Sei sulla pagina 1di 4

CURRICULUM VITAE Name:E.Karthick.

Testing & Commissioning Engineer Nature of work experience TESTING AND COMMISSIONING: JOB PROFILE Testing & Commissioning of Static and Numerical Protection Relays of various types of leading makes. Maintenance testing of relays, Breaker and calibration of Digital Meters, Energy Meter. Testing and commissioning of 415V to 400KV Indoor / Outdoor substation and substation equipments. Testing of individual equipments such as CTs, PTs, CVTs, Breakers (SF6/Vaccum), Isolators and Protection relays in 400 kv,220 kv,132kv,33kv and 11kv Outdoor Substations. Testing of CTs, PTs, Breakers (SF6,Vaccum,Oil,Air) and protection relays in 33/22/11/6.6/0.415 KV Switchgears located in various industries (steel,sugar,petroleum,cement) and power plants (Diesel, Thermal). Trouble shooting of various electrical systems at different type of process Plants and power plants. Testing of Control and relay panels of various substations (400 kv,220 kv,132kv,33kv and 11kv) And their overall scheme checking. Testing of Power Transformers up to 315 MVA with OLTC schemes, protection schemes-, various protection tripping, interlocks, intertripping. Scheme checking for HT Switchgears viz. 6.6KV, 11KV and 33 KV panels. Scheme checking for different Switchyards viz. 400 kv,220 kv,132kv,33kv and 11kv High Voltage testing for Cables and Bus bar Preparation of pre-commissioning check lists, test reports, as built drawings, cable schedules and detailed commissioning schedules for the above mentioned systems. Preparation of detailed work schedule, drawings, cable schedules to carry out the shutdown work for modifying or upgrading the existing electrical systems such as additional bays in existing substations, additional panels to existing switchgears. Testing of various types of relays of Areva likely-, Transformer protection, LBB protection, Motor protection, Switchgear feeder protection, O/C&E/F Protection and Over/Under Voltage protection Testing and commissioning of Protection Schemes Testing and commissioning Generator protection system.

Page 1 of 4

Testing and commissioning Motor protection system. Testing and commissioning Feeder protection system. Testing and commissioning Bus bar protection system. Testing and commissioning line distance protection system Major projects executed in India Project: : DVC Thermalpower plant in Chandrapura Client : BHEL Job Responsibility : scheme and panel function checking Description :Unit-8(315MVA,16.5KV) commissioning activities such as Back charging, Stability,Generator OCC,SCC test and Synchronization coordination with BHEL.Configuration and Testing of Siemens relays 7UM62,7UT61,7UT61,7SJ62. Project : TATA Thermal power plant in TATA Nagar. Client :TATA Thermal power plant Job Responsibility : scheme and panel function checking Description :Unit-5(150MVA,11KV) activities such as Back charging, Stability,Generator OCC,SCC test and Synchronization coordination with BHEL.Configuration and Testing of Siemens relays 7UM62,7UT61,7UT621,7SJ62. Project :DVC 220/132KVswichyard in Koderma Client :TECHNO Job Reponsibility : scheme,CB interlocks, panel function checking,Testing Backup relays (Direction Over current, Earth fault), Auto Recloser function in 7SA612.calibration of the meter. Description :Configuration and Testing of Siemens relay7SA612,7SA621,7SJ622,7UT62. Unit-2(220/132KV)commissioning coordination with TECHNO. Project :Commissioning of 400MW motor protection in Uthdharapur. Client :Greenpl Industry Pvt. Ltd. Job Reponsibility :testing of equipments CT,PT,VCB scheme.Configuration and Testing of Siemens relays 7UM62, Backup over current and earth fault relays. Project :108MW Gas power plant in Delhi. Client :North Delhi Power Corperation Job Responsibility:Retorfitting panel work and prepare the cable schedule as per scheme.configuration and testing of Siemens relay 7UM62,7SJ62. primary injection and stability test. Project :132/11KV Switchyard for Ganesh metalicks(p)ltd in Rourkela. Client :EM power pvt.ltd. Job Responsibility:Equipment testing of current transmer,capacitor voltage transformer , surge arrester and earth value.SF6 Breaker operation and Isolator operation.primary injection for CT. Project :400KV Switchyard for APGENCO in Palvacha. Client :BGR Pvt. Ltd. Description : Commissioning and testing of 400 KV Thermal power Substations consisting of 8 Bays with one and half scheme. Configuration & testing of Siemens Relays distance protection 7SA52,7SA61,directional over current 7SJ80,LBB7SV60,busbar protection 7SG143Duobias,auxiliary relay. Job Responsibility:scheme ,panel function checking for distance,differential,bus bar protection and interlocks,auto recloser scheme.MLFB number change for distance protection due to parallel compensation. Checking Digital measuring meters and Energy meter. Auto reclosure Scheme check. Primary injection and stability for busbar and transmission line,Back charging for ST and GT.checking and calibration of digital meters.

Page 2 of 4

Commissioning activities such as Stability,Generator OCC,SCC test and Synchronization coordination with BGR andAPGENCO. Project :220/110KV Switchyard in Neral-Maharastra Client :MSEB Job Reponsibility :. Scheme checking , panel function checking for distance, differential, bus bar protection.SF6 CB and Isolator operation. Configuration and testing of Areva Distance protection P441,Differential P632 Backup Overcurrent P127 relays. checking and calibration of digital meters Experience with ALSTOM / AREVA RELAY Directional/Non-directional O/C Relay : - P122, P127 Transformer Differential Relay : - P632, P633 Distance Protection Relay : - P441,P442 Experience with SIEMENS RELAY Directional/Non-directional O/C Rela Generator Protectiopn relay Transformer Differential Relay Distance Protection Relay Bus Bar Protection Breaker Failure Relay Bay Control Unit Auto Reclose . Testing Kits Used:

: -7SJ621 :-7UM62 : -7UT612,7UT613,7SG143(DUOBIAS) : -7SA621,7SA622 :-7SS60 : - 7SV600 :- 7SJ622 :-7VK611

Omicron CMC 256, Omicron356 Doble(FS600) Contact Resistance Meter Scope 100Amps single Pole Timer Scope l High Pot Kit 40Kv Loading Transformer 2000Amps Digtal megger(BM11D/MERTEL) Secondary Injection Kit

Career Profile 1. Organization : M/s Powersystem Desining and commissioning System. Designation : Testing & Commissioning Engineer Period : June 2009 to June 2011. Job location :Site Anywhere in India.

Professional Details Professional Qualification Electronic Engineering. Institute : B.E.(ELECTRICAL AND ELECTRONICS) Electrical & : Sethu Institute of Technology.

Page 3 of 4

Year of completion

: 2009 April

PERSONAL DETAILS Fathers Name Date of Birth Nationality Sex Marital Status Languages Known :A.Esakki : 12.06.1987 : Indian : Male :Singel :English,Tamil

Passport Details: Passport No. : H 6729369 Valid up to : 02/09/2019 Issued at :Madurai

DECLERATION I E.Karthick hereby declare that the above given details are true to the best of my knowledge and belief. Date: Signature

Page 4 of 4