THE PROCESS
The activated sludge process relies on a dense microbial population being in mixed suspension with the wastewater under aerobic conditions. With unlimited food and oxygen, extremely high rates of microbial growth and respiration can be achieved resulting in the utilization of the organic matter present to either oxidized end products (i.e. CO2, NO3, SO4 and PO4) or the biosynthesis of new micro-organisms (Section 15.1). The activated sludge process relies onfiveinter-related components: the reactor, the activated sludge itself, the aeration/mixing system, the sedimentation tank and the returned sludge (Table 17.1 and Fig. 17.1). However, there is an increasing interest in replacing the sedimentation tank unit with either an internal or
TABLE 17.1
Main components of all activated sludge systems 1. The reactor: This can be a tank, lagoon or ditch. The main criteria of a reactor are that the contents can be adequately mixed and aerated. The reactor is also known as the aeration tank or basin 2. Activated sludge: This is the microbial biomass within the reactor which is comprised mainly of bacteria and other microfauna and flora. The sludge is a flocculant suspension of these organisms and is often referred to as the mixed liquor. The normal concentration of mixed liquor expressed as suspended solids (MLSS) is between 2000 and 5000 mgl"^ 3. Aeration/mixing system: Aeration and mixing of the activated sludge and incoming wastewater are essential. While these tasks can be performed independently they are normally carried out using a single system, either surface aeration or diffused air is used 4. Sedimentation tank: Final settlement (or clarification) of the activated sludge displaced from the aeration tank by the iucoming wastewater is required. This separates the microbial biomass from the treated effluent 5. Returned sludge: The settled activated sludge in the sedimentation tank is recycled back to the reactor to maintain the microbial population at a required concentration in order to ensure continuation of treatment
444
445
Aeration tank
Sedimentation tank
^ /\
- - ^
^0' ^0' ^0
Influent i i
x,v,s
Oo+OpXS
Mixed liquor
^0
^ W ''
Effluent ^
Qu' ^U
FIGURE 17.1 Schematic diagram of the activated sludge process where A is the surface area of the sedimentation tank, Fis the aeration tank volume, S is the substrate (food) concentration, Q^ is the influent flow rate, Qj. is the returned activated sludge (RAS) flow rate, Q^ is the waste activated sludge (WAS) flow rate, X is the aeration tank MLSS concentration, X^ is the RAS suspended solids concentration, X^ is the effluent suspended solids concentration and X^ is the WAS suspended solids concentration, which is normally equal to Z^.
external membrane filtration unit to separate the solids from the final effluent (Section 20.8.5). Removal of organic matter (substrate) in the activated sludge process comprises of three mechanisms: (a) adsorption and also agglomeration onto microbial floes, (b) assimilation which is the conversion to new microbial cell material, (c) mineralization which is complete oxidation. The predominant removal mechanism can be chosen by specific operating conditions. For example, conditions favouring assimilation removes substrate by precipitating it in the form of biomass, which results in a higher proportion of the cost required for sludge separation and disposal (high-rate activated sludge). Under conditions favouring mineralization the volume of biomass is reduced under endogenous respiratory conditions. This results in lower sludge handling costs but higher aeration costs. Currently the higher cost of sludge treatment and disposal favours plants operating with low sludge production. The relationship between substrate (food) concentration and sludge biomass (micro-organisms) concentration is a fundamental one in activated sludge operation (Fig. 17.2). In the activated sludge plant the mass of micro-organisms multiply rapidly in presence of oxygen, food and nutrients. After maturation, the micro-organisms are developed to assimilate specific waste (log growth phase), which is the period of maximum removal. Then under substrate-limiting conditions, the micro-organisms enter a declining growth phase leading eventually to auto-oxidation (or endogenous respiration). In practice activated sludge processes operate towards the end of the log phase and in the declining/stationary growth phases (Section 15.2.1).
446
Logarithmic dispersed
Declining
Stationary flocculant
Endogenous
Extended
Aerobic digestion
y ^
n 3
FIGURE 17.2
D)
IS C O
\J
/ / / / / / / \ \ \ \ \ \ s
**" ^
Time Substrate ^s,^^ Sludge
The microbial growth curve showing the operational growth phase used in different modes of activated sludge. (Reproduced from Winkler (1981) with permission of Ellis Horwood Ltd, Chichester.)
c .9 2
0)
o c O
17.2
PROCESS CONTROL
A number of parameters are used to operate activated sludge plants. Those most important in process control can be categorized as: (a) (b) (c) (d) biomass control, plant loading, sludge settleability, sludge activity.
447
Comparison of loading and operational parameters for different activated sludge treatment rates Retention period (h) BOD loading per capacity (kg BOD m-^d-^) Sludge loading (f/m) (kg BOD kg-^ d-^) Sludge Sludge age (d) production kg dry sludge per kg BOD removed 3-4 0.5-.08 Application
Conventional 5-14
0.4-1.2
0.2-0.5
Conventional treatment for medium and large works to produce 20-30 effluent with or without nitrification depending on loading within range For pre-treatment or partial treatment Extended aeration for full treatment on small works. Effluent highly stabilized but may contain fine solids
High Low
1-2 24-72
>2.5 <0.3
>1 <0.1
Reproduced from Hawkes (1983) with permission of Academic Press Ltd, London.
Other methods must be used if an accurate estimation of microbial activity is required (e.g. biochemical assessment), although for routine operational control the MLSS is sufficient. The normal MLSS range is 1500-3500 mgl"^ for conventional activated sludge units, rising to 8000mgl"^ for high-rate systems (Table 17.2). The MLSS concentration is controlled by altering the sludge wastage rate. In theory the higher the MLSS concentration in the aeration tank, then the greater the efficiency of the process as there is a greater biomass to utilize the available substrate. However, in practice, high operating values of MLSS are limited by the availability of oxygen in the aeration tank and the ability of the sedimentation unit to separate and recycle activated sludge. Sludge residence time or sludge age The sludge residence time (SRT) is the time in days that the microbial sludge spends in the activated sludge process (Equation (17.1), both within the aeration tank and while being separated or returned. The SRT {t^ is calculated by using Equation (17.2): SRT Total amount of sludge solids in the system Rate of loss of sludge soHds from system
^s =
(17.1)
VX {Q^X^) +
(17.2) {Q,X,)
where V is the volume of liquid in the aeration tank (m^), X^ is the MLSS in waste stream ( m g r ^ ) , X i s the MLSS (mgl"^), Q^ is the effluent discharge rate (m^ day"^).
448
Chapter 17 / Activated Sludge Qw is the sludge wastage rate (m^ day~^) andXg is the suspended soUds concentration in the effluent (mg 1"^). If the proportion of microbial cells in the MLSS is assumed constant, then the SRT can be referred to as either sludge age or the mean cell residence time (MCRT). In practice, if the amount of sludge in the aeration tank is constant (VX) then the sludge wastage rate (Q^X^) is the net sludge production of the system in kg DS day~i. SRT is the operational factor giving control over sludge activity and is controlled by altering the sludge wastage rate. A low SRT (<0.5 days) produces a sludge with a high growth rate as used in high-rate units for pre-treatment or partial treatment, which produces a high volume of waste sludge. A high SRT (>0.5 days) produces a low growth rate sludge, as in extended aeration systems, which produces a low volume of sludge which is more stabilized. Conventional activated sludge has an SRT of 3-4 days, which gives good settling properties. Long sludge ages in excess of 6 days result in poor settling properties.
where Fis the total liquid capacity of the aeration tank (m^) and Q is the rate of flow of influent wastewater to the tank (m^ day~^). Expressed in hours, HRT does not take into account theflowof recycled activated sludge to the aeration tank, which can be 25-50% of the overallflow.Therefore, the actual HRT is much less than calculated by Equation (17.3). For that reason it is known as the nominal retention time. The HRT must be long enough to allow the required degree of adsorption, flocculation and mineralization to occur. In conventional plants the HRT is 5 h at dry weather flow (DWF). During a storm when the loading increases to 3 DWF with maximum recycle of sludge (1.5 DWF), the actual HRT may be as short as 1 h. The recycle ratio (r) is the returned activated sludge flow rate {Q^) divided by the influent flow rate {Q): r =^ Q (17.4)
Typical ratios are 0.25-0.5 for conventional systems, and between 0.75 and 1.5 for extended aeration.
449
Organic loading is the biochemical oxygen demand (BOD) load in relation to the tank capacity. As the organic content of wastewaters vary then loading (OL) should be expressed as kg BOD per unit aeration tank volume: OL = G i i B O D V X 1000 gQj^ ^_3 1 (^7 5)
For conventional units this is 0.4-1.2kg BOD m~^day~\ while for high rate >2.5, and for extended aeration <0.3kg BOD m"^day~^ As the biomass is actively removing the organic substrate in the wastewater, it follows that the BOD loading should be related to the volume of biomass in the aeration tank (i.e. sludge loading). The sludge loading is normally referred to as the food (f) to micro-organism (m) ratio: X ^ Organic loading rate ^ 6 X BOD ^^ ^^^^^ m Volume of biomass VX ^^ ^^^^^^ ^^^_, ^^^ ^^
When the f/m ratio is high the micro-organisms are in the log growth phase with excess food, maximum rate of metaboHsm and large removal of BOD. However, under these conditions, the micro-organisms do not form floes but are dispersed making it difficult to settle and recycle the biomass (sludge). Because food is in excess, not all the substrate is used and so will be lost in the final effluent resulting in a high BOD (e.g. high-rate systems). In contrast, with low f/m ratios the micro-organisms are in a food-limited environment, even though the rate of metabolism may be high when the recycled micro-organisms are first mixed with the incoming wastewater. Once food is limiting, the rate of metabolism rapidly declines until the micro-organisms are in the endogenous respiration phase with cell lysis and resynthesis taking place. Therefore, almost complete oxidation of substrate occurs producing a high-quality effluent, low BOD, good flocculation and sludge settlement. Overall, the lower the f/m ratio, the lower the rate of metabolism and the greater the BOD removal and sludge settleability (Fig. 17.3). However, as removal efficiency increases so does the overall oxygen demand of the system and so the overall cost of BOD removal. Floe load is used to measure the organic loading over a specified period of time at the point where the influent wastewater to the aeration tank mixes with the returned biomass. It can be expressed in terms of BOD or chemical oxygen demand (COD) (mgl"^) in relation to the MLSS (gl"^) concentration: _, , , COD per unit of time at point of mixing ^ _ .^ . ^^r c^c Floe load = ^ i2_ mg CODg'^ MLSS MLSS per unit of time at point of mixing (17.7)
450
O ^
o E
90
80
a.
FIGURE 17.3
(17.8)
A good sludge should have an SVI <80 ml g"^ and a very good one around 50 ml g"^. An SVI > 120mlg~^ indicates poor settling properties. The SVI test is severely affected by high MLSS concentrations with virtually no settlement occurring at concentrations > 4 0 0 0 m g r ^ Also, due to the quiescent conditions in the SVI test, sedimentation proceeds past the hindered settlement stage in which all the sludge floes are evenly distributed (type III settlement); transitional or even compression settlement phases may have started (type IV) making the test less representative of actual sedimentation tank conditions (Gray, 2004). These problems are overcome by using the SSVI, which is now widely used, especially where a more accurate assessment of sludge settlement is required. It is measured using a special settling column 0.5 m deep and 0.1m in diameter, with settlement impeded by a wire stirrer rotating at Irevmin"^ (Fig. 17.4). This test reproduces the non-ideal situation found in sedimentation tanks where the SVI is measured under complete quiescence (White, 1975). The SSVI is calculated by pouring approximately 3.51 of homogeneous mixed liquor
451
FIGURE 17.4
The standard SSVI settling apparatus developed at the Water Research Centre and available from Triton Ltd, Great Dunmow, Essex.
into the cylinder to the 50 cm level. The stirrer is connected and the height of the sludge interface in the column measured QIQ). After 30min the height of the sludge interface is measured again (hi) and the SSVI calculated as: SSVI 100 h ^mlg-i Qho (17.9)
where Q is the initial concentration of suspended solids (per cent w/w) (i.e (MLSS (gr^yiOOO) x lOO) ( D O E , 1985). In terms of SSVI a good sludge has a value <120mlg~\ while a sludge with poor settleability has a value >200mlg~^
452 Chapter 17 / Activated Sludge a spectrophotometer (Section 15.3.4). The response of dehydrogenase to changes in the activated sludge is both rapid and sensitive. However, none of these methods are simple to carry out and are generally expensive (Coackley and O'Neill, 1975). The simplest and most direct measurement of sludge activity is the specific oxygen consumption or uptake rate (SOUR). It can be measured in either in the field or the laboratory byfillinga BOD bottle with mixed liquor and using an oxygen electrode fitted in the bottle to measure the fall in oxygen concentration over time: SOUR = Oxygen depletion (mg 1-1 min-^) ^ ^^ MLVSS(g) ^_, ^^^ ^Q)
17.3
MODES OF OPERATION
By using different combinations of the main operating parameters, various different rates and degree of treatment are possible. Thisflexibilityin design, allowing operation over a wide range of loadings to suit specific treatment objectives, is the major advantage of the activated sludge process over other treatment systems. While primarily designed to remove carbonaceous BOD, with suitable operational control and plant modifications it can also achieve nitrification, denitrification and phosphorus control (Section 18.4). Depending on sludge loading then activated sludge plants can be categorized as high-rate, conventional or extended aeration, although the delineation between these categories is by no means precise and these terms are used in their broadest sense.
17.3A AERATION
This is a major operational variable. The main functions of aeration are: (a) to ensure an adequate and continuous supply of dissolved oxygen (DO) for biomass; (b) to keep the biomass in suspension; (c) to mix the incoming wastewater with the biomass, and to remove from solution excess carbon dioxide resulting from oxidation of organic matter. Two aeration systems are generally employed, although there are other method available (e.g. sparges). Surface aeration is where aeration and mixing is achieved b the use of blades or vanes that are rotated at speed. The aerator rotates either abo] a vertical or horizontal shaft (Fig. 17.5) and is positioned at or near the surface of tl Hquid. The action of the blades causes considerable turbulence resulting in enhanc oxygen transfer. Diffused aerators supply oxygen, which is supplied directly to t aeration tank via a series of diffuser domes (Fig. 17.6). The air is pumped under pr sure that causes considerable turbulence and hence mixing. The size of the pore the diffuser controls both the size and the number of the air bubbles and so the i ^f oxveen transfer (Gray, 2004).
453
Terminal box 2
FIGURE
17.5
General arrangement of a Mammoth horizontal rotor. (Reproduced with permission of Gerald O'Leary, Environmental Protection Agency, Wexford.)
Dome diffuser. (Reproduced from IWPC (1987) with permission of the Chartered Institution of Water and Environmental Management, London.)
454
Chapter 17 / Activated Sludge The oxygen demand of the mixed Uquor varies during the day, so it is vital that oxygen (or redox) control is used within the aeration tank. In this way the oxygen supplied can be matched to the demand preventing overaeration. Where the plant is operated at design loading, the inclusion of oxygen control can reduce the overall power consumption by as much as 40% (Fig. 17.8). An undesirable design feature is the use of a single vertical aerator in a deep tank, resulting in the aerator never being able to be turned off due to the problem of re-suspending the mixed liquor once it has settled. The separation of the mixing and aeration functions by using a paddle system and diffusers, respectively, is the preferred design for most plants allowing the costly aeration to be switched off while still maintaining the mixed liquor in suspension, unless several mechanical aerators can be included within the aeration tank.
200
Power drawn
O
O)
FIGURE 17.7
Q.
CO O
100
The OC and power used by a cone aerator at various depths of immersion. (Reproduced from Rachwal and Waller (1982) with permission of C.E.R Consultants, Edinburgh.)
CO
CD
50
I 100
,
300
400
FIGURE 17.8
The effect on power consumption by aerators in an oxidation ditch when DO control is used. (Reproduced from Cox et al. (1982) with permission of C.E.R Consultants, Edinburgh.)
o a.
455
KL^{T)
log,
(Q - Q)
(17.11)
where C^ is the saturated DO concentration (mgl"^), Ci and C2 are the DO concentrations (mgT^) at times ti and^2 (min), respectively. The mean (Kia) value is taken as the (Ki3.) for the whole system. The OC of the aeration system is calculated using the following equation: OC = K^a(T) XV X Q(T) X 10-3 kg h-i (17.12)
FIGURE 17.9
The relationship between the saturated DO concentration (C3), the DO concentration at time zero (CQ), the concentration at time t (CL) and the DO deficit ( Q - CL).
Time
456
Chapter 17 / Activated Sludge where V is the volume of water used in the test, T is the temperature of the water and C^(T) is the oxygen saturation concentration of clean water at test temperature T. The transfer rate coefficient (Ki^^) is dependent on temperature and is expressed at a standard temperature of 20C (i.e. {Ki^3)2o)' Therefore, it must be converted using: = (iCLa)2o(1.024f-20 (17.13)
{K^^)T
where T is the temperature at which (i^La) is measured (Section 6.3). The values for (^L^) obtained using clean water by this method will be higher than those obtained using activated sludge. The impurities in wastewater have significant effects on Xj^a. For example, both fatty and surface active materials such as detergents reduce the rate of oxygen transfer. However, detergents and fatty acids when present as soaps (pH > 6) are able to increase Kj^a by preventing bubble coalescence, thus maintaining the mean bubble size at a lower level than if such chemicals were absent. This increases the total interfacial area thus increasing the overall mass transfer of oxygen. These two opposing effects rarely cancel each other out and so must be considered in the calculation of Ki^s.. Other impurities in water can also alter KI^L; therefore the effects of all impurities must be calculated together by measuring the a factor (IWPC, 1987): a factor = (^La) wastewater (iCj^a) clean water (17 14)
The value of i^La varies for each type of wastewater and also the duration of aeration. For example, a varies from 0.3 at the beginning of the aeration period for domestic sewage to 0.8 after 4 h aeration. Typical a values for mixed liquor vary from 0.46 to 0.62. The impurities in wastewaters will also affect the oxygen saturation concentration compared with clean water at the same temperature. This is adjusted by the j8 factor where: ^ factor = Q i " ^ ^ ^ t e w a t e r Q in clean water (17.15)
The j8 value normally approximates to 0.9. Once the a and j8 factors are known for a particular wastewater, then the clean water test results can be used to predict the expected field results. Details of testing aerators, including a worked example, are given in IWPC (1987). Aeration efficiency in terms of mass of oxygen transferred to the mixed liquor per unit of energy expended is expressed as kg O2 kWh~^ An estimate of aeration efficiency can be made by measuring the oxygen demand (OD) exerted by carbonaceous
457
oxidation and nitrification, taking into account the flow rate, influent and effluent BOD concentrations using the following equation: OD = 0.0864(7,[0.75(BODi - BODe)] ^ 5.25 X 10-4 X CMLSS X V + 4 3(^. _ N,)kgday-' (17.16)
where q^ is the meanflowrate of settled influent (1 s~^), BOD is the mean BOD of the influent (i) and effluent (e) (mgl"^), CMLSS is the mean MLSS concentration (mgl~^), Fis the aeration tank volume (m^), and N is the mean ammonia concentration in the influent (i) and effluent (e) (mgT^). The calculated oxygen demand can be converted to aeration efficiency by dividing by the daily power consumption (kWhday"^). While this assessment is not as accurate as standard performance tests, it does allow an excellent comparison between plants without the prohibitive expense oiin situ tests (Chambers and Jones, 1988).
17.4
458
FIGURE
17.10
Comparison of the utilization of substrate and oxygen, and the production of oxidation products through a plug flow and completely mixed reactor.
Oxidation products
c o
Substrate 1 Oxygen
2
c
CD O
c o O Length Length
Substrate
elongated rectangular aeration tank. Typical dimensions are 6-10 m wide, 30-100 m long, 4-5 m deep. As biomass proceeds down the length of the tank: (a) treatment occurs, the degree depending on retention time; (b) the microbial growth curve is discernible as in batch systems with sludge activity high at the inlet, but low at the outlet; (c) there is rapid removal initially but becoming progressively slower; (d) a discernible BOD gradient is formed. Disadvantages of plug-flow systems include: (a) DO deficiency occurring at the inlet where oxygen demand is greatest; (b) oxygen is usually in excess at the outlet where oxygen demand is least; (c) as toxic and shock loads are not diluted or buffered, they pass through the tank as a discrete plug, often resulting in serious effects on performance. Advantages include: (a) no short circuiting within the aeration tank, although baffles can increase the HRT even more; (b) plug-flow systems produce sludges with good settleability. In completely mixed systems, the influent wastewater and returned sludge are immediately mixed and instantly diluted giving a uniform loading throughout the aeration tank. Advantages include: (a) minimizing the effects of toxic and shock loads; (b) plug-flow MLSS concentrations are between 2000 and 3000 m g r \ while completely mixed MLSS concentrations are much higher at 3000-6000 mgl"^ permitting higher BOD loadings.
459
Influent
Sludge return
FIGURE 17.11
The oxidation ditch with a single rotor is close to the idealized design of a plug-flow reactor generally used in the treatment of wastewater.
Influent
' Effluent
Sludge return
Disadvantages include: (a) possible short circuiting in the aeration tank; (b) a low density sludge is produced; (c) poor settleability; (d) no nitrification possible. These disadvantages can be overcome by using aeration tanks in series, which is approaching plugflowin design (Fig. 17.11). 17.4.2 COMPLETELY MIXED REACTORS Using Fig. 17.1, mass balance equations for biomass production (Equation (17.17)) and substrate (food) utilization (Equation (17.20)) in activated sludge can be developed (Benefield and Randall, 1980):
eo^( 0^0
Influent biomass
y ~ Biomass production
(17.17)
Using the Monod function (Equation (15.17)) for the specific growth rate of biomass, Equation (17.17) can be rewritten as: Go^o + V
n^sx
K,+S
(17.18)
460 Chapter 17 / Activated Sludge If the biomass in the influent and effluent are neghgible (i.e. X(j=Xe = 0), then:
Mrn*^ _ Q w ^ w ^ 1^
(17.19)
K,+S
VX
At
Substrate consumed
(17.20)
Using the equation for substrate utilization from Section 15.2: d5 _ 1 y-xa^X dit Y K,+S (17.21)
QoSo - V
1 ii^SX Y K,+ S
(17.22)
The substrate in the aeration basin is equal to that in the secondary settlement tank and in the effluent (i.e. 5 = 5,, = 5e), so Equation (17.22) can be rearranged as: f^mS K.+S _
QQY
VX
(So - S)
(17.23)
0w^ +K =^I(5
VX VX
5)
(17.24)
(17.25)
The MCRT in the aeration basin {<l>c) is derived from Equation (17.2) as:
{<Pc) =
VX
(17.26)
461
As a fraction of the biomass from the sedimentation tank is returned to the aeration basin < c > <AJ Equation (17.24) becomes: ^ 1 1 y + ka = - ( 5 o - 5 ) 4 </> ^ So the MLSS in the aeration basin (X) can be calculated as: X = -^y (17.28) (17.27)
4>
[l + Mcj
The f/m ratio is determined from Equation (17.6) using the notation in Fig. 17.1 as: (17.29)
m 4>X
(17.30)
17.1 Calculate the aeration basin volume (F), the HRT (</>), the volume of sludge wasted each day (Gw)? the mass of sludge wasted each day (Q^^, the fraction of sludge recycled Gr/Go ^iid the f/m ratio for a completely mixed activated sludge system. Population equivalent served is 60000 with a per capita water use of 2251day~^ influent BOD (5o) is 280mgl~^ required effluent BOD is 20mgl~^ yield coefficient (y) is 0.6, decay rate (k^ is 0.06 day~^ Assumed optimum operational factors are aeration tank MLSS {X) 3500mgr\ WAS MLSS {X^) MOOOmgr^ and a MCRT (</)) of lOday"^ Express values in m^, kg and day~^ (a) Calculate the aeration tank volume (V): By combining Equations (17.25) and (17.28):
ia^
<i>.Q^Y\'
(17.31)
s^-s\
(17.32)
X
V =
. l + ^d<A:J
462
Chapter 17 / Activated Sludge (b) The HRT is calculated using Equation (17.25):
^ J Z ^ L = 0.279 day-i
13 500 (c) Volume of wasted sludge per day (Qw)* Using Equation (17.26) then:
Gw = - ^ 3761X3.5 = 10 X 14 (d) Mass of sludge wasted each day = 140 {Q^^)\ 13 164 ^, ^ , ^ . = 94.0 m^ day"i
(17.33)
Gw^w = 94.0 X 14 = 1316 kg day-i (e) Fraction of sludge recycled (Qr/Go) (Equation (17.4)) is calculated from biomass mass balance of secondary settlement tank:
(Go +Qr)X = (Go - Gw)^e + (Gr + Gw)^w G o ^ ~ Gw^w
^ w
^
(17.34)
Qr =
(17.35) ^ ^
Go
13 500
(f) Calculate the f/m ratio using Equation (17.30): L = QoSo_ ^ 13 500 X 0.280 ^ 3780 ^ ^ ^9 m VX 3761X 3.5 13 163.5 Different design and operating parameters are used for plug-flow systems such as oxidation ditches, and these are reviewed by Benefield and Randall (1980). Completely mixed systems are widely used as they are comparatively cheap to construct. They tend to employ vertical surface aerators. Tanks are normally square in cross section with a flat base, 3-6 m in depth with a free board of 1.0-1.5 m to contain spray. Plug-flow systems are generally of the oxidation ditch type (Fig. 17.11).
463
17.5
COMMON MODIFICATIONS
1 ^
FIGURE
17.12
Feed
t1 1
M
k^
k
'
Mk
i ii
k i
^ J Effluent
Settlement tank
Feed
i\
i
Contact tank
^ ii
-*ry^
yr ^
Returned sludge Excess sludge
Settlement tank
Sludge recycle
FIGURE 17.13
A
Air
'r
\r
}r
^'
SI abilization ta Ik
464
flow as is the case with other systems and this results in up to 50% less aeration capacity required. This leads to a significant saving in both capital and aeration costs. There is less sludge produced by the process due to endogenous respiration and the sludge is of better quality. Once oxidation is complete the biomass is returned to the contact tank (Section 17.7). A separate tank is required for completely mixed systems or a zone for plug-flow systems (Fig. 17.14).
<
Stabilization zone Contact zone Effluent
FIGURE 17.14 Schematic flow diagram of a single basin contact stabilization activated sludge system.
T
Feed Returned sludge
Settlement tank
<
Excess sludge
FIGURE
17.15
Effluent Feed -
Schematic flow diagram of step aeration in a conventional plug-flow activated sludge system.
465
occur in separate tanks. However, renewed interest in batch operation has led to the introduction of sequencing batch reactors (SBR) systems. Using a single tank the sequence of events outlined in Fig. 17.16 is carried out repeatedly, with each complete cycle taking between 4 and 48 h with the SRT varying from 15 to 70 days. The f/m ratio will vary according to the length of the cycle but typically ranges from 0.03 to 0.18. The tanks permit better operation and allow precise control over periods when the mixed hquor can be allowed to become anoxic to permit denitrification (Section 18.4).
Stage I Wastewater addition Cycle 25% Volume increased from 25% to 100% Fill
Air off/on
Air on
Stage IV Effluent removal Cycle 15% Volume decreases from 100% to 35%
Air off
Air off
Stage V Sludge wastage Cycle 5% Volume decreases from 35% to 25% FIGURE 17.16 Sludge wastage Air off
466
systems. The ICI deep shaft process requires only 20% of the land space that a conventional activated sludge system requires (Fig. 17.17). For example, at Tilbury in London, a deep shaft system treats a population equivalent to 350000 on an area of 100 X 200 m. The process consists of a deep well of between 30 and 220 m and 0.8-6 m in diameter. The advantage is the high hydrostatic pressure at the base of the shaft gives a very high oxygen solubility with little power requirement. At a sludge loading of 0.8-1.0 kg kg"May"\ the process achieves a BOD removal of 95% although solids are high, a factor that is less important in coastal disposal. No primary sedimentation is required, although the influent must be carefully screened before entering the system due to the potential accumulation of dense solids at the base of the shaft. The HRT is only 1.1-1.8 h, making this process capable of treating high hydraulic load. The A-B process is widely used in the Netherlands and Germany. It is two separate activated sludge plants operated in series. A highly loaded first (A) stage at a sludge loading of 3-6kgkg"^ day"^ to give 70% BOD removal. This is followed by a lowloaded second (B) stage at a loading of 0.15-0.3 kg kg~May"^ to give a high purity fully nitrified effluent (Fig. 17.18). It uses only 60% of the conventional aeration tank
Settled wastewater Sludge return
Sedimentation
c-
z'
.V
Start-up air
Degassing
Effluent
Process air
1^
Waste sludge
FIGURE
17.17
Schematic diagram of the deep shaft process developed by ICI pic employing a U-shaped reaction shaft.
^
Second (B) stage
Effluent
FIGURE
17.18
The A-B activated sludge process. AT: aeration tank; ST: sedimentation tank.
Excess sludge
Excess sludge
17.6 Ecology
467
capacity resulting in a capital saving of 30%, and 20% lower aeration costs. Owing to their size both plants can be covered, and odours and pathogens removed by scrubbing, making them ideal for residential areas.
17.6
ECOLOGY
Like all biological treatment processes the activated sludge system relies on a mixed culture of bacteria to carry out the basic oxidation of the substrate with higher grazing organisms such as protozoa and rotifers also present, forming a complete ecosystem with several trophic levels (Fig. 17.19). The activated sludge aeration tank is a truly aquatic environment, although the high substrate concentration and high level of bacterial activity make it unlike any natural environment. The constant aeration and re-circulation of sludge makes it inhospitable for most aquatic species, especially those larger than the smaller mesofauna such as rotifers and nematodes, or animals with long life cycles. In comparison to a percolating filter, where the substrate flows over a thin film attached to an inert medium, and where a diverse macro-invertebrate grazing fauna is found, the activated sludge system is much simpler, with fewer trophic levels forming simple food webs. As the floe ages it becomes colonized by bacterial feeding organisms such as ciliate protozoa, nematodes and rotifers. Active bacteria are restricted to the outer surface of the floes with distinct oxygen and substrate gradients towards the centre of each floe. With long sludge ages the slower growing bacteria such as the nitrifiers will also colonize the
Nematodes rotifers
Excess sludge
FIGURE 17.19
Food pyramid representing feeding relationships in the activated sludge processes: synthesis, > ^degradation (reproduced from Hawkes (1983) with permission of Academic Press Ltd, London).
Organic waste
Effluent
468
Chapter 17 / Activated Sludge floes. As thefloesage the rate of oxidation gradually declines and in olderfloesmost of the bacteria are non-viable, although they retain active enzyme systems and continue to excrete extra-cellular enzymes. Material continues to be adsorbed onto olderfloes.An important selective factor is that only the species of bacteria capable of forming compactfloeswill settle out in the sedimentation tank, and so will be returned as sludge to the aeration tank. Those bacteria unable toflocculateare lost with the final effluent.
17.7
469
470
Small, comj)act, weak, roughly spherical floes are formed the larger of which settle rapidly. Smaller aggregates settle slowly Filamentous organisms extend from floes into the bulk solution and interfere with compaction and settlino of activated sludofe
Bulking
High SVI - very clear supernatant. Low RAS and WAS solids concentration. In severe cases overflow of sludge blanket occurs. Solids handling processes become hydraulically overloaded A scum of activated sludge forms on surface of secondarv clarifier
Blanket rising
Denitrification in secondary clarifier releases poorly soluble nitrogen gas which attaches to activated sludge floes and floats them to the secondary clarifier surface Caused by (i) non-degradable surfactants and (ii) by the presence of Nocardia sp. and other foam-associated species
Foams float large amounts of activated sludge solids to surface of treatment units. Nocardia and Microthrix foams are persistent, and difficult to break mechanically. Foams accumulate and can purify. Solids can overflow into secondary effluent or even overflow out of the tank free board onto walkways
Reproduced from Jenkins et al. (1984) with permission of Water Research Commission, Pretoria, South Africa.
aeration tank. Floes generally settle quickly while the smaller sheared pieces are lost with thefinaleffluent. Macrostructure is wherefloebacteria aggregate around filaments that provide a type of backbone or support. This makes floes larger, stronger and irregular in shape.
471
TABLE 17.4
Distinguishing sludge problems from other solid-liquid separation problems Bulking Pin floe Deflocculation Floes formed Filaments present Supernatant clear High SVI Rising sludge that covers surface Turbid effluent due to small particles Yes Yes Yes Yes No No Yes No No Possibly No Yes No No No Possibly No Yes Denitrification Yes No Possibly Possibly Yes No
The main sludge problem involving microstructure is deflocculation where bacteria fail to form floes, or weak floes are broken up by overaerating causing excessive shear. If not controlled then it becomes progressively difficult to maintain the desired MLSS concentration in the aeration tank, with the f/m ratio increasing as a consequence. When sludge is essentially microstructural in nature then deflocculation is caused by low DO, low pH, shock loadings or sludge loadings >0.4 kg kg~^ day~^ If a sludge has a microstructure then a high sludge loading will eventually cause deflocculation to occur. Deflocculation is characteristic of toxic or inhibitory wastewaters, especially those in the pharmaceutical and allied chemical industries. The common macrostructural problem is bulking which occurs when filamentous micro-organisms extend from thefloeinto the bulk solution (Table 17.4). This interferes with the settlement offloesand subsequent compaction of the sludge so that a much thinner sludge is returned to the aeration tank with a low MLSS. It becomes progressively more difficult to maintain the desired MLSS concentration in the aeration tank, which will gradually fall leading to a decline in effluent quality as the f/m ratio increases. The ideal floe has an SVI of between 50 and 120mlg~^ and the final effluent is free from suspended solids and turbidity. The filaments andfloc-formingspecies are balanced withfilamentslargely contained within thefloegiving it strength and a definite structure. While there may be discernible filaments protruding from floes these will be sufficiently scarce and of reduced length not to interfere with settlement. In contrast, bulking floes, where the SVI is >150mlg~^ and the final effluent is gradually increasing in turbidity and suspended solids, large numbers offilamentswill protrude from floes. These will reduce settling velocity in the sedimentation tank, raise the level of the sludge blanket so that the sludge is uncompacted and thin, and eventually result infloesbeing washed out of the sedimentation tank with the final effluent. Two types of bulking floes are discernible: fairly compact floes with long filaments growing out of the floes and linking individual floes together (bridging), forming a mesh-work of filaments and floes and floes with a more open (diffuse) structure which is formed by bacteria agglomerating along the length of the filaments forming thin, spindlyfloesof a large size (Fig. 17.20). The type of floe formed, the type of compaction and settling interference caused depends on the type offilamentousmicro-organisms present. Bulking is predominately
472
a-
0
^ ^
CO
'^
r^#
o
Eo i5 E
H= Q.
Q-
Ideal floe structure, Irregular and large, strong and open, filament growth largely contained, with filaments providing support for floe development
0 C0T3
FIGURE 17.20
Diffuse floe structure with large irregular open floes developing along filaments
Filaments growing from large, strong floes which join to form bridges
caused by bacterial filaments with bridging caused by types 02IN, 0961, 0805, 0041, Sphaerotilus nutans, Thiothrix sp. and Haliscomenobacter hydrossis. While open floe structure is associated with type 1701, 0041, 0675, Nostocoida limicola and Microthrix parvicella. Twenty-five different bacteria are commonly recorded, also fungi and algae are also known to occasionally cause bulking. Types 0041, 021N, Nocardia, M. parvicella and H. hydrossis are particularly common bacterialfilamentswith a worldwide distribution (Table 17.5).
473
TABLE 17.5
The most frequently occurring filamentous micro-organisms recorded in activated sludge plants in various countries Rank 1 2 3 4 5 6 7 8 9 10 USA Nocardia 1701 021N 0041 Thiothrix S. natans M. parvicella 0092 H. hydrossis 0675 The Netherlands Germany 021N M. parvicella 0041 S. natans Nocardia H. hydrossis N. limicola 1701 0961 0803 South Africa 0092 0041 0675 Nocardia M. parvicella 1851 0914 0803 A^. limicola 021N Ireland 0041 021N M. parvicella 0675 A^. limicola 1851 Fungi 1701 H. hydrossis 0803
M. parvicella 021N H. hydrossis 0092 1701 0041 S. natans 0581 0803 0961
of an impending problem can be obtained by the presence offilamentsin the sludge, change in sludge morphology and ecology, a gradual increase in the SVI or an increased turbidity of the final effluent. Sludge settleability If a steady increase in the measured SVI (SSVI) occurs over time moving towards and exceeding 120mlg~^ (180mlg"^) then bulking is imminent, and remedial action should be taken. Cone test During the measurement of SVI or SSVI the supernatant should be examined. The sludge should form a discrete blanket with a clear supernatant. If the sludge volume is >650ml (SVI only) with a clear supernatant then bulking should be suspected, but if the supernatant is turbid then another sludge problem should be considered (e.g. deflocculation, pinpoint floe) (Table 17.4). Floe morphology The floe morphology can tell us a lot about the state of the sludge (e.g. micro- or macrostructure). The protozoa may also help to rapidly identify such operational problems as organic overloading, underaeration or insufficient SRT (Table 17.6). It is very difficult to identify the bacteria in activated sludge to species level, for this reason typing is used. Thefilamentscausing bulking may have more than one growth form and so are considered different types, while some types may contain two or more distinct species. Thefilamentousbacteria associated with activated sludge and with bulking and foaming can be readily identified using the detailed key by Eikelboom and van Buijsen (1981) which uses just three staining techniques, the Gram, Neisser and sulphur storage tests.
474
TABLE 17.6
Lightly loaded
Small compact floes Ciliates present in small numbers Typical species Vorticella communis Epistylis rotans Stentor roeseli Amoebae (testate) Rotifers and nematodes present Suctorians abundant
Irregular floes Ciliates present in large numbers Typical species Vorticella convallaria Opercularia coarctata Aspidisca costata Euplotes ajfinis Flagellates present in small number Amoebae present in small numbers
along with morphological features (Fig. 17.21). Jenkins et al (1984) have extended this key making use of three more simple stains, the Indian ink reverse, poly-(3hydroxybutrate and crystal violet sheath stains to aid identification. Identification and assessment of micro-organisms can be aided by the use of a simple record sheet. A standard record sheet for observations, not only of the bacterial types present but also of the other flora and fauna, as well as floe morphology, is also recommended (Jenkins et al, 1984). By examining a large number of bulking sludges, dominant bulking organisms have been related to various operational parameters. Clear associations have become evident so that the presence of various species can be used with some degree of accuracy to indicate causative operational problems of bulking. For example, fungi is associated with wastewater which has a strong acidic discharge that reduces the pH in the aeration tank; type 1701 and S. nutans indicates low DO due to a high sludge loading; M. parvicella thrives during periods or in regions of low DO, but not anoxic or anaerobic, under long sludge age conditions where the f/m ratio is low (Table 17.7).
Filament counting For rapid assessment a subjective index should be used. The degree of filamentous development is ranked against a series of drawings/photographs at lOOX magnification (Fig. 17.22). Counting numbers or lengths of filaments are more quantitative but no more accurate in terms of prediction, but very much more time consuming. The total extended filament length (TEFL) is measured by taking 2 ml of mixed liquor, which is diluted and mixed with 11 of distilled water, a dilution factor of 500. Subsamples of 1 ml are placed on a slide and all filaments in that sample are measured and counted. The length of filaments can be estimated rapidly by placing them into various size categories, for example 0-10, 10-25, 25-50, 50-100, 100-200, 200-400 and 400-800 ixm, while all filaments >800 ixm in length should be measured individually. The TEFL is then calculated as either: Total length of filaments X dilution factor fjim ml ^ (TEFL per ml MLSS) (17.36)
col
< ^
00
\zi
1
^
CD
ol o
T T^
of
J O C D
fl
t
P Q
cri
OJ CT!
'3
1^
I
C :^ D - TO C
CD -^
C 0 D
-1
o o
"co "w iG
3 <D 0)
I CD D
5 "o *=
CO S
a
o o
.0
dJ
SZ
0) 0) CO
O d
0) in
CD
w is O w
CO o Q- C B E C O D .52 T3
^C C < D Oj i^ > C ^ D
- B c c O CD to F
^ 2 o O -D i5
Q. O ^ J
o gc
1c
CJ C D C i: D
^
CO o ; ^
<D CO
V
p
COP
_ca 0)
2g = w 2
ill.
S C E O 2 0) g O P iE
0
C 3 O O) O Q.
I ^22 2 ^
li
<D 1 -
t
(D O 0 ,
o
^
O V
t
E C O <o =
!. n
^E
CD CD -
*r
zB
c ir
CpL CO
E CD CO =
1
o 3 O "^ O
Hi
CO S
8.J
C !o D
XI
o
CJ) i_
0 ^
"Z. B
^^
3
O)
*^
o
0 Q.
F
C O CD
E
O
CD
C D
i_4
C/3
I E ^
^i
O S
ti
CO 5.^
D (O X)
E CO
S a:)
rf)
CO ^
^
o o .E ^
a
%CO CO
^ ^ a:)
d")
_l
IJ_
S CO.- V C i_ 0 C O Q 5 ^ fli CO
Z
< O 0) D > (0 n
2 6
^0 ^
<D
C i2 D
O C O O
C**
^ I .^ s "^ ^
= C - ^ - ^ ^ O 0
oo-ii
il E:
E^^ c E
O C D
V
O C D =
cd
O-o o ) ^
o w
5 C O
P o 2 $ c
UJ CO C3)
2 S
o E ic
. 0
i2 c
C 0 D
w C D
DC CO
igi
CD O i ^
OH
S 00
476
TABLE 17.7
The use of dominant filament type as indicators of conditions causing activated sludge bulking Suggested causative Low DO Low f/m Septic waste water/sulphide Nutrient deficiency Low pH conditions Indicative filament types
Type 1701, S. nataris, H. hydrossis, M. parvicella M. parvicella, H. hydrossis, Nocardia sp. tvpes 021N, 004L 0675, 0092, 0581, 0961, 0803 Thiothrix sp., Beggiatoa sp. and type 02IN Thiothrix sp., *. natans type 02IN and possibly H. hydrossis and types 0041 and 0675 Fungi
Reproduced from Strom and Jenkins (1984) with permission of the Water Pollution Control Federation, Washinofton, DC.
FIGURE
17.22
Filament abundance categories using a subjective scoring index where (a) few, (b) some, (c) common, (d) very common, (e) abundant and (f) excessive. Photographs are at lOOX with the bar indicating 100 jjim. (Reproduced from Jenkins e/: a/. (1984) with permission of the Water Research Commission, Pretoria, South Africa).
477
or
Total length of filaments X dilution factor MLSS(gl-i) (17.37) Good correlations have been obtained between SVI and TEFL. A simpler and quicker method uses a 40 jxl sub-sample of mixed Uquor that is placed on a standard glass slide and covered with a 22 X 22 mm cover slip. The number of separate fields required to examine the entire area under the cover slip once at 100 X is calculated, which remains constant for any specific microscope (e.g. 144). Then using an eyepiece containing a single hairline graticule, the number of times any filament intersects with the hairline is counted (Equation (17.38)). This is repeated at least 20 times although the exact number depends on time and the desired level of precision: C X 144 Total filament length = ^jim (17.38) . , . /rr^i-T-T A r oo\ >T am g M ^ (TEFL per g MLSS)
40X20
where C is the sum of all the intersection, 40 is the sub-sample size in jxl, 144 the number offieldsof vision per sHde and 20 is the number of times the count is repeated.
17.8
REMEDIAL MEASURES
In essence some alteration in operational practice is required to control sludge bulking. Specific control measures include operational control, chemical addition or process modification (in increasing order of investment and cost).
Dissolved oxygen Underaeration will result in bulking so the aeration tank requires automatic DO control to ensure at least 10% oxygen saturation for carbonaceous or 20% saturation for nitrification. The greatest demand will be at the inlet. Overaeration results in deflocculation due to shear.
478
Chapter 17 / Activated Sludge Septicity of sewage This is due to anaerobosis during passage in the sewer and can be overcome by oxygen injection or the revision of sewer design. Anaerobosis in primary sedimentation tanks is controlled by increasing the desludging rate. Nutrient balance A BOD:N:P ratio of 100:5:1 is needed to prevent bulking. Raw sewage is rich in N and P, while pharmaceutical, chemical and some food-processing industries are low in nutrients. Agricultural fertilizers are generally used to supplement N and P, while urea is used for N only. Nature of substrate If toxic substances are present then pre-treatment is required (Section 14.3). Lowmolecular-weight carbohydrates encourage bulking, so roughing treatment using biotowers or biological aerated filters (Section 14.4) before the aeration tank is required. Controlling sludge loading ratio To avoid bulking the f/m ratio should be maintained between 0.2 and 0.45kgkgday~^ The f/m can be altered by adjusting: (a) the BOD strength andflowrate; (b) aeration tank volume; (c) the MLSS concentration. In practice only the MLSS concentration is easily altered. So reducing the MLSS by wasting sludge increases the f/m, while increasing the MLSS in the aeration tank by not wasting sludge will reduce the f/m ratio. A minimum MLSS concentration of 2000 mgT ^ is required, the upper limit depending on the aeration capacity and ability of the sedimentation tank to handle the sludge.
479
then the biocide will have maximum effect on filaments and minimum effect on the aggregated floc-forming bacteria. The dosing rate is critical, so it is best to start at a low concentration and slowly increase the dose. The most widely used biocides are chlorine or its derivatives (e.g. sodium hypochlorite) that are toxic at low concentrations, while hydrogen peroxide and ozone are very reactive and add oxygen to the aeration tank as they decompose.
Flocculants Flocculants are metal salts or polyelectrolytes used to improve flocculation and settleability, as well as floe strength. If a metal salt is used (e.g. aluminium sulphate (alum) or ferric chloride) this can be added directly to tank. Some phosphorus removal also occurs, but there is a significant increase in metal salts. Polyelectrolytes have such a rapid response they must be added to the overflow stream as it enters the sedimentation tank (Section 20.5).
Mixing pattern The more plug flow the configuration of the system, then the better the sludge settleability. Plug flow reduces the competitive advantage that filaments have over floc-forming bacteria due to their high surface area to volume ratio, which makes them more efficient when substrate, nutrients or DO concentrations are low (i.e. accumulation-regeneration theory). A concentration gradient in a plug-flow reactor ensures that initially soluble substrate is rapidly absorbed and stored within cells in the high-concentration area of the reactor (accumulation). Bacteria can then subsequently proceed to digest the material and produce new cells (regeneration). Linked to a high specific growth rate and selection in the sedimentation tank, this ensures that floe formers dominate. In completely mixed reactors where there is no concentration gradient and the substrate concentration is uniformly low, filaments have the competitive advantage over floe formers. The optimum size for a longitudinal tank is a length to width ratio of 20:1.
Selector A selector also uses the accumulation-regeneration system. A special tank or zone is provided that is rich in nutrients and oxygen where the most efficient micro-organisms absorb the bulk of the substrate under high substrate concentration. This favours the floe formers. The main aeration tank has a much lower substrate concentration, ensuring a concentration gradient (Fig. 17.23) (Gabb et ai, 1991).
480
The incorporation of a contact tank in a completely mixed system or a contact zone in a plug-flow system.
Effluent
Anoxic zones Anoxic zones are mainly used for denitrification but have been found to improve sludge settleability (Section 18.4.1).
REFERENCES
Alleman, J. E. and Prakasam, T. B. S., 1983 Reflections on seven decades of activated sludge history, Journal of the Water Pollution Control Federation, 55, 436-43. Benefield, L. D. and Randall, C. W., 1980 Biological Process Design for Wastewater Treatment, Prentice-Hall, New York. Chambers, B. and Jones, G. L., 1988 Optimization and uprating of activated sludge plants by efficient process design. Water Science and Technology, 20 (4/5), 121-32. Cloete, T. E. and Muyima, N. Y. O. (eds), 1997 Microbial Community Analysis: The Key to the Design of Biological Wastewater Treatment Systems, Scientific and Technical Report No. 5, International Association on Water Quality, London. Coackley, P. and O'Neill, J., 1975 Sludge activity and full-scale plant control, Water Pollution Control, 74, 404-12. Cox, G. C, ColHns, O. C. and Everett, D. A. H., 1982 Works construction and operation in the UK. In: Oxidation Ditch Technology. International Conference, Amsterdam, C.E.P. Consultants, Edinburgh, pp 98-110. DOE, 1985 The Conditionability, Filterability, Settleability and Solids Content of Sludges 1984. {A Compendium of Methods and Tests), Methods for the Examination of Waters and Associated Materials, Department of the Environment, HMSO, London.
Further Reading
481
Eikelboom, D. H. and van Buijsen, H. J. J., 1981 Microscopic Sludge Investigation Manual, TNO Research Institute for Environmental Hygiene, Delft. Gabb, G. M. D., Still, D. A , Ekama, G. A., Jenkins, D. and Marais, G. V. R., 1991 The selector effect on filamentous bulking in long sludge age activated sludge systems. Water Science and Technology, 23 (4/5), 867-77. Gray, N. R, 2004 Biology of Wastewater Treatment, 2nd edn. Imperial College Press, London. Hawkes, H. A., 1983 Activated sludge. In: Curds, C. R. and Hawkes, H. A., eds. Ecological Aspects of Used Water Treatment: 2. Biological Activities and Treatment Processes, Academic Press, London, pp 77-162. lAWQ, 1995 Activated Sludge Model No. 2, Scientific and Technical Report No. 3, International Association on Water Quality, London. IWPC, 19^1 Activated Sludge, Institute of Water Pollution Control, Maidstone. Jenkins, D., Richard, M. G. and Daigger, G. T, 1984 Manual on the Causes and Control of Activated Sludge Bulking and Foaming, Water Research Commission, Pretoria, South Africa. Rachwal, A. J. and Waller, C. B., 1982 Towards greater efficiency. In: Oxidation Ditch Technology. International Conference, Amsterdam, October 1982, C.E.P. Consultants, Edinburgh, pp 151-60. Strom, P. F. and Jenkins, D., 1984 Identification and significance of filamentous micro-organisms in activated sludge, Journal of the Water Pollution Control Federation, 51, 2829-40. Wagner, M. and Amann, R., 1997 Molecular techniques for determining microbial community structures in activated sludge. In: Cloete, T. E. and Muyima, N. Y. O., Qds, Microbial Community Analysis: The Key to the Design of Biological Wastewater Treatment Systems, Scientific and Technical Report No. 5, International Association on Water Quality, London, pp 61-72. White, M. J. D., 1975 Settling of Activated Sludge, Technical Report No. 11, Water Research Centre, Stevenage. Winkler, M. A., 1981 Biological Treatment of Waste Water, EUis Horwood, Chichester.
FURTHER READING
Albertson, O. E., 1991 Bulking sludge control - progress, practice and problems. Water Science and Technology, 23 (4/5), 835-46. Eckenfelder, W W and Grau, P., eds, 1992 Activated Sludge Process Design: Theory and Practice, Technomic Publishing, Lancaster, PA. Gray, N. K, 2004 Biology of Wastewater Treatment, 2nd edn. Imperial College Press, London. Jenkins, D., Richard, M. G. and Daigger, G. T, 1993 Manual on the Causes and Control of Activated Sludge Bulking and Foaming, Lewis Publishers, Boca Raton, FL. Madoni, P. (ed.), 1991 Biological Approach to Sewage Treatment Processes: Current Status and Perspectives, Lugi Bazzucchi Center, Perugia, Italy. Mara, D. and Horan, N. (eds), 2003 The Handbook of Water and Wastewater Microbiology. Academic Press, London. Mines, R. O. and Sherrard, J. H., 1999 Temperature interactions in the activated sludge process. Journal of Environmental Science and Health, A34, 329-40.