Edge Distance
Minimum Edge Distance
The distance from the center of a standard hole to an edge of a connected part shall be not less than the applicable value from the table below.
Information
Angle Conversion Calculator Edge Distance Holes and Slots Measures of Angle Shape Tables Software
1
Minimum Edge Distance, in. (Center of Standard Holea to Edge of Connected Part)
Nominal Bolt Diameter (in.) 1/2 5/8 3/4 7/8 At Sheared Edges 7/8 1 1/8 1 1/4 1 1/2c 1 3/4c 2 2 1/4 1 3/4 x Dia.
a For oversized or slotted holes, see the table below. b All edge distances in this column may be reduced 1/8-in. when the hole is at a point where stress does not
At Rolled Edges of Plates, Shapes or Bars Gas Cut or Saw-cut Edges b 3/4 7/8 1 1 1/8 1 1/4 1 1/2 1 5/8 1 1/4 x Dia.
Files
AutoCad Catalogs Educational
Links
American Institute of Steel Construction American Iron and Steel Institute American Welding Society Hilti Modern Steel Construction Steel Deck Institute Steel Joist Institute Vulcraft
http://www.structuralsteeldetailer.us/edge_distance.html[2011-03-08 11:01:11]
Edge Distance
Hole Size 1 5/16 1 9/16 1 13/16 2 1/16 2 5/16 2 3/4 3 1/4 3 3/4
Books
1 3/4 2 2 1/2
AISC, Steel Design Guide Series 1, Column Base Plates, suggests that using oversize holes meeting these criteria may still not accommodate field variations in anchor bolt placement and suggests adding 1/4 in. to the hole diameter listed. The guide recommends using a heavy plate washer over the holes. The AISC Structural Steel Educational Council cites the following example: "If bolts are misplaced up to 1/2 inch, the oversized base plate holes normally allow the base plate and column to be placed near or on the column line. If the bolts are misplaced by more than 1/2 inch, then corrective work is required." Based on AISC oversize holes, the AISC Structural Steel Educational Council recommendations, and concrete contractor anchor-bolt placement techniques, ASCC (American Society of Concrete Contractors) concrete contractors recommend the following tolerance for each bolt location: 3/4-in. and 7/8-in. diameter bolts: 1/4 in. 1-in., 1-1/4-in., and 1-1/2-in. diameter bolts: 3/8 in. 1-3/4-in., 2-in., and 2-1/2-in. diameter bolts: 1/2 in.
LRFD Steel Design William T.(William... New $201.95 Load & Resistance Factor Design American Institute...