Field Bkr Trip ESV/IV CLOSED & Trip oil Pr.LOW From EAST 86 T5 Gen.Bkr.

Off 86 UAT UATA Bkr Trip UATB Bkr Trip Gen.SEF 90% (64G2) Gen.SEF 95% (64G4) Gen.SEF 100% (64G3) Gen.&GT Overall differential(87GTU) Gen.Interturn differential(87G1) Gen.Differential Protection(87G) Emergency Hand Trip Reverse power Relay (32G2) To HP/LP Bypass cut in Field Bkr Trip RH Protection Tie Bkr Trip U1A Bus Tie Bkr Trip U1B Bus

Gen.Reverse Power -20Sec (32G1) Turbine Trips TURBINE TRIP RELAYS I & II Boiler MFT Gen.B/U Impedance (21G) Gen.Over voltage I&II (59G1&II) UAT A/B over current (50/51) UAT A Bucholz-II stage UAT B Bucholz-II stage UAT A/B Differential (87) Gen.-ve Seqnce II(46G2) Rotor E/F (64F2) Stator water flow V.low AVR Reg.Supply Fail Gen.Wdg/Oil Temp HiHi Stator water Cond. V.low AVR Manual channel Fail Loss of Excitation (40G1) Ext.Tr.Temp.V.Hi GT Restricted E/F GT B/U E/F protection GT Bucholz-II stage GT over flux I & II GT PRV Operated GT Bkr. struck up 50LBB GT Neutral O/C Dead Machine Relay GT OLTC Bucholz-II stage GT Neutral Over current (51NGT) Gen.B/U Impedance (21G) Gen.Tr.Over current (51GT) Gen.-ve Sequence (46G1) Gen.Pole slipping protection Gen.Tr.Busbar Protection GENERATOR CLASS C TRIP 86GB1 & 86GB2 Loss of Excitation(40G2) Loss of 5 Thy.Bridge Ex.Tr.Over current Instant Ex.Tr.Over current Delay-II 48V1 & 48V2 supply fail at AVR Gen.Rotor E/F (64GT) Rotor over voltage GENERATOR CLASS B TRIP 3 sec UAT A/B PRV Under Frequency (81)

GENERATOR CLASSA TRIP 86G1 & 86G2

T0 50LBB ckt of GT Bkr Transfer Bkr Trip Gen. Bkr Trip coils I&II

T0 FSSS leaving top 3 Bottom Mills Trip

ESV/IV CLOSED & Trip oil Pr.LOW

From EAST

86 T5

Gen.Bkr.Off

Gen Field Bkr Trip UATA Bkr Trip UATB Bkr Trip

Gen.Reverse Power -20Sec (32G1) Turbine Trips TURBINE TRIP RELAYS I & II Boiler MFT Gen.B/U Impedance (21G) Gen.Over voltage I&II (59G1&II) UAT A/B over current (50/51) UAT A Bucholz-II stage UAT B Bucholz-II stage UAT A/B Differential (87) Gen.-ve Seqnce II(46G2) Rotor E/F (64F2) Stator water flow V.low AVR Reg.Supply Fail Gen.Wdg/Oil Temp HiHi Stator water Cond. V.low AVR Manual channel Fail Loss of Excitation (40G1) Ext.Tr.Temp.V.Hi GT Restricted E/F GT B/U E/F protection GT Bucholz-II stage GT over flux I & II GT PRV Operated GT Bkr. struck up 50LBB GT Neutral O/C Dead Machine Relay GT OLTC Bucholz-II stage GT Neutral Over current (51NGT) Gen.B/U Impedance (21G) Gen.Tr.Over current (51GT) Gen.-ve Sequence (46G1) Gen.Pole slipping protection Gen.Tr.Busbar Protection GENERATOR CLASS C TRIP 86GB1 & 86GB2 Loss of Excitation(40G2) Loss of 5 Thy.Bridge Ex.Tr.Over current Instant Ex.Tr.Over current Delay-II 48V1 & 48V2 supply fail at AVR Gen.Rotor E/F (64GT) Rotor over voltage GENERATOR CLASS B TRIP 86 T4 3 sec UAT A/B PRV Under Frequency (81) Gen.SEF 90% (64G2) Gen.SEF 95% (64G4) Gen.SEF 100% (64G3) Gen.&GT Overall differential(87GTU) Gen.Interturn differential(87G1) Gen.Differential Protection(87G) Emergency Hand Trip Reverse power Relay (32G2)

Tie Bkr Trip U1A Bus Tie Bkr Trip U1B Bus

To HP/LP Bypass cut in Field Bkr Trip RH Protection

GENERATOR CLASSA TRIP 86G1 & 86G2

T0 50LBB ckt of GT Bkr Transfer Bkr Trip Gen. Bkr Trip coils I&II

T0 FSSS leaving top 3 Bottom Mills Trip