The current lightning protection standards recommend regular maintenance for lightning protection installations. The test period varies between 1 to 3 years according to equipment used. Tests and inspection is a tricky job because lightning conductors are generally located at higher levels than the buildings they protect.
Regular frequency Intensive frequency Level I Level II Level III 2 years 3 years 3 years 1 year 2 years 2 years

A UNIQUE SOLUTION
As a result of continued research and development in the field of Early Streamer Emission lightning rods, Hlita is able to offer a simple and comprehensive testing procedure : a portable test kit with 8 metre long telescopic pole to be used on site whilst in situ.

MA JOR ADVANTAGES
The test and inspection of the Pulsar without the need to remove the air terminal saves valuable time. It also eliminates risky manipulations at height. The Hlita kit brings you undisputed benefits in terms of efficiency with respect to the ESE standards.

IMPLEMENTATION
There should be a good contact between the tip of the Pulsar and the pole. The bottom of the telescopic rod is connected to the test unit. A second cable at the base of the test unit is then connected to a down conductor. The High Voltage block of the Pulsar is activated and the signal collected by the test unit. The good operating of the Pulsar guarantees the radius of protection calculation as per NFC 17 102 standards.

Description 8 metre control pole complete with tester

Reference PMH.0800

Installer / Dealer stamp

16, rue Bertin Poire 75001 PARIS France Tl : +(33) 01 45 08 47 47 Fax : +(33) 01 40 26 56 23 www.helita.fr e-mail : helita@club-internet.fr

PULSAR TESTER

Notice d'utilisation du testeur de Pulsar et de la perche de test PMH 0800 User notice for the Pulsar tester and for the PMH 0800 test pole Manual de utilizacon del aparato test de Pulsar y de la prtiga de test PMH 0800

F E ES E

HELITA - 16, rue Bertin Poire - 75001 PARIS Tl : +(33) 01 45 08 47 47 - Fax : +(33) 01 40 26 56 23 Telex : HELITA 213 983 F http://www.helita.fr - E-MAIL : helita@club-internet.fr

TEST POLE PMH 0800

PRESENTATION OF TESTER His appliance, called Pulsar tester or test case, is destined to test all the Pulsar models. To do this, the Pulsar must be put onto the plate of the case. This appliance can also be used with the test pole reference PMH 0800, and this without putting the Pulsar down.

earthing
TERRE EARTH

TESTEUR DE PULSAR PULSAR TESTER HPT 9211 CONNECTER ICI CONNECT HERE HT HV

HV test terminal HV presence indicator light charging circuit breaker test buttons

plate

COMMISSIONING THE TESTER The case is powered by two 9V type PP3 batteries in lithium. They are placed on the right side of the tester. PULSAR TEST - Put the Pulsar onto the brass plate. - Connect the yellow discharge-cord to the earthing. - Connect the upper part of the Pulsar to the HV test terminal using the red cord and the red testclip. - Put the charging plug on ON. - Push simultaneously a first time on the two test buttons to reset the device. - Push again simultaneously on the two test buttons. The HV presence indicator light turns on. The green indicator light turns on : the Pulsar is good. The green indicator light does no turn on : the Pulsar is defectuous. - Put the charging plug on OFF. - Discharge the Pulsar by touching the upper part of the Pulsar with the yellow cord.

OFF ON

TEST

PULSAR OK

TEST

green indicator light of good Pulsar operation

- Unplug the cords. RECOMMENDATIONS FOR USE The test terminal marked with a triangle warning delivers a tension of 1500V. This tension is not dangerous but avoid touching the upper part of the Pulsar during the test. Not to be used in rain. Not to be used outside the +5C +50C temprature range. USE WITH THE TEST POLE The PMH 0800 test pole allows testing a Pulsar without putting it down insofar as it is installed at least 8 metres from an accessible zone. In this case, the test pole is connected to the test terminal using the red test cord. The green-yellow test pole cord is connected on one side to the earthing of the tester, and on the other using the yellow clip to the descent of the Pulsar under test. The test pole not to be used in thunderstorms or rainy weather. The test pole not to be used if there is a risk of touching conductors under dangerous tension. MAINTENANCE The batteries are to be changed when the brightness of the HV presence indicator light feebles. Remove the batteries if the case is not used for a long time.

NOT TO BE USED IN PRESENCE OF LIVE CONDUCTORS

Clip to be connected to the earthing of the Pulsar and to the earthing of the case

Extrait notice B 8999 3024 ind.01