Case Study Infiltration Channel


Project Location Project Details Zayed University, ABU DHABI, United Arab Emirates Infiltration tank for University Campus
Start Date

February 2009

Proudly bearing the name of the founder of the nation - the late Sheikh Zayed bin Sultan Al Nahyan - Zayed University was founded in 1998 to inspire, encourage, educate, and lead a powerful generation of students. Zayed University is a public urban non-profit institute of higher education founded in 1998 that is located in Abu Dhabi, United Arab Emirates. The non co-educational university caters to both national and international students with undergraduate and graduate programs. The new campus is being built on 75 hectares at New Khalifa City near Abu Dhabi International Airport. When complete, the new campus will have a built-up area of 200,000 m2 and provide educational facilities for 6000 students. Completion is expected in July 2011. Atlantis products are being used as part of the stormwater system. Over 6.1km of infiltration channels or soakaways have been installed beside roads and pathways, providing over 4 million litres of storage. The channel system is constructed of thousands of Atlantis Matrix / D-Raintank - Double Modules wrapped in geotextile, placed in the channel two modules wide. Water from the impervious surfaces is stored in the modules and gradually allowed to percolate into the surrounding soil. The infiltration channels are sized to make sure that it doesnt overflow in severe storm events and to ensure that all the water is dissipated effectively into the surrounding area. A concrete sump has been provided a regular intervals to ensure that sand and vegetation matter cannot enter the infiltration channel. The project is being developed by Mubadala Development Company, which is wholly owned by the Abu Dhabi government and the main contractor for the stormwater is Al Habtoor Specon Hastie International, a joint venture between Al Habtoor Engineering and Hastie Group Limited.

ESTABLISHED IN 1986

The Atlantis Matrix tank (D-Raintank) assembled.

The Atlantis Matrix tank (D-Raintank) wrapped in Geotextile.

ESTABLISHED IN 1986

ESTABLISHED IN 1986

NOTES:

80mm NATURAL STONE PAVING INSIDE RECESSED COVER 600x600x130mm (CLEAR INTERNAL)

RECESSED MANHOLE COVER 600X600X130MM (CLEAR INTERNAL SIZE) OF STAINLESS STEEL OF GRADES 304 & 316 (TO BS 1449 PART-2) 80mm NATURAL STONE PAVING INSIDE

80 MM NATURAL STONE PAVING INSIDE RECESSED MANHOLE COVER

1. 2.

All dimensions are in millimeters unless specified otherwise. The grated slot inlet and its accessories are of RECYFIX STANDARD 100 by Hauraton or similar of Load Class 125KN. The grated slot inlet must have an intake cross section of 650cm/m length and must be galvanized. The Composite Channels system must meet the requirements of DIN EN 1433 or equivalent standards, and they must be suitable for loading capacity of CATEGORY B125, LOAD CLASS 125KN The Channel must have a width of 210mm and height of 192mm and is made up of PE-PP material or similar that satisfies the above noted standard.

3.

STEEL BAR MESH GRADE SRC (C20) CONCRETE


4.

600
5.

600

A
STIFFENING RIB

6.

The channels must have a built-in-fall to direct flow to opposite direction of the surface pavement flow when necessary. The last channel section, which is adjacent to the catch-basin, must be provided with vertical outlet at the bottom of the channel with diameter of 150mm for discharging the flow from the channel to the catch basin.

7.

50mm THK. CLASS M1 501:3 CEMENT & SAND MORTAR

100

8.

In lengthy grated-slot channel-runs of more than 20m length, an inline trash-box with plastic bucket and galvanized iron grating cover, Class B125, should be installed. Channel runs must be connected to catch basins either via trash boxes or end-caps with horizontal uPVC outlet, including the necessary bends to vertically align the connection to the required invert level at the catch basin. The adjoining surface finishes shall be laid to finish permanently 3mm higher than the top edge of the channel. The surfaces to be bonded have to be sufficiently firm, dry, clean and free from oil and grease to ensure that bonding and curing is not adversely affected.

DOUBLE SEAL (FILLED-IN WITH DENSO MANHOLE SEALING GREASE OR EQUIVALENT)

9.

NATURAL STONE PAVING CUT TO FIT SLOT DRAIN OPENING

10.

DETAIL 1
PLAN AT COVER LEVEL
SEE DETAIL 1

11.

SCALE 1:3

80mm NATURAL STONE PAVING


INSIDE RECESSED COVER

RECESSED MANHOLE COVER 600X600X130MM (CLEAR INTERNAL SIZE) OF STAINLESS STEEL OF GRADES 304 & 316 (TO BS 1449 PART-2) 80mm NATURAL STONE PAVING INSIDE RECESSED COVER

80mm NATURAL STONE PAVING INSIDE RECESSED COVER

RECESSED MANHOLE COVER 600X600X130MM (CLEAR INTERNAL SIZE) OF STAINLESS STEEL OF GRADES 304 & 316 (TO BS 1449 PART-2) 80mm NATURAL STONE PAVING INSIDE RECESSED COVER

50mm THK CLASS M1 1:3 CEMENT & SAND MORTAR

50mm THK CLASS M1 1:3 CEMENT & SAND MORTAR

600

600

Nov-2008

FIRST ISSUE

150

800 MIN

200

STIFFENING RIB SUPPLIED WITH COVER 150 uPVC PIPE FROM GRATED SLOT or SLOT OPENING

150

STIFFENING RIB SUPPLIED WITH COVER 150 uPVC PIPE FROM GRATED SLOT or SLOT OPENING

VARIES

300 VC PIPE WATERPROFFING MEMBRANE ACCORDING TO QCS 2007 (SECTION 5, CLAUSE 14.3)

WATERPROFFING MEMBRANE ACCORDING TO QCS 2007 (SECTION 5, CLAUSE 14.3)

300 VC PIPE APROVED SEALANT 300 VC PIPE OUTFLOWING TO EXISTING MANHOLE

250

GRADE OPC 35 REINFORCED CONCRETE

250

300 VC PIPEPIPE INCOMING FROM UPSTREAM CATCH BASIN

GRADE OPC 35 REINFORCED CONCRETE

200

100mm THK GRADE SRC 20 CONCRETE BLINDING

100mm THK GRADE SRC 20 CONCRETE BLINDING

200

100

150

800

150

100

100

150

800

150

100

SECTION A-A
10
XX

SECTION B-B
TYPICAL CATCH BASIN WITH RECESSED TRAY COVER
SCALE: 1:10 @A1

STORM WATER CATCH BASIN DETAIL DRAWINGS


1:10 @ A1

ESTABLISHED IN 1986

Distributor: ATLANTIS WATER MANAGEMENT


Note: Atlantis products are manufactured from high quality recycled materials, carefully selected and under strict quality control procedures. The strength could vary slightly due to raw material, country of manufacture, manufacturing process and external conditions. Safety Factors: Engineers, designers and geotechnical engineers should design and calculate safety factors to a serviceable limited state to suit specific project. In case of doubt, consult your nearest distributor or Atlantis representative. Disclaimer: All information provided in this publication is correct to the best knowledge of the company and is given out in good faith. This information is intended only as a general guide, no responsibility can be accepted for any errors, omissions or incorrect assumption. As each project is unique, and as Rebirth Pty Ltd, Atlantis Water Management, Atlantis Corporation Pty Ltd and its distributors and agents world wide have no direct control over the methods employed by the user in specifying, installing or supervising of its products hence no responsibility is accepted by Rebirth Pty Ltd, Atlantis Water Management, Atlantis Corporation Pty Ltd and its distributors and agents world wide. Users should satisfy themselves as to the suitability of the product for their purpose. All product designs, and specification are subject to change without further notice. All Atlantis products are tested in approved NATA laboratories, and safe allowed tolerances should be practised in the actual field, to compensate for any unforeseen situations, on site and on products. All material contained within this brochure is subject to copyright, and belongs to Rebirth Pty Ltd Australia. No part of this brochure may be reproduced or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without prior written permission of Rebirth Pty Ltd. Australia, Atlantis Water Management, Atlantis Corporation Pty Ltd. Copyright @ 2009 by Rebirth Pty Ltd. Australia, Atlantis Water Management, Atlantis Corporation Pty Ltd. Australia. 2009 - 0.1/1 - Zayed University, ABU DHABI, United Arab Emirates

HEAD OFFICE: 3/19-21 Gibbes Street, Chatswood, NSW 2067, Australia PHONE: + 612 9417 8344 FAX: + 612 9417 8311 AUSTRALIA WIDE PHONE NO.: 1300 38 28 38 EMAIL: info@atlantiscorp.com.au WEB: www.atlantiscorp.com.au Atlantis Water Management Victoria 30 Venture Drive, Sunshine, VIC 3020 Australia PHONE: 1300 38 28 38

Atlantis Water Management

Agent: