UNIVERSITI TEKNOLOGI MARA FINAL EXAMINATION

COURSE COURSE CODE EXAMINATION TIME

MEASUREMENT AND ESTIMATING II QSV253 APRIL 2011 3 HOURS

INSTRUCTIONS TO CANDIDATES This question paper consists of two (2) parts : PART A (1 Question) PART B (3 Questions)

2.

Answer three (3) questions only: i) ii) Answer the question from PART A in Traditional Taking Off Paper, Answer two (2) questions from PART B in the Answer Booklet. Start each answer on a new page.

3.

Do not bring any material into the examination room unless permission is given by the invigilator. Please check to make sure that this examination pack consists of: i) ) ) iv) v) vi) the Question Paper a two-page Appendix 1(1 )(2) (Drawing JBN/APR 2011/QSV253/1-2) an Answer Booklet - provided by the Faculty an Answer Booklet Cover - provided by the Faculty Traditional Taking Off Papers - provided by the Faculty a Malaysian Standard Method of Measurement Building Works (SMM2) - provided by the Faculty

4.

DO NOT TURN THIS PAGE UNTIL YOU ARE TOLD TO DO SO


This examination paper consists of 5 printed pages
Hak Cipta Universiti Teknologi MARA CONFIDENTIAL

CONFIDENTIAL

AP/APR2011/QSV253

PART A

QUESTION 1 Vista Impian Resources have been awarded a contract to construct one (1) mock up unit of single storey semi-detached house on Lot 25, Taman Iskandar Perdana, Seri Iskandar. As a quantity surveyor, you are required to prepare a bill of quantity for plywood flush door. With reference to the following drawings: JBN/APR2011/QSV253/1 JBN/APR 2011/QSV253/2 Measure the quantities for all related works to the plywood flush door (D2) for the proposed project. You may make all necessary and reasonable assumptions where applicable. (50 marks)

Hak Cipta Universiti Teknologi MARA

CONFIDENTIAL

CONFIDENTIAL

AP/APR2011/QSV253

PARTB

QUESTION 1 En. Hamdan wants to replace his current car porch roof tile with "Monier" concrete roof tile. The area of his car porch is 12 m2. He has hired your company for the job. You are required to: a) Calculate the price to install 1 m2 "Monier" concrete roof tile nailed on 50 mm x 25 mm Grade B timber battens (including timber battens). (15 marks) b) Calculate the quantities needed for "Monier" concrete roof tile (5 marks) c) Calculate the total cost of installing "Monier" concrete roof tile (5 marks) MATERIAL "Monier" concrete roof tile Galvanised nails Treated Grade B timber PRICE @ RM 2.00 per piece @RM 15.00 per kg @ 1,500.00 per tonne

TYPE OF TILE

DIMENSION

NO. OF TILE PER 10 m2 161

NAILS

TIMBER BATTENS

"Monier" concrete roof tile

375 mm x 225 mm

1kg

35 m long (0.044 m3)

SKILLED AND UNSKILLED LABOUR 1 V* hours

LABOUR WAGES 1 x Roofer 1 x Labourer Wastage for "Monier" concrete roof tile Wastage for Grade B timber Profit and Overhead 1 tonne
Hak Cipta Universiti Teknologi MARA

8 HOURS PER DAY @ RM 80.00 per day @ RM 60.00 per day @ 8 pieces @ 10% @15% @1.4m 3 CONFIDENTIAL

CONFIDENTIAL

AP/APR2011/QSV253

QUESTION 2 A chalet project in Cherating, Terengganu uses bakau pile as the deep foundation. The average driven for each point is 5.00 m long. a) Build up the unit rate to supply, handle, transport, pitch and drive bakau piles. (12 marks) b) If one (1) pile cap needs about nine (9) numbers of bakau pile, calculate the time needed to drive twelve (12) numbers of pile caps. (7 marks) c) Calculate the total cost of driving bakau pile works. (6 marks)

MATERIAL Bakau Pile LABOUR CONSTANT Handle and Pitch Bakau Pile Drive Bakau Pile LABOUR WAGES 1 x Skilled Workers 1 x Labourer DRIVING COST Rental of Pile Driver Diesel Lubricant Transportation Cost Wastage For Pile Profits and Overheads

PRICE @ RM 20.00 per pile MANHOURS @ 0.10 hour per pile @ 80 pile per day 8 HOURS PER DAY @ RM 90.00 per day @ RM 70.00 per day

@ RM 300.00 per day @ RM 30.00 per day @RM 20.00 per day @ RM 5.00 per pile @5% @15%

Hak Cipta Universiti Teknologi MARA

CONFIDENTIAL

CONFIDENTIAL

AP/APR2011/QSV253

QUESTION 3 Explain with example the following terms:a) Preliminaries (10 marks) b) Provisional sum (10 marks) c) Pro rata rate (5 marks)

END OF QUESTION PAPER

Hak Cipta Universiti Teknologi MARA

CONFIDENTIAL

iviiNaaidNOO
US9Z/KSX)M0Z ydv/Nar
ON DNIAAVaa UOZUHdV STN "1VZIH aiva 31V0S xa NMVUQ

V y v W |Bo|ou)|ai njSJSAjun Bjdjo yen @

(s - i -N)

(S - - N)

NVld dOO^

NVld y O O l d
D
& > <

niAivy Nia WDIVH QHOIAI Hoyod W D :A3 03X03H0

o o o

D
fSM) : 1N3IAI313

NVld dOOH

Nvnd uooid
: 31111 9NIMVUQ

-*>

(IM)

(M)

(xas)

rn

h=rf 1 J fe

D
TIVH

DNiAn

wooyaaa ygisvw

xvasd 'uvaNVXSi IU3S 'VNvaaad HVONVMSI NVWVI 'SZ ion NO asnoH asHOVisa was A3H01S 3H0NIS QBSOdOUd

(a^

' 31111 l o s r o a d siavonddv 3M3HM SNOIldlMMSSV 31SVN0SV3M QNV AaVSS303N TIV 3WIN A V flOA VM saaiSHioa NO aaisind 1N3W30 >IH1 UIUU6I. H1IM XH1 ulUiOSl T1VHS TIVM JO SS3N>I0IH1 '9 aawiad wniNiwmv OOOM
aaiNivd aasva Nisay OAXIV SIVOO 3ayHi H I I M aaiNivd aa TIVHS

?
wooaagg

T 131101

5>)
V 3 W AllWVd W O O O

Z 131101/

i:

*-(P)

aaawiidosaovjynsaasodxanv > Tina 1VO0 3N0 HUM aaiNlVd 38 TIVHS aiaaoNOO ao xaoMoiya H I I M IOVINOO NI S30Vddns yaawu T I V e aaivis asiMyaHio ssaiNn a aavao
a a i v a a i s a n s s a a d NMVS

T1VH DNINIQ

wooyagg

3yois
->'-

3a TIVHS aaawu aasodxaNn T I V z


CH1V1S

"(?
M O O

asiMaaHio ssaiNn v aavao aaivaai aanssaad lHonoaM aa TIVHS aaawu aasodxa TIV ' t :S310N

vavw IQOION31 uisaaAiNn

e93ASD/H-02 HdV/dV

U H XIQNSddV

nVHN3QldN0D

CONFIDENTIAL

APPENDIX 1(2)
_19mm THK. CEMENT PLASTER ON BOTHSIDES -25mm X 3mm THK X 150mm GIRTH GALVANISED STEEL HOLD FAST. -75 X 19mm H.W PACKING PIECE P.C LINTEL TO ENGR'S DETAIL -35 X 13 H.W ARCHITRAVE 75 X 19mm H.W PACKING PIECE 35 X 13 H.W ARCHITRAVE -102 X 25mm H.W DOOR STILE -150 X 51mm H.W DOOR FRAME 38 X 19mm H.W EDGING PIECE 102 X 25mm H.W TOP RAIL -6.5mm THK. PLYWOOD BOTHSIDES. -150 X 51mm H.W DOOR FRAME -38 X 19mm H.W EDGING PIECE NOTES:

AP/APR2011/QSV253

UNIVERSITI TEKNOLOGI MARA

6.5mm THK. PLYWOOD BOTHSIDES.

o o

-35 X 13mm H.W ARCHITRAVE


1,

YOU MAY MAKE ALL NECESSARY AND REASONABLE ASSUMPTIONS WHERE APPLICABLE 840
e

SECTION B-B
(SCALE 1:5)

PROJECT TITLE : PROPOSED SINGLE STOREY SEMI DETACHED HOUSE ON LOT 25, TAMAN ISKANDAR PERDANA, SERI ISKANDAR, PERAK

-152 X 25mm H.W MIDDLE RAIL

A
1

-><-

L_

DRAWING TITLE:

DOOR DETAILS
6.5mm THK. PLYWOOD BOTHSIDES. ELEMENT:

B
-152 X 25mm H.W BOTTOM RAIL

L_B

CHECKED BY: 38 X 19mm H.W EDGING PIECE MOHD HAIQAL BIN RAMLI

DRAWN BY SCALE

RIZAL AS SHOWN APRIL 2011

SECTION A-A
(SCALE 1:5) (SCALE 1:25) Hak Cipta Universiti Teknologi MARA

DATE DRAWING NO.

PLYWOOD FLUSH POOR (D2)

JBN/APR 2011/QSV253/2

CONFIDENTIAL

Potrebbero piacerti anche