SUMITOMO ELECTRIC INTERCONNECT PRODUCTS (M) SDN BHD

REVISION HISTORY LIST


DOCUMENT NO. DOCUMENT TITLE : :

HOT WATER RESISTANCE TEST

REV LEVEL

EFFECTIVE DATE

PURPOSE / REASON ( INCLUDING THE REVISION CONTENTS ) OF CHANGE

PERSONNEL PREPARED

same as final approval date

New release SNew release

YAP KW

PM-QMR-003/2 REV : 3

SUMITOMO ELECTRIC INTERCONNECT PRODUCTS (M) SDN BHD

WORK INSTRUCTION
Title :

Document No. :

WI - ED2 - 011

Rev. :

Page :

of

HOT WATER RESISTANCE TEST

PURPOSE This instruction outlines the testing method of Hot Water Resistance test.

SCOPE This work instruction applies to: - Thermoplastic or thermo set insulated automotive wire (PVC, PE, Fluoropolymer).

ASSOCIATED MATERIAL SAE J1127 STANDARD, SAE J1128 STANDARD, ISO 6722 STANDARD

DEFINITION Nil

WORK INSTRUCTION

1.

Outer appearance

1 2

1. 2. 3. 4. 5. 6.

DC power supply Hot plate Glass beaker with salt water Glass Beaker cover Thermometer Copper Electrode

SUMITOMO ELECTRIC INTERCONNECT PRODUCTS (M) SDN BHD

WORK INSTRUCTION
Title :

Document No. :

WI - ED2 - 011

Rev. :

Page :

of

HOT WATER RESISTANCE TEST

2.

Prepared 2.5m 0.1m test specimen with 25 mm of insulation shall be remove from each end of finished wire. Closely wind a minimum of 3 complete of the first test specimen around the mandrel specified below :

Conductor size (mm) a 2 2 < a 8 8< a

Mandrel size

Number of turns Minimum

5X Outside
cable Diameter Maximum

3 2 0.5

3.

Prepare salt water into glass beaker with mixing ratio 10 gram / liter of Nacl in distilled water. Heat up the salts water until reach temperature 85C 5C.

4.

Remove the specimen mandrel and immerse into the 85C 5C salts water. Connect one end of test specimen to the positive terminal of a 48 V DC power source. Connect the negative terminal to the copper electrode in the salts water.

5.

After immerse 7 days, disconnect the power source. Measure the insulation resistance, and calculate the "insulation Volume Resistivity" as below : Po = 2.725 LR log D

Po L R D d

is the "insulation volume Resistivity", expressed in O.mm is the immersed length of the test sample, expressed in mm is the measured insulation resistance, expressed in O is the outside cable diameter, in accordance with 5.3, expressed in mm is the conductor diameter, expressed in mm

log is log to the base 10


9

Results : The "Insulation Volume Resistivity" shall not less than 10 O.mm

6.

Step 2 ~ 5 mean completes one cycles. Repeat this procedure for a total of 5 cycles (35 days). After completed, remove the specimen from the salts water and allow it to cool to room temperature and make visual inspection of the insulation. .

7.

If no conductor found to be exposed by visual inspection, perform the Dielectric test as below condition.

7.1.

Dielectric test - Immerse the specimen into water containing 5% salts (Nacl) by weight at room temperature for 10 min. The specimen shall withstand the application of 1000 V rms at 50 to 60Hz between the conductor and the solution for 1 min without failure of the insulation.

8.

To start new test, replace the salt water inside the beaker and proceed step 2 to step 7

SUMITOMO ELECTRIC INTERCONNECT PRODUCTS (M) SDN BHD

WORK INSTRUCTION
Title :

Document No. :

WI - ED2 - 011

Rev. :

Page :

of

HOT WATER RESISTANCE TEST

APPENDIX Nil

RELEVANT RECORD Wire / Conductor/ Compound Check Requisition Form (WI-ED2-003/1)

EQUIPMENT REQUIRED a. b. Hot Plate Power supply (V DC).

SAFETY PRECAUTION 1) Do not touch the glass beaker and hot plate when testing in progress to prevent skin burn. 2) Do not touch the power supply positive and negative terminal during testing in progress to prevent electric shock.