Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Property Melt volume-flow rate Molding shrinkage parallel (p) normal (n) Symbol MVR SMP SMN Standard ISO 1133 ISO 294-4 (Th.-plast) ISO 2577 (Th.-sets) Specimen (Dimensions in mm) Material Unit Supplementary Instructions Test conditions
cm/10 min Test conditions according to the relevant material standard parallel to flow direction % normal to flow direction
60 * 60 * 2
Mechanical Properties
Tensile modulus Yield stress Yield strain Nominal strain at break Stress at 50% strain Stress at break Strain at break Stress at break (TPE) Strain at break (TPE) Stress at 10% strain Stress at 100% strain Stress at 300% strain Tensile creep modulus 1h 1000h unnotched Charpy impact strength notched acA-30 Et Y Y tB 50 B B B tB 10 100 300 Etc1 Etc10
3
1mm/min
% If Yield stress exists. MPa % MPa % If strain at break is greater than 300%: indicate'>300' If yield stress does not exist All strains <= 0.5%. All strains <= 0.5%. If Yield stress does not exist.
50mm/min
If Yield stress and Stress at If Strain break <= 10%, 5mm/min If 10% < Strain at break <= 50%, 50 % strain don't exist. 50mm/min
ISO 527-1/1BA
MPa
ISO 899-1
MPa
+23C Using conventional impact pendulums and respecting their individual application ranges, that -30C with the largest value of its potential energy possible shall be selected, see ISO 179 (Charpy), 8256 +23C (tensile impact) and 13802 (pendulums). For instrumented Charpy tests see ISO 179-2 Notched: Reliable if Charpy impact strength shows -30C "NB".
13
Property Tensile impact strength Puncture impact properties Max. Force Punct. Energy Compression set under constant strain 23C
Unit
Supplementary Instructions
ISO 6603-2
Up to the deflection at which the force has dropped down to half the maximum force. Specimens may be stacked if initial thickness is smaller than 6.3 mm. Time of measurement after relief of compression 30 min ISO 815 refers to IRHD in order to define the strain to be applied.
ISO 815
23C, 25% strain, 22 -24 h 70C, 25% strain, 22 -24 h 100C, 25% strain, 22 -24 h
70C
CS70 %
IRHD 10 - 95 80 - 89 90 - 95 >95
100C
CS100
Determination of IRHD acc. ISO 48 Tear strength TearS ISO 34-1 angle test specimen with nick kN/m Method B, prcedure b. Loading in parallel direction, the cut (nick ) is in the normal direction 500 mm/min
Footnotes: (*) e: Edge wise blow according to ISO 179: 1993 (**) u: unnotched (***) This bar may be taken from the central region of the multi- purpose- test specimen according to ISO 3167
14
Electrical Properties
Property Relative permittivity Dissipation factor 100 Hz 1 MHz 100 Hz 1 MHz Symbol r100 r1M tan100 tan1M e IEC 60093 60 * 60 * 2 Plaque with thickness: 1.0mm +/- 0.1mm(*) m Use contact electrodes voltage 500V. Use contact electrodes voltage 500V. Use contacting line electrodes, 50 mm long and with a gap of 5 mm, and a grounded contacting electrode at the back side of the plate. Short- time test, voltagerate 2kV/s Immersion in transformer oil according to IEC 60296. Test liquid A ISO 60250 60 * 60 * 2 E-4 Standard Specimen (Dimensions in mm) Unit Supplementary Instructions Test conditions 100 Hz 1 MHz 100 Hz 1 MHz
Volume resistivity
Surface resistivity
EB1 Electric strength Comparative tracking index CTI IEC 60243-1 IEC 60112 15 * 15 * 4 kV/mm -
Thermal Properties
Melting temperature Glass transition temperature Temperature of deflection under load (flexural softening temperature) Vicat softening temperature Coefficient of linear thermal expansion Parallel (p) Normal (n) Tm Tg ISO 11357-1 and -3 ISO 11357-1 and -2 C Tf1,8 Tf0,45 Tf8,0 TV50/50 p ISO 11359-1 and -2 n (**) 10 . C
-4 -1
Material
C 1 b)(DSC or DTA) Method A (DSC or DTA) Only for amorphous, single-phase thermoplastics. For both rigid and less rigid materials For rigid materials only
10C/min
50C/h; 50N 23 C - 55 C, Normal to the flow direction 23 C - 55 C, Parallel to the flow direction
15
Property Burning behavior 1.5 mm thick -.- mm thick Flammability by oxygen index
Standard
Specimen (Dimensions in mm) 125 * 13 * 1.5 150 * 150 * 1.5 125 * 13 * -.150 * 150 * -.80 * 10 * 4
Unit
Supplementary Instructions Indicate class from the following sequence B50:HB, V-2, V-1, V-0 B500: N, 5VA or 5VB Method A
Test conditions
UL 94
Class
Footnotes: (*) This bar may be taken from the central region of the multi- purpose- test specimen according to ISO 3167. Test specimen 80 mm x10 mm x 4 mm 110 mm x 10mm x 4 mm Loading direction flatwise edgewise Span 64 mm 100mm
(**) can be taken from the central region of the multipurpose - test specimen according to ISO 3167
Electrical Properties
Relative permittivity Dissipation factor Volume resistivity Surface resistivity 100 Hz 1 MHz 100 Hz 1 MHz r100 r1M tan100 tan1M e e IEC 60093 IEC 60250 60 * 60 * 2 10 10
-4 -4
Use contact electrodes voltage 500V Use contact electrodes voltage 500V. Use contacting line electrodes, 50 mm long and with a gap of 5 mm, and a grounded contacting electrode at the back side of the plate Short- time test, voltagerate 2kV/s Immersion in transformer oil according to IEC 60296. Test liquid A
Electric strength
EB1
IEC 60243-1
60 * 60 * 1
kV/mm
CTI
IEC 60112
15 * 15 * 4
16
Other Properties
Property Water absorption Humidity absorption Density Symbol WW WH ISO 1183 10 * 10 * 4 (*) kg/m
3
Unit %
Supplementary Instructions
Test conditions
Saturation values
(*) can be taken from the central region of the multipurpose - test specimen according to ISO 3167
17
g/(m*d)
18