Back 3OC + 1EF Numerical Relay : General Description : ADR241B

The ADR241B is multifunction over current / Earth fault Numerical relay design for requirement of typical medium voltage feeder. All the relay are designed using latest numerical technology and having programmable digital input and outputs to minimized external contact multiplication electromechanical relays. All relays are tested for EMI / EMC noise as per international IEC specifications. General features of all relays are as given below 3 stages of 3Io (Internally derived EF) (3Io>, 3Io>> and 3Io>>>) (50N,51N). 3 stages of Ie (Externally EF or REF) (Ie>, Ie>> and Ie>>>) (64). Trip Circuit Supervision.(TC) Breaker Failure Detection.(BF) Monitoring Functions. Auto Reclose Relay (ARR).(79) Negative Phase Sequence.(46) Relay / Led configuration. Specifications : 4 Element (3 Phase + EF + Sensitive EF) Over current IDMT/DMT with instant trip. Selection of Curve: Five selectable curve (Normal Inverse 1 Normal Inverse 2, Very Inverse Extremely Inverse Long Time Inverse and Define Time. 2 Setting Groups. 4 stages of Phase Over Current element. (Ip1>, Ip2>, Ip>> and Ip>>>) (50,51). Large 20x4 LCD display for Parameter and setting display. Disturbance Recorder. Up 3 sec Fully communicable with IEC standard open protocol. IEC60870-5-103 (RS232C and RS485) 6 Digital Output (DO) and 8 Optically isolated digital status input (DI) Programmable Logic of DI/DO. 100 nos of event memory, 10 nos of Fault data stored with keypad interface and time stamping.

Back Numerical 3 OC & 1 EF Switchgear Protection Relay : General Description : ADR141A

The ADR141A is a 3 OC and 1 EF Switchgear Protection relay with Instantaneous high set and programmable output to simplify feeder protection wiring. ANSI 50 50N 51 51N IEC I >> IE>> I>t, Ip IE>t, IEP Protection Functions Instantaneous Over current Protection (OC-Inst.) Instantaneous Earth Fault Protection (EF-Inst.) Time Over current Protection (Phase) (OC-IDMT.) Time Over current Protection (Earth) (EF-IDMT.) Specifications : 4 Element (3 Phase + EF) over current IDMT with instant trip. Display of fault current. / Load current. Selection of Curve: Six selectable curves (Normal Inverse1 (C1), Normal Inverse2 (C2), Very Inverse (C3), Extremely Inverse (C4), Long Time Inverse (C5) & Definite Time (C6). Separate curve selection for phase and EF. Latching of fault current up-to last 5 fault. Site selectable CT secondary Programmable Annunciation Contact Trip circuit supervision function. Breaker Fail. Model Functional Details Cabinet Style

Back Numerical Communicable OC/EF Protection Relay : General Description : ADR131A

The ADR131A is a three element numerical relay can having following option , 2 OC +1 EF or 3EF relay with Instantaneous high set and programmable output to simplify feeder protection wiring. ANSI 50 50N 51 51N Protection Functions Instantaneous Over current Protection (OC-Inst.) Instantaneous Earth Fault Protection (EF-Inst.) Time Over current Protection (Phase) (OC-IDMT.) Time Over current Protection (Earth) (EF-IDMT.) Specifications : 3 Element (2 Phase + EF / 3 Phase / 3EF ) over current IDMT with instant trip. Display of fault current. / Load current. Selection of Curve: Six selectable curves (Normal Inverse1 (C1), Normal Inverse2 (C2), Very Inverse (C3), Extremely Inverse (C4), Long Time Inverse (C5) & Definite Time (C6). Separate curve selection for phase and EF. Latching of fault current up-to last 5 fault. Site selectable CT secondary Programmable Annunciation Contact Trip circuit supervision function. Breaker Fail.

Model

Functional Details

Cabinet Style

Numerical 3OC + 1EF Medium Voltage Protection Relay : General Description :

Back ADR141C

The ADR141C is a 3 OC and 1 EF Medium Voltage Protection relay with Instantaneous high set and programmable output design in very compact cabinet. ANSI 50 50N 51 51N Protection Functions Instantaneous Over current Protection (OC-Inst.) Instantaneous Earth Fault Protection (EF-Inst.) Time Over current Protection (Phase) (OC-IDMT.) Time Over current Protection (Earth) (EF-IDMT.) Specifications : 4 Element (3 Phase + EF) over current IDMT with instant trip. Display of fault current. / Load current. Selection of Curve: Six selectable curves (Normal Inverse1 (C1), Normal Inverse2 (C2), Very Inverse (C3), Extremely Inverse (C4), Long Time Inverse (C5) & Definite Time (C6). Separate curve selection for phase and EF. Latching of fault current up-to last 5 fault. Site selectable CT secondary Programmable Annunciation Contact Trip circuit supervision. Model Functional Details Cabinet Style

Numerical Directional 3OC + 1EF Feeder Protection Relay : General Description :

ADR245B

The ADR245B is multifunction complete feeder protection relay (directional over current / Earth fault) relay design for requirement of typical medium voltage feeder. All the relay are designed using latest numerical technology and having programmable digital input and outputs to minimized external contact multiplication electromechanical relays. All relays are tested for EMI / EMC noise as per international IEC specifications. General features of all relays are as given below 3 stages of Directional / Non Directional 3Io (Internally derived EF) (3Io>, 3Io>> and 3Io>>>).(50N,51N,67N). 3 stages of Directional / Non Directional Ie (Externally EF or REF) (Ie>, Ie>> and Ie>>>).(64,67N). Under Voltage (27) Over Voltage (59) Neutral Voltage Displacement (59N). Trip Circuit Supervision.(TC). Specifications : 4 Element (3 Phase + EF + Sensitive EF) Directional Over current IDMT/DMT with instant trip. Selection of Curve: Five selectable curve (Normal Inverse 1 Normal Inverse 2, Very Inverse Extremely Inverse Long Time Inverse and Define Time. 2 Setting Groups. 4 stages of Phase Directional / Non Directional Over Current element. (Ip1>, Ip2>, Ip>> and Ip>>>). (50,51,67). 100 nos of event memory, 10 nos of Fault data stored with keypad interface and time stamping. Breaker Failure Detection.(BF). Monitoring Functions. Auto Recloser Relay (ARR).(79) Negative Phase Sequence.(46). Relay / Led configuration. Large 20x4 LCD display for Parameter and setting display. Disturbance Recorder. Up 3 sec. Fully communicable with IEC standard open protocol. IEC60870-5-103 (RS232C and RS485). 6 Digital Output (DO) and 8 Optically isolated digital status input (DI). Programmable Logic of DI/DO Display of Voltage, current, PF, Active, Reactive Power in terms of primary value.

Back Numerical Communicable OC/EF Protection Relay : General Description : ADR241A

The ADR241A is communicable 3 OC and 1 EF relay with Instantaneous high set and programmable output to simplify feeder protection wiring. ANSI 50 50N 51 51N Protection Functions Instantaneous Over current Protection (OC-Inst.) Instantaneous Earth Fault Protection (EF-Inst.) Time Over current Protection (Phase) (OC-IDMT.) Time Over current Protection (Earth) (EF-IDMT.) Specifications : 4 Element (3 Phase + EF) over current IDMT with instant trip. Display of fault current. / Load current. Selection of Curve: Six selectable curves (Normal Inverse1 (C1), Normal Inverse2 (C2), Very Inverse (C3), Extremely Inverse (C4), Long Time Inverse (C5) & Definite Time (C6). Separate curve selection for phase and EF. Latching of fault current up-to last 5 fault. Site selectable CT secondary Programmable Annunciation Contact Trip circuit supervision function. Breaker Fail. SCADA compatibility. IEC60870-5-103 protocol.

Back Numerical Communicable OC/EF Protection Relay : General Description : ADR231A

The ADR231A is a three element communicable numerical relay can having following option , 2 OC +1 EF or 3EF relay with Instantaneous high set and programmable output to simplify feeder protection wiring. ANSI 50 50N 51 51N Protection Functions Instantaneous Over current Protection (OC-Inst.) Instantaneous Earth Fault Protection (EF-Inst.) Time Over current Protection (Phase) (OC-IDMT.) Time Over current Protection (Earth) (EF-IDMT.) Specifications : 3 Element (2 Phase + EF / 3 Phase / 3EF ) over current IDMT with instant trip. Display of fault current. / Load current. Selection of Curve: Six selectable curves (Normal Inverse1 (C1), Normal Inverse2 (C2), Very Inverse (C3), Extremely Inverse (C4), Long Time Inverse (C5) & Definite Time (C6). Separate curve selection for phase and EF. Latching of fault current up-to last 5 fault. Site selectable CT secondary Programmable Annunciation Contact Trip circuit supervision function. Breaker Fail. RS232C and RS485 Communication port.