Sei sulla pagina 1di 2

design of steel purlins

PROJECT : LOCATION: OWNER : SUBJECT : CODE: Date: Given

PROPOSED TWO STOREY RESIDENTIAL BLDG.

DESIGN OF PURLINS NSCP 1992 03/01/12 Height of truss Length of truss Spacing of truss Slope of roofing Spacing of purlins ht. of roof Wind zone Exposure category Importance factor. I Modulus of elasticity of steel Yield strength of steel Sag rods: Enter no. 2.00 10.50 1.20 0.38 0.60 3.50 II B 1.00 200.00 170.00 none 1.00 m. m. m. m. m. m. Normal loads, Wn: DL = LL = WL = 62.24136869 N/m 392.4848487 N/m 714.42 N/m

Tangential loads, Wt Gpa Mpa DL = LL = 23.7109976 N/m 149.5180376 N/m

Loads Dead loads: G.I. Roofing: Live loads: Wind loads Wind stagnation pressure,qs Combined Ht., exposure & Gust coefficient, Ce Pressure coefficient Cq Design wind pressure, P 77.00 Pa 700.00 Pa 2,700.00 Pa 0.63 0.70 =CeCqqsi 1,190.70 Pa 1.00 2.00

LOAD ANALYSIS Load case Wn (N/m) D+L 454.73 0.75( D+L+W) 876.86 FLEXURAL STRENGHT ( fbx ) Mpa Load case D+L 16.47 0.75( D+L+W) 31.76

Wt (N/m) 173.23 129.92

MO Mn (N-m) 81.85 157.83

1.00 2.00

( fby) Mpa 32.480444 24.360333

Check if co Fbx 138.00 138

Check for deflection Allowable deflection 6.67 mm = 0.64 mm

Trial section

LC 75x38x15x1.2 Yn = Weight = H= B= Tf = Ix = Iy = Sx = Sy = = 2.08 75 38 1.2 18.6 4.6 4.97 1.92 kg/m mm. mm. mm. Cm3 Cm3 Cm3 Cm3 5Wn L4 384EIx 5Wt L4 384EIy

SAFE SAFE

Yn =

0.51 mm

20.854458 Degrees

Page 1

design of steel purlins

Mt (N-m) 31.18 23.39 Remarks Load case Govern 0.38 safe case 2 0.43 safe case 2

Fby 123.60 123.60

Page 2

Potrebbero piacerti anche