CO2 sensor Type A2G-85, air2guide CO2


WIKA Datasheet A2G-85

Applications
The CO2 sensing system uses real time CO2 measurements to determine actual occupancy during the day. A system using the CO2 sensor adjusts outside air delivery to provide only the amount of ventilation needed, thus virtually eliminating 100% of excessive amount of outside air used in a building For the CO2 measurement, a "Non Dispersive InfraRed (NDIR)" technology with automatic self-calibration is used

Special features
Easy installation Maintenance-free Compact and robust design CO2 sensor air2guide CO2, Type A2G-85

Description
Wherever people are staying in rooms, the CO2 concentration is an evident indicator for the room quality. The higher the CO2 content, the worse the air quality. Design standards Per 2004/108/EC Electromagnetic compatibility Product safety: 2001/95/EC Product safety EMC: EN 60730-1:2002 Product safety: EN 60730-1:2002 Analog outputs 0 ... 10 V, analog output max. 10 mA Temperature dependency <0.2 % of the full scale value every 1.8 F Accuracy Typically 40 ppm + 4% of the measured value

Permissible temperature Ambient: + 32 ... +122 F Operation: + 32 ... +122 F, max. 85% rH, non-condensing Ingress protection IP 20 per EN 60529 / lEC 529 Weight approx. 2.9 lbs

WIKA Datasheet A2G-85 04/2011

Page 1 of 2
R

Standard features
CO2 sensor 0 ... 2000 ppm ( parts per million) Sensor functional principle: NDIR (non dispersive infrared) Housing Connection head: PC, 120 x 120 x 85 mm, with cover (crystalclear) Sensor tube: Steel, galvanized, length 11.89, 1.18 , incl. mounting flange Electrical connection PG gland M16 Supply voltage DC 15 ... 24 V (10 %) or AC 24 V (10 %) safety extra-low voltage (SELV) Power consumption max. 3 W / max. 6 VA

Options
LC display for indicating the measured values and parameter settings 3 LEDs for displaying the CO2 content 0 ... 750 ppm: Green LED is on = good 751 ... 1250 ppm: Yellow LED is on = moderate 1251 ... 2000 ppm: Red LED is on = poor

Dimensions in inches
4.7

Installation instructions
The instruments are supplied in an operational status. The instrument is already equipped with a 1.5 m long connection cable and there is no need to open it. If an opening of the cover becomes necessary, make sure that the case is hermetically sealed again afterwards. The mounting to the ventilation duct is made by means of the flange included (mounting screws are not included)
11.8

Mounting flange
2.95 1.18 0.69 1.77

3.55

Connection cable 5 feet

0.1

brown white yellow

Supply voltage +24 V Reference potential GND Output measured value CO2

Air velocity max. 1968 FPM


2.36

2011 WIKA Alexander Wiegand SE & Co. KG, all rights reserved. The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials.

Page 2 of 2

WIKA Datasheet A2G-85 04/2011


R

WIKA Instrument Corporation 1000 Wiegand Boulevard Lawrenceville, GA 30043 Tel (770) 513-8200 Toll-free 1-888-WIKA-USA Fax (770) 338-5118 E-Mail info@wika.com www.wika.com