Sei sulla pagina 1di 4

Srinivasan.

P
Plot No: 64
Busy street, Krishna nagar west,
Dobbi canal near.
Lawspet.
Pondicherry - 605008


______________________________________________________________________

OBJECTIVE

To have career in Tech. Services and to obtain responsible position using my
experience of over 17 years in Electrical field and Projects maintenance
______________________________________________________________________

MobiIe : 8754906050 and 9159186749

E- MaiI : pavasrini@yahoo.in

Date of Birth : 12 February1972


EducationaI QuaIification:

IndustriaI Training Institute (ITI) in electrical from Government .T. cuddalore during
1990-1992 with an overall aggregate of 90.4%.

DipIoma in electrical and electronics engineering from padalesuwarar polytechnic
college, cuddalore, government of Tamil nadu during 1993-1995 with an overall
aggregate of 73.70%


IndustriaI Experience:
Joined as Trainee and presently working as Senior Executive in
M/s. Shasun Pharmaceuticals Limited., Periyakalapet, Pondicherry from June 1998 to
till date in Electrical Department.
Other company experience:
1. Parry Confectionary Limited from November'1995 to June'1996.
Chemfab Chlorates Limited from January'1997 to August'1997



ResponsibiIities:

O Responsible for maintenance of all electrical equipments.
O Planning and implementation of preventive maintenance and breakdown of
electrical equipments.
O Preparation of preventive maintenance schedule for electrical equipments.
O Planning materials required for maintenance and procurement for stores.
O Liaison with state electricity officials.
O Planning and execution of all new electrical equipments.
O Generation of work orders and indents.
O Preparation of daily reports.
O Man power planning.
O nformation near miss incidents to safety department and reporting head.
O Monitor the subordinates/shop floor people for usage of proper PPEs while at
work.
O Responsible for giving feedback on compliance of PPEs to safety department
and reporting head.
O Follow up and implementation of safe practices displayed in appropriate areas.
O Responsible to update the asset register.
O Reporting the security incidents or security risks to the organization.
O Responsible for maintain the information related to the department according to
the policies.
O Responsible for the protection of the asset from unauthorized disclosure, access,
modification or destruction.
O Call of service person to carry out AMC for critical electrical equipment within the
frequency.
O Conducting Electrical safety classes for the employees.
O Responsible for calibrating the electrical instruments and earth pit according to
frequency.
O Responsible to follow the technicians where using LOTO system for electrical
works.
O Responsible for making comparative among various external parties.

reas of speciaIization:

Electrical Motors, HT-Yard (2-pole structure),
Boiler,Transformer, Diesel Generator, Starters (DOL, Star Delta, soft starter), Variable
speed control drives (Eurotherm), Motor control center panels, PLC, DCS, Electrical
power saving and Electrical Safety.




Strengths:

Plant Electrical faults Trouble Shooting identifying and rectification,
Problem Solving,



To Operate and maintained:

O HT yard -22kv,2pole structure substation
O Motor control centre panels, 440volt, 50HZ
O Boiler and other utility electrical controls.
O 250KVA-1no, 800KVA-1no, 1000KVA-2nos Diesel Generators during power
failure.
O Vacuum Circuit Breakers and Air Circuit Breakers
O Transformer(5000Kva) and Capacitor banks 1600kvar
O DG Maintenance and servicing based on running hours
O DOL and Star delta starter control circuit & Power circuit faults analysis and
rectifying the fault
O Soft starter and Drives maintenance.
O Pre scheduling the shutdown work, man power and pre maintaining the
materials and spares required for shut down work
O Maintenance of lighting arrestor as per frequency
O New earth pit erection and maintenance work
O Air curtain nstallation and maintenance work
O Transformer oil filtration maintenance work.
O UPS controls and emergency power controls.
O AHU maintenance of all plants.



chievements:

Power saving done

O Provided speed control drives for the centrifuges and reactor motors (speed
controlled based on production).
O Provided E1 energy efficiency 50hp motors instead of E2 efficiency motors.
O Provided Del star convertor for reactor motors.
O Provided temperature sensor in order to control continuous running of cooling
tower high kW fan motor.



Project works done:

O Expansion of Pilot plant, Biotech plant,bu derivative plant,Pharma plant.
O New erection of chilling plant motors and boiler.
O New plant AHU erection works




hereby certify that the above information is true to the best of my knowledge.