SPECIFICATION FEATURES 1 ASTM Grade steel base plate with ASTM A366 base cover. 2 Hand hole assembly 3" x 5" on SRT poles. 3 Steel shaft minimum yield 55,000 PSI. Shot blasted and painted with premium TGIC polyester powder coat. 4 Drilled or Tenon (specify). 5 Anchor bolt per ASTM A576 with (2) nuts, (2) flat washer, and (1) lock washer. Nuts, washers and threaded portion of bolt are hot dip galvanized. 3" hook for 3/4" bolt. 4" hook for 1" bolt.
3
Mounting Height (MH)
DRILL PATTERN Single w/Arm [1] 0.69 1.09 0.71 1.11 1.27 1.6 1.28 1.82 0.85 1.35 1.03 1.64 1.15 2.1
EPA + MOUNTING CONFIGURATIONS 2 @ 180 [2] 1.38 2.18 1.42 2.22 2.54 3.20 2.56 3.64 1.70 2.70 2.06 3.28 2.30 4.20 2 @ 90 [5] 1.38 2.18 1.42 2.22 2.54 3.20 2.56 3.64 1.70 2.70 2.06 3.28 2.30 4.20 3 @ 90 [3] 1.84 2.86 1.90 2.92 3.60 4.50 3.63 4.96 2.35 3.83 2.89 4.70 3.20 6.00 3 @ 120 [6] 1.84 2.86 1.90 2.92 3.60 4.50 3.63 4.96 2.35 3.83 2.89 4.70 3.20 6.00 4 @ 90 [4] 2.07 3.20 2.14 3.27 4.13 5.55 4.17 5.62 2.68 4.56 3.49 5.77 3.81 7.50
PRODUCT ICON SMALL ICON MEDIUM ICON SMALL STRUCTURAL MOUNT ICON MEDIUM STRUCTURAL MOUNT VISION SMALL
TENON A C J K E M F G A C A C E M
2
Hand Hole 12 5/16"
1
B
VISION MEDIUM STRUCTURAL MOUNT ASCENT SMALL ASCENT MEDIUM STRUT SMALL STRUT MEDIUM
Base View S BC
D BP
5
AB
H=Bolt Dimensions
www.cooperlighting.com
Specifications and dimensions subject to change without notice. Consult your representative for additional options and finishes.
AVU082205
The following information illustrates the correct way to enter an order for SRT8A30SGMA2G. The ordering designation is detailed as follows.
Shaft 3 Size 8 Wall Thickness A Mounting Height (ft.) 30 Base Type S Fixture Mounting + Type A No. + Location of Arms 2 Accessories (Ground Lug) G
Steel S
Round R
Tapered T
Colors GM
Mtg. Height MH 20 25 30 35 35 39 39
Base Square (In.) S 10 1/2 10 1/2 12 1/2 12 1/2 12 1/2 12 1/2 12 1/2
Bolt Circle Dia. (In.) BC 11.0 11.0 12.5 12.5 12.5 12.5 12.5
Shaft Size (In.) B 6.3 x 3.5 7.0 x 3.5 7.7 x 3.5 8.4 x 3.5 8.4 x 3.5 8.9 x 3.5 8.9 x 3.5
Net. Wt. (Lbs.) 173 214 290 342 482 341 536
EPA (Sq. Ft.) 4 At Pole Top 70 80 90 29.8 22.7 17.8 28.1 21.4 16.7 24.0 18.2 14.2 23.0 17.3 13.5 38.9 29.6 23.2 21.5 16.2 12.4 38.2 29.0 22.5
EPA (Sq. Ft.) 4 2' Above Pole Top 70 80 90 100 27.1 20.6 16.2 13.1 26.0 19.8 15.5 12.5 22.5 17.0 13.3 10.6 21.7 16.4 12.7 9.9 36.8 28.0 21.9 17.3 20.5 15.4 11.8 9.0 36.4 27.6 21.4 16.8
Max. Fixture LoadInclude Bracket (Lbs.) 400 400 400 400 400 400 400
NOTES: 1 Catalog number includes pole with anchor bolts with double nuts. (BEFORE INSTALLING ANCHOR BOLTS MAKE SURE PROPER ANCHOR BOLT TEMPLATE IS OBTAINED FROM COOPER LIGHTING). 2 Tenon size or machining for rectangular arms must be specified. Hand hole is located 180 from single arm. 3 Shaft size, base plate, anchor bolts and projections may vary slightlyall dimensions nominal. 4 EPAs based on shaft properties with wind normal to flat. EPAs calculated using base wind velocity as indicated plus 30% gust factor. 5 Two piece pole. Shipped in two sections and is easily joined together at the job site by slip-fitting together.
MOUNTING OPTIONS=FIXED Designation O.D. Number (in.) 1 2 3/8" 2 2 3/8" 3 3 1/2" 5 3"
TENON [add as suffix] Length O.D. (in.) 3 1/2" 4" 5" 4"
LENGTH
ACCESSORIES A=1/2" Tapped Hub 1 B=3/4" Tapped Hub 1 C=Convenience Outlet 2 G=Grounding Lug (Max. Wire #8 AWG) H=Additional Hand Hole and Cover (12" Below Pole Top90 from Hand Hole) NOTES: 1 Location is 3' above base 90 from hand hole. 2 Outlet is located 4' above base and on same side of pole as hand hole, unless specified otherwise. Receptacle not included, provision only.
(TYPE C)
(TYPE J)
.312'' [8 mm] dia. hole
(TYPE K)
.312'' [8 mm] dia. hole 2 3/4" [70 mm] 16 3/8" [416 mm] 3/4'' [20 mm] dia. holes 3" [77 mm] 1 1/2" [39 mm] (2) 9/16'' [15 mm] dia. holes
2 1/8" [54 mm] 3/4'' [20 mm] dia. hole 2 1/2'' [64 mm] 1 1/4'' [32 mm] (2) 3/8'' [10 mm] dia. holes
2 1/8" [54 mm] 3/4'' [20 mm] dia. hole 3'' [77 mm] 1 1/2'' [39 mm] (2) 9/16'' [15 mm] dia. holes
2 3/4" [70 mm] 12 23/32" [322 mm] 3/4'' [20 mm] dia. holes 2 1/2" [64 mm] 1 1/4" [32 mm] (2) 3/8'' [10 mm] dia. holes
(TYPE E)
(TYPE M)
(TYPE F)
.312'' [8 mm] dia. hole
(TYPE G)
.312'' [8 mm] dia. hole 2 3/4" [70 mm] 15 7/8" [405 mm] 3/4'' [20 mm] dia. holes 4 7/8" [124 mm] 2 7/16" [62 mm] (2) 9/16'' [15 mm] dia. holes
2 13/16'' [71 mm] 3/4'' [20 mm] dia. hole 7/8'' [23 mm] 3 7/8'' [99 mm] (2) 3/8" [10 mm] dia. holes
2 5/16'' [59 mm] 3/4'' [20 mm] dia. hole 2 7/16'' [124 mm] 4 7/8'' [124 mm] (2) 5/8'' [16 mm] dia. holes
2 3/4" [70 mm] 11" [280 mm] 3/4'' [20 mm] dia. holes 3 7/8" [99 mm] 3" [77 mm] (2) 3/8'' [10 mm] dia. holes
Single
2 @180
3 @ 90
4 @ 90
2 @ 90
3 @ 120
2 @ 120
CAUTION: Cooper Lighting poles have been designed to support only the luminaires and equipment originally intended. Miscellaneous items such as pennants, signs, and decorations may cause pole failure because of overloading. Addition of these items voids The Cooper Lighting warranty. Cooper Lighting will, however, supply information regarding total loading capacity on request. Cooper Lighting poles are guaranteed only when used in a pole/luminaire or floodlight combination. Any other application of poles, including application without a luminaire or floodlight, voids Cooper Lightings warranty.