Sei sulla pagina 1di 7

TECHNICAL DATA SHEET

Designation: HEAVY DUTY ANCHOR

Reference Date Revision Page Codes

FT SLV ingles 04.02.09 6 1 de 7 SLVT, SLVI, SLVE

SLVT

SLVE

1.-CHARACTERISTICS Metallic anchor, with functioning principle by expansion and installation by controlled torque. Male thread Use in non-craked concrete Easy assembly Use for heavy duty loads (static or quasy-static) Versions: zinc yellow pasitavated bolt and stud. Through fastening installation. Zinc yellow passivated bolt version apporved by the Instituto Eduardo Torroja de Ciencias de la Construccin (EOTA member) with European Technical Approval ETA 04/0100 option 8, from European Organization of Technical Approvals guide ETAG-001

TECHNICAL DATA SHEET


Designation: HEAVY DUTY ANCHOR

Reference Date Revision Page Codes

FT SLV ingles 04.02.09 6 2 de 7 SLVT, SLVI, SLVE

2.- MATERIALS
ZINC YELLOW PASSIVATED BOLT ITEM COMPONENT Class 8.8 UNE EN ISO 898-1, zinc yellow pasivated 5m ISO 4042 A2L Zinc yellow pasivated 5m ISO 4042 A2L Tube EN 10305-2 -E235+C (1.0308) zinc yellow pasivated 5m ISO 4042 A2L ZINC YELLOW PASSIVATED STUD

1 2 3 4 5 6 7

BOLT DIN 931 WASHER DIN 9021 SLEEVE ANTIGIRUS EXPANSION SLEEVE CONE STUD

----Zinc yellow pasivated 5m ISO 4042 A2L Tube EN 10305-2 - E235+C (1.0308) zinc yellow pasivated 5m ISO 4042 A2L

Poliamide 6.6 Tube EN 10305-2 -E235+C (1.0308) zinc yellow pasivated 5m ISO 4042 A2L EN 10277-3 - 1.0718 zinc yellow pasivated 5m ISO 4042 A2L -----Tube EN 10305-2 - E235+C (1.0308) zinc yellow pasivated 5m ISO 4042 A2L EN10277-3 - 1.0718 zinc yellow pasivated 5m ISO 4042 A2L EN 10277-5 - 1.1191+C zinc yellow pasivated 5m ISO 4042 A2L

TECHNICAL DATA SHEET


Designation: HEAVY DUTY ANCHOR

Reference Date Revision Page Codes

FT SLV ingles 04.02.09 6 3 de 7 SLVT, SLVI, SLVE

3.- DIMENSIONS
M20 x190 M10x110 M10x130 M12x130 M12x160 M16x150 M16x180 M20x160 M20x220 M24x210 210 111 24 70 26 72 32 5 36 SLVT20220 SLVT24210 SLVE24210 SLVT24240 SLVE24240 M24x240 240 141 M8x100 M8 100 58.5 8 30.5 11 24 120 78.5 M8x120

SIZE
dp: bolt diameter l: bolt length l3: sleeve length l4: antivirus length
[mm] [mm] [mm] [mm]

M10 110 60 10 34.5 13 30 130 80

M12 130 73 11 40 15 37 160 103

M16 150 78 16 50 19 50 180 108

M20 160 190 76 106 20 60 22 60 220 136

M24

l5: expans. sleeve length [mm] l6: cone length d2: washer diameter d3: sleeve diameter d4: antivirus diameter
[mm] [mm] [mm] [mm]

d5: expans. sleeve diam. [mm] d6: cone diameter s2: washer thickness sw : nut key Zinc yellow passivated bolt codes
[mm] mm] [mm]

12

15

18

24

28

2 13 SLVT08100 SLVT08120 SLVT10110

2.5 17 SLVT10130 SLVT12130

3 19 SLVT12160 SLVT16150

3 24 SLVT16180 SLVT20160 SLVE20160

4 30 SLVT20190 SLVE20190

SLVE08100

SLVE08120

SLVE10110

SLVE10130

SLVE12130

SLVE12160

SLVE16150

SLVE16180

4.- INSTALLATION DATA

SLVE20220

Zinc yellow passivated stud codes

TECHNICAL DATA SHEET


Designation: HEAVY DUTY ANCHOR M10x110 M10x130 M12x130 M12x160 M16x150

Reference Date Revision Page Codes M16x180 M20x160 M20x190

FT SLV ingles 04.02.09 6 4 de 7 SLVT, SLVI, SLVE M20x220 M24x210 32 195 175 155 310 60 30 35 250 465 233 SLVT20220 SLVT24210 SLVE24210 SLVT24240 SLVE24240 60 M24x240

M8x100 [mm] [mm] [mm] [mm] [mm] [mm] [mm] [Nm] [mm] [mm] 12 90 78 70

SIZE
d0: drill diameter h1: drill depth hnom: embedment depth hef: effective depth hc: base material thick. tfix: fixture thickness dw: fixture diameter Tins: installation torque scr,N: critical spacing dist. ccr,N: critical edge distance

M8x120

15 100 87.5 76.5 153 20 17 50 230 115 SLVT10110 SLVT10130 40

18 115 102 89 178 25 20 80 267 134 SLVT12130 SLVT12160 55

24 140 122 106 212 25 26 120 318 159 SLVT16150 SLVT16180 SLVT20160 SLVE20160 55 2

28 175 156 140.5 281 30 31 200 422 211 SLVT20190 SLVE20190

140 20 14 25 211 105 SLVT08100 SLVE08100 SLVT08120 SLVE08120 40

Zinc yellow passivated bolt codes

SLVE10110

SLVE10130

SLVE12130

SLVE12160

SLVE16150

SLVE16180

Zinc yellow passivated stud codes

5.- INSTALLATION PROCEDURE

Before placing the anchor, checks to be made to ensure the strength class of the concrete is not lower than that to which the characteristic loads apply The concrete to be well compacted, e.g. without significant voids Base material temperatures during installation: -5 / + 40 C (80 C in a short period of time) Anchors to be installed ensuring not less than the specified embedment depth, The edge distance and spacing to be kept to the specified values, no minus tolerances to be allowed

SLVE20220

TECHNICAL DATA SHEET


Designation: HEAVY DUTY ANCHOR

Reference Date Revision Page Codes

FT SLV ingles 04.02.09 6 5 de 7 SLVT, SLVI, SLVE

Drill to the minimum depth and diameter specified, maintaining perpendicular to the surface of the base material. Fixture holes themselves can be used as template. When drilling holes, care to be taken not to damage reinforcement in close proximity to the hole position. Action to be taken in the event that drilling is aborted, e.g. due to encountering reinforcement. It is recommended to install the anchors immediately beside the aborted drill hole, provide that anchoring depth is increased by the depth of the aborted drill hole, or make a new drilling at a minimum distance away of two times the depth of the aborted hole. Alternatively, a smaller distance may be chosen, provided the aborted drill hole is filled with high strength mortar. However, unless the aborted drill hole is filled with mortar, it is not permissible under a shear or oblique tension load for it to be closer than installation depth hnom in the direction of load application. Thoroughly clean hole from dust and drilling fragments. For holes to be subjected to temperatures below 0 C, measures to be taken to avoid the ingress of water into the hole and subsequent risk of local cracking of the concrete due to ice expansion. To introduce the anchor into the hole up to the embedment depth through the fixture. The installation minimum depth must be such that the sleeve notch is not visible out of the base material once installed. A hammer can be use to assure this depth. Do not apply any intermediate lay between the fixture and the washer (sealant, etc.). Apply the specified torque with a torque wrench. In case of holes with diameters higher than specified use washers of bigger diameter and thickness, but in this case it is not assured a correct distribution of shear loads amongst all the anchors of a same group. The shear load will be applied on those anchors with the correct fixture diameter. Due to the heavy loads transmitted by this anchor, when design of the structure it may be considered all the applied loads, including those transmitted by the anchor itself.

6.- CHARACTERISTIC RESISTANCES 6.1.- Characteristic resistances* in non-cracked C20/25** for an isolated anchor (without spacing and edge distance effects) are as per this table: METRIC
Zinc yellow passivated bolt

M8
SLVT08100 SLVT08120

M10
SLVT10110 SLVT10130

M12
SLVT12130 SLVT12160

M16
SLVT16150 SLVT16180

M20
SLVT20160 SLVT20190 SLVT20220

M24
SLVT24210 SLVT24240

NR,k tension VR,K: shear

[KN] [KN]

29.3 21.9
SLVE08100 SLVE08120

33.7 48.7
SLVE08100 SLVE08120

42.3 84.6
SLVE10110 SLVE10130

55.0 93.6
SLVE12130 SLVE12160

83.9 112.1
SLVE16150 SLVE16180

97.3 129.3
SLVE20160 SLVE20190 SLVE20220

Zinc yellow passivated stud

NR,k tension VR,K: shear

[KN] [KN]

29.5 21.9

33.7 48.7

42.3 84.6

55.0 93.6

83.9 105.1

97.3 121.2

TECHNICAL DATA SHEET


Designation: HEAVY DUTY ANCHOR

Reference Date Revision Page Codes

FT SLV ingles 04.02.09 6 6 de 7 SLVT, SLVI, SLVE

1KN 100 Kg * The characteristic resistance of an anchor is that with a 95% probability to be achieved in a tension test. It depends on the mean ultimate resistance, the number of tests and the scatter of the results. ** Concrete C20/25 per ENV206: characteristic resistance for a specimen 28 days old: Cylindrical sample 150 mm. x 300 height 200 N/mm2 Cubic sample 150 mm. side 250 N/mm2

Underline and cursive values correspond to steel failure. Characteristic resistance for tension and shear must be considered separately. 6.2.- Recommended safety factors SAFETY COEFFICIENTS
Zinc yellow passivated bolt Tension Shear Zinc yellow passivated stud Tension Shear REDUCTION COEFFICIENT FOR RESISTANCES CONCRETE STEEL FAILURE FAILURE 1.5 1.5 1.5 1.5 1.5 1.25 -1.5 1.4 INCREASING COEFFICIENT FOR LOADS

6.3.- Calculation example Fixing a load tension of 4.000 kg 4.000 kg 40 KN Increasing coefficient for loads: Using two SLVT M12 anchors Pull load characteristic resistance for SLVT M12 anchor: Concrete failure Concrete reduction for resistances coefficient: Checking: increased load must be lower than reduced resistance 40 KN x 1.4 2 x 42.3 KN / 1.5 Wedges distance must be longer than 267 mm and distance to any edge must be longer than 134 mm as well. 7.- OFFICIAL DOCUMENTATION The official European Technical Approval document ETA 04/0100 for zinc yellow pasivated bolt version is available through our export department. 1.4 42.3 KN 1.5

TECHNICAL DATA SHEET


Designation: HEAVY DUTY ANCHOR

Reference Date Revision Page Codes

FT SLV ingles 04.02.09 6 7 de 7 SLVT, SLVI, SLVE

8.- EXAMPLES OF USE