Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
SERVICE MANUAL
MODEL:
DI-10
DISPLAY & KEYS. ......................... ------____---------------2-1. Display. --_____---------------2-2. Sign lamps. --------_____---------------2-3. Keys. SET UP. SPECIFICATIONS. ............................... ........................ ........................
3. 4.
5. FEATURES.
................. 9 6. OPERATION INSTRUCTION. -_---_____---------------9 6-1. Power ON. ___---------------10 6-2. One touch tare. _____---------------11 6-3. Digital tare. ------_ 12 6-4. Digital tare during weighing. _---------------6-5. Set point setting 13 _-------15 6-6. Addition and subtraction. _________--_---_-___----17 6-7. Counting. ___---------------6-8. NET/GROSS display 17 6-9. Data ti Time setting ----------------18 ___---------------19 6-lO.LB/KG conversion 7. a. 9. CALIBRATION. SPEC. LIST. . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 . . . . . . . . . . . . . . . . . . . . 25
1.
EXTERNAL
VIEW
Dl,-10
W=240 D=260
2.DISPLAY 2;1*Display
& KEYS.
H = 92 (mm)
for
set
pint
are
2-2.sign
,,.~~
lamps
,,
[-o-J
m [r]
is is
true
zero.
when tare
subtracted. is displayed. is out. stable reached reached reached condition. to to to "HI" "OK" "LO" set set set displayed.
c3i3 m [r) I] (1 (
Gross BATT.
when battery
in
point
2-3.Keys
* 0
-
Total
key
: Use for Use for addition. : Use : Use out. : Use for for for
and out
Plus
0
a-0 -
Minus
subtraction
ON/OFF
key
: Display
ON/OFF
key.(Not
for
main
power.)
Mode
key
: Weighing
conversion
key.
: Display
change
for
NET and
GROSS.
: Paper feed connection) : Set point "LO" . : Use for counting : Use for
key.(In
case
of
PRINTER
Set
. :=: 0 0
-13
programming
for
"HI'~,"OK"
and
Sample
of
sample
entry
on
Tare
key
reduction.
Re-zero
key
: Weight
display
re-zeroing.
CL 0 0
#
Clear
key
: Use
for
data
clear.
Code
key
: Use
for
programmed
code
number
read
out.
5 3.SET UP
l-Put display side on the soft cloth or similar. 2.Remove rear lid and brackets by 6 screws. 3.Fix the cable to connector A. 4.Remount the rear lid and brackects.
l.Remove the right side cover. 2.Remove the dry cell box. 3.Put the dry cell in the box. ( 6 pcs.) (Please pay attention to the polarity 4.Re-mount the dry cell box.
of the
dry
Cells)
4.
* Operating temperature * Operating humidity * Power consumption ANALOG SPEC: * * * * Input sensitivity Zero adj. range L/C applied voltage Temp. characteristic
. . . +4o*c . . . 85%
1 w/h.
* Speed of A/D conversion: * Non linearity DISPLAY_SPEC;: * Weight display * Tare * Set point 1 (LO) * Set point 2, (OK) * Set point 3 (HI) * Display total. * Weighing unit * Sign lamps * Filling graphic
: 0.5mV/V to 4mV/V -6 mV . . . 30 mV. : DC 12.V. : ZERO . ..+(0.2uV + 8ppm of ZERO)/"C SPAN _ ..+ 8 ppm/"c 8 or 16 times/set. (selectable) : 0.01 8
digits. digits. digits. digits. digits. "g","kg","lbs","oz" & "dwt" "ZERO","TARE","NET","GROSS" "BATT" "was", UHI", WOK", "Lo" : 2 kinds rough and fine.
: Model 150 II 16 digits/line. 5 x 7 dots/chars. : Dot impact printer Ink ribbon cartridge. : : : : : : : Date(MM.DD.YY.)...... Time(HH.MM) .. Code No. ...... Weight ... Total weight . No. of transaction... Signs "+" . ?'-'I . (1 ?I * . "T" . "kg" .
lb
. . . .
.. .. .. ..
.. .. .. ..
. . . .
2 digits each. 2 digits each. 6 digits. 6 digits. 6 digits. 4 digits. Addition Subtraction. Non addition. Total. kg mode. lb mode.
* Paper * Print
color
5.
FJZATURES
*, LCD graphic display is used for filling in indicator. * Battery drive available. (about 100 to 200 hours) * Up to 4 x 350o load cell can be drive in case AC/DC adaptor is used. ( in the case of battery drive, only one 350n load cell can be drive.) * 5 kinds of weighing mode kg,g,lbs,oz and dwt. * One touch tare, Digital tare, Digital tare during weighing. * Addition & subtraction. ? NET/GROSS conversion. * Automatic zero tracking. * Automatic print. * Automatic calibration. * Automatic power off. * Data out put by RS-232C for external device. (Option) * Set point data out put. (Option) * Built in printer. (Option) * Code No. printing. * Da-te & time printing. * Counting function. * Programmable scale capacity and scale interval. * Meets or exceeds the requirements of OIML class 3 in case of l/3000 display resolution.
9 6 OPERATION INSTRUCTION
ZERO : TARE : NET : GROSS: BATT.: l-Set then dry cell or AC/DC adaptor
W.S: HI : OK : LO :
Weight stable "HI" set point "OK" set point "LO" set point I, II
depress is
* P 1.03
0
Ea
1.0
11
program
II
* DiSDlaY _
I,
0 0 0 0 0 0
II
11
000000 to _ scrolls 999999 then all the sign weight unit and lamps, filling in graphic are displayed for checking purpose. you want to stop the
II
* If
10
2.Ready
to weigh. mxa
* After this page, all the descriptions are written based on 60.00kg/O.O2kg scale.
u m
. . I I -
(When unknown
tare
weight)
l-Place
tare
weight.
*Ready
to weigh.
3.Place (Ex.
4.Remove
tare
& weight
5.Depress
*Tare
0
*T 3
key. cleared.
OperatiOn.
II I
mm
O.!
*Ready
tare
weight)
(Ex.
2.34
kg)
2.Depress
0
*T3
key.
I4 II -
2.
II
4mn
I
3.Place *Ready tare weight 2.34 kg. to weigh.
5.Remove
tare
& weight.
ii -
1': 0
oa;
b-Depress *Tare is
0
+q 3
key.
cleared.
l-Place
5'1.5
2.Enter
tare
value
by numeric key.
6m'
3. Depress
0
+T 3
key.
4.Remove
tare
& weight.
5. Depress
0
*T3
key.
*Tare
is
cleared.
l-Depress
(5) 0
key.
II II
0.0
I,
II
*Scale capacity(60.00kg) is set automatically for "LO", "OK" & "HI" when no data. *See 2.Enter (Ex. "NOTE" set set set set Enter for the for detail. "LO". kg) kg kg II II ~ m
!
II
10.0
fsj 0 point
Enter
0
f9 point
Enter
5.Depress *Completed
fs>
key. to weigh.
& ready
NOTE :
graphic will set point. kg/O.02 kg. 45.02 30.02 15.02 0.02
are kg.
"L0"="0K"="H1"=60.00 kg kg kg kg
kg
step kg kg kg kg kg
kg,"HI"=30.00
0.02
to
10.00
kg
_ _ _
-10.02
to
20.00
I 20.02 to 30.00 kg
30.02
to
CAPACITY
l-Enter Ex.
Code Code
No.
by numeric
key.,, II 1
4.
I,
11 11
No.=123456
@.@@@a3 I! II II
2.Depress
0
#
key.
I, 0. 0 OmII
Ii
weight
then
depress
1
10.00 kg
0.
II
Olall
II
*Total weight appears and display flashes 4 times. u 4.Remove another 10.00 kg and place weight then depress Ex. 15.00 kg II 11
J 0 Orall
II
+ 0
5,
II
key.
*Total weight appears and display flashes 4 times. w key for correction.l[ (subtraction) II I,
II
5.Depress
0.
omjl
enter known
weight weight.
II I/
2.3
II
I II 11
(fjg4~@@
7.Depress then a L.2 depress key for addition,,
up total
weight.
0
*
key to cal
II
2.
II
4m11
II
0
* total
to
II
II
II
II
0.
OBll
.L,
samples m w
then
II II II
I, 1 0
II II
10 PCS.
= 0.10
kg
*If the sample weight is less than 0.1% of scale capacity, m will be displayed. Please place q more samples, /-L-Y then depress (-<:;*) key again. 2.Place EX. items 500 PCS. to be count. 1 II
60.00kg
x 0.1% = 0.06 I
kg (6Og) I
5 'lo;
m
3.Remove key
items
'cq mode.
to release
tare
and place kg kg
weight,,
n
= 1.00 =lO.OO
II
key to indicate
b
n
1
w5Ea ,mim
1.
"
Olall
ll
A u LI
0.
Orall
-II II
2.Enter ,Ex.
date 14.Nov.89
by numeric
key
118
II
II
* Enter data in order YY.MM.DD. * Display flashes for 3.Depress EEI time Ex. by numeric 12:34 key. key then
I( confirmation. enter 1, II
of
12.3
., for confirmation.
l.Place
10.00
kg weigh.t.
2.Depress
,$JL
key.
3.Depress
key.
II II
0.
I,
Omn
II
LJ
NOTE : Weighing Weighing available. conversion conversion "lb" '*g" to "kg" or to "oz","dwt" "kg" or to "lb" are available. vise versa are
8715 while
keep
II IIU n 1
II
II La 1
* Select
appropriate
weighing
1, 1)
II 0. 0 -'2
II I\
II
5.Enter numeric
scale key.
capacity
by
II II
0.0
,I
il
21 6.Depress displayed,
0
#
key.
CAL is key. on
II C
"
II
"
II
depress
II L
* Please make sure that nothing has been placed the scale. 7.CAL SP is displayed. _ _ the Place value
the& of 11
~ S
weight,
* We recommend to use capacity weight for the calibration to have correct scale accuracy. S.Completed.
0
#
key.
capacity capacity
must
be set
within
the
following
range.
= 10000 or less. Min. graduation (scale interval) t For example, if the min. increment is "2", you can set the scale capacity up to the "20000". But the higher display resolution may result flickering display or in-correct weight display in some case. c If you don't have the you can use any known (see item,7) - The minimum graduation capacity weight weight in stead must be following for calibration, of capacity weight. value.
22
8.
SPEC
l-There
LIST
are 2 ways to access the specification keep depressing changeover. @ code key. which are
* Depress
@@@while
a specification changeover access with user's changeable function. to 09 are available. while keep depressing
@xix3 This is a specification changeover related with the W & M regulation Spec.10 to 19 are available. 2.All the some of in some specification data them are available case. consists of in combination
-) ' key. 0 access code which for each country. binary another
are
4 digits with
3.When above code is accessed, display and it's data (4 digits) reciprocally are set at the factory when shipping.
Spec. 4.Data
Data keys.
of
Spec.
00
construction 00 ---
SPEC.
0 1 2 3
5.Useable @
keys. & @ --------Data Skip Skip entry.( Spec. back only No. Spec. end. Spec. "0000" No. are standard spec. data @ & @ set. & data set. are available )
6.The spec. data marked below when shipped. "Not used" should be set to
0 0
#
----------__-
Program
always.
23
Bit
2 funcNega.
Bit
1 weighing.
Bit
weight entry.
Time
print.
used
Not
used
used
Not
used
YY --MM ---
Year Month
0001
: 1 min.
1000 1001
: 8 min. : 9 min.
1100 1101
: 12 min. : 13 min.
Bit Not
3 used
Bit Not
2 used
Bit
Bit
Not used
Not used
;PEC. Tare during 13 zero tracking. : Yes 0000 Y : No ;PEC. Manual tare 14 clear. 0 : Yes @$O 1 : No ;PEC. Scale start 15 range 200 IR. 0 : No OOCJO1 : Yes ;PEC. Auto Tare 16 0 : No ~OQQCJ : Yes 0 Clear
Scale
start range.
limit.
0 : Yes 1 : No
When Gross wei- Zero -ght is below 0 0 : Minus 1 : Blank Digital 0 : Yes 0:No total. sign tare.
condition 21 d. ld.
;PEC. Decimal point. 17 : Comma cgc$ Y : Period ;PEC. 18 Not 0~0~00 ;PEC. Sensitivity 19 0000 : 3.46 0001 : 3.00 0010 : ,2.59 0011 : 2.55 0100 : 1.95 0101 : 1.69 0110 : 1.46 ::lOal 0111 : 1.27 Note: IR. FS. of ----------------used
20 d + 50 d Negative 0 : Yes 1 : No
print.
0 : No. 1 : Yes
exchange.
Not the 4.00 3.46 3.00 2.59 2.55 1.95 1.69 1.46
used to
Not used be used. 1000 1001 1010 1011 1100 1101 1110 1111 : : : : : : : : 1.09 0.95 0.82 0.71 0.61 0.53 0.46 0.40 -----------------
0 : Yes 1 : No
mV/V (I w w w 11 w "
25
9.
ERROR
Following is taken.
MESSAGE
error
LIST
will be appeared when in-correct operation.
message
Add (I
O Fll
weight displayed
total exceeded
exceeded 6
OF
weight
exceeded
scale
value operation,
entered is
II- - - - - - II
118 8 8 8 8 811
calibration
is
not
correct operation.
operation. calibration
Same
Please
Add II
x XII
weight
was less
than
(lSpT==Tq
When total
weight
is
minus.
NOTICE
To enter either the calibration or specification setting, the following procedure must be performed.
1. Remove the two screws and back panel (seeillustration). 2. Locate the calibration switch, and move it to the left (as shown).
TOP
Calibrate/Operate
Switch
DI-10 Rear view, back panel off. 3. Perform the calibration or specification code setting as needed. 4. Be sore to move the switch to the right before placing the unit back in service, to prevent unauthorized access. 5. Replace seal(s).
DIG1
GRAND
STANDARD
SPECIBICATIONS
REZERa
,9PECNO. 00 01 02 03 04 05 06 07 OS 09
REZEROl-4-2 SPEC NO. STD.SETTING 10 11 12 13 14 15 16 17 18 19 0000 0000 0000 0000 0000 0000 0000 00 0 0 0 0 0 0 10 01