EC Type Examination Certificate


Equipment and Protective Systems Intended for Use in Potentially Explosive Atmospheres - Directive 94/9/EC EC-Type Examination Certificate Number

PTB 00 ATEX 3116


(4) (5) (6) (7) (8) Component: Manufacturer: Address: Terminal Box, Type Series 8125/1...-... and 8125/2...-... R. Stahl Schaltgerte GmbH Bergstrae 2, D-74653 Knzelsau

The construction of this component and any acceptable variation thereto is specified in the schedule to this type examination certificate. The Physikalisch Technische Bundesanstalt, notified body No. 0102 in accordance with Article 9 of the Council Directive 94/9/EC of 23 March 1994, certifies that this component has been found to comply with the Essential Health and Safety Requirements relating to the design and construction of equipment and protective systems intended for use in potentially explosive atmospheres, given in Annex II to the Directive. The results of the test are recorded in the confidential report No. PTB Ex 00-30039.

(9)

The Essential Health and Safety Requirements are met by compliance with EN 50 014:1997 EN 50 020:1994 EN 50 018:1994 EN 50 028:1987 EN 50 019:1994

(10) If the sign X is placed after the certificate number, it indicates special conditions for safe use of the equipment specified in the schedule to this certificate. (11) This EC Type Examination Certificate relates only to the design and construction of the specified component in accordance with Directive 94/9/EC. Further requirements of this directive apply to the manufacture and supply of this equipment. (12) The marking of the component shall include the following:

II 2 G EEx edm [ia] IIC T4/5/6 or EEx ia/ib IIA/IIB/IIC T6


Zertifizierungsstelle Explosionsschutz by order PTB (signature) Dr.-Ing. U. Engel Regierungsdirektor Braunschweig, 19 May 2000

Page 1/3

Uncertified Translation

Physikalisch-Technische Bundesanstalt
Braunschweig und Berlin

(13) (14)

Schedule
EC-Type Examination Certificate PTB 00 ATEX 3116

(15) Description of the component Terminal boxes, series 8125/1... and 8125/2..., made of sheet steel or stainless sheet steel, for fixed installation, with - separately certified - line-up terminals for non-intrinsically safe or separately certified - intrinsically safe circuits. The empty enclosures used are tested as components and specified in EC Type Examination Certificate PTB 00 ATEX 3111 U Type 8125/1... can additionally be equipped with - separately certified - isolating terminals and/or fuses. The marking with the identification symbol of the types of explosion protection is to be adapted to the components used. For intrinsically safe circuits, the box or area around the box is marked, e.g. with light blue colour. Technical data Rated voltage: max. 1100 V (depending on the operating voltage range of the terminals used) -50 C Tamb +55 C -50 C Tamb +75 C min. IP 54 to EN 60 529: 1991

Ambient temperature range, max. for type 8125/1...: Ambient temperature range, max. for type 8125/2...: Contact, foreign particles and ingress of water protection:

Rated current, number of conductors and conductor cross section are stipulated in the ascertained supplementary sheets. Note The terminal boxes are suitable for an ambient temperature range of -20 C to +40 C. The suitability for deviating ambient temperature ranges is visible by special marking. Only such separately certified - gaskets and - separately certified - built-in and built-on parts, suitable for these temperatures, are used. Additional instructions of the manufacturer have to be followed. Terminal boxes containing fuses and/or, beside the usual non-intrinsically safe circuits, intrinsically safe circuits, are provided with an additional marking. (16) Test report PTB Ex 00-30039 (17) Special conditions not applicable Page 2/3

Uncertified Translation

Physikalisch-Technische Bundesanstalt
Braunschweig und Berlin Schedule to EC-Type Examination Certificate PTB 00 ATEX 3116

(18) Essential Health and Safety Requirements The ingress protection - minimum IP 54 - is achieved only when using the tested gaskets, cable glands and stopping plugs properly.

Zertifizierungsstelle Explosionsschutz by order (signature) Dr.-Ing. U. Engel Regierungsdirektor

Braunschweig, 19 May 2000

Page 3/3

SUPPLEMENTARY SHEET 1
to EC Type Examination Certificate PTB 00 ATEX 3116
Fitting of terminal boxes Type 8125/1041 Max number of conductors
1)

depending on cross section and the permissible continuous current:

current / A 1,5
3 6 10 16 20 25 35 50 63 80 100 125 45 45 15 6 30 17 8

2,5

cross section / mm2 4 6 10 16

25

116 33 19 5 36 14 2 35 11 4

2)

29 13 5

48 15 6 7

4) 3)

45

30

19

11

max. number of terminals depending on the above mentioned enclosure size and the cross section resp. max permissible conductor cross section of the builtin terminals

Notes 1) Each incoming conductor and each internal connection wire is counted as a conductor. Bridges and earthing conductors are not counted. 2) additional conductors optional 3) to be specified by the manufacturer (including temperature rise test) 4) When applying the values of this table simultaneous factors or load factors to IEC 439 may be considered. Mixed equipment with circuits of different cross sections and currents is possible if the various values of the table are applied proportionally: Example: (general) cross section / mm 2,5 16 25 current / A 16 50 63 number of conductors 10 (of 30) 12 (of 48) 36 (of 90) total utilization = 33 % = 25 % = 40 % = 98 % < 100 %

\\SGTSRV05\D0\ABTL\SGZ\UEBERSET\8125\8125kl_2_Beibl_e.doc

SUPPLEMENTARY SHEET 2
to EC Type Examination Certificate PTB 00 ATEX 3116
Fitting of terminal boxes Type 8125/1051 Max number of conductors
1)

depending on cross section and the permissible continuous current:

current / A 1,5
3 6 10 16 20 25 35 50 63 80 100 125 75 51 17 7 34 19 9

2,5

cross section / mm2 4 6 10 16

25

132 38 21 6 41 16 2 40 13 4

2)

33 15 6

55 17 7 12

4) 3)

75

50

19

18

15

max. number of terminals depending on the above mentioned enclosure size and the cross section resp. max permissible conductor cross section of the builtin terminals

Notes 1) Each incoming conductor and each internal connection wire is counted as a conductor. Bridges and earthing conductors are not counted. 2) additional conductors optional 3) to be specified by the manufacturer (including temperature rise test) 4) When applying the values of this table simultaneous factors or load factors to IEC 439 may be considered. Mixed equipment with circuits of different cross sections and currents is possible if the various values of the table are applied proportionally: Example: (general) cross section / mm 2,5 16 25 current / A 16 50 63 number of conductors 10 (of 30) 12 (of 48) 36 (of 90) total utilization = 33 % = 25 % = 40 % = 98 % < 100 %

\\SGTSRV05\D0\ABTL\SGZ\UEBERSET\8125\8125kl_2_Beibl_e.doc

SUPPLEMENTARY SHEET 3
to EC Type Examination Certificate PTB 00 ATEX 3116
Fitting of terminal boxes Type 8125/1061 Max number of conductors
1)

depending on cross section and the permissible continuous current:

current / A 1,5
3 6 10 16 20 25 35 50 63 80 100 125 160 105 54 18 7 36 21 10

2,5

cross section / mm2 4 6 10 16

25

35

140 40 23 6 44 17 2 43 14 4

2)

35 16 6

58 18 7

65 17 7 10

4) 3)

105

75

38

26

21

17

max. number of terminals depending on the above mentioned enclosure size and the cross section resp. max permissible conductor cross section of the builtin terminals

Notes 1) Each incoming conductor and each internal connection wire is counted as a conductor. Bridges and earthing conductors are not counted. 2) additional conductors optional 3) to be specified by the manufacturer (including temperature rise test) 4) When applying the values of this table simultaneous factors or load factors to IEC 439 may be considered. Mixed equipment with circuits of different cross sections and currents is possible if the various values of the table are applied proportionally: Example: (general) cross section / mm 2,5 16 25 current / A 16 50 63 number of conductors 10 (of 30) 12 (of 48) 36 (of 90) total utilization = 33 % = 25 % = 40 % = 98 % < 100 %

\\SGTSRV05\D0\ABTL\SGZ\UEBERSET\8125\8125kl_2_Beibl_e.doc

SUPPLEMENTARY SHEET 4
to EC Type Examination Certificate PTB 00 ATEX 3116
Fitting of terminal boxes Type 8125/1063 Max number of conductors
1)

depending on cross section and the permissible continuous current:

current / A 1,5
3 6 10 16 20 25 35 50 63 80 100 125 160 105 71 24 10 47 27 13

2,5

cross section / mm2 4 6 10 16

25

35

183 53 30 8 58 22 3 56 18 6

2)

46 21 8

76 24 10

86 22 9 10

4) 3)

105

75

38

26

21

17

max. number of terminals depending on the above mentioned enclosure size and the cross section resp. max permissible conductor cross section of the builtin terminals

Notes 1) Each incoming conductor and each internal connection wire is counted as a conductor. Bridges and earthing conductors are not counted. 2) additional conductors optional 3) to be specified by the manufacturer (including temperature rise test) 4) When applying the values of this table simultaneous factors or load factors to IEC 439 may be considered. Mixed equipment with circuits of different cross sections and currents is possible if the various values of the table are applied proportionally: Example: (general) cross section / mm 2,5 16 25 current / A 16 50 63 number of conductors 10 (of 30) 12 (of 48) 36 (of 90) total utilization = 33 % = 25 % = 40 % = 98 % < 100 %

\\SGTSRV05\D0\ABTL\SGZ\UEBERSET\8125\8125kl_2_Beibl_e.doc

SUPPLEMENTARY SHEET 5
to EC Type Examination Certificate PTB 00 ATEX 3116
Fitting of terminal boxes Type 8125/1071 Max number of conductors
1)

depending on cross section and the permissible continuous current:

current / A 1,5
3 6 10 16 20 25 35 50 63 80 100 125 160 175 56 19 8 37 22 10

2,5

cross section / mm2 4 6 10 16

25

35

146 42 24 7 46 18 2 45 14 5

2)

37 17 6

61 19 8

68 18 7 10

4) 3)

175

112

57

41

33

27

max. Klemmenanzahl in Abhngigkeit von oben genannter Gehusegre und dem Querschnitt bzw. dem max. zul. Leiterquerschnitt der eingebauten Klemmen

Notes 1) Each incoming conductor and each internal connection wire is counted as a conductor. Bridges and earthing conductors are not counted. 2) additional conductors optional 3) to be specified by the manufacturer (including temperature rise test) 4) When applying the values of this table simultaneous factors or load factors to IEC 439 may be considered. Mixed equipment with circuits of different cross sections and currents is possible if the various values of the table are applied proportionally: Example: (general) cross section / mm 2,5 16 25 current / A 16 50 63 number of conductors 10 (of 30) 12 (of 48) 36 (of 90) total utilization = 33 % = 25 % = 40 % = 98 % < 100 %

\\SGTSRV05\D0\ABTL\SGZ\UEBERSET\8125\8125kl_2_Beibl_e.doc

SUPPLEMENTARY SHEET 6
to EC Type Examination Certificate PTB 00 ATEX 3116
Fitting of terminal boxes Type 8125/1073 Max number of conductors
1)

depending on cross section and the permissible continuous current:

current / A 1,5
3 6 10 16 20 25 35 50 63 80 100 125 160 200 225 250 175 175 112 72 24 10 48 28 13 187 54 30 9

2,5

cross section / mm2 6 10 16 25

35

50

70

59 23 3

2) 57 18 6 47 22 8

78 24 10

88 23 9

23 8

20 7 2 7

4) 3)

57

41

33

27

10

max. number of terminals depending on the above mentioned enclosure size and the cross section resp. max permissible conductor cross section of the built-in terminals

Notes 1) Each incoming conductor and each internal connection wire is counted as a conductor. Bridges and earthing conductors are not counted. 2) additional conductors optional 3) to be specified by the manufacturer (including temperature rise test) 4) When applying the values of this table simultaneous factors or load factors to IEC 439 may be considered. Mixed equipment with circuits of different cross sections and currents is possible if the various values of the table are applied proportionally: Example: (general) cross section / mm 2,5 16 25 current / A 16 50 63 number of conductors 10 (of 30) 12 (of 48) 36 (of 90) total utilization = 33 % = 25 % = 40 % = 98 % < 100 %

\\SGTSRV05\D0\ABTL\SGZ\UEBERSET\8125\8125kl_2_Beibl_e.doc

SUPPLEMENTARY SHEET 7
to EC Type Examination Certificate PTB 00 ATEX 3116
Fitting of terminal boxes Type 8125/1075 Max number of conductors
1)

depending on cross section and the permissible continuous current:

current / A 1,5
3 6 10 16 20 25 35 50 63 80 100 125 160 200 225 250 175 175 112 83 28 11 55 32 15 215 62 35 10

2,5

cross section / mm2 6 10 16 25

35

50

70

68 26 4

66 21 7

2) 54 25 9 90 28 12

101 26 10

27 9

23 8 3 7

4) 3)

57

41

33

27

10

max. number of terminals depending on the above mentioned enclosure size and the cross section resp. max permissible conductor cross section of the built-in terminals

Notes 1) Each incoming conductor and each internal connection wire is counted as a conductor. Bridges and earthing conductors are not counted. 2) additional conductors optional 3) to be specified by the manufacturer (including temperature rise test) 4) When applying the values of this table simultaneous factors or load factors to IEC 439 may be considered. Mixed equipment with circuits of different cross sections and currents is possible if the various values of the table are applied proportionally: Example: (general) cross section / mm 2,5 16 25 current / A 16 50 63 number of conductors 10 (of 30) 12 (of 48) 36 (of 90) total utilization = 33 % = 25 % = 40 % = 98 % < 100 %

\\SGTSRV05\D0\ABTL\SGZ\UEBERSET\8125\8125kl_2_Beibl_e.doc

SUPPLEMENTARY SHEET 8
to EC Type Examination Certificate PTB 00 ATEX 3116
Fitting of terminal boxes Type 8125/1081 and Type 8125/1201 Max number of conductors
1)

depending on cross section and the permissible continuous current:

current / A 1,5
3 6 10 16 20 25 35 50 63 80 100 125 160 392 77 26 11 51 30 14

2,5

cross section / mm2 4 6 10 16

25

35

199 58 32 9 63 24 3 61 20 6

2)

50 23 9

83 26 11

93 24 10 22

4) 3)

392

224

126

82

66

54

max. number of terminals depending on the above mentioned enclosure size and the cross section resp. max permissible conductor cross section of the builtin terminals

Notes 1) Each incoming conductor and each internal connection wire is counted as a conductor. Bridges and earthing conductors are not counted. 2) additional conductors optional 3) to be specified by the manufacturer (including temperature rise test) 4) When applying the values of this table simultaneous factors or load factors to IEC 439 may be considered. Mixed equipment with circuits of different cross sections and currents is possible if the various values of the table are applied proportionally: Example: (general) cross section / mm 2,5 16 25 current / A 16 50 63 number of conductors 10 (of 30) 12 (of 48) 36 (of 90) total utilization = 33 % = 25 % = 40 % = 98 % < 100 %

\\SGTSRV05\D0\ABTL\SGZ\UEBERSET\8125\8125kl_2_Beibl_e.doc

SUPPLEMENTARY SHEET 9
to EC Type Examination Certificate PTB 00 ATEX 3116
Fitting of terminal boxes Type 8125/1083 and Type 8125/1203 Max number of conductors
1)

depending on cross section and the permissible continuous current:

current / A 1,5
3 6 10 16 20 25 35 50 63 80 100 125 160 200 225 250 392 392 224 94 32 13 62 36 17 243 70 40 11

2,5

cross section / mm2 6 10 16 25

35

50

70

77 30 4

2) 74 24 8 62 28 11

102 32 13

114 30 12

30 10

27 9 3 15

4) 3)

126

82

66

54

22

15

max. number of terminals depending on the above mentioned enclosure size and the cross section resp. max permissible conductor cross section of the built-in terminals

Notes 1) Each incoming conductor and each internal connection wire is counted as a conductor. Bridges and earthing conductors are not counted. 2) additional conductors optional 3) to be specified by the manufacturer (including temperature rise test) 4) When applying the values of this table simultaneous factors or load factors to IEC 439 may be considered. Mixed equipment with circuits of different cross sections and currents is possible if the various values of the table are applied proportionally: Example: (general) cross section / mm 2,5 16 25 current / A 16 50 63 number of conductors 10 (of 30) 12 (of 48) 36 (of 90) total utilization = 33 % = 25 % = 40 % = 98 % < 100 %

\\SGTSRV05\D0\ABTL\SGZ\UEBERSET\8125\8125kl_2_Beibl_e.doc

S U P P L E M E N T A R Y S H E E T 10
to EC Type Examination Certificate PTB 00 ATEX 3116
Fitting of terminal boxes Type 8125/1085 and Type 8125/1205 Max number of conductors
1)

depending on cross section and the permissible continuous current:

current / A 1,5
3 6 10 16 20 25 35 50 63 80 100 125 160 200 225 250 392 392 224 105 36 15 70 41 19 272 79 45 13

2,5

cross section / mm2 6 10 16 25

35

50

70

86 33 5

2) 84 27 9 69 32 12

114 36 15

128 33 13

34 11

30 10 4 15

4) 3)

126

82

66

54

22

15

max. number of terminals depending on the above mentioned enclosure size and the cross section resp. max permissible conductor cross section of the built-in terminals

Notes 1) Each incoming conductor and each internal connection wire is counted as a conductor. Bridges and earthing conductors are not counted. 2) additional conductors optional 3) to be specified by the manufacturer (including temperature rise test) 4) When applying the values of this table simultaneous factors or load factors to IEC 439 may be considered. Mixed equipment with circuits of different cross sections and currents is possible if the various values of the table are applied proportionally: Example: (general) cross section / mm 2,5 16 25 current / A 16 50 63 number of conductors 10 (of 30) 12 (of 48) 36 (of 90) total utilization = 33 % = 25 % = 40 % = 98 % < 100 %

\\SGTSRV05\D0\ABTL\SGZ\UEBERSET\8125\8125kl_2_Beibl_e.doc

S U P P L E M E N T A R Y S H E E T 11
to EC Type Examination Certificate PTB 00 ATEX 3116
Fitting of terminal boxes Type 8125/1091 Max number of conductors
1)

depending on cross section and the permissible continuous current:

current / A 1,5
3 6 10 16 20 25 35 50 63 80 100 125 160 819 89 30 12 59 34 16

2,5

cross section / mm2 4 6 10 16

25

35

231 67 38 11 73 28 4 71 23 7

2)

59 27 10

97 30 13

108 28 11 66

4) 3)

819

560

294

205

138

114

max. number of terminals depending on the above mentioned enclosure size and the cross section resp. max permissible conductor cross section of the builtin terminals

Notes 1) Each incoming conductor and each internal connection wire is counted as a conductor. Bridges and earthing conductors are not counted. 2) additional conductors optional 3) to be specified by the manufacturer (including temperature rise test) 4) When applying the values of this table simultaneous factors or load factors to IEC 439 may be considered. Mixed equipment with circuits of different cross sections and currents is possible if the various values of the table are applied proportionally: Example: (general) cross section / mm 2,5 16 25 current / A 16 50 63 number of conductors 10 (of 30) 12 (of 48) 36 (of 90) total utilization = 33 % = 25 % = 40 % = 98 % < 100 %

\\SGTSRV05\D0\ABTL\SGZ\UEBERSET\8125\8125kl_2_Beibl_e.doc

S U P P L E M E N T A R Y S H E E T 12
to EC Type Examination Certificate PTB 00 ATEX 3116
Fitting of terminal boxes Type Typ 8125/1093 Max number of conductors
1)

depending on cross section and the permissible continuous current:

current

cross section / mm2


1,5 2,5 4 6 10 16 25 35 50 70 95 120 150 185 240 300

A
3 6 10 16 20 25 35 50 63 80 100 125 160 200 225 250 315 400 500

105 36 15

70 41 19

272 79 45 13 86 33 5 84 27 9

69 32 12

2) 114 36 15 128 34 13

34 11

30 10 4

26 15 8

80 31 19 4 40 11 24 5

16 2 7

48 9 7

4) 3)

819

819

560

294

205

138

114

66

32

32

max. number of terminals depending on the above mentioned enclosure size and the cross section resp. max permissible conductor cross section of the built-in terminals

Notes 1) Each incoming conductor and each internal connection wire is counted as a conductor. Bridges and earthing conductors are not counted. 2) additional conductors optional 3) to be specified by the manufacturer (including temperature rise test) 4) When applying the values of this table simultaneous factors or load factors to IEC 439 may be considered. Mixed equipment with circuits of different cross sections and currents is possible if the various values of the table are applied proportionally: Example: (general) cross section / mm 2,5 16 25 current / A 16 50 63 number of conductors 10 (of 30) 12 (of 48) 36 (of 90) total
\\SGTSRV05\D0\ABTL\SGZ\UEBERSET\8125\8125kl_2_Beibl_e.doc

utilization = 33 % = 25 % = 40 % = 98 % < 100 %

S U P P L E M E N T A R Y S H E E T 13
to EC Type Examination Certificate PTB 00 ATEX 3116
Fitting of terminal boxes Type 8125/1095 Max number of conductors
1)

depending on cross section and the permissible continuous current:

current

cross section / mm2


1,5 2,5 4 6 10 16 25 35 50 70 95 120 150 185 240 300

A
3 6 10 16 20 25 35 50 63 80 100 125 160 200 225 250 315 400 500

116 40 16

77 45 21

300 87 49 14 95 37 5 92 30 10

76 35 13

2) 126 39 17 141 37 15

37 13

33 12 4

29 16 8

89 35 21 4 44 12 26 5

18 2 7

53 10 7

4) 3)

819

819

560

294

205

138

114

66

32

32

max. number of terminals depending on the above mentioned enclosure size and the cross section resp. max permissible conductor cross section of the built-in terminals

Notes 1) Each incoming conductor and each internal connection wire is counted as a conductor. Bridges and earthing conductors are not counted. 2) additional conductors optional 3) to be specified by the manufacturer (including temperature rise test) 4) When applying the values of this table simultaneous factors or load factors to IEC 439 may be considered. Mixed equipment with circuits of different cross sections and currents is possible if the various values of the table are applied proportionally: Example: (general) cross section / mm 2,5 16 25 current / A 16 50 63 number of conductors 10 (of 30) 12 (of 48) 36 (of 90) total
\\SGTSRV05\D0\ABTL\SGZ\UEBERSET\8125\8125kl_2_Beibl_e.doc

utilization = 33 % = 25 % = 40 % = 98 % < 100 %

S U P P L E M E N T A R Y S H E E T 14
to EC Type Examination Certificate PTB 00 ATEX 3116
Fitting of terminal boxes Type 8125/1076 Max number of conductors
1)

depending on cross section and the permissible continuous current:

current / A 1,5
3 6 10 16 20 25 35 50 63 80 100 125 160 200 225 250 175 175 112 94 32 13 62 36 17 242 70 40 11

2,5

cross section / mm2 6 10 16 25

35

50

70

77 30 4

2) 74 24 8 62 28 11

102 32 13

114 30 12

30 10

27 9 3 7

4) 3)

57

41

33

27

10

max. number of terminals depending on the above mentioned enclosure size and the cross section resp. max permissible conductor cross section of the built-in terminals

Notes 1) Each incoming conductor and each internal connection wire is counted as a conductor. Bridges and earthing conductors are not counted. 2) additional conductors optional 3) to be specified by the manufacturer (including temperature rise test) 4) When applying the values of this table simultaneous factors or load factors to IEC 439 may be considered. Mixed equipment with circuits of different cross sections and currents is possible if the various values of the table are applied proportionally: Example: (general) cross section / mm 2,5 16 25 current / A 16 50 63 number of conductors 10 (of 30) 12 (of 48) 36 (of 90) total utilization = 33 % = 25 % = 40 % = 98 % < 100 %

\\SGTSRV05\D0\ABTL\SGZ\UEBERSET\8125\8125kl_2_Beibl_e.doc

S U P P L E M E N T A R Y S H E E T 15
to EC Type Examination Certificate PTB 00 ATEX 3116
Fitting of terminal boxes Type 8125/1106 and Type 8125/1107 Max number of conductors
1)

depending on cross section and the permissible continuous current:

current / A 1,5
3 6 10 16 20 25 35 50 63 80 100 125 160 200 225 250 245 245 168 104 35 14 69 40 19 268 78 44 13

2,5

cross section / mm2 6 10 16 25

35

50

70

85 33 4

2) 82 27 9 68 31 12

112 35 15

126 33 13

33 11

29 10 4 9

4) 3)

84

52

40

34

22

max. number of terminals depending on the above mentioned enclosure size and the cross section resp. max permissible conductor cross section of the built-in terminals

Notes 1) Each incoming conductor and each internal connection wire is counted as a conductor. Bridges and earthing conductors are not counted. 2) additional conductors optional 3) to be specified by the manufacturer (including temperature rise test) 4) When applying the values of this table simultaneous factors or load factors to IEC 439 may be considered. Mixed equipment with circuits of different cross sections and currents is possible if the various values of the table are applied proportionally: Example: (general) cross section / mm 2,5 16 25 current / A 16 50 63 number of conductors 10 (of 30) 12 (of 48) 36 (of 90) total utilization = 33 % = 25 % = 40 % = 98 % < 100 %

\\SGTSRV05\D0\ABTL\SGZ\UEBERSET\8125\8125kl_2_Beibl_e.doc

S U P P L E M E N T A R Y S H E E T 16
to EC Type Examination Certificate PTB 00 ATEX 3116
Fitting of terminal boxes Type 8125/1086, Type 8125/1206, Type 8125/1087 and Type 8125/1207 Max number of conductors
1)

depending on cross section and the permissible continuous current:

current / A 1,5
3 6 10 16 20 25 35 50 63 80 100 125 160 200 225 250 392 392 224 117 40 16 77 45 21 302 87 49 14

2,5

cross section / mm2 6 10 16 25

35

50

70

95 37 5

2) 93 30 10 77 35 13

126 39 17

142 37 15

38 13

33 12 4 15

4) 3)

126

82

66

54

22

15

max. number of terminals depending on the above mentioned enclosure size and the cross section resp. max permissible conductor cross section of the built-in terminals

Notes 1) Each incoming conductor and each internal connection wire is counted as a conductor. Bridges and earthing conductors are not counted. 2) additional conductors optional 3) to be specified by the manufacturer (including temperature rise test) 4) When applying the values of this table simultaneous factors or load factors to IEC 439 may be considered. Mixed equipment with circuits of different cross sections and currents is possible if the various values of the table are applied proportionally: Example: (general) cross section / mm 2,5 16 25 current / A 16 50 63 number of conductors 10 (of 30) 12 (of 48) 36 (of 90) total utilization = 33 % = 25 % = 40 % = 98 % < 100 %

\\SGTSRV05\D0\ABTL\SGZ\UEBERSET\8125\8125kl_2_Beibl_e.doc

S U P P L E M E N T A R Y S H E E T 17
to EC Type Examination Certificate PTB 00 ATEX 3116
Fitting of terminal boxes Type 8125/1256 and Type 8125/1257 Max number of conductors
1)

depending on cross section and the permissible continuous current:

current / A 1,5
3 6 10 16 20 25 35 50 63 80 100 125 160 200 225 250 322 322 224 112 38 16 74 43 20 288 83 47 14

2,5

cross section / mm2 6 10 16 25

35

50

70

91 36 5

2) 89 29 9 73 34 13

121 38 16

135 36 14

36 12

32 11 4 12

4) 3)

126

82

66

44

22

15

max. number of terminals depending on the above mentioned enclosure size and the cross section resp. max permissible conductor cross section of the built-in terminals

Notes 1) Each incoming conductor and each internal connection wire is counted as a conductor. Bridges and earthing conductors are not counted. 2) additional conductors optional 3) to be specified by the manufacturer (including temperature rise test) 4) When applying the values of this table simultaneous factors or load factors to IEC 439 may be considered. Mixed equipment with circuits of different cross sections and currents is possible if the various values of the table are applied proportionally: Example: (general) cross section / mm 2,5 16 25 current / A 16 50 63 number of conductors 10 (of 30) 12 (of 48) 36 (of 90) total utilization = 33 % = 25 % = 40 % = 98 % < 100 %

\\SGTSRV05\D0\ABTL\SGZ\UEBERSET\8125\8125kl_2_Beibl_e.doc

S U P P L E M E N T A R Y S H E E T 18
to EC Type Examination Certificate PTB 00 ATEX 3116
Fitting of terminal boxes Type 8125/1356 and Type 8125/1357 Max number of conductors
1)

depending on cross section and the permissible continuous current:

current

cross section / mm2


1,5 2,5 4 6 10 16 25 35 50 70 95 120 150 185 240 300

A
3 6 10 16 20 25 35 50 63 80 100 125 160 200 225 250 315 400 500

115 39 16

76 44 21

297 86 49 14 94 37 5 91 30 10

76 35 13

2) 125 39 16 140 37 15

37 13

33 11 4

28 16 8

88 34 21 4 43 12 26 5

18 2 6

52 10 6

4) 3)

414

414

304

171

110

88

44

36

20

12

max. number of terminals depending on the above mentioned enclosure size and the cross section resp. max permissible conductor cross section of the built-in terminals

Notes 1) Each incoming conductor and each internal connection wire is counted as a conductor. Bridges and earthing conductors are not counted. 2) additional conductors optional 3) to be specified by the manufacturer (including temperature rise test) 4) When applying the values of this table simultaneous factors or load factors to IEC 439 may be considered. Mixed equipment with circuits of different cross sections and currents is possible if the various values of the table are applied proportionally: Example: (general) cross section / mm 2,5 16 25 current / A 16 50 63 number of conductors 10 (of 30) 12 (of 48) 36 (of 90) total
\\SGTSRV05\D0\ABTL\SGZ\UEBERSET\8125\8125kl_2_Beibl_e.doc

utilization = 33 % = 25 % = 40 % = 98 % < 100 %

S U P P L E M E N T A R Y S H E E T 19
to EC Type Examination Certificate PTB 00 ATEX 3116
Fitting of terminal boxes Type 8125/1306 and Type 8125/1307 Max number of conductors
1)

depending on cross section and the permissible continuous current:

current

cross section / mm2


1,5 2,5 4 6 10 16 25 35 50 70 95 120 150 185 240 300

A
3 6 10 16 20 25 35 50 63 80 100 125 160 200 225 250 315 400 500

123 42 17

82 48 22

317 92 52 15 100 39 5 97 32 10

81 37 14

2) 133 41 18 149 39 16

40 13

35 12 4

30 17 9

94 37 22 4 46 13 28 6

19 2 7

56 11 7

4) 3)

532

532

336

210

123

99

74

44

20

20

max. number of terminals depending on the above mentioned enclosure size and the cross section resp. max permissible conductor cross section of the built-in terminals

Notes 1) Each incoming conductor and each internal connection wire is counted as a conductor. Bridges and earthing conductors are not counted. 2) additional conductors optional 3) to be specified by the manufacturer (including temperature rise test) 4) When applying the values of this table simultaneous factors or load factors to IEC 439 may be considered. Mixed equipment with circuits of different cross sections and currents is possible if the various values of the table are applied proportionally: Example: (general) cross section / mm 2,5 16 25 current / A 16 50 63 number of conductors 10 (of 30) 12 (of 48) 36 (of 90) total
\\SGTSRV05\D0\ABTL\SGZ\UEBERSET\8125\8125kl_2_Beibl_e.doc

utilization = 33 % = 25 % = 40 % = 98 % < 100 %

S U P P L E M E N T A R Y S H E E T 20
to EC Type Examination Certificate PTB 00 ATEX 3116
Fitting of terminal boxes Type 8125/1585 Max number of conductors
1)

depending on cross section and the permissible continuous current:

current

cross section / mm2


1,5 2,5 4 6 10 16 25 35 50 70 95 120 150 185 240 300

A
3 6 10 16 20 25 35 50 63 80 100 125 160 200 225 250 315 400 500

131 45 18

87 51 24

340 98 56 16 107 42 6 104 34 11

86 40 15

2) 142 44 19 2 160 42 17

42 14

37 13 5

32 18 10

100 39 24 5 50 14 30 6

20 3 11

60 12 11

4) 3)

957

957

609

325

252

153

126

68

23

23

14

14

11

11

max. number of terminals depending on the above mentioned enclosure size and the cross section resp. max permissible conductor cross section of the built-in terminals

Notes 1) Each incoming conductor and each internal connection wire is counted as a conductor. Bridges and earthing conductors are not counted. 2) additional conductors optional 3) to be specified by the manufacturer (including temperature rise test) 4) When applying the values of this table simultaneous factors or load factors to IEC 439 may be considered. Mixed equipment with circuits of different cross sections and currents is possible if the various values of the table are applied proportionally: Example: (general) cross section / mm 2,5 16 25 current / A 16 50 63 number of conductors 10 (of 30) 12 (of 48) 36 (of 90) total
\\SGTSRV05\D0\ABTL\SGZ\UEBERSET\8125\8125kl_2_Beibl_e.doc

utilization = 33 % = 25 % = 40 % = 98 % < 100 %

S U P P L E M E N T A R Y S H E E T 21
to EC Type Examination Certificate PTB 00 ATEX 3116
Fitting of terminal boxes Type 8125/1586 Max number of conductors
1)

depending on cross section and the permissible continuous current:

current

cross section / mm2


1,5 2,5 4 6 10 16 25 35 50 70 95 120 150 185 240 300

A
3 6 10 16 20 25 35 50 63 80 100 125 160 200 225 250 315 400 500

143 49 20

95 55 26

369 107 61 18 117 46 6 113 37 12

94 44 16

2) 155 48 21 2 173 46 18

46 16

41 14 5

35 20 10

109 43 26 5 54 15 32 7

22 3 11

65 13 11

4) 3)

957

957

609

325

252

153

126

68

23

23

14

14

11

11

max. number of terminals depending on the above mentioned enclosure size and the cross section resp. max permissible conductor cross section of the built-in terminals

Notes 1) Each incoming conductor and each internal connection wire is counted as a conductor. Bridges and earthing conductors are not counted. 2) additional conductors optional 3) to be specified by the manufacturer (including temperature rise test) 4) When applying the values of this table simultaneous factors or load factors to IEC 439 may be considered. Mixed equipment with circuits of different cross sections and currents is possible if the various values of the table are applied proportionally: Example: (general) cross section / mm 2,5 16 25 current / A 16 50 63 number of conductors 10 (of 30) 12 (of 48) 36 (of 90) total
\\SGTSRV05\D0\ABTL\SGZ\UEBERSET\8125\8125kl_2_Beibl_e.doc

utilization = 33 % = 25 % = 40 % = 98 % < 100 %

S U P P L E M E N T A R Y S H E E T 22
to EC Type Examination Certificate PTB 00 ATEX 3116
Fitting of terminal boxes Type 8125/1096, Type 8125/1906, Type 8125/1097 and Type 8125/1907 Max number of conductors
1)

depending on cross section and the permissible continuous current:

current

cross section / mm2


1,5 2,5 4 6 10 16 25 35 50 70 95 120 150 185 240 300

A
3 6 10 16 20 25 35 50 63 80 100 125 160 200 225 250 315 400 500

127 43 18

84 49 23

328 95 54 16 104 40 6 101 33 11

83 39 15

2) 138 43 18 2 154 40 16

41 14

36 13 5

31 18 9

97 38 23 5 48 14 29 6

20 2 7

57 11 7

4) 3)

819

819

560

294

205

138

114

66

32

32

max. number of terminals depending on the above mentioned enclosure size and the cross section resp. max permissible conductor cross section of the built-in terminals

Notes 1) Each incoming conductor and each internal connection wire is counted as a conductor. Bridges and earthing conductors are not counted. 2) additional conductors optional 3) to be specified by the manufacturer (including temperature rise test) 4) When applying the values of this table simultaneous factors or load factors to IEC 439 may be considered. Mixed equipment with circuits of different cross sections and currents is possible if the various values of the table are applied proportionally: Example: (general) cross section / mm 2,5 16 25 current / A 16 50 63 number of conductors 10 (of 30) 12 (of 48) 36 (of 90) total
\\SGTSRV05\D0\ABTL\SGZ\UEBERSET\8125\8125kl_2_Beibl_e.doc

utilization = 33 % = 25 % = 40 % = 98 % < 100 %

S U P P L E M E N T A R Y S H E E T 23
to EC Type Examination Certificate PTB 00 ATEX 3116
Fitting of terminal boxes Type 8125/1916 and Type 8125/1917 Max number of conductors
1)

depending on cross section and the permissible continuous current:

current

cross section / mm2


1,5 2,5 4 6 10 16 25 35 50 70 95 120 150 185 240 300

A
3 6 10 16 20 25 35 50 63 80 100 125 160 200 225 250 315 400 500

170 58 24

113 66 31

438 127 72 21 138 54 8 135 44 15

111 52 20

2) 184 57 24 2 206 54 22

55 19

48 17 6

52 24 13

129 51 31 6 64 18 38 8

26 3 15

77 15 15

4) 3)

1770

1180 616

430

276

232

138

64

64

20

20

15

15

max. number of terminals depending on the above mentioned enclosure size and the cross section resp. max permissible conductor cross section of the built-in terminals

Notes 1) Each incoming conductor and each internal connection wire is counted as a conductor. Bridges and earthing conductors are not counted. 2) additional conductors optional 3) to be specified by the manufacturer (including temperature rise test) 4) When applying the values of this table simultaneous factors or load factors to IEC 439 may be considered. Mixed equipment with circuits of different cross sections and currents is possible if the various values of the table are applied proportionally: Example: (general) cross section / mm 2,5 16 25 current / A 16 50 63 number of conductors 10 (of 30) 12 (of 48) 36 (of 90) total
\\SGTSRV05\D0\ABTL\SGZ\UEBERSET\8125\8125kl_2_Beibl_e.doc

utilization = 33 % = 25 % = 40 % = 98 % < 100 %

S U P P L E M E N T A R Y S H E E T 24
to EC Type Examination Certificate PTB 00 ATEX 3116
Fitting of terminal boxes Type 8125/1913 Maximale Anzahl der Leiter 1) in Abhngigkeit vom Querschnitt und dem zulssigen Dauerstrom:

current

cross section / mm2


1,5 2,5 4 6 10 16 25 35 50 70 95 120 150 185 240 300

A
3 6 10 16 20 25 35 50 63 80 100 125 160 200 225 250 315 400 500

147 50 21

97 57 27

379 110 62 18

120 47 116 7 38 13

96 45 17

2) 159 50 178 21 47 2 19

47 16

42 15 5

36 21 11

112 44 27 5

56 16

33 7

23 3 15

66 13 15

4) 3)

1770

1180 616 430 276 232 138

64

64

20

20

15

15

max. number of terminals depending on the above mentioned enclosure size and the cross section resp. max permissible conductor cross section of the built-in terminals

Notes 1) Each incoming conductor and each internal connection wire is counted as a conductor. Bridges and earthing conductors are not counted. 2) additional conductors optional 3) to be specified by the manufacturer (including temperature rise test) 4) When applying the values of this table simultaneous factors or load factors to IEC 439 may be considered. Mixed equipment with circuits of different cross sections and currents is possible if the various values of the table are applied proportionally: Example: (general) cross section / mm 2,5 16 25 current / A 16 50 63 number of conductors 10 (of 30) 12 (of 48) 36 (of 90) total utilization = 33 % = 25 % = 40 % = 98 % < 100 %