Minimum Edge Distance
The distance from the center of a standard hole to an edge of a connected part shall be not less than the applicable value from the table below.

Information
Angle Conversion Calculator Edge Distance Holes and Slots Measures of Angle Shape Tables Software
1

Minimum Edge Distance, in. (Center of Standard Holea to Edge of Connected Part)
Nominal Bolt Diameter (in.) 1/2 5/8 3/4 7/8 At Sheared Edges 7/8 1 1/8 1 1/4 1 1/2c 1 3/4c 2 2 1/4 1 3/4 x Dia.
a For oversized or slotted holes, see the table below. b All edge distances in this column may be reduced 1/8-in. when the hole is at a point where stress does not

At Rolled Edges of Plates, Shapes or Bars Gas Cut or Saw-cut Edges b 3/4 7/8 1 1 1/8 1 1/4 1 1/2 1 5/8 1 1/4 x Dia.

Structural Steel Materials Surface Preparation Videos Weld Symbols

1 1/8 1 1/4 Over 1 1/4

exceed 25% of the maximum design strength in the element.


c These may be 1 1/4 in. at the ends of beam connection angles.

Files
AutoCad Catalogs Educational

Anchor Bolt Holes


Hole sizes for steel-to-steel structural connections are not the same as hole sizes for steel-to-concrete anchorage applications. In the case of steel-to-steel connections, the parts are made in a shop under good quality control, so standard holes (bolt diameter plus 1/16"), oversized holes (bolt diameter plus 3/16"), and short and long-slotted holes can be used quite successfully. However, the field placement of anchorage devices has long been subject to more permissive tolerances (and often, inaccuracies that exceed those tolerances anyway and may require consideration by the structural Engineer of Record). AISC published Steel Design Guide Series 1, Column Base Plates back in the early 1990s. At that time, it was recognized that the quality of foundation work was getting worse and worse. To allow the erector (and designer) greater latitude when possible, the permissible hole sizes in base plates were increased. These same larger hole sizes were included in the 2nd ed. LRFD Manual. The values there are maximums, not a required size. Smaller holes can be used if desired. Plate washers are generally required with these holes because ASTM F436 washers can collapse into the larger-sized holes, even under erection loads. The larger hole sizes are primarily intended for the majority of base plates that transfer only axial compression from the column into the foundation. The anchor rods don't usually do much after erection in that case. To allow for misplaced bolts, holes in base plates are oversized. The AISC Manual of Steel Construction recommends the following oversized hole diameters for each bolt diameter:

Links
American Institute of Steel Construction American Iron and Steel Institute American Welding Society Hilti Modern Steel Construction Steel Deck Institute Steel Joist Institute Vulcraft

Anchor Bolt Hole Dimensions

http://www.structuralsteeldetailer.us/edge_distance.html[2011-03-08 11:01:11]

Edge Distance

Wagner - Braun Jobber Instruments Calculated Industries Alcott Slide Charts

Bolt Diameter 3/4 7/8 1 1 1/4 1 1/2

Hole Size 1 5/16 1 9/16 1 13/16 2 1/16 2 5/16 2 3/4 3 1/4 3 3/4

Books

1 3/4 2 2 1/2

Manual of Steel Construction Am Institute of St...

AISC, Steel Design Guide Series 1, Column Base Plates, suggests that using oversize holes meeting these criteria may still not accommodate field variations in anchor bolt placement and suggests adding 1/4 in. to the hole diameter listed. The guide recommends using a heavy plate washer over the holes. The AISC Structural Steel Educational Council cites the following example: "If bolts are misplaced up to 1/2 inch, the oversized base plate holes normally allow the base plate and column to be placed near or on the column line. If the bolts are misplaced by more than 1/2 inch, then corrective work is required." Based on AISC oversize holes, the AISC Structural Steel Educational Council recommendations, and concrete contractor anchor-bolt placement techniques, ASCC (American Society of Concrete Contractors) concrete contractors recommend the following tolerance for each bolt location: 3/4-in. and 7/8-in. diameter bolts: 1/4 in. 1-in., 1-1/4-in., and 1-1/2-in. diameter bolts: 3/8 in. 1-3/4-in., 2-in., and 2-1/2-in. diameter bolts: 1/2 in.

AISC Seismic Design Manual, 2006 American Institute...

Manual of Steel Construction Load an... AISC Manual Commit...

AISC Manual of Steel Construction Aisc Manual Commit...

LRFD Steel Design William T.(William... New $201.95 Load & Resistance Factor Design American Institute...

Privacy Information

structuralsteeldetailer.us | Last Modified: 2008-11-07

http://www.structuralsteeldetailer.us/edge_distance.html[2011-03-08 11:01:11]

Potrebbero piacerti anche