Sei sulla pagina 1di 2

Dedicated power supply electrocoagulation

Information Dedicated power supply electrocoagulation Name: Published:2010-08-22 Validity:999 Specifications: Quantity:0.00 Price Negotiable Description: Detailed ProductElectrocoagulation Power Supply Description Chengdu Institute of Electrical Engineering Xindu Road and independent research and development DHEP series 24V/1000A electrocoagulation for power is the use of high frequency power electronic conversion technologies, specifically for the design and manufacture of sewage treatment for the power supply module. Performance indicators: Input voltage: Three-phase 380V 10% AC Output Characteristics: a: maximum rated output power: 24KW Output voltage range :0-24 .00 V Output current range :0.0-1000 .0 A b: stability Voltage precision: three-phase AC 380V 10% ,0-100% load current changes, the regulator output voltage does not exceed the accuracy of 1%. Steady flow accuracy: AC Three-phase 380V 10%, accuracy of the

steady flow of work during not more than 1%. C: noise voltage: peak noise voltage is not greater than 100mv. Ripple coefficient: coefficient of output voltage ripple is less than 1%. d: operating frequency: 20KHz Automatic limit; overcurrent protection, overvoltage protection and alarm functions; overheating protection and alarm functions weak control of the remote control interface and remote control functions; Built-in high-precision time control, automatic control of working time: 1 second -99 hours 59 seconds, and can be arbitrarily set within the 99H59M59S. Auto stop start function: When the drop in the electrolytic cell, the electrolysis time automatically start, after completion of the work setting, equipment, alarm and automatically limit the current (or voltage) to stop. regular working hours: working time in the forward and backward within the 1-999H can be set independently; Commutation interval: 3 seconds; Cooling: Air Cooled; anti-corrosion methods: full closure corrosion closed structure; Adjusting method: constant voltage regulator; Built-meter relay: count range :0-999H; reset mode: external reset button; display accuracy: 1%, (by the hour / minute / second = unit) Control: Time Control - off and time control - to open two; Start: Soft-start Operating environment conditions: Ambient temperature -10 - +40 ; Humidity: less than 90% (20 5 ); No flammable, explosive gases, not vibration Dimensions: 1600mm 600mm 400mm (can be customized according to customer demand)

Potrebbero piacerti anche