Wrtsil addresses these demands with its Combined Heat and Power (CHP) solutions for utilities, IPPs, industry and municipalities. Typical plant sizes range from 4 to100 MWe, in single or multi-engine configurations. The combination of high efficiency and low emissions offered by Wrtsil CHP plants is unequalled in the market. Wrtsil engines as such comply with various national and local environmental requirements and with World Bank guidelines for power plants. Cogeneration is a closed process that requires no auxiliary cooling of the engines since the heat from the process is taken into profitable use. CHP plants, with their unbeatable electrical efficiency and high total efficiency throughout the load range, have very low CO2 emissions, so they easily comply with the most stringent environmental and CHP regulations. Wrtsil CHP plants can run on various grades of natural gas and liquid fuel, while still maintaining low emissions and high efficiency. The plants include thermal heat recovery for hot water, steam, direct-fire hot air, or chilled water raising an already efficient power plant, 43-45% in terms of net electricity, to a total efficiency of 90% or above. More efficient use of fuel also translates into lower emissions per unit of fuel.
800
750 600
670
240
2)
PISTICCI, ITALY Type of customer ...........Industry - IPP Engine type....... 4 x Wrtsil 18V34SG Total electrical output...............22 MW Total heat output ...................17.3 MW Total efficiency............................ 74%
PLANT CONCEPT
Wrtsil CHP plants powered by reciprocating engines offer flexibility and uncompromising performance wherever power and heat are required. Wrtsils gas and diesel engines have by far the highest electrical efficiency for prime movers in the market. The exhaust gases and cooling water from the engine can flexibly be utilized for numerous applications as low-pressure steam for industrial entities, as district heating and/or chilled water for cities, office complexes and municipalities; or the exhaust gases can be used directly for drying, etc. Depending on customer needs, the CHP plants total efficiency can even exceed 90 %. Typical heat recovery systems, between the prime mover and the customers equipment, are of hang-on type and ensure both optimized heat production and effective engine cooling and operation. Wrtsils heat recovery design takes into account all the customers seasonal, monthly, weekly and daily variations in running and operational heat production conditions. Heat production does not affect the electrical output or the electrical efficiency of the prime mover. The modular design of Wrtsil CHP plants enables rapid delivery anywhere in the world. Prefabricated, functionally pre-tested modules guarantee consistent quality and performance
4
and make on-site installation a matter of assembling and connecting the modules. Wrtsil has the resources and capabilities to carry out deliveries ranging from the supply of equipment and engineering to complete turnkey projects including engineering, procurement and construction. A globally experienced project organization guarantees successfully executed deliveries around the world. One of the benefits of Wrtsils modular plant concept is the unique flexibility of
operation enabled by the cascading multiengine structure of the plants. Multi-unit installations provide load flexibility: extra generating sets can be turned off, while the plant continues to run at peak efficiency with as many units as required. As needs change, the design of the plants makes it possible to increase the plant size in stages by adding new engines. This also allows for a smaller initial investment with the option to expand later as required.
CHP module
Wrtsil 20V34SG
Pre-engineered and pretested modules minimizes construction time and maximize reliability.
MONOPOLI, ITALY
Engines: 6 x Wrtsil 18V46 + Steam turbine Output: 100 MWe (engines) + 11 MWe (turbine) Fuel: Liquid biofuel (mainly palm oil) Emission control: SCR NOX abatement
+10,950
Engine-generator set
Radiator +15,500
CHP-module 22,500
Engine-generator set
capacity or temperature in the industrial process or the district heating network. Such a plant is very suitable when all the heat and power it produces can be used for either heat or processing purposes. To optimize the balance between thermal and electrical energy production, each plant is customized to suit the needs of the end user. Whether it is hot water for district heating,
industrial process steam or even chilled water, Wrtsil provides a design that ensures maximum efficiency and the best possible overall solution. The automation system not only controls all the internal processes in the Wrtsil CHP plant but is also carefully integrated with all necessary signals and connections to existing systems to guarantee a fully compatible plant.
POWERFUL CHOICES
The high efficiency of Wrtsils CHP plants translates into considerable savings in fuel costs compared to other technologies. For optimized balance and profitability, the plants are customized to the customers specific needs. A decentralized combined heat and power plant increases the reliability of energy supply in the neighbourhood. Total energy production is local and close to the point of consumption. Local heat generation ensures a quick response to changes in
Steam consumer Electricity Steam generator
CAC 1 and 2
Electricity
Burner
CAC 1 and 2
UJPALOTA, HUNGARY Type of customer ...........................IPP Engine type....... 3 x Wrtsil 20V34SG Total electrical output.............20 MWe Total heat output ................19.2 MWth Total efficiency......................... 84.6%
7 C
TRI-GENERATION
Typical tri-generation solution for airports
95-105 C 1-stage absorption chiller Chilled water or district cooling 12 C
70-105 C CAC1/ jacket water Hot water or district heating Lube oil cooler 45-55 C Circulation pump
RINGKBING, DENMARK: Type of customer ....................... Utility Engine type....... 1 x Wrtsil 20V34SG Total electrical output..............7.9 MW Total heat output .....................9.7 MW Total efficiency....................... 96.45%
SG operation
Dual-fuel operation
GD operation
Diesel operation
1.05
Derating due to cooling water temperature. (Derating due to inlet air temperature starts at 45 C)
Derating factor
15
20
25
30
35
40
45
ENGINE TECHNOLOGY
A reciprocating engine is the most efficient means of converting liquid or gaseous fuels into energy. The Wrtsil CHP plant can run on most natural gas types, heavy and light fuel oils, and emulsified fuels. Dual-fuel engines give added reliability to the CHP plant, since they can use whichever fuel is available at the lowest cost. The heart of Wrtsils generating sets is Wrtsils reliable engine technology, the result of long experience of demanding marine and power plant applications. All Wrtsil engines have a simple and straightforward modern design with facilities for easy and rapid on-site maintenance.
CUSTOMER CARE
Wrtsils aim is to ensure that customers obtain the best possible performance from their power plant investment throughout its lifecycle. After all, who could be better at this than the people who designed and built the plant? Wrtsil provides a comprehensive range of services built on the concept of enhancing the customers profitability by optimizing all aspects of the power plant operation. The services range from rapid spare parts delivery to a complete operation and maintenance partnership, allowing the customer to focus on their core business.
10
Wrtsil Operations & Maintenance currently runs more than 130 plants around the world, making it the worlds leading power plant O&M contractor. If customers choose to operate the plant themselves, they can still rest assured that they have the best possible support available as and when needed from training and on-line support to service packages or plant modernization and upgrading. Wrtsils global network is always ready to make sure the power plant performs flawlessly, free of breakdowns and unwanted downtime throughout its lifetime.
GYR, HUNGARY Type of customer ............. Municipality Engine type....... 3 x Wrtsil 18V34SG Total electrical output.............19 MWe Total heat output ................16.4 MWth Total efficiency......................... 82.9% 11
Exhaust stacks
Cooling radiators
Engine generator set Module for hot water generation Engine exhaust outlet District heating pump Feed and return for district 13
14
Performance data as guidelines for CHP calculations Wrtsil gas fuelled generating sets at 50 and 60 Hz
Performance data Engine Wrtsil gas engines at frequency 50 Hz 9L34SG 16V34SG 20V34SG Gas mode 20V34DF 18V50DF Wrtsil gas engines at frequency 60 Hz 9L34SG 16V34SG 20V34SG 20V34DF 18V50DF Liquid fuel mode 2000*
Engine optimization: NOX (dry @ 15 vol-% O2) Electric power Heat rate 1) Efficiency 1) Cooling circuit inlet/outlet 2) HTCAC temperature inlet/outlet Cylinder temperature inlet/outlet Lubrication oil circuit inlet/outlet LTCAC temperature inlet/outlet Charge air flow Exhaust gas flow Exhaust gas temp. Exhaust gas energy Cooling circuit-energy HTCAC energy Lubrication oil energy LTCAC energy Heat losses by radiation 5% 5% 15
Liquid Liquid Liquid Gas Gas Gas fuel fuel fuel mode mode mode mode mode mode 14602000* (LFO) 14602000* (LFO) mg/Nm3 95190* 95190* 95190* 190380* 190380* 2000* 95190* 95190* 95190* 190380* 190380* 16002000 (HFO) 16002000 (HFO) kW kJ/kWh % C C C C C kg/s kg/s C 3888 7817 46.1 36/59 42/52 84/91 63/74 36/37 6.2 6.4 400 2657 1929 840 560 424 105 130 6970 7753 46.4 36/66 45/57 82/91 63/76 36/38 11.1 11.4 400 4733 3436 1405 1005 761 265 230 8730 7737 46.5 36/67 46/58 82/91 63/77 36/39 13.8 14.2 400 5924 4294 1723 1254 961 357 290 8730 8036 44.8 36/69 47/59 81/91 63/78 36/39 14.1 14.5 380 5714 4595 1710 1404 1065 416 350 8730 8127 44.3 36/77 49/65 83/91 63/80 36/41 17.5 17.9 335 5975 5631 2238 1587 1149 662 350 16621 7616 47.3 36/68 45/59 80/85 63/74 36/38 26.2 27.0 400 11016 7403 3237 2101 1528 542 630 16621 8185 44.0 42/83 54/72 79/85 63/78 42/46 32.5 33.5 377 12705 9504 4129 2514 1967 884 670 3758 7817 46.1 36/58 42/52 84/91 63/74 36/37 6.0 6.2 400 2567 1868 817 540 414 97 120 6737 7753 46.4 36/65 45/56 83/91 63/76 36/38 10.7 11.0 400 4572 3322 1369 965 741 247 220 8439 7737 46.5 36/66 45/57 82/91 63/76 36/38 13.4 13.8 400 5722 4147 1680 1214 920 333 280 8439 8036 44.8 36/68 46/58 81/91 63/78 36/39 13.5 13.9 380 5486 4432 1659 1354 1035 384 340 8439 8127 44.3 36/75 48/64 83/91 63/79 36/40 16.7 17.2 335 5718 5404 2168 1517 1108 611 340 17076 7616 47.3 36/68 45/59 80/85 63/74 36/38 26.1 26.6 401 11379 7409 3219 2238 1538 539 640
17076 8186 44.0 42/85 55/73 78/85 63/78 42/46 32.5 33.5 369 12415 9991 4117 2925 2048 901 670
Note: Heat and mass balances are dependent on ambient conditions and plant application, above given figures are for guidance only and calculated at ISO 3046 reference conditions; 25C ambient temperature, 100m above sea level and 30% relative humidity. 1) Heat rate and electrical efficiency at generator terminals, including engine-driven pumps, ISO 3046 conditions and LHV. Tolerance 5%. Power factor 0.8. Gas Methane Number >80
2) Single-circuit cooling system. * Adjustable NOX range according to local requirements. Heat rates given at the marked NOX optimization level. Heat rates at other NOX optimization levels to be checked case by case. Note! 1 ppm-v dry @ 15% O2 2.054 mg/Nm3 dry @ 15% O2, NOX calculated as NO2, Nm3 defined at NTP (273.15 K and 101.3 kPa).
Performance data as guidelines for CHP calculations Wrtsil liquid fuelled generating sets at 50 and 60 Hz
Performance data Engine Engine optimization: NOX (dry @ 15 vol-% O2) Electric power Heat rate 1) Efficiency 1) High temperature circuit inlet/outlet HTCAC temperature inlet/outlet Cylinder temperature inlet/outlet Low temperature circuit inlet/outlet Lubrication oil circuit inlet/outlet LTCAC temperature inlet/outlet Charge air flow Exhaust gas flow Exhaust gas temperature Exhaust gas heat High temperature circuit-energy HTCAC energy Cylinder cooling energy Low temperature circuit-energy Lubrication oil energy LTCAC energy Heat losses by radiation 5% 5% 15 ppmvol kW kJ/kWh % C C C C C C kg/s kg/s C 84/91 34/47 63/78 34/44 3.5 3.6 303 1052 371 371 832 246 586 68 Wrtsil diesel engines at frequency 50 Hz 9L20 12V32 16V32 18V32 20V32 18V46 Wrtsil diesel engines at frequency 60 Hz 9L20 12V32 16V32 18V32 20V32 18V46
710*-780
710*-970
710*-970
710*-970
710*-970
900*-970
710*-780
710*-970
710*-970
710*-970
710*-970
900*-970
5327 7880 45.7 79/96 87/96 79/87 38/49 63/77 38/43 10.2 10.5 347 3629 1891 1044 847 1246 657 589 185
7124 7856 45.8 80/96 87/96 80/87 38/49 63/78 38/43 13.6 14.0 348 4849 2453 1319 1134 1668 877 791 247
8032 7840 45.9 80/96 88/96 80/88 38/49 63/78 38/43 15.3 15.7 349 5472 2726 1443 1283 1885 988 897 278
8924 7840 45.9 80/96 87/96 80/87 38/49 63/79 38/43 17.0 17.5 349 6082 3030 1604 1426 2093 1097 996 308
17076 7698 46.8 80/91 83/91 80/83 42/55 63/80 42/47 31.6 32.5 346 11212 5135 3484 1651 3750 2249 1501 451
1454 8561 42.0 84/91 84/91 34/48 63/77 34/44 3.3 3.4 302 991 345 345 776 221 556 68
5211 7880 45.7 80/96 87/96 80/87 38/49 63/77 38/43 9.7 10.0 352 3515 1805 971 834 1205 646 559 180
6970 7856 45.8 80/96 87/96 80/87 38/49 63/78 38/43 13.0 13.3 352 4698 2427 1309 1118 1623 862 761 240
7841 7861 45.8 80/96 88/96 80/88 38/49 63/78 38/43 14.6 15.0 354 5306 2654 1388 1266 1829 972 857 270
8730 7840 45.9 80/96 88/96 80/88 38/49 63/79 38/43 16.2 16.7 354 5897 2949 1543 1407 2032 1080 951 300
17076 7698 46.8 80/91 83/91 80/83 42/55 63/80 42/47 31.6 32.7 344 11222 5141 3490 1651 3753 2249 1504 451
Note: Heat and mass balances are dependent on ambient conditions and plant application, above given figures are for guidance only and calculated at ISO 3046 reference conditions; 25C ambient temperature, 100m above sea level and 30% relative humidity. 1) Electrical output at generator terminals, including engine-driven pumps at 100% load. ISO conditions and LHV (42700 kJ/kg). Tolerance 5 %. Power factor 0.8.
* Adjustable NOX range according to local requirements. Heat rates given at the marked NOX optimization level. Heat rates at other NOX optimization levels to be checked case by case. Note! 1 ppm-v dry @ 15% O2 2.054 mg/Nm3 dry @ 15% O2, NOX calculated as NO2, Nm3 defined at NTP (273.15 K and 101.3 kPa).
15
Wrtsil is a global leader in complete lifecycle power solutions for the marine and energy markets. By emphasising technological innovation and total efficiency, Wrtsil maximises the environmental and economic performance of the vessels and power plants of its customers. In 2008, Wrtsils net sales totalled EUR 4.6 billion with 19,000 employees. The company has operations in 160 locations in 70 countries around the world. Wrtsil is listed on the NASDAQ OMX Helsinki, Finland.