Sei sulla pagina 1di 1

BOGE

Model

Flow capacity

DS 75
DS 95
DS 120
DS 140
DS 180

m3/min
7.58
9.50
12.00
14.00
18.00

m3/h
455
570
720
840
1080

cfm
268
335
424
494
636

DS 220

22.00

1320

777

DS 260
26.00 1560
DS 300
30.17 1810
DS 350
35.00 2100
DS 460
46.00 2760
DS 520
52.00 3120
DS 630
63.00 3780
DS 750
75.00 4500
DS 900
90.00 5400
DS 1200 120.00 7200
DS 1500 150.00 9000
DS 1800 180.00 10800

918
1065
1236
1624
1836
2225
2648
3178
4237
5297
6356

Max.
operating
pressure
bar
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14

0.130
0.170
0.240
0.140
0.180
0.260
0.160
0.230
0.230
0.200
0.260

Dimensions Weight
WxDxH

m3/h
2830
2830
2800
2800
4000

cfm
1664
1664
1646
1646
2352

mm
703x562x945
703x562x945
706x1046x1064
706x1046x1064
706x1046x1064

kg
83
83
145
145
155

kW
1.42
2.00
2.38
2.38
3.02

HP
1.93
2.72
3.42
3.42
4.11

2.28

3.41

4.64

G 2 1/2

7050

4145

806x1166x1316

230

1.885 2.19 2.98


2.465 2.41 3.28
3.480 3.06 4.16
2.030 3.14 4.27
2.610 3.54 4.81
3.770 4.64 6.31
2.320 5.73 7.79
3.335 7.63 10.38
3.335 8.92 12.13
2.900 12.35 16.80
3.770 15.96 21.71

4.47
5.27
6.26
6.26
7.46
9.92
11.32
16.26
19.26
25.64
31.04

6.08
7.17
8.51
8.51
10.15
13.49
15.40
22.11
26.19
34.87
42.21

G 2 1/2
G 2 1/2
G 2 1/2
DN 100
DN 100
DN 100
DN 150
DN 150
DN 150
DN 200
DN 200

7050
7050
7050
7050
7050
14100
14100
19000
19000
28500
28500

4145
4145
4145
4145
4145
8291
8291
11172
11172
16758
16758

806x1166x1316
806x1166x1316
806x1166x1316
1007x1245x1723
1007x1245x1723
1007x1657x1810
1007x1657x1810
1007x1657x1810
1007x1657x1807
1007x2257x2208
1007x2257x2208

240
245
250
470
490
580
670
690
830
1100
1190

14 0.090 1.305

1.68

Installed
power

Cooling air
requirement

Compressed
air connection
G 1 1/2
G 1 1/2
G2
G2
G2

Electr.
Pressure
power
differential
at full load consumption
bar psig
kW
HP
0.130 1.885 0.90 1.22
0.210 3.045 1.38 1.88
0.130 1.885 1.13 1.54
0.180 2.610 1.14 1.55
0.230 3.335 1.46 1.99

Conversion factors
According to DIN ISO 7183, refrigerant dryers are designed for 7 bar operating pressure, an ambient temperature of +25C and an inlet temperature of
+35C. For differing operating pressures and temperatures the following conversion factors should be used.
Ambient/cooling water temperature
Factor
Inlet temperature
Factor
Operating pressure
Factor
Pressure dew point
Factor

25
20
30
35
40
C
f1
0.94
0.88
0.82
1.00
1.06
35
C
30
40
45
50
1.00
f2
1.21
0.84
0.70
0.59
7
8
bar
3
4
5
6
9
f3 0.74 0.83 0.90 0.96 1.00 1.03 1.06
3
bar
5
f4 1.00
1.10

45
50
0.76
0.70
55
60
0.49
0.41
10
11
12
13
14
1.08 1.10 1.12 1.13 1.14
10
1.40

Example (for dew point 3C)


m3/h
C
C
bar

5000
30
40
10

=
=
=

Factor
0.94
0.84
1.08

V
f1 x f2 x f3

5000
0.94 x 0.84 x 1.08

= 5863 = DS 1200

Volume flow
Ambient temperature (f1)
Inlet temperature (f2)
Operating overpressure (f3)

Potrebbero piacerti anche