm]

450

500

500

500

550

550

550

550

550

H1

[mm]

107

140

140

140

140

140

140

140

140

H2
H3
H4
M

[mm]

185

206

245

245

270

270

270

270

307

[mm]

-/613

-/718

-/776

-/776

-/913

-/913

-/957

-/1012

-/1116

1-/3-phase TPE [mm]

-/613

-/718

-/773

-/773

-/859

-/871

-/909

-/935

-/-

35

35

35

35

35

M16

M16

M16

M16

M16

M16

M16

M16

M16

1-/3-phase TP

[mm]

2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with

motors as standard.

The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

67

Performance curves

DN 32
4-pole, PN 6/10/16

TP, TPD, TPE, TPED, 4-pole, PN 6/10/16


TP, TPD, TPE, TPED 32-XXX/4
H
[m]
6.0

TP, TPE 32

-60/4

5.5

H
[m]
13

50 Hz

TP, TPE 32

-120/4

50 Hz

12

5.0

11

4.5

10

-40/4

4.0

-100/4

3.5
3.0

2.5

-30/4

-80/4

2.0

1.5

1.0

0.5
0.0

3
0

P2
[kW]
0.09
0.08
0.07
0.06
0.05
0.04
0.03
0.02
0.01
0.00

9Q [m/h]

P2
[kW]

-60/4

9 10 11 Q [m/h]

0.6

-120/4

0.5
0.4

-40/4
-30/4

-100/4

0.3

-80/4

0.2
0.1
0.0
0

NPSH
[m]
3.5

9Q [m/h]

9 10 11 Q [m/h]

9 10 11 Q [m/h]

NPSH
[m]

-40/4, -60/4

3.0
4

2.5

-30/4

2.0

1.5

1.0
1

0.5
0.0

0
0

9Q [m/h]

Eta
[%]
70

Eta
[%]
55

60

50

50

45

40

40

30

-40/4

-120/4
-80/4

35

-30/4

-60/4

20

-100/4

30

10

25
1

9Q [m/h]

0.0

0.5

1.0

1.5

2.0

2.5 Q [l/s]

0.0

0.5

1.0

1.5

2.0

2.5 v [m/s]

9 10 11 Q [m/h]

0.0

0.5

1.0

1.5

2.0

2.5

3.0

Q [l/s]

0.0

0.5

1.0

1.5

2.0

2.5

3.0

v [m/s]

Note: All QH-curves apply to single-head pumps. For further information, see page 44.

68

TM02 5028 0504

20
0

TM02 5027 0504

Technical data

B4

B4
AC

B4
P
AC

P
B3

H3

AD

H3

B1
L1

B2

D1
B2

L1

H4

D1
B1

H4

H1

H1

H2

H2

Rp 1/4

M
AE

AF

AE

AF

AE

C1

AF

C1

C5

C6

C5

TM02 8632 5004 - TM02 8631 5004

B4
AD
AD

DN 32
4-pole, PN 6/10/16

Technical data
TP 32

-30/4

-40/4

-60/4

-80/4

-100/4

-120/4

TPD

TPE

TPED

Series

200

200

200

300

300

300

1-phase TP

63

71

71

3-phase TP

63

71

70

71

71

80

1-phase TPE

71

71

71

71

71

80

3-phase TPE

-/0.25

-/0.37

-/0.55

IEC size

1-/3-phase TP [kW] 0.12/0.12 0.18/0.25 0.18/0.25

P2

1-/3-phase TPE [kW]

PN

0.37/-

0.37/-

0.37/-

0.25/-

0.37/-

0.55/-

PN 6/10

PN 6/10

PN 6/10

PN 16

PN 16

PN 16

Tmin ; Tmax

[C]

D1

[mm]

32

32

32

32

32

32

[mm]

118/118

142/141

142/141

-/141

-/141

-/141

1-/3-phase TP

AC

1-/3-phase TPE [mm]


1-/3-phase TP

AD

[-25;140] [-25;140] [-25;140] [-25;140] [-25;140] [-25;140]

141/-

[mm] 101/101

141/-

141/-

141/-

141/-

141/-

133/109

133/109

-/109

-/109

-/109

1-/3-phase TPE [mm]

140/-

140/-

140/-

140/-

140/-

140/-

AE

1-/3-phase TPE [mm]

105/-

105/-

105/-

105/-

105/-

105/-

AF

1-/3-phase TPE [mm]

105/-

105/-

105/-

105/-

105/-

105/-

170

170

200

[mm]

B1

[mm]

75/180

102/222

102/222

125/260 125/260 144/321

B2

[mm]

75/180

102/222

102/222

117/257

117/257

144/321

B3

[mm]

200

240

240

276

276

355

TP

[mm] 101/180

133/222

133/222

125/260 125/260 144/321

1-phase TPE

[mm] 140/275

140/225

140/225

140/260 140/260 144/321

3-phase TPE

[mm]

[mm]

80/200

80/240

80/240

144/356 144/356 144/435

C5

[mm]

110/52

140/82

140/82

170/45

B4
C1

170/45

220/46

C6

[mm]

103

103

103

175

175

175

L1

[mm]

220

280

280

340

340

440

H1

[mm]

68

79

79

100

100

100

H2

[mm]

142

125

125

129

129

156

395/395

395/395

-/420

-/420

-/487

408/-

395/-

395/-

440/-

440/-

507/-

M12

M12

M12

M16

M16

M16

2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with

H3
H4

1-/3-phase TP

[mm] 416/390

1-/3-phase TPE [mm]


[mm]

motors as standard.

The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

69

Performance curves

DN 40
4-pole, PN 6/10/16

TP, TPD, TPE, TPED 40-XXX/4


H
[m]
7

TP, TPE 40

H
[m]
16

50 Hz

15

-90/4

-160/4

TP, TPE 40
50 Hz

14

13

-60/4

-130/4

12
11

10

-100/4

-30/4

7
6

4
0

P2
[kW]

10

12

14 Q [m/h]

0.24

P2
[kW]

10 12 14 16 18

1.2

-60/4

0.20

-160/4

1.0

0.16

0.8

-90/4

0.12

0.6

0.08

0.4

-30/4

0.04

0.2

0.00

0.0
0

NPSH
[m]
3.5

10

12

14 Q [m/h]

-130/4
-100/4

10 12 14 16 18

Q [m/h]

10 12 14 16 18

Q [m/h]

NPSH
[m]
3.0

-90/4

3.0

2.5

2.5

2.0

-60/4

2.0

1.5

1.5

1.0

1.0
-30/4

0.5

0.5

0.0

0.0
0

10

12

14 Q [m/h]

Eta
[%]
65

Eta
[%]
60

60

-100/4

55

55

50

-60/4

50

-160/4

45

45

-90/4

40

-130/4

40

35

35

-30/4

30
2

0
0.0

1
0.5

10

2
1.0

1.5

12
3

2.0

14 Q [m/h]
4

2.5

Q [l/s]

3.0 v [m/s]

0
TM02 5029 0504

0
0

10 12 14 16 18

2
1

3
2

Note: All QH-curves apply to single-head pumps. For further information, see page 44.

4
3

Q [m/h]
Q [l/s]
4 v [m/s]

TM02 5030 0504

30

70

Q [m/h]

Technical data

B4

B4
AC

B4
P
AC

P
B3

H3

AD

H3

B1
L1

B2

D1
B2

L1

H4

D1
B1

H4

H1

H1

H2

H2

Rp 1/4

M
AE

AF

AE

AF

AE

C1

AF

C1

C5

C6

C5

TM02 8632 5004 - TM02 8631 5004

B4
AD
AD

DN 40
4-pole, PN 6/10/16

Technical data
TP 40

-30/4

-60/4

-90/4

-100/4

-130/4

TPD

-160/4
z

TPE

TPED

Series

200

200

200

300

300

300

1-phase TP

63

71

71

3-phase TP

63

71

71

80

80

90

1-phase TPE

71

71

71

80

80

3-phase TPE

90

90
-/1.1

IEC size

P2

1-/3-phase TP [kW] 0.12/0.12 0.25/0.25 0.18/0.25


1-/3-phase TPE [kW]

PN

-/0.55

-/0.75

0.37/-

0.37/-

0.37/-

0.55/-

0.75/0.75

-/1.1

PN 6/10

PN 6/10

PN 16

PN 16

PN 16

PN 16

Tmin ; Tmax

[C]

D1

[mm]

40

40

40

40

40

40

[mm]

118/118

141/141

141/141

-/141

-/141

-/178
-/178

1-/3-phase TP

AC

1-/3-phase TPE [mm]


1-/3-phase TP

AD

[-25;140] [-25;140] [-25;140] [-25;140] [-25;140] [-25;140]

141/-

[mm] 101/101

141/-

141/-

141/-

141/178

133/109

133/109

-/109

-/109

-/110

1-/3-phase TPE [mm]

140/-

140/-

140/-

140/-

140/167

-/167

AE

1-/3-phase TPE [mm]

105/-

105/-

105/-

105

105

132

AF

1-/3-phase TPE [mm]

105/-

105/-

105/-

105

105

132

[mm]

200

200

200

B1

[mm]

85/180

100/-

102/222

130/273

149/325

149/325

B2

[mm]

75/180

100/-

102/222

117/267

144/321

144/321

B3

[mm]

200

240

290

355

355
149/325

B4

TP

[mm] 101/180

133/-

133/222

130/273

149/325

1-phase TPE

[mm] 140/275

140/225

140/225

140/273

149/325

3-phase TPE

[mm]

167/325

167/325

C1

[mm] 120/200

120/-

120/240

144/400

144/435

144/435

C5

[mm]

125/-

160/95

170/45

220/108

220/108

125/45

C6

[mm]

125

125

175

175

175

L1

[mm]

250

250

320

340

440

440

H1

[mm]

67

75

68

100

110

110

H2

[mm]

146

123

128

166

158

158

389/389

388/388

-/497

-/499

-/549

411/-

389/-

388/-

517/-

519/549

-/549

M12

M12

M12

M16

M16

M16

2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with

H3
H4

1-/3-phase TP

[mm] 419/393

1-/3-phase TPE [mm]


[mm]

motors as standard.

The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

71

Performance curves

DN 50
4-pole, PN 6/10/16

TP, TPD, TPE, TPED 50-XXX/4


H
[m]

H
[m]

TP, TPE 50

-110/4

10

24

50 Hz

50 Hz

22

-90/4

20

-190/4

18

-60/4

16

-160/4

14

4
3

-130/4

12

-30/4

10

6
0

P2
[kW]

8 10 12 14 16 18 20 22 Q [m/h]

P2
[kW]
3.2

-110/4

0.7

12

16 20 24 28

-90/4

0.5

Q [m/h]

-230/4

2.4

-190/4

2.0

0.4

1.6

-60/4

0.3

-160/4

1.2

0.2

-130/4

0.8

0.1

-30/4

0.4

0.0

0.0
0

8 10 12 14 16 18 20 22 Q [m/h]

NPSH
[m]
3.5

12

16 20 24 28

32

Q [m/h]

12

16 20 24 28

32

Q [m/h]

NPSH
[m]
3.5

3.0

3.0

-60/4

2.5

2.5

2.0

2.0

1.5

1.5

-30/4

1.0

1.0

-90/4, -110/4

0.5

0.5

0.0

0.0
0

8 10 12 14 16 18 20 22 Q [m/h]

Eta
[%]
65

65

60

60

55
-90/4

50

-60/4

-110/4

45

35

30

30

0.0

8 10 12 14 16 18 20 22 Q [m/h]

0.5

1.0

4
1.5

5
2.0

6
2.5

Q [l/s]
3.0v [m/s]

0
TM02 5031 0504

-230/4

40

35
0

-190/4
-160/4

45

-30/4

40

-130/4

50

0
0

8
2
1

12

16 20 24 28
4

6
2

Note: All QH-curves apply to single-head pumps. For further information, see page 44.

32

8
3

Q [m/h]
10 Q [l/s]

v [m/s]

TM02 5032 0504

55

72

32

2.8

0.6

Eta
[%]
70

TP, TPE 50

-230/4

Technical data

B4

B4
AC

B4
P
AC

P
B3

H3

AD

H3

D1
B2

B1
L1

B2

L1

H4

D1
B1

H4

H1

H1

H2

H2

Rp 1/4

M
AE

AF

AE

AF

AE

C1

AF

C1

C5

C6

C5

TM02 8632 5004 - TM02 8631 5004

B4
AD
AD

DN 50
4-pole, PN 6/10/16

Technical data
TP 50

-30/4

-60/4

-90/4

-110/4

-130/4

-160/4

-190/4

-230/4

TPD

TPE

TPED

Series

200

200

300

300

300

300

300

300

1-phase TP

71

71

3-phase TP

71

71

80

80

90

90

100

100

1-phase TPE

71

71

80

80

3-phase TPE

90

90

90

90
-/3

IEC size

P2

1-/3-phase TP [kW] 0.18/0.25 0.37/0.37


1-/3-phase TPE [kW]

PN
Tmin ; Tmax

[C]

D1

[mm]
1-/3-phase TP

AC
AD

-/0.75

-/1.1

-/1.5

-/2.2

0.37/-

0.55/-

0.75/0.75

-/1.1

-/1.5

-/2.2

-/3

PN 6/10

PN 6/10

PN 16

PN 16

PN 16

PN 16

PN 16

PN 16

[-25;140] [-25;140] [-25;140] [-25;140] [-25;140] [-25;140] [-25;140] [-25;140]


50

[mm] 141/141

1-/3-phase TPE [mm]


1-/3-phase TP

-/0.55

0.37/-

141/-

[mm] 133/109

50

50

50

50

50

50

50

141/141

-/141

-/141

-/178

-/178

-/198

-/198

141/-

141/-

141/178

-/178

-/178

-/198

-/220

133/109

-/109

-/109

-/110

-/110

-/120

-/120

1-/3-phase TPE [mm]

140/-

140/-

140/-

140/167

-/167

-/167

-/177

-/188

AE

1-/3-phase TPE [mm]

105/-

105/-

105

105/132

132

132

132

145

AF

1-/3-phase TPE [mm]

105/-

105/-

105

105/132

132

132

132

145

200

200

200

200

250

250

[mm]

B1

[mm]

90/181

110/225

133/290

180/386

180/386 180/386 180/386 180/386

B2

[mm]

75/186

100/225

119/284

164/379

164/379 164/379 164/379 164/379

[mm]

200

B3

240

320

420

[mm] 133/181

133/225

133/290

180/386

1-phase TPE

[mm] 140/275

140/225

140/290

180/386

3-phase TPE

[mm]

180/386

TP
B4

420

420

420

420

180/386 180/386 180/386 180/386


-

180/386 180/386 180/386 188/386

C1

[mm] 120/200

120/240

144/400

144/500

144/500 144/500 144/500 144/500

C5

[mm]

140/60

170/52

220/123

220/123 220/123 220/123 220/123

140/60

C6

[mm]

125

125

175

175

175

175

175

175

L1

[mm]

280

280

340

440

440

440

440

440

H1

[mm]

82

82

115

115

115

115

115

115

H2

[mm]

135

127

161

167

167

167

195

195

452/400

-/507

-/513

-/563

-/603

-/645

-/645

408/-

400/-

527/-

533/563

-/603

-/603

-/645

-/682

M12

M12

M16

M16

M16

M16

M16

M16

2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with

H3
H4

1-/3-phase TP

[mm] 408/408

1-/3-phase TPE [mm]


[mm]

motors as standard.

The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

73

Performance curves

DN 65
4-pole, PN 6/10/16

TP, TPD, TPE, TPED 65-XXX/4


H
[m]

H
[m]
11

-110/4

TP, TPE 65
50 Hz

10

TP, TPE 65
50 Hz

22

-90/4

-240/4

24

20

18

7
6

-170/4

16

-60/4

-150/4

14
-130/4

12

-30/4

10

1
0

6
0

P2
[kW]

12 16 20 24 28 32 36

1.2

Q [m/h]

P2
[kW]
4.0

-110/4

5 10 15 20 25 30 35 40 45 50 Q [m/h]
-240/4

3.5

1.0

3.0

0.8

2.5

-90/4

-170/4
-150/4

2.0

0.6

-60/4

1.5

0.4

-130/4

1.0

0.2

0.5

-30/4

0.0

0.0
0

12 16 20 24 28 32 36

Q [m/h]

NPSH
[m]

5 10 15 20 25 30 35 40 45 50 Q [m/h]

5 10 15 20 25 30 35 40 45 50 Q [m/h]

NPSH
[m]

2.5

2.5

-60/4

-30/4

2.0

2.0

1.5

1.5

1.0

1.0
-90/4, -110/4

0.5

0.5

0.0
4

12 16 20 24 28 32 36

Q [m/h]

Eta
[%]
70

-90/4

70
65

-110/4

60

-240/4

65
60

-60/4

-130/4
-150/4

55

55

50

50

45

-30/4

45

40

40
35

35
4

12 16 20 24 28 32 36

0.0

0.5

1.0

6
1.5

8
2.0

10
2.5

Q [m/h]
Q [l/s]
3.0v [m/s]

0
TM02 5033 0504

0
0

5 10 15 20 25 30 35 40 45 50 Q [m/h]
2

4
1

8
2

Note: All QH-curves apply to single-head pumps. For further information, see page 44.

74

-170/4

10

12
3

14

Q [l/s]
4 v [m/s]

TM02 5043 0504

Eta
[%]
75

0.0
0

Technical data

B4

B4
AC

B4
P
AC

P
B3

H3

AD

H3

D1
B2

B1
L1

B2

L1

H4

D1
B1

H4

H1

H1

H2

H2

Rp 1/4

M
AE

AF

AE

AF

AE

C1

AF

C1

C5

C6

C5

TM02 8632 5004 - TM02 8631 5004

B4
AD
AD

DN 65
4-pole, PN 6/10/16

Technical data
TP 65

-30/4

-60/4

-90/4

-110/4

-130/4

-150/4

-170/4

-240/4

TPD

TPE

TPED

Series

200

200

300

300

300

300

300

300

1-phase TP

71

80

3-phase TP

71

80

80

90

90

100

100

112

1-phase TPE

71

80

80

3-phase TPE

100

90

90

100

100

112
-/4

IEC size

1-/3-phase TP [kW] 0.25/0.25 0.55/0.55

P2

1-/3-phase TPE [kW]

PN
Tmin ; Tmax

[C]

D1

[mm]
1-/3-phase TP

AC
AD

-/1.1

-/1.5

-/2.2

-/3

0.55/-

0.75/0.75

-/1.1

-/1.5

-/2.2

-/3

-/4

PN 6/10

PN 6/10

PN 16

PN 16

PN 16

PN 16

PN 16

PN 16

[-25;140] [-25;140] [-25;140] [-25;140] [-25;140] [-25;140] [-25;140] [-25;140]


65

[mm] 141/141

1-/3-phase TPE [mm]


1-/3-phase TP

-/0.75

0.37/-

141/-

[mm] 133/109

65

65

65

65

65

65

65

141/141

-/141

-/178

-/178

-/198

-/198

-/220
-/220

141/-

141/178

-/178

-/178

-/198

-/220

133/109

-/109

-/110

-/110

-/120

-/120

-/134

1-/3-phase TPE [mm]

140/-

140/-

140/167

-/167

-/167

-/177

-/188

-/188

AE

1-/3-phase TPE [mm]

105/-

105/-

105/132

132

132

132

145

145

AF

1-/3-phase TPE [mm]

105/-

105/-

105/132

132

132

132

145

145

200

200

200

250

250

250

[mm]

B1

[mm] 125/230

125/230

142/298

178/349 178/349 178/349 178/349 178/349

B2

[mm] 100/240

100/240

124/290

164/383 164/383 164/383 164/383 164/383

B3

[mm]

240

320
142/298

B4

240

440

440

440

440

440

TP

[mm] 133/240

133/240

1-phase TPE

[mm] 140/240

140/240

142/298

3-phase TPE

[mm]

167/355

178/383 178/383 178/383 188/383 188/383

178/383 178/383 178/383 178/383 178/383


-

C1

[mm] 160/240

160/240

144/400

144/520 144/520 144/520 144/520 144/520

C5

[mm]

170/63

180/65

238/111

170/63

238/111

238/111

238/111

238/111
175

C6

[mm]

153

153

175

175

175

175

175

L1

[mm]

340

340

360

475

475

475

475

475

H1

[mm]

97

97

105

125

125

125

125

125

[mm]

135

H2

147

172

166

166

194

194

194

475/475

-/508

-/572

-/612

-/654

-/654

-/691

423/-

475/-

528/558

-/612

-/612

-/654

-/691

-/707

M16

M16

M16

M16

M16

M16

M16

M16

2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with

H3
H4

1-/3-phase TP

[mm] 423/423

1-/3-phase TPE [mm]


[mm]

motors as standard.

The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

75

Performance curves

DN 80
4-pole, PN 6/10/16

TP, TPD, TPE, TPED 80-XXX/4


H
[m]
11

-110/4

TP, TPE 80

H
[m]
34

50 Hz

32

10
9

-90/4

30

-70/4

26

-60/4

24

7
6

-270/4
-240/4

22

20

18

-30/4

-170/4

16

-150/4

14

12

10
0

10

20

30

40

50

60

70 Q [m/h]

P2
[kW]
12

-110/4

2.0

0 10 20 30 40 50 60 70 80 90 100 Q [m/h]

-340/4

10

1.6

-90/4

1.2
0.8
0.4

-70/4

-60/4

-270/4
-240/4
-170/4
-150/4

-30/4

0.0

0
0

10

20

30

40

50

60

70 Q [m/h]

0 10 20 30 40 50 60 70 80 90 100 Q [m/h]

NPSH
[m]

NPSH
[m]

-30/4

-270/4, 340/4

-60/4 90/4, -110/4

-240/4

-150/4, 170/4

-70/4

0
Eta
[%]
80

0
0

10

20

30

40

50

60

70 Q [m/h]

Eta
[%]
75

-90/4

75

0 10 20 30 40 50 60 70 80 90 100 Q [m/h]
-170/4
-150/4

70

70

-110/4

-70/4

65

-340/4

65

-240/4 -270/4

60

60

55

55

-60/4

50

50

-30/4

45

45

40

40

0
0

10

20
4

30

40

8
1

12
2

50

60
16
3

70 Q [m/h]
20

Q [l/s]

4 v [m/s]

0 10 20 30 40 50 60 70 80 90 100 Q [m/h]
TM02 5044 0504

0
0

8
1

12
2

16
3

Note: All QH-curves apply to single-head pumps. For further information, see page 44.

76

20
4

24

28
5

Q [l/s]
6v [m/s]

TM02 8752 0904

P2
[kW]

50 Hz

28

TP, TPE 80

-340/4

Technical data

B4

B4

B4
AC

P
AC

P
B3

H3

AD

H3

B1
L1

B2

D1
B2

L1

H4

D1
B1

H4

H1

H1

H2

H2

Rp 1/4

M
AE

AF

AE

AF

AE

C1

AF

C1

C5

C6

C5

TM02 8632 5004 - TM02 8631 5004

B4
AD
AD

DN 80
4-pole, PN 6/10/16

Technical data
TP 80

-30/4

-60/4

-70/4

-90/4

-110/4

-150/4

-170/4

-240/4

-270/4

-340/4

TPD

TPE

TPED

Series

200

200

300

300

300

300

300

300

300

300

1-phase TP

80

80

3-phase TP

71

80

90

90

100

100

112

132

132

160

1-phase TPE

71

80

3-phase TPE

90

90

100

112

112

132

160

160

1-/3-phase TP [kW]

0.37/0.37

0.75/0.75

-/1.1

-/1.5

-/2.2

-/3

-/4

-/5.5

-/7.5

-/11

1-/3-phase TPE [kW]

0.37/-

0.75/0.75

-/1.1

-/1.5

-/2.2

-/3

-/4

-/5.5

-/7.5

-/11

PN 16

PN 16

PN 16

PN 16

PN 16

PN 16

PN 16

PN 16

IEC size

P2
PN

PN 6/PN 10 PN 6/PN 10

Tmin ; Tmax

[C]

[-25;140]

[-25;140]

D1

[mm]

80

80

80

80

80

80

80

80

80

80

[mm]

142/141

178/141

-/178

-/178

-/198

-/198

-/220

-/276

-/276

-/335

1-/3-phase TP

AC

1-/3-phase TPE [mm]


1-/3-phase TP

AD

[mm]

[-25;140] [-25;140] [-25;140] [-25;140] [-25;140] [-25;140] [-25;140] [-25;140]

141/-

141/178

-/178

-/178

-/198

-/220

-/220

-/220

-/258

-/258

133/109

139/109

-/110

-/110

-/120

-/120

-/134

-/198

-/198

-/241

1-/3-phase TPE [mm]

140/-

140/167

-/167

-/167

-/177

-/188

-/188

-/188

-/389

-/389

AE

1-/3-phase TPE [mm]

105/-

132

132

132

132

145

145

145

148

148

AF

1-/3-phase TPE [mm]

105/-

132

132

132

132

145

145

145

148

148

200

200

250

250

250

300

300

350

[mm]

B1

[mm]

130/230

135/240

144/366 144/366 144/366 162/416 162/416 162/491 162/491 162/491

B2

[mm]

100/240

100/250

176/354 176/354 176/354 187/405 187/405 187/480 187/480 187/480

B3

[mm]

240

240

[mm]

133/230

139/240

1-phase TPE

[mm]

140/240

140/250

3-phase TPE

[mm]

167/315

176/366 176/366 177/366 188/416 188/416 243/491 389/491 389/491

C1

[mm]

160/240

160/240

144/480 144/480 144/480 144/550 144/550 144/550 144/550 144/550

C5

[mm]

180/53

180/53

220/93

TP
B4

400

400

400

470

470

500

500

500

176/366 176/366 176/366 187/416 187/416 198/491 198/491 241/491


-

220/93

220/93

250/133 250/133 310/105 310/105 310/105

C6

[mm]

173

173

175

175

175

350

350

350

350

L1

[mm]

360

360

440

440

440

500

500

620

620

620

H1

[mm]

107

107

115

115

115

115

115

140

140

140

H2
H3
H4
M

1-/3-phase TP

350

[mm]

163

153

176

176

204

204

204

273

273

303

[mm]

513/461

551/491

-/572

-/612

-/654

-/654

-/691

-/833

-/871

-/946

461/-

491/541

-/612

-/612

-/654

-/691

-/707

-/801

-/892

-/892

35

M16

M16

M16

M16

M16

M16

M16

M16

M16

M16

1-/3-phase TPE [mm]


[mm]

2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with

motors as standard.

The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

77

Performance curves

DN 100
4-pole, PN 6/10/16

TP, TPD, TPE, TPED 100-XXX/4


H
[m]

TP, TPE 100

20
18

50 Hz

-170/4

16
-130/4

14
12

-110/4

10

-90/4

-70/4

-60/4

-30/4

2
0
0 10 20 30 40 50 60 70 80 90 100 Q [m/h]

P2
[kW]
6

-170/4

5
4

-130/4
-110/4

-90/4

-70/4
-60/4

1
-30/4

0
NPSH
[m]

0 10 20 30 40 50 60 70 80 90 100 Q [m/h]

10

-30/4

-130/4, -170/4

6
-60/4

-90/4, -110/4

2
-70/4

0
Eta
[%]
80

0 10 20 30 40 50 60 70 80 90 100 Q [m/h]
-170/4

75

-110/4
-90/4
-70/4 -130/4

70
65
-30/4

60

-60/4

55
50
45
40

0
0.0

5
0.5

10
1.0

15
1.5

20
2.0

2.5

25
3.0

30 Q [l/s]
v [m/s]

TM02 5045 0504

0 10 20 30 40 50 60 70 80 90 100 Q [m/h]

Note: All QH-curves apply to single-head pumps. For further information, see page 44.

78

Technical data

B4

B4
AC

B4
P
AC

P
B3

H3

AD

H3

D1
B2

B1
L1

B2

L1

H4

D1
B1

H4

H1

H1

H2

H2

Rp 1/4

M
AE

AF

AE

AF

AE

C1

AF

C1

C5

C6

C5

TM02 8632 5004 - TM02 8631 5004

B4
AD
AD

DN 100
4-pole, PN 6/10/16

Technical data
TP 100

-30/4

-60/4

-70/4

-90/4

-110/4

-130/4

-170/4

TPD

TPE

TPED

Series

200

200

300

300

300

300

300

1-phase TP

80

90

3-phase TP

80

90

90

100

100

112

132

1-phase TPE

80

3-phase TPE

90

90

100

112

132

132

1-/3-phase TP [kW]

0.55/0.55

1.1/1.1

-/1.5

-/2.2

-/3

-/4

-/5.5

1-/3-phase TPE [kW]

0.55/-

-/1.1

-/1.5

-/2.2

-/3

-/4

-/5.5

PN 16

PN 16

PN 16

PN 16

PN 16

IEC size

P2
PN

PN 6/PN 10 PN 6/PN 10

Tmin ; Tmax

[C]

D1

[mm]

100

100

100

100

100

100

100

[mm]

141/141

178/178

-/178

-/198

-/198

-/220

-/276

1-/3-phase TP

AC

1-/3-phase TPE [mm]

[-25;140]

[-25;140]

[-25;140] [-25;140] [-25;140] [-25;140] [-25;140]

141/-

-/178

-/178

-/198

-/220

-/220

-/220

133/109

139/110

-/110

-/120

-/120

-/134

-/198

1-/3-phase TPE [mm]

140/-

-/167

-/167

-/177

-/188

-/188

-/188

AE

1-/3-phase TPE [mm]

105/-

132

132

132

145

145

145

AF

1-/3-phase TPE [mm]

105/-

132

132

132

145

145

145

200

200

200

250

300

1-/3-phase TP

AD

[mm]

[mm]

B1

[mm]

175/280

175/280

151/414 151/414 151/414 173/443 173/443

B2

[mm]

125/305

125/305

190/395 190/395 190/395 201/429 201/429

B3

[mm]

280

280

[mm]

175/280

175/280

1-phase TPE

[mm]

140/305

3-phase TPE

[mm]

167/272

190/414 190/414 190/414 201/443 201/443

C1

[mm]

200/280

200/280

230/550 230/550 230/550 230/550 230/550

C5

[mm]

225/83

225/83

250/110

TP
B4

470

470

470

500

500

190/414 190/414 190/414 201/443 201/443


-

275/110

275/110

275/110

275/110
230

C6

[mm]

221

221

230

230

230

230

L1

[mm]

450

450

500

550

550

550

550

H1

[mm]

122

122

140

140

140

140

140

H2
H3
H4
M

1-/3-phase TP

[mm]

172

182

173

201

201

261

277

[mm]

525/525

625/585

-/634

-/676

-/676

-/773

-/837

525/-

-/585

-/634

-/676

-/713

-/789

-/805

M16

M16

M16

M16

M16

M16

M16

1-/3-phase TPE [mm]


[mm]

2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with

motors as standard.

The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

79

Performance curves

DN 100
4-pole, PN 6/10/16

TP, TPD, TPE, TPED 100-XXX/4


H
[m]

TP, TPE 100

40

50 Hz

-410/4

36

-370/4

32

-330/4

28
-250/4

24

-200/4

20
16
12
P2
[kW]

20 40 60 80 100 120 140 160 180

Q [m/h]

24

-410/4

20

-370/4

16

-330/4

12

-250/4

-200/4

4
0
0

20 40 60 80 100 120 140 160 180

Q [m/h]

NPSH
[m]
10

-330/4, -370/4, -410/4

8
6
4
-200/4, -250/4

2
0
Eta
[%]
80

20 40 60 80 100 120 140 160 180

Q [m/h]

-410/4

75
70

-200/4

65

-330/4
-250/4

-370/4

60
55
50
45
40
20 40 60 80 100 120 140 160 180

10

20
2

30
3

40
4

50
5

Q [m/h]
Q [l/s]
v [m/s]

TM02 8753 0904

Note: All QH-curves apply to single-head pumps. For further information, see page 44.

80

Technical data

B4

B4
AC

B4
P
AC

P
B3

H3

AD

H3

B1
L1

B2

D1
B2

L1

H4

D1
B1

H4

H1

H1

H2

H2

Rp 1/4

M
AE

AF

AE

AF

AE

C1

AF

C1

C5

C6

C5

TM02 8632 5004 - TM02 8631 5004

B4
AD
AD

DN 100
4-pole, PN 6/10/16

Technical data
TP 100

-200/4

-250/4

-330/4

-370/4

-410/4

TPD

TPE

TPED

Series

300

300

300

300

300

IEC size

P2

1-phase TP

3-phase TP

132

160

160

180

180

1-phase TPE

3-phase TPE

160

160

160

180

180

1-/3-phase TP [kW]

-/7.5

-/11

-/15

-/18.5

-/22

1-/3-phase TPE [kW]

-/7.5

-/11

-/15

-/18.5

-/22

PN 16

PN 16

PN 16

PN 16

PN 16

PN
Tmin ; Tmax

[C]

D1

[mm]

100

100

100

100

100

[mm]

-/276

-/335

-/335

-/366

-/366

1-/3-phase TPE [mm]

-/258

-/258

-/313

-/313

-/350

1-/3-phase TP

[mm]

-/198

-/241

-/241

-/285

-/285

1-/3-phase TPE [mm]

-/389

-/389

-/417

-/417

-/439

AE

1-/3-phase TPE [mm]

148

148

148

164

164

AF

1-/3-phase TPE [mm]

148

148

148

164

164

[mm]

300

350

350

350

350

B1

[mm] 249/579 249/579 249/579 249/579 249/579

1-/3-phase TP

AC
AD

[-25;140] [-25;140] [-25;140] [-25;140] [-25;140]

B2

[mm] 290/561 290/561 290/561 290/561 290/561

B3

[mm]
TP

B4

600

600

600

600

600

[mm] 290/579 290/579 290/579 290/579 290/579

1-phase TPE

[mm]

3-phase TPE

[mm] 389/579 389/579 417/579 417/579 439/579

C1

[mm] 230/680 230/680 230/680 230/680 230/680

C5

[mm] 335/110

335/110

335/110

335/110

335/110
350

C6

[mm]

350

350

350

350

L1

[mm]

670

670

670

670

670

H1

[mm]

175

175

175

175

175

H2

[mm]

254

308

308

308

308

[mm]

-/887

-/986

-/1030

-/1085

-/1085

1-/3-phase TPE [mm]

-/908

-/932

-/982

-/982

-/1008

35

35

35

35

M16

M16

M16

M16

M16

2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with

H3
H4

1-/3-phase TP

[mm]

motors as standard.

The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

81

Performance curves

DN 125
4-pole, PN 6/10/16

TP, TPD, TPE, TPED 125-XXX/4


H
[m]

H
[m]

15

TP, TPE 125

-160/4

14
13
-130/4

12
11

36

-360/4

32

-320/4

28

-110/4

10
9

24

20

TP, TPE 125

-420/4

40

50 Hz

50 Hz

-250/4
-210/4

7
16

6
5

12
0

P2
[kW]

20 40 60 80 100 120 140 160

Q [m/h]

P2
[kW]

-160/4

28

-130/4

20

40

80

120

160

5
4

Q [m/h]
-420/4

-360/4
-320/4

16

-110/4

-250/4
-210/4

12

2
1

4
0

20 40 60 80 100 120 140 160

Q [m/h]

NPSH
[m]

40

80

120

160

NPSH
[m]
6

200

Q [m/h]

-320/4, -360/4, -420/4

-210/4, -250/4

-110/4, -130/4, 160/4

0
0

20 40 60 80 100 120 140 160

Q [m/h]

Eta
[%]
75

-160/4

75

40

80

120

160

200

Q [m/h]

-360/4

70

70

-110/4

-130/4

-320/4
-210/4
-250/4

65

65

60

60

-420/4

55

55

50

45

45

40

40
20 40 60 80 100 120 140 160

0
0.0

10
0.5

20
1.0

1.5

30
2.0

40
2.5

3.0

Q [m/h]
50 Q [l/s]

3.5

v [m/s]

TM02 8755 0904

40

10

80

120

20
1

30
2

160
40
3

Note: All QH-curves apply to single-head pumps. For further information, see page 44.

200
50

60
4

Q [m/h]
Q [l/s]
5v [m/s]

TM02 8756 0904

50

82

200

24

Eta
[%]
80

Technical data

B4

B4
AC

B4
P
AC

P
B3

H3

AD

H3

B1
L1

B2

D1
B2

L1

H4

D1
B1

H4

H1

H1

H2

H2

Rp 1/4

M
AE

AF

AE

AF

AE

C1

AF

C1

C5

C6

C5

TM02 8632 5004 - TM02 8631 5004

B4
AD
AD

DN 125
4-pole, PN 6/10/16

Technical data
TP 125

-110/4

-130/4

-160/4

-210/4

-250/4

-320/4

-360/4

-420/4

TPD

TPE

TPED

Series

300

300

300

300

300

300

300

300

IEC size

P2

1-phase TP

3-phase TP

112

132

132

160

160

180

180

200

1-phase TPE

3-phase TPE

132

132

160

160

160

180

180

1-/3-phase TP [kW]

-/4

-/5.5

-/7.5

-/11

-/15

-/18.5

-/22

-/30

1-/3-phase TPE [kW]

-/4

-/5.5

-/7.5

-/11

-/15

-/18.5

-/22

-/-

PN 16

PN 16

PN 16

PN 16

PN 16

PN 16

PN 16

PN 16

PN
Tmin ; Tmax

[C]

D1

[mm]

125

125

125

125

125

125

125

125

[mm]

-/220

-/276

-/276

-/335

-/335

-/366

-/366

-/405

1-/3-phase TPE [mm]

-/220

-/220

-/258

-/258

-/313

-/313

-/350

-/-

1-/3-phase TP

[mm]

-/134

-/198

-/198

-/241

-/241

-/285

-/285

-/327

1-/3-phase TP

AC
AD

[-25;140] [-25;140] [-25;140] [-25;140] [-25;140] [-25;140] [-25;140] [-25;140]

1-/3-phase TPE [mm]

-/188

-/188

-/389

-/389

-/417

-/417

-/439

-/-

AE

1-/3-phase TPE [mm]

145

145

148

148

148

164

164

AF

1-/3-phase TPE [mm]

145

145

148

148

148

164

164

[mm]

250

300

300

350

350

350

350

400

B1

[mm] 202/537 202/537 202/537 243/566 243/566 243/566 243/566 243/566

B2

[mm] 250/518 250/518 250/518 271/552 271/552 271/552 271/552 271/552

B3

[mm]

B4
C1

600

600

600

600

600

600

600

600

TP

[mm] 250/537 250/537 250/537 271/566 271/566 285/566 285/566 327/566

1-phase TPE

[mm]

3-phase TPE

[mm] 250/537 250/537 389/537 389/566 417/566 417/566 439/566

[mm] 230/680 230/680 230/680 230/680 230/680 230/680 230/680 230/680

C5

[mm]

310/84

310/84

310/84

400/175 400/175 400/175 400/175 400/175

C6

[mm]

300

300

300

350

350

350

350

L1

[mm]

620

620

620

800

800

800

800

800

H1

[mm]

215

215

215

215

215

215

215

215

H2

350

[mm]

267

283

283

318

318

318

318

318

[mm]

-/854

-/917

-/955

-/1036

-/1080

-/1135

-/1135

-/1202

1-/3-phase TPE [mm]

-/870

-/886

-/989

-/982

-/1032

-/1032

-/1058

-/-

35

35

35

35

35

M16

M16

M16

M16

M16

M16

M16

M16

2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with

H3
H4

1-/3-phase TP

[mm]

motors as standard.

The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

83

Performance curves

DN 150
4-pole, PN 6/10/16

TP, TPD, TPE, TPED 150-XXX/4


H
[m]

TP, TPE 150

24

-250/4

22

-220/4

50 Hz

20

-200/4

18
16

-160/4

14
-130/4

12
10
8
6
P2
[kW]

40 80 120 160 200 240 280 320

Q [m/h]

24

-250/4

20

-220/4

16

-200/4

12

-160/4

-130/4

4
0
0

40 80 120 160 200 240 280 320

Q [m/h]

NPSH
[m]
6

-130/4, -160/4, -200/4, -220/4, -250/4

5
4
3
2
1
Eta
[%]
85

40 80 120 160 200 240 280 320

Q [m/h]

80

-250/4

75

-160/4 -200/4

70

-130/4

65

-220/4

60
55
50
45
40 80 120 160 200 240 280 320

20

40

60

80
4

Q [m/h]
100 Q [l/s]
5

v [m/s]

TM02 8754 0904

Note: All QH-curves apply to single-head pumps. For further information, see page 44.

84

Technical data

B4

B4
AC

B4
P
AC

P
B3

H3

AD

H3

B1
L1

B2

D1
B2

L1

H4

D1
B1

H4

H1

H1

H2

H2

Rp 1/4

M
AE

AF

AE

AF

AE

C1

AF

C1

C5

C6

C5

TM02 8632 5004 - TM02 8631 5004

B4
AD
AD

DN 150
4-pole, PN 6/10/16

Technical data
TP 150

-130/4

-160/4

-200/4

-220/4

-250/4

TPD

TPE

TPED

Series

300

300

300

300

300

IEC size

P2

1-phase TP

3-phase TP

132

160

160

180

180

1-phase TPE

3-phase TPE

160

160

160

180

180

1-/3-phase TP [kW]

-/7.5

-/11

-/15

-/18.5

-/22

1-/3-phase TPE [kW]

-/7.5

-/11

-/15

-/18.5

-/22

PN 16

PN 16

PN 16

PN 16

PN 16

PN
Tmin ; Tmax

[C]

D1

[mm]

150

150

150

150

150

[mm]

-/276

-/335

-/335

-/366

-/366

1-/3-phase TPE [mm]

-/258

-/258

-/313

-/313

-/350

1-/3-phase TP

[mm]

-/198

-/241

-/241

-/285

-/285

1-/3-phase TPE [mm]

-/389

-/389

-/417

-/417

-/439

AE

1-/3-phase TPE [mm]

148

148

148

164

164

AF

1-/3-phase TPE [mm]

148

148

148

164

164

[mm]

300

350

350

350

350

B1

[mm] 237/583 237/583 237/583 237/583 237/583

1-/3-phase TP

AC
AD

[-25;140] [-25;140] [-25;140] [-25;140] [-25;140]

B2

[mm] 296/553 296/553 296/553 296/553 296/553

B3

[mm]
TP

B4

600

600

600

600

600

[mm] 296/583 296/583 296/583 296/583 296/583

1-phase TPE

[mm]

3-phase TPE

[mm] 389/583 389/583 417/583 417/583 439/583

C1

[mm] 230/680 230/680 230/680 230/680 230/680

[mm] 400/153 400/153 400/153 400/153 400/153

C5
C6

[mm]

350

350

350

350

L1

[mm]

800

800

800

800

800

H1

[mm]

215

215

215

215

215

H2

350

[mm]

291

321

321

321

321

[mm]

-/964

-/1040

-/1084

-/1139

-/1139

1-/3-phase TPE [mm]

-/986

-/986

-/1036

-/1036

-/1062

35

35

35

35

M16

M16

M16

M16

M16

2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with

H3
H4

1-/3-phase TP

[mm]

motors as standard.

The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

85

Performance curves

DN 150
4-pole, PN 6/10/16

TP 150-XXX/4
H
[m]
38

TP 150

-370/4

36

50 Hz

34
32

-310/4

30
28
26
24
22
20
18
16
14
P2
[kW]

50 100 150 200 250 300 350 400Q [m/h]

40
35
-370/4

30
-310/4

25
20
15
NPSH
[m]

50 100 150 200 250 300 350 400Q [m/h]

50 100 150 200 250 300 350

6
5
4
3
2
1
0

-370/4
-310/4

86

Q [m/h]

50 100 150 200 250 300 350

20

40

60

80
4

100
5

Q [m/h]
Q [l/s]
6 v [m/s]

TM02 6818 0504

Eta
[%]
85
80
75
70
65
60
55
50
45
40

Technical data

DN 150
4-pole, PN 6/10/16

H3

AC

H1

H2

D1S

D1D

B4

TM02 8349 5004

B7

B2
B1

C2
Rp 3/8

B9

C7

AD
B8

C8

C8

L2

L3
L1

Rp 3/8

Technical data
TP 150

-310/4

-370/4

TPD

TPE

TPED

400

400

Series

IEC size

1-phase TP

3-phase TP

200

225

1-phase TPE

3-phase TPE

30

37

10

10

P2

[kW]

PN
Tmin ; Tmax

[C]

D1D/D1S

[mm] 150/200 150/200

AC

[mm]

405

463

AD

[mm]

327

366

[mm]

450

550

B1

[mm]

170

170

B2

[mm]

499

499

B4

[mm]

170

170

B7

[mm]

534

534

B8

[mm]

229

229

B9

[mm]

270

270

C2

[mm]

510

510

C7

[mm]

400

400

C8

[mm]

50

50

[mm]

20

20

L1

[mm]

740

740

L2

[mm]

140

140

L3

[mm]

500

500

H1

[mm]

220

220

H2

[mm]

293

323

H3

[mm]

1182

1291

[-25;120] [-25;120]

2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with

motors as standard.

87

Performance curves

DN 200
4-pole, PN 6/10/16

TP 200-XXX/4
H
[m]
44

TP 200

-430/4

40

50 Hz

-39
0/4

36
32

-30
0/4
-260
/4

28
24
20
16
12
8
4
P2
[kW]

100

200

300

400

500

600 Q [m/h]
-430/4

50

-390/4

40
30

-300/4
-260/4

20
10
0
NPSH
[m]

100

200

300

400

500

600 Q [m/h]

100

200

300

400

500

600 Q [m/h]

6
5
4
3
2
1
Eta
[%]
80
70
60

-390/4

-430/4

50
-300/4

40

-260/4

100

0
0

88

200
50

300

400

500

100
2

600 Q [m/h]

150

Q [l/s]

6v [m/s]

TM02 6817 0504

30

Technical data

DN 200
4-pole, PN 6/10/16

H3

AC

H1

H2

D1S

D1D

B4

Rp 3/8

TM02 8349 5004

B2
B1

AD
B8

C2

B7

C7
B9

C8

C8

L2

L3
L1

Rp 3/8

Technical data
TP 200

-260/4

-300/4

-390/4

-430/4

TPD

TPE

TPED

400

Series

IEC size

400

400

400

1-phase TP

3-phase TP

200 L

225 S

225 M

250 M

1-phase TPE

3-phase TPE

30

37

45

55

10

10

10

10

P2

[kW]

PN
Tmin ; Tmax

[C]

[-25;120] [-25;120] [-25;120] [-25;120]

D1D/D1S

[mm] 200/250 200/250 200/250 200/250

AC

[mm]

405

463

463

506

AD

[mm]

327

366

366

385

[mm]

450

550

550

550

B1

[mm]

198

198

198

198

B2

[mm]

555

555

555

555

B4

[mm]

198

198

198

198

B7

[mm]

572

573

573

573

B8

[mm]

260

260

260

260

B9

[mm]

295

295

295

295

C2

[mm]

525

525

525

525

C7

[mm]

460

460

460

460

C8

[mm]

50

50

50

50

[mm]

20

20

20

20

L1

[mm]

830

830

830

830

L2

[mm]

170

170

170

170

L3

[mm]

560

560

560

560

H1

[mm]

260

260

260

260

2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with

motors as standard.

89

Performance curves

DN 250
4-pole, PN 6/10/16

TP 250-XXX/4
H
[m]

TP 250

40

50 Hz

-390/4

36
32

-310/4

28
-280/4

24
20
16
12
P2
[kW]

0 100 200 300 400 500 600 700 800

Q [m/h]

70
-390/4

60
50

-310/4

40

-280/4

30
20
NPSH
[m]

0 100 200 300 400 500 600 700 800

Q [m/h]

0 100 200 300 400 500 600 700 800

Q [m/h]

8
7
6
5
4
3
2

-390/4
-280/4

-310/4

0 100 200 300 400 500 600 700 800

90

Q [m/h]

50

100

150

200

250 Q [l/s]

v [m/s]

TM02 6816 0504

Eta
[%]
85
80
75
70
65
60
55
50
45
40

Technical data

DN 250
4-pole, PN 6/10/16

H3

AC

H1

H2

D1S

D1D

B4

TM02 8349 5004

B7

B2
B1

C2
Rp 3/8

B9

C7

AD
B8

C8

C8

L2

L3
L1

Rp 3/8

Technical data
TP 250

-280/4

-310/4

-390/4

TPD

TPE

TPED

400

Series

IEC size

400

400

1-phase TP

3-phase TP

225 M

250 M

280 S

1-phase TPE

3-phase TPE

45

55

75

10

10

10

P2

[kW]

PN
Tmin ; Tmax

[C]

[-25;120] [-25;120] [-25;120]

D1D/D1S

[mm] 250/300 250/300 250/300

AC

[mm]

463

506

496

AD

[mm]

366

385

419

[mm]

550

550

550

B1

[mm]

223

223

223

B2

[mm]

635

635

635

B4

[mm]

223

223

223

B7

[mm]

647

647

647

B8

[mm]

300

300

300

B9

[mm]

335

335

335

C2

[mm]

580

580

580

C7

[mm]

520

520

520

C8

[mm]

50

50

50

[mm]

20

20

20

L1

[mm]

950

950

950

L2

[mm]

190

190

190

L3

[mm]

620

620

620

H1

[mm]

310

310

310

H2

[mm]

368

368

368

H3

[mm]

1426

1510

1574

2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with

motors as standard.

91

Performance curves

DN 125
6-pole, PN 6/10/16

TP, TPD, TPE, TPED, 6-pole, PN 16


TP, TPD 125-XXX/6
H
[m]
18

TP 125

-170/6

16

50 Hz

-140/6

14
12

-110/6
-90/6

10
8

-70/6

-60/6

4
2
P2
[kW]
8

20

40

60

80

100 120 140 Q [m/h]


-170/6

7
6

-140/6

5
4

-110/6
-90/6

-70/6

-60/6

1
0
0

20

40

60

80

100 120 140 Q [m/h]

NPSH
[m]
2.5

-140/6, -170/6

2.0

-90/6, -110/6

1.5

-60/6, -70/6

1.0
0.5
0.0
Eta
[%]
80

20

40

60

80

100 120 140 Q [m/h]


-70/6

-60/6

75
70
65

-90/6

-140/6 -170/6
-110/6

60
55
50
45
0
0
0

20

40

60

10

80

100 120 140 Q [m/h]

20
1

30
2

40

Q [l/s]

v [m/s]

TM02 8757 0904

40

Note: All QH-curves apply to single-head pumps. For further information, see page 44.

92

Technical data

B4

B4
AC

B4
P
AC

P
B3

H3

AD

H3

B1
L1

B2

D1
B2

L1

H4

D1
B1

H4

H1

H1

H2

H2

Rp 1/4

M
AE

AF

AE

AF

AE

C1

AF

C1

C5

C6

C5

TM02 8632 5004 - TM02 8631 5004

B4
AD
AD

DN 125
6-pole, PN 6/10/16

Technical data
TP 125

-60/6

-70/6

-90/6

-110/6

-140/6

-170/6

TPD

TPE

TPED

300

Series

IEC size

300

300

300

300

300

1-phase TP

3-phase TP

100

112

132

132

132

160

1-phase TPE

3-phase TPE

-/1.5

-/2.2

-/3

-/4

-/5.5

-/7.5

1-/3-phase TP

P2

[kW]

1-/3-phase TPE [kW]

PN

-/-

-/-

-/-

-/-

-/-

-/-

PN 16

PN 16

PN 16

PN 16

PN 16

PN 16

Tmin ; Tmax

[C]

D1

[mm]

125

125

125

125

125

125

[mm]

-/196

-/225

-/276

-/276

-/276

-/335

AC
AD

1-/3-phase TP

1-/3-phase TPE [mm]


1-/3-phase TP

[mm]

[-25;140] [-25;140] [-25;140] [-25;140] [-25;140] [-25;140]

-/-

-/-

-/-

-/-

-/-

-/-

-/155

-/171

-/198

-/198

-/198

-/241

1-/3-phase TPE [mm]

-/-

-/-

-/-

-/-

-/-

-/-

AE

1-/3-phase TPE [mm]

AF

1-/3-phase TPE [mm]

250

250

300

300

300

350

[mm]

B1

[mm] 202/537 202/537 243/566 243/566 243/566 243/566

[mm] 250/518 250/518 271/552 271/552 271/552 271/552

B2
B3

B4

[mm]

600

600

600

600

600

600

TP

[mm] 250/537 250/537 271/566 271/566 271/566 271/566

1-phase TPE

[mm]

3-phase TPE

[mm]

C1

[mm] 230/680 230/680 230/680 230/680 230/680 230/680

C5

[mm]

310/84

310/84

C6

[mm]

300

300

350

350

350

350

L1

[mm]

620

620

800

800

800

800

H1

[mm]

215

215

215

215

215

215

H2

[mm]

267

267

288

288

288

318

[mm]

-/787

-/810

-/923

-/961

-/961

-/1036

[mm]

-/-

-/-

-/-

-/-

-/-

-/-

[mm]

M16

M16

M16

M16

M16

M16

H3
H4
M

1-/3-phase TP

400/175 400/175 400/175 400/175

The dimension before the slash applies to the single-head pump


and the dimension after the slash applies to the twin-head pump.

93

Performance curves

DN 150
6-pole, PN 6/10/16

TP, TPD 150-XXX/6


H
[m]

TP 150

11

50 Hz

-110/6

10
9
8

-90/6

-70/6

-60/6

5
4
3
2
0

P2
[kW]

20 40 60 80 100 120 140 160 180

Q [m/h]

-110/6

5
4

-90/6

-70/6
-60/6

2
1
0
0

20 40 60 80 100 120 140 160 180

Q [m/h]

NPSH
[m]
2.5
2.0

-60/6, -70/6, -90/6, -110/6

1.5
1.0
0.5
0.0
Eta
[%]
80

20 40 60 80 100 120 140 160 180

Q [m/h]

-110/6
-70/6 -90/6

75
70

-60/6

65
60
55
50
45
40

20 40 60 80 100 120 140 160 180

10

20

0.0

0.5

1.0

30
1.5

40
2.0

50
2.5

Q [m/h]
Q [l/s]
v [m/s]

TM02 8758 0904

Note: All QH-curves apply to single-head pumps. For further information, see page 44.

94

Technical data

B4

B4
AC

B4
P
AC

P
B3

H3

AD

H3

B1
L1

B2

D1
B2

L1

H4

D1
B1

H4

H1

H1

H2

H2

Rp 1/4

M
AE

AF

AE

AF

AE

C1

AF

C1

C5

C6

C5

TM02 8632 5004 - TM02 8631 5004

B4
AD
AD

DN 150
6-pole, PN 6/10/16

Technical data
TP 150

-60/6

-70/6

-90/6

-110/6

TPD

TPE

TPED

300

Series

IEC size

300

300

300

1-phase TP

3-phase TP

112

132

132

132

1-phase TPE

3-phase TPE

-/2.2

-/3

-/4

-/5.5

1-/3-phase TP

P2

[kW]

1-/3-phase TPE [kW]

PN

-/-

-/-

-/-

-/-

PN 16

PN 16

PN 16

PN 16

Tmin ; Tmax

[C]

D1

[mm]

150

150

150

150

[mm]

-/225

-/276

-/276

-/276

AC
AD

1-/3-phase TP

1-/3-phase TPE [mm]


1-/3-phase TP

[mm]

[-25;140] [-25;140] [-25;140] [-25;140]

-/-

-/-

-/-

-/-

-/171

-/198

-/198

-/198

1-/3-phase TPE [mm]

-/-

-/-

-/-

-/-

AE

1-/3-phase TPE [mm]

AF

1-/3-phase TPE [mm]

250

300

300

300

[mm]

B1

[mm] 237/583 237/583 237/583 237/583

[mm] 296/553 296/553 296/553 296/553

B2
B3

B4

[mm]

600

600

600

600

TP

[mm] 296/583 296/583 296/583 296/583

1-phase TPE

[mm]

3-phase TPE

[mm]

C1

[mm] 230/680 230/680 230/680 230/680

C5

[mm] 400/153 400/153 400/153 400/153

C6

[mm]

350

350

350

350

L1

[mm]

800

800

800

800

H1

[mm]

215

215

215

215

H2

[mm]

275

291

291

291

[mm]

-/819

-/926

-/964

-/964

-/-

-/-

-/-

-/-

M16

M16

M16

M16

H3
H4
M

1-/3-phase TP

1-/3-phase TPE [mm]


[mm]

The dimension before the slash applies to the single-head pump


and the dimension after the slash applies to the twin-head pump.

95

Performance curves

DN 100
2-pole, PN 25

TP, 2-pole, PN 25
TP 100-XXX/2
H
[m]

H
[m]

100

-960/2

TP 100

180

50 Hz

170

90

160

-820/2

80
70

TP 100
-1680/2

50 Hz

-1530/2

150
-1400/2

-700/2

140

-620/2

120

-1180/2

110

-1050/2

130
60
50

100

40

90
30

80

20
40

80 120 160 200 240 280 320Q [m/h]

70

P2
[kW]
160

-960/2

50

-820/2
-700/2
-620/2

-1680/2
-1530/2

100

30

-1400/2
-1180/2
-1050/2

80
60

20

40

10

20

0
0

40

80 120 160 200 240 280

Q [m/h]

NPSH
[m]
10

2
0

40

80 120 160 200 240 280

Q [m/h]

Eta
[%]
80

-820/2

75

75

70

70

-960/2

65

40

80 120 160 200 240 280

Q [m/h]

40

80 120 160 200 240 280

Q [m/h]

-1680/2
-1530/2
-1050/2
-1180/2 -1400/2

60

-620/2

55

65

-700/2

60

55

50

50

45

45

40

40
40

80 120 160 200 240 280

20

40
4

60
6

Q [m/h]

80
8

Q [l/s]
10

v [m/s]

0
TM02 6830 0504

96

80 120 160 200 240 280 320Q [m/h]

120

40

Eta
[%]
80

40

140

60

NPSH
[m]
10

40

80 120 160 200 240 280

20

40
4

60
6

Q [m/h]

80
8

Q [l/s]
10

v [m/s]

TTM02 6831 0504

P2
[kW]

70
0

Technical data

DN 100
2-pole, PN 25

H3

AC

H2

H1

Rp 1/2

D1D

D1S

Rp 1/2

B9

L1

B7

TM02 8350 5004

C9

B4

B1

C3
AD

B6
C4

B5

B8

B2

Technical data
TP 100

-620/2

-700/2

-820/2

-960/2

TPD

TPE

TPED

400

Series

IEC size

-1050/2 -1180/2 -1400/2 -1530/2 -1680/2


-

400

400

400

400

400

400

400

400

1-phase TP

3-phase TP

200 L

225 M

250 M

280 S

280 S

280 M

315 S

315 M

315 L

1-phase TPE

3-phase TPE

[kW]

37

45

55

75

75

90

110

132

160

25

25

25

25

25

25

25

25

25

[C]

[0;150]

[0;150]

[0;150]

[0;150]

[0;150]

[0;150]

[0;150]

[0;150]

[0;150]

P2
PN
Tmin ; Tmax
D1D/D1S

[mm] 100/125 100/125 100/125 100/125 100/125 100/125 100/125 100/125 100/125

AC

[mm]

405

463

506

496

496

496

620

620

620

AD

[mm]

327

366

385

419

419

419

512

512

512

[mm]

550

550

550

550

550

550

800

800

800

B1

[mm]

180

180

180

180

180

180

180

180

180

B2

[mm]

407

407

407

407

425

425

425

425

425

B4

[mm]

180

180

193

227

219

219

312

312

312

B5

[mm]

360

360

360

360

360

360

360

360

360

B6

[mm]

335

335

335

335

335

335

335

335

335

B7

[mm]

467

467

467

467

475

475

600

600

600

B8

[mm]

192

192

192

192

200

200

200

200

200

B9

[mm]

215

215

215

215

225

225

225

225

225

C3

[mm]

320

320

320

320

320

320

320

320

320

C4

[mm]

295

295

295

295

295

295

295

295

295

C9

[mm]

489

489

489

489

606

606

606

606

606

[mm]

20

20

20

20

20

20

20

20

20

L1

[mm]

543

543

543

543

660

660

660

660

660

H1

[mm]

160

160

160

160

170

170

170

170

170

H2

[mm]

315

315

315

315

300

300

303

303

303

H3

[mm]

1144

1222

1306

1370

1366

1417

1427

1427

1547

2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with

motors as standard.

97

Performance curves

DN 125
2-pole, PN 25

TP 125-XXX/2
H
[m]

H
[m]

TP 125

80
75

TP 125

180

50 Hz

-750/2

160

70

-1500/2
-1310/2

140

65
60

50 Hz

-1670/2

-720/2

-580/2

120

-1160/2

100

-1060/2

55
50

80

45
40

60

35
40

30
0

P2
[kW]

50 100 150 200 250 300 350 400Q [m/h]

-750/2

70

-720/2

300

400

500

-1670/2

160

-580/2

-1310/2
-1160/2
-1060/2

80

40

Q [m/h]

-1500/2

120

50

40

30

20
0

NPSH
[m]
28

50 100 150 200 250 300 350 400Q [m/h]

100

200

300

400

500

Q [m/h]

100

200

300

400

500

Q [m/h]

24

20

16

12

2
1

Eta
[%]
90
85
80
75
70
65
60
55
50
45

50 100 150 200 250 300 350

Q [m/h]

75

-750/2

70

-720/2
-580/2

65
60
55
50
45

-1310/2
-1670/2
-1500/2
-1060/2

40

0
0

50 100 150 200 250 300 350


20

40
2

60
4

80
6

Q [m/h]

100
8

Q [l/s]
v [m/s]

0
TM02 6832 0504

98

200

200

60

Eta
[%]

100

240

80

NPSH
[m]
8

100

200
40

300

400

80
4

120
8

-1160/2

500

Q [m/h]
160 Q [l/s]
12 v [m/s]

TTM02 6833 0504

P2
[kW]

Technical data

DN 125
2-pole, PN 25

H3

AC

H2

H1

Rp 1/2

D1D

D1S

Rp 1/2

B9

L1

B7

TM02 8350 5004

C9

B4

B1

C3
AD

B6
C4

B5

B8

B2

Technical data
TP 125

-580/2

-720/2

-750/2

TPD

TPE

TPED

400

Series

IEC size

-1060/2 -1160/2 -1310/2 -1500/2 -1670/2


-

400

400

400

400

400

400

400

1-phase TP

3-phase TP

200 L

225 M

250 M

280 S

280 S

280 M

315 S

315 M

1-phase TPE

3-phase TPE

[kW]

37

45

55

75

75

90

110

132

25

25

25

25

25

25

25

25

[C]

[0;150]

[0;150]

[0;150]

[0;150]

[0;150]

[0;150]

[0;150]

[0;150]

P2
PN
Tmin ; Tmax
D1D/D1S

[mm] 100/125 100/125 100/125 100/125 100/125 100/125 100/125 100/125

AC

[mm]

405

463

506

496

496

496

620

620

AD

[mm]

327

366

385

419

419

419

512

512

[mm]

550

550

550

550

550

550

800

800

B1

[mm]

180

180

180

180

180

180

180

180

B2

[mm]

407

407

407

407

425

425

425

425

B4

[mm]

180

180

193

227

219

219

312

312

B5

[mm]

360

360

360

360

360

360

360

360

B6

[mm]

335

335

335

335

335

335

335

335

B7

[mm]

467

467

467

467

475

475

600

600

B8

[mm]

192

192

192

192

200

200

200

200

B9

[mm]

215

215

215

215

225

225

225

225

C3

[mm]

320

320

320

320

320

320

320

320

C4

[mm]

295

295

295

295

295

295

295

295

C9

[mm]

489

489

489

489

606

606

606

606

[mm]

20

20

20

20

20

20

20

20

L1

[mm]

543

543

543

543

660

660

660

660

H1

[mm]

160

160

160

160

170

170

170

170

H2

[mm]

315

315

315

315

300

300

303

303

H3

[mm]

1144

1222

1306

1370

1366

1417

1427

1427

2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with

motors as standard.

99

Performance curves

DN 100
4-pole, PN 25

TP, 4-pole, PN 25
TP 100-XXX/4
H
[m]

H
[m]

TP 100

-260/4

26
24

-380/4

36

20

-320/4

32

18

-190/4

-270/4

28

16

24

14
12

20

10

16

12
0

20 40 60 80 100 120 140 160

Q [m/h]

P2
[kW]

10

20 40 60 80 100 120 140 160

-420/4

20
-260/4

8
6

-270/4

0
0

20 40 60 80 100 120 140 160

Q [m/h]

NPSH
[m]

0
Eta
[%]
80

20 40 60 80 100 120 140 160

Q [m/h]

20 40 60 80 100 120 140 160

Q [m/h]

0
0

20 40 60 80 100 120 140 160

Q [m/h]

75

Eta
[%]
80
75

-260/4

70
65

70
65

-190/4 -220/4

60

-420/4

60

55

55

50

50

45

45

40

40
20 40 60 80 100 120 140 160

10

20
2

30
3

40
4

Q [m/h]
50 Q [l/s]

v [m/s]

-380/4

-270/4

-320/4

0
TM02 6837 0504

100

-320/4

12

-190/4

NPSH
[m]

-380/4

16
-220/4

Q [m/h]

20 40 60 80 100 120 140 160

10

20
2

30
3

40
4

Q [m/h]
50 Q [l/s]

6v [m/s]

TM02 6838 0504

P2
[kW]

50 Hz

-420/4

40

-220/4

22

TP 100

44

50 Hz

Technical data

DN 100
4-pole, PN 25

H3

AC

H2

H1

Rp 1/2

D1D

D1S

Rp 1/2

B9

L1

B7

TM02 8350 5004

C9

B4

B1

C3
AD

B6
C4

B5

B8

B2

Technical data
TP 100

-190/4

-220/4

-260/4

-270/4

-320/4

-380/4

-420/4

TPD

TPE

TPED

400

Series

IEC size

400

400

400

400

400

400

1-phase TP

3-phase TP

132 S

132 M

160 M

160 M

160 L

180 M

180 L

1-phase TPE

3-phase TPE

[kW]

5.5

7.5

11

11

15

18.5

22

25

25

25

25

25

25

25

[C]

[0;150]

[0;150]

[0;150]

[0;150]

[0;150]

[0;150]

[0;150]

P2
PN
Tmin ; Tmax
D1D/D1S

[mm] 100/125 100/125 100/125 100/125 100/125 100/125 100/125

AC

[mm]

260

260

335

335

335

366

366

AD

[mm]

197

197

245

245

245

266

266

[mm]

400

400

400

450

450

450

450

B1

[mm]

180

180

180

180

180

180

180

B2

[mm]

407

407

407

425

425

425

425

B4

[mm]

180

180

180

180

180

180

180

B5

[mm]

360

360

360

360

360

360

360

B6

[mm]

335

335

335

335

335

335

335

B7

[mm]

401

401

401

429

430

429

429

B8

[mm]

192

192

192

200

200

200

200

B9

[mm]

215

215

215

225

225

225

225

C3

[mm]

320

320

320

320

320

320

320

C4

[mm]

295

295

295

295

295

295

295

C9

[mm]

489

489

489

606

606

606

606

[mm]

20

20

20

20

20

20

20

L1

[mm]

543

543

543

660

660

660

660

H1

[mm]

160

160

160

170

170

170

170

H2

[mm]

285

285

285

270

270

270

270

H3

[mm]

864

902

947

942

987

1042

1042

2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with

motors as standard.

101

Performance curves

DN 125
4-pole, PN 25

TP 125-XXX/4
H
[m]

H
[m]

TP 125

-240/4

24
22

TP 125

45

50 Hz

40

-200/4

-370/4

20

35

18

-310/
4

30

16

50 Hz

-430/4

-150/4

-280/4

25

14
20

12
15

10

10

8
0

40

80

120

160

200

P2
[kW]

Q [m/h]

12

-430/4
-370/4
-310/4

15

-280/4

10

-150/4

2
0

40

80

120

160

200

NPSH
[m]

Q [m/h]

40

80

120 160 200 240 280 Q [m/h]

40

80

120 160 200 240 280 Q [m/h]

3.0

2.5

2.0

1.5

1.0

0.5

Eta
[%]
80

40

80

120

160

200

Q [m/h]

-430/4
-370/4

75

75

70

-200/4 -240/4

65

70

60

-150/4

65

-280/4

55

60

50

55

-310/4

45

50

40

45

40
40

0
0

80

120

20
1

160

200

40
2

60
4

Q [m/h]
Q [l/s]
5v [m/s]

40

0
TM02 6839 0504

102

120 160 200 240 280 Q [m/h]

20
-200/4

Eta
[%]
80

80

25

10

NPSH
[m]

40

30

-240/4

14

80

120 160 200 240 280 Q [m/h]

20
1

40
2

60
4

80

Q [l/s]

v [m/s]

TM02 6840 0805

P2
[kW]

Technical data

DN 125
4-pole, PN 25

H3

AC

H2

H1

Rp 1/2

D1D

D1S

Rp 1/2

B9

L1

B7

TM02 8350 5004

C9

B4

B1

C3
AD

B6
C4

B5

B8

B2

Technical data
TP 125

-150/4

-200/4

-240/4

-280/4

-310/4

-370/4

-430/4

TPD

TPE

TPED

400

Series

IEC size

400

400

400

400

400

400

1-phase TP

3-phase TP

132 M

160 M

160 L

160 L

180 M

180 L

200 L

1-phase TPE

3-phase TPE

[kW]

7.5

11

15

15

18.5

22

30

25

25

25

25

25

25

25

[C]

[0;150]

[0;150]

[0;150]

[0;150]

[0;150]

[0;150]

[0;150]

P2
PN
Tmin ; Tmax
D1D/D1S

[mm] 125/150 125/150 125/150 125/150 125/150 125/150 125/150

AC

[mm]

260

335

335

335

366

366

405

AD

[mm]

197

245

245

245

266

266

327

[mm]

400

400

400

450

450

450

450

B1

[mm]

200

200

200

200

200

200

200

B2

[mm]

430

430

430

451

451

451

451

B4

[mm]

200

200

200

200

200

200

200

B5

[mm]

400

400

400

400

400

400

400

B6

[mm]

360

360

360

360

360

360

360

B7

[mm]

423

423

423

467

468

468

467

B8

[mm]

200

200

200

224

224

224

224

B9

[mm]

230

230

230

227

227

227

227

C3

[mm]

360

360

360

360

360

360

360

C4

[mm]

320

320

320

320

320

320

320

C9

[mm]

536

536

536

606

606

606

606

[mm]

20

20

20

20

20

20

20

L1

[mm]

590

590

590

660

660

660

660

H1

[mm]

185

185

185

180

180

180

180

H2

[mm]

287

287

287

283

283

283

283

H3

[mm]

930

974

1019

1010

1065

1065

1132

2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with

motors as standard.

103

Performance curves

DN 150
4-pole, PN 25

TP 150-XXX/4
H
[m]

TP 150

-650/4

65

50 Hz

60
55

-530/4

50
45

-430/4

40
-350/4

35

-320/4

30

-270/4

25
-240/4

20
15
10
P2
[kW]

50 100 150 200 250 300 350 400 450Q [m/h]

70

-650/4

60
-530/4

50

-430/4

40

-350/4
-320/4
-270/4
-240/4

30
20
10
0
NPSH
[m]

50 100 150 200 250 300 350 400 450Q [m/h]

50 100 150 200 250 300 350 400 450Q [m/h]

7
6
5
4
3
2
1

-320/4

-430/4
-530/4
-270/4

104

-350/4

-240/4

-650/4

50 100 150 200 250 300 350 400 450Q [m/h]

20

40

60

80
4

100
5

120
6

Q [l/s]
7v [m/s]

TM02 6842 0504

Eta
[%]
85
80
75
70
65
60
55
50
45
40

Technical data

DN 150
4-pole, PN 25

H3

AC

H2

H1

Rp 1/2

D1D

D1S

Rp 1/2

B9

L1

B7

TM02 8350 5004

C9

B4

B1

C3
AD

B6
C4

B5

B8

B2

Technical data
TP 150

-240/4

-270/4

-320/4

-350/4

-430/4

-530/4

-650/4

TPD

TPE

TPED

400

Series

IEC size

400

400

400

400

400

400

1-phase TP

3-phase TP

180 M

180 L

200 L

225 S

225 M

250 M

280 S

1-phase TPE

3-phase TPE

[kW]

18.5

22

30

37

45

55

75

25

25

25

25

25

25

25

[C]

[0;150]

[0;150]

[0;150]

[0;150]

[0;150]

[0;150]

[0;150]

P2
PN
Tmin ; Tmax
D1D/D1S

[mm] 150/200 150/200 150/200 150/200 150/200 150/200 150/200

AC

[mm]

366

366

405

463

463

506

496

AD

[mm]

266

266

327

366

366

385

419

[mm]

450

450

450

550

550

550

550

B1

[mm]

230

230

230

230

235

235

235

B2

[mm]

504

504

504

504

575

575

575

B4

[mm]

230

230

230

230

235

235

235

B5

[mm]

460

460

460

460

470

470

470

B6

[mm]

400

400

400

400

410

410

410

B7

[mm]

517

517

518

518

584

584

584

B8

[mm]

229

229

229

229

260

260

260

B9

[mm]

275

275

275

275

315

315

315

C3

[mm]

420

420

420

420

420

420

420

C4

[mm]

360

360

360

360

360

360

360

C9

[mm]

676

676

676

676

823

823

823

[mm]

20

20

20

20

20

20

20

L1

[mm]

740

740

740

740

900

900

900

H1

[mm]

225

225

225

225

250

250

250

H2

[mm]

293

293

293

323

325

325

325

H3

[mm]

1120

1120

1187

1296

1322

1406

1470

2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with

motors as standard.

105

Performance curves

DN 200
4-pole, PN 25

TP 200-XXX/4
H
[m]

H
[m]

40

TP 200

-420/4

65

50 Hz

25

55
50

-280/4

45
40

15

35

10

30

25

20
0

100

200

300

400

500

600 Q [m/h]

P2
[kW]

-420/4

50

30

0
200

300

400

500

200

300

400

500

600 Q [m/h]

-620/4
-560/4
-510/4
-450/4

20

100

100

40

10

60

600 Q [m/h]

NPSH
[m]

100

200

300

400

500

600 Q [m/h]

100

200

300

400

500

600 Q [m/h]

6
5

0
0

100

200

300

400

500

600 Q [m/h]

Eta
[%]
90
85
80
75
70
65
60
55
50
45

75
70

-420/4

65
60

-380/4

55
50

-260/4

45

-280/4

40
100

0
0

200
50

300

400

500

100
2

150

Q [l/s]

6v [m/s]

-620/4
-560/4

-510/4
-450/4

600 Q [m/h]
TM02 6843 0805

106

-450/4

80

-280/4
-260/4

20

Eta
[%]
80

-510/4

100

-380/4

40

NPSH
[m]

-560/4

-260/4

20

P2
[kW]

50 Hz

60

-380/4

35
30

TP 200

-620/4

100

0
0

200
50

300

400

500

100
2

600 Q [m/h]

150

Q [l/s]

6v [m/s]

TM02 6844 0504

45

Technical data

DN 200
4-pole, PN 25

H3

AC

H2

H1

Rp 1/2

D1D

D1S

Rp 1/2

B9

L1

B7

TM02 8350 5004

C9

B4

B1

C3
AD

B6
C4

B5

B8

B2

Technical data
TP 200

-270/4

-280/4

-380/4

-420/4

-450/4

-510/4

-560/4

-620/4

TPD

TPE

TPED

400

Series

IEC size

400

400

400

400

400

400

400

1-phase TP

3-phase TP

200 L

225 S

225 M

250 M

250 M

280 S

280 M

315 S

1-phase TPE

3-phase TPE

[kW]

30

37

45

55

55

75

90

110

25

25

25

25

25

25

25

25

[C]

[0;150]

[0;150]

[0;150]

[0;150]

[0;150]

[0;150]

[0;150]

[0;150]

P2
PN
Tmin ; Tmax
D1D/D1S

[mm] 200/250 200/250 200/250 200/250 200/250 200/250 200/250 200/250

AC

[mm]

405

463

463

506

506

496

496

620

AD

[mm]

327

366

366

385

385

419

419

512

[mm]

450

550

550

550

550

550

550

660

B1

[mm]

260

260

260

260

268

268

268

268

B2

[mm]

560

560

560

560

640

640

640

640

B4

[mm]

260

260

260

260

268

268

268

268

B5

[mm]

520

520

520

520

535

535

535

535

B6

[mm]

460

460

460

460

470

470

470

470

B7

[mm]

572

572

572

572

645

645

645

645

B8

[mm]

260

260

260

260

300

300

300

300

B9

[mm]

300

300

300

300

340

340

340

340

C3

[mm]

480

480

480

480

485

485

485

485

C4

[mm]

420

420

420

420

420

420

420

420

C9

[mm]

766

766

766

766

1013

1013

1013

1013

[mm]

20

20

20

20

20

20

20

20

L1

[mm]

830

830

830

830

1100

1100

1100

1100

H1

[mm]

250

250

250

250

290

290

290

290

H2

[mm]

308

338

338

338

327

327

327

357

H3

[mm]

1227

1336

1336

1420

1449

1513

1564

1601

2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with

motors as standard.

107

Performance curves

DN 250
4-pole, PN 25

TP 250-XXX/4
H
[m]

H
[m]

TP 250

40

70

50 Hz

-370/4

65

36

28

-270/4

-540/4

50

-490/4

40

20

35

16

30

12

25

20
0 100 200 300 400 500 600 700 800

Q [m/h]

P2
[kW]

-370/4

-660/4

120

50

-320/4

40

-600/4

100

-540/4
-490/4

80

-270/4

30

60

20

40
0 100 200 300 400 500 600 700 800

Q [m/h]

NPSH
[m]

0 100 200 300 400 500 600 700 800

Q [m/h]

0 100 200 300 400 500 600 700 800

Q [m/h]

0
0 100 200 300 400 500 600 700 800

Q [m/h]

Eta
[%]
80

-270/4

-600/4

75
-370/4

70
-490/4

65

-320/4

-660/4
-540/4

60
55
50
45
40
Q [m/h]

50

100

150

200

250 Q [l/s]

v [m/s]

0 100 200 300 400 500 600 700 800

Q [m/h]

50

100

150

200

250 Q [l/s]

v [m/s]

TM02 6846 0504

0 100 200 300 400 500 600 700 800

TM02 6845 0504

Eta
[%]
85
80
75
70
65
60
55
50
45
40

Q [m/h]

140

60

NPSH
[m]

0 100 200 300 400 500 600 700 800

160

70

108

55

45

24

P2
[kW]

50 Hz

-600/4

60

-320/4

32

TP 250

-660/4

Technical data

DN 250
4-pole, PN 25

H3

AC

H2

H1

Rp 1/2

D1D

D1S

Rp 1/2

B9

L1

B7

TM02 8350 5004

C9

B4

B1

C3
AD

B6
C4

B5

B8

B2

Technical data
TP 250

-270/4

-320/4

-370/4

-490/4

-540/4

-600/4

-660/4

TPD

TPE

TPED

400

Series

IEC size

400

400

400

400

400

400

1-phase TP

3-phase TP

225 M

250 M

280 S

280 M

315 S

315 M

315 M

1-phase TPE

3-phase TPE

[kW]

45

55

75

90

110

132

160

25

25

25

25

25

25

25

[C]

[0;150]

[0;150]

[0;150]

[0;150]

[0;150]

[0;150]

[0;150]

P2
PN
Tmin ; Tmax
D1D/D1S

[mm] 250/300 250/300 250/300 250/300 250/300 250/300 250/300

AC

[mm]

463

506

496

496

620

620

620

AD

[mm]

366

385

419

419

512

512

512

[mm]

550

550

550

660

660

660

660

B1

[mm]

303

303

303

303

303

303

303

B2

[mm]

650

650

650

700

700

700

700

B4

[mm]

303

303

303

303

303

303

303

B5

[mm]

605

605

605

605

605

605

605

B6

[mm]

540

540

540

540

540

540

540

B7

[mm]

647

647

647

720

720

720

720

B8

[mm]

300

300

300

330

330

330

330

B9

[mm]

350

350

350

370

370

370

370

C3

[mm]

550

550

550

550

550

550

550

C4

[mm]

485

485

485

485

485

485

485

C9

[mm]

855

855

855

1106

1106

1106

1106

[mm]

24

24

24

24

24

24

24

L1

[mm]

950

950

950

1200

1200

1200

1200

H1

[mm]

300

300

300

350

350

350

350

H2

[mm]

368

368

368

373

373

358

358

H3

[mm]

1416

1500

1564

1670

1677

1662

1662

2- and 4-pole TP and TPD pumps from 1.1 to 90 kW are fitted with

motors as standard.

109

Performance curves

DN 300
4-pole, PN 25

TP 300-XXX/4
H
[m]

TP 300

-750/4

75

50 Hz

70

-670/4

65
-590/4

60
55
50
45
40
35
30
25
P2
[kW]

400

800

1200

1600

Q [m/h]

300

-750/4

250
-670/4

200

-590/4

150
100
50
NPSH
[m]

400

800

1200

1600

Q [m/h]

400

800

1200

1600

Q [m/h]

14
12
10
8
6
4
2
Eta
[%]
85
80
-750/4

75

-590/4

70

-670/4

65
60
55
50
45

0
0

110

400
100

800
200

1200
300
4

1600
400
6

500

Q [m/h]
Q [l/s]
8v [m/s]

TM02 6847 0504

Technical data

DN 300
4-pole, PN 25

H3

AC

H2

H1

Rp 1/2

D1D

D1S

Rp 1/2

B9

L1

TM02 8350 5004

B7
B4

B1

C3
AD

B6
C4

C9

B5

B8

B2

Technical data
TP 300

-590/4

-670/4

-750/4

TPD

TPE

TPED

400

Series

IEC size

400

400

1-phase TP

3-phase TP

315 L

315

315

1-phase TPE

3-phase TPE

[kW]

200

250

315

25

25

25

[C]

[0;150]

[0;150]

[0;150]

P2
PN
Tmin ; Tmax
D1D/D1S

[mm] 300/350 300/350 300/350

AC

[mm]

620

710

AD

[mm]

512

690

690

[mm]

660

1150

1150

B1

[mm]

338

338

338

B2

[mm]

790

790

790

B4

[mm]

338

338

338

B5

[mm]

675

675

675

B6

[mm]

605

605

605

B7

[mm]

817

817

817

B8

[mm]

370

370

370

B9

[mm]

420

420

420

C3

[mm]

620

620

620

C4

[mm]

550

550

550

C9

[mm]

1204

1204

1204

710

[mm]

24

24

24

L1

[mm]

1300

1300

1300

H1

[mm]

375

375

375

H2

[mm]

406

446

446

H3

[mm]

1855

2051

2051

111

Performance curves

DN 400
4-pole, PN 25

TP 400-XXX/4
H
[m]

H
[m]

55

-540/4

50
45

TP 400

80

50 Hz

75

-510/4

70

-470/4

65

40

55

30

50
40

20

35

15

30

10

25
0

500 1000 1500 2000 2500 3000 3500 Q [m/h]

P2
[kW]

-540/4
-470/4

1600 2400

3200 4000

Q [m/h]

-760/4
-720/4
-670/4

400

200

300

100

200

100
0

500 1000 1500 2000 2500 3000 3500 Q [m/h]

NPSH
[m]
16

12

800

1600 2400

3200 4000

Q [m/h]

800

1600 2400

3200 4000

Q [m/h]

14

10

12

10

4
2
0

500 1000 1500 2000 2500 3000 3500 Q [m/h]

75

-470/4

70

Eta
[%]
85
80
75
70
65
60
55
50
45
40

-540/4
-510/4

65
60
55
50
45
40

0
0

500 1000 1500 2000 2500 3000 3500 Q [m/h]


200
2

400

600
4

800
6

1000 Q [l/s]
8 v [m/s]

-720/4
-760/4

0
TM02 6848 0504

-670/4

800

0
0

1600 2400
400

3200 4000

800
4

Q [m/h]

1200
8

Q [l/s]

10 v [m/s]

TM02 6849 0504

112

800

500

-510/4

300

Eta
[%]
80

600

400

NPSH
[m]
14

-670/4

45

25

P2
[kW]

50 Hz

-720/4

60

35

TP 400

-760/4

Technical data

DN 400
4-pole, PN 25

H3

P
AC

H1

H2

Rp 1/2

D1D

Rp 1/2

D1S

TM02 8351 5004

B1
AD

C9

B4

C3
B5

B6
C4

B8

B2

B7

B9

L1

Technical data
TP 400
TPD
TPE

-470/4

-510/4

-540/4

-670/4

-720/4

-760/4

TP 400-470/4 TP 400-510/4 TP 400-540/4 TP 400-670/4 TP 400-720/4 TP 400-760/4

TPED

Series

IEC size

1-phase TP

3-phase TP

400

400

400

400

400

400

1-phase TPE

3-phase TPE

315

355

355

355

400

400

P2

[kW]

PN

630

Tmin ; Tmax

[C]

315

355

400

500

560

D1D/D1S

[mm]

25

25

25

25

25

25

AC

[mm]

[0;150]

[0;150]

[0;150]

[0;150]

[0;150]

[0;150]

AD

[mm]

400/500

400/500

400/500

400/500

400/500

400/500

[mm]

710

790

790

790

880

880

B1

[mm]

690

725

725

875

925

925

B2

[mm]

1150

900

900

900

1150

1150

B4

[mm]

448

448

448

448

448

448

B5

[mm]

1064

1064

1064

1064

1064

1064

B6

[mm]

448

448

448

448

448

448

B7

[mm]

895

895

895

895

895

895

B8

[mm]

800

800

800

800

800

800

B9

[mm]

1066

1066

1066

1066

1066

1066

C3

[mm]

830

830

830

830

830

830

C4

[mm]

735

735

735

735

735

735

C9

[mm]

1302

1302

1302

1302

1302

1302

[mm]

27

27

27

27

27

27

L1

[mm]

1400

1400

1400

1400

1400

1400

H1

[mm]

450

450

450

450

450

450

H2

[mm]

706

706

706

706

706

706

H3

[mm]

2386

2611

2611

2611

2771

2771

113

Weights and shipping volume

TP, TPD, TPE, TPED

TP, TPD, TPE, TPED, 2-pole, PN 6/10/16


Connection
Pump type

114

Weights
Net [kg]

Shipping volume [m3]

Gross [kg]

D1D

D1S

TP/TPD

TPE/TPED

TP/TPD

TPE/TPED

TP/TPD

TP 25-50/2 R

7.2/-

8.2/-

0.020/-

TP 25-90/2 R

7.5/-

10.7/-

8.5/-

12.7/-

0.020/-

0.036/-

TPE/TPED

TP 32-50 /2 R

G2

G2

7.8/-

8.8/-

0.020/-

TP 32-90/2 R

G2

G2

8.2/-

11.8/-

9.2/-

13.8/-

0.020/-

0.036/-

TP, TPD 32-60/2

DN 32

DN 32

15.9/31.8

22.1/39.3

16.9/32.8

25.3/42.7

0.036/0.072

0.064/0.151

TP, TPD 32-120/2

DN 32

DN 32

19.2/38.0

21.3/42.2

20.2/40.0

22.3/44.2

0.036/0.072

0.056/0.072

TP, TPD 32-150/2

DN 32

DN 32

22.8/54.0

29.3/58.5

26.0/57.0

32.5/61.9

0.064/0.082

0.064/0.151

TP, TPD 32-180/2

DN 32

DN 32

24.1/54.0

29.0/58.9

27.3/57.0

32.2/61.9

0.064/0.082

0.064/0.082

TP, TPD 32-230/2

DN 32

DN 32

24.7/54.0

41.3/81.4

27.9/57.0

44.5/85.4

0.064/0.082

0.091/0.221

TP, TPD 32-200/2

DN 32

DN 32

43.7/88.5

49.8/100.6

48.7/105.0

61.7/117.9

0.125/0.346

0.138/0.497

TP, TPD 32-250/2

DN 32

DN 32

45.9/92.9

51.9/104.6

50.9/109.4

57.4/123.3

0.125/0.346

0.138/0.391

TP, TPD 32-320/2

DN 32

DN 32

51.3/103.7

56.6/114.0

56.6/120.2

62.1/132.7

0.125/0.346

0.152/0.495

TP, TPD 32-380/2

DN 32

DN 32

62.9/126.9

64.6/130.0

68.2/144.3

70.1/148.6

0.125/0.413

0.184/0.497

TP, TPD 32-460/2

DN 32

DN 32

75.6/151.2

78.7/157.1

82.0/168.6

85.4/175.7

0.193/0.413

0.218/0.497

TP, TPD 32-580/2

DN 32

DN 32

90.3/180.4

94.8/189.4

105.5/197.9

113.4/208.0

0.236/0.413

0.218/0.497

TP 40-50/2

DN 40

DN 40

11.5/-

12.5/-

0.020/-

TP, TPD 40-60/2

DN 40

DN 40

20.2/42.0

22.8/47.6

21.2/43.0

25.3/51.6

0.036/0.072

0.056/0.072

TP 40-90/2

DN 40

DN 40

12.0/-

17.3/-

13.0/-

18.3/-

0.020/-

0.025/-

TP, TPD 40-120/2

DN 40

DN 40

19.7/40.5

22.3/45.7

20.7/42.5

24.3/49.7

0.036/0.072

0.056/0.072

TP 40-180/2

DN 40

DN 40

23.5/-

28.7/-

24.5/-

31.9/-

0.036/-

0.064/-

TP, TPD 40-190/2

DN 40

DN 40

28.8/53.8

44.2/81.6

32.0/59.3

47.6/87.1

0.064/0.151

0.091/0.221

TP, TPD 40-230/2

DN 40

DN 40

37.3/57.2

45.8/80.7

40.4/62.7

49.2/86.2

0.064/0.151

0.091/0.221

TP, TPD 40-270/2

DN 40

DN 40

38.9/69.5

36.7/74.9

42.1/75.0

40.1/80.4

0.064/0.151

0.091/0.221

TP, TPD 40-240/2

DN 40

DN 40

53.1/107.3

58.3/117.7

58.3/123.8

63.8/136.3

0.125/0.346

0.152/0.495

TP, TPD 40-300/2

DN 40

DN 40

64.5/130.1

66.2/133.4

69.7/147.6

71.7/152.1

0.125/0.413

0.184/0.497

TP, TPD 40-360/2

DN 40

DN 40

69.6/140.3

72.6/146.2

74.8/157.8

78.1/164.9

0.125/0.413

0.184/0.497

TP, TPD 40-470/2

DN 40

DN 40

90.2/183.2

94.7/192.1

105.4/200.7

113.3/210.8

0.236/0.413

0.218/0.497

TP, TPD 40-580/2

DN 40

DN 40

92.1/187.0

96.2/195.1

107.3/204.3

114.8/213.8

0.236/0.413

0.218/0.497

TP, TPD 50-60/2

DN 50

DN 50

20.2/45.0

24.4/49.5

21.2/48.0

27.6/52.9

0.056/0.072

0.064/0.151

TP, TPD 50-120/2

DN 50

DN 50

28.2/56.3

39.8/83.4

29.2/58.3

40.8/85.4

0.056/0.072

0.091/0.221

TP, TPD 50-180/2

DN 50

DN 50

27.7/55.8

41.4/83.1

28.7/57.8

44.6/86.5

0.056/0.072

0.091/0.221

TP, TPD 50-160/2

DN 50

DN 50

46.7/94.0

52.7/105.9

51.7/110.5

64.6/123.3

0.125/0.346

0.138/0.391

TP, TPD 50-190/2

DN 50

DN 50

48.8/98.2

54.8/110.0

53.8/114.7

60.3/128.6

0.125/0.346

0.152/0.495

TP, TPD 50-240/2

DN 50

DN 50

54.1/108.8

59.4/119.2

59.4/125.3

64.9/137.8

0.125/0.346

0.152/0.495

TP, TPD 50-290/2

DN 50

DN 50

65.5/131.6

67.3/134.9

70.8/149.1

72.8/153.6

0.125/0.413

0.184/0.497

TP, TPD 50-360/2

DN 50

DN 50

71.6/144.2

74.6/150.1

76.8/161.7

80.1/168.8

0.125/0.413

0.184/0.497

TP, TPD 50-430/2

DN 50

DN 50

86.4/174.0

91.0/182.9

101.7/191.4

109.5/201.5

0.236/0.413

0.184/0.497

TP, TPD 50-440/2

DN 50

DN 50

100.2/204.4

104.3/212.5

115.4/223.6

122.9/231.2

0.236/0.470

0.218/0.497

TP, TPD 50-570/2

DN 50

DN 50

147.9/299.8

184.0/372.0

164.9/320.9

202.6/398.2

0.312/0.596

0.424/0.930

TP, TPD 50-710/2

DN 50

DN 50

159.7/323.4

201.8/407.6

176.7/344.5

220.4/433.8

0.312/0.596

0.424/0.930

TP, TPD 50-830/2

DN 50

DN 50

169.9/343.8

245.0/494.0

186.9/364.9

263.6/520.2

0.312/0.596

0.424/0.930

TP, TPD 50-900/2

DN 50

DN 50

199.0/402.1

276.1/556.2

217.6/428.3

294.7/582.4

0.424/0.930

0.424/0.930

TP, TPD 65-60/2

DN 65

DN 65

26.7/53.0

30.4/59.6

27.7/56.0

33.6/63.0

0.056/0.140

0.064/0.151

TP, TPD 65-120/2

DN 65

DN 65

32.6/66.6

40.6/86.6

34.6/69.6

42.6/90.6

0.056/0.140

0.091/0.221

TP, TPD 65-180/2

DN 65

DN 65

38.0/76.9

45.8/92.5

41.0/79.9

48.8/95.5

0.066/0.140

0.091/0.221

TP, TPD 65-190/2

DN 65

DN 65

57.9/116.4

63.1/126.7

63.1/132.9

68.7/145.3

0.125/0.346

0.184/0.391

TP, TPD 65-230/2

DN 65

DN 65

69.3/139.2

71.0/142.5

74.5/156.6

76.6/161.1

0.125/0.413

0.184/0.497

TP, TPD 65-260/2

DN 65

DN 65

74.3/149.2

77.3/155.1

79.5/166.6

82.9/173.7

0.125/0.413

0.184/0.497

TP, TPD 65-340/2

DN 65

DN 65

89.2/178.9

93.7/187.8

104.4/196.4

112.3/206.5

0.236/0.413

0.184/0.497
0.184/0.497

TP, TPD 65-410/2

DN 65

DN 65

91.1/182.7

95.2/190.8

106.3/200.2

113.8/209.5

0.236/0.413

TP, TPD 65-460/2

DN 65

DN 65

149.4/306.4

185.5/378.5

166.4/327.4

204.1/404.8

0.312/0.596

0.424/0.930

TP, TPD 65-550/2

DN 65

DN 65

160.7/329.0

202.8/413.1

177.7/350.0

221.4/439.4

0.312/0.596

0.424/0.930

TP, TPD 65-660/2

DN 65

DN 65

170.9/349.4

246.0/499.5

187.9/370.4

264.6/525.8

0.312/0.596

0.424/0.930

TP, TPD 65-720/2

DN 65

DN 65

200.6/408.8

277.8/562.9

219.2/435.0

296.3/589.2

0.424/0.930

0.424/0.930

TP, TPD 65-930/2

DN 65

DN 65

290.9/589.5

309.5/615.7

0.424/0.930

TP, TPD 80-120/2

DN 80

DN 80

43.5/83.0

52.6/100.7

44.5/86.0

57.1/106.7

0.066/0.140

0.091/0.370

TP, TPD 80-140/2

DN 80

DN 80

61.0/124.0

66.5/134.0

74.0/141.0

78.5/151.0

0.184/0.391

0.184/0.458

Weights and shipping volume

Connection
Pump type

TP, TPD, TPE, TPED

Weights
Net [kg]

Shipping volume [m3]

Gross [kg]

D1D

D1S

TP/TPD

TPE/TPED

TP/TPD

TPE/TPED

TP/TPD

TPE/TPED

TP, TPD 80-180/2

DN 80

DN 80

65.0/132.0

74.5/150.0

78.0/149.0

88.5/180.0

0.184/0.458

0.184/0.458

TP, TPD 80-210/2

DN 80

DN 80

78.0/157.0

80.7/162.4

90.0/174.0

94.7/192.4

0.184/0.458

0.184/0.497

TP, TPD 80-240/2

DN 80

DN 80

93.0/187.0

97.6/195.2

105.0/204.0

118.6/225.2

0.184/0.458

0.184/0.497
0.533/0.497

TP, TPD 80-250/2

DN 80

DN 80

101.0/211.0

105.8/218.6

115.0/230.0

126.8/248.6

0.218/0.497

TP, TPD 80-330/2

DN 80

DN 80

148.0/304.0

184.0/376.0

169.0/334.0

206.0/426.0

0.533/0.653

0.533/1.524

TP, TPD 80-400/2

DN 80

DN 80

160.0/327.0

202.0/411.0

180.0/356.0

222.0/459.0

0.533/0.653

0.533/1.524

TP, TPD 80-520/2

DN 80

DN 80

176.0/349.0

251.0/499.0

197.0/379.0

272.0/549.0

0.533/0.653

0.533/1.524

TP, TPD 80-570/2

DN 80

DN 80

205.0/407.0

282.0/561.0

226.0/457.0

303.0/611.0

0.533/1.524

0.533/1.524

TP, TPD 80-700/2

DN 80

DN 80

295.0/587.0

316.0/637.0

0.533/1.524

TP, TPD 100-120/2

DN 100

DN 100

53.0/108.5

61.1/124.7

55.0/113.5

66.1/130.7

0.140/0.213

0.120/0.370

TP, TPD 100-160/2

DN 100

DN 100

93.0/196.0

95.7/202.4

107.0/246.0

109.7/252.4

0.267/1.524

0.218/1.524

TP, TPD 100-200/2

DN 100

DN 100

108.0/226.0

112.6/235.2

122.0/276.0

134.6/285.2

0.267/1.524

0.267/1.524
0.267/1.524

TP, TPD 100-240/2

DN 100

DN 100

110.0/230.0

117.0/244.0

124.0/280.0

139.0/294.0

0.267/1.524

TP, TPD 100-250/2

DN 100

DN 100

173.0/347.0

209.0/419.0

197.0/397.0

233.0/469.0

0.630/1.524

0.630/1.524

TP, TPD 100-310/2

DN 100

DN 100

184.0/370.0

226.0/454.0

208.0/420.0

250.0/504.0

0.630/1.524

0.630/1.524

TP, TPD 100-360/2

DN 100

DN 100

195.0/390.0

270.0/540.0

218.0/440.0

293.0/590.0

0.630/1.524

0.630/1.524

TP, TPD 100-390/2

DN 100

DN 100

224.0/449.0

301.0/603.0

247.0/499.0

324.0/653.0

0.630/1.524

0.630/1.524

TP, TPD 100-480/2

DN 100

DN 100

329.0/661.0

0.797/1.800

The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

115

Weights and shipping volume

TP, TPD, TPE, TPED

TP, TPD, TPE, TPED, 4-pole, PN 6/10/16


Connection
Pump type

116

Weights
Net [kg]

Gross [kg]

Shipping volume [m3]

D1D

D1S

TP/TPD

TPE/TPED

TP/TPD

TPE/TPED

TP/TPD

TPE/TPED

TP, TPD 32-30/4

DN 32

DN 32

15.9/30.8

21.7/38.8

16.9/31.8

24.9/42.2

0.036/0.072

0.064/0.151

TP, TPD 32-40/4

DN 32

DN 32

25.2/32.0

29.1/54.7

28.4/33.0

32.3/58.1

0.064/0.072

0.064/0.151

TP, TPD 32-60/4

DN 32

DN 32

25.2/50.7

29.1/54.7

28.4/53.7

32.3/58.1

0.036/0.082

0.064/0.151

TP, TPD 32-80/4

DN 32

DN 32

35.2/69.9

36.9/74.9

40.2/86.4

48.8/92.2

0.125/0.346

0.184/0.391

TP, TPD 32-100/4

DN 32

DN 32

36.3/71.7

37.2/75.5

41.2/88.3

49.1/92.8

0.125/0.346

0.184/0.391

TP, TPD 32-120/4

DN 32

DN 32

49.7/94.2

48.3/96.5

55.8/110.7

61.1/113.8

0.162/0.346

0.218/0.391
0.064/0.151

TP, TPD 40-30/4

DN 40

DN 40

17.4/33.0

23.3/41.3

18.4/34.3

26.5/44.7

0.036/0.072

TP 40-60/4

DN 40

DN 40

22.5/42.0

27.2/-

23.5/43.0

30.4/-

0.036/0.072

0.064/-

TP, TPD 40-90/4

DN 40

DN 40

28.9/50.9

32.8/49.3

32.3/56.4

36.0/54.8

0.076/0.151

0.076/0.151
0.184/0.391

TP, TPD 40-100/4

DN 40

DN 40

41.0/83.1

42.2/85.6

45.9/99.6

54.1/103.0

0.125/0.346

TP, TPD 40-130/4

DN 40

DN 40

48.4/99.6

58.6/120.0

54.4/116.1

71.4/137.4

0.162/0.346

0.218/0.391

TP, TPD 40-160/4

DN 40

DN 40

54.5/112.0

64.5/131.7

60.6/128.5

71.2/150.3

0.162/0.346

0.231/0.495

TP, TPD 50-30/4

DN 50

DN 50

24.4/46.3

30.3/51.9

25.4/48.3

33.5/55.3

0.036/0.072

0.064/0.151

TP, TPD 50-60/4

DN 50

DN 50

25.5/50.5

28.5/56.4

26.5/52.5

30.5/61.9

0.056/0.072

0.056/0.072

TP, TPD 50-90/4

DN 50

DN 50

43.0/87.0

44.2/89.5

47.9/103.5

56.1/106.9

0.125/0.346

0.184/0.391

TP, TPD 50-110/4

DN 50

DN 50

56.5/117.1

66.7/137.5

62.5/136.3

79.5/167.5

0.162/0.470

0.218/0.497

TP, TPD 50-130/4

DN 50

DN 50

62.7/129.4

72.6/149.1

68.7/148.6

79.4/167.8

0.162/0.470

0.218/0.497

TP, TPD 50-160/4

DN 50

DN 50

65.1/134.2

73.9/151.7

71.1/153.4

80.7/170.4

0.162/0.470

0.218/0.497

TP, TPD 50-190/4

DN 50

DN 50

72.4/148.9

83.8/171.6

78.8/168.1

90.6/190.2

0.193/0.470

0.218/0.497

TP, TPD 50-230/4

DN 50

DN 50

76.9/157.9

80.9/165.8

83.3/177.1

87.7/184.4

0.193/0.470

0.218/0.497

TP, TPD 65-30/4

DN 65

DN 65

33.0/56.5

37.8/62.1

35.0/59.5

41.0/65.5

0.056/0.140

0.064/0.151

TP, TPD 65-60/4

DN 65

DN 65

33.7/63.8

36.3/69.0

34.7/66.8

38.8/79.5

0.056/0.140

0.056/0.140

TP, TPD 65-90/4

DN 65

DN 65

47.1/94.9

57.3/115.3

52.1/111.4

69.4/132.6

0.125/0.346

0.184/0.391

TP, TPD 65-110/4

DN 65

DN 65

64.2/136.1

74.2/155.8

70.3/152.6

80.9/174.4

0.162/0.346

0.218/0.497

TP, TPD 65-130/4

DN 65

DN 65

66.5/140.6

75.3/158.1

72.5/157.1

82.1/176.7

0.162/0.346

0.218/0.497

TP, TPD 65-150/4

DN 65

DN 65

73.5/154.6

84.9/177.3

79.9/172.0

91.7/195.9

0.193/0.413

0.218/0.497

TP, TPD 65-170/4

DN 65

DN 65

77.8/163.2

81.8/171.1

84.2/180.6

88.6/189.7

0.193/0.413

0.218/0.497

TP, TPD 65-240/4

DN 65

DN 65

82.7/173.0

101.8/210.9

89.1/190.5

108.5/229.6

0.193/0.413

0.218/0.497

TP, TPD 80-30/4

DN 80

DN 80

37.5/68.3

41.1/72.8

39.5/71.3

44.3/76.2

0.056/0.140

0.064/0.151

TP, TPD 80-60/4

DN 80

DN 80

38.6/71.6

50.4/95.3

40.6/74.6

53.4/100.8

0.066/0.140

0.091/0.370

TP, TPD 80-70/4

DN 80

DN 80

68.0/143.0

74.1/156.2

81.0/161.0

87.1/173.2

0.218/0.391

0.218/0.497

TP, TPD 80-90/4

DN 80

DN 80

71.0/150.0

75.0/158.0

84.0/167.0

88.0/175.0

0.218/0.458

0.218/0.497

TP, TPD 80-110/4

DN 80

DN 80

76.0/159.0

84.5/176.0

89.0/176.0

98.5/206.0

0.218/0.458

0.218/0.497

TP, TPD 80-150/4

DN 80

DN 80

84.0/164.0

87.5/171.0

98.0/184.0

101.5/201.0

0.267/0.497

0.218/1.524

TP, TPD 80-170/4

DN 80

DN 80

103.0/203.0

106.3/209.6

117.0/222.0

120.3/239.6

0.267/0.497

0.218/1.524

TP, TPD 80-240/4

DN 80

DN 80

182.0/369.0

174.8/354.6

206.0/419.0

198.8/405.6

0.630/1.524

0.630/1.524

TP, TPD 80-270/4

DN 80

DN 80

193.0/391.0

265.0/536.0

217.0/441.0

290.0/586.0

0.630/1.524

0.630/1.524

TP, TPD 80-340/4

DN 80

DN 80

220.0/446.0

266.0/538.0

244.0/496.0

291.0/588.0

0.630/1.524

0.630/1.524

TP, TPD 100-30/4

DN 100

DN 100

41.0/85.0

43.0/93.0

44.0/90.0

46.2/103.0

0.140/0.213

0.151/0.220

TP, TPD 100-60/4

DN 100

DN 100

53.0/109.0

63.7/122.6

56.0/114.0

67.7/127.6

0.140/0.213

0.120/0.370

TP, TPD 100-70/4

DN 100

DN 100

96.0/193.0

100.0/201.0

110.0/210.0

114.0/251.0

0.267/0.458

0.218/0.497

TP, TPD 100-90/4

DN 100

DN 100

100.0/202.0

109.0/218.0

125.0/252.0

133.0/268.0

0.630/1.524

0.630/1.524

TP, TPD 100-110/4

DN 100

DN 100

103.0/207.0

106.5/213.0

127.0/257.0

130.5/264.0

0.630/1.524

0.630/1.524

TP, TPD 100-130/4

DN 100

DN 100

141.0/286.0

144.3/292.6

166.0/336.0

169.3/342.6

0.630/1.524

0.630/1.524

TP, TPD 100-170/4

DN 100

DN 100

156.0/316.0

149.8/301.6

180.0/366.0

183.8/352.6

0.630/1.524

0.630/1.524

TP, TPD 100-200/4

DN 100

DN 100

227.0/475.0

300.0/620.0

252.0/525.0

350.0/670.0

0.630/1.524

1.524/1.524

TP, TPD 100-250/4

DN 100

DN 100

255.0/530.0

301.0/622.0

279.0/580.0

351.0/672.0

0.630/1.524

1.524/1.524

TP, TPD 100-330/4

DN 100

DN 100

273.0/565.0

321.0/661.0

297.0/616.0

371.0/712.0

0.630/1.524

1.524/1.524

TP, TPD 100-370/4

DN 100

DN 100

302.0/623.0

355.0/729.0

344.0/674.0

405.0/780.0

0.797/1.524

1.524/1.524

TP, TPD 100-410/4

DN 100

DN 100

312.0/645.0

389.0/799.0

354.0/695.0

439.0/849.0

0.797/1.524

1.524/1.524

TP, TPD 125-110/4

DN 125

DN 125

185.0/397.0

188.3/403.6

215.0/447.0

218.3/453.6

0.653/1.524

0.653/1.524

TP, TPD 125-130/4

DN 125

DN 125

200.0/426.0

192.8/412.6

230.0/477.0

243.8/462.6

0.653/1.524

0.630/1.524

TP, TPD 125-160/4

DN 125

DN 125

210.0/447.0

283.0/592.0

240.0/498.0

333.0/643.0

0.653/1.524

1.524/1.524

TP, TPD 125-210/4

DN 125

DN 125

279.0/566.0

325.0/658.0

309.0/616.0

375.0/708.0

0.653/1.524

1.524/1.524

TP, TPD 125-250/4

DN 125

DN 125

296.0/599.0

344.0/695.0

346.0/650.0

394.0/746.0

1.524/1.524

1.524/1.524

TP, TPD 125-320/4

DN 125

DN 125

326.0/659.0

379.0/765.0

383.0/717.0

429.0/816.0

1.800/1.800

1.524/1.524

TP, TPD 125-360/4

DN 125

DN 125

336.0/681.0

413.0/835.0

394.0/738.0

464.0/885.0

1.800/1.800

1.524/1.524

Weights and shipping volume

Connection
Pump type

TP, TPD, TPE, TPED

Weights
Net [kg]

Shipping volume [m3]

Gross [kg]

D1D

D1S

TP/TPD

TPE/TPED

TP/TPD

TPE/TPED

TP/TPD

TP, TPD 125-420/4

DN 125

DN 125

435.0/878.0

492.0/935.0

1.800/1.800

TP, TPD 150-130/4

DN 150

DN 150

273.0/550.0

346.0/695.0

303.0/600.0

396.0/745.0

0.653/1.524

1.524/1.524

TP, TPD 150-160/4

DN 150

DN 150

301.0/605.0

347.0/697.0

331.0/655.0

397.0/747.0

0.653/1.524

1.524/1.524

TP, TPD 150-200/4

DN 150

DN 150

318.0/639.0

366.0/735.0

368.0/690.0

416.0/786.0

1.524/1.524

1.524/1.524

TP, TPD 150-220/4

DN 150

DN 150

347.0/697.0

400.0/803.0

404.0/755.0

450.0/854.0

1.800/1.800

1.524/1.524

TP, TPD 150-250/4

DN 150

DN 150

358.0/718.0

435.0/872.0

415.0/776.0

485.0/923.0

1.800/1.800

1.524/1.524

TP 150-310/4

DN 150

DN 200

385.0

407.0

1.28

TP 150-370/4

DN 150

DN 200

445.0

467.0

1.38

TP 200-260/4

DN 200

DN 250

500.0

522.0

1.33

TP 200-300/4

DN 200

DN 250

560.0

582.0

1.44

TP 200-390/4

DN 200

DN 250

600.0

622.0

1.44

TP 200-430/4

DN 200

DN 250

670.0

692.0

1.52

TP 250-280/4

DN 250

DN 300

690.0

755.0

1.97

TP 250-310/4

DN 250

DN 300

760.0

825.0

2.07

TP 250-390/4

DN 250

DN 300

890.0

955.0

2.10

TPE/TPED

The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

TP, TPD, 6-pole, PN 6/10/16


Connection
Pump type

Weights
Net [kg]

Shipping
volume [m3]

Gross [kg]

D1D

D1S

TP/TPD

TPE/TPED

TP/TPD

TPE/TPED

TP/TPD

TPE/TPED

TP, TPD 125-60/6

DN 125

DN 125

157.0/341.0

187.0/391.0

0.653/1.524

TP, TPD 125-70/6

DN 125

DN 125

166.0/359.0

196.0/409.0

0.653/1.524

TP, TPD 125-90/6

DN 125

DN 125

230.0/469.0

260.0/519.0

0.653/1.524

TP, TPD 125-110/6

DN 125

DN 125

237.0/482.0

267.0/533.0

0.653/1.524

TP, TPD 125-140/6

DN 125

DN 125

244.0/496.0

274.0/546.0

0.653/1.524

TP, TPD 125-170/6

DN 125

DN 125

280.0/567.0

310.0/618.0

0.653/1.524

TP, TPD 150-60/6

DN 150

DN 150

229.0/461.0

259.0/512.0

0.653/1.524

TP, TPD 150-70/6

DN 150

DN 150

253.0/508.0

283.0/558.0

0.653/1.524

TP, TPD 150-90/6

DN 150

DN 150

259.0/522.0

289.0/572.0

0.653/1.524

TP, TPD 150-110/6

DN 150

DN 150

265.0/534.0

295.0/584.0

0.653/1.524

The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

TP, 2-pole, PN 25
Connection

Weights

D1D

D1S

Net [kg]

Gross [kg]

Shipping
volume [m3]

TP 100-620/2

DN 100

DN 125

400.0

422.0

1.24

TP 100-700/2

DN 100

DN 125

475.0

497.0

1.32

TP 100-820/2

DN 100

DN 125

570.0

592.0

1.40

TP 100-960/2

DN 100

DN 125

720.0

742.0

1.42

TP 100-1050/2

DN 100

DN 125

785.0

807.0

1.14

TP 100-1180/2

DN 100

DN 125

845.0

867.0

1.46

TP 100-1400/2

DN 100

DN 125

875.0

897.0

1.51

TP 100-1530/2

DN 100

DN 125

1035.0

1100.0

1.13

TP 100-1680/2

DN 100

DN 125

1125.0

1190.0

1.21

TP 125-580/2

DN 125

DN 150

590.0

612.0

1.42

TP 125-720/2

DN 125

DN 150

740.0

762.0

1.44

TP 125-750/2

DN 125

DN 150

800.0

822.0

1.49

TP 125-1060/2

DN 125

DN 150

895.0

917.0

1.54

TP 125-1160/2

DN 125

DN 150

1055.0

1120.0

1.21

TP 125-1310/2

DN 125

DN 150

1145.0

1210.0

1.30

TP 125-1500/2

DN 125

DN 150

1245.0

1310.0

1.30

TP 125-1670/2

DN 125

DN 150

1545.0

1610.0

1.41

Pump type

117

Weights and shipping volume

TP, TPD, TPE, TPED

TP, 4-pole, PN 25

118

Connection

Weights

D1D

D1S

Net [kg]

Gross [kg]

Shipping
volume [m3]

TP 100-190/4

DN 100

DN 125

215.0

237.0

0.93

TP 100-220/4

DN 100

DN 125

225.0

247.0

0.96

TP 100-260/4

DN 100

DN 125

246.0

268.0

1.05

TP 100-270/4

DN 100

DN 125

311.0

333.0

1.05

TP 100-320/4

DN 100

DN 125

327.0

349.0

1.09

TP 100-380/4

DN 100

DN 125

355.0

377.0

1.14

TP 100-420/4

DN 100

DN 125

365.0

387.0

1.14

TP 125-150/4

DN 125

DN 150

245.0

267.0

0.99

TP 125-200/4

DN 125

DN 150

266.0

288.0

1.08

TP 125-240/4

DN 125

DN 150

282.0

304.0

1.12

TP 125-280/4

DN 125

DN 150

347.0

369.0

1.11

TP 125-310/4

DN 125

DN 150

375.0

397.0

1.17

TP 125-370/4

DN 125

DN 150

385.0

407.0

1.17

TP 125-430/4

DN 125

DN 150

475.0

497.0

1.23

TP 150-240/4

DN 150

DN 200

415.0

437.0

1.22

TP 150-270/4

DN 150

DN 200

425.0

447.0

1.22

TP 150-320/4

DN 150

DN 200

515.0

537.0

1.28

TP 150-350/4

DN 150

DN 200

575.0

597.0

1.39

TP 150-430/4

DN 150

DN 200

655.0

720.0

1.69

TP 150-530/4

DN 150

DN 200

725.0

790.0

1.78

TP 150-650/4

DN 150

DN 200

855.0

920.0

1.81

TP 200-270/4

DN 200

DN 250

480.0

545.0

1.50

TP 200-280/4

DN 200

DN 250

630.0

695.0

1.61

TP 200-380/4

DN 200

DN 250

670.0

735.0

1.61

TP 200-420/4

DN 200

DN 250

740.0

805.0

1.70

TP 200-450/4

DN 200

DN 250

800.0

865.0

2.37

TP 200-510/4

DN 200

DN 250

930.0

995.0

2.40

TP 200-560/4

DN 200

DN 250

965.0

1030.0

2.48

TP 200-620/4

DN 200

DN 250

1020.0

1085.0

2.59

TP 250-270/4

DN 250

DN 300

780.0

845.0

2.13

TP 250-320/4

DN 250

DN 300

850.0

915.0

2.25

TP 250-370/4

DN 250

DN 300

980.0

1045.0

2.27

TP 250-490/4

DN 250

DN 300

1115.0

1180.0

3.07

TP 250-540/4

DN 250

DN 300

1170.0

1235.0

3.16

TP 250-600/4

DN 250

DN 300

1410.0

1475.0

3.13

TP 250-660/4

DN 250

DN 300

1490.0

1555.0

3.13

TP 300-590/4

DN 300

DN 350

1750.0

1815.0

4.09

TP 300-670/4

DN 300

DN 350

1930.0

1995.0

4.48

TP 300-750/4

DN 300

DN 350

2130.0

2195.0

4.48

TP 400-470/4

DN 400

DN 500

3000.0

3065.0

7.08

TP 400-510/4

DN 400

DN 500

3400.0

3465.0

7.70

TP 400-540/4

DN 400

DN 500

3500.0

3565.0

7.70

TP 400-670/4

DN 400

DN 500

3700.0

3765.0

7.70

TP 400-720/4

DN 400

DN 500

4300.0

4365.0

8.14

TP 400-760/4

DN 400

DN 500

4500.0

4565.0

8.14

Pump type

Accessories

TP, TPE

Unions and valves


Cast iron pumps
A union kit consists of two cast iron union tails, two cast
iron union nuts and two EPDM gaskets..
Pump type,
union connection
TP, TPE 25 R

TP, TPE 32 R

Pressure stage

PN 10

PN 10

Size

Product
number

Rp

529921

Rp 1

529922

Rp 1

529924

Rp 1

509921

Rp 1

509922

A valve kit consists of two brass valves, two brass union


nuts and two EPDM gaskets.
Valve housing of pressure die-cast brass.
Pump type,
valve connection

Pressure stage

TP, TPE 25 R

PN 10

TP, TPE 32 R

PN 10

Size

Product
number

Rp

519805

Rp 1

519806

Rp 1

519807

Rp 1

505539

Bronze pumps
A union kit consists of two bronze union tails, two brass
union nuts, and two EPDM gaskets.
Valve housing of pressure die-cast brass.
Pump type,
union connection

Pressure stage

TP, TPE 25 R B

PN 10

TP, TPE 32 R B

PN 10

Size

Product
number

Rp

529971

Rp 1

529972

Rp 1

509971

A valve kit consists of two brass valves, two brass union


nuts and two EPDM gaskets.
Valve housing of presssure die-cast brass.
Pump type,
valve connection

Pressure stage

TP, TPE 25 R B

PN 10

TP, TPE 32 R B

PN 10

Size

Product
number

Rp

519805

Rp 1

519806

Rp 1

519807

Rp 1

505539

119

Accessories

TP, TPD, TPE, TPED

Counter flanges
Cast iron pumps
A flange kit consists of two steel flanges, two gaskets of
asbestos-free material IT 200, and the requisite number
of bolts.
Counter flange

Pump type

Pipework
connection

Product
number

Threaded

10 bar, EN 1092-2

Rp 1

539703

For welding

10 bar, EN 1092-2

32 mm,
nominal

539704

Threaded

10 bar, EN 1092-2

Rp 1

539701

For welding

10 bar, EN 1092-2

40 mm,
nominal

539702

Threaded

16 bar, EN 1092-2

Rp 1

539701

For welding

16 bar, EN 1092-2

40 mm,
nominal

539702

Threaded

10 bar, EN 1092-2

Rp 2

549801

For welding

10 bar, EN 1092-2

50 mm,
nominal

549802

Threaded

16 bar, EN 1092-2

Rp 2

549801

For welding

16 bar, EN 1092-2

50 mm,
nominal

549802

Threaded

10 bar, EN 1092-2

Rp 2

559801

For welding

10 bar, EN 1092-2

65 mm,
nominal

559802

Threaded

16 bar, EN 1092-2

Rp 2

559801

For welding

16 bar, EN 1092-2

65 mm,
nominal

559802

78
100
140

For welding

TM03 0478 5204

19

Rp 1

Threaded

Rated
pressure

Description

TP, TPE 32
TPD, TPED 32

19

Rp 1

Threaded

88
110
150

For welding

TM03 0479 5204

TP, TPE 40
TPD, TPED 40

19

Rp 2

Threaded

102
125
165

For welding

TM03 0480 5204

TP, TPE 50
TPD, TPED 50

19

Rp 2

Threaded

120

For welding

122
145
185

TM03 0481 5204

TP, TPE 65
TPD, TPED 65

Accessories

TP, TPD, TPE, TPED

Counter flange

Rp 3

Pump type

Rated
pressure

Pipework
connection

Product
number

Threaded

6 bar, EN 1092-2

Rp 3

569902

For welding

6 bar, EN 1092-2

80 mm,
nominal

569901

Threaded

10 bar, EN 1092-2

Rp 3

569802

For welding

10 bar, EN 1092-2

80 mm,
nominal

569801

Threaded

16 bar, EN 1092-2

Rp 3

569802

For welding

16 bar, EN 1092-2

80 mm,
nominal

569801

Threaded

6 bar, EN 1092-2

Rp 4

579901

For welding

6 bar, EN 1092-2

100 mm,
nominal

579902

Threaded

10 bar, EN 1092-2

Rp 4

579801

For welding

10 bar, EN 1092-2

100 mm,
nominal

579802

Threaded

16 bar, EN 1092-2

Rp 4

579801

For welding

16 bar, EN 1092-2

100 mm,
nominal

579802

Threaded

10 bar, EN 1092-2

Rp 5

485367

For welding

10 bar, EN 1092-2

125 mm,
nominal

485368

Threaded

16 bar, EN 1092-2

Rp 5

485367

For welding

16 bar, EN 1092-2

125 mm,
nominal

485368

For welding

10 bar, EN 1092-2

150 mm,
nominal

S1111600

For welding

16 bar, EN 1092-2

150 mm,
nominal

S1111600

Description

19

TP, TPE 80
TPD, TPED 80
138
160
200

For welding

TM03 0482 5204

Threaded

Rp 4

19

TP, TPE 100


TPD, TPED 100
158
180
220

For welding

TM03 0483 5204

Threaded

Rp 5

19

Threaded

188
210
250

For welding

TM03 0484 5204

TP, TPE 125


TPD, TPED 125

For welding

212
240
285

TM03 0485 5204

23

TP, TPE 150


TPD, TPED 150

121

Accessories

TP, TPD, TPE, TPED

Bronze pumps
A flange kit consists of two bronze flanges, two gaskets
of asbestos-free material IT 200, and the requisite
number of bolts.
Counter flange

Rated
pressure

Pipework
connection

Product
number

Threaded

10 bar, EN 1092-2

Rp 1

96427029

For welding

10 bar, EN 1092-2

32 mm,
nominal

96427030

Threaded

10 bar, EN 1092-2

Rp 1

539711

For welding

10 bar, EN 1092-2

40 mm,
nominal

539712

Threaded

16 bar, EN 1092-2

Rp 1

539711

For welding

16 bar, EN 1092-2

40 mm,
nominal

539712

Threaded

10 bar, EN 1092-2

Rp 2

549811

For welding

10 bar, EN 1092-2

50 mm,
nominal

549812

Threaded

10 bar, EN 1092-2

Rp 2

559811

For welding

10 bar, EN 1092-2

65 mm,
nominal

559812

Threaded

6 bar, EN 1092-2

Rp 3

96405735

For welding

6 bar, EN 1092-2

80 mm,
nominal

569911

Threaded

10 bar, EN 1092-2

Rp 3

569812

For welding

10 bar, EN 1092-2

80 mm,
nominal

569811

Description

78
100
140

For welding

TM03 0478 5204

19

Rp 1

Threaded

Pump type

TP, TPE 32 B

19

Rp 1

88
110
150

For welding

Threaded

102
125
165

For welding

TP, TPE 50 B

19

Rp 2

Threaded

TM03 0480 5204

19

Rp 2

122
145
185

For welding

Rp 3

TM03 0481 5204

Threaded

TM03 0479 5204

TP, TPE 40 B

TP, TPE 65 B

19

Threaded

122

For welding

138
160
200

TM03 0482 5204

TP, TPE 80 B

Accessories

TP, TPD, TPE, TPED

Counter flange
Rp 4

Rated
pressure

Pipework
connection

Product
number

Threaded

6 bar, EN 1092-2

Rp 4

96405737

Threaded

10 bar, EN 1092-2

Rp 4

96405738

Description

19

For welding

158
180
220

TM03 0483 5204

Threaded

Pump type

TP, TPE 100 B

123

Accessories

TP, TPD, TPE, TPED

Base plates

TP, TPE Series 300

Note: Base plates are supplied as standard with TP,


TPD, TPE, TPED pumps with 11 kW motors and above.

Pump type

TP, TPE series 100 and 200


Hexagon head screws

Product
number

TP, TPE 32
TP, TPE 40
TP, TPE 50
TP 65-60/2
TP, TPE 65-120/2
TP 65-180/2

2 x M12 x 20 mm

96405915

TP 65-30/4
TP, TPE 65-60/4
TP, TPE 80
TP, TPE 100

2 x M16 x 30 mm

96405914

Pump type

TP, TPE 80-240/4


TP, TPE 80-270/4
TP, TPE 80-340/4
TP, TPE 100-250/2
TP, TPE 100-310/2
TP, TPE 100-360/2
TP, TPE 100-390/2
TP, TPE 100-480/2
TP, TPE 100-xx/4
TP, TPE 125-xx/4
TP, TPE 150-xx/4

Product
number

Product
number

35

4x14

4x18

96405915
96405914
TM00 9835 0497

160

2x14
2x14

2x18
4x14
120
200

TP, TPE series 300


Pump type
TP, TPE 32
TP, TPE 40
TP, TPE 50
TP, TPE 65
TP, TPE 80-xx/2
TP, TPE 80-70/4
TP, TPE 80-90/4
TP, TPE 80-110/4
TP, TPE 80-150/4
TP, TPE 80-170/4
TP, TPE 100-160/2
TP, TPE 100-200/2
TP, TPE 100-240/2

Hexagon head screws

Product
number

2 x M16 x 30 mm

00485031

Product
number

Drawing
235
195

35

2x14

2x18

4x14
144

TM00 3755 2602

00485031

96536246
TM02 8869 1004

35

195
2x18

80

96536246

290

235

195

2 x M16 x 30 mm

380
290
230

Drawing

195
96

Product
number

Drawing

Except TPE 32-90.

124

Hexagon head screws

Accessories

TPD, TPED

TPD, TPED series 300


Pump type

TPD, TPED series 300


Hexagon screws

TPD, TPED 32
TPD, TPED 40
TPD, TPED 50
TPD, TPED 65
TPD, TPED 80-xx/2
TPD, TPED 80-70/4
TPD, TPED 80-90/4
TPD, TPED 80-110/4
TPD, TPED 80-150/4
TPD, TPED 80-170/4
TPD, TPED 100-160/2
TPD, TPED 100-200/2
TPD, TPED 100-240/2

4 x M16 x 30 mm

Product
number

96489381

Pump type

Hexagon screws

Product
number

TPD, TPED 80-240/4


TPD, TPED 80-270/4
TPD, TPED 80-340/4
TPD, TPED 100-200/4
TPD, TPED 100-250/4
TPD, TPED 100-330/4
TPD, TPED 100-370/4
TPD, TPED 100-410/4
TPD, TPED 125-xx/4
TPD, TPED 150-xx/4

4 x M16 x 30 mm

96536248

Product
number

Drawing
Product
number

2x14

TM02 5336 2602

67

47
300
330

475
505

2x14

TM02 8871 1004

96489381

2x18

175

96536248

4x18
47

350
300

67

35

35

Drawing

TPD, TPED series 300


Pump type

Hexagon screws

Product
number

TPD, TPED 100-250/2


TPD, TPED 100-310/2
TPD, TPED 100-360/2
TPD, TPED 100-390/2
TPD, TPED 100-70/4
TPD, TPED 100-90/4
TPD, TPED 100-110/4
TPD, TPED 100-130/4
TPD, TPED 100-170/4

4 x M16 x 30 mm

96536247

Product
number

35

Drawing

96536247

355
385

2x14

TM02 8870 1004

47

2x18

67

230

125

Accessories

TPD, TPED

Blanking flanges

TM00 6360 3495

Normally used with twin-head pumps.

TPD, TPED 2-pole


Pump type

00545048

TPD, TPED 32-60/2

TPD, TPED 32-120/2

00565055

TPD, TPED 32-150/2

TPD, TPED 32-180/2

TPD, TPED 32-230/2

96495694

TPD, TPED 32-200/2

TPD, TPED 32-250/2

TPD, TPED 32-320/2

TPD, TPED 32-380/2

z
z

TPD, TPED 32-580/2


TPD, TPED 40-60/2

TPD, TPED 40-120/2

TPD, TPED 40-190/2

TPD, TPED 40-230/2

TPD, TPED 40-270/2

TPD, TPED 40-240/2

TPD, TPED 40-300/2

TPD, TPED 40-360/2

z
z

TPD, TPED 40-470/2

TPD, TPED 40-580/2


z

TPD, TPED 50-120/2

TPD, TPED 50-180/2

TPD, TPED 50-160/2

TPD, TPED 50-190/2

TPD, TPED 50-240/2

TPD, TPED 50-290/2

TPD, TPED 50-360/2

TPD, TPED 50-430/2

TPD, TPED 50-440/2

TPD, TPED 50-570/2

TPD, TPED 50-710/2

TPD, TPED 50-830/2

z
z

TPD, TPED 50-900/2


TPD, TPED 65-60/2

126

96495696

TPD, TPED 32-460/2

TPD, TPED 50-60/2

96495695

TPD, TPED 65-120/2

TP, TPD 65-180/2

TPD, TPED 65-190/2

TPD, TPED 65-230/2

96525962

96525963

96525964

Accessories

Pump type

00545048

TPD, TPED

00565055

96495694

TPD, TPED 65-260/2

TPD, TPED 65-340/2

TPD, TPED 65-410/2

TPD, TPED 65-340/2

TPD, TPED 65-410/2

96495695

96495696

TPD, TPED 65-460/2

TPD, TPED 65-550/2

TPD, TPED 65-660/2

TPD, TPED 65-720/2

TPD, TPED 80-180/2

TPD, TPED 80-210/2

TPD, TPED 80-240/2

TPD, TPED 80-250/2

TPD, TPED 80-330/2

TPD, TPED 80-400/2

TPD, TPED 80-520/2

TPD, TPED 80-570/2

z
z

TP, TPD 80-700/2


z

TPD, TPED 100-160/2

TPD, TPED 100-200/2

TPD, TPED 100-240/2

TPD, TPED 100-250/2

TPD, TPED 100-310/2

TPD, TPED 100-360/2

TPD, TPED 100-390/2

TP, TPD 100-480/2

96525964

TPD, TPED 80-140/2

TPD, TPED 100-120/2

96525963

TPD 65-930/2
TPD, TPED 80-120/2

96525962

127

Accessories

TPE, TPED

TPD, TPED 4-pole


Pump type

00545048

TPD, TPED 32-30/4

TPD, TPED 32-40/4

00565055

96495694

TPD, TPED 32-80/4

TPD, TPED 32-100/4

96525963

z
z

TPD, TPED 40-100/4

TPD, TPED 40-130/4

TPD, TPED 40-160/4


z
z
z

TPD, TPED 50-90/4


TPD, TPED 50-110/4

TPD, TPED 50-130/4

TPD, TPED 50-160/4

TPD, TPED 50-190/4

z
z

TPD, TPED 50-230/4


TPD, TPED 65-30/4

TPD, TPED 65-60/4

z
z

TPD, TPED 65-90/4


TPD, TPED 65-110/4

TPD, TPED 65-130/4

TPD, TPED 65-150/4

TPD, TPED 65-170/4

z
z

TPD, TPED 65-240/4


TPD, TPED 80-30/4

TPD, TPED 80-60/4

TPD, TPED 80-70/4

TPD, TPED 80-90/4

TPD, TPED 80-110/4

TPD, TPED 80-150/4

TPD, TPED 80-170/4

TPD, TPED 80-240/4

TPD, TPED 80-270/4

z
z

TPD, TPED 80-340/4


TPD, TPED 100-30/4

TPD, TPED 100-60/4

TPD, TPED 100-70/4

TPD, TPED 100-90/4

TPD, TPED 100-110/4

TPD, TPED 100-130/4

TPD, TPED 100-170/4

TPD, TPED 100-200/4

TPD, TPED 100-250/4

TPD, TPED 100-330/4

TPD, TPED 100-370/4

z
z

TPD, TPED 100-410/4


TPD, TPED 125-110/4

TPD, TPED 125-130/4

TPD, TPED 125-160/4

TPD, TPED 125-210/4

TPD, TPED 125-250/4

TPD, TPED 125-320/4

TPD, TPED 125-360/4

z
z

TPD 125-420/4

128

96525964

TPD, TPED 40-90/4

TPD, TPED 50-60/4

96525962

TPD, TPED 32-120/4

TPD, TPED 50-30/4

96495696

TPD, TPED 32-60/4

TPD, TPED 40-30/4

96495695

TPD, TPED 150-130/4

TPD, TPED 150-160/4

Accessories

Pump type

00545048

TPE, TPED

00565055

96495694

96495695

96495696

96525962

96525963

TPD, TPED 150-200/4

TPD, TPED 150-220/4

TPD, TPED 150-250/4

96525964

TPD 6-pole
Pump type

00545048

00565055

96495694

96495695

96495696

96525962

TP, TPD 125-60/6

TP, TPD 125-70/6

96525963

96525964

TP, TPD 125-90/6

TP, TPD 125-110/6

TP, TPD 125-140/6

z
z

TP, TPD 125-170/6


TP, TPD 150-60/6

TP, TPD 150-70/6

TP, TPD 150-90/6

TPD 150-110/6

129

Accessories

TPE Series 200

Insulating kits

Product numbers of insulating kits

Insulating kits are only available for TP, TPE Series 200
pumps. An insulating kit consists of two or three insulating covers made of expanded polypropylene (EPP).

Product number
96405871

TP, TPE 32-40/4

96405880

The insulating kit is tailored to the individual pump


model and has an insulating thickness corresponding to
the nominal diameter of the pump.

TP, TPE 32-60/2

96405873

TP, TPE 32-60/4

96405880

TP, TPE 32-120/2

96405873

The thermal conductivity of EPP is very low (0.04 W/


mC), i.e. the insulating property is very good.

TP, TPE 32-150/2

96405880

TP, TPE 32-180/2

96405880

TP, TPE 32-230/2

96405880

The insulating kit encloses the entire pump housing.

TP, TPE 40-30/4

96405874

TP, TPE 40-60/4

96405875

TP, TPE 40-60/2

96405876

TP, TPE 40-90/4

96405880

TP, TPE 40-120/2

96405877

TP, TPE 40-180/2

96405878

TP, TPE 40-190/2

96405880

TP, TPE 40-230/2

96405880

TM00 8095 2496

TP, TPE 32-30/4

Fig. 30 Insulating kit

130

Single-head TP, TPE Series 200 pumps


Pump type

TP, TPE 40-270/2

96405880

TP, TPE 50-30/4

96405879

TP, TPE 50-60/2

96405881

TP, TPE 50-60/4

96405880

TP, TPE 50-120/2

96405882

TP, TPE 50-180/2

96405883

TP, TPE 65-30/4

96405884

TP, TPE 65-60/2

96405886

TP, TPE 65-60/4

96405885

TP, TPE 65-120/2

96405887

TP, TPE 65-180/2

96405888

TP, TPE 80-30/4

96405889

TP, TPE 80-60/4

96405890

TP, TPE 80-120/2

96405891

TP, TPE 100-30/4

96405892

TP, TPE 100-60/4

96405892

TP, TPE 100-120/2

96408407

Accessories

TPE, TPED

Sensors
Accessory

Type

Flowmeter

SITRANS F M MAGFLO
MAG 5100 W

Flowmeter

SITRANS F M MAGFLO
MAG 5100 W

Flowmeter
Flowmeter

SITRANS F M MAGFLO
MAG 5100 W
SITRANS F M MAGFLO
MAG 5100 W

Supplier

Measuring range

Product number

Siemens

1 - 5 m3/h
(DN 25)

ID8285

Siemens

3 - 10 m3/h
(DN 40)

ID8286

6 - 30 m /h
(DN 65)

Siemens

ID8287

20 - 75 m /h
(DN 100)

Siemens

ID8288

Temperature sensor

TTA (0) 25

Carlo Gavazzi

0C to +25C

96432591

Temperature sensor

TTA (-25) 25

Carlo Gavazzi

25C to +25C

96430194

Temperature sensor

TTA (50) 100

Carlo Gavazzi

50C to +100C

96432592

Temperature sensor

TTA (0) 150

Carlo Gavazzi

0C to +150C

96430195

Protecting tube
9 x 50 mm

Carlo Gavazzi

96430201

Protecting tube
9 x 100 mm

Carlo Gavazzi

96430202
96430203

Accessory for temperature sensor.


All with RG connection.

Cutting ring bush

Carlo Gavazzi

Temperature sensor,
ambient temperature

WR 52

tmg
(DK: Plesner)

50C to +50C

ID8295

Differential temperature sensor

ETSD

Honsberg

0C to +20C

96409362

Differential temperature sensor

ETSD

Honsberg

0C to +50C

96409363

Note: All sensors have 4-20 mA output signal.

Sensors for boosting applications


Danfoss pressure sensor kit

Connection: G A
(DIN 16288 - B6kt)
Electrical connection: plug
(DIN 43650)

Pressure sensor type MBS 3000,


with 2 m screened cable
Connection: G A (DIN 16288 - B6kt)
5 cable clips (black)
Fitting instructions PT (00400212)

Pressure range

Product number

0 - 2.5 bar

96478188

0 - 4 bar

91072075

0 - 6 bar

91072076

0 - 10 bar

91072077

0 - 16 bar

91072078

0 - 2.5 bar

405159

0 - 4 bar

405160

0 - 6 bar

405161

0 - 10 bar

405162

0 - 16 bar

405163

Pressure range

Product number

0 - 0.6 bar

485450

0 - 1 bar

485441

0 - 1.6 bar

485442

0 - 2.5 bar

485443

0 - 4 bar

485444

0 - 6 bar

485445

0 - 10 bar

96440089

Sensors for circulation applications


HUBA differential pressure sensor kit

1
1
1
2
1
1
2
2
5

sensor incl. 1.5 m screened cable (7/16" connections)


original HUBA bracket (for wall mounting)
Grundfos bracket (for mounting on motor)
M4 screws for mounting of sensor on bracket
M6 screw (self-cutting) for mounting on MGE 90/100
M8 screw (self-cutting) for mounting on MGE 112/132
capillary tubes (short/long)
bracket (1/4" - 7/16")
cable clips (black)

Select a differential pressure sensor whose maximum pressure is higher than the maximum differential pressure of the
pump.

131

Accessories

TPE, TPED

Potentiometer
Potentiometer for setpoint setting and start/stop of the
pump.
Product
External potentiometer with cabinet for wall
mounting.

Product number
625468

R100
R100 is used for wireless communication. Ccommunication takes place by means of infrared light.
Product
R100

Product number
625333

G10-LON interface
The G10-LON interface is used in connection with data
transmission between a Locally Operating Network
(LON) and electronically controlled Grundfos pumps
applying the Grundfos bus-protocol GENIbus.
Product
G10-LON interface

Product number
00605726

EMC-filter
EMC-filter is required for installation of pumps of 5.5 kW
and higher in residential areas.
Product

132

Product number

EMC-filter (5.5 kW, 4 pole and 7.5 kW, 2 pole)

96041047

EMC-filter (7.5, 4-pole to 22 kW)

96478309

Minimum inlet pressure - NPSH

Temp.
[C]

A minimum inlet pressure is required to avoid pressure


drop that may cause cavitation.
The minimum inlet pressure (Ps) in bar can be calculated using the following formula.
Note: Calculation of the minimum inlet pressure should
be based on the maximum required flow.

Ps

NPSH

1
2
p s ( NPSH R + H s ) g --- c p b + p d
2

Ps

= Minimum inlet pressure in bar.

NPSHR = The requured Net Positive Suction Head


in metres head.
(To be read from the NPSH curve at the
highest flow the pump will be delivering).
= Safety margin = minimum 0.5 metres
Hs
head.
Note: A safety margin of 0.5 metres prevents pressure drop.
r
= Density of the pumped liquid measured
in kg/m3.
g
= Gravitational acceleration measured in
m/s. For estimated calculations use the
value 9.81 m/s2.
c
= Flow velocity of the pumped liquid at the
pressure gauge. Insert the flow velocity
as the unit [m/s].
(See individual curve charts from
page 46).
= Barometric pressure in bar.
pb
(Set the barometric pressure to 0.97 bar)
Note: Only occassionally is the pressure
as high as 1 bar; also this value is at sea
level.
= Vapour pressure in bar.
Pd
(See Fig. 31 on page 133).

Pd
[bar]

150

4.76

140

3.61

130

2.70

120

1.99

110

1.43

100

1.01

90

0.70

80

0.47

70

0.31

60

0.20

50

0.12

40

0.07

30

0.04

20

0.02

10

0.01

TM02 8491 0204 - TM03 0371 5004

To ensure optimum and noiseless operation we recommend the minimum inlet pressure values shown on
page 134 to 136.

TP, TPD

Fig. 31 Minimum inlet pressure

133

Minimum inlet pressure - NPSH

TP, TPD 2-pole, PN 6/10/16


Pump type

134

Pump type

p [bar]
20C

60C

90C

110C

120C

140C

TP 25-50/2 R

0.1

0.1

0.1

0.8

1.4

3.1

TP 25-90/2 R

0.1

0.1

0.1

0.8

1.4

3.1

TP 32-50/2 R

0.1

0.1

0.1

0.8

1.4

3.1

TP 32-90/2 R

0.1

0.1

0.1

0.8

1.4

3.1

TP, TPD 32-60/2

0.1

0.1

0.2

1.0

1.5

3.2

TP, TPD 32-120/2

0.1

0.2

0.7

1.5

2.0

3.7

TP, TPD 32-150/2

0.1

0.3

0.8

1.6

2.1

3.8

TP, TPD 32-180/2

0.5

0.7

1.2

2.0

2.5

4.2

TP, TPD 32-230/2

0.7

0.9

1.4

2.2

2.7

4.4

TP, TPD 32-200/2

0.1

0.1

0.2

0.9

1.5

3.1

TP, TPD 32-250/2

0.1

0.1

0.3

1.0

1.6

3.2

TP, TPD 32-320/2

0.1

0.1

0.6

1.3

1.9

3.5

TP, TPD 32-380/2

0.1

0.2

0.7

1.4

2.0

3.6

TP, TPD 32-460/2

0.1

0.2

0.7

1.4

1.9

3.6

TP, TPD 32-580/2

0.2

0.4

0.9

1.6

2.2

3.8

TP 40-50/2

0.1

0.1

0.1

0.8

1.4

3.1

TP, TPD 40-60/2

0.1

0.1

0.5

1.2

1.8

3.5

TP 40-90/2

0.1

0.1

0.1

0.8

1.4

3.1

TP, TPD 40-120/2

0.1

0.1

0.4

1.2

1.7

3.4

TP 40-180/2

0.1

0.2

0.7

1.5

2.0

3.7

TP, TPD 40-190/2

0.1

0.3

0.8

1.6

2.1

3.8

TP, TPD 40-230/2

0.7

0.9

1.4

2.2

2.7

4.4

TP, TPD 40-270/2

0.7

0.9

1.4

2.2

2.7

4.4

TP, TPD 40-240/2

0.1

0.1

0.4

1.1

1.7

3.3

TP, TPD 40-300/2

0.1

0.1

0.4

1.1

1.6

3.3

TP, TPD 40-360/2

0.2

0.4

0.9

1.6

2.1

3.8

TP, TPD 40-470/2

0.1

0.1

0.4

1.1

1.6

3.3

TP, TPD 40-580/2

0.2

0.4

0.9

1.6

2.1

3.8

TP, TPD 50-60/2

0.1

0.1

0.4

1.1

1.7

3.4

TP, TPD 50-120/2

0.1

0.2

0.7

1.5

2.0

3.7

TP, TPD 50-180/2

0.1

0.2

0.7

1.4

2.0

3.7

TP, TPD 50-160/2

0.1

0.1

0.1

0.8

1.4

3.0

TP, TPD 50-190/2

0.1

0.1

0.1

0.9

1.4

3.0

TP, TPD 50-240/2

0.1

0.1

0.1

0.8

1.4

3.0

TP, TPD 50-290/2

0.1

0.1

0.2

0.9

1.5

3.1

TP, TPD 50-360/2

0.1

0.1

0.2

1.0

1.5

3.1

TP, TPD 50-430/2

0.1

0.1

0.4

1.1

1.6

3.2

TP, TPD 50-440/2

0.1

0.1

0.4

1.1

1.6

3.3

TP, TPD 50-570/2

0.1

0.3

0.8

1.6

2.1

3.7

TP, TPD 50-710/2

0.6

0.8

1.3

2.0

2.6

4.2

TP, TPD 50-830/2

0.5

0.7

1.2

2.0

2.5

4.1

TP, TPD 50-900/2

1.0

1.2

1.7

2.4

3.0

4.6

TP, TPD 65-60/2

0.1

0.3

0.8

1.5

2.1

3.8

TP, TPD 65-120/2

0.5

0.7

1.2

2.0

2.5

4.2

TP, TPD 65-180/2

0.3

0.5

1.0

1.8

2.3

4.0

TP, TPD 65-190/2

0.1

0.1

0.1

0.7

1.3

2.9

TP, TPD 65-230/2

0.1

0.1

0.1

0.8

1.4

3.0

TP, TPD 65-260/2

0.1

0.1

0.1

0.8

1.4

3.0

TP, TPD 65-340/2

0.1

0.1

0.2

0.9

1.4

3.1

TP, TPD 65-410/2

0.1

0.1

0.2

0.9

1.4

3.1

TP, TPD 65-460/2

0.1

0.1

0.2

1.0

1.5

3.1

TP, TPD 65-550/2

0.1

0.1

0.3

1.0

1.6

3.2

TP, TPD 65-660/2

0.1

0.1

0.4

1.1

1.6

3.3

TP, TPD 65-720/2

0.1

0.1

0.6

1.3

1.9

3.5

TP, TPD 65-930/2

0.6

0.8

1.3

2.0

2.6

4.2

TP, TPD 80-120/2

1.2

1.4

1.9

2.7

3.2

4.9

TP, TPD 80-140/2

0.1

0.2

0.7

1.4

1.9

3.6

TP, TPD 80-180/2

0.1

0.1

0.3

1.1

1.6

3.2

TP, TPD

p [bar]
20C

60C

90C

110C

120C

140C

TP, TPD 80-210/2

0.1

0.1

0.4

1.1

1.7

3.3

TP, TPD 80-240/2

0.1

0.1

0.6

1.3

1.8

3.5

TP, TPD 80-250/2

0.1

0.3

0.8

1.6

2.1

3.7

TP, TPD 80-330/2

0.1

0.2

0.7

1.4

2.0

3.6

TP, TPD 80-400/2

0.2

0.4

0.9

1.7

2.2

3.8

TP, TPD 80-520/2

0.1

0.2

0.7

1.4

1.9

3.6

TP, TPD 80-570/2

0.1

0.3

0.8

1.6

2.1

3.7

TP, TPD 80-700/2

0.6

0.8

1.3

2.1

2.6

4.2

TP, TPD 100-120/2

1.9

2.1

2.6

3.4

3.9

5.6

TP, TPD 100-160/2

0.1

0.1

0.6

1.3

1.9

3.5

TP, TPD 100-200/2

0.1

0.1

0.4

1.2

1.7

3.3

TP, TPD 100-240/2

0.1

0.1

0.5

1.3

1.8

3.4

TP, TPD 100-250/2

0.6

0.8

1.3

2.0

2.5

4.2

TP, TPD 100-310/2

0.6

0.8

1.3

2.0

2.6

4.2

TP, TPD 100-360/2

0.6

0.8

1.3

2.0

2.6

4.2

TP, TPD 100-390/2

1.0

1.2

1.7

2.4

3.0

4.6

TP, TPD 100-480/2

1.5

1.7

2.2

2.9

3.5

5.1

Minimum inlet pressure - NPSH

TP, TPD 4-pole, PN 6/10/16


Pump type

Pump type

p [bar]
20C

60C

90C

110C

120C

140C

TP, TPD 32-30/4

0.1

0.1

0.1

0.8

1.4

3.1

TP, TPD 32-40/4

0.1

0.1

0.1

0.9

1.4

3.1

TP, TPD 32-60/4

0.1

0.1

0.3

1.1

1.6

3.3

TP, TPD 32-80/4

0.1

0.1

0.1

0.5

1.1

2.7

TP, TPD 32-100/4

0.1

0.1

0.1

0.5

1.1

2.7

TP, TPD 32-120/4

0.1

0.1

0.1

0.6

1.1

2.7

TP, TPD 40-30/4

0.1

0.1

0.2

0.9

1.5

3.2

TP 40-60/4

0.1

0.1

0.1

0.8

1.4

3.1

TP, TPD 40-90/4

0.1

0.1

0.3

1.0

1.6

3.3

TP, TPD 40-100/4

0.1

0.1

0.2

0.9

1.5

3.1

TP, TPD 40-130/4

0.1

0.1

0.1

0.7

1.2

2.8

TP, TPD 40-160/4

0.1

0.1

0.2

0.9

1.5

3.1

TP, TPD 50-30/4

0.1

0.1

0.1

0.9

1.4

3.1

TP, TPD 50-60/4

0.1

0.1

0.2

0.9

1.5

3.2

TP, TPD 50-90/4

0.1

0.1

0.1

0.6

1.4

2.8

TP, TPD 50-110/4

0.1

0.1

0.1

0.6

1.4

2.8

TP, TPD 50-130/4

0.1

0.1

0.1

0.6

1.2

2.8

TP, TPD 50-160/4

0.1

0.1

0.1

0.7

1.3

2.9

TP, TPD 50-190/4

0.1

0.1

0.1

0.9

1.4

TP, TPD 50-230/4

0.1

0.1

0.1

1.0

TP, TPD 65-30/4

0.1

0.2

0.7

TP, TPD 65-60/4

0.2

0.4

0.9

TP, TPD

p [bar]
20C

60C

90C

110C

120C

140C

TP, TPD 150-130/4

0.1

0.1

0.4

1.1

1.6

3.3

TP, TPD 150-160/4

0.1

0.1

0.4

1.1

1.7

3.3

TP, TPD 150-200/4

0.1

0.1

0.4

1.1

1.7

3.3

TP, TPD 150-220/4

0.1

0.1

0.5

1.2

1.8

3.4

TP, TPD 150-250/4

0.1

0.1

0.6

1.3

1.9

3.5

TP 150-310/4

0.1

0.1

0.2

0.9

1.5

3.1

TP 150-370/4

0.1

0.1

0.2

0.9

1.4

3.1

TP 200-260/4

0.1

0.1

0.1

0.8

1.4

3.1

TP 200-300/4

0.1

0.1

0.1

0.8

1.4

3.1

TP 200-390/4

0.1

0.1

0.1

0.8

1.4

3.1

TP 200-430/4

0.1

0.1

0.1

0.8

1.4

3.1

TP 250-280/4

0.1

0.1

0.1

0.8

1.4

3.1

TP 250-310/4

0.1

0.1

0.1

0.8

1.4

3.1

TP 250-390/4

0.1

0.1

0.1

0.8

1.4

3.1

TP, TPD 6-pole, PN 16


Pump type

p [bar]
20C

60C

90C

110C

120C

140C

TP, TPD 125-60/6

0.1

0.1

0.1

0.7

1.2

2.8

3.0

TP, TPD 125-70/6

0.1

0.1

0.1

0.7

1.3

2.9

1.5

3.2

TP, TPD 125-90/6

0.1

0.1

0.1

0.7

1.2

2.9

1.5

2.0

3.7

TP, TPD 125-110/6

0.1

0.1

0.1

0.8

1.3

2.9

1.6

2.2

3.9

TP, TPD 125-140/6

0.1

0.1

0.1

0.7

1.3

2.9

TP, TPD 65-90/4

0.1

0.1

0.1

0.6

1.1

2.7

TP, TPD 125-170/6

0.1

0.1

0.1

0.8

1.4

3.0

TP, TPD 65-110/4

0.1

0.1

0.1

0.6

1.1

2.7

TP, TPD 150-60/6

0.1

0.1

0.1

0.7

1.3

2.9

TP, TPD 65-130/4

0.1

0.1

0.1

0.6

1.1

2.8

TP, TPD 150-70/6

0.1

0.1

0.1

0.7

1.3

2.9

TP, TPD 65-150/4

0.1

0.1

0.1

0.6

1.2

2.8

TP, TPD 150-90/6

0.1

0.1

0.1

0.8

1.3

2.9

TP, TPD 65-170/4

0.1

0.1

0.1

0.6

1.2

2.8

TP, TPD 150-110/6

0.1

0.1

0.1

0.8

1.3

3.0

TP, TPD 65-240/4

0.1

0.1

0.1

0.8

1.3

2.9

TP, TPD 80-30/4

0.8

1.0

1.5

2.2

2.8

4.5

TP, TPD 80-60/4

0.8

1.0

1.5

2.3

2.8

4.5

TP, TPD 80-70/4

0.1

0.1

0.1

0.8

1.3

2.9

TP, TPD 80-90/4

0.1

0.1

0.1

0.7

1.2

2.8

TP, TPD 80-110/4

0.1

0.1

0.1

0.8

1.4

3.0

TP, TPD 80-150/4

0.1

0.1

0.1

0.8

1.3

3.0

TP, TPD 80-170/4

0.1

0.1

0.2

1.0

1.5

3.1

TP, TPD 80-240/4

0.1

0.1

0.3

1.0

1.5

3.2

TP, TPD 80-270/4

0.1

0.1

0.2

0.9

1.5

3.1

TP, TPD 80-340/4

0.1

0.1

0.3

1.1

1.6

3.2

TP, TPD 100-30/4

0.8

1.0

1.5

2.2

2.8

4.5

TP, TPD 100-60/4

0.6

0.8

1.3

2.0

2.6

4.3

TP, TPD 100-70/4

0.1

0.1

0.1

0.8

1.3

3.0

TP, TPD 100-90/4

0.1

0.1

0.1

0.9

1.4

3.0

TP, TPD 100-110/4

0.1

0.1

0.2

1.0

1.5

3.1

TP, TPD 100-130/4

0.1

0.1

0.6

1.3

1.9

3.5

TP, TPD 100-170/4

0.3

0.5

1.0

1.7

2.3

3.9

TP, TPD 100-200/4

0.1

0.1

0.5

1.2

1.8

3.4

TP, TPD 100-250/4

0.1

0.2

0.7

1.4

2.0

3.6

TP, TPD 100-330/4

0.3

0.5

1.0

1.7

2.3

3.9

TP, TPD 100-370/4

0.3

0.5

1.0

1.7

2.3

3.9

TP, TPD 100-410/4

0.5

0.7

1.2

1.9

2.5

4.1

TP, TPD 125-110/4

0.1

0.1

0.1

0.9

1.4

3.0

TP, TPD 125-130/4

0.1

0.1

0.2

0.9

1.5

3.1

TP, TPD 125-160/4

0.1

0.1

0.3

1.0

1.5

3.2

TP, TPD 125-210/4

0.1

0.1

0.3

1.0

1.6

3.2

TP, TPD 125-250/4

0.1

0.1

0.4

1.1

1.7

3.3

TP, TPD 125-320/4

0.1

0.1

0.3

1.0

1.6

3.2

TP, TPD 125-360/4

0.1

0.1

0.4

1.2

1.7

3.3

TP, TPD 125-420/4

0.1

0.2

0.7

1.4

2.0

3.6

135

Minimum inlet pressure - NPSH

TP Series 400, 2-pole, PN 25


Pump type

136

TP

TP Series 400, 4-pole, PN 25

p [bar]
20C

60C

90C

110C

120C

140C

TP 100-620/2

0.2

0.4

0.9

1.6

2.2

3.9

TP 100-700/2

0.1

0.2

0.7

1.5

2.0

TP 100-820/2

0.1

0.2

0.7

1.4

TP 100-960/2

0.1

0.2

0.7

TP 100-1050/2

0.1

0.1

TP 100-1180/2

0.1

TP 100-1400/2

Pump type

p [bar]
20C

60C

90C

110C

120C

140C

TP 100-190/4

0.1

0.1

0.1

0.8

1.4

3.1

3.7

TP 100-220/4

0.1

0.1

0.1

0.8

1.4

3.1

2.0

3.7

TP 100-260/4

0.1

0.1

0.1

0.8

1.4

3.1

1.4

2.0

3.7

TP 100-270/4

0.1

0.1

0.1

0.8

1.4

3.1

0.6

1.3

1.9

3.6

TP 100-320/4

0.1

0.1

0.1

0.8

1.4

3.1

0.2

0.7

1.5

2.0

3.7

TP 100-380/4

0.1

0.1

0.1

0.8

1.4

3.1

0.1

0.2

0.7

1.5

2.0

3.7

TP 100-420/4

0.1

0.1

0.1

0.8

1.4

3.1

TP 100-1530/2

0.1

0.2

0.7

1.4

2.0

3.7

TP 125-150/4

0.1

0.1

0.1

0.8

1.4

3.1

TP 100-1680/2

0.1

0.1

0.6

1.4

1.9

3.6

TP 125-200/4

0.1

0.1

0.1

0.8

1.4

3.1

TP 125-580/2

0.1

0.1

0.1

0.8

1.4

3.1

TP 125-240/4

0.1

0.1

0.1

0.8

1.4

3.1

TP 125-720/2

0.1

0.1

0.1

0.8

1.4

3.1

TP 125-280/4

0.1

0.1

0.1

0.8

1.4

3.1

TP 125-750/2

0.1

0.1

0.1

0.8

1.4

3.1

TP 125-310/4

0.1

0.1

0.1

0.8

1.4

3.1

TP 125-1060/2

1.6

1.8

2.3

3.1

3.6

5.3

TP 125-370/4

0.1

0.1

0.1

0.8

1.4

3.1

TP 125-1160/2

1.6

1.8

2.3

3.0

3.6

5.3

TP 125-430/4

0.1

0.1

0.1

0.8

1.4

3.1

TP 125-1310/2

1.6

1.8

2.3

3.0

3.6

5.3

TP 150-240/4

0.1

0.1

0.1

0.8

1.4

3.1

TP 125-1500/2

1.5

1.7

2.2

3.0

3.5

5.2

TP 150-270/4

0.1

0.1

0.1

0.8

1.4

3.1

TP 125-1670/2

1.5

1.7

2.2

2.9

3.5

5.2

TP 150-320/4

0.1

0.1

0.1

0.8

1.4

3.1

TP 150-350/4

0.1

0.1

0.1

0.8

1.4

3.1

TP 150-430/4

0.1

0.1

0.1

0.8

1.4

3.1

TP 150-530/4

0.1

0.1

0.1

0.8

1.4

3.1

TP 150-650/4

0.1

0.1

0.1

0.8

1.4

3.1

TP 200-270/4

0.1

0.1

0.1

0.8

1.4

3.1

TP 200-280/4

0.1

0.1

0.1

0.8

1.4

3.1

TP 200-380/4

0.1

0.1

0.1

0.8

1.4

3.1

TP 200-420/4

0.1

0.1

0.1

0.8

1.4

3.1

TP 200-450/4

0.1

0.1

0.1

0.8

1.4

3.1

TP 200-510/4

0.1

0.1

0.1

0.8

1.4

3.1

TP 200-560/4

0.1

0.1

0.1

0.8

1.4

3.1

TP 200-620/4

0.1

0.1

0.1

0.8

1.4

3.1

TP 250-270/4

0.1

0.1

0.1

0.8

1.4

3.1

TP 250-320/4

0.1

0.1

0.1

0.8

1.4

3.1

TP 250-370/4

0.1

0.1

0.1

0.8

1.4

3.1

TP 250-490/4

0.1

0.1

0.1

0.8

1.4

3.1

TP 250-540/4

0.1

0.1

0.1

0.8

1.4

3.1

TP 250-600/4

0.1

0.1

0.1

0.8

1.4

3.1

TP 250-660/4

0.1

0.1

0.1

0.8

1.4

3.1

TP 300-590/4

0.4

0.6

1.1

1.8

2.4

4.1

TP 300-670/4

0.4

0.6

1.1

1.8

2.4

4.1

TP 300-750/4

0.3

0.5

1.0

1.8

2.3

4.0

TP 400-470/4

0.1

0.3

0.8

1.6

2.1

3.8

TP 400-510/4

0.1

0.3

0.8

1.6

2.1

3.8

TP 400-540/4

0.1

0.3

0.8

1.5

2.1

3.8

TP 400-670/4

0.6

0.8

1.3

2.1

2.6

4.3

TP 400-720/4

0.6

0.8

1.3

2.1

2.6

4.3

TP 400-760/4

0.6

0.8

1.3

2.0

2.6

4.3

Replacement list

TP, TPD

Replacement of LM, LP and


CLM pumps
The following tables give suggestions on the replacement of LM and LP pumps with new TP pumps. If
possible, replace LP pumps with 2-pole TP pumps and
LM pumps with 4-pole TP pumps.
The tables list the TP pumps recommended in order of
priority. The first TP pump listed is hydraulically the
best replacement for the LM, LP pump without considering the flange size. The next pumps in the list may be
equally suitable, as the flange size, port-to-port length
etc. may fit better.
If the port-to-port length of the TP pump is shorter than
that of the LM, LP pump, we recommend replacement
kits. A replacement kit consists of two pipe stubs with
welded-on flanges or with great plate thickness. All
replacement kits include gaskets, bolts etc.
Product
number

Same pipe dimension for new /replaced pump

TM02 8254 4703

96497637
96497639
96497641
96497643
96097993
96097994
96097995
96545597
96545605
96545607
96545610

TM02 8253 4703

Different flange dimension for new/replaced pump

Product
number

96497645
96497647
96497649
96497650
96097992
96545611

137

Replacement list

TP, TPD

Replacement of LM 40-125/142
Type
LM 40-125/142

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

40

16

0.25

390

H
[m]

TP
replacement
TP 40-90/4

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

40

16

0.18

320

50 Hz

TP 40-90/4

Flange size
DN

LM 40-125/142

LM =
TP =

/142

5
4

Replacement kit
Type
TP 40-90/4

Product number

96497637

8 Q [m/h]

TM02 7887 1104

Replacement of LM 40-160/150
Type
LM 40-160/150

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

40

16

0.25

390

H
[m]

LM 40-160/150

LM =
TP 32-80/4 TP =

8
7

50 Hz

TP 40-90/4

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

TP 32-80/4

32

16

0.25

340

TP 40-90/4

40

16

0.18

320

TP
replacement

/150

Replacement kit
Type

Product number

TP 32-80/4

Not available

TP 40-90/4

96497637

1
0

Q [m/h]

TM02 7888 1104

Replacement of LM 40-160/165

LM 40-160/165

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

40

16

0.37

390

H
[m]
10

Flange size
DN

Pressure
stage
PN

P2
[kW]

LM 40-160/165
50 Hz

9
8

TP
replacement

LM =
TP =

TP 32-100/4

Port-to-port length
[mm]

TP 32-80/4

32

16

0.25

340

TP 32-100/4

32

16

0.37

340

TP 40-90/4

40

16

0.18

320

TP 40-100/4

40

16

0.55

340

TP 32-80/4
TP 40

TP 40-100/4

-90/
4

/165

3
2

Replacement kit
Type

138

Product number

TP 32-80/4

Not available

TP 32-100/4

Not available

TP 40-90/4

96497637

TP 40-100/4

96097993

10

12

14

16 Q [m/h]

TM02 7889 1104

Type

Replacement list

TP, TPD

Replacement of LM 40-200/191
Type
LM 40-200/191

Flange size
DN

Pressure
stage
PN

40

16

P2
[kW]
0.55

Port-to-port length
[mm]

H
[m]

LM 40-200/191

LM =

14

50 Hz

TP =

390
12
TP 32-120/4
10

TP
replacement

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

TP 32-120/4

32

16

0.55

440

TP 40-100/4

40

16

0.55

340

TP 40-100/4

8
/191

Replacement kit
Type

Product number

TP 32-120/4

Not available

TP 40-100/4

96097993

0
0

10

12

14

16 Q [m/h]

TM02 7890 1104

Replacement of LM 40-200/205
Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

40

16

0.75

390

TP
replacement

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

TP 40-130/4

40

16

0.75

440

TP 40-180/2

40

10

0.55

250

LM 40-200/205

H
[m]

LM =
TP =

16

LM 40-200/205
50 Hz

14
12

TP 40-130/4

10
8
/205
6
TP 40-180/2

Replacement kit
Type

2
0

Product number

TP 40-130/4

Not available

TP 40-180/2

96097994

10

12

14

16 Q [m/h]

TM02 7891 1104

Flange size
DN

Type

Replacement of LM 50-125/117
Type
LM 50-125/117

Flange size
DN

Pressure
stage
PN

P2
[kW]

16

0.25

50

Port-to-port length
[mm]
425

H
[m]

LM =

5.5

TP 40-60/4

TP 40-60/4

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

40

10

0.25

250

50 Hz

5.0
/117

4.5

TP
replacement

LM 50-125/117

TP =

4.0
3.5
3.0

TP 40-60/4

2.5

Product number
96497645

2.0
1.5
0

10

12

14 Q [m/h]

TM02 7892 1104

Replacement kit
Type

139

Replacement list

TP, TPD

Replacement of LM 50-125/128
Type
LM 50-125/128

Flange size
DN

Pressure
stage
PN

50

16

P2
[kW]
0.37

Port-to-port length
[mm]
425

H
[m]
TP 50-60/2

7.0

LM 50-125/128

LM =

6.5

50 Hz

TP =

6.0

/128

5.5

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

5.0

TP 50-60/4

50

10

0.37

280

4.0

TP 50-60/2

50

10

0.37

280

TP
replacement

TP 50-60/4

4.5
3.5
2.5

Replacement kit
Type

2.0

Product number

TP 50-60/4

96497639

TP 50-60/2

96497639

1.5
0

8 10 12 14 16 18 20 22 Q [m/h]

TM02 7893 1104

3.0

Replacement of LM 50-160/154
P2
[kW]

Port-to-port length
[mm]

50

16

0.55

425

H
[m]
10

TP 40-120/2

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

TP 50-90/4

50

16

0.55

340

TP 50-60/4

50

10

0.37

280

TP 40-120/2

40

10

0.37

250

TP 50-60/2

50

10

0.37

280

TP 50-90/4
TP 50-60/4
TP 50-60/2

Product number
96097995

TP 50-60/4

96497639

TP 40-120/2

96497645

TP 50-60/2

96497639

Replacement of LM 50-160/165

LM 50-160/165

/154

TP 50-90/4

Type

Flange size
DN

Pressure
stage
PN

P2
[kW]

16

0.75

50

Port-to-port length
[mm]
425

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

12

LM =

10

TP =

16

0.55

340

50

16

0.55

340

TP 40-120/2

40

10

0.37

250

140

TP 50-90/4

96097995

TP 40-120/2

96497645

LM 50-160/165
50 Hz

TP 50-90/4

TP 40-100/4
TP 40-120/2

Not available

Q [m/h]

50

Product number

24

/165

TP 50-90/4

TP 40-100/4

20

TP 40-100/4

Replacement kit
Type

16

H
[m]

TP
replacement

50 Hz

Flange size
DN

Replacement kit
Type

LM 50-160/154

TP =

9
8

TP
replacement

LM =

TM02 7894 1104

LM 50-160/154

Pressure
stage
PN

2
0

10 12 14 16 18

Q [m/h]

TM02 7895 1104

Type

Flange size
DN

Replacement list

TP, TPD

Replacement of LM 50-200/189
Type
LM 50-200/189

Flange size
DN

Pressure
stage
PN

50

16

P2
[kW]
0.75

Port-to-port length
[mm]

H
[m]
13

425

12

LM =

TP 40-130/4

LM 50-200/189

TP =

50 Hz

/189

11
10

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

9
TP 50-90/4

TP 50-110/4

50

16

0.75

440

TP 40-130/4

40

16

0.75

440

TP 50-90/4

50

16

0.55

340

TP 50-110/4

5
4

Replacement kit
Type

Product number

TP 50-110/4

Not available

TP 40-130/4

Not available

TP 50-90/4

96097995

2
0

10 12 14 16 18

Q [m/h]

TM02 7896 1104

TP
replacement

Replacement of LM 50-200/202

LM 50-200/202

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

50

16

1.1

425

H
[m]
TP 40-160/4

16
14

LM 50-200/202

LM =
TP =

50 Hz

/202

12

TP
replacement

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

TP 50-130/4

50

16

1.1

440

TP 40-160/4

40

16

1.1

440

TP 50-180/2

50

10

0.75

280

10

TP 50-130/4

8
6
4

Replacement kit
Type

TP 50-180/2
2

Product number

TP 50-130/4

Not available

TP 40-160/4

Not available

TP 50-180/2

96497639

Replacement of LM 65-125/133
Type
LM 65-125/133

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

65

16

0.55

475

TP 65-60/4

12

H
[m]

16

20

LM =

6.0

24

5.5

Q [m/h]

LM 65-125/133
50 Hz

TP =
TP 65-60/4

5.0

TP
replacement

TM02 7897 1104

Type

Flange size
DN

4.5

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

65

10

0.55

340

4.0
3.5
3.0

TP 65-60/4

2.5

Product number
96497643

/133

2.0
1.5
0

12

16

20

24

28

32

Q [m/h]

TM02 7898 1104

Replacement kit
Type

141

Replacement list

TP, TPD

Replacement of LM 65-160/158
Type
LM 65-160/158

Flange size
DN

Pressure
stage
PN

P2
[kW]

16

0.75

65

Port-to-port length
[mm]
475

H
[m]

LM =

10
TP 65-90/4

TP 65-90/4

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

65

16

0.75

360

50 Hz

/158

TP
replacement

LM 65-160/158

TP =

7
6
5

Replacement kit
Type
TP 65-90/4

Product number

96497641

12

16

20

24

28 Q [m/h]

TM02 7899 1104

Replacement of LM 65-160/173
Type
LM 65-160/173

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

65

16

1.1

475

H
[m]
12
TP 65-110/4

11

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

TP 65-90/4

65

16

0.75

360

TP 65-110/4

65

16

1.1

475

50 Hz

/173

10

TP
replacement

LM 65-160/173

LM =
TP =

TP 65-90/4

9
8
7

Product number

TP 65-90/4

96497641

TP 65-110/4

Not required

4
0

12

16

20

24

28

32 Q [m/h]

TM02 7900 1104

Replacement kit
Type

Replacement of LM 65-200/187
Type
LM 65-200/187

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

65

16

1.5

475

H
[m]
15

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

TP 65-130/4

65

16

1.5

475

TP 65-180/2

65

10

1.5

340

50 Hz

/187

12

Flange size
DN

LM 65-200/187

14
13

TP
replacement

LM =
TP =

TP 65-180/2

TP 65-130/4

11
10
9
8

142

Product number

TP 65-130/4

Not required

TP 65-180/2

96497643

10

15

20

25

30

35

40 Q [m/h]

TM02 7901 1104

Replacement kit
Type

Replacement list

TP, TPD

Replacement of LM 65-200/202
Type
LM 65-200/202

Flange size
DN

Pressure
stage
PN

P2
[kW]

16

2.2

65

Port-to-port length
[mm]
475

H
[m]
17

LM =

LM 65-200/202

TP =

16

50 Hz

TP 65-150/4

15
14

Flange size
DN

Pressure
stage
PN

13

P2
[kW]

Port-to-port length
[mm]

12

TP 65-130/4

11

TP 65-130/4

65

16

1.5

475

10

TP 65-150/4

65

16

2.2

475

TP 65-180/2

65

10

1.5

340

/202

7
6

Replacement kit
Type

Product number

TP 65-130/4

Not required

TP 65-150/4

Not required

TP 65-180/2

96497643

TP 65-180/2

4
0

12 16 20 24 28 32 36

Q [m/h]

TM02 7902 1104

TP
replacement

Replacement of LM 80-125/136
Type
LM 80-125/136

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

80

16

0.75

525

H
[m]
LM =
TP =

TP 80-60/4

6.0
5.5

LM 80-125/136
50 Hz

/136

5.0

TP
replacement
TP 80-60/4

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

80

10

0.75

360

4.5
4.0
3.5

2.5

Replacement kit
Type
TP 80-60/4

2.0
0

Product number

Replacement of LM 80-125/140

H
[m]

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

80

16

1.1

525

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

5.0

TP 80-70/4

80

16

1.1

440

4.0

TP 80-60/4

80

10

0.75

360

3.5

Type
LM 80-125/140

10

20

30

40

50

Q [m/h]

96545597

TP 80-70/4

7.0

/140

6.5

LM =

TM02 8883 1104

3.0

LM 80-125/140

TP =

50 Hz

TP 80-60/4

6.0
5.5

TP
replacement

4.5

Product number

TP 80-70/4

96545605

TP 80-60/4

96545597

2.5
2.0
0

10

20

30

40

50

60

Q [m/h]

TM02 8884 1104

3.0

Replacement kit
Type

143

Replacement list

TP, TPD

Replacement of LM 80-160/162
Type
LM 80-160/162

Flange size
DN

Pressure
stage
PN

80

16

P2
[kW]
1.5

Port-to-port length
[mm]

H
[m]

LM 80-160/162

LM =

10

50 Hz

TP =

525
9

TP
replacement
TP 80-90/4

TP 80-90/4

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

80

16

1.5

440

7
6

Replacement kit
Type
TP 80-90/4

Product number

/162

96545605

10

20

30

40

50

60

Q [m/h]

TM02 8885 1104

Replacement of LM 80-160/168

LM 80-160/168

Pressure
stage
PN

P2
[kW]

16

2.2

80

Port-to-port length
[mm]
525

H
[m]
11

TP 80-110/4

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

TP 80-90/4

80

16

1.5

440

TP 80-110/4

80

16

2.2

440

50 Hz

10
TP 80-90/4

TP
replacement

LM 80-160/168

LM =
TP =

8
7
6
5

Replacement kit
Type

Product number

TP 80-90/4

96545605

TP 80-110/4

96545605

Replacement of LM 80-200/187
Type
LM 80-200/187

/168

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

80

16

2.2

525

10

20

H
[m]
15

TP 80-150/4

14

TP 80-140/2

30

40

50

LM =
TP =

60

70 Q [m/h]

TM02 8886 1104

Type

Flange size
DN

LM 80-200/187
50 Hz

13
/187

12

TP
replacement

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

TP 80-110/4

80

16

2.2

440

TP 80-140/2

80

16

2.2

360

TP 80-150/4

80

16

3.0

500

11

TP 80-110/4

10
9
8

Replacement kit
Type

144

Product number

TP 80-110/4

96545605

TP 80-140/2

96545597

TP 80-150/4

96545607

5
0

10

20

30

40

50

60

70 Q [m/h]

TM02 8887 1104

7
6

Replacement list

TP, TPD

Replacement of LM 80-200/200
Type
LM 80-200/200

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

80

16

3.0

525

H
[m]
15

TP 80-150/4

14

LM =
TP =

LM 80-200/200
50 Hz

/200

13

TP
replacement

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

TP 80-150/4

80

16

3.0

500

12
11
10
9

Replacement kit
Type
TP 80-150/4

Product number

96545607

10

20

30

40

50

60

70 Q [m/h]

TM02 8888 1104

Replacement of LM 80-200/210
Type
LM 80-200/210

Flange size
DN

Pressure
stage
PN

P2
[kW]

16

4.0

80

Port-to-port length
[mm]
525

H
[m]

LM =

16
15
14

LM 80-200/210
50 Hz

TP =

/210
TP 80-150/4

13

TP
replacement

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

12

TP 80-150/4

80

16

3.0

500

11
10

Replacement kit
Type
TP 80-150/4

8
7

Product number

96545607

Replacement of CLM 100-158


Type
CLM 100-158

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

100

16

2.2

500

10

20

H
[m]
10
TP 80-90/4

30

40

50

60

CLM =
TP =

70

80 Q [m/h]

TM02 8889 1104

CLM 100-158
50 Hz

8
TP 80-70/4

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

TP 80-70/4

80

16

1.1

440

TP 80-90/4

80

16

1.5

440

TP
replacement

Replacement kit
Type

Product number

TP 80-70/4

Not available

TP 80-90/4

Not available

-158

1
0

10

20

30

40

50

60

70 Q [m/h]

TM02 8890 1104

3
2

145

Replacement list

TP, TPD

Replacement of CLM 100-178


Type
CLM 100-178

Flange size
DN

Pressure
stage
PN

P2
[kW]

16

2.2

100

Port-to-port length
[mm]
500

H
[m]

CLM =

11

TP 80-110/4

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

TP 80-90/4

80

16

1.5

440

TP 80-110/4

80

16

2.2

440

50 Hz

10
TP 80-90/4

TP
replacement

CLM 100-178

TP =

8
7
6
5

Replacement kit
Type

Product number

TP 80-90/4

Not available

TP 80-110/4

Not available

-178

2
0

10

20

30

40

50

60

70

80 Q [m/h]

TM02 8891 1104

Replacement of CLM 100-203


Type
CLM 100-203

Flange size
DN

Pressure
stage
PN

P2
[kW]

16

3.0

100

Port-to-port length
[mm]
500

H
[m]
15

TP 80-150/4

14
13

CLM =
TP =

CLM 100-203
50 Hz

-203

12
11

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

10

TP 80-110/4

80

16

2.2

440

TP 80-150/4

80

16

3.0

500

TP
replacement

TP 80-110/4

9
7
5

Replacement kit
Type

4
3

Product number

TP 80-110/4

Not available

TP 80-150/4

Not available

Replacement of CLM 100-217


Type
CLM 100-217

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

100

16

4.0

500

10

20 30 40 50 60 70 80

H
[m]

CLM =
TP =

20
18

Q [m/h]

TM02 8892 1104

CLM 100-217
50 Hz

TP 80-170/4

16
14

TP
replacement

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

12

TP 80-150/4

80

16

3.0

500

10

TP 80-170/4

80

16

4.0

500

TP 80-150/4

Replacement kit
Type

146

-217

Product number

TP 80-150/4

Not available

TP 80-170/4

Not available

2
0

10 20 30 40 50 60 70 80 90

Q [m/h]

TM02 8893 1104

Replacement list

TP, TPD

Replacement of CLM 100-225


Type
CLM 100-225

Flange size
DN

Pressure
stage
PN

P2
[kW]

16

5.5

100

TP
replacement

Flange size
DN

Pressure
stage
PN

TP 80-170/4

80

16

Port-to-port length
[mm]
500

P2
[kW]

Port-to-port length
[mm]

4.0

500

H
[m]

CLM =

20

CLM 100-225
50 Hz

TP =

18

-225

16

TP 80-170/4

14
12
10
8

Replacement kit
Type
TP 80-170/4

Product number

Not available

0 10 20 30 40 50 60 70 80 90 100 Q [m/h]

TM02 8894 1104

Replacement of CLM 125-160


Type
CLM 125-160

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

125

16

2.2

620

H
[m]
TP 100-60/4

CLM =
TP =

CLM 125-160
50 Hz

6
-160
5

TP
replacement

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

TP 100-30/4

100

10

0.55

450

TP 100-60/4

100

10

1.1

450

4
TP 100-30/4
3

Replacement kit
Type

Product number

TP 100-30/4

Not available

TP 100-60/4

Not available

CLM 125-177

20 30 40 50 60 70 80

H
[m]

Replacement of CLM 125-177


Type

10

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

125

16

2.2

620

CLM =
-177

TP =

Q [m/h]

TM02 8895 1104

CLM 125-177
50 Hz

7
6

TP 100-60/4

TP
replacement

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

TP 100-60/4

100

10

1.1

450

TP 100-70/4

100

16

1.5

500

TP 100-70/4

1
0

Replacement kit
Type

Product number

TP 100-60/4

Not available

TP 100-70/4

Not available

0 10 20 30 40 50 60 70 80 90 100 Q [m/h]

TM02 8896 1104

147

Replacement list

TP, TPD

Replacement of CLM 125-197


Type
CLM 125-197

Flange size
DN

Pressure
stage
PN

P2
[kW]

16

3.0

125

Port-to-port length
[mm]
620

H
[m]

CLM =

11

TP 100-110/4

CLM 125-197
50 Hz

TP =

10
9

TP
replacement

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

TP 100-90/4

100

16

2.2

500

TP 100-110/4

100

16

3.0

500

TP 100-90/4

7
6
5

Replacement kit
Type

Product number

TP 100-90/4

Not available

TP 100-110/4

Not available

-197

2
0

20

40

60

80

100

120

Q [m/h]

TM02 8897 1104

Replacement of CLM 125-211


Type
CLM 125-211

Flange size
DN

Pressure
stage
PN

125

16

P2
[kW]
4.0

Port-to-port length
[mm]
620

H
[m]
15
14

TP 100-130/4

13

CLM =
TP =

CLM 125-211
50 Hz

-211

12

TP
replacement

Flange size
DN

Pressure
stage
PN

11

P2
[kW]

Port-to-port length
[mm]

10

TP 100-110/4

100

16

3.0

500

TP 100-130/4

100

16

4.0

550

TP 100-110/4

Replacement kit
Type

5
4

Product number

TP 100-110/4

Not available

TP 100-130/4

Not available

Replacement of CLM 125-228


Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

125

16

5.5

620

TP
replacement

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

TP 100-130/4

100

16

4.0

550

TP 100-170/4

100

16

5.5

550

Type
CLM 125-228

20

40

60

80

100

120

Q [m/h]

TM02 8898 1104

7
6

H
[m]
CLM =

18

TP 100-170/4

16

-228

TP =

CLM 125-228
50 Hz

14
TP 100-130/4

12
10
8

Replacement kit
Type

148

Product number

TP 100-130/4

Not available

TP 100-170/4

Not available

2
0

20

40

60

80

100 120 140 Q [m/h]

TM02 8899 1104

Replacement list

TP, TPD

Replacement of CLM 125-242


Type
CLM 125-242

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

125

16

7.5

620

H
[m]
22
TP 100-200/4

20

CLM =
TP =

CLM 125-242
50 Hz

18
16

TP
replacement

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

TP 100-200/4

100

16

7.5

670

14
12
10

TP 100-200/4

Product number

Not available

-242

2
0

Replacement of CLM 150-195


Type
CLM 150-195

Flange size
DN

Pressure
stage
PN

150

16

P2
[kW]
5.5

Port-to-port length
[mm]
700

20 40 60 80 100 120 140 160

H
[m]

CLM =
TP =

11

Q [m/h]

TM02 8900 1104

Replacement kit
Type

CLM 150-195
50 Hz

10
9
8

TP
replacement

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

TP 125-110/4

125

16

4.0

620

TP 125-110/4

7
6
5
4

TP125-110/4

Product number

Not available

-195

1
0 20 40 60 80 100 120 140 160 180 200 Q [m/h]

TM02 8901 1104

Replacement kit
Type

Replacement of CLM 150-216


Type
CLM 150-216

Flange size
DN

Pressure
stage
PN

150

16

P2
[kW]

Port-to-port length
[mm]

H
[m]

7.5

CLM 150-216

CLM =

14

50 Hz

TP =

700
12

TP
replacement

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

TP 125-130/4

125

16

5.5

620

TP 150-130/4

150

16

7.5

800

10
TP 150-130/4

TP 125-130/4

8
6
4

-216

Product number

TP 125-130/4

Not available

TP 150-130/4

Not available

2
0
0

40

80

120

160

200

240

Q [m/h]

TM02 8902 1104

Replacement kit
Type

149

Replacement list

TP, TPD

Replacement of CLM 150-242


Pressure
stage
PN

P2
[kW]

150

16

11.0

TP
replacement

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

TP 150-160/4

150

16

11.0

800

Type
CLM 150-242

Flange size
DN

Port-to-port length
[mm]
700

H
[m]
CLM =

20

TP =

-242

18
16

CLM 150-242
50 Hz

TP 150-160/4

14
12
10

TP 150-160/4

Product number
6

Not available

4
0

Replacement of CLM 150-264


Type
CLM 150-264

Flange size
DN

Pressure
stage
PN

P2
[kW]

16

15.0

150

Port-to-port length
[mm]
700

TP
replacement

Flange size
DN

TP 150-200/4

150

16

80

H
[m]

120 160 200 240 280 Q [m/h]

CLM =

24

TP =

-264

22
20

Pressure
stage
PN

40

TM02 8903 1104

Replacement kit
Type

CLM 150-264
50 Hz

TP 150-200/4

18

P2
[kW]

Port-to-port length
[mm]

16

15.0

800

14
12

TP 150-200/4

10

Product number

Not available

6
0

40

80 120 160 200 240 280 320Q [m/h]

TM02 8904 1104

Replacement kit
Type

Replacement of CLM 150-271


Type
CLM 150-271

Flange size
DN

Pressure
stage
PN

P2
[kW]

16

18.5

150

Port-to-port length
[mm]
700

H
[m]

CLM =

26

TP =

-271

24
22

CLM 150-271
50 Hz

TP 150-220/4

20

TP
replacement

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

TP 150-220/4

150

16

18.5

800

18
16
14

TP 150-220/4

12

Product number
Not available

10
8
6
0

150

40

80 120 160 200 240 280 320Q [m/h]

TM02 8905 1104

Replacement kit
Type

Replacement list

TP, TPD

Replacement of CLM 150-278


Type
CLM 150-278

Flange size
DN

Pressure
stage
PN

P2
[kW]

16

22.0

150

Port-to-port length
[mm]
700

H
[m]
28

CLM =
TP =

-278

26

CLM 150-278
50 Hz

TP 150-250/4

24
22

TP
replacement

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

TP 150-250/4

150

16

22.0

800

20
18
16

TP 150-250/4

14

Product number

12

Not available

10
8
0

40 80 120 160 200 240 280 320

Q [m/h]

TM02 8906 1104

Replacement kit
Type

Replacement of LP 50-125/132
Type
LP 50-125/132

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

50

16

1.1

425

H
[m]

LP =

TP 40-230/2

24

LP 50-125/132
50 Hz

TP =

22
20

TP
replacement

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

18

TP 40-230/2

40

16

1.1

320

16
14

TP 40-230/2

Product number

12

96097992

10

/132

8
0

10

12

14

16 Q [m/h]

TM02 7903 1104

Replacement kit
Type

Replacement of LP 50-125/142
Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

50

16

1.5

425

TP
replacement

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

TP 32-250/2

32

16

1.5

340

TP 40-270/2

40

16

1.5

320

LP 50-125/142

H
[m]
28

LP 50-125/142
50 Hz

26
24

Replacement kit
Type

LP =
TP =

TP 40-270/2

TP 32-250/2

22
20
18
16
14

Product number

12

TP 32-250/2

Not available

10

TP 40-270/2

96097992

/142

10

12

14

16 Q [m/h]

TM02 7904 1104

Type

151

Replacement list

TP, TPD

Replacement of LP 50-160/152
Type
LP 50-160/152

Flange size
DN

Pressure
stage
PN

50

16

P2
[kW]
2.2

Port-to-port length
[mm]

H
[m]
34

425

32

LP =
TP 32-320/2

TP =

LP 50-160/152
50 Hz

30
28

TP
replacement

Flange size
DN

Pressure
stage
PN

TP 32-320/2

32

16

2.2

340

22

TP 40-270/2

40

16

1.5

320

20

Port-to-port length
[mm]

TP 40-270/2

24

18

Replacement kit
Type

Product number

14

TP 32-320/2

Not available

12

TP 40-270/2

96097992

Replacement of LP 50-160/165
Type
LP 50-160/165

/152

16

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

50

16

3.0

425

H
[m]
42

10 12 14 16 18

LP =

40

TP 32-380/2

38

TP =

Q [m/h]

TM02 7905 1104

P2
[kW]

26

LP 50-160/165
50 Hz

/165

36
34

TP
replacement

Flange size
DN

Pressure
stage
PN

P2
[kW]

32

Port-to-port length
[mm]

30

TP 32-320/2

32

16

2.2

340

28

TP 32-380/2

32

16

3.0

340

26

TP 32-320/2

Replacement kit
Type

22
20

Product number

TP 32-320/2

Not available

TP 32-380/2

Not available

18
0

Replacement of LP 50-200/185
Type
LP 50-200/185

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

50

16

4.0

425

H
[m]

10 12 14 16 18

LP =

56

TP =

52

Q [m/h]

TM02 7906 1104

24

LP 50-200/185
50 Hz

/185

48
44

TP
replacement

Flange size
DN

Pressure
stage
PN

TP 32-460/2

32

16

P2
[kW]

Port-to-port length
[mm]

4.0

440

TP 32-460/2

40
36
32
28

TP 32-460/2

24

Product number
Not available

20
16
0

152

8 10 12 14 16 18 20 Q [m/h]

TM02 7907 1104

Replacement kit
Type

Replacement list

TP, TPD

Replacement of LP 50-200/205
Type
LP 50-200/205

Flange size
DN

Pressure
stage
PN

P2
[kW]

16

5.5

50

Port-to-port length
[mm]
425

H
[m]

LP =

60

LP 50-200/205
50 Hz

TP =

56
52

TP
replacement

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

TP 32-580/2

32

16

5.5

440

48
44

TP 32-580/2

40
36

TP 32-580/2

32

Product number

/205

28

Not available

24
0

Replacement of LP 65-125/104
Type
LP 65-125/104

Pressure
stage
PN

P2
[kW]

65

16

1.5

Flange size
DN

Pressure
stage
PN

Flange size
DN

Port-to-port length
[mm]
475

H
[m]
16

TP 65-180/2

65

10

P2
[kW]
1.5

Port-to-port length
[mm]
340

12

16

20

LP =
/104

15

24

Q [m/h]

LP 65-125/104

TP =

50 Hz

14
13

TP
replacement

TM02 7908 1104

Replacement kit
Type

TP 65-180/2

12
11
10
9

TP 65-180/2

Product number

96497643

6
5
0

Replacement of LP 65-125/117
Type
LP 65-125/117

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

65

16

2.2

475

H
[m]
19

10

15

20

25

30

LP =
TP 65-190/2

18

35

40 Q [m/h]

TM02 7909 1104

Replacement kit
Type

LP 65-125/117

TP =

50 Hz

17
16
15

TP
replacement

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

TP 65-190/2

65

16

2.2

360

14
13
12

TP 65-190/2

10

Product number
96497641

/117

9
8
0

10

15

20

25

30

35

40

Q [m/h]

TM02 7910 1104

11

Replacement kit
Type

153

Replacement list

TP, TPD

Replacement of LP 65-125/128
Type
LP 65-125/128

Flange size
DN

Pressure
stage
PN

P2
[kW]

16

3.0

65

Port-to-port length
[mm]
475

H
[m]
23

LP =

22

TP 65-230/2

21

/128

LP 65-125/128

TP =

50 Hz

20

TP
replacement

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

TP 65-230/2

65

16

3.0

360

19
18
17
16
15

TP 65-230/2

14

Product number

13

96497641

12
11
0

Replacement of LP 65-160/154
Type
LP 65-160/154

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

65

16

4.0

475

10

15

H
[m]

20

25

30

35

LP =

32

TP 40-300/2

40

Q [m/h]

TM02 7911 1104

Replacement kit
Type

LP 65-160/154
50 Hz

TP =

30
28

TP 50-290/2

26

TP
replacement

Flange size
DN

Pressure
stage
PN

TP 40-300/2

40

16

3.0

340

22

TP 50-290/2

50

16

3.0

340

20

P2
[kW]

Port-to-port length
[mm]

24

Product number

TP 40-300/2

96497647

TP 50-290/2

96497649

/154

16
14
0

12

16

20

24

28

32 Q [m/h]

TM02 7912 1104

18

Replacement kit
Type

Replacement of LP 65-160/165
Type
LP 65-160/165

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

65

16

5.5

475

H
[m]

LP =

38

TP 40-360/2

36

LP 65-160/165

TP =

50 Hz

34
32

TP
replacement

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

TP 40-360/2

40

16

4.0

340

TP 50-360/2

50

16

4.0

340

30
TP 50-360/2

28
26
24

154

22

Product number

20

TP 40-360/2

96497647

18

TP 50-360/2

96497649

/165
0

12

16

20

24

28

32

Q [m/h]

TM02 7913 1104

Replacement kit
Type

Replacement list

TP, TPD

Replacement of LP 65-200/189
Type
LP 65-200/189

Flange size
DN

Pressure
stage
PN

65

16

P2
[kW]
5.5

Port-to-port length
[mm]

H
[m]
LP =
45

475

35

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

TP 50-430/2

50

16

5.5

340

TP 40-360/2

40

16

4.0

340

50 Hz

TP 50-430/2

40

TP
replacement

LP 65-200/189

TP =

TP 40-360/2

30
25

Replacement kit
Type
TP 50-430/2

96497649

TP 40-360/2

96497647

/189

15

Product number

10
0

10

15

20

25

30

35

40 Q [m/h]

TM02 7914 1104

20

Replacement of LP 65-200/202
Type
LP 65-200/202

Flange size
DN

Pressure
stage
PN

P2
[kW]

16

7.5

65

Port-to-port length
[mm]
475

H
[m]

LP =

TP 40-580/2

60

LP 65-200/202
50 Hz

TP =

55
50

TP
replacement

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

TP 40-580/2

40

16

7.5

440

TP 50-440/2

50

16

7.5

440

40
35
30
25

Product number

20

TP 40-580/2

Not available

15

TP 50-440/2

Not available

Replacement of LP 80-125/124
Type
LP 80-125/124

Flange size
DN

Pressure
stage
PN

80

/202

16

10

15

20

25

30

35

40

Q [m/h]

TM02 7915 1104

Replacement kit
Type

TP 50-440/2

45

H
[m]

P2
[kW]
3.0

Port-to-port length
[mm]

22

525

20

LP 80-125/124

LP =
TP 80-210/2

50 Hz

TP =

18

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

TP 80-180/2

80

16

3.0

360

TP 80-210/2

80

16

4.0

360

16

TP 80-180/2

14
12
10

Replacement kit
Type

/124

Product number

TP 80-180/2

96545597

TP 80-210/2

96545597

6
0

10

20

30

40

50

60

Q [m/h]

TM02 7916 1104

TP
replacement

155

Replacement list

TP, TPD

Replacement of LP 80-125/133
Pressure
stage
PN

80

16

P2
[kW]
4.0

Port-to-port length
[mm]
525

H
[m]
TP 80-240/2

24
22

TP
replacement

Flange size
DN

Pressure
stage
PN

TP 80-210/2

80

16

4.0

360

TP 80-240/2

80

16

5.5

360

Port-to-port length
[mm]

/133
TP 80-210/2

18
16
14
12

Product number

10

96545597

TP 80-240/2

96545597

Replacement of LP 80-160/149
Flange size
DN

P2
[kW]

Port-to-port length
[mm]

80

16

5.5

525

TP
replacement

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

24

TP 65-260/2

65

16

4.0

360

20

TP 65-340/2

65

16

5.5

360

Product number
96497650

TP 65-340/2

96497650

40

50

60

70

80 Q [m/h]

TP 65-340/2

LP 80-160/149
50 Hz

TP =

32
TP 65-260/2

16
/149

8
0

Replacement of LP 80-160/164

10

20

30

40

50

60

Q [m/h]

H
[m]

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

80

16

7.5

525

TP
replacement

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

28

TP 65-340/2

65

16

5.5

360

24

TP 65-410/2

65

16

7.5

360

LP 80-160/164

30

12

TP 65-260/2

Type

20

LP =

36

28

Replacement kit
Type

10

H
[m]

Pressure
stage
PN

LP 80-160/149

50 Hz

20

TP 80-210/2

Type

LP 80-125/133

LP 80-160/164

LP =

40

50 Hz

TP =

36
32

TP 65-340/2

20

/164

16

Replacement kit
Type

156

Product number

TP 65-340/2

96497650

TP 65-410/2

96497650

TM02 7917 1104

Replacement kit
Type

P2
[kW]

LP =
TP =

26

TM02 7918 1104

LP 80-125/133

Flange size
DN

12
0

10

20

30

40

50

60

Q [m/h]

TM02 7919 1104

Type

Replacement list

TP, TPD

Replacement of LP 80-200/180

LP 80-200/180

Flange size
DN

Pressure
stage
PN

80

16

P2
[kW]
11.0

Port-to-port length
[mm]

H
[m]

/180

50
45

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

TP 65-460/2

65

16

11.0

475

Replacement kit
Type
TP 65-460/2

50 Hz

TP =

525

TP
replacement

LP 80-200/180

LP =

55

TP 65-460/2

40
35
30

Product number

25

Not available

20
0

10

20

30

40

50

60

70 Q [m/h]

TM02 7920 1104

Type

Replacement of LP 80-200/202
Type
LP 80-200/202

Flange size
DN

Pressure
stage
PN

P2
[kW]

16

15.0

80

Port-to-port length
[mm]
525

H
[m]
LP =

65
60

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

TP 65-550/2

65

16

15.0

475

50 Hz

/202

55

TP
replacement

LP 80-200/202

TP =

TP 65-550/2

50
45
40

TP 65-550/2

35

Product number

30

Not available

25
0

10

20

30

40

50

60

70

80 Q [m/h]

TM02 7921 1104

Replacement kit
Type

Replacement of LP 100-125/121
Type
LP 100-125/121

Flange size
DN

Pressure
stage
PN

100

16

P2
[kW]
4.0

Port-to-port length
[mm]
550

H
[m]
18

LP =
TP 100-160/2

17

TP =

LP 100-125/121
50 Hz

16
15

TP
replacement

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

14

TP 100-160/2

100

16

4.0

500

12

13
11

TP 100-160/2

10

Product number

96545610

/121

7
0

10

20 30 40 50 60 70 80

Q [m/h]

TM02 8875 1104

Replacement kit
Type

157

Replacement list

TP, TPD

Replacement of LP 100-125/130
Type
LP 100-125/130

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

100

16

5.5

550

H
[m]

LP =
TP =

22

LP 100-125/130
50 Hz

20
18

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

TP 100-200/2

100

16

5.5

500

Replacement kit
Type
TP 100-200/2

16
14
12

Product number

TP 100-200/4
/130

10

96545610

8
0

Replacement of LP 100-125/137
Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

100

16

7.5

550

TP
replacement

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

TP 100-240/2

100

16

7.5

500

Type
LP 100-125/137

20

40

60

80

100 120 140 Q [m/h]

TM02 8876 1104

TP
replacement

H
[m]
26

TP 100-240/2

LP 100-125/137

LP =
TP =

50 Hz

24
22
20
18
16

TP 100-240/2

14

Product number

/137

12

96545610

10
0

20

40

60

80

100

120

Q [m/h]

TM02 8877 1104

Replacement kit
Type

Replacement of LP 100-160/152
Type
LP 100-160/152

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

100

16

11.0

550

H
[m]
34

TP 80-340/4

LP =
TP =

LP 100-160/152
50 Hz

32
30
28

TP
replacement

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

TP 80-330/2

80

16

11.0

440

TP 80-340/4

80

16

11.0

620

26

TP 80-330/2

24
22
20

158

18

Product number

16

TP 80-330/2

96545611

14

TP 80-340/4

Not available

/152
0

20

40

60

80

100

120

Q [m/h]

TM02 8878 1104

Replacement kit
Type

Replacement list

TP, TPD

Replacement of LP 100-160/168
Type
LP 100-160/168

Flange size
DN

Pressure
stage
PN

P2
[kW]

16

15.0

100

Port-to-port length
[mm]
550

H
[m]
42

LP =
TP =

/168

40

LP 100-160/168
50 Hz

TP 80-400/2

38
36

TP
replacement
TP 80-400/2

Flange size
DN

Pressure
stage
PN

P2
[kW]

16

15.0

80

Port-to-port length
[mm]
440

34
32
30
28
26

TP 80-400/2

24

Product number

22

96545611

20
18
0

20

40

60

80

100 120 140 Q [m/h]

TM02 8879 1104

Replacement kit
Type

Replacement of LP 100-200/183
Type
LP 100-200/183

Flange size
DN

Pressure
stage
PN

P2
[kW]

16

18.5

100

Port-to-port length
[mm]
550

H
[m]
52

TP 80-520/2

LP =
TP =

LP 100-200/183
50 Hz

48
44

TP
replacement

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

40

TP 80-400/2

80

16

15.0

440

36

TP 80-520/2

80

16

18.5

500

32
28

Product number

TP 80-400/2

96545611

TP 80-520/2

Not available

/183

24
20
0

20

40

60

80

100 120 140 Q [m/h]

TM02 8880 1104

Replacement kit
Type

TP 80-400/2

Replacement of LP 100-200/191
Type
LP 100-200/191

Flange size
DN

Pressure
stage
PN

P2
[kW]

16

22.0

100

Port-to-port length
[mm]
550

H
[m]
LP =
TP =

56
/191

52
48

LP 100-200/191
50 Hz

TP 80-520/2

44

TP
replacement

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

40

TP 80-520/2

80

16

18.5

500

36
32

TP 80-520/2

28

Product number
Not available

24
20
0

20

40

60

80

100 120 140 Q [m/h]

TM02 8881 1104

Replacement kit
Type

159

Replacement list

TP, TPD

Replacement of LP 100-200/210

LP 100-200/210

Flange size
DN

Pressure
stage
PN

P2
[kW]

16

30.0

100

Port-to-port length
[mm]
550

H
[m]

LP =

75

TP =

70

Flange size
DN

Pressure
stage
PN

P2
[kW]

Port-to-port length
[mm]

TP 80-570/2

80

16

22.0

500

TP 80-700/2

80

16

30.0

500

Replacement kit
Type

160

50 Hz

TP 80-700/2

65

TP
replacement

LP 100-200/210

/210

60

TP 80-570/2

55
50
45
40

Product number

35

TP 80-570/2

Not available

30

TP 80-700/2

Not available

20

40

60

80 100 120 140 160Q [m/h]

TM02 8882 1104

Type

Further product documentation

In addition to this printed data booklet, Grundfos offers


the following sources of product documentation.
WinCAPS
WebCAPS.

WinCAPS
WinCAPS is a Windows-based Computer Aided
Product Selection program containing information on
more than 90,000 Grundfos products.
cd-wincaps

Available on CD-ROM in more than 15 languages,


WinCAPS offers
detailed technical information
selection of the optimum pump solution
dimensional drawings of each pump

Fig. 32 WinCAPS CD-ROM

detailed service documentation


installation and operating instructions
wiring diagrams of each pump.

Click Sizing and select the


most suitable pump for your
application.

WinCAPS

Click Catalogue and select


a product from the extensive
product catalogue.

Fig. 33 WinCAPS

161

Further product documentation

WebCAPS
WebCAPS is a Web-based Compute Aided Product
Selection program and a web-version of WinCAPS.
WebCAPS is accessible on Grundfos homepage,
www.grundfos.com, and offers

detailed technical information


dimensional drawings of each pump
wiring diagrams of each pump.

Click Service to
find information on
service kits and
spare parts.

Click Search
and select a product from the
extensive product
catalogue.

Click Replacement and select the


right replacement
pump based on the

Click Sizing and


select the most suitable pump for your
application.

Click CAD drawings


to select and download
CAD drawings in:
.stp
.dxf
.dwg

Being a registered user


click Log in to:
save your settings
define and save your
own units
save personalised
information.
Click Settings and
select your preferred
options.

WebCAPS_English

Click Catalogue
and select a product
from the extensive
product catalogue.

Click Literature to
select and download
Grundfos documentation by browsing the
product ranges or performing a specific
search.
Literature includes:
data booklets
installation and operating instructions
service etc.

Fig. 34 WebCAPS

162

163

Being responsible is our foundation


Thinking ahead makes it possible
Innovation is the essence

V7124417 0405
Repl. V7124417 0404

GB

GRUNDFOS A/S . DK-8850 Bjerringbro . Denmark


Telephone: +45 87 50 14 00
www.grundfos.com

Subject to alterations.

Potrebbero piacerti anche