323-1059-210

Optical Metro 3500


Commissioning
Standard Release 15.0 Issue 1 June 2007

Whats inside...
Safety instructions Site commissioning

Copyright 20002007 Nortel Networks, All Rights Reserved


This document is protected by copyright laws and international treaties. All information, copyrights and any other intellectual property rights contained in this document are the property of Nortel Networks. Except as expressly authorized in writing by Nortel Networks, the holder is granted no rights to use the information contained herein and this document shall not be published, copied, produced or reproduced, modified, translated, compiled, distributed, displayed or transmitted, in whole or part, in any form or media. This information is provided as is, and Nortel Networks does not make or provide any warranty of any kind, expressed or implied, including any implied warranties of merchantability, non-infringement of third party intellectual property rights, and fitness for a particular purpose. Nortel, the Nortel logo, and the Globemark are trademarks of Nortel Networks.

Printed in Canada

iii

Contents
Safety instructions
Warnings and safety precautions 1-1 Circuit packs and small form factor pluggable (SFP) modules 1-2 Avoiding the development of static electricity 1-2 Handling, installing, or replacing circuit packs and SFP modules 1-3 Transporting circuit packs 1-3 Optical fibers 1-4 Laser radiation 1-4 Handling optical fibers 1-5 Replacing optical fibers 1-5 Radio-frequency emissions 1-5 Equipment location 1-6

0
1-1

Site commissioning
Procedures for site commissioning 2-1

2-1

List of procedures 2-1 Commissioning a new shelf processor 2-2 2-2 Commissioning a new network processor 2-5 2-3 Verifying shelf processor commissioning 2-8 2-4 Verifying network processor commissioning 2-10 2-5 Commissioning a DSM or MS DSM shelf 2-12 2-6 Decommissioning a DSM or MS DSM shelf 2-15

Terms and conditions

3-1

Commissioning

323-1059-210 Standard Rel 15.0 Iss 1 June 2007

iv Contents

Optical Metro 3500

323-1059-210 Standard Rel 15.0 Iss 1 June 2007

323-1059-

About this document


This document describes how to commission a shelf processor (SP) and network processor (NP) in preparation for network element site testing commission a DS1 Service Module (DSM) or Multiservice Distributed Service Module (MS DSM)

Supported software
This document supports the software release for Nortel Optical Metro 3500 Release 15.0.

Supported hardware
This document supports the Optical Metro 3500 shelf and Universal Optical Metro 3500 shelf.

Hardware naming conventions


The following naming conventions are used throughout this document to identify the Optical Metro 3500 hardware: The extended shelf processor (SPx) is referred to as the shelf processor. The extended network processor (NPx) is referred to as the network processor.

Audience
The following members of your company are the intended audience of this Nortel technical publication (NTP): planners provisioners network administrators transmission standards engineers

Commissioning

323-1059-210 Standard Rel 15.0 Iss 1 June 2007

vi About this document

Standards
The Telecommunications Industry Association (TIA) and the Electronics Industries Alliance (EIA) accepted RS-232 as a standard in 1997 and renumbered this standard as TIA/EIA-232. In this document, RS-232 is used to reflect current labels on the hardware and in the software for the Optical Metro 3500.

Optical Metro 3500 NTP library


EX1866p

Guides and Shelf Setup

TL1 Reference

Operations, Administration and Provisioning

Maintenance

Supporting documentation for the Optical Metro 3500 Library Change Application Procedures (CAPs) Data Communications Network Planning Guide (NTR710AM)

About the Optical Metro 3500 NTP Library (323-1059-090) Planning and Ordering Guide (NTRN10AT) Network Interworking Guide (NTCA68CA) Installation (323-1059-201) Commissioning (323-1059-210) System Testing (323-1059-222)

TL1 Reference (323-1059-190)

System Reconfiguration (323-1059-224) Security and Administration (323-1059-302) Provisioning Synchronization (323-1059-310) Protection Switching (323-1059-311) Bandwidth Management (323-1059-320) Provisioning Equipment and Facilities (323-1059-350)

Performance Monitoring (323-1059-510) Network Surveillance (323-1059-520) Alarm and Trouble Clearing (323-1059-543)

Optical Metro 3000 series DWDM Application Guide (NTRN12AA) Optical Packet Edge System Planning Guide (NTRN10YR) Optical Packet Edge System Network Applications and Management (NTRN11YR) Optical Packet Edge System User Guide (NTN465YR) Site Manager Planning and Installation Guide, Rel 9.0 (NTNM35JA)

Optical Metro 3500

323-1059-210 Standard Rel 15.0 Iss 1 June 2007

323-1059-

About this document vii

Technical support and information


For technical support and information from Nortel Networks, refer to the following table.
Technical Assistance Service For service-affecting problems: For 24-hour emergency recovery or software upgrade support, that is, for: restoration of service for equipment that has been carrying traffic and is out of service issues that prevent traffic protection switching issues that prevent completion of software upgrades For non-service-affecting problems: For 24-hour support on issues requiring immediate support or for 14-hour support (8 a.m. to 10 p.m. EST) on non-urgent issues. North America: 1-800-4NORTEL (1-800-466-7835) Note: You require an express routing code (ERC). To determine the ERC, see our corporate Web site at www.nortel.com. Click on the Express Routing Codes link. International: Varies according to country. For a list of telephone numbers, see our corporate Web site at www.nortel.com. Click on the Contact Us link. Global software upgrade support: For non-service affecting software upgrade issues North America: 1-800-4NORTEL (1-800-466-7835) International: Varies according to country. For a list of telephone numbers, see our corporate Web site at www.nortel.com. Click on the Contact Us link North America: 1-800-4NORTEL (1-800-466-7835) International: 001-919-992-8300

Commissioning

323-1059-210 Standard Rel 15.0 Iss 1 June 2007

viii About this document

Optical Metro 3500

323-1059-210 Standard Rel 15.0 Iss 1 June 2007

323-1059-

323-1059-210 1-1

Safety instructions
Warnings and safety precautions

1-

This section contains safety guidelines that must be followed for personal safety and for the correct handling and operation of equipment.

To avoid injury, follow all danger warnings provided with this product and the safety procedures established by your company. To avoid damage to equipment or service interruptions, follow all caution warnings provided with this product and the safety procedures established by your company. In this documentation, danger and caution notices are as follows. DANGER
Risk of personal injury

A danger warning with this symbol indicates a risk of personal injury. DANGER
Risk of electrical shock

A danger warning with this symbol indicates a risk of personal injury caused by an electrical hazard. CAUTION
Risk of service interruption

A caution warning with this symbol indicates a risk of service interruption or equipment damage.

Commissioning

323-1059-210 Standard Rel 15.0 Iss 1 June 2007

1-2 Safety instructions

CAUTION
Risk of circuit pack damage

A caution warning with this symbol is always used to alert the user to use antistatic protection to avoid damaging circuit packs.

Circuit packs and small form factor pluggable (SFP) modules


All circuit packs and SFP modules are subject to damage by rough handling or from electrostatic discharge. Follow the following procedures to avoid damaging the circuit packs and SFP modules. Avoiding the development of static electricity Static electricity charges build up on the body when a person walks a short distance. This static electricity is enough to damage a circuit pack or SFP module. When you work on a shelf, on cables connected to a circuit pack, on a circuit pack, or on an SFP module, always wear a skin-contact ground strap or other appropriate personal grounding device. Ground straps can be the wrist type, or the conductive shoe or heel grounder. Your company can provide antistatic protection by mounting the bays on conductive floor coverings. All circuit packs and SFP modules are shipped in antistatic containers that are marked with the following symbol.
ATTENTION OBSERVER DES PRECAUTIONS POUR LA MANIPULATION. DISPOSITIFS SENSIBLES AUX CHARGES STATIQUES ATTENTION OBSERVE PRECAUTIONS FOR HANDLING ELECTROSTATIC SENSITIVE DEVICES

Optical Metro 3500

323-1059-210 Standard Rel 15.0 Iss 1 June 2007

323-1059-

Safety instructions 1-3

Handling, installing, or replacing circuit packs and SFP modules CAUTION


Risk of service interruption

Using radio communication devices like cellular telephones can cause service interruptions. For example, a -1 W North American cellular telephone must not be used within 30 cm of a system with an open service access front cover. When handling, installing, or replacing circuit packs and SFP modules, you must observe the following precautions: To guard against electrostatic discharge (ESD), wear a wrist strap or other static grounding device before removing a circuit pack or SFP module from its package or from a shelf. Place each circuit pack and SFP module in an antistatic bag or container when it is not mounted in a shelf. Handle each circuit pack by the faceplate. Do not touch the solder side of the circuit pack, the pin connector, or the components. Do not stack circuit packs on or against each other. Inspect all circuit packs and SFP modules for damage, before installation into the shelf. Inspect all connectors to ensure pins are not damaged. Do not force circuit packs or SFP modules into their packaging material. Cover the connectors of the transmit and receive optical interface circuit packs with clean dust caps at all times.

To prevent damage to circuit packs while in storage, you must avoid the following: accumulation of dirt or dust on the pin connectors damage to the board or its components CAUTION
Risk of service interruption

Board warpage (to boards stored in areas where the humidity can exceed 95% and the temperature can exceed 70C). Transporting circuit packs When transporting circuit packs and SFP modules, place each circuit pack in its original antistatic shielding bag, padding, and box.

Commissioning

323-1059-210 Standard Rel 15.0 Iss 1 June 2007

1-4 Safety instructions

Optical fibers
Optical fibers are either single or multiple strand. The following information and precautions apply to all optical fibers. Laser radiation All Nortel optical products and associated optical test equipment use laser sources that emit light energy into fiber-optic cables. This energy is within the red (visible) and infrared (invisible) areas of the electromagnetic spectrum. Laser products are subject to federal regulations, state or provincial regulations, and local practices. Regulation 21CFR 1040 of the U.S. Bureau of Radiological Health requires manufacturers to approve each laser product as Class I, II, III, or IV depending on the characteristics of the laser radiation emitted. In terms of health and safety, Class I products present the least hazard (none at all), while class IV products present the greatest hazard. During testing and maintenance, some procedures require the handling of optical fibers and transmitters with the dust caps removed. Under these conditions, laser radiation within the limits of Class IIIb can be present. DANGER
Risk of personal injury

The radiation level produced during testing is of enough amplitude to cause injury to personnel and caution must be exercised to avoid exposure. This precaution applies to any point in the system where the laser signal can be accessed (for example, at the optical connectors on the optical interface circuit packs).

Optical Metro 3500

323-1059-210 Standard Rel 15.0 Iss 1 June 2007

323-1059-

Safety instructions 1-5

Handling optical fibers DANGER


Risk of personal injury

Avoid direct exposure to fiber-optic ends or fiber-optic connector ends where the laser signal can be accessed. Handle fiber-optic cables with caution. Position fiber-optic cables in a safe location during installation. CAUTION
Risk of equipment damage

Place all optical fiber cuttings in a appropriate container. Protect fiber-optic connectors with dust caps when they are not connected. Follow manufacturer instructions when using an optical test set. Incorrect calibration or control settings can result in hazardous levels of radiation. Replacing optical fibers When there is an accidental break in the fiber-optic cable, power off all laser sources to the cable or disconnect the remote cable end from the laser sources. The sources can be located in a central office, subscriber premises, or a remote location.

Radio-frequency emissions
The following regulatory notice applies to all Nortel SONET/SDH transmission products. This equipment has been tested and found to comply with the limits for a Class A digital device according to Part 15 of the FCC Rules. These limits are designed to provide acceptable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio-frequency energy and, if not installed and used according to the instruction manual, can cause harmful interference to radio communications. Operation of this equipment in a residential area can cause harmful interference, in which case users must correct the interference at their cost.

Commissioning

323-1059-210 Standard Rel 15.0 Iss 1 June 2007

1-6 Safety instructions

Equipment location
To prevent access by a unqualified personnel, all equipment must be placed in controlled access areas (dedicated equipment rooms, equipment closets, or the like) as described in articles 110-16, 110-17, and 110-18 of the National Electrical Code, ANSI/NFPA No. 70. If this equipment cannot be installed in a controlled area, the front cover must be locked.

Optical Metro 3500

323-1059-210 Standard Rel 15.0 Iss 1 June 2007

323-1059-

323-1059-210 2-1

Site commissioning
Procedures for site commissioning
Commissioning a new shelf processor on page 2-2 Commissioning a new network processor on page 2-5 Verifying shelf processor commissioning on page 2-8 Verifying network processor commissioning on page 2-10 Commissioning a DSM or MS DSM shelf on page 2-12 Decommissioning a DSM or MS DSM shelf on page 2-15

2-

Commissioning

323-1059-210 Standard Rel 15.0 Iss 1 June 2007

2-2 Site commissioning

Procedure 2-1 Commissioning a new shelf processor


The process of commissioning a shelf processor prepares a network element for site testing. Commissioning includes the following tasks: changing the password for a default user ID adding user accounts to the network element setting the centralized security administration (CSA) attributes for the network element setting the time of day synchronization status as active and setting the offset threshold value selecting the network processor timing source for time of day synchronization changing the network element date and time changing the network element time zone changing the network element name Requirements To perform this procedure you must directly connect your PC to the shelf processor at the network element site, for each network element in the system commission the shelf processor before you commission the NPx CAUTION
Risk of loss of functionality

Ensure that every network element and network processor has a unique system identifier (SID). If you are changing the name of a network element or NPx, ensure that the new SID is unique.
Step 1 2 3 Action If the shelf power is off, put the power switch on the face of power cards A and B to on. Connect the PC to the RS232 connector on the shelf processor. Refer to Installation, 323-1059-201 for RS-232 DCE DB25 cable pinout and assembly. Launch the Site Manager application and log in to the network element. For instructions, see 323-1059-302, Procedures for logging in to a network element on page 2-1.
continued

Optical Metro 3500

323-1059-210 Standard Rel 15.0 Iss 1 June 2007

323-1059-

Site commissioning 2-3 Procedure 2-1 (continued) Commissioning a new shelf processor Step 4 5 6 7 8 9 10 Action Change the password of the default User ID. See 323-1059-302, Procedures for user account management and administration on page 3-1. Record the new default User ID passwords in the commissioning data table; see Network element commissioning data on page 2-4. Repeat step 4 and step 5 to change the password for each default User ID. Add a user account to the network element. See 323-1059-302, Procedures for user account management and administration on page 3-1. Record the new User ID and password in the commissioning data table. See Network element commissioning data on page 2-4. Repeat step 7 and step 8 for every new User ID. Set the CSA attributes for the network element. Specify the authentication mode, the alternate authentication mode, the primary and secondary security gateways, and the shared secret. See 323-1059-302, Procedures for user account management and administration on page 3-1. If time of day synchronization will be implemented on this network element, go to step 12. Otherwise, go to step 15. Set the time of day synchronization status to On and set the Offset Threshold value. See 323-1059-302, Editing time of day synchronization parameters on the network processor or network element on page 8-2. Set the time of day timing servers for the shelf processor. See 323-1059-302, Setting time of day servers on the network processors or network element on page 8-4. Set the time of day timing offset and daylight savings time parameters. See 323-1059-302, Setting time offset and daylight savings offset on page 8-8. You have set up time of day synchronization on this shelf processor. 15 Set the network element date and time, time zone, and name. See 323-1059-302, Procedures for user account management and administration on page 3-1. Note: After you change the name of the network element, and click OK, the network element will restart. 16 17 Record the new network element name in the commissioning data table. See Network element commissioning data on page 2-4. Log in to the network element. See 323-1059-302, Logging in to a network element automatically on page 2-42.
end

11 12

13

14

Commissioning

323-1059-210 Standard Rel 15.0 Iss 1 June 2007

2-4 Site commissioning

Network element commissioning data


Network element number and location TID User ID Admin Surveil New password

Optical Metro 3500

323-1059-210 Standard Rel 15.0 Iss 1 June 2007

323-1059-

Site commissioning 2-5

Procedure 2-2 Commissioning a new network processor


The process of commissioning a network processor includes the following tasks: changing the password for a default User ID adding user accounts to the NPx setting the centralized security administration (CSA) attributes for the network processor setting the time of day parameters on the NPx setting the timing sources for time of day synchronization on the NPx setting the NPx time zone changing the name of the NPx Note 1: The NPx continuously retrieves the date and time from the shelf processor and updates the date and time if the difference is more than 2 minutes. Note 2: The NPx COLAN port is 10BaseT and only supports half duplex connections. Connected equipment with different settings might result in connectivity problems with the NPx. Requirements To perform this procedure you must directly connect your PC to the shelf processor at the NPx site. Refer to Installation, 323-1059-201 for RS-232 DCE DB25 cable pinout and assembly commission the shelf processor before commissioning the NPx CAUTION
Risk of loss of functionality

Ensure that every network element and network processor has a unique system identifier (SID). If you are changing the name of a network element or network processor, ensure that the SID name is unique.
continued

Commissioning

323-1059-210 Standard Rel 15.0 Iss 1 June 2007

2-6 Site commissioning Procedure 2-2 (continued) Commissioning a new network processor

Step 1 2

Action Ensure the NPx is installed in the shelf. Launch the Site Manager application and log in to the network processor. For instructions, see 323-1059-302, Procedures for logging in to a network element on page 2-1. Change the password of a default user ID. See 323-1059-302, Procedures for user account management and administration on page 3-1. Record the new user ID passwords in the commissioning data table. See Network processor commissioning data on page 2-7. Repeat step 3 and step 4 to change the password for each default User ID. Add a user account to the network processor. See 323-1059-302, Procedures for user account management and administration on page 3-1. Record the new user ID and password in the commissioning data table. See Network processor commissioning data on page 2-7. Repeat step 6 and step 7 for each new user ID to be added. Click OK to close the dialog box. Set the CSA attributes for the network processor. Specify the authentication mode, the alternate authentication mode, the primary and secondary RADIUS servers, and the shared secrets. See 323-1059-302, Procedures for user account management and administration on page 3-1. If time of day synchronization will be implemented on this network element, go to step 12. Otherwise, go to step 15. Set the time of day synchronization parameters including the status, minimum polling interval, maximum polling interval, and offset interval. See 323-1059-302, Editing time of day synchronization parameters on the network processor or network element on page 8-2. Set the time of day timing servers for the network processor. See 323-1059-302, Setting time of day servers on the network processors or network element on page 8-4. Set the time of day timing offset and daylight savings time parameters. See 323-1059-302, Setting time offset and daylight savings offset on page 8-8. Set the network processor time zone and name. See 323-1059-302, Procedures for user account management and administration on page 3-1. Record the new name of the NPx in the commissioning data table. See Network element commissioning data on page 2-4. Log in to the NPx using the new name. To provision the NPx, refer to the Site Manager network software upgrade CAP.
end

3 4 5 6 7 8 9 10

11 12

13

14 15 16 17 18

Optical Metro 3500

323-1059-210 Standard Rel 15.0 Iss 1 June 2007

323-1059-

Site commissioning 2-7

Network processor commissioning data


Network processor number and location TID User ID Admin Surveil New password

Commissioning

323-1059-210 Standard Rel 15.0 Iss 1 June 2007

2-8 Site commissioning

Procedure 2-3 Verifying shelf processor commissioning


Use this procedure to verify and validate that the shelf processor has been properly commissioned. The commisioning information should be compared to site documents to ensure accuracy. Requirements To perform this procedure you must directly connect your PC to the shelf processor at the network element site, for each network element in the system commission the shelf processor before you commission the NPx CAUTION
Risk of loss of functionality

Ensure that every network element and network processor has a unique system identifier (SID). If you are changing the name of a network element or network processor, ensure that the new SID is unique.
Step 1 2 3 Action If the shelf power is off, set the power switch on the face of power cards A and B to on. Connect the PC to the RS-232 connector on the shelf processor. Refer to Installation, 323-1059-201 for RS-232 DCE DB25 cable pinout and assembly. Launch the Site Manager application and log in to the network element. For instructions, see 323-1059-302, Procedures for logging in to a network element on page 2-1. Ensure the customer or designated representative has the applicable user ID and password settings. Display and verify the user account details for a network processor or network element. For instructions, see 323-1059-302, Procedures for user account management and administration on page 3-1. Display and verify the centralized security administration (CSA) attributes for the shelf processor. See 323-1059-302, Procedures for user account management and administration on page 3-1.
continued

4 5

Optical Metro 3500

323-1059-210 Standard Rel 15.0 Iss 1 June 2007

323-1059-

Site commissioning 2-9 Procedure 2-3 (continued) Verifying shelf processor commissioning Step 7 Action Display and verify the time of day details for a shelf processor or network element. For instructions, see 323-1059-302, Displaying time of day server details and parameters on page 8-7. Display and verify the network element date and time, time zone, name, node type, node function, software release, default AINS value, and SDTH value. For instructions, see 323-1059-302, Procedures for user account management and administration on page 3-1. Set the network element date and time as required. For instructions, see 323-1059-302, Procedures for user account management and administration on page 3-1.
end

Commissioning

323-1059-210 Standard Rel 15.0 Iss 1 June 2007

2-10 Site commissioning

Procedure 2-4 Verifying network processor commissioning


Use this procedure to verify and validate that the network processor has been properly commissioned. The commissioning information should be compared to site documents to ensure accuracy. Note: The NPx COLAN port is 10BaseT and only supports half duplex connections. Connected equipment with different settings might result in connectivity problems with the NPx. Requirements To perform this procedure you must directly connect your PC to the shelf processor at the NPx site. Refer to Installation, 323-1059-201 for RS-232 DCE DB25 cable pinout and assembly commission the shelf processor before commissioning the NPx CAUTION
Risk of loss of functionality

Ensure that every network element and NPx has a unique system identifier (SID). If you are changing the name of a network element or NPx, ensure that the SID name is unique.
Step 1 2 Action Ensure the NPx is installed in the shelf. Launch the Site Manager application and log in to the network processor. For instructions, see 323-1059-302, Procedures for logging in to a network element on page 2-1. Ensure the customer or designated representative has the applicable user ID and password settings. Display and verify the user account details for a network processor or network element. For instructions, see 323-1059-302, Procedures for user account management and administration on page 3-1. Display and verify the centralized security administration (CSA) attributes for the network processor. See 323-1059-302, Procedures for user account management and administration on page 3-1 Display and verify the time of day details for a network processor or network element. For instructions, see 323-1059-302, Displaying time of day server details and parameters on page 8-7.
continued

3 4

Optical Metro 3500

323-1059-210 Standard Rel 15.0 Iss 1 June 2007

323-1059-

Site commissioning 2-11 Procedure 2-4 (continued) Verifying network processor commissioning Step 7 Action Display and verify the network element time zone and name. For instructions, see 323-1059-302, Procedures for user account management and administration on page 3-1. Set the network element date and time as required. For instructions, see 323-1059-302, Procedures for user account management and administration on page 3-1.
end

Commissioning

323-1059-210 Standard Rel 15.0 Iss 1 June 2007

2-12 Site commissioning

Procedure 2-5 Commissioning a DSM or MS DSM shelf


Use this procedure to commission a DS1 Service Module (DSM) or Multiservice Distributed Service Module (MS DSM). The DSM connects to the host Optical Metro 3500 through OC-3x4/STM-1x4 or OC-3/STM-1 circuit packs. The MS DSM connects to the host Optical Metro 3500 through OC-3x4/STM-1x4, OC-12/STM-4, or OC-12x4/STM-4x4 circuit packs. Requirements To perform this procedure, ensure that the DSM or MS DSM shelf is installed. Refer to Installation, 323-1059-201. if the DSM or MS DSM power is off, the power switch on power cards A and B is on the MS DSM shelf is equipped with the required I/O modules. The MS DSM can be equipped with up to three DS1 I/O modules, each supporting 28 DS1 facilities, and two types of DS3 I/O modules (supporting six DS3 or three DS3 facilities). the MS DSM shelf is equipped with the required expansion modules (DS3 or 8x10/100BT). These modules are supported in expansion slots 3 to 6. DS3 pluggable modules support equipment protection, with slots 3 and 5 used for the working module and slots 4 and 6 used for the protected module. The 8x10/100BT pluggable module does not support equipment protection. 8x10/100BT pluggables can be independently provisioned in the expansion slots. the host OC-n facility is provisioned section data communications channel (SDCC) is provisioned for the host OC-n facility the host OC-n facility is not already provisioned as a DSM or MS DSM link there are no cross-connects on the host OC-n facility the host OC-n facility is not provisioned as a shelf timing reference the host OC-n facility is not a member of a facility fault protection (FFP) group
continued

Optical Metro 3500

323-1059-210 Standard Rel 15.0 Iss 1 June 2007

323-1059-

Site commissioning 2-13 Procedure 2-5 (continued) Commissioning a DSM or MS DSM shelf

Step 1

Action Insert the aggregate circuit pack in slot 1 of the DSM or MS DSM shelf and connect the circuit pack to the host OC-n port. The host OC-n circuit pack must be in an odd slot. Refer to Installation, 323-1059-201, for information about inserting aggregate circuit packs and connecting to the host Optical Metro 3500. Wait for the aggregate circuit pack to auto-provision. The aggregate circuit pack appears in the DSM tab of Site Manager once the auto-provision completes. To open the DSM tab, select Shelf Level View from the Configuration drop-down menu, then select the DSM tab. Note: If necessary, you can manually provision the aggregate circuit pack, then connect aggregate circuit pack to the host OC-n port.

3 4 Defining DS1 services 5 6

Repeat step 1 and step 2 for the even slot aggregate circuit pack. Define a site address for the DSM or MS DSM. See 323-1059-350, Procedures for equipment provisioning on page 2-1.

Edit DS1 facility signal attributes on the DSM or MS DSM. See 323-1059-350, Procedures for facility provisioning on page 2-1. Add the appropriate cross-connects between DS1 ports and other endpoints. See 323-1059-320, Procedures for end-to-end connection management on page 1-1.

Defining DS3 services on the MS DSM 7 8 Insert the DS3 pluggable module in expansion slot 3 or 5. Wait for the pluggable module to auto-provision. The pluggable module appears in the DSM tab of Site Manager once the auto-provision completes. To open the DSM tab, select Shelf Level View from the Configuration drop-down menu, then select the DSM tab. Note: If necessary, you can manually provision the expansion slot, then insert the pluggable module into the slot. 9 10 11 Repeat step 7 and step 8 for the even slot pluggable module. Edit DS3 facility signal attributes on the MS DSM. See 323-1059-350, Procedures for facility provisioning on page 2-1. Add the appropriate cross-connects between DS3 ports and other endpoints. See 323-1059-320, Procedures for end-to-end connection management on page 1-1.

Defining Ethernet services on the MS DSM 12 Insert the pluggable 8x10/100BT module in expansion slot 3, 4, 5, or 6.
continued

Commissioning

323-1059-210 Standard Rel 15.0 Iss 1 June 2007

2-14 Site commissioning Procedure 2-5 (continued) Commissioning a DSM or MS DSM shelf Step 13 Action Wait for the pluggable module to auto-provision. The pluggable module appears in the DSM tab of Site Manager once the auto-provision completes. To open the DSM tab, select Shelf Level View from the Configuration drop-down menu, then select the DSM tab. Note: If necessary, you can manually provision the expansion slot, then insert the pluggable module into the slot. 14 15 Edit Ethernet facility signal attributes on the MS DSM. See 323-1059-350, Procedures for facility provisioning on page 2-1. Add the appropriate cross-connects between Ethernet ports and other endpoints. See 323-1059-320, Procedures for end-to-end connection management on page 1-1.
end

Optical Metro 3500

323-1059-210 Standard Rel 15.0 Iss 1 June 2007

323-1059-

Site commissioning 2-15

Procedure 2-6 Decommissioning a DSM or MS DSM shelf


Use this procedure to decommission a DS1 Service Module (DSM) or Multiservice Distributed Service Module (MS DSM).
Step 1 2 3 Action Disconnect all fibers from the DSM or MS DSM. Delete all cross-connects on the DSM or MS DSM. See 323-1059-320, Procedures for end-to-end connection management on page 1-1. Place out-of-service (OOS) all DS1, DS3, and Ethernet facilities on the DSM or MS DSM. See 323-1059-350, Procedures for facility provisioning on page 2-1. Delete all DS1, DS3, and Ethernet facilities on the DSM or MS DSM. See 323-1059-350, Procedures for facility provisioning on page 2-1. Place out-of-service (OOS) all equipment in the MS DSM expansion slots. See 323-1059-350, Procedures for equipment provisioning on page 2-1. For DS3 pluggable modules, first place the even slot out-of-service. Delete all equipment in the MS DSM expansion slots. See 323-1059-350, Procedures for equipment provisioning on page 2-1. For DS3 pluggable modules, first delete the even slot. Place out-of-service (OOS) the OC-n facility of the aggregate circuit pack in the even slot. See 323-1059-350, Procedures for facility provisioning on page 2-1. Place out-of-service (OOS) the SFP of the aggregate circuit pack in the even slot. See 323-1059-350, Procedures for facility provisioning on page 2-1. Delete the SFP in the even slot of the MS DSM. See 323-1059-350, Procedures for equipment provisioning on page 2-1. Place out-of-service (OOS) the aggregate circuit pack in the even slot of the DSM or MS DSM. See 323-1059-350, Procedures for equipment provisioning on page 2-1. Delete the aggregate circuit pack in the even slot of the DSM or MS DSM. See 323-1059-350, Procedures for equipment provisioning on page 2-1. Repeat step 7 to step 11 for the aggregate circuit pack in the odd slot.
end

4 5

8 9 10

11 12

Commissioning

323-1059-210 Standard Rel 15.0 Iss 1 June 2007

2-16 Site commissioning

Optical Metro 3500

323-1059-210 Standard Rel 15.0 Iss 1 June 2007

323-1059-

3-1

Terms and conditions

3-

Completion of a purchase agreement is required prior to purchasing Optical Metro 3500 products and/or services. Contact one of the following: your Nortel Networks sales person email CONTMGNT@nortel.com

Statement of Conditions
Portions of the code in this software may be Copyright 1979, 1980, 1983, 1986, 1988, 1989, 1991, 1992, 1993, 1994 The Regents of the University of California. All rights reserved. Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met: 1 Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer. 2 Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution. 3 All advertising materials mentioning features or use of this software must display the following acknowledgement: This product includes software developed by the University of California, Berkeley and its contributors. 4 Neither the name of the University nor the names of its contributors may be used to endorse or promote products derived from this software without specific prior written permission. THIS SOFTWARE IS PROVIDED BY THE REGENTS AND CONTRIBUTORS AS IS AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE REGENTS OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER
Commissioning 323-1059-210 Standard Rel 15.0 Iss 1 June 2007

3-2 Terms and conditions

CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Portions of the code in this software may be Copyright 1988 Juniper Networks, Inc. All rights reserved. Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met: 1 Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer. 2 Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution. THIS SOFTWARE IS PROVIDED BY THE AUTHOR AND CONTRIBUTORS ``AS IS'' AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE AUTHOR OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Portions of the code in this software may be Copyright 1991-2, RSA Data Security, Inc. Created 1991. All rights reserved. License to copy and use this software is granted provided that it is identified as the RSA Data Security, Inc. MD5 Message-Digest Algorithm in all material mentioning or referencing this software or this function. License is also granted to make and use derivative works provided that such works are identified as derived from the RSA Data Security, Inc. MD5 Message-Digest Algorithm in all material mentioning or referencing the derived work.

Optical Metro 3500

323-1059-210 Standard Rel 15.0 Iss 1 June 2007

323-1059-

Terms and conditions 3-3

RSA Data Security, Inc. makes no representations concerning either the merchantability of this software or the suitability of this software for any particular purpose. It is provided as is without express or implied warranty of any kind. These notices must be retained in any copies of any part of this documentation and/or software. $FreeBSD: src/lib/libmd/md5c.c,v 1.11 1999/12/29 05:04:20 peter Exp $This code is the same as the code published by RSA Inc. It has been edited for clarity and style only.

Commissioning

323-1059-210 Standard Rel 15.0 Iss 1 June 2007

3-4 Terms and conditions

Optical Metro 3500

323-1059-210 Standard Rel 15.0 Iss 1 June 2007

323-1059-

Nortel

Optical Metro 3500


Commissioning

This document is protected by copyright laws and international treaties. All information, copyrights and any other intellectual property rights contained in this document are the property of Nortel Networks. Except as expressly authorized in writing by Nortel Networks, the holder is granted no rights to use the information contained herein and this document shall not be published, copied, produced or reproduced, modified, translated, compiled, distributed, displayed or transmitted, in whole or part, in any form or media. This information is provided as is, and Nortel Networks does not make or provide any warranty of any kind, expressed or implied, including any implied warranties of merchantability, non-infringement of third party intellectual property rights, and fitness for a particular purpose. Nortel, the Nortel logo, and the Globemark are trademarks of Nortel Networks. 323-1059-210 Standard Release 15.0 Issue 1 June 2007 Printed in Canada

Copyright