Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Rev 1
CONTENTS PAGE NO
1.0 INTRODUCTION........................................................................................................................................................... 3
1.1 GENERAL ....................................................................................................................................................................... 3
1.2 DESIGN PHILOSOPHY ..................................................................................................................................................... 3
1.3 REFERENCES .................................................................................................................................................................. 3
2.0 INPUT LOAD CALCULATION................................................................................................................................... 4
2.1 DEAD LOAD ......................................................................................................................................................................... 4
2.2 LIVE LOAD (LL) ............................................................................................................................................................ 4
2.3 WIND LOAD (WL) ......................................................................................................................................................... 5
2.4 SEISMIC LOAD ............................................................................................................................................................... 8
3.0 VIEWS ................................................................................................................................................................................. 10
3.1 ISOMETRIC VIEW ............................................................................................................................................................... 10
3.2 NODE NUMBERS & BEAM NUMBERS ................................................................................................................................. 10
3.4 STAAD INPUT ..................................................................................................................................................................... 11
4.0 DESIGN CALCULATION ................................................................................................................................................ 16
4.1 SLAB DESIGN .................................................................................................................................................................... 16
4.2 DESIGN OF BEAM ......................................................................................................................................................... 19
4.2.1 PLINTH BEAM @ EL +99.95 (PB1) ................................................................................................................................ 19
4.2.2 PLINTH BEAM @ EL +99.95 (PB2) ................................................................................................................................ 20
4.2.3 ROOF BEAM @ EL +103.00 (RB1) .......................................................................................................................... 20
4.2.4 ROOF BEAM @ EL +103.00 (RB2) ......................................................................................................................... 20
4.3 DESIGN OF FOOTING ................................................................................................................................................... 21
5.0 STAAD OUTPUT ............................................................................................................................................................... 26
5.1 DESIGN OF COLUMNS......................................................................................................................................................... 26
5.2 SUPPORT REACTIONS ................................................................................................................................................... 30
5.3 BEAM – SECTION FORCES ............................................................................................................................................ 33
6.0 CONCLUSION ................................................................................................................................................................... 34
DESIGN CALCULATIONS FOR GUARD ROOM - SV1 STATION AT BODI GHODI Page 2 of 34
MAYTAS NAFTOGASBUD JV GSPL203-73-1506
Rev 1
1.0 INTRODUCTION
1.1 General
The objective of this document is to define the minimum requirements for the design and
engineering of the BHARUCH JAMNAGAR PIPELINE PROJECT. The general scope of work is for
engineering procurement and construction of the Bharuch Anand– GSPL pipeline system and
related facilities including Despatch Station, SV Stations, Tap-off station and receiving station.
This pipeline broadly consists of approximately 103.50 KMs of 30” line pipe from existing station
(Receiving Station) at rajkot on GSPL 24” Anand Rajkot Pipe-line to village Pipli at chainage
89.67 Km (Receiving Station at Jamnagar) and subsequently to Reliance Receiving Station (at
Reliance premises)
The purpose of this document is for providing the Design and Details of Guard Room for SV1
Station in Bodi Ghodi at Chainage 21.75 Km.
1.3 References
IS : 456-2000 Code of practice of plain and reinforce concrete.
IS 1905-1987 Code of Practice for Structural Use of Un-reinforced Masonry
SP -16 Design Aids for Reinforced Concrete to IS:456-1978
. IS : 875-1987 (Parts I to V) Code of practice for Design loads (other than earthquake) for
Buildings and Structures
IS : 1893 Pt.I-2002 Criteria for Earthquake Resistant Design of Structure.
IS :13920 Code of practice for ductile detailing of RCC Structures subjected to
Seismic forces
Job 7/06-07 Geotechnical/Soil Investigation Report of M. K.. Soil Test Laboratory,
Ahmedabad-7
DESIGN CALCULATIONS FOR GUARD ROOM - SV1 STATION AT BODI GHODI Page 3 of 34
MAYTAS NAFTOGASBUD JV GSPL203-73-1506
Rev 1
The loads applied on the structure are Dead Loads, Live Loads , Wind Loads & Seismic loads in
both the directions
DESIGN CALCULATIONS FOR GUARD ROOM - SV1 STATION AT BODI GHODI Page 4 of 34
MAYTAS NAFTOGASBUD JV GSPL203-73-1506
Rev 1
θ
A B
Windward Leeward
Side Side
X
Z D
h/w (3.58/2.5 ) = 1.432
l/w (3.5/2.5) = 1.4
0.5 < h/w < 1.5
1< l/w < 1.5
DESIGN CALCULATIONS FOR GUARD ROOM - SV1 STATION AT BODI GHODI Page 5 of 34
MAYTAS NAFTOGASBUD JV GSPL203-73-1506
Rev 1
1.2 0.25
A D
0.7 -0.25
+0.5
0.2 0.75
A D
DESIGN CALCULATIONS FOR GUARD ROOM - SV1 STATION AT BODI GHODI Page 6 of 34
MAYTAS NAFTOGASBUD JV GSPL203-73-1506
Rev 1
Load Case 3: WL: +X (90' IS)
Wind Angle = 90'
B C
A D
0.2 0.75
A D
DESIGN CALCULATIONS FOR GUARD ROOM - SV1 STATION AT BODI GHODI Page 7 of 34
MAYTAS NAFTOGASBUD JV GSPL203-73-1506
Rev 1
For Seismic Analysis, following factors has been considered as per IS 1893-2002 Pt.I
Factored Load
1.5DL+1.5LL
1.5DL+ 1.5EQ:+X
1.5DL+ 1.5EQ:+Z
0.9DL+ 1.5EQ:+X
0.9DL+ 1.5EQ:+Z
1.5DL+ 1.5WL:+Z (0' IS)
1.5DL+ 1.5WL:+Z (0' IP)
1.5DL+ 1.5WL:+X (90' IS)
1.5DL+ 1.5WL:+X (90'IP)
0.9DL+ 1.5WL:+Z(0' IS)
0.9DL+ 1.5WL:+Z(0' IP)
0.9DL+ 1.5WL:+X(90' IS)
0.9DL+ 1.5WL:+X(90' IP)
1.2DL+1.2LL+1.2EQ:+X
1.2DL+1.2LL+1.2EQ:+Z
1.2DL+1.2LL+1.2WL:+Z(0' IS)
1.2DL+1.2LL+1.2WL:+Z(0' IP)
1.2DL+1.2LL+1.2WL:+X(90' IS)
1.2DL+1.2LL+1.2WL:+X(90' IP)
1.5DL+ 1.5EQ:-X
1.5DL+ 1.5EQ:-Z
0.9DL+ 1.5EQ:-X
0.9DL+ 1.5EQ:-Z
1.5DL+ 1.5WL:-Z (0' IS)
1.5DL+ 1.5WL:-Z (0' IP)
DESIGN CALCULATIONS FOR GUARD ROOM - SV1 STATION AT BODI GHODI Page 8 of 34
MAYTAS NAFTOGASBUD JV GSPL203-73-1506
Rev 1
Un Factored Load
1.0DL+1.0LL
1.0DL+ 1.0EQ:+X
1.0DL+ 1.0EQ:+Z)
1.0DL+ 1.0WL:+Z(0'IS)
1.0DL+ 1.0WL:+Z(0'IP)
1.0DL+ 1.0WL:+X(90'IS)
1.0DL+ 1.0WL:+X(90'IP)
1.0DL+1.0LL+1.0EQ:+X
1.0DL+1.0LL+1.0EQ:+Z
1.0DL+1.0LL+1.0WL:+Z(0'IS)
1.0DL+1.0LL+1.0WL:+Z(0'IP)
1.0DL+1.0LL+1.0WL:+X(90'IS)
1.0DL+1.0LL+1.0WL:+X(90' IP)
1.0DL+ 1.0EQ -X
1.0DL+ 1.0EQ:-Z)
1.0DL+ 1.0WL:-Z(0'IS)
1.0DL+ 1.0WL:-Z(0'IP)
1.0DL+ 1.0WL:-X(90'IS)
1.0DL+ 1.0WL:-X(90'IP)
1.0DL+1.0LL+1.0EQ:-X
1.0DL+1.0LL+1.0EQ:-Z
1.0DL+1.0LL+1.0WL:-Z(0'IS)
1.0DL+1.0LL+1.0WL:-Z(0'IP)
1.0DL+1.0LL+1.0WL:-X(90'IS)
1.0DL+1.0LL+1.0WL:-X(90' IP)
DESIGN CALCULATIONS FOR GUARD ROOM - SV1 STATION AT BODI GHODI Page 9 of 34
MAYTAS NAFTOGASBUD JV GSPL203-73-1506
Rev 1
3.0 VIEWS
3.1 Isometric View
Y
X
Z Load 1
10
9 12
9
12
11 10 17
11
13
19
2
14 1 4
1 23
4
3 2
21 14
3 24
Y 13
22
X 16
Z Load 1
15
DESIGN CALCULATIONS FOR GUARD ROOM - SV1 STATION AT BODI GHODI Page 10 of 34
MAYTAS NAFTOGASBUD JV GSPL203-73-1506
Rev 1
DESIGN CALCULATIONS FOR GUARD ROOM - SV1 STATION AT BODI GHODI Page 11 of 34
MAYTAS NAFTOGASBUD JV GSPL203-73-1506
Rev 1
10 UMOM GX 0.135
9 UMOM GX -0.135
12 UMOM GZ -0.135
11 UMOM GZ 0.135
9 TO 12 UNI GY -0.45
****************************************************************************
LOAD 5 WL:+Z(0'IS)
MEMBER LOAD
17 UNI GZ 3.83
13 UNI GZ 3.83
19 UNI GZ -0.8
14 UNI GZ -0.8
9 UMOM GX 0.39
10 UMOM GX 0.39
9 10 UNI GZ 1.31
****************************************************************************
****************************************************************************
LOAD 6 WL:+Z(0'IP)
MEMBER LOAD
17 UNI GZ 0.64
13 UNI GZ 0.64
19 UNI GZ 2.39
14 UNI GZ 2.39
9 UMOM X 0.39
10 UMOM X 0.39
9 10 UNI GZ 1.31
****************************************************************************
****************************************************************************
LOAD 7 WL:+X(90'IS)
MEMBER LOAD
14 UNI GX 2.73
13 UNI GX 2.73
19 UNI GX -0.57
17 UNI GX -0.57
11 UMOM GZ -0.39
12 UMOM GZ -0.39
11 12 UNI GX 1.31
****************************************************************************
LOAD 8 WL:+X(90'IP)
MEMBER LOAD
14 UNI GX 0.46
13 UNI GX 0.46
19 UNI GX 1.71
17 UNI GX 1.71
11 UMOM GZ -0.39
12 UMOM GZ -0.39
11 12 UNI GX 1.31
***************************************************************************
**************FACTORED LOAD COMBINATION************************************
***************************************************************************
LOAD COMB 9 (1.5DL+1.5LL)
3 1.5 4 1.5
LOAD COMB 10 (1.5DL+ 1.5EQ:+X)
3 1.5 1 1.5
LOAD COMB 11 (1.5DL+ 1.5EQ:+Z)
3 1.5 2 1.5
LOAD COMB 12 (0.9DL+ 1.5EQ:+X)
3 0.9 1 1.5
LOAD COMB 13 (0.9DL+ 1.5EQ:+Z)
3 0.9 2 1.5
LOAD COMB 14 (1.5DL+ 1.5WL:+Z(0'IS))
3 1.5 5 1.5
LOAD COMB 15 (1.5DL+ 1.5WL:+Z(0'IP))
3 1.5 6 1.5
LOAD COMB 16 (1.5DL+ 1.5WL:+X(90'IS))
DESIGN CALCULATIONS FOR GUARD ROOM - SV1 STATION AT BODI GHODI Page 12 of 34
MAYTAS NAFTOGASBUD JV GSPL203-73-1506
Rev 1
3 1.5 7 1.5
LOAD COMB 17 (1.5DL+ 1.5WL:+X(90'IP))
3 1.5 8 1.5
LOAD COMB 18 (0.9DL+ 1.5WL:+Z(0'IS))
3 0.9 5 1.5
LOAD COMB 19 (0.9DL+ 1.5WL:+Z(0'IP))
3 0.9 6 1.5
LOAD COMB 20 (0.9DL+ 1.5WL:+X(90'IS))
3 0.9 7 1.5
LOAD COMB 21 (0.9DL+ 1.5WL:+X(90'IP))
3 0.9 8 1.5
LOAD COMB 22 (1.2DL+1.2LL+1.2EQ:+X)
3 1.2 4 1.2 1 1.2
LOAD COMB 23 (1.2DL+1.2LL+1.2EQ:+Z)
3 1.2 4 1.2 2 1.2
LOAD COMB 24 (1.2DL+1.2LL+1.2WL:+Z(0'IS))
3 1.2 4 1.2 5 1.2
LOAD COMB 25 (1.2DL+1.2LL+1.2WL:+Z(0'IP))
3 1.2 4 1.2 6 1.2
LOAD COMB 26 (1.2DL+1.2LL+1.2WL:+X(90'IS))
3 1.2 4 1.2 7 1.2
LOAD COMB 27 (1.2DL+1.2LL+1.2WL:+X(90'IP))
3 1.2 4 1.2 8 1.2
LOAD COMB 28 (1.5DL+1.5EQ:-X)
3 1.5 -1 1.5
LOAD COMB 29 (1.5DL+1.5EQ:-Z)
3 1.5 -2 1.5
LOAD COMB 30 (0.9DL+1.5EQ:-X)
3 0.9 -1 1.5
LOAD COMB 31 (0.9DL+1.5EQ:-Z )
3 0.9 -2 1.5
LOAD COMB 32 (1.5DL+ 1.5WL:-Z(0'IS))
3 1.5 -5 1.5
LOAD COMB 33 (1.5DL+ 1.5WL:-Z(0'IP))
3 1.5 -6 1.5
LOAD COMB 34 (1.5DL+ 1.5WL:-X(90'IS))
3 1.5 -7 1.5
LOAD COMB 35 (1.5DL+ 1.5WL:-X(90'IP))
3 1.5 -8 1.5
LOAD COMB 36 (0.9DL+ 1.5WL:-Z(0'IS))
3 0.9 -5 1.5
LOAD COMB 37 (0.9DL+ 1.5WL:-Z(0'IP))
3 0.9 -6 1.5
LOAD COMB 38 (0.9DL+ 1.5WL:-X(90'IS))
3 0.9 -7 1.5
LOAD COMB 39 (0.9DL+ 1.5WL:-X(90'IP))
3 0.9 -8 1.5
LOAD COMB 40 (1.2DL+1.2LL+1.2EQ:-X)
3 1.2 4 1.2 -1 1.2
LOAD COMB 41 (1.2DL+1.2LL+1.2EQ:-Z)
3 1.2 4 1.2 -2 1.2
LOAD COMB 42 (1.2DL+1.2LL+1.2WL:-Z(0'IS))
3 1.2 4 1.2 -5 1.2
LOAD COMB 43 (1.2DL+1.2LL+1.2WL:-Z(0'IP))
3 1.2 4 1.2 -6 1.2
LOAD COMB 44 (1.2DL+1.2LL+1.2WL:-X(90'IS))
3 1.2 4 1.2 -7 1.2
LOAD COMB 45 (1.2DL+1.2LL+1.2WL:-X(90'IP))
3 1.2 4 1.2 -8 1.2
**********************************************************************************************
***
*UNFACTORED LOAD
**********************************************************************************************
***
LOAD COMB 46 (1.0DL+1.0LL)
3 1.0 4 1.0
DESIGN CALCULATIONS FOR GUARD ROOM - SV1 STATION AT BODI GHODI Page 13 of 34
MAYTAS NAFTOGASBUD JV GSPL203-73-1506
Rev 1
LOAD COMB 47 (1.0DL+ 1.0EQ:+X)
3 1.0 1 1.0
LOAD COMB 48 (1.0DL+ 1.0EQ:+Z)
3 1.0 2 1.0
LOAD COMB 49 (1.0DL+ 1.0EQ:+X)
3 1.0 1 1.0
LOAD COMB 50 (1.0DL+ 1.0EQ:+Z)
3 1.0 2 1.0
LOAD COMB 51 (1.0DL+ 1.0WL:+Z(0'IS))
3 1.0 5 1.0
LOAD COMB 52 (1.0DL+ 1.0WL:+Z(0'IP))
3 1.0 6 1.0
LOAD COMB 53 (1.0DL+ 1.0WL:+X(90'IS))
3 1.0 7 1.0
LOAD COMB 54 (1.0DL+ 1.0WL:+X(90'IP))
3 1.0 8 1.0
LOAD COMB 55 (1.0DL+ 1.0WL:+Z(0'IS))
3 1.0 5 1.0
LOAD COMB 56 (1.0DL+ 1.0WL:+Z(0'IP))
3 1.0 6 1.0
LOAD COMB 57 (1.0DL+ 1.0WL:+X(90'IS))
3 1.0 7 1.0
LOAD COMB 58 (1.0DL+ 1.0WL:+X(90'IP))
3 1.0 8 1.0
LOAD COMB 59 (1.0DL+1.0LL+1.0EQ:+X)
3 1.0 4 1.0 1 1.0
LOAD COMB 60 (1.0DL+1.0LL+1.0EQ:+Z)
3 1.0 4 1.0 2 1.0
LOAD COMB 61 (1.0DL+1.0LL+1.0WL:+Z(0'IS))
3 1.0 4 1.0 5 1.0
LOAD COMB 62 (1.0DL+1.0LL+1.0WL:+Z(0'IP))
3 1.0 4 1.0 6 1.0
LOAD COMB 63 (1.0DL+1.0LL+1.0WL:+X(90'IS))
3 1.0 4 1.0 7 1.0
LOAD COMB 64 (1.0DL+1.0LL+1.0WL:+X(90'IP))
3 1.0 4 1.0 8 1.0
LOAD COMB 65 (1.0DL+1.0EQ:-X)
3 1.0 -1 1.0
LOAD COMB 66 (1.0DL+1.0EQ:-Z)
3 1.0 -2 1.0
LOAD COMB 67 (1.0DL+1.0EQ:-X)
3 1.0 -1 1.0
LOAD COMB 68 (1.0DL+1.0EQ:-Z )
3 1.0 -2 1.0
LOAD COMB 69 (1.0DL+ 1.0WL:-Z(0'IS))
3 1.0 -5 1.0
LOAD COMB 70 (1.0DL+ 1.0WL:-Z(0'IP))
3 1.0 -6 1.0
LOAD COMB 71 (1.0DL+ 1.0WL:-X(90'IS))
3 1.0 -7 1.0
LOAD COMB 72 (1.0DL+ 1.0WL:-X(90'IP))
3 1.0 -8 1.0
LOAD COMB 73 (1.0DL+ 1.0WL:-Z(0'IS))
3 1.0 -5 1.0
LOAD COMB 74 (1.0DL+ 1.0WL:-Z(0'IP))
3 1.0 -6 1.0
LOAD COMB 75 (1.0DL+ 1.0WL:-X(90'IS))
3 1.0 -7 1.0
LOAD COMB 76 (1.0DL+ 1.0WL:-X(90'IP))
3 1.0 -8 1.0
LOAD COMB 77 (1.0DL+1.0LL+1.0EQ:-X)
3 1.0 4 1.0 -1 1.0
LOAD COMB 78 (1.0DL+1.0LL+1.0EQ:-Z)
3 1.0 4 1.0 -2 1.0
LOAD COMB 79 (1.0DL+1.0LL+1.0WL:-Z(0'IS))
3 1.0 4 1.0 -5 1.0
DESIGN CALCULATIONS FOR GUARD ROOM - SV1 STATION AT BODI GHODI Page 14 of 34
MAYTAS NAFTOGASBUD JV GSPL203-73-1506
Rev 1
LOAD COMB 80 (1.0DL+1.0LL+1.0WL:-Z(0'IP))
3 1.0 4 1.0 -6 1.0
LOAD COMB 81 (1.0DL+1.0LL+1.0WL:-X(90'IS))
3 1.0 4 1.0 -7 1.0
LOAD COMB 82 (1.0DL+1.0LL+1.0WL:-X(90'IP))
3 1.0 4 1.0 -8 1.0
*********************************************************************************
*********************************************************************************
*********************************************************************************
PERFORM ANALYSIS
PRINT ANALYSIS RESULTS
START CONCRETE DESIGN
CODE INDIAN
FC 25000 MEMB 1 TO 4 9 TO 12 21 TO 24
FYMAIN 415000 MEMB 1 TO 4 9 TO 12 21 TO 24
DESIGN BEAM 1 TO 4 9 TO 12
DESIGN COLUMN 13 14 17 19 21 TO 24
END CONCRETE DESIGN
FINISH
DESIGN CALCULATIONS FOR GUARD ROOM - SV1 STATION AT BODI GHODI Page 15 of 34
MAYTAS NAFTOGASBUD JV GSPL203-73-1506
Rev 1
2
Total Factor Load = 9.75 kN/m
discontinuous discontinuous
2.27 m in lx-direction
DL + LL+FL
discontinuous discontinuous
3.27 m in ly-direction
DESIGN CALCULATIONS FOR GUARD ROOM - SV1 STATION AT BODI GHODI Page 16 of 34
MAYTAS NAFTOGASBUD JV GSPL203-73-1506
Rev 1
cl2
discontinuous
cs1 cs2
y
discontinuous 2.27 discontinuous
x
3.27
discontinuous
cl1
Note: Refer to Text Book "R.C Design by unnikrishna pillai & devdas menon"
αx x w x Lx
+ 2
Dead load '+ve' beinding moment, Mx+ =
= 4.37 kN m
αy x w x Lx
+ 2
Dead load '+ve' beinding moment, MY+ =
= 2.81 kN m
Dead load Shear force in X-dir Vu = w x lx /2
= 11.07 kN
Dead load Shear force in Y-dir Vu = w x ly /2
= 15.94 kN
2
(a) Area of Steel Mx+ = ( 0.5 fck/fy ) x [ 1-v( 1 - (4.6Mu/(fck x 1000 x d )) ) ] x 1000d
AstR = 129.05 mm2 / m
2
(b) Area of Steel My+ AstR = ( 0.5 fck/fy ) x [ 1-v( 1 - (4.6Mu/(fck x 1000 x d )) ) ] x 1000d
2
= 90.13 mm / m
DESIGN CALCULATIONS FOR GUARD ROOM - SV1 STATION AT BODI GHODI Page 17 of 34
MAYTAS NAFTOGASBUD JV GSPL203-73-1506
Rev 1
Shear Check
Vult = 24.25 KN
Depth k
300 1.00
275 1.05
Vu = 15.94 KN 175 1.25
150 1.30
Basic span depth ratio for S.S slab = 20 (From IS 456-2000 Clause :23.2.1.a)
fs = 0.58 x fy x Ast required / Ast provided
= 240.7 (Ast provided = Ast required)
(l/d)max = 40
(20x2.0)
(l/d)provided = 25.80
(2.27 X 1000)/88
DESIGN CALCULATIONS FOR GUARD ROOM - SV1 STATION AT BODI GHODI Page 18 of 34
MAYTAS NAFTOGASBUD JV GSPL203-73-1506
Rev 1
2
Live Load = 0.75 KN/m
2
BM due to Slab LL on overhang = 0.75x0.6 /2
= 0.135 KN.m
Total BM due to DL & LL = 1.935 KN.m
Depth of Slab =120 mm Eff. Depth = 120-20-8/2
= 96 mm
Mu/bd2 = 0.315
From SP 16, Tab 3, For M25, Pt = 0.099
Provide Min. Reinforcement = 0.12%
2
Reinforcement reqd. = 115.2 mm
Hence, # 8 @ 200 c/c is sufficient.
SHEAR DESIGN
Ast Pt
Vu at provided provided
τc τv τc max Check Stirrup Spacing Mini
Shear legs 0.75*d 300
SL NO support at at Dia Of stirrup Spacing Spacing Provided mm
KN support support N/mm
2
N/mm 2
N/mm 2 for τc mm
(Nos)
mm mm
mm mm
mm2 mm2
1 61.756 400 0.38 0.44 0.59 3.1 O.K 8 2 300.00 -- 339.00 300 300.00
DESIGN CALCULATIONS FOR GUARD ROOM - SV1 STATION AT BODI GHODI Page 19 of 34
MAYTAS NAFTOGASBUD JV GSPL203-73-1506
Rev 1
.
4.2.2 Plinth Beam @ EL +99.95 (PB2)
SHEAR DESIGN
Ast Pt
Vu at provided provided
τc τv τc max Check Stirrup Spacing Mini Spacing
Shear legs 0.75*d 300
SL NO support at at Dia Of stirrup Spacing Provided
KN support support N/mm
2
N/mm 2
N/mm 2 for τc mm
(Nos)
mm mm
mm mm
mm
2 2
mm mm
1 60.987 400 0.38 0.44 0.59 3.1 O.K 8 2 300.00 -- 339.00 300 300.00
SHEAR DESIGN
Ast Pt
Vu at provided provided
τc τv τc max Check Stirrup Spacing Mini
Shear legs 0.75*d 300 Spacing
SL NO support at at Dia Of stirrup Spacing
KN support support N/mm
2
N/mm 2
N/mm 2 for τc mm
(Nos)
mm mm
mm mm Provided mm
2 2
mm mm
1 36.189 400 0.38 0.43 0.34 3.1 O.K 8 2 -- 394.33 347.00 300 300.00
SHEAR DESIGN
Ast Pt
Vu at provided provided
τc τv τc max Check Stirrup Spacing Mini
Shear legs 0.75*d 300 Spacing
SL NO support at at Dia Of stirrup Spacing
KN support support N/mm
2
N/mm2 N/mm2 for τc mm
(Nos)
mm mm
mm mm Provided mm
mm2 mm2
1 33.019 400 0.38 0.43 0.31 3.1 O.K 8 2 -- 394.33 347.00 300 300.00
DESIGN CALCULATIONS FOR GUARD ROOM - SV1 STATION AT BODI GHODI Page 20 of 34
MAYTAS NAFTOGASBUD JV GSPL203-73-1506
Rev 1
Fy
Fz
Foundation Dimension:
Fx
Base Lx (m) 1.50 FGLx h1 (m)= 0.00
Lz (m) 1.50
Pedestal Px (m) 0.30 h2 (m)= 2.00
Pz (m) 0.30
D (m)= 0.35
Design Summary:
2
Max Bearing Press.: 179.34 KN/m
2
Mz1
Min Bearing Press.: 92.19 KN/m
Min Contact Length: 100%
X-Axis
Mx1
Material Properties:
Minimum 28 Days Compressive of Concrete : FC 25000 KN/m2
Yield Strength of Reinforcing Steel : FY 415000 KN/m2
Density of Structural fill 16 KN/m3
Density of Concrete 25 KN/m3
Load Combination:
Unfactored Loads (in KN m)
LC No. Fx Fy Fz Mx Mz
Case I (DL+LL) 16/46 2.82 83.00 1.35 0.89 1.87
Case II (DL+LL+WL) 16/80 2.82 100.78 7.92 8.67 1.87
Case III (DL+LL+EQ-Z) 16/60 2.819 118.027 13.4 15.043 1.873
LC No. Fx Fy Fz Mx Mz
Case I (DL+LL) 16/46 4.23 124.50 2.02 1.34 2.81
Case II (DL+LL+WL) 16/80 4.23 151.17 11.89 13.01 2.81
Case III (DL+LL+EQ-Z) 16/60 4.23 177.04 20.10 22.56 2.81
DESIGN CALCULATIONS FOR GUARD ROOM - SV1 STATION AT BODI GHODI Page 21 of 34
MAYTAS NAFTOGASBUD JV GSPL203-73-1506
Rev 1
ex / Lx = 0.031 From Table, K= 1.26 (From Handbook of concrete by Mark Fintel page 147 Fig 5-16)
ez / Lz = 0.015 Max. Bearing Press.=qmax =K x P / Lx * Lz = 92.19 KN/m2 < q all = q safe + γ x h2
=> Hence Satisfactory
Case II:
Axial load P = Fy + SubStructure Load = 181.9 KN
Moment at base Mx1= Mx + Fz x (h1+h2) = 24.52 KNm
Moment at base Mz1= Mz + Fx x (h1+h2) = 7.51 KNm
Eccentricity,
ex = Mz1 / P = 0.041 m < Lx / 6 Contact Length= 3 x (Lx /2 - ex) / Lx = 100%
ez = Mx1 / P = 0.135 m < Lz / 6 Contact Length= 3 x (Lz /2 - ez) / Lz = 100%
ex / Lx = 0.028 From Table, K= 1.69 (From Handbook of concrete by Mark Fintel page 147 Fig 5-16)
ez / Lz = 0.090 Max. Bearing Press.=qmax =K x P / Lx * Lz = 136.39 KN/m2 < q all =1.25* q safe + γ x h2
=> Hence Satisfactory
Case III:
Axial load P = Fy + SubStructure Load = 199.2 KN
Moment at base Mx1= Mx + Fz x (h1+h2) = 41.843 KNm
Moment at base Mz1= Mz + Fx x (h1+h2) = 7.51 KNm
Eccentricity,
ex = Mz1 / P = 0.038 m < Lx / 6 Contact Length= 3 x (Lx /2 - ex) / Lx = 100%
ez = Mx1 / P = 0.210 m < Lz / 6 Contact Length= 3 x (Lz /2 - ez) / Lz = 100%
ex / Lx = 0.025 From Table, K= 2.03 (From Handbook of concrete by Mark Fintel page 147 Fig 5-16)
ez / Lz = 0.140 Max. Bearing Press.=qmax =K x P / Lx * Lz = 179.34 KN/m2 < q all = 1.25*q safe + γ x h2
=> Hence Satisfactory
DESIGN CALCULATIONS FOR GUARD ROOM - SV1 STATION AT BODI GHODI Page 22 of 34
MAYTAS NAFTOGASBUD JV GSPL203-73-1506
Rev 1
DESIGN CALCULATIONS FOR GUARD ROOM - SV1 STATION AT BODI GHODI Page 23 of 34
MAYTAS NAFTOGASBUD JV GSPL203-73-1506
Rev 1
Bottom Reinforcement:
X-Direction:
Maximum Moment Mx = 32.70 KNm / Unit Width
2
q n = Mu/bd =
Required 0.42 N/Sqmm.
ρ =
2
0.00121 Ast = ρ x b x d = 336.4 mm Providing Bar : # 12
ρmin =
2
0.0012 Ast (min) = 334.8 mm Spacing Required = 336.18 mm
ρ =
2
0.00121 Ast = ρ x b x d = 336.4 mm Providing Bar : # 12
ρmin =
2
0.0012 Ast (min) = 334.8 mm Spacing Required = 336.18 mm
Top Reinforcement:
Maximum fws = 51.62 KN/m2
BM in X - Direction = (fws x ax2/2) = 9.29 KNm
2
BM in Z - Direction = (fws x a z /2) = 9.29 KNm
X-Direction:
Maximum Moment Mx = 9.29 KNm / Unit Width
2
q n = Mu/bd =
Required 0.12 N/Sqmm.
ρ =
2
0.00035 Ast = ρ x b x d = 97.8 mm Providing Bar : # 10
ρmin =
2
0.0012 Ast (min) = 334.8 mm Spacing Required = 234.56 mm
DESIGN CALCULATIONS FOR GUARD ROOM - SV1 STATION AT BODI GHODI Page 24 of 34
MAYTAS NAFTOGASBUD JV GSPL203-73-1506
Rev 1
Z-Direction:
Maximum Moment Mx = 9.29 KNm / Unit Width
2
q n = Mu/bd =
Required 0.12 N/Sqmm.
ρ =
2
0.00035 Ast = ρ x b x d = 97.8 mm Providing Bar : # 10
ρmin =
2
0.0012 Ast (min) = 334.8 mm Spacing Required = 234.56 mm
STABILITY CHECK
Overturning Check
Case 1
Overturning moment in' Z' direction= 7.5 KNm
Restoring moment in' Z' direction= 123.1 KNm
Factor of safety= 16.4 >1.5 Hence Satisfactory
Overturning moment in' X' direction= 3.6 KNm
Restoring moment in' X' direction= 123.1 KNm
Factor of safety= 34.3 >1.5 Hence Satisfactory
Case 2
Overturning moment in' Z' direction= 7.5 KNm
Restoring moment in' Z' direction= 136.4 KNm
Factor of safety= 18.2 >1.5 Hence Satisfactory
Overturning moment in' X' direction= 24.5 KNm
Restoring moment in' X' direction= 136.4 KNm
Factor of safety= 5.6 >1.5 Hence Satisfactory
Case 3
Overturning moment in' Z' direction= 7.5 KNm
Restoring moment in' Z' direction= 149.4 KNm
Factor of safety= 19.9 >1.5 Hence Satisfactory
Overturning moment in' X' direction= 41.8 KNm
Restoring moment in' X' direction= 149.4 KNm
Factor of safety= 3.6 >1.5 Hence Satisfactory
Sliding check
Coefficient of friction= 0.5
Case 1
Total sliding force= 3.1 KN
Resisting frictional force= 82.1 KN
Factor of safety= 26.3 >1.5 Hence Satisfactory
Case 2
Total sliding force= 8.4 KN
Resisting frictional force= 91.0 KN
Factor of safety= 10.8 >1.5 Hence Satisfactory
Case 3
Total sliding force= 8.4 KN
Resisting frictional force= 99.6 KN
Factor of safety= 11.8 >1.5 Hence Satisfactory
DESIGN CALCULATIONS FOR GUARD ROOM - SV1 STATION AT BODI GHODI Page 25 of 34
MAYTAS NAFTOGASBUD JV GSPL203-73-1506
Rev 1
============================================================================
C O L U M N N O. 14 D E S I G N R E S U L T S
DESIGN CALCULATIONS FOR GUARD ROOM - SV1 STATION AT BODI GHODI Page 26 of 34
MAYTAS NAFTOGASBUD JV GSPL203-73-1506
Rev 1
C O L U M N N O. 17 D E S I G N R E S U L T S
============================================================================
============================================================================
C O L U M N N O. 19 D E S I G N R E S U L T S
============================================================================
C O L U M N N O. 21 D E S I G N R E S U L T S
DESIGN CALCULATIONS FOR GUARD ROOM - SV1 STATION AT BODI GHODI Page 27 of 34
MAYTAS NAFTOGASBUD JV GSPL203-73-1506
Rev 1
STAAD SPACE -- PAGE NO. 102
============================================================================
C O L U M N N O. 22 D E S I G N R E S U L T S
============================================================================
============================================================================
C O L U M N N O. 23 D E S I G N R E S U L T S
DESIGN CALCULATIONS FOR GUARD ROOM - SV1 STATION AT BODI GHODI Page 28 of 34
MAYTAS NAFTOGASBUD JV GSPL203-73-1506
Rev 1
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 190 mm c/c
============================================================================
C O L U M N N O. 24 D E S I G N R E S U L T S
DESIGN CALCULATIONS FOR GUARD ROOM - SV1 STATION AT BODI GHODI Page 29 of 34
MAYTAS NAFTOGASBUD JV GSPL203-73-1506
Rev 1
DESIGN CALCULATIONS FOR GUARD ROOM - SV1 STATION AT BODI GHODI Page 30 of 34
MAYTAS NAFTOGASBUD JV GSPL203-73-1506
Rev 1
DESIGN CALCULATIONS FOR GUARD ROOM - SV1 STATION AT BODI GHODI Page 31 of 34
MAYTAS NAFTOGASBUD JV GSPL203-73-1506
Rev 1
DESIGN CALCULATIONS FOR GUARD ROOM - SV1 STATION AT BODI GHODI Page 32 of 34
MAYTAS NAFTOGASBUD JV GSPL203-73-1506
Rev 1
Plinth Beam
Max Support BM Mz/ Max Fy
Beam
Beam LC Section Fx(KN) Fy(KN) Fz(KN) Mx(KN.m) My(KN.m) Mz(KN.m) Marking
1 28 1 -0.99 -61.756 0 0 0 53.1
Max Mid span BM Mz PB1
1 12 0 -0.594 -1.739 0 0 0 -31.565
Max Support BM Mz/Max Fy
4 11 1 0.793 -60.987 0 0 0 44.754
Max Mid span BM Mz PB2
3 13 0 0.476 -19.323 0 0 0 -36.612
Roof Beam
Max Support BM Mz/ Max Fy
Beam LC Section Fx(KN) Fy(KN) Fz(KN) Mx(KN.m) My(KN.m) Mz(KN.m)
10 28 1 5.333 -36.189 0 4.415 0 31.244
Max Mid span BM Mz RB1
9 10 0.333 5.333 -2.49 0 1.472 0 -13.945
Max Support BM Mz/Max Fy
11 29 1 1.25 -33.019 0 3.065 0 25.942
Max Mid span BM Mz RB2
11 13 0 0.75 -8.332 0 -1.839 0 -16.378
DESIGN CALCULATIONS FOR GUARD ROOM - SV1 STATION AT BODI GHODI Page 33 of 34
MAYTAS NAFTOGASBUD JV GSPL203-73-1506
Rev 1
6.0 CONCLUSION
SIZE (IN MM) AT BOTTOM AT TOP
BEAMS
PLINTH BEAM 230 X500 2 #16 (TOP & Stirrups #8 @ 150 c/c
BOTTOM)
ROOF BEAM 230 X300 2#12 (TOP & Stirrups #8 @ 150 c/c
BOTTOM)
ROOF SLAB 120 TK. #8 @ 200 C/C (Main) #8 @ 200 C/C (Main)
#8 @ 200 C/C (Dist) #8 @ 200 C/C (Dist.)
DESIGN CALCULATIONS FOR GUARD ROOM - SV1 STATION AT BODI GHODI Page 34 of 34