Sei sulla pagina 1di 8

Technical Bulletin SERIES 14

TAB Series 14 -03/03


Single Seated Globe Valve for
Ratings ANSI 150-600

Features

General

Designed to ensure it represents a cost


effective solution to a variety of process
control applications, the construction of this
range of valve is of a simple form allowing
rapid assembly and high interchangeability of
trims.

Performance:
— High flow capacity.
— Tight shut-off.
— Excellent flow control rangeability.
— Low weight.
— Streamline flow passages to improve
capacity.

Design Flexibility:
— Inherent Modified Equal Percentage trim,
with options for equal percentage and
linear from characterised positioner.
— Clamped guide and seat allows quick
change for modification/service.
— High interchangeability of trim components
and soft parts.

Design Integrity:
— Optimised using computer aided analysis.
— Designed to ASME B16.34
— High integrity precision cast components.

Quality Manufacturing:
— Rigorously tested to ensure specified
performance on site.
— Quality Assurance systems certified to ISO
9001
— NACE MR-01-75 certification.
Single Seated Globe Valve
Series 14 ABB Series14 -10/02

Scope of Design Temperature Range:

End Connection Sizes:


1” to 4” (25mm to 100mm)

End Connection Styles:


ANSI Flanged RF,
Butt Weld & Socket.

Valve Body Ratings: Actuation:


ANSI 150 to ANSI 600. Multispring style Series ‘H’
actuators, available in 55in2, 110in2 & 220in2 as standard.
Bonnet Packings: ‘G’ Series actuator available as an option.
Teflon Chevron for standard duty.
Flexigraph for high temperatures.
Sizing/Noise:
The procedures for performing valve sizing, velocity
Body Material Options: and sound pressure level calculations are detailed
ASTM A216 Gr WCB
in the Technical Sizing and Selection Manual.
ASTM A351 CF8M

Design Standards:
ASME B16.34
IEC 534.3-1

Temperature Related Features


The Table below gives a general guide to the limitations of various design features when associated with temperature.

Table 1. Temperature related features

2
Single Seated Globe Valve
Series 14 ABB Series 14 -10/02

Design Cv Values
The design Cv values detailed below are defined as the flow of water (SG=1) through the valve at full lift in US gallons
per minute with a pressure drop of 1psi.

Table 2. Design Cv Values

3
Single Seated Globe Valve
Series 14 ABB Series14 -10/02

Guide to Trim Options Available Figure 1. Contoured Trim

Standard Duty
For standard duty applications there is the option of
Contoured trim (Figure 1) or
Cage Guided trim (Figures 2 and 3)

Trim Design Options:


Contoured & Cage Guided trims have Full and reduced
trim capacity.

Characteristics Available:
Inherent Modified Equal Percentage (Equal Percentage
& Linear available with characterised positioner)

Plug Options: Figure 2. High Friction Cage Trim illustrated with Balanced
Unbalanced Contoured Trim. Plug

Unbalanced Cage Guided (1” to 4” Valves) or


Balanced Metal/Metal Cage Guided (1.1/2” to 4” valves)
with Resilient or Graphite piston rings.
Soft seats are available for bubble tight shut off.

Direction of Flow:
Recommended flow under for both liquids and gas of
Contoured trims.
Flow over the plug for liquids & flow under for gases of
Cage Guided trims.

Severe Duty:
The High Friction (HF) trims are suitable for high Figure 3. High Friction HF trim illustrated with Solid Plug

pressure drop applications to prevent the onset of


cavitation and reduce the noise levels generated as the
result of both gas/vapour and liquid flows.

4
Single Seated Globe Valve
Series 14 ABB Series 14 -10/02

General Selection information


The information detailed is intended to act as a general guide, to assist in the selection of a Series 14 Valve

Trim Cv Calculation
A full set of procedures for calculating the Cv with various fluids is detailed in the Sizing and Selection Manual.
Please contact the nearest Sales Office for your copy.

Body Selection
The valve body must be capable of supporting the selected trim without producing excessive velocities. The following
tables can be used as a guide for determining the maximum recommended body velocities for both liquid and gas/
vapour applications.

Liquid Service
The velocities detailed in Table 3. below reflect the normal inlet and outlet maximum velocities recommended to
eliminate body erosion and prevent trim instability. Other factors may reduce the following figures further.
Refer to Sizing and Selection Manual for further details.
Table 3. Recommended maximum inlet and Outlet Velocities Liquid Service

Gas/Vapour Service
These velocities avoid problems of vibration and body erosion. Where noise levels are a consideration velocities
should be restricted to the relevant Mach numbers.

Table 4. Recommended maximum inlet and Outlet Velocities Gas/Vapour Service

Trim Inherent Rangeability


The inherent rangeability of a valve trim is dependant on a number of factors including size and style. The values
detailed in Table 5. provide a general guideline to the maximum achievable values.
Table 5. Maximum Inherent Rangeability

5
Single Seated Globe Valve
Series 14 ABB Series14 -10/02

Figure 4. Inherent Flow Characteristic Figure 5. Optional Flow Characteristics

Inherent Flow Characteristic Optional Flow Characteristics*


The inherent flow characteristic of a control valve is the The optional flow characteristic is the relationship
relationship between the flow and the valve travel at between the flow and the control signal at constant
constant pressure drop. pressure drop.
*Available only with positioner

Maximum Leakage Rates


Leakage rates are normally measured in accordance with the ANSI/FCI 70-2-1976 specification using the class
designation.
The following Table 6. defines the achievable leakage class for each available plug designs.

Table 6. Achievable Leakage Class

Note: (STD) or (SPL) refer to the amount of seat/plug lapping carried out at final assembly.

6
Single Seated Globe Valve
Series 14 ABB Series 14 -10/02

Table 7. Actuator Dimensions

Note:
1.Face to face dimensions comply with IEC 534.3-1
2.ABB Control Valves reserve the right to confirm
dimensions on certified drawings
*For other Valve/Actuator combinations, please consult
factory
Table 8. Valve Dimensions

Table 9. Valve Estimated Weights

7
Single Seated Globe Valve
Series 14 ABB Series14 -10/02

www.abb.com/controlvalves The Company’s policy is one of continuous product


improvement and the right is reserved to modify the
specifications contained herein without notice.
Printed in UK (10.02)
© ABB 2002

ABB Control Valves UK ABB Control Valves - India


Issue 4

Kent Introl Ltd Introl (India) Ltd


Armytage Road, H-34, MIDC, Ambad
West Yorkshire Nashik 422 010
Series14/03/03

England HD6 1QF India


Tel: +44 (0)1484 710311 Tel: +91 253 381434
Fax: +44 (0)1484 407407 Fax: +91 253 384413