Sei sulla pagina 1di 308

Engineering Department

E/A Design Division CAD Standard

LAST UPDATED MARCH 2010

Engineering Department Manual


E/A Design Division CAD Standard TOC

TABLE OF CONTENTS

6.0

E/A Design Division CAD Standard


6.1 6.2 6.3 6.4 Foreword Purpose
About this Standard 6.2.1 6.4.1 6.4.2 6.4.3 6.4.4 6.4.5 6.5.1 6.5.2 6.5.3 6.5.4 6.5.5 6.5.6 6.6.1 6.6.2 6.6.3 6.6.4 6.6.5 6.6.6 6.6.7 6.6.8 6.6.9 6.7.1 6.7.2 6.7.3 6.7.4 6.7.5 6.7.6 6.7.7 6.7.8 6.7.9 6.7.10 6.7.11 6.8.1 6.8.2 6.8.3 6.8.4

1
1 1
1

Acronyms and Abbreviations Digital Submittal Requirements


CAD File Formats Schedule Media and Format Identification Project Websites

3 3 3 4 4

2 3

6.5

Accessing the E/A Design Division CAD Standard


Using The Standard Files Distribution Files AutoDesk AutoCAD Architecture and AutoDesk AutoCAD MEP AutoDesk Land Desktop Companion AutoDesk Civil 3D AutoDesk Revit

5 5 9 10 11 11 12 13 13 18 18 21 23 24 25 25 26 26 27 27 28 30 30 31 31 31 33 33 34 34 35 36 36 38 44

6.6

Project Directory Structure and File Naming Convention


Project Directory Structure Project Identifier Number Discipline Folders Sample Project File Naming Convention Plotsheet Files DWF Files Drawing Number Convention Folder Naming Convention

12

6.7

CAD Practices and Procedures


Coordinate Systems Layering Scheme Definition Entity and Layer Linetypes Entity and Layer Colors Symbology Plotted Lineweights Text Styles and Heights Dimension and Leader Styles Table Styles External Reference Files Submissions AutoCAD 2010 Configuration (Plotting by Layout) Template Drawing Setup Units Page Setups

25

6.8

CAD Environment Setup

33

6.9 6.10 6.11 6.12

Plot Setup Stage I CAD Standard Plan Set Preparation Special Projects

6.10.1 Stage I Project Directory Structure 6.10.2 Stage I External Reference Files 6.11.1 Plan Set Title Sheet 6.11.2 Plan Set Plot Sheets 6.12.1 Confidential and Privileged Projects

34 35 36 44

Last Updated: March 2010

Page ii

Engineering Department Manual


E/A Design Division CAD Standard TOC 6.13 CAD Standards Review Report 45

6.13.1 Interim CAD Review 6.13.2 Construction Contract PA Wide CAD Review 6.13.3 Work Order CAD Review

45 45 45

6.14 6.15 6.16 6.17

Update and Revision Procedures Contact and Support Information Conclusion Appendix A Architectural Discipline
Content Preferences Layer Stratagem Linetypes Symbols Content Preferences Layer Stratagem Linetypes Symbols Civil 3D Content Preferences Layer Stratagem Linetypes Symbols Content Preferences Layer Stratagem Linetypes Symbols Content Preferences Layer Stratagem Linetypes Symbols Content Preferences Layer Stratagem Linetypes Symbols Content Preferences Layer Stratagem Linetypes Symbols Content Preferences Layer Stratagem Linetypes Symbols

6.17.1 6.17.2 6.17.3 6.17.4 6.18.1 6.18.2 6.18.3 6.18.4 6.18.5 6.19.1 6.19.2 6.19.3 6.19.4 6.20.1 6.20.2 6.20.3 6.20.4 6.21.1 6.21.2 6.21.3 6.21.4 6.22.1 6.22.2 6.22.3 6.22.4 6.23.1 6.23.2 6.23.3 6.23.4 6.24.1 6.24.2 6.24.3 6.24.4

50 51 70 72 86 87 95 96 99

49 49 49 50

6.18

Appendix B Civil Discipline

86

6.19

Appendix C Electrical Discipline

100 101 108 109 143 144 150 151 153 154 157 158 161 162 191 192 225 226 240 241 243 244 253 254 282 283 284 285 286 287 288

100

6.20

Appendix D Environmental Discipline

143

6.21

Appendix E Geotechnical Discipline

153

6.22

Appendix F Mechanical Discipline

161

6.23

Appendix G Structural Discipline

225

6.24

Appendix H Traffic Discipline

243

6.25 6.26

Appendix I Common Symbology Appendix J Contract Borders and Title Sheets


Title Sheet Title Sheet Oversized (OS) Title Sheet PATH Title Sheet PATH Oversized (OS) Contract Border

6.25.1 Graphic Scale Bars 6.25.2 North Arrows 6.26.1 6.26.2 6.26.3 6.26.4 6.26.5

282

284

Last Updated: March 2010

Page iii

Engineering Department Manual


E/A Design Division CAD Standard TOC
6.26.6 Contract Border Oversized (OS) 6.26.7 Contract Border PATH 6.26.8 Contract Border PATH Oversized (OS) 289 290 291 292 293 295 296 298 300 302 304

6.27

Appendix K Using Standard Forms on EOL (Internal Use Only)


PID Search Request Project Archival Request Project CAD Drawings Request Mandatory CAD Standards Review Request Non-Mandatory CAD Standards Review Request Work Order CAD Review Request Project Folder Structure

6.27.1 6.27.2 6.27.3 6.27.4 6.27.5 6.27.6 6.27.7

292

6.28 6.29

Appendix L Request to Change Standard CAD Standard Updates And Revisions

6.29.1 2010 Q1

303 304

Last Updated: March 2010

Page iv

Engineering Department Manual


E/A Design Division CAD Standard

6.0
6.1

E/A DESIGN DIVISION CAD STANDARD


FOREWORD

The EAD CAD Standard outlined within this document was established to provide guidance for the preparation of the Engineering / Architecture (E/A) Design Division of the Port Authority of New York and New Jerseys (PANYNJ) contract documents. This document is intended for use by both in-house personnel as well as outside consultants involved in creating or updating PANYNJ facilities Computer Aided Drafting (CAD) data.

6.2

PURPOSE

This Standard establishes requirements and procedures for the preparation and submission of CAD based drawings throughout the project life cycle. Adherence to this standard insures that the E/A Design Division of the PANYNJ will receive and produce data in a consistent format. This consistency will improve the compatibility of this data within each discipline and the efficient exchange of data between disciplines. The role of an individual assigned to the project determines the level of understanding required of the EAD CAD Standard. For CAD operators, designers, and functional supervisors a thorough knowledge of all CAD related elements associated with a project is crucial. The project manager however only requires a general knowledge of the EAD CAD Standard and the means by which it is employed to create a project. Both levels of knowledge will be possible through the use of this manual. The CAD system adopted by the PANYNJ is comprised of several Autodesk products. Throughout this manual terminology and references will be made that are unique to Autodesk and primarily, different AutoCAD based software applications. 6.2.1 ABOUT THIS STANDARD

The chapters within this standard describe how the E/A Design Division uses AutoCAD and how to configure AutoCAD to support the E/A Design Division CAD Standard, which it has adopted. The appendices, which follow, support the chapters in several ways. Each discipline has been assigned an appendix to explain information specific to their functional group. In addition, appendices have been provided to support CAD related subject matter, which is common throughout all disciplines. Finally, some appendices have been created to support internal E/A Design Division staff only; these appendices will be for internal use; however, they have been supplied with the document for both in-house and consultant staff.

Last Updated: 3/21/2010

Page 1

Engineering Department Manual


E/A Design Division CAD Standard

6.3

ACRONYMS AND ABBREVIATIONS


Acronym ACA APJ C3D CP CTB DST DWF DWG DWT EAD EOL FAC L:\ M:\ MEP N:\ PANYNJ PC3 PDF PID PMP RVT Definition AutoDesk AutoCAD Architecture Autodesk Project File AutoDesk Civil 3D Confidential and Privileged Color Dependant Plot Style Table Sheet Set Data File Design Web Format file AutoCAD drawing file AutoCAD template file Engineering Architecture Design Engineering on Line Facility Code Internally Mapped Network Drive pointing to \\Gatecsrv\Cad\Cadstd Internally Mapped Network Drive pointing to \\Gatecsrv\Cad\Cad AutoDesk AutoCAD MEP Internally Mapped Network Drive pointing to \\Gatecsrv\Cad\Archive Port Authority of New York and New Jersey Plotter Configuration file Portable Document Format file Project Identifier Number Plotter Model Parameter file AutoDesk Revit

The following are Acronyms and Abbreviations used throughout this document.

Last Updated: 3/21/2010

Page 2

Engineering Department Manual


E/A Design Division CAD Standard

6.4

DIGITAL SUBMITTAL REQUIREMENTS

The EAD CAD Standard adopts AutoCAD as the Standard CAD Software. Consultants are required to submit electronic CAD files in a format compatible with the current version of AutoCAD software in use by the E/A Design Division of the PANYNJ. In addition, all submitted files must conform and comply with the latest version of the EAD CAD Standard outlined in this document. Softcopy submittals (electronic CAD files) must include all information presented on the hardcopy submittals (plots). This precludes the use of sticky-backs, graphic tapes, hand lettering and anything else that is placed on the drawing after it is plotted excepting any signatures and seals. Consultants are required to submit CAD files accompanied with hardcopies every time a project reaches a submittal milestone. This includes, but is not limited to, PA Review Set, Law Review Set, Percent Submittal Set, Addendum Set, As Bid Set, PACC Set, Drawing of Record Set, etc. Refer to Section 6.7.10 titled Submissions for more information. 6.4.1 CAD FILE FORMATS

All electronic CAD files should be AutoCAD DWG files with binary compatibility with the current release of AutoCAD in use by the PANYNJ. When submitting files on electronic media, the AutoCAD drawing file version should be noted. If terrain model files are requested for the project, the consultant will submit these files in either Autodesk Land Desktop Digital Terrain Model format or XML format. If alignment files are requested for the project, the consultant will submit alignment files in either Autodesk Land Desktop Alignment format or XML format. If a coordinate geometry point database is requested for a project, the consultant will supply this database as either an Autodesk Land Desktop Point Database file (.mdb) or an XML file. When requested, these files will be submitted with the Autodesk Land Desktop project structure intact, as outlined in Section 6.5.4 titled AutoDesk Land Desktop Companion. If working on a Project using either AutoCAD Architecture (formerly Architectural Desktop - ADT) or AutoCAD MEP (formerly Building Systems - ABS), the consultant will submit the Project file (.apj) and the Sheet Set Data file (.dst). 6.4.2 SCHEDULE

DWG and DWF files are required for each milestone during both stage II and stage III. If the project does not have a milestone scheduled prior to the PA Wide Review submittal, DWG and DWF files will be submitted no later than 3 week prior to the PA Wide Review submittal. 6.4.3 MEDIA AND FORMAT

AutoCAD drawing files will be submitted on media CDs. All disks are to be delivered virus free. Final hard copies of drawings will be submitted as Mylar plots using the PANYNJ Contract Border identified in this standard.

Last Updated: 3/21/2010

Page 3

Engineering Department Manual


E/A Design Division CAD Standard 6.4.4 IDENTIFICATION

All CDs submitted to the E/A Design Division of the PANYNJ will be labeled with the following information: Consultants name and Project Identifier Number (PID) Contact name and phone number of consulting project manager Discipline-Facility (e.g. Civil-JFK) Submittal Date and Percent Completed Data Format (e.g. AutoCAD Version .dwg) File Name(s) on CD As much information as possible should be printed on both the CD label and the CD case. If all the information will not fit on either the CD label or the CD case, the information can be listed in an orderly manner in a text file that will be copied to the CD in electronic format. 6.4.5 PROJECT WEBSITES

The PANYNJ is in the process of developing a Project Extranet to enhance collaboration between inhouse designers and outside consultants, as well as with different departments and divisions throughout the agency. All Project Websites have a folder structure similar to that described in Section 6.6 titled Project Directory Structure and File Naming Convention of this standard. Please refer to the project specifics to determine if a Project Website is available for use. If so, all transfer of digital information should be made via the website. Transfer of data via email or CDs is not permitted if a project website is available. If a Project Website is available for the project the Project Website link will be provided along with a Username and a Password.

Last Updated: 3/21/2010

Page 4

Engineering Department Manual


E/A Design Division CAD Standard

6.5

ACCESSING THE E/A DESIGN DIVISION CAD STANDARD

The E/A Design Division CAD Standard includes a series of support files. All support files are provided in a folder named EAD_Standards, which is located on the root level of the L:\ drive of the PANYNJ network.

The EAD_Standards folder contains one general All Disciplines sub-folder and eight discipline specific sub-folders as illustrated in Figure 6-A.

Figure 6-A The All Disciplines sub-folder contains all cross discipline support files, including contract borders, stamps, fonts, layer key styles, page setups, plot stamps, plot styles, a sample project structure, support files, symbols and templates. The folder structure is illustrated in Figure 6-B.

Figure 6-B Each Discipline sub-folder is divided into four sub-folders which contain all the discipline specific support files including layer drawings, tool palettes, plotter files and tool palettes. An example of this folder structure is illustrated in Figure 6-C. The layer and symbol content within these folders can be accessed through the use of AutoCADs Design Center utility. Graphic depictions of the symbols for each discipline can be referenced in the appendices. Figure 6-C 6.5.1 USING THE STANDARD FILES

The EAD_Standards directory contains two primary types of files: files that do not require ongoing user interaction and files that do. The first type refers to support files accessed automatically by AutoCAD once they have been copied to the proper support folders. All E/A Design Division workstations have already been configured to access these files. Outside consultants should copy these files to the appropriate directories or create an AutoCAD profile pointing to the files as necessary. The second type refers to files such as title sheets, contract borders, drawing information blocks and stamps, which the user must configure within the project. For instructions on creating a title sheet or working with the contract borders, refer to Section 6.11 titled Plan Set Preparation. 6.5.2 DISTRIBUTION FILES Page 5

Last Updated: 3/21/2010

Engineering Department Manual


E/A Design Division CAD Standard This section identifies the files supplied for general use within the E/A Design Division CAD Standard. The entire E/A Design Division CAD Standard can be found internally at L:\EAD_Standards or externally downloaded from: http://www.panynj-cadstandards.com/
L:\EAD_Standards\
Contains the EAD_CAD_Standard and Request to Change Standard documents. All_Disciplines <Discipline> Contains all cross discipline support files and content. Contains all discipline specific support files and content.

L:\EAD_Standards\All_Disciplines\Contract Borders\ Border - ANSI A - Horizontal.dwg Border - ANSI A - Vertical.dwg Border - ANSI B - Horizontal.dwg Border - ANSI B - Vertical.dwg Contract_Border - OS.dwg Contract_Border_PATH - OS.dwg Contract_Border_PATH.dwg Contract_Border.dwg Drawing_Info - OS.dwg Drawing_Info.dwg Title_Sheet - OS.dwg Title_Sheet - PATH - OS.dwg Title_Sheet - PATH.dwg Title_Sheet.dwg 8.5x11 landscape border for use in non-contract drawings. 8.5x11 portrait border for use in non-contract drawings. 11x17 landscape border for use in non-contract drawings. 11x17 portrait border for use in non-contract drawings. 34x56 border for contract drawings. 34x56 border for Port Authority Trans Hudson contract drawings. 22x34 border for Port Authority Trans Hudson contract drawings. 22x34 border for contract drawings. Drawing information block for use with 34x56 borders. Drawing information block for use with 22x34 borders. 34x56 title sheet for contract drawings. 34x56 title sheet for Port Authority Trans Hudson contract drawings. 22x34 title sheet for Port Authority Trans Hudson contract drawings. 22x34 title sheet for contract drawings.

L:\EAD_Standards\All_Disciplines\Contract Borders\Stamps\ Contract_Border Stamp_Law-Review.dwg Contract_Border Stamp_Law-Review - OS.dwg Contract_Border Stamp_Preliminary.dwg Contract_Border Stamp_Preliminary - OS.dwg Contract_Border Stamp_QA-Submission.dwg Contract_Border Stamp_QA-Submission - OS.dwg Contract_Border Stamp_Submission.dwg Contract_Border Stamp_Submission - OS.dwg Drawing_Info - Stamp_CPbar.dwg Drawing_Info Stamp_CPbar OS.dwg Drawing_Info Stamp_NJ&NY PE (one consultant) - OS.dwg Drawing_Info - Stamp_NJ&NY PE (one consultant).dwg Drawing_Info - Stamp_NJ&NY PE (two consultants) - OS.dwg Drawing_Info - Stamp_NJ&NY PE (two consultants).dwg Law Review submission stamp for use on 22x34 borders. Law Review submission stamp for use on 34x56 borders. Preliminary submission stamp for use on 22x34 borders. Preliminary submission stamp for use on 34x56 borders. Quality Assurance submission stamp for use on 22x34 borders for FTA projects. Quality Assurance submission stamp for use on 34x56 borders for FTA projects. Percent submission stamp for use on 22x34 borders. Percent submission stamp for use on 34x56 borders. Confidential and Privileged stamp for use on 22x34 borders for CP drawings. Confidential and Privileged stamp for use on 34x56 borders for CP drawings. One consultant company providing NJ & NY PE signatures on 34x56 drawings. One consultant company providing NJ & NY PE signatures on 22x34 drawings. Two consultant companies providing NJ & NY PE signatures on 34x56 drawings. Two consultant companies providing NJ & NY PE signatures on 22x34 drawings.

Last Updated: 3/21/2010

Page 6

Engineering Department Manual


E/A Design Division CAD Standard
Drawing_Info - Stamp_NJ&NY RA (one consultant) - OS.dwg Drawing_Info - Stamp_NJ&NY RA (one consultant).dwg Drawing_Info - Stamp_NJ&NY RA (two consultants) - OS.dwg Drawing_Info - Stamp_NJ&NY RA (two consultants).dwg Drawing_Info Stamp_NJPE - OS.dwg Drawing_Info - Stamp_NJPE.dwg Drawing_Info Stamp_NJRA - OS.dwg Drawing_Info - Stamp_NJRA.dwg Drawing_Info - Stamp_NYPE - OS.dwg Drawing_Info - Stamp_NYPE.dwg Drawing_Info - Stamp_NYRA - OS.dwg Drawing_Info - Stamp_NYRA.dwg Drawing_Info - Stamp_Revision.dwg Drawing_Info - Stamp_Triangle.dwg L:\EAD_Standards\All_Disciplines\Fonts\ HELV-2F.SXH HELV-M.SHX Font used for Contract Border and Title Sheet information. Font used for Contract Border, Title Sheet & Alternate Title information. One consultant company providing NJ & NY RA signatures on 34x56 drawings. One consultant company providing NJ & NY RA signatures on 22x34 drawings. Two consultant companies providing NJ & NY RA signatures on 34x56 drawings. Two consultant companies providing NJ & NY RA signatures on 22x34 drawings. One consultant company providing NJ PE signatures on 34x56 drawings. One consultant company providing NJ PE signatures on 22x34 drawings. One consultant company providing NJ RA signatures on 34x56 drawings. One consultant company providing NJ RA signatures on 22x34 drawings. One consultant company providing NY PE signatures on 34x56 drawings. One consultant company providing NY PE signatures on 22x34 drawings. One consultant company providing NY RA signatures on 34x56 drawings. One consultant company providing NY RA signatures on 22x34 drawings. Revision stamp for use on both 22x34 and 34x56 drawings. Revision triangle marker for placement near revision clouds.

L:\EAD_Standards\All_Disciplines\Layer Key Styles\ PA_LKS-ACA2010 - Architectural.dwg PA_LKS-ACA2010 - Structurall.dwg PA_LKS-MEP2010 - Electrical.dwg PA_LKS-MEP2010 - Mechanical.dwg L:\EAD_Standards\All_Disciplines\Page Setups\ 115Bway.dwg Architectural.dwg Civil.dwg Electrical.dwg Environmental.dwg Geotechnical.dwg Mechanical.dwg Structural.dwg Traffic.dwg L:\EAD_Standards\All_Disciplines\Palettes\ Generic Tool Palettes for use by all disciplines. Drawing file containing pre-configured page setups for plotting drawings to devices located at 115 Broadway. Drawing file containing pre-configured page setups for plotting drawings to devices located within the Architectural Plotter Room at 2 Gateway. Drawing file containing pre-configured page setups for plotting drawings to devices located within the Civil Plotter Room at 2 Gateway. Drawing file containing pre-configured page setups for plotting drawings to devices located within the Electrical Plotter Room at 2 Gateway. Drawing file containing pre-configured page setups for plotting drawings to devices located within the Environmental Plotter Room at 2 Gateway. Drawing file containing pre-configured page setups for plotting drawings to devices located within the Geotechnical Plotter Room at 2 Gateway. Drawing file containing pre-configured page setups for plotting drawings to devices located within the Mechanical Plotter Room at 2 Gateway. Drawing file containing pre-configured page setups for plotting drawings to devices located within the Structural Plotter Room at 2 Gateway. Drawing file containing pre-configured page setups for plotting drawings to devices located within the Traffic Plotter Room at 2 Gateway. Layer Key Style for use by the Architectural Discipline within ACA Layer Key Style for use by the Structural Discipline within ACA Layer Key Style for use by the Electrical Discipline within MEP Layer Key Style for use by the Mechanical Discipline within MEP

Last Updated: 3/21/2010

Page 7

Engineering Department Manual


E/A Design Division CAD Standard
L:\EAD_Standards\All_Disciplines\Plot Stamps 11x17 horizontal.pss 11x17 vertical.pss 22x34 horizontal.pss 22x34 vertical.pss 34x56 horizontal.pss 34x56 vertical.pss L:\EAD_Standards\All_Disciplines\Plot Styles PA MasterColor.ctb PA MasterFull.ctb PA MasterHalf.ctb Plot Style for plotting Drawings in Color. Plot Style for plotting Full Scale Drawings. Plot Style for plotting Half Scale Drawings. Places Plot stamp Horizontally on the bottom edge of the 11x17 sheet. Places Plot stamp Vertically on the left edge of the 11x17 sheet. Places Plot stamp Horizontally on the bottom edge of the 22x34 sheet. Places Plot stamp Vertically on the left edge of the 22x34 sheet. Places Plot stamp Horizontally on the bottom edge of the 34x56 sheet. Places Plot stamp Vertically on the left edge of the 34x56 sheet.

L:\EAD_Standards\All_Disciplines\Sample Project Contains a Sample Folder Structure that mimics the Folder Structure used when new projects are created. L:\EAD_Standards\All_Disciplines\Support PA.shx PA - Design.lin L:\EAD_Standards\All_Disciplines\Symbols BS1-1_2in-1ft.dwg BS1_2in-1ft.dwg BS1_4in-1ft.dwg BS1_8in-1ft.dwg BS1_16in-1ft.dwg BS1_32in-1ft.dwg BS1in-1ft.dwg BS1in-1in.dwg BS1in-5ft.dwg BS1in-10ft.dwg BS1in-20ft.dwg BS1in-25ft.dwg BS1in-30ft.dwg BS1in-40ft.dwg BS1in-50ft.dwg BS1in-60ft.dwg BS1in-100ft.dwg BS1in-200ft.dwg BS1in-400ft.dwg BS1in-500ft.dwg BS3_4in-1ft.dwg BS3_8in-1ft.dwg BS3_16in-1ft.dwg BS3_32in-1ft.dwg BS3in-1ft.dwg BS6in-1ft.dwg 1 1/2 = 1 Bar Scale 1/2 = 1 Bar Scale 1/4 = 1 Bar Scale 1/8 = 1 Bar Scale 1/16 = 1 Bar Scale 1/32 = 1 Bar Scale 1 = 1 Bar Scale 1 = 1 Bar Scale 1 = 5 Bar Scale 1 = 10 Bar Scale 1 = 20 Bar Scale 1 = 25 Bar Scale 1 = 30 Bar Scale 1 = 40 Bar Scale 1 = 50 Bar Scale 1 = 60 Bar Scale 1 = 100 Bar Scale 1 = 200 Bar Scale 1 = 400 Bar Scale 1 = 500 Bar Scale 3/4 = 1 Bar Scale 3/8 = 1 Bar Scale 3/16 = 1 Bar Scale 3/32 = 1 Bar Scale 3 = 1 Bar Scale 6 = 1 Bar Scale Shape file used by certain line types. Line type definition file containing custom line types.

Last Updated: 3/21/2010

Page 8

Engineering Department Manual


E/A Design Division CAD Standard
N_ARROW1.dwg N_ARROW2.dwg L:\EAD_Standards\All_Disciplines\Templates PA 3d Solid Template.dwt PA ACA Model Template.dwt PA arch-units.dwt PA Civil-C3D.dwt PA deci-units.dwg PA Geotechnical-C3D.dwt PA MEP Model Template.dwt L:\EAD_Standards\<Discipline>\Layers Contains all Layer template files (.dwt) specific to that discipline. L:\EAD_Standards\<Discipline>\Palettes Contains all Tool Palette files (.atc) specific to that discipline. L:\EAD_Standards\<Discipline>\Plotters Contains all Plotter Configuration files (.pc3) specific to that discipline. L:\EAD_Standards\<Discipline>\Plotters\PMP Files Contains all Plotter Model Parameter files (.pmp) specific to that discipline. L:\EAD_Standards\<Discipline>\Symbols Contains all the symbol library files (.dwg) used by that discipline. Drawing Template for drawings using 3d Solids. Drawing Template for ACA Model file drawings. Drawing Template for Architectural Unit based drawings. Drawing Template for Civil Discipline based Civil 3D drawings. Drawing Template for Decimal Unit based drawings. Drawing Template for Geotechnical Discipline based Civil 3D drawings. Drawing Template for MEP Model file drawings. North Arrow within Bubble North Arrow

6.5.3

AUTODESK AUTOCAD ARCHITECTURE AND AUTODESK AUTOCAD MEP

The Project Navigator within ACA or MEP can only be used when AEC objects are used as part of the project. If the condition above is met, projects are to be created in the MODEL folder for the appropriate discipline. ACA and MEP will create and name a project folder automatically when the user sets up an ACA or an MEP project using the Project Navigator. The EAD CAD Standard requires that the user names the ACA and MEP project name after the PID Number. Once created, the project folder will contain at minimum the following 4 sub-folders: Constructs, Elements, Sheets and Views. In addition to the folders created an AutoDesk Project Information file (.apj) and a Sheet Set Data file (.dst) will be created. The .dst file is to be named after the PID Number as well. A sample project structure is shown in Figure 6-D. Files and folders created using Project Navigator are not to be edited, Figure 6-D moved or deleted by any means other than through Project Navigator. Using other means than the Project Navigator to edit or delete any project information will result in inconsistent project data.

Consultants are required to create their own Sheet Creation Template file and are responsible for matching the fields to the ones provided within the Contract Border and Drawing Information included with

Last Updated: 3/21/2010

Page 9

Engineering Department Manual


E/A Design Division CAD Standard this standard. To ensure the availability of the right display configurations, when using the Project Navigator all drawings are to be created based on one of the following templates: PA - ACA Model Template.dwt PA - MEP Model Template.dwt The above template files have been provided with this standard and can be found under: EAD_Standards\All Disciplines\Template\ The following Layer Key Styles have also been provided under EAD_Standards\All Disciplines\Layer Key Styles\: PA_LKS-ACA2010 - Architectural.dwt PA_LKS-ACA2010 - Structural.dwt PA_LKS-MEP2010 - Electrical.dwt PA_LKS-MEP2010 - Mechanical.dwt Due to the nature of the Project Navigator, files are attached automatically using the Attach and Overlay methods, therefore an exception to the required use of the Overlay method of attachment stated else ware in this standard will be made when Project Navigator is used. When the Project Navigator is used, the contents of the Constructs folder are to be copied into the owning disciplines PUBLISH folder so their backgrounds can be used by other disciplines. These files are to be provided without any external references attached. 6.5.4 AUTODESK LAND DESKTOP COMPANION

LDC project data will be stored in the Land Projects folder located on the L: drive of the PANYNJ network. Within the Land Projects folder are facility specific sub-folders. Within the facility folders are project specific sub-folders, each named using the Project Identifier Number (PID) for that particular project. LDC will create and name a PID folder automatically when the user sets up a Land Desktop Project. The EAD CAD Standard requires the user to name the LDC project after the PID, in order to ensure the folder is named correctly. Within the PID folder will be the standard LDC sub-folders containing project specific alignment files, digital terrain models, point database files, etc. Drawings should not be stored in any of these folders but should rather be stored according the directory described in Section 6.6 titled Project Directory Structure and File Naming Convention. A sample LDC project structure is shown in the image to the right. The entire LDC project structure will be archived and backed up with the project drawing information.

Figure 6-E

Last Updated: 3/21/2010

Page 10

Engineering Department Manual


E/A Design Division CAD Standard 6.5.5 AUTODESK CIVIL 3D

When using C3D, project drawings and data should be stored in the MODEL folder of the appropriate discipline. M:\<Facility Name>\<PID Number>\<Discipline>\Model\ For a more in depth breakdown on how to use C3D within the PANYNJ reference the Civil 3D Standard which is included within Section 6.18.5 titled Civil 3D. 6.5.6 AUTODESK REVIT

The Port Authority of New York and New Jersey is moving towards the use of BIM (Building Information Model) technology.. Refer to the E/A Design Division BIM Standard for a description of the processes, procedures, and requirements that are to be followed for the preparation and submission of BIM Models and documents for E/A Design Division projects.

Last Updated: 3/21/2010

Page 11

Engineering Department Manual


E/A Design Division CAD Standard

6.6

PROJECT DIRECTORY STRUCTURE AND FILE NAMING CONVENTION

The E/A Design Division CAD Standard provides a structure for the organization of CAD projects within the department. The primary goals of this structure are to improve coordination between functional groups of E/A Design Division and its consultants, as well as to develop CAD projects in a way that will facilitate the further use of the electronic information beyond the initial contract. 6.6.1 PROJECT DIRECTORY STRUCTURE

All EAD CAD projects are stored on the CAD volume of a central server, which has internally been mapped using the drive letter M:\ The M:\ drive contains a sub-directory for each facility named using its facility code as displayed in Table 6-A. Table 6-A
Facility Code AMT BB BRKMT EP EWR FERRY GB GWB HCMF HELI HH HT IPY JFK JSTC LGA LT MULTI NFC NJMT NLCC OBX PABT PACD PATC PATH PHQ Facility Name Automobile Marine Terminal Bayonne Bridge Brooklyn Port Authority Marine Terminal Elizabeth Port Authority Marine Terminal Newark Liberty International Airport Ferry Transportation Goethals Bridge George Washington Bridge and Bus Terminal Harrison Car Maintenance Facility Downtown Manhattan Heliport Howland Hook Marine Terminal Holland Tunnel Industrial Park at Yonkers John F. Kennedy International Airport Journal Square Transportation Center Laguardia Airport Lincoln Tunnel Multi Facility Projects Newport Financial Center New Jersey Marine Terminals Newark Legal and Communication Center Outerbridge Crossing Port Authority Bus Terminal Port Authority Police Academy Port Authority Technical Center Port Authority Trans-Hudson Corporation Police Headquarters

Last Updated: 3/21/2010

Page 12

Engineering Department Manual


E/A Design Division CAD Standard
Facility Code PN PRTC SWF TEB TLPT WTC Facility Name Port Newark Police Rescue Training Center Stewart International Airport Teterboro Airport Staten Island Teleport World Trade Center

6.6.2

PROJECT IDENTIFIER NUMBER

The Project Identifier Number (PID) is a unique identifier assigned for all EAD projects. The LEA is responsible for getting the PID number from the Project Manager at the kick-off meeting and distributing it to all discipline task leaders involved in the project. The task leader is responsible for distributing the PID number to their outside consultants. The LEA will request the creation of the project folder structure through the use of the on-line form provided on EOL under the Engineering Tools / CAD Support and Training section or by selecting the following link Project Creation Request Form. Refer to Section 6.27.4 titled Request Project Folder Structure. The M:\ drive is divided into Facility Folders, each containing project specific sub-folders. These project folders are named using the eight (8) digit PID number. Figure 6-F illustrates this concept using a project at Goethals Bridge with a PID number of 01234567. 6.6.3 DISCIPLINE FOLDERS

Figure 6-F

Every discipline is provided with a folder in the project directory in which all design related data is to be stored. Each discipline folder has a series of standardized sub-folders which are to contain the various types of design data. Figure 6-G illustrates these standardized Architectural folder as an example. sub-folders using the

The Model, Plotsheet and Publish folders should always contain the current version of all CAD drawings related to the project. For more information on the usage of these folders refer to the section titled Discipline Folder Rules of this standard. For more information on the Plotsheets_CP and DWF_CP folders refer to section 6.12.1 titled Confidential and Privileged Projects of this standard.

6.6.3.1 DISCIPLINE FOLDER RULES

Figure 6-G The Discipline folders are used to share files among all the different disciplines of the Engineering / Architectural Design Division. Sub-folders are not to be created within the discipline folder. The Discipline sub-folders have read-write permissions assigned to the owning discipline.

Last Updated: 3/21/2010

Page 13

Engineering Department Manual


E/A Design Division CAD Standard 6.6.3.2 FROMOTHERPROJECTS FOLDER RULES The FromOtherProjects folder will contain drawings and data that have been taken from other projects that relate to the current project. If a file from another project is required for reference purposes only and is not going to be included as part of the contract set it will be stored in this directory. If a file is required to be part of the contract set then it will be copied to the Model folder and must comply with the current EAD CAD Standard. Sub-folders are permitted within the FromOtherProjects folder (Refer to the Section 6.6.9 titled Folder Naming Convention for proper usage). The FromOtherProjects folder has read-write permissions assigned to the owning discipline. Other disciplines have no access to the FromOtherProjects folder. The FromOtherProjects folder will not be archived with the project. 6.6.3.3 MANAGEMENTDOCS FOLDER RULES The ManagementDocs folder will contain all non-drawing or photo related project data. Spreadsheets, documents, specifications, memos, estimates, etc. will be stored in this folder. Sub-folders are permitted within the ManagementDocs folder (Refer to the Section 6.6.9 titled Folder Naming Convention for proper usage). The ManagementDocs folder has read-write permissions assigned to the owning discipline. Other disciplines have no access to the ManagementDocs folder. The ManagementDocs folder will be archived with the project. 6.6.3.4 MODEL FOLDER RULES All design work and annotation must be stored inside AutoCAD drawings saved within the Model folder. The EAD CAD Standard refers to these design drawings as Model files. Images and Office documents referenced or linked by drawing files will also be stored in the Model folder and must comply with the rules for Model files. Sub-folders are not to be created within the Model folder, with the exception of the folders created when ACA, LDC or MEP projects are used. (Refer to Section 6.5.3 titled AutoDesk AutoCAD Architecture and AutoDesk AutoCAD MEP or Section 6.5.4 titled AutoDesk Land Desktop Companion for proper usage) The Model folder has read-write permissions assigned to the owning discipline. Other disciplines have read permissions assigned to the Model folder. The Model folder will be archived with the project. 6.6.3.5 PHOTOS FOLDER RULES The Photos folder will contain all digital photographs relevant to the project, with the exception of those used on contract drawings. Drawings are not permitted to reference photographs from this folder. In order to reference a photograph within a drawing file, copy the image into the Model folder and refer to section 6.6.3.4 titled Model Folder Rules for proper usage. References to OLE objects are not permitted. Sub-folders are permitted within the Photos folder (Refer to the Section 6.6.9 titled Folder Naming Convention for proper usage). There are no file naming requirements for images stored within the Photos folder. Last Updated: 3/21/2010 Page 14

Engineering Department Manual


E/A Design Division CAD Standard The Photos folder has read-write permissions assigned to the owning discipline. Other disciplines have no access to the Photos folder. The Photos folder will be archived with the project. 6.6.3.6 PLOTSHEETS FOLDER RULES All layouts for plotted sheets will be saved inside AutoCAD drawings stored within the Plotsheets folder. The EAD CAD Standard refers to these layout drawings as Plotsheet Files. These files are assembled sheets used for plotting. These drawings consist of a series of external references. Sub-folders are not permitted within the Plotsheets folder Only Plotsheet files will be stored within the Plotsheets folder. The Plotsheets folder has read-write permissions assigned to the owning discipline. Other disciplines have read permissions assigned to the Plotsheets folder. The Plotsheets folder will be archived with the project. No line work or annotation is allowed in either Model Space or Paper Space of the Plotsheet files with the following exceptions: Blocks provided within this standard whose name begins with Drawing_Info Match lines and associated Match line annotations. Revision clouds and associated Revision cloud annotations. Scale Bars North Arrows View Titles All paper drawings in the Contract Set will have a corresponding Plotsheet file in the Plotsheets folder, the only exception is the Title Sheet. Multiple contract documents can be saved in a single Plotsheet file, with the following stipulations: Only consecutive drawings may be stored on multiple Paper Space tabs in a single drawing file. Layout tabs will be named after their corresponding sheet numbers, in sequential order. 6.6.3.7 DWF FOLDER RULES A Design Web Format file (DWF) is a highly compressed non-editable file format, created from drawing files. DWF files will be created and stored in the DWF folder each time a submittal milestone is reached. The DWF folder will always contain the latest version of the DWF file. Sub-folders are not permitted within the DWF folder. The DWF folder has read-write permissions assigned to the owning discipline. Other disciplines have read permissions assigned to the DWF folder. The DWF folder will be archived with the project.

Last Updated: 3/21/2010

Page 15

Engineering Department Manual


E/A Design Division CAD Standard 6.6.3.8 PUBLISH FOLDER RULES The Publish folder will be used as a sharing mechanism between disciplines. A discipline may copy Model files into its own Publish folder, making them available for other disciplines to reference. Other disciplines are not permitted to copy these files, but will instead externally reference them directly from the owners Publish folder. The lead disciplines Publish folder will contain the Contract Border. There will be only one Contract Border per project. The only exception to this rule is when new drawings are added to the Contract Set as part of a Stage IV PACC. Refer to Section 6.26 titled Appendix J Contract Borders and Title Sheets for instructions. It is important that this methodology for referencing design files from other disciplines is followed. If a user copies design files from another disciplines Model, Plotsheets or Publish folder then they must take ownership of the file. By taking ownership the discipline copying the file will then be responsible for EAD CAD Standards compliance of that file as if it were created by that discipline. Sub-folders are not permitted within the Publish folder. Only copies of Model files shall be stored in the Publish folder, with the exception of the Contract Border. A discipline will not reference a file from within its own Publish folder, with the exception of the Contract Border for the Lead Discipline. The Publish folder has read-write permissions assigned to the owning discipline. Other disciplines have read permissions assigned to the Publish folder. The Publish folder will be archived with the project. 6.6.3.9 HISTORY FOLDER RULES If a single file is to be published more than once, the file that exists in the Publish folder will be moved to a dated sub-folder within the History folder. The updated version of the file will then be copied into the root of the Publish folder. This will allow other disciplines to continue to reference older versions of reference drawings if required by their design schedule by changing the external reference path to the dated subfolder within the History folder. Sub-folders are permitted within the History folder (Refer to the Section 6.6.9 titled Folder Naming Convention for proper usage). Only copies of previously Published files will be copied to the History folder. The History folder has read-write permissions assigned to the owning discipline. Other disciplines have read permissions assigned to the History folder. The History folder will be archived with the project. 6.6.3.10 RECEIVED FOLDER RULES

The Received folder will contain a dated archive of design information received from outside sources. This folder is intended as a record to identify exactly what information consultants provided on what date. Sub-folders are permitted within the Received folder (Refer to the Section 6.6.9 titled Folder Naming Convention for proper usage). The Received folder has read-write permissions assigned to the owning discipline. Other disciplines have no access to the Received folder. Last Updated: 3/21/2010 Page 16

Engineering Department Manual


E/A Design Division CAD Standard The Received folder will not be archived with the project. 6.6.3.11 RELEASED FOLDER RULES

The Released folder will contain a dated archive of design information provided to outside sources. This folder is intended as a record to identify exactly what information consultants were provided with and on what date. Sub-folders are permitted within the Released folder (Refer to the Section 6.6.9 titled Folder Naming Convention for proper usage). The Released folder has read-write permissions assigned to the owning discipline. Other disciplines have no access to the Released folder. The Released folder will not be archived with the project. 6.6.3.12 SCHEMES FOLDER RULES

The Schemes folder will contain various schemes of a design as well as any temporary design data. This folder provides the designer with an area in which to make trial changes to a design and a place to store temporary files. If a scheme is created and is later chosen as the final design version, the files stored under that scheme are to be copied to the Model folder. Sub-folders are permitted within the Schemes folder (Refer to the Section 6.6.9 titled Folder Naming Convention for proper usage). The Received folder has read-write permissions assigned to the owning discipline. Other disciplines have no access to the Received folder. The Shemes folder will not be archived with the project. 6.6.3.13 SUBMITTALS FOLDER RULES

The Submittals folder is a location for storing project information as it appears at each milestone of the project. While the root Model, Plotsheets and Publish folders contain the current versions of drawings which will change throughout the life cycle of the project, the Submittals folder will preserve the state of those drawings at the moment of each milestone. Sub-folders have been created for each submission milestone from Stage I through Stage IV, Figure 6-H displays the subfolders that have been created. Sub-folders are permitted within the StageIII_PAReview, StageIII_Addendum and StageIV_PACC folders, by replacing the XX with the proper submission number The Submittals folder has read-write permissions assigned to the owning discipline. Other disciplines have read permissions assigned to the Submittals folder. The Submittals folder will be archived with the project. Figure 6-H

For more information regarding the specific submittal milestones refer to Section 6.7.10 titled Submissions. Last Updated: 3/21/2010 Page 17

Engineering Department Manual


E/A Design Division CAD Standard 6.6.4 SAMPLE PROJECT

To simplify the exchange of information between the various PANYNJ departments, divisions and function groups as well as between consultants and contractors, every attempt will be made to adhere to both the drive mapping and directory structures defined within this section. A sample project folder structure has been provided with the EAD CAD Standard as shown in Figure 6-I. Consultants are required to use this project folder structure replacing the word Facility Name with the Facility Code provided in section 6.6.1 titled Project Directory Structure and the letters PID with the eight (8) digit Project Identifier Number proved by the LEA. A copy of the project folder structure can be found at: EAD_Standard\All Disciplines\Sample Project\

Figure 6-I 6.6.5 FILE NAMING CONVENTION All electronic project files such as DWG, DWF, Images and Office documents referenced by a contract drawing, will be named following the EAD CAD Standard File Naming Convention. 6.6.5.1 DISCIPLINE CODES There are eight (8) disciplines within the E/A Design Division of the PANYNJ. All files referenced by contract drawings will be named beginning with the appropriate Discipline Code. The only exception to this rule is the Contract Border file. Table 6-B
Code A C E N G M S T Discipline Architectural Civil Electrical Environmental Geotechnical Mechanical Structural Traffic

6.6.5.2 CONTRACT BORDER FILE The Contract Border file contains general information about the project. This drawing will be named using the eight (8) digit PID number followed by a dash (-) and then the initials CB. Since one Contract Border file is used by all disciplines of the project, no discipline code is used in its file name. The filename will also contain no spaces or description. The filename will take the form of: PID-CB.dwg

Last Updated: 3/21/2010

Page 18

Engineering Department Manual


E/A Design Division CAD Standard
Acronym PID CB Description Eight Digit Project Identifier Number Contract Border

For example, the Architectural discipline is the Lead Discipline for a project with a PID number of 01234567. The Contract Border shall be named as follows: 01234567-CB.dwg Consultants may create their own Contract Border file only if they are the Lead Discipline. Otherwise, they will request the Contract Border from their EAD Task Leader and will place it in the Lead Disciplines Publish folder. If new drawings are added to the Contract Set during a Stage III Addendum, the original Contract Border will be used and the new issue date will be included within the Revision Stamp. If new drawings are added to the Contract Set during a Stage IV PACC, a new Contract Border will be issued by the Lead Discipline. The new Contract Border will have a dash (-) followed by the date appended at the end of the file name in the form of -YYYY_MM_DD. The original Contract Border will remain un-changed and both files will co-exist within the Publish folder. For example, the Traffic discipline is the Lead Discipline for a project with a PID number of 01234567 and new drawings are to be added to the Contract Set for a Stage IV PACC occurring on November 21st, 2009. A new Contract Border will be issued and named as follows: 01234567-CB-2009_11_21.dwg 6.6.5.3 MODEL FILES Model files are working drawing files containing the actual design geometry and annotations; they may also include externally referenced files from either the disciplines own Model folder or other disciplines Publish folders. Model files will be named beginning with the Discipline Code, followed by the eight digit PID number, a Model File Plan Type, an optional Sequence modifier and an optional User Description. Refer to the list of approved Model File Plan Types listed in Table 6-C. Once defined a model files name will not change through the life of the project. This restriction is required due to the nature of externally referencing Model files. The filename will take the form of: DPID-FP01-UserDescription.dwg
Acronym D PID FP 01 UserDescription Description Discipline Code (Refer to Table 6-B) Eight Digit Project Identifier Number Model File Plan Type (Refer to Table 6-C) Sequence Modifier (If used will be two digits) A description of up to 24 characters, including spaces. The following characters are not permitted <>/\:;?*|,=&%

Table 6-C lists all allowable Model File Plan Types. For a listing of common Model File Plan Types for particular disciplines refer to that specific disciplines appendix. Last Updated: 3/21/2010 Page 19

Engineering Department Manual


E/A Design Division CAD Standard Table 6-C
Model File Plan Type 3D AA ALN AN AP ASL BSE CD CFP COM CP CPP CS CSD D DAT DTL EL EM EP EV FA FD FNP FP FPW FR FS GP GRD GT HDP HP ICM IDX IEL IMG Description 3D Isometric Asbestos Abatement Alignment Plan Annotations Auxiliary Power Plan Asbestos Sample Location Background Drawing Communication System Plan Concrete Framing Plan Communication Plan Control Plan Corrosion Protection Plan Construction Staging Control Schematic Decking Plan Microsoft Office Document Detail Exterior Elevation EMCS Plan Enlarge Plan Environmental Plan Fire Alarm Foundation Plan Furniture Plan Floor Plan Floor Plan Wall Framing Plan Fire Suppression Plan Grounding Plan Grading Plan Geotechnical Plan HVAC Ductwork Plan Hydraulic Profile ITS Communication Plan Index of Drawings Interior Elevation Image Model File Plan Type JL KP LA LIP LP LR LSL MD MH MIS MT NOT ONL PAV PB PIP PJ PL PLP PM PP PPL PPP PRF QP RCP RE RI RL RM RP SCH SE SEC SF SG SK Description Joist Girder Load Diagram Keyplan Lead Abatement Lighting Plan Landscape Plan Lightning Protection Plan Lead Paint Sample Location Machine Design Plan Material Handling Plan Miscellaneous Maintenance of Traffic Plan Notes and Specifications Plan One Line Diagram Paving Plan Presentation Border Piping Plan Project Location Part Plan Plumbing Plan Pavement Marking Plan Power Plan Pre-cast Panel Layout Plan Pollution Prevention Plan Profile Equipment Plan Reflected Ceiling Plan Reinforcement Plan Riser Diagram Removal Remediation Plan Roof Plan Schedule Soil Erosion Plan Section Stair Framing Plan Signal Plan Sketch

Last Updated: 3/21/2010

Page 20

Engineering Department Manual


E/A Design Division CAD Standard
Model File Plan Type SNP SO SP SPK SPP ST STG TB TOP Description Sign Plan Sequence of Operation Plan Site Plan Sprinkler Plan Specialty Piping Plan Steel Framing Plan Staging Plan Truss Bracing Plan Topographic Plan Model File Plan Type TRK UTL WD WET WG WTP WWT XB Description Track Plan Utility Plan Wiring Diagram Wetland Plan Wind Girt Plan Water Treatment Plan Wastewater Treatment Plan X Bracing Plan

The Sequence Modifier is restricted to the following two options: Option 1 Without using the Sequence Modifier For Example: M01234567-SPK-Level 2 North Wing.dwg M01234567-SPK-Level 2 South Wing.dwg M01234567-SPK-Level 4 North Wing.dwg M01234567-SPK-Level 4 South Wing.dwg Option 2 Using the Sequence Modifier For Example: M01234567-SPK02-North Wing.dwg M01234567-SPK02-South Wing.dwg M01234567-SPK04-North Wing.dwg M01234567-SPK04-South Wing.dwg Note that each discipline can choose which of the options they will follow for the project. 6.6.6 PLOTSHEET FILES

Plotsheet files are drawings assembled as sheets for plotting consisting of an externally referenced Contract Border, an inserted Drawing_Info block and externally referenced Model files from either the disciplines own Model folder or other disciplines Publish folders. Plotsheet files will be named beginning with the Discipline Code, followed by the eight digit PID number, followed by a dash (-), followed by the Series Modifier and then the Sheet Number or Sheet Number Range. The Plotsheet file is not permitted to have a user description appended to its name. The filename will take the form of: DPID-PTXX01.dwg (For Plotsheet files containing a single layout) DPID-PTXX01_PTXX20.dwg (For Plotsheet files containing multiple layouts)

Last Updated: 3/21/2010

Page 21

Engineering Department Manual


E/A Design Division CAD Standard
Acronym D PID PT XX 01 XX01_XX20 Description Discipline Code (Refer to Table 6-B) Eight Digit Project Identifier Number Plotsheet Plan Type (Refer to Table 6-D) Series Modifier (Refer to 6.6.8) Single Sheet Number Starting Layout Tab Sheet Number to Ending Layout Tab Sheet Number

6.6.6.1 PLOTSHEET PLAN TYPE Plotsheet Plan Types are categories used for organizing Contract Drawings and refer to the single or double letters that appear before the sheet number in the lower right hand corner of each Plotsheet. A listing of the Plotsheet Plan Types usable by specific discipline appears in Table 6-D. Table 6-D
Useable By All Disciplines Architectural Civil Description General Plan Architectural Plan Landscape Plan Civil Plan Construction Staging or Sequence Plan Maintenance of Traffic Electrical Electrical Plan Corrosion Protection Plan Electronics Plan Environmental Geotechnical Mechanical Environmental Plan Geotechnical Plan Mechanical Plan Baggage Handling Plan Fire Protection Plan Plumbing Plan Sprinkler Plan Vertical Transportation Plan Structural Traffic Structural Plan Traffic Plan Construction Staging or Sequence Plan Maintenance of Traffic Plan Signal Plan Plotsheet Plan Type G A LS C CS MT E CP ES N GT M B FP P SP VT S T CS MT SG

For Example: M01234567-SP001.dwg E01234567-ES001_ES004.dwg Last Updated: March 2010 Page 22

Engineering Department Manual


E/A Design Division CAD Standard

6.6.7

DWF FILES

A DWF file is a non-editable highly compressed file format created from a DWG file. DWF files will be named beginning with the Discipline Code, followed by the eight digit PID number, followed by a dash (-) and then the Sheet Number Range. The DWF file is not permitted to have a user description appended to its name. Two forms of DWF files can exist, Single Sheet and Multi Sheet. The DWF filename will take the form of: DPID-PTXX01.dwf (Single Sheet) DPID-PTXX01_PTXX20.dwf (Multi Sheet)
Acronym D PID PT XX 01 XX01_XX20 Description Discipline Code (Refer to Table 6-B) Eight Digit Project Identifier Number Plotsheet Plan Type (Refer to Table 6-D) Series Modifier (Refer to Section 6.6.8) Single Sheet Number Starting Sheet Number to Ending Sheet Number

DWF files will be submitted as multi-sheet files at every submittal milestone of the project and will be created: From the current set of PlotSheet files Full Size (either 22x34 or 34x56) In black and white In consecutive order Grouped together by Plotsheet Plan Type and by Series number (if used) When using Series, the DWF files will be named not only by grouping them together by Plotsheet Plan Type but also by their Series number. PDF files are not permitted as substitutions for DWF files. Option One (Without Series) For Example: T01234567-G001_G007.dwf T01234567-CS001_CS003.dwf T01234567-T001_T037.dwf Option Two (With Series Level One) For Example: T01234567-G101_G107.dwf T01234567-T101_T137.dwf T01234567-T201_T207.dwf Last Updated: March 2010 Page 23

Engineering Department Manual


E/A Design Division CAD Standard T01234567-T501_T503.dwf Option Three (With Series Level Two) For Example: T01234567-G0101_G0107.dwf T01234567-T0101_T0137.dwf T01234567-T0201_T0207.dwf T01234567-T1201_T1203.dwf 6.6.8 DRAWING NUMBER CONVENTION

A Series is a numbering code used to organize sheets in the Contract Drawing Set. A description of what each number in a series represents will be defined at the start of every project by each disciplines Task Leader. At the start of each project the LEA will determine whether a one or a two digit series is to be used for all disciplines of the project. For Example: The LEA on a project is from Structural and decides that only 9 or less series are needed. Structural would select option one. Electrical, however, decides that 10 or more series are needed. Electrical would select option two. Since the LEA is from the Structural discipline the determination for all disciplines is to be made by them if Electrical requires the two digit series option then they must request that the LEA use that option for all disciplines. These two formats cannot co-exist on the same project. Option One (One digit series Figure 6-J) For projects with nine or less series the sheet number format will include a one or two letter Plotsheet Plan Type followed by a one digit series number followed by a two digit sheet counter number. o o o Use digits 1 through 9 as the series numbers Series numbers can be skipped. Counter numbers must be consecutive numbers beginning at 01 for each series.

Option Two (Two digit series Figure 6-K) For projects with ten or more series the sheet number format will include a one or two letter Plotsheet Plan Type followed by a two digit series number followed by a two digit sheet counter number. o o o Use digits 01 through 99 as the series numbers Series numbers can be skipped Counter numbers must be consecutive numbers beginning at 01 for each series.

Option Three (Without Series Figure 6-L) For projects that are not using a series the sheet number format will include a one or two letter Plotsheet Plan Type followed by a three digit sheet counter number. o Counter numbers must be consecutive numbers beginning at 001.

The Sheet Number will take the form of:

Last Updated: March 2010

Page 24

Engineering Department Manual


E/A Design Division CAD Standard
Counter Number (001 through 999) 001 Counter Number (01 through 99) Counter Number (01 through 99)

Series Number (01 through 09)

Series Number (1 through 9)

Plotsheet Plan Type

Plotsheet Plan Type

01

01

01

Figure 6-J

Figure 6-K

The following images display how the three options would appear on a Structural Plotsheet.

Option One 6.6.9 FOLDER NAMING CONVENTION

Option Two

Option Three

All sub-folders created within the pre-defined folder structure will be named using the date, followed by a dash (-), followed by a User Description and will take the form of: YYYY_MM_DD-User Description
Acronym YYYY MM DD User Description Description Four digit Year Two digit Month Two digit Day A description of up to 24 characters, including spaces. The following characters are not permitted <>/\:;?*|,=&%

6.7

CAD PRACTICES AND PROCEDURES

CAD drawing files must be consistently formatted in order to provide an effective method of data dissemination and retrieval. To that end, these standards will guide the user in the requirements of layer naming, graphic symbology, lettering styles, drawing units and other drawing related features. 6.7.1 COORDINATE SYSTEMS

In an effort to organize, consolidate and standardize the information generated and consumed by all divisions within the agency, Coordinate Systems must be used on all projects. The objective of this requirement is to make the data files easier for users to identify and integrate in planning and design. The default horizontal systems are the State Plane NAD83 New York East and Long Island Foot systems and default vertical system is the State Plane NGVD88 system. If another Coordinate System is to be used on a project that determination must be made by the LEA at the beginning of the project.

Last Updated: March 2010

Plotsheet Plan Type S

Figure 6-L

Page 25

Engineering Department Manual


E/A Design Division CAD Standard 6.7.2 LAYERING SCHEME DEFINITION

All layers contained within E/A Design Division drawings have been defined using variations of the TriServices and the AIA layer guidelines and standards. All disciplines use a layer standard that is similar. The major components of a standard layer name are defined as follows: Discipline-Major-Minor-Description-Phase
Acronym Discipline Major Minor Description Phase Description Discipline Code (Refer to Table 6-E) Major grouping of features that have common characteristics Sub grouping of Major category Extended description of layers for clarity Indication of the informations current Phase (Refer to Table 6-F)

Table 6-E
Code A L C E N G M F P S T GN Discipline Architectural Landscape Civil Electrical Environmental Geotechnical Mechanical Fire Protection Plumbing Structural Traffic General Code EXST OTHR RELO RMVL TEMP

Table 6-F
Phase Existing Work by Others Relocation Removal Temporary

Note that the discipline codes listed in Table 6-E are for layer definitions only and may not reflect the correct discipline codes for file naming. For Example: C-UTIL-STRM-IDEN or C-UTIL-STRM-SYMB-RELO or C-UTIL-STRM-SYMB-RMVL The E/A Design Division layering stratagem consists of eleven discipline groups and a general group that corresponds to spatial data layers to assist in the isolation of information for design purposes and for the translation and use with GIS. Although every attempt has been made to create an all-encompassing standard, reality dictates that additions will need to be made to the layer stratagem. In the case that additions are required, they will only be accepted as additions to minor or description categories. If an addition is required for the discipline or major categories then a Request to Change Standard Form is required. Refer to Section 6.28 titled Appendix L Request to Change Standard. 6.7.3 ENTITY AND LAYER LINETYPES

Standard E/A Design Division linetypes have been created for use with all design documents. These linetypes have been assigned to their respective layers in the <Layers.dwt> drawings, which have been provided for each discipline as part of this standard. Additional linetypes have been created for special circumstances when the lettering within a linetype needs to be rotated. Many of the linetypes supplied require the use of a textstyle named LINEFONT, starting a drawing with the template drawings provided as part of this standard will ensure that the linetypes are loaded correctly. All entities will have their Last Updated: March 2010 Page 26

Engineering Department Manual


E/A Design Division CAD Standard linetype assigned bylayer and not byentity. The two exceptions to this are: Symbol entities that have their linetypes assigned to byblock. The use of short or rotated variations of a linetype needed for a particular entity. To ensure correct linetype scaling settings for Plotsheet drawings the LTScale and PSLtscale variables will be set to 1. The sets all linetypes to be scaled based on the paper space viewport scale factor. For design (MODEL) files, which utilize model space, will have the LTScale variable set to the drawing scale. For discipline specific linetype usages refer to Sections 6.17 through 6.24. 6.7.4 ENTITY AND LAYER COLORS

All entities will be drawn on the specified layers and must have color assigned to bylayer and not byentity. Layer color assignments are included in the layer definitions provided. For discipline specific color usages refer to Sections 6.17 through 6.24. 6.7.5 SYMBOLOGY

A symbol is defined as a pre-arranged group of geometry that can be inserted at scale into a drawing. The AutoCAD term for a symbol by this definition is block. There are two (2) types of symbols provided in this standard, Scalable and Non-Scalable symbols. Standard E/A Design Division symbols have been provided as part of this standard. For discipline specific symbol definitions refer to Sections 6.17 through 6.24. 6.7.5.1 SCALABLE SYMBOLS Scalable symbols are created with the intent that they will appear the same size when plotted at different scales. Symbols are created on Layer 0 and will automatically take on the characteristics of the layer they are inserted on. All symbols will be inserted on the layer identified within this standard. For ease of use, the insertion scale factor of each scalable symbol will depend on the plot scale. For Example: If the scale of the viewport is 1:30, then each symbol inserted in the drawing will be scaled up by a factor of 30. If the scale of the viewport is 1/8=1-0, the symbol will be inserted into the drawing with a scale factor of 96. 6.7.5.2 NON-SCALABLE SYMBOLS Non-Scalable symbols are created with the intent that they will appear at true size for all plot scales. Symbols are created on Layer 0 and will automatically take on the characteristics of the layer they are inserted on. All symbols will be inserted on the layer identified within this standard. The insertion scale factor for all Non-Scalable symbols will be 1.

Last Updated: March 2010

Page 27

Engineering Department Manual


E/A Design Division CAD Standard 6.7.5.3 CREATING SYMBOLS Symbols must be documented and supplied to the CAD committee in digital format as a single AutoCAD drawing file accompanied by a plot of the symbol and a Request to Change Standard Form found in Section 6.28 titled Appendix L Request to Change Standard. Symbols will be created on Layer 0. Other layers may be present in the drawing for supplemental information such as text within the symbol. Symbols will be created using the current version of AutoCAD software in use by the E/A Design Division. Colors and Linetypes will always be set to bylayer. Text within the symbol will utilize one of the Text Styles provided within this standard so that it is legible upon plotting. The symbol will be drawn so that the insertion point is located appropriately and is at 0,0,0. The base of the drawing will be set to 0,0,0. The symbol drawing will be purged of all unused blocks, layers, linetypes, text styles, etc. 6.7.6 PLOTTED LINEWEIGHTS Table 6-G
Variable Color Dither Virtual Pen Number Linetype Adaptive Line End Style Line Join Style Fill Style Value Black On Automatic Use Object Linetype On Use Object End Style Miter Use Object Fill Style

The colors used in the layer definitions provided within this standard correspond to plotted pen weights. AutoCAD products make use of a CTB file to assign pen weights to object colors. All E/A Design Division Contract Drawings are to be plotted using the PA-Master.ctb file that is provided with this standard. Many variables within the CTB file remain constant throughout the pen assignments, these variables are defined in Table 6-G. The pen numbers, lineweights and percent screening assigned to the pens used in the PAMasterFull.ctb file are displayed in Table 6-H. The values displayed in Table 6-G and Table 6-H are for Contract Drawings, disciplines are permitted to use their own ctb files for presentation purposes.

Last Updated: March 2010

Page 28

Engineering Department Manual


E/A Design Division CAD Standard Table 6-H
Pen 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 20 21 23 24 30 31 32 33 35 37 40 41 42 43 46 50 Color Weight 0.0100 0.0140 0.0200 0.0360 0.0080 0.0240 0.0080 0.0080 0.0080 0.0120 0.0180 0.0100 0.0280 0.0080 0.0140 0.0180 0.0080 0.0200 0.0320 0.0400 0.0080 0.0200 0.0240 0.0240 0.0080 0.0200 0.0140 0.0080 0.0240 0.0040 0.0200 Screen 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% Pen 51 52 53 54 60 61 62 71 80 81 82 83 90 92 93 96 100 110 120 121 130 131 132 133 140 141 142 143 144 148 150 Color Weight 0.0280 0.0240 0.0040 0.0100 0.0160 0.0100 0.0080 0.0100 0.0100 0.0200 0.0140 0.0080 0.0240 0.0120 0.0080 0.0100 0.0160 0.0080 0.0200 0.0140 0.0100 0.0200 0.0040 0.0080 0.0240 0.0320 0.0180 0.0080 0.0720 0.0100 0.0260 Screen 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 30% 100% Pen 170 172 180 190 191 192 194 200 201 202 210 211 212 220 221 222 223 230 231 232 234 240 241 242 244 250 251 252 253 254 255 Color Weight 0.0200 0.0240 0.0040 0.0080 0.0140 0.0240 0.0200 0.0100 0.0280 0.0100 0.0160 0.0320 0.0140 0.0200 0.0040 0.0100 0.0040 0.0160 0.0240 0.0440 0.0160 0.0040 0.0080 0.0040 0.0080 0.0080 0.0080 0.0080 0.0080 0.0080 0.0480 Screen 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 80% 70% 60% 50% 40% 100%

Last Updated: March 2010

Page 29

Engineering Department Manual


E/A Design Division CAD Standard 6.7.7 TEXT STYLES AND HEIGHTS

To promote consistency in Contract Drawings as well as prevent the use of third-party un-licensed AutoCAD font files, only the Helv-2F.shx, Helv-M.shx , Romand.shx and Romans.shx fonts are permitted for use on E/A Design Division Contract Drawings. Nine Text Styles have been provided as part of this standard. Five of the Text Styles provided are used for Contract Border, Drawing Information or Linetype definitions and are not permitted for general use by the disciplines. The remaining four Text Styles provided, which are permitted for use by the disciplines are created as annotative styles. Annotative styles allow the AutoCAD product to scale the text heights appropriately based on the scale of the plotted drawing. The Text Styles provided are:
Text Style PA - 1-10th PA - 1.5-10th PA - 2-10th PA - 2.5-10th Linefont Helv-2F Helv-M RomanD RomanS Plotted Height 0.10 0.15 0.20 0.25 0.10 Varies Varies Varies Varies Annotative Yes Yes Yes Yes No No No No No Font Romans.shx Romans.shx Romans.shx Helv-M.shx Romans.shx Helv-2F.shx Helv-M.shx Romand.shx Romans.shx Description of Usage Normal Text Headings Titles Alternate Titles Linetype Definitions Contract Border and Drawing Info Contract Border and Drawing Info Contract Border and Drawing Info Contract Border and Drawing Info Usable by Disciplines Yes Yes Yes Yes No No No No No

6.7.8

DIMENSION AND LEADER STYLES

To promote consistency in Contract Drawings only the Dimension and Leader Styles that have been provided as part of this standard are permitted for use. The Three Dimension Styles and eight MultiLeader Styles that have been provided are:
Dimension Style PA-Arrow PA-Arrow-Deci PA-Tick Arrow Head Closed Filled Arrow Closed Filled Arrow Tick Content 0.10 Mtext 0.10 Mtext 0.10 Mtext Unit Type Inches Feet Inches

Multi-Leader Style PA-Arrow PA-Loop PA-Circle PA-Dot PA-Integral PA-DOT-Keynote-Box PA-DOT-Keynote-Circle PA-DOT-Keynote-Hex

Arrow Head Closed Filled Arrow Open Loop Dot Blank Dot Integral Dot Dot Dot

Content 0.10 Mtext 0.10 Mtext 0.10 Mtext 0.10 Mtext 0.10 Mtext Box Circle Hexagon

Last Updated: March 2010

Page 30

Engineering Department Manual


E/A Design Division CAD Standard 6.7.9 TABLE STYLES

As with the text and dimension styles, the EAD CAD Standard has provided Table Styles as part of this standard in an attempt to promote consistency throughout the creation of Contract Drawings.
Table Style PA-Index PA-Legend Description of Usage Drawing Index General Legends

6.7.10 EXTERNAL REFERENCE FILES All external reference drawings will be attached as Overlays. By adhering to this process, all users will be able to use drawings within their own disciplines as well as drawings from other disciplines without concern for circular references and other potential problems. The path type will be set to Relative Path, for both, external reference drawings and external reference images, this process will ensure the proper exchange of drawings and/or images between in-house staff and outside consultants. 6.7.11 SUBMISSIONS CAD files in DWG and DWF format, accompanied with hardcopies are required at every Submittal Milestone. Until project completion, all current working drawings are saved in the MODEL, PLOTSHEETS and PUBLISH folders of each disciplines root directory. At every Submittal milestone, the working project information will be copied into the SUBMITTALS folder for archiving, in order to preserve the state of the drawings at the moment of that milestone. At the completion of every milestone, each discipline will copy its MODEL, PLOTSHEETS and PUBLISH folders, along with the MANAGEMENTDOCS and PHOTOS folders, into the appropriate milestone sub-folder within SUBMITTALS. Refer to Section 6.6.3.13 titled Submittals Folder Rules for a listing of Submittal Folders provided. Once the folders have been copied, the involved Task Leaders will notify the LEA, who will then notify the CAD Support Group by filling out the Project Archival Request Form on EOL. Refer to Section 6.27.2 titled Request Project Archival. Upon notification, the CAD Support Group will move the files to the Archive server, mapped internally as the N:\ drive, leaving behind a text file named ARCHIVED YYYYMM-DD.txt containing the exact location where the files can be found. The CAD Support Group will only move files from the disciplines SUBMITTALS folder to the ARCHIVE server. The SUBMITTALS folder is for internal use only. Consultants are required to submit the entire Project Folder Structure as outlined in Section 6.4 titled Digital Submittal Requirements, containing not only the Discipline folder in which their drawings are saved but also all other Discipline folders from which external references were made. Consultants will submit their folder structure directly to their own Disciplines Task Leader. The Task Leader will copy the consultants MODEL, PLOTSHEETS and PUBLISH folders, along with the MANAGEMENTDOCS and PHOTOS folders, into both the disciplines root directory and the appropriate milestone sub-folder within SUBMITTALS.

Last Updated: March 2010

Page 31

Engineering Department Manual


E/A Design Division CAD Standard 6.7.11.1 STAGEI_100PERCENT

Stage I (Conceptual Design) is necessary for some projects to develop design concepts, determine anticipated construction costs and schedules, and to compare alternatives before proceeding with Design Development (Stage II) or Final Design (Stage III). 6.7.11.2 STAGEII_100PERCENT

Stage II (Design Development) is necessary to develop the chosen design concept, further refine anticipated construction costs and schedules before proceeding with contract documents. 6.7.11.3 STAGEIII_PA-REVIEW

The Stage III (Final Design) effort includes preparation of contract documents that will be used for construction. The procedures vary for alternate delivery methods such as Quick Bid Contracts, Work Order Contracts, Design/Build Contracts and Design/Build/Operate/Maintain Contracts. PA Review usually happens when the project is between 90% to 95% complete, this may vary depending on the project specifics. When a project reaches PA-Review, drawings are required so the Electronic Review Process can begin. 6.7.11.4 STAGEIII_AS-ADVERTISED-SIGNED-SET

The As-Advertised-Signed-Set is when the project reaches 100% Submission and Mylars are plotted and signed. 6.7.11.5 STAGEIII_ADDENDUM

Addenda happen after the Mylar Set is plotted and signed. Some Addenda might not contain drawing modifications, some might only contain Specs, for this reason, the StageIII_Addendum Set might contain non-consecutive Addenda sub-folders. This folder should only contain the Addenda sub-folder in which drawings were required. This folder should not contain the entire set of CAD files it should only contain the Addenda files. 6.7.11.6 STAGEIII_AS-BID

The As-Bid Set is the Bid and Awarded Set of Drawings, which incorporates all the addenda that have been issued. 6.7.11.7 STAGEIV_PACC

The PACC Set (Post Award Contract Changes) contains drawings that have been modified or new drawings that have been issued after the Contract was awarded. 6.7.11.8 STAGEIV_DRAWING-OF-RECORD

The Drawing-of-Record Set is the set of drawings created after construction is completed.

Last Updated: March 2010

Page 32

Engineering Department Manual


E/A Design Division CAD Standard

6.8

CAD ENVIRONMENT SETUP

In order to plot successfully using this standard, some configuration of the AutoCAD environment will be necessary. This configuration will only need to be done once and will streamline plotting moving forward. 6.8.1 AUTOCAD 2010 CONFIGURATION (PLOTTING BY LAYOUT)

AutoCAD 2010 options must be modified to insure proper placement of the Contract Border in the paper space layout environment. To make the required modifications, right click within the drawing pane and select Options. From within the Options dialog, select the Display tab and make the changes shown in Figure 6-M to the Layout Elements portion of the tab and then select OK.

Figure 6-M The Layout Elements settings that were changed affect the workstation and will not need to be reconfigured in future sessions. 6.8.2 TEMPLATE DRAWING SETUP

For proper plotting and consistency, the EAD CAD Standard makes use of template drawing files. Supplied with this standard are two template files, PA-deci-units.dwt for Decimal units and PA-archunits.dwt for Architectural units. To install either of these template drawings, copy them to the appropriate Template directory in your AutoCAD environment install directory. Both templates are essentially blank drawings saved with the extension .dwt, that have been started from scratch, been assigned a unity type and make use of a CTB file. In addition both templates have the Text Style LINEFONT defined for use with the EAD CAD Standard linetypes. If you currently have a drawing template ensure that your template has the Use Color Dependant Plot Styles option selected and the Default plot style table set to PA-MasterFULL.ctb as shown in Figure 6-N. These options are found under the Plot Style Table Settings button of the Plot and Publish tab in the Options dialog box.

Figure 6-N

Last Updated: March 2010

Page 33

Engineering Department Manual


E/A Design Division CAD Standard 6.8.3 UNITS

Every object created is measured in drawing units. Before drawing can begin, the drawing units used will need to be decided based on the type of plan being drawn. All drawings will be created at actual size with the unit convention decided on. For Example: For a drawing with units assigned to inches a distance of one drawing unit represents one inch in realworld units. Template files have been provided for both, Architectural units (inches) and Decimal units (feet). These templates can be found at: EAD_Standars\All Disciplines\Template\ The creation of all drawings will be accomplished by using one of the two templates provided with the EAD CAD Standard. By adhering to this process problems will be avoided when loading custom EAD linetypes. For a listing of which templates are typically used by each discipline refer to Table 6-I. Table 6-I
Architectural Units Architectural Electrical Mechanical Structural Decimal Units Civil Environmental Geotechnical Traffic

6.8.4

PAGE SETUPS

Page Setups enable the user to save specific settings within the AutoCAD plotting environment. The Page Setups created for the in-house designers make use of PC3, PMP and CTB files as well as configuration changes. PC3 files are typically copied to the Plotters folder under the root AutoCAD installation directory. The Page Setups created for in-house use are located on the internal network at: L:\EAD_Standards\All Disciplines\Page Setups\

6.9

PLOT SETUP

All drawings will be plotted from a paper space layout tab. The tab will be named the same as the sheet number being plotted. Full size and Half size sheets may be plotted from a single layout by utilizing page setups. Multiple layouts are not to be used for Full size and Half size sheets. Multiple layouts may be used for the plotting of multiple sequential sheets. Refer to Section 6.29 titled Appendix M Page Setups and Plotter Configurations for more information.

Last Updated: March 2010

Page 34

Engineering Department Manual


E/A Design Division CAD Standard

6.10

STAGE I CAD STANDARD

In an effort to streamline the CAD projects within the E/A Design Division a comprehensive CAD Standard has been developed. Although this standard was intended for use with projects that are at Stage II or beyond, many of the ideas are to be implemented during the Stage I effort. 6.10.1 STAGE I PROJECT DIRECTORY STRUCTURE The project directory structure, which resides on the M:\ drive and is described in Section 6.6 titled Project Directory Structure and File Naming Convention of this document will be maintained. 6.10.1.1 PROJECT IDENTIFIER NUMBER

A project identifier is assigned when the first charge code is developed. If a PID is available, a project folder with the PID will be created in the appropriate facility folder located on the M:\ drive. If a PID is not available, a project folder will be created within the Pre-Projects folder located on the M:\ drive. 6.10.1.2 FILE NAMING CONVENTION

If a PID is available, the project naming convention identified in Section 6.6.5 titled File Naming Convention will be maintained. If a PID is not available, a number generated by the CAD Support Group will temporarily substitute for the PID, until one is available. 6.10.1.3 LAYERING SCHEME

The layering scheme explained in Section 6.7.2 titled Layering Scheme Definition of this document will be maintained. The layer colors may be adjusted to suit the needs of any presentations being prepared. 6.10.1.4 ENTITY AND LAYER LINETYPES

Linetypes will be used as described in Section 6.7.3 titled Entity and Layer Linetypes of this document. If additional linetypes are created for illustration purposes, the linetype file must accompany the CAD file. The linetype file shall use the PID in the name. 6.10.1.5 ENTITY AND LAYER COLORS

All Entities and Layers will have their color assigned to bylayer. 6.10.1.6 SYMBOLOGY

The symbols provided with this standard will be used whenever possible. If a new symbol is created it will not have its colors assigned to byblock. To achieve multiple colors within a block, the creator will make use of multiple layers within the block definition. 6.10.1.7 TEXT STYLES AND HEIGHTS

It is understood that for presentation purposes a deviation from the standard text styles will occur. If third party fonts are used, those fonts must accompany the CAD file. Fonts that are not freely distributable or shareware are not to be used. 6.10.1.8 DIMENSION STYLES

If new dimension styles are created for presentation purposes, the names of the styles will be appropriate for the type of dimension being created. Also, all Text Styles created for use within the dimension style will have the prefix DIM_. Last Updated: March 2010 Page 35

Engineering Department Manual


E/A Design Division CAD Standard 6.10.2 STAGE I EXTERNAL REFERENCE FILES As stated in Section 6.7.9 titled External Reference Files of this standard, Overlays and Relative Paths are to be used. 6.10.2.1 PLOT SETUP

All drawings will be plotted from paper space layout tabs as described in Section 6.9 titled Plot Setup of this standard. The lead discipline is responsible for creating and making available page setups necessary for plotting. Further, any CTB files used other that those provided with this standard will accompany the CAD file. If used, the CTB created will have the PID prefixed to the file name. 6.10.2.2 PLAN SET PREPARATION

It is the responsibility of the lead discipline to prepare and distribute the border for the Stage I effort. Whenever possible the ANSI borders provided with this standard are to be used.

6.11

PLAN SET PREPARATION

6.11.1 PLAN SET TITLE SHEET The term Title Sheet refers to the top most sheet of the plan set. The Title Sheet border has undergone an extensive review by the CAD Committee. The use of block attributes will insure consistency between contracts and improve the appearance of all contract sets. It is important to maintain the integrity of the Title Sheet, therefore, the Title Sheet is never to be exploded. Illustrations of the Title Sheets can be found in Section 6.26 titled Appendix J Contract Borders and Title Sheets. 6.11.1.1 TITLE SHEET CONFIGURATION

The Title Sheet border drawing has purposely been created in paper space. As a result, this border drawing cannot be inserted as a block or externally referenced into other drawing files. The process for defining a Title Sheet is as follows. Begin by opening the Title_Sheet.dwg file located at: L:\EAD_Standards\All Disciplines\Contract Borders\ Once open Save the drawing to the appropriate project sub-folder. Enter the appropriate values for each attribute provided in the Title Sheet. 6.11.1.2 ENTERING TITLE SHEET INFORMATION

Each Title Sheet drawing file provided with the standard has three signature lines defined. They are: Deputy Director Engineering / Design Program Director XX or Sr. Program Manager / Program Manager Chief Engineer There are two possible options for the signature lines. Refer to Table 6-J to identify which option to use based on your contract type and cost and Table 6-K to determine which Layers are to be turned off for each option.

Last Updated: March 2010

Page 36

Engineering Department Manual


E/A Design Division CAD Standard Table 6-J
Contract Type Total Contract Cost Up to $1,000,000 M/WBE Contracts Above to $1,000,000 Title Sheet Signatures Required Deputy Director Engineering / Design Sr. Program Manager / Program Manager Deputy Director Engineering / Design Program Director Chief Engineer Deputy Director Engineering / Design Sr. Program Manager / Program Manager Deputy Director Engineering / Design Program Director Chief Engineer Option to Use Option 1

Option 2

Up to $2,500,000 Work Order Drawings and Standard Contracts Above to $2,500,000

Option 1

Option 2

Table 6-K
Layer Name GN-ANNO-TTLB-CHIF GN-ANNO-TTLB-PDIR GN-ANNO-TTLB-PMAN Status for Option 1 OFF OFF ON Status for Option 2 ON ON OFF

Under no circumstance will the Title Sheet border be exploded or modified. Figure 6-O shows the default Title Sheet provided with the EAD CAD Standard. The WORK ORDER No. line has been turned off by default and layer GN-ANNO-TTLB-WRKO is to be turned on if a WORK ORDER No. needs to be entered.

Figure 6-O Last Updated: March 2010 Page 37

Engineering Department Manual


E/A Design Division CAD Standard The PROGRAM DIRECTOR line contains an attribute, which by default is set to XX. The XX value is to be replaced with one of the following options: TB&T PORT COMMERCE AVIATION PATH / E&WD SECURITY Under the Contract Number the letters FAC are to be replaced with the appropriate Facility Code listed in Table 6-A and then followed by the Contract Number itself. Multiple stamps have been provided within the Title Sheet and are to be turned off when necessary. The stamps provided and the layers on which they are stored are show in Table 6-L. Table 6-L
Stamp FAA Law Review Preliminary Submission Layer Name GN-ANNO-TTLB-FAA GN-ANNO-STMP-LAWR GN-ANNO-STMP-PRLM GN-ANNO-STMP-SUBM

6.11.1.3

USING THE REVISION BLOCK WITHIN THE TITLE SHEET

A revision block named Drawing_Info Stamp_Revision.dwg has been provided with the EAD CAD Standard. When revisions are made this block is to be inserted using an endpoint snap to the upper left corner of the previous revision line. Figure 6-P displays where the revision stamp is to be inserted. The stamp is located on the network at: L:\EAD_Standards\All_Disciplines\Contract Borders\Stamps\ Once inserted the revision block will prompt the user for information pertaining to the revision. Under no circumstances will the revision block be exploded or modified.

6.11.1.4

PLOTTING THE TITLE SHEET

Figure 6-P

The layout for the Title Sheet will be configured to use one of the page setups supplied within this standard. As previously stated, outside consultants will need to configure the page setups for their own use and for the particular environment they are working in. After importing an appropriate page setup the Title Sheet will be configured to plot by layout and use the PA-MasterFull.ctb plot style. 6.11.2 PLAN SET PLOT SHEETS Plotsheet files are drawing files assembled as sheets for printing. These drawings consist only of external reference files. No linework is permitted within Plotsheet drawings in either Model or Paper space with the following exceptions: North Arrows Last Updated: March 2010 Page 38

Engineering Department Manual


E/A Design Division CAD Standard Scale Bars Revision Clouds and Revision Cloud Text Match Lines and Match Line Text View Titles Blocks with the prefix Drawing_Info In order to comply with this standard, each project will have a single Contract Border that will be created by the Lead Discipline and will be stored in that disciplines PUBLISH folder. All other disciplines will externally reference the border from the Lead Disciplines PUBLISH folder. This border will contain all information pertinent to the project itself. Once the Contract Border is properly referenced into each sheet the appropriate Drawing_Information block is to be inserted into each layout tab. The Drawing_Information block will contain all drawing specific information. Illustrations of the Contract Borders provided can be found in Section 6.26 titled Appendix J Contract Borders and Title Sheets. Outside consultants are required to reproduce the folder structure as specified in Section 6.6.4 titled Sample Project by copying the Sample Project and replacing the Facility name and PID with those of the current project. All backgrounds (including the Contract Border) provided by the E/A Design Division will go into their respective discipline folders. 6.11.2.1 CONFIGURING THE CONTRACT BORDER

To create the project border, open the Contract_Border.dwg file provided with this standard fill in all attribute information requested and save it to your disciplines PUBLISH folder with the name following the format described in Section 6.6.5.2 titled Contract Border File. As with the Title Sheet, the WORK ORDER No. line has been turned off by default and layer GN-ANNOTTLB-WRKO is to be turned on if a WORK ORDER No. needs to be entered. For a listing of Contract Border files that have been provided with this standard refer to Section 6.5.2 titled Distribution Files. 6.11.2.2 REFERENCING THE CONTRACT BORDER

To create a Plotsheet file, begin by externally referencing the Contract Border that was configured in the previous section. The border is to be referenced into a paper space layout, that has been configured following the steps outlined in Section 6.9 titled Plot Setup, with an insertion point of 0,0. Under no circumstances will the contract border be exploded, renamed or modified. 6.11.2.3 INSERTING THE DRAWING INFORMATION

Once the Contract Border has been externally referenced the Drawing_Info.dwg block will need to be inserted. This block will be inserted with an insertion point of 0,0 and all attribute information is to be filled out. The Drawing_Info.dwg block contains a pair of lines that state Original Signed By and Original Signee. These lines of text are stored on the layer GN-ANNO-TTLB-SIGN, which by default is turned off. The Original_Signee attribute field is to be filled in using the name of the person that signed the mylars. The layer this information is on is to be turned on when DWF files are created for any Stage of the drawings beyond signature. Figure 6-Q and Figure 6-R display this text OFF and ON. Note, this attribute is only required for internal use and outside consultants need not turn on this layer. For information on the correct process for outside consultants refer to Section 6.11.2.9 titled Using the Signature Stamps.

Last Updated: March 2010

Page 39

Engineering Department Manual


E/A Design Division CAD Standard

Figure 6-Q

Figure 6-R

When entering the Discipline Group and Discipline Sub-Group attribute fields users will need to refer to Table 6-M for the proper values to be used within these fields. Table 6-M
Discipline Group Architecture Landscape Civil Electrical Power Electronics Corrosion Protection Environmental General Geotechnical Mechanical Fire Protection HVAC Plumbing Structural Traffic Discipline Sub-Group

To promote consistency and easy identification of the people involved in the project the Designed By, Drawn By and Checked By attribute fields are to be filled out using the first initial, followed by a period and then the first ten characters of the last name. Note that a spaces before or after the period are not permitted. For Example: Filippo Brunelleschi would fill out the field as F.Brunellesc, truncating the last name at ten characters.

Last Updated: March 2010

Page 40

Engineering Department Manual


E/A Design Division CAD Standard 6.11.2.4 EDITING THE CONTRACT BORDER

The process used to create Contract Borders allows for flexibility in editing and updating information both at the project level as well as at the drawing level. If a project level change is required then the PIDCB.dwg file can be opened and modified and if a drawing level change is required then the individual drawing can be opened and modified. The benefit to working in this manner is that if a project level change is required only one drawing file needs to be edited and then the rest of the files will inherit the changes. 6.11.2.5 CREATING A VIEWPORT

Once the Contract Border has been externally referenced and the drawing information block has been inserted and filled out then a viewport must be created to display the drawing information that has been referenced into model space. When a viewport is created it is to be placed on the appropriate layer for that discipline, typically <discipline>-ANNO-VPRT. Once the viewport is created the zoom magnification or scale of the viewport must be set. All E/A Design Division files are created to be plotted with a scale of 1:1, which means that the viewports created will need to have a scale or magnification assigned to them. Once the viewport scale has been assigned and the drawing information has been centered within the view, the viewport display should be set to locked. 6.11.2.6 MAKING REVISIONS IN CONTRACT DRAWINGS

Two types of revisions can happen in a Contract Drawing Set, Partial Revisions and Complete Revisions. A partial revision is when only portions of the Contract Drawings have been changed and a complete revision is when a new Contract Drawing is created. Regardless of the revision type, users will required to place the Drawing_Info Stamp_Triangle.dwg block in the drawing pane, near the revised entities. A revision cloud is also to be placed around the area that is being revised. For Partial Revisions: A Revision Cloud will be placed either in Model Space or in Paper Space surrounding just the area of the drawing where changes were made. The Stamp Triangle will be placed right next to the Revision Cloud including the Revision Number. The Revision Block will be inserted including the Revision Number as well as the Date, the Description and the Initials of the person that approved the changes. For Complete Revisions: A Revision Cloud will be placed in Paper Space surrounding the entire drawing just outside the perimeter of the Contract Border. The Stamp Triangle will be placed in the lower right corner of the Plotsheet including the Revision Number. The Revision Block will be inserted including the Revision Number as well as the Date, the Description and the Initials of the person that approved the changes. For every Revision Triangle inserted into a Plotsheet a corresponding revision block is to be inserted within the border area as outlined in the following section.

Last Updated: March 2010

Page 41

Engineering Department Manual


E/A Design Division CAD Standard 6.11.2.7 USING THE REVISION BLOCK WITH THE CONTRACT BORDER

A revision block named Drawing_Info Stamp_Revision.dwg has been provided with the EAD CAD Standard. When revisions are made this block is to be inserted using an endpoint snap to the upper left corner of the previous revision line. Figure 6-S displays where the revision stamp is to be inserted. The stamp is located on the network at: L:\EAD_Standards\All_Disciplines\Contract Borders\Stamps\ Once inserted the revision block will prompt the user for information pertaining to the revision. Under no circumstances will the revision block be exploded or modified. Figure 6-S Submission stamps have been provided for both the Contract Border and Contract Border OS (oversize) sheets and can be found at: L:\EAD_Standards\All_Disciplines\Contract Borders\Stamps\ The submission stamps will be inserted as blocks within the Contract Border with an insertion point of 0,0. The following submission types have stamps provided with this standard: Law-Review Preliminary QA-Submission Percent Submission Figure 6-T displays how each of the four submission stamp types appear on the Contract Border. 6.11.2.8 USING THE SUBMISSION STAMPS

Figure 6-T

Last Updated: March 2010

Page 42

Engineering Department Manual


E/A Design Division CAD Standard 6.11.2.9 USING THE SIGNATURE STAMPS

Signature stamps have been provided for both the New York and New Jersey Professional Engineer and Registered Architect and are to be used by outside consultants in-lieu of Consultant Logos. The word Drawing_Info Stamp_ has been prefixed at the beginning of each stamp to indicate that these stamps are to be placed within the individual layout tabs and not directly into the Contract Border file. The signature stamps provided within this standard are located at: L:\EAD_Standards\All_Disciplines\Contract Borders\Stamps\ The use of the Signature stamps by outside consultants will require that the GN-ANNO-TTLB-PANU layer be turned off. This layer contains the signature lines for the in-house staff and is not needed when outside consultants are signing the sheets. Signature stamps are to be inserted with an insertion point of 0,0 and are required to have all appropriate attribute fields filled in. Note that when filling in the Consultant company information only the company name is to appear, not the address. If a sub-consultant is used then the primary consultant will fill in their company name using the Consultant1 and Consultant2 attribute fields and the sub-consultant will fill in their company name using the Sub-Consultant1 and Sub-Consultant2 attribute fields. On the left side of Figure 6-U the Contract Border with the GN-ANNO-TTLB-PANU layer for in-house use turned on is displayed and on the right side of Figure 6-U the Contract Border with that layer turned off and a signature stamp inserted is displayed.

Figure 6-U 6.11.2.10 USING THE CONFIDENTIAL AND PRIVILEGED STAMPS

Confidential and Privileged Stamps have been provided for both, the Contract Border and Contract Border - OS (oversize version). The word Drawing-Info - Stamp_ has been prefixed at the beginning of each Stamp to differentiate them from the Submission Stamps. The Confidential and Privileged Stamps are to be inserted as blocks with an insertion point of 0,0 on each individual sheet unless the entire project is considered Confidential and Privileged, in which case the stamps can be placed within the Contract Border. The Confidential and Privileged Stamps provided with this standard are located at: L:\EAD_Standards\All_Disciplines\Contract Borders\Stamps\ Figure 6-V illustrates a Contract Border with a Confidential and Privileged Stamp inserted.

Last Updated: March 2010

Page 43

Engineering Department Manual


E/A Design Division CAD Standard

Figure 6-V

6.12

SPECIAL PROJECTS

Special Projects are those in which unique circumstances may require different guidelines be followed in order to comply with the EAD CAD Standards. The contents of this section will be followed in addition to the ones already specified in previous sections, unless specifically instructed otherwise within this section. 6.12.1 CONFIDENTIAL AND PRIVILEGED PROJECTS Security projects contain Confidential and Privileged information and their access within the E/A Design Division network is restricted to certain users. For that reason, if the project being worked on is considered a Confidential and Privileged (CP) project a PLOTSHEETS_CP folder will be used to store all CP Plotsheet drawings.

Last Updated: March 2010

Page 44

Engineering Department Manual


E/A Design Division CAD Standard

6.13

CAD STANDARDS REVIEW REPORT

In an effort to improve the usage of the EAD CAD Standard, the CAD Support Group has developed a form called the CAD Standards Review Report, which allows for the rating of CAD Standards compliance on every project worked on by each discipline. CAD Standards reviews are applicable to all projects, inhouse and/or consultant that are issued either for construction contracts or work orders. 6.13.1 INTERIM CAD REVIEW Review is mandatory for: o o Contract drawings prepared by one discipline and sets consisting of more than 25 sheets. Contract drawings prepared by two or more disciplines and sets consisting of more than 15 sheets.

Requirements o o Timeframe: Required at 50% milestone or as determined by the LEA if no official interim milestone prior to the 100% submission Initiated by the LEA via EOL request form

Report is issued to the Assistant Chiefs, Principals, LEA and Task Leaders. 6.13.2 CONSTRUCTION CONTRACT PA WIDE CAD REVIEW Review is mandatory for all Contract Drawings o Initial failures are issued to the LEA and Task Leaders 3 weeks are provided for the correction of the files o o At the end of the 3 weeks a Report is issued to the Assistant Chiefs, Principals, LEA and Task Leaders At the Pre-Mylar Review Date reviews will be performed for any failing disciplines and the FINAL pass/fail Report will be issued. Drawings will not be reviewed after the Pre-Mylar Review Date Requirements o o Timeframe: Required at the on-set of PA Wide Review Initiated by the LEA via EOL request form Upon receipt of the request the CAD Support Group is to upload the files to Live Link for electronic review and notify the Contract Engineer of the initiation of PA Wide Review. Final Report is issued the Assistant Chiefs, Principals, LEA and Task Leaders 6.13.3 WORK ORDER CAD REVIEW Review is mandatory for: o o Mandatory for all Contract Drawings. Initial failures are issued to the LEA and Task Leaders 3 weeks are provided for the correction of the files Last Updated: March 2010 Page 45

Engineering Department Manual


E/A Design Division CAD Standard o At the end of the 3 weeks a Report is issued to the Assistant Chiefs, Principals, LEA and Task Leaders

Requirements o Initiated by the LEA via EOL request form Upon receipt of the request the CAD Support Group is to upload the files to Live Link for electronic review and notify the Contract Engineer of the initiation of PA Wide Review. Report is issued to the Assistant Chiefs, Principals, LEA and Task Leaders at the end of the 3 week period. The CAD Standards Review Report is divided into 3 section; the first section contains all the Mandatory Fields for which compliance with EAD CAD Standards is required in order for the project to pass, the second section contains all the Non-Mandatory Fields followed by a third section that includes notes and comments pertaining to the review. Items included within this Report are: Filename and Folder Structure o Project drawings and files referenced within them must be named according to the EAD CAD Standard and must be located within the sub-folders defined in this standard.

Plan Set Preparation o All External Referenced files and\or images shall be contained within the PID Folder Structure. The Title Sheet, Contract Border and Drawing Information block along with the Professional Stamps provided within the EAD CAD Standard shall be used without any modifications and/or alterations.

CAD Practice o The layers provided within the EAD CAD Standard must be used in all drawing files. These layers are pre-configured to work in conjunction with each disciplines pen settings (CTB). All External Referenced files and\or images shall be set as Overlay and Relative Pathing.

Plot Setup o Drawings must be prepared using the PA-MasterFull.ctb file (pen settings). This will ensure consistency of plotting drawings from any workstation within Engineering.

Submittals Information o DWF files are required at each submittal. They are to be created in full size, multi-sheet and grouped together by Plotsheet Type and Series (if used).

Land Desktop Projects (Civil Only) o Data files for Land Desktop projects must be available for archiving. The Land Desktop project is essential for linking data to drawing objects.

This form will be reviewed on a regular basis and is subject to changes. If a change is approved, it will be posted on the E/A Design Division CAD Standard website http://www.panynj-cadstandards.com/ and incorporated into the next revision of this document. The following two pages illustrate the first two sections of the CAD Standards Review Report and are to be used as a checklist for checking CAD Standard compliance prior to submitting drawings.

Last Updated: March 2010

Page 46

Engineering Department Manual


E/A Design Division CAD Standard

Mandatory Items

Last Updated: March 2010

Page 47

Engineering Department Manual


E/A Design Division CAD Standard

Non Mandatory Items

Last Updated: March 2010

Page 48

Engineering Department Manual


E/A Design Division CAD Standard

6.14

UPDATE AND REVISION PROCEDURES

The dynamic nature of CAD technology and the engineering process dictates that this document will change over time. Changes to this document will be made by following strict procedures and guidelines. Changes may be made based on errors and omissions, as well as to enhance or update the standards based on changes in the CAD environment. All requested changes to this document must be accompanied by a Request to Change Standards form provided in Section 6.28 titled Appendix L Request to Change Standard. The Request to Change Standards form must be provided to the CAD Support Group. All Request to Change Standards forms will be reviewed on a periodic basis. If the change is approved, it will be incorporated into the next draft of this document and all support files will be modified. Updates to this document and the related support files will be made as required. Updates will be posted on http://www.panynj-cadstandards.com/

6.15

CONTACT AND SUPPORT INFORMATION

Questions regarding the standards provided within this document should be directed to the CAD Support Group at: 973-565-7510 or engcadd@panynj.gov

6.16

CONCLUSION

This document is a comprehensive standard for the creation of contract drawings for the PANYNJ, E/A Design Division. All drawings submitted to the E/A Design Division must adhere to the conventions documented here. The CAD Support Group will use automated procedures to verify compliance with this standard.

Last Updated: March 2010

Page 49

Engineering Department Manual


E/A Design Division CAD Standard

6.17

APPENDIX A ARCHITECTURAL DISCIPLINE

6.17.1 CONTENT PREFERENCES

Last Updated: March 2010

Page 50

Engineering Department Manual


E/A Design Division CAD Standard 6.17.2 LAYER STRATAGEM 6.17.2.1
Discipline Minor Major

ARCHITECTURAL NEW WORK


Linetype Phase Color Plots Desc

Description

Annotation A ANNO A ANNO A ANNO A ANNO A ANNO A ANNO A ANNO A ANNO A ANNO A ANNO A ANNO A ANNO A ANNO A ANNO A ANNO A ANNO A ANNO A ANNO A ANNO A ANNO A ANNO A ANNO A ANNO A ANNO A A A A A A A A A A A A A A A A A ANNO ANNO ANNO ANNO ANNO ANNO ANNO ANNO ANNO ANNO ANNO ANNO ANNO ANNO ANNO ANNO ANNO

_BUS BREK CARS CHNG CLIN COLS COLS DETL DIMS DIMS ELEV ELEV ELEV IDEN IDEN IDEN IDEN IDEN IDEN IDEN IDEN LGND LGND MLIN NOTE PEOP REDL SCUT SYMB SYMB SYMB SYMB SYMB SYMB TEXT TEXT TEXT TEXT TEXT TEXT TEXT

BUBL CLIN BUBL GUID FFLR GUID VERT DETL DOOR ELEV FURN GLAZ ROOM SCUT WALL DISC

5 5 8 51 8 4 8 255 1 5 1 1 1 3 1 3 1 1 1 3 1 212 1 4 212 8 10 212 5 3 200 5 1 212 212 1 5 212 5 5 5

Continuous Continuous Continuous DIVIDE4 CENTER5 Continuous CENTER5 DASHED5 Continuous DOT8 Continuous DOT8 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous DIVIDE2 Continuous Continuous Continuous DOT8 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous

Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

GUID AROW MISC NPLT NRTH SCLE TEXT _CLL DATE ELEV LEDR MISC MLIN

Buses Break Line Cars Identification Of Updated Work General Plan/Elevation/Section Centerline Column Centerline Identification Column Centerline Extension Used With Notes Detail Bubble Outline (Indicate Blow-Up Or Detail) Dimensions Dimension Guide Line Spot Elevation Symbol (Or Block Insertion Layer) Vertical Elevation Symbol Line Vertical Elevation Symbol On Section/Elevation Detail Symbol And Extension Line To Bubble Door Number Symbol; Hardware Group Etc. Elevation Symbol (Or Block Insertion Layer) Furniture Identification Symbol Window Number Symbol Block Insertion Layer Room Identification (Shown As A Block) Section Cut Symbol (Or Block Insertion Layer) Partition Type Identification Symbol Legends And Symbols Associated With Legends Legend Disclaimer Match Line Blocks Of Miscellaneous Notes; Boiler Plate Notes And Frames People, Pedestrians Etc. Redline Section Cut Line Connecting Section Head And Tail Directional Arrow Miscellaneous Symbols Miscellaneous Symbols- Not Plotted North Arrow Scale Bar Text In Symbol Blocks Text (Generated By Leader; Quick Leader Or Multi-Leader) Contract Limit Line Text Presentation Date Elevation Symbol Text Text Leader Line (If Drawn Separately) Secondary Text Match Line Text

Last Updated: March 2010

Page 51

Engineering Department Manual


E/A Design Division CAD Standard
Discipline Linetype

Phase

Minor

Major

Color

Plots

Desc

Description

A A A A A A A A Area A

ANNO ANNO ANNO ANNO ANNO ANNO ANNO ANNO AREA

TEXT TEXT TEXT TRAN TRUK TTLB TTLB VPRT OTLN TEXT

PROP ROWL STRE

PRES

1 212 8 8 8 51 5 200 255 212 212 5 1 1 5 1 1 8 1 5 212 1 1 51 3 5 8 5 8 8 8 51 1 212 5 5 3 5 212 212 212 1

Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous DASHED4 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous DASHED5 Continuous Continuous Continuous Continuous Continuous Continuous Continuous HIDDEN4 Continuous Continuous Continuous DASHED5 CENTER5 Continuous Continuous Continuous HIDDEN4 Continuous Continuous Continuous Continuous Continuous Continuous Continuous

Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

Property Line Text Right Of Way Text Street Name Text Trains, Subways & Monorails Trucks Drawing Title With Scale Bar Drawing Title On Presentation Border View Port Area Calculation Boundary Lines Area Calculation, Room Number, Tenant Identification Numbers (Shown As Text) Ceiling Grid - Tile Pattern Steel Beam In Rcp Plans Light Fixtures Or Block Insertion Layer Ceiling/Roof Penetrations Overhang Out-Line Shown On Reflected Ceiling Plan (Only) Return Air Diffusers Supply Diffusers Shaft Penetrations Overhead General Overhead Signage Skylight Out-Line Shown On Reflected Ceiling Plan (Only) Ceiling Soffit Edges Speaker Sprinkler Columns Or Block Insertion Layer Structural Steel For Columns Or Block Insertion Layer Structural Steel Elements Hidden Architectural Steel Columns In Stair Column Base Plate Structural Beam Elements Or Block Insertion Layer Structural Beam Elements Above Structural Column Centerline Concrete Columns Column Detail Column Enclosure Hidden Column Elements Miscellaneous Columns Elements Precast Concrete Columns Column Piles Full Height Door Or Block Insertion Layer Door Headers (Appear On Reflected Ceiling Plan (Only)S) Door Jamb Partial Height Door; Swing And Leaf

A AREA Ceiling A CLNG A CLNG A CLNG A CLNG A CLNG A CLNG A CLNG A CLNG A CLNG A CLNG A CLNG A CLNG A CLNG Column A COLS A COLS A COLS A COLS A COLS A COLS A COLS A COLS A COLS A COLS A COLS A COLS A COLS A COLS A COLS Door A DOOR A DOOR A DOOR A DOOR

BEAM LGHT OPNG OVHG RDFF SDFF SHFT SIGN SKLT SOFF SPKR SPRN

OVHD

_STL _STL _STL BASE BEAM BEAM CLIN CONC DETL ENCL HIDN MISC PCST PILE

HIDN STRS PLAT ABVE

HEAD JAMB PRHT

Last Updated: March 2010

Page 52

Engineering Department Manual


E/A Design Division CAD Standard
Discipline Linetype

Phase

Minor

Major

Color

Plots

Desc

Description

A DOOR Elevation A ELEV A ELEV A ELEV A ELEV A ELEV A ELEV A ELEV A ELEV A ELEV A ELEV A ELEV A ELEV A ELEV A ELEV A ELEV A ELEV A ELEV A ELEV A ELEV A ELEV A ELEV A ELEV A ELEV A ELEV A ELEV A ELEV A ELEV A ELEV A ELEV A ELEV A ELEV A ELEV A ELEV A ELEV A ELEV A ELEV A ELEV A ELEV A ELEV A ELEV A ELEV A ELEV A ELEV A ELEV A ELEV

SWNG _STL _STL BALC BLDG BOLL BYND CNPY COLS COLS COLS COLS COLS COLS CURB DECK DOOR DOOR EQPM ESCL ESCL ESCL ESCL ESCL EVTR EVTR EVTR FASA FENC FGPN FURN FURN GLAZ GLAZ GRAL GRAL HRAL HRAL LGHT LGHT LUVR MECH MECH MECH RAMP RAMP

5 212 5 1 253 8 1 1 5 1 8 212 212 5 8 1 5 8 212 8 253 8 8 8 5 251 8 1 1 5 5 5 1 8 5 8 5 8 5 5 5 5 5 1 5 8

DASHED4 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous DASHED4 Continuous Continuous Continuous Continuous Continuous Continuous Continuous DASHED5 DOT5 DASHED5 Continuous Continuous DOT5 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous DASHED4

Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

Door Swing (Only When Drawn As Linework) Steel Columns Elevation Steel Flange/Web In Elevation Elevation Of Balcony Elements Building Elevations In The Distance Security Bollard Elevation Materials Beyond Canopy Elevations Elevation Of Column Elements Architectural Steel Column Elevation Elevation Of Columns In The Distance Elevation Of Concrete Columns Column Enclosure Elevation Elevation Of Hidden Column Elements Curb Elevation Metal Deck In Elevation Door Elevation Door Elevation In The Distance Elevations Of Equipment Escalator Elevation Escalator Elevation In The Distance Escalator And Equipment Elevations Escalator Elevation Hidden Escalator Machinery Elevations (Non-Equipment) Elevator Elevation Elevator Elevation In The Distance Elevator Elevation Hidden Fascia Elevation Architectural Fence Elevation Fiberglass Wall Panels/Joints In Elevation Elevation Of Furniture Security Planter Elevation Window And/Or Glass Elevation Window Mullion Elevation Guardrail Elevation Guardrail Elevation In The Distance Handrail Elevation Handrail Elevation In The Distance Elevation Ceiling Mounted Light Fixture Elevation Wall Mounted Light Fixture Louvers In Elevation Elevation Of Mechanical Duct Elevation Of Miscellaneous Mechanical Elements Elevation Of Mechanical Registers Ramp Elevation In The Distance Ramp Elevation Hidden

DETL BYND

_STL BYND CONC ENCL HIDN

BYND

BYND EQPM HIDN MACH BYND HIDN

PLNT MULL BYND BYND CLNG SCON DUCT MISC REGI BYND HIDN

Last Updated: March 2010

Page 53

Engineering Department Manual


E/A Design Division CAD Standard
Discipline Linetype

Phase

Minor

Major

Color

Plots

Desc

Description

A ELEV A ELEV A ELEV A ELEV A ELEV A ELEV A ELEV A ELEV A ELEV A ELEV A ELEV A ELEV A ELEV A ELEV A ELEV A ELEV A ELEV A ELEV Equipment A EQPM A EQPM A EQPM A EQPM A EQPM A EQPM A EQPM A EQPM A EQPM A EQPM A EQPM A EQPM A EQPM A EQPM Escalator A ESCL A ESCL A ESCL A ESCL A ESCL A ESCL A ESCL A ESCL A ESCL Elevator A EVTR A EVTR A EVTR

ROOF ROOF ROOF ROOF SECU STRS STRS STRS STRS SWAL SWAL SWAL VENT WALL WALL WALL WALL WALL

BYND GUTR HIDN

GRAL HIDN HRAL MISC TBAK

BHND BYND HIDN MISC

212 253 251 8 8 8 8 253 8 1 8 8 212 3 5 8 8 1 212 5 251 5 51 1 5 8 1 212 5 5 212 212 1 8 8 1 5 8 8 1 255 212 8 3

Continuous Continuous Continuous HIDDEN4 Continuous Continuous Continuous DASHED4 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous HIDDEN4 Continuous Continuous Continuous DOT2 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous DASHED4 Continuous Continuous Continuous DASHED5 DOT4 Continuous Continuous Continuous DASHED5 Continuous Continuous Continuous Continuous Continuous

Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No Yes Yes Yes

Roof Elevation Elements Of Roof Elevations In The Distance Gutter And Leader - Beyond Hidden Roof Elements Elevation Security Elements Elevation Stair Elevation Stair Guardrail Elevation Stair Elevation Hidden Stair Handrail Elevation Slurry Wall Elevation Slurry Wall Elevation Miscellaneous Slurry Wall Tieback Elevation Vent Elevation Wall Outline/Perimeter Wall Elements Elevation Behind Wall Elements Elevation In The Distance Elements Behind Wall Plane Wall Elevation Equipment Block Insertion Layer Trash Compactor Trash Compactor Below Conveyor Belt Cogeneration Plant Fire Hose Cabinet Lavatories, Toilets, Urinals Car Lift Machines Mechanical Duct Equipment Air Conditioner/ Heating Unit Miscellaneous Equipment Equipment Not In Contract Substation Equipment Mechanical Vent Escalator Block Insertion Layer Escalator Above (Or Block Insertion Layer) Escalator Below (Or Block Insertion Layer) Escalator Body Outline Escalator Handrail Handrail Infill Panel Glass, Metal, Etc. Escalator Machinery Hidden Escalator Treads Escalator Working Points Elevator Block Insertion Layer Elevator Cab Elevator Structural Steel

CMPK CMPK CNVY COGN FHCB FIXT LIFT MECH MECH MISC NICN SSTA VENT

BLOW

DUCT HVAC

ABVE BLOW ENCL HRAL HRAL MACH STRS WPNT

PANL HIDN NPLT

_CAB _STL

Last Updated: March 2010

Page 54

Engineering Department Manual


E/A Design Division CAD Standard
Discipline Linetype

Phase

Minor

Major

Color

Plots

Desc

Description

A EVTR A EVTR A EVTR A EVTR A EVTR A EVTR A EVTR A EVTR A EVTR A EVTR A EVTR A EVTR A EVTR A EVTR A EVTR A EVTR A EVTR A EVTR A EVTR A EVTR A EVTR A EVTR A EVTR A EVTR A EVTR A EVTR Floor Plan A FLOR A FLOR A FLOR A FLOR A FLOR A FLOR A FLOR A FLOR A FLOR A FLOR A FLOR A FLOR A FLOR A FLOR A FLOR A FLOR A FLOR A FLOR A FLOR A FLOR

_STL _STL _STL BOLS CALL CNWT CROS DOOR DOOR ENCL EQPM GLAZ HIDN HRAL HWAY HYDR LUVR MISC PANL PLFM SECU SHFT SHRD SILL SPKR STIL

PLAT POST RODS CHNL KIOS

MISC

EQPM CYLR

CMRA

1 1 1 1 5 5 51 1 5 212 1 5 8 5 8 51 8 1 8 1 1 1 5 212 1 5 3 1 212 1 5 1 5 1 1 5 1 5 1 1 1 5 5 1 1 3

Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous HIDDEN4 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous DASHED5 Continuous Continuous DASHEDX2 Continuous Continuous DOT2 Continuous Continuous Continuous Continuous Continuous HIDDEN5 Continuous HIDDEN4 DASHED4 Continuous Continuous Continuous

Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

Elevator Steel Plate Elevator Steel Posts Elevator Steel Rods Elevator Bolster Channels Elevator Call Kiosk Elevator Counter Weights Elevator Cab Crosshead Elevator Door Miscellaneous Door Elements Elevator Enclosure Elevator Equipment Elevator Glass Hidden Elevator Elements Elevator Handrail Elevator Hoist Way Equipment Elevator Hydraulic Cylinder Elevator Vent Louvers Miscellaneous Elevator Related Elements Elevator Operating Panel Elevator Platform Elevator Security Camera Elevator Shaft Elevator Shroud Elevator Sill/Threshold Elevator Handsfree Speaker Phone Elevator Stiles Edge Of Slab: At Floor Opening, Outline Of Floor Floor Outline Above Floor Beam Floor Beam Below Floor Outline Below Casework (Manufactured Cabinets) Loading Dock Loading Dock Below Interior Decorative Fence Guardrails Not Attached To Stairs Handrails Not Attached To Stairs Handrails Below X Representing Floor Opening (Excluding Shafts) Floor Opening Above Floor Open To Below Overhead Items (Shelves, Etc.) Overhang Out-Line Shown On Floor Plan Platform Platform Edge Extension Of Platform Floor

ABVE BEAM BEAM BLOW CASE DOCK DOCK FENC GRAL HRAL HRAL OPNG OPNG OPNG OVHD OVHG PLFM PLFM PLFM

BLOW

BLOW ARCH

BLOW ABVE BLOW

EDGE EXTN

Last Updated: March 2010

Page 55

Engineering Department Manual


E/A Design Division CAD Standard
Discipline Linetype

Phase

Minor

Major

Color

Plots

Desc

Description

A A A A A A A A A A A A A A A A A A A A A A

FLOR FLOR FLOR FLOR FLOR FLOR FLOR FLOR FLOR FLOR FLOR FLOR FLOR FLOR FLOR FLOR FLOR FLOR FLOR FLOR FLOR FLOR

RAIS RAMP RAMP SCOR SCOR SECU SLAB SLAB SLAB SPCL STRS STRS STRS STRS STRS STRS STRS STRS STRS STRS TACT TPTN WDWK ABVE MAJR MINR

212 5 5 3 5 1 3 1 5 5 1 1 8 8 8 8 8 8 253 8 1 212 212 1 1 212 1 212 1 1 8 1 1 212 212 5 5 212 1 1 5 212 5

BLOW BYND

ABVE BEAM BLOW GRAL HIDN HRAL LADR MISC STRG

Continuous Continuous HIDDEN3_TO_3 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous DASHED2 Continuous DOT2 Continuous HIDDEN2 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous

Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

Raised Floors Ramp Ramp Above Control And/Or Expansion Joints Tooled Joints Security Floor Slab Edge Floor Slab Edge Below Floor Slab Edge Beyond (Viewed From Opening Above) Arch. Specialties (Toilet Room Access. Display Cases) Stairs Or Block Insertion Layer Stairs Above Stairs Beam Stairs Below Stairs Guardrail Stairs Hidden (Stair Structure Etc.) Stairs Handrail Ladder Stairs Miscellaneous Stair Stringer Tactile Strip Toilet Partitions Woodwork (Field - Built Cabinets & Counters - Usually Dash) Furniture - Desks, Etc. Chair And Other Seating Counters Heat Sink Info Kiosk Furniture Panels, Storage Components, Etc. Passimeter Reader Planter Ticket Vending Machines Turnstiles Windows,Window Walls,Glazed Partitions Curtain Walls Glass Door, Glass Pane Glazing Hardware Window Mullions Window Mullions Miscellaneous Partial Height Glazed Surface Windows Sill Exterior Windows Sill Interior Skylight Out-Line Shown On Floor Plan

A FLOR Furniture A FURN A FURN A FURN A FURN A FURN A FURN A FURN A FURN A FURN A FURN Glazing A GLAZ A GLAZ A GLAZ A GLAZ A GLAZ A GLAZ A GLAZ A GLAZ A GLAZ A GLAZ Graphics

CHAR CNTR HEAT KIOS MISC PASM PLTR TKVM TURN

CURT DOOR HDWR MULL MULL PRHT SILL SILL SKLT

MISC EXTR INTR

Last Updated: March 2010

Page 56

Engineering Department Manual


E/A Design Division CAD Standard
Discipline Linetype

Phase

Minor

Major

Color

Plots

Desc

Description

A GRPH A GRPH A GRPH A GRPH Key Plan A KPLN A KPLN A KPLN A KPLN A KPLN A KPLN A KPLN A KPLN A KPLN Patterns A PATT A PATT A PATT A PATT A PATT A PATT A PATT A PATT A PATT A PATT A PATT A PATT A PATT A PATT A PATT A PATT A PATT A PATT A PATT A PATT A PATT Reference A REFN A REFN A REFN A REFN A REFN A REFN A REFN A REFN A REFN A REFN

3DEE IMAG IMAG IMAG

RENR SIGN

5 255 255 255 212 8 1 251 252 1 1 8 1 8 251 8 8 8 8 8 251 8 8 8 8 8 8 8 8 8 8 8 251 251 113 85 85 75 200 15 85 211 21 252

Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous HIDDEN4 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous PHANTOM4 Continuous HIDDEN CENTER5 Continuous Continuous Continuous Continuous CENTER5 Continuous

Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

3d Images Graphic Images I.E. (Billboards & Advertisements) Rendering And Watercolor Images Graphic Signage (Full Color - Using Pantone Colors) Key Plans Turnstiles In Key Plan Key Plan Miscellaneous Low Roof In Key Plan Roof Miscellaneous In Key Plan Text In Key Plan Main Walls In Key Plan Hidden Walls In Key Plan Miscellaneous Walls In Key Plan Textures Concrete Masonry Unit Textures Primary Steel Textures Miscellaneous, Steel, Metal Textures Area Cross Hatching, Miscellaneous Patterning, Poche Ceiling Textures Column Pattern Concrete Textures Fiberglass Textures Pavings, Tile, Carpet Patterns, Material Pattern Finish Patterns Grout Fill Textures Gypsum / Drywall Textures Foam Insulation Board Textures Batten Insulation Textures Miscellaneous Textures Protection Board Textures Roof Surface Patterns, Hatching Material Patterning, Wall Insulation, Hatching And Fill Concrete Wall Patterns Wood Pattern Reference Axial Alignment Reference Area Outline For Area Calculations Not Printed Reference Building Line Reference Centerline Reference Column Bubbles And/Or Identification Reference Dimensions Any Lines Used To Construct Escalators Reference Sheet Edge And Available Drawing Area Reference Grid For Details And/Or Drawing Layout Horizontal Construction Lines

FURN MISC ROOF ROOF TEXT WALL WALL WALL

TURN LOWR MISC

HIDN MISC

_CMU _STL _STL AREA CLNG COLS CONC FGPN FLOR FURN GROT GYBD INSU INSU MISC PROT ROOF WALL WALL WOOD ALGN AREA BLDG CLIN COLS DIMS ESCL FRME GRID GUID

MISC

BATT

CONC

AXIS OTLN LINE BUBL

HORZ

Last Updated: March 2010

Page 57

Engineering Department Manual


E/A Design Division CAD Standard
Discipline Linetype

Phase

Minor

Major

Color

Plots

Desc

Description

A A A A A A A A A A A A

REFN REFN REFN REFN REFN REFN REFN REFN REFN REFN REFN REFN

GUID GUID KPLN NSRT STRS TEXT TEXT TEXT TEXT TRAK VPRT WPNT BUBL SYMB

LINE VERT BLOK

ESCL EVTR VCIR DYNA FRME

151 143 201 255 15 15 222 222 15 93 1 255 4 3 4 212 8 51 1 8 1 5 8 3 5 212 1 8 1 8 8 8 8 212 255 51 8 5 4 212 212 1

Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous DASHED5 Continuous Continuous Continuous Continuous Continuous DASHED4 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous HIDDEN HIDDEN Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous

Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

A REVS A REVS Roof A ROOF A ROOF A ROOF A ROOF A ROOF A ROOF A ROOF A ROOF A ROOF A ROOF A ROOF A ROOF A ROOF A ROOF A ROOF A ROOF A ROOF A ROOF A ROOF Room A ROOM Schedule A SCHD Sections A SECT A SECT A SECT A SECT A SECT A SECT A SECT

0001 0001

General Construction Lines Vertical Construction Lines Reference Key Plan Fixed Block Insertion Point Any Lines Use To Construct Stairs Reference Text Reference Text For Escalator Design Reference Text For Elevators Design Reference Text For Stair Design Reference Track Dynamic Envelope Polygon Representing The View Port Window Area Drawn In Model Space General Working Points Revision Cloud And Arc (Change Number With Each Revision) Revision Triangle (Change Number With Each Revision) Roof Outline, Roof Perimeter / Edge, Roof Geometry Roof Above Outline Roof Below Canopy Geometry - Main Canopy Geometry Secondary Roof Drain Roof Outline Gutter And Leader Gutter And Leader - Below High Roof View From The Top Level Changes, Pitch Directions And Cants Low Roof Stair Riser, Stair Handrail, Nosing, Guard Rail, Roof Furn. Roof Surface Patterns, Hatching Roof Parapet Roof Parapet Below Hidden Roof Ribs Roof Stairs Above Roof Stairs Drain Room Name (Shown As Text) Schedule Insertion Layer (Shown As Autocad Table) Structural Steel Cut By Section Section Through Miscellaneous Steel Shapes And Column Section Of Steel Column Section Of Concrete Beam Section Of Light Fixture In Ceiling Section Of Ceiling Panel Canopy In Section

ABVE BLOW CNPY CNPY DRAN EDGE GUTR GUTR HIGH LEVL LOWR MISC PATT PPET PPET RIBS STRS STRS NAME TABL _STL _STL BEAM BEAM CLNG CLNG CNPY

MISC

BLOW

BLOW HIDN ABVE DRAN

MISC _STL CONC LGHT PANL

Last Updated: March 2010

Page 58

Engineering Department Manual


E/A Design Division CAD Standard
Discipline Linetype

Phase

Minor

Major

Color

Plots

Desc

Description

A A A A A A A A A A A A A A A A A A A A A A A A A A A

SECT SECT SECT SECT SECT SECT SECT SECT SECT SECT SECT SECT SECT SECT SECT SECT SECT SECT SECT SECT SECT SECT SECT SECT SECT SECT SECT

COLS COLS COLS COLS COLS COLS COLS CONC CONC DECK DOOR DUCT DUCT DUCT ESCL ESCL ESCL FNDA GLAZ GLAZ GRAL HRAL JBAR MCUT MCUT MCUT MISC MISC PANL PIPE PIPE RAMP RIVR SEWR SKLT STRS STRS TRAN WALL WALL WALL WALL WALL WALL WDBL

_STL CONC DETL ENCL HDWR HIDN PCST MISC

51 51 1 212 5 8 8 51 5 212 1 8 212 3 3 5 3 51 3 1 5 5 51 51 1 1 3 1 212 1 5 3 1 3 5 3 3 5 4 212 1 212 3 3 5

Continuous Continuous Continuous Continuous Continuous DASHED4 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous DASHED5 Continuous Continuous HIDDEN3_TO_3 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous

Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

MISC RETN SUPL HRAL MACH

HDWR

HIDN MISC

Steel Column Section Section Of Concrete Column Column Section Detail Column Enclosure Section Elements Associated With Securing Columns To Other Elements Like Nuts, Bolts, Screws, Etc. Hidden Column Section Section Of Precast Concrete Section Of Concrete Section Of Miscellaneous Concrete Metal Deck In Section Door In Section Section Thru Miscellaneous Mechanical Section Thru Mechanical Return Duct Section Thru Mechanical Supply Duct Escalator In Section Escalator Handrail In Section Escalator Machinery In Section Foundations In Section Windows Cut By Section Section Of Glazing Hardware Guardrail Section Section Of Handrail Section Of Jersey Barrier Main Material Cut By Section Section Of Hidden Material Secondary Material Cut In Section Miscellaneous Material Cut By Section Hidden Miscellaneous Material Cut In Section Section Of Stone Panel Section Thru Pipe Section Thru Miscellaneous Pipe Elements Section Of Ramp River Line In Section Sewer In Section Skylight Section Stairs In Section Section Of Stair Stringer Section Of Trains, Subways & Monorails Walls Cut By Section Fiber Glass Panel And/Or System In Section Gypsum Wall Board In Section Miscellaneous Wall Section Retaining Wall In Section Shaft Wall In Section Wood Blocking In Section

A SECT A SECT A SECT A SECT A SECT A SECT A SECT A SECT A SECT A SECT A SECT A SECT A SECT A SECT A SECT A SECT A SECT A SECT Site Plan

HIDN STNE MISC

STRG

FGPN GYPB MISC RETN SHFT

Last Updated: March 2010

Page 59

Engineering Department Manual


E/A Design Division CAD Standard
Discipline Linetype

Phase

Minor

Major

Color

Plots

Desc

Description

A A A A A A A A A A A A A A A A A A

SITE SITE SITE SITE SITE SITE SITE SITE SITE SITE SITE SITE SITE SITE SITE SITE SITE SITE

AIRP ALGN ALGN ALGN BLDG BOLL CURB FENC FENC GRID GRID GRID GRID JBAR LGHT MISC PILE SIGN STRE STRE SWLK TBAK TRAF TRAK TRAK TUNL UNGR UNGR

_CLL PROP ROWL ABVE

ARCH HZ01 HZ02 VT01 VT02

3 4 1 3 3 5 5 1 1 8 5 8 5 5 5 8 3 1 5 8 5 252 8 5 1 8 251 251 51 8

A SITE A SITE A SITE A SITE A SITE A SITE A SITE A SITE A SITE A SITE Slurry Wall A SWAL A SWAL Tone A A A A A A A A A A A A A A TONE TONE TONE TONE TONE TONE TONE TONE TONE TONE TONE TONE TONE TONE

SBAK STRP

SLPE CLIN STRU UTIL

Continuous PHANTOM4 DASHDOT4 PHANTOM5 DASHEDX2 Continuous Continuous Continuous Continuous Continuous DOT4 Continuous DOT4 Continuous Continuous Continuous Continuous Continuous HIDDEN3_TO_3 Continuous Continuous Continuous DASHED5 Continuous CENTER Continuous Continuous Continuous Continuous Continuous

Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

Airport Contract Limit Line Property Line Right Of Way Line Building Above Outline Security Bollard Curbs Exterior Fence Exterior Decorative Fence Primary X-Axis Coordinate Grid Secondary X-Axis Coordinate Grid Primary Y-Axis Coordinate Grid Secondary Y-Axis Coordinate Grid Jersey Barrier Street Light Miscellaneous Site Features Piles Site Signage Street Setbacks Traffic Street Striping Sidewalk Tiebacks Slope Tracks Track Centerlines Tunnel Underground Structure Or Xref/Block Insertion Layer Underground Utilities Or Xref/Block Insertion Layer Slurry Wall Slurry Wall Tieback Various Color Toning (Used For Presentation - Stage 1 Only) Sky Zone Fill Shading Of Airport Building Sections And Elevations Column Enclosure Fill Section/Elevation/Plan Ground Plane Mechanical Zone Fill Office Zone Fill Open To Below Zone Fill Outline Of Tone Fill Sky Fill Outline Building Sections And Elevations Outline Column Enclosure Fill Outline Section/Elevation/Plan Ground Plane Outline

TBAK

_SKY AIRP BLDG COLS GRND MECH OFCE OPNG OTLN OTLN OTLN OTLN OTLN

_SKY BLDG COLS GRND

250 61 251 191 253 251 153 41 61 165 61 191 253 251

Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous

Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

Last Updated: March 2010

Page 60

Engineering Department Manual


E/A Design Division CAD Standard
Discipline Linetype

Phase

Minor

Major

Color

Plots

Desc

Description

A A A A A A A A A A A A A A A A A A Wall A A A A A A A A A A A A A A A A A A A A A A A A A A Xref

TONE TONE TONE TONE TONE TONE TONE TONE TONE TONE TONE TONE TONE TONE TONE TONE TONE TONE WALL WALL WALL WALL WALL WALL WALL WALL WALL WALL WALL WALL WALL WALL WALL WALL WALL WALL WALL WALL WALL WALL WALL WALL WALL WALL

OTLN OTLN OTLN OTLN OTLN OTLN OTLN OTLN OTLN OTLN OTLN PARK PUBL RETL RIVR SERV SWAL VCIR

MECH OFCE OPNG PARK PUBL RETL RIVR SECT SERV SWAL VCIR

153 41 61 254 40 21 153 255 141 253 30 254 40 21 153 141 253 30 4 5 1 5 5 212 1 5 1 1 8 1 1 4 4 3 1 3 3 3

Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous DASHEDX2 Continuous DASHED5 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous DASHED2 DASHDOT Continuous Continuous Continuous Continuous Continuous Continuous Continuous HIDDEN Continuous

Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

Mechanical Fill Outline Office Fill Outline Open To Below Fill Outline Parking Fill Outline Public Fill Outline Retail Fill Outline River Fill Outline Shading Outlines Service Fill Outline Slurry Wall Outline Vertical Circulation Fill Outline Parking Zone Fill Public Zone Fill Retail Zone Fill River Zone Fill Service Zone Fill Shading Of Slurry Walls Vertical Circulation Zone Fill Full Height Walls, Stair And Shaft Walls, Walls To Structure Wall Above Wall Barrier Or Liner Wall Wall Below Booth Wall Wall Mounted Casework Canopy Wall Fiberglass Wall Panel Finishes, Woodwork, Trim Gypsum Wallboard Kalwall Infill Grid Kalwall Main Panel Miscellaneous Wall Movable Partitions Building Outlines Outline Of Wall Above Outline Of Wall Below Partial Height Walls (Dont Appear On Reflected Ceiling Plans) Shear Wall Shaft Wall X Representing Shaft Opening - Opening In Wall Related To Shafts, Etc Walls Around Stairs Walls Around Tracks Walls Around Tracks Below Hidden Walls Around Tracks Wall Vents

ABVE BARR BLOW BOTH CASE CNPY FGPN FNSH GYPB KWAL KWAL MISC MOVE OTLN OTLN OTLN PRHT SHER SHFT SHFT STRS TRAK TRAK TRAK VENT

NFIL OTLN

ABVE BLOW

OPNG

BLOW HIDN

8 212 1 8 250 212

Last Updated: March 2010

Page 61

Engineering Department Manual


E/A Design Division CAD Standard
Discipline Linetype

Phase

Minor

Major

Color

Plots

Desc

Description

A A A A A A A A A A A A A A A A A A A A A A A A A A A A

XREF XREF XREF XREF XREF XREF XREF XREF XREF XREF XREF XREF XREF XREF XREF XREF XREF XREF XREF XREF XREF XREF XREF XREF XREF XREF XREF XREF

_OLE BLDG BLDG BLDG BLDG BLDG BORD CLNG COLS COLS CURB CURB CURB ELEV ESCL ESCL FLOR GRID INDX KPLN LAND RAST SECT SGRD SGRD SITE TRAF TRAK

ABVE BLOW DETL NTRY

_STL CLIN ABVE BLOW

BLOW COOR

STRU UTIL STRP

255 8 8 5 5 5 255 255 255 255 8 8 8 255 5 8 255 255 255 255 255 255 255 255 255 255 255 255

Continuous Continuous HIDDEN HIDDEN HIDDEN Continuous Continuous Continuous Continuous Continuous Continuous HIDDEN HIDDEN Continuous Continuous DOT4 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous

Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

Layer To Attach Ole Linked Files Onto (I.E. Excel, Access Or Word) Xref Building Onto Xref Building Above Onto Xref Building Below Onto Xref Building Details Onto Xref Building Entry Level Onto Xref Borders And Associated Attributes Onto Xref Rcp's Onto Xref Column Stl/Enclosure Onto Xref Column Grids Centerlines Onto Street Curbs Xref Street Curbs Above Onto Street Curbs Below Xref Elevations Onto Escalator Escalator Below Xref Floor Plan Onto Xref Coordinate Grid Onto Layer To Xref Drawing Index Onto Xref Key Plan Onto Xref Landscape Onto Raster Images Xref Sections Onto Xref Structural Sub Grade Onto Xref Sub Grade Utilities Onto Xref Site Plan Onto Xref Traffic Stripping Onto Xref Tracks Onto

6.17.2.2
Discipline Minor Major

LANDSCAPE NEW WORK


Linetype Phase Color Plots Desc

Description

Annotation L ANNO L ANNO L ANNO L ANNO L ANNO L ANNO L ANNO L ANNO L ANNO L ANNO L ANNO

_BUS _CLL _CUT BREK CARS CLIN DIMS DIMS DETL GDLN LGND

5 4 8 5 8 8 1 1 3 113 1

Continuous Continuous Continuous Continuous Continuous CENTER5 DOT8 Continuous Continuous Continuous Continuous

Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

Buses Contract Limit Line Cut Line Break Line Cars Centerline Dimension Guide Line Dimensions Detail Symbol Guideline Legend Disclaimer

Last Updated: March 2010

Page 62

Engineering Department Manual


E/A Design Division CAD Standard
L L L L L L L L L L L L L L L L L L L ANNO ANNO ANNO ANNO ANNO ANNO ANNO ANNO ANNO ANNO ANNO ANNO ANNO ANNO ANNO ANNO ANNO ANNO ANNO LGND MLIN NOTE PEOP REDL SCUT SCUT SCUT SYMB SYMB SYMB SYMB TEXT TEXT TEXT TEXT TEXT TEXT TEXT 212 4 212 8 10 5 212 3 3 5 1 3 1 5 5 5 212 1 212 3 212 1 8 8 5 200 255 40 40 41 40 3 1 212 212 252 252 1 252 212 8 212 3 8 Continuous DIVIDE2 Continuous Continuous Continuous Continuous DOT8 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous HIDDEN2 Continuous Continuous Continuous Continuous Continuous Continuous Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No Yes No No No No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Legends And Symbols Associated With Legends Match Line Miscellaneous Notes People Redline Directional Arrow Section Cut Line Connecting Head And Tail Section Cut Symbol Miscellaneous Symbols North Arrow Scale Bar Symbol Block Insertion Layer Contract Limit Line Text Presentation Date Text Leader Line Secondary Text Match Line Text Property Line Text Right Of Way Text Title Text Text Street Name Text Trains, Subways & Monorails Trucks Drawing Title On Presentation Border View Port Creation Layer View Port Shade (For Presentation) Area Calculation Area Calculation Boundary Lines Area Hatch Plant Name And Quantity Chart Border Chart Line Chart Text Chart Title Elevation Or Section Objects In The Distance Trees In The Distance (Background) Elvation Or Section Objects Obscured By Forground Objects Shrub The Distance (Background) Major Contour Lines Minor Contour Lines Major Contour Line Label Text Key Plan Border Key Plan Hatch

L ANNO TEXT L ANNO TEXT L ANNO TEXT L ANNO TRAN L ANNO TRUK L ANNO TTLB L ANNO VPRT L ANNO VPRT Area - All Area Layers Are Non Plot L AREA IDEN L AREA OTLN L AREA PATT L AREA PLNT Chart L CHRT _BDR L CHRT LINE L CHRT TEXT L CHRT TITL Elevation L ELEV BYND L ELEV TREE L ELEV L ELEV Grading L GRAD L GRAD L GRAD Key Plan L KPLN L KPLN HIDN SHRB INDX INTR TEXT _BDR HTCH

Last Updated: March 2010

Page 63

Engineering Department Manual


E/A Design Division CAD Standard
L Plan L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L KPLN PLAN PLAN PLAN PLAN PLAN PLAN PLAN PLAN PLAN PLAN PLAN PLAN PLAN PLAN PLAN PLAN PLAN PLAN PLAN PLAN PLAN PLAN PLAN PLAN PLAN PLAN PLAN PLAN PLAN PLAN PLAN PLAN PLAN PLAN PLAN PLAN PLAN PLAN PLAN PLAN PLAN PLAN PLAN PLAN PLAN PLAN PLAN PLAN PLAN TEXT _HDR _ROW ABTM ARCH BLDG BLDG BLDG BOLL BRDG BULB BULB CNPY COLS CONC CONC CONC CONC CONC CURB CURB CIVL EROS EROS FENC FENC FURN GMLH GMLH JBAR LGHT LGHT LINE LINE LINE LINE LMOD MISC MISC MISC PILE PRNL PRNL PROP RRIP SCRN SCRN SEED SEED SHRB 1 5 1 3 253 1 8 4 212 8 15 5 8 8 17 252 1 1 5 5 212 253 5 212 212 212 1 5 1 252 1 1 4 3 1 8 1 253 31 1 5 1 5 1 8 1 212 212 31 1 Continuous Continuous PHANTOM5 Continuous Continuous DASHED Continuous Continuous Continuous Continuous Continuous Continuous DASHED2 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous FENCE FENCE Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous DASHDOT4 Continuous Continuous Continuous Continuous Continuous Continuous Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Key Plan Text Header Right Of Way Line Bridge Abutment Architectural Miscellaneous Building Above Outline Building Hatch Building Outline Bollard Bridge Bulb Fill Area To Receive Bulb Planting Canopy Column Concrete Accent Band Concrete Fill Expansion Joint Concrete Scoreline Area To Receive Concrete Back Of Curb Face Of Curb Water Quality Filtration Trench Erosion Control Mat Fill Area To Receive Erosion Control Mat Chain Link Fence Picket Fence Site Furniture Gravel Mulch Fill Area To Receive Gravel Mulch Jersey Barrier Landscape Light Street Light Heavy Linework Medium Linework Fine Linework Extra Fine Linework Limit Of Disturbance Miscellaneous Electrical Miscellaneous Hatch Outline Miscellaneous Site Features Piles Perennial Fill Area To Receive Perennials Property Line Rip Rap Fill Stone Screenings Fill Area To Receive Stone Screenings Seed Fill Area To Receive Seed Shrub Fill

Last Updated: March 2010

Page 64

Engineering Department Manual


E/A Design Division CAD Standard
L PLAN SHRB L PLAN SLEV L PLAN SLFN L PLAN SPAD L PLAN SPOT L PLAN SSPL L PLAN SSPL L PLAN SSPL L PLAN SSPL L PLAN SSPL L PLAN SSPL L PLAN SWLK L PLAN TEXT L PLAN TRAF L PLAN TRAF L PLAN TRAF L PLAN TRAF L PLAN TRAF L PLAN TRAF L PLAN TRAF L PLAN TRAK L PLAN TREE L PLAN TREE L PLAN TREE L PLAN TREE L PLAN WALL L PLAN WATR L PLAN WETL L PLAN WETL L PLAN WETL L PLAN WETL Revisions L REVS BUBL L REVS SYMB Plant Schedule L SCHD PLNT L SCHD PLNT L SCHD PLNT L SCHD PLNT L SCHD PLNT Section L SECT CARS L SECT CONC L SECT CONC L SECT DGAB L SECT EROS L SECT ERTH L SECT ERTH L SECT __GC L SECT GRAV L SECT LINE 212 5 1 251 1 253 8 8 1 1 1 253 212 253 251 251 253 253 253 253 8 5 1 212 8 212 5 1 1 1 212 3 3 255 4 212 1 3 5 1 5 251 212 252 40 5 8 1 Continuous Continuous DASHDOT DASHED5 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous DASHEDX2 Continuous DASHED5 HIDDENX2 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Area To Receive Shrubs Irrigation Sleeve Silt Fence Spade Cut Edge Spot Elevation Salt Splash Fill Ewr Type A Salt Splash Ewr Type B Salt Splash Jfk Salt Splash Lga Salt Splash Swf Salt Splash Sidewalk Plan Text Guard Rail (W-Beam Or Box Beam) Parking Stalls Handicap Parking Miscellaenous Traffic Items Traffic Sign Wheel Stops General Pavement Markings Tracks Ornamental Tree Evergreen Tree Canopy Tree Tree Protection Box Retaining Wall Water Edge Goose Stake Flag Mean High Water Mean Low Water Water Fowl Fencing Revisions Bubble Revisions Text Plant Schedule Insertion Layer (Autocad Table) Plant Schedule Border Plant Schedule Lines Plant Schedule Text Plant Schedule Title Vehicles Concrete Fill Area To Receive Concrete Dgabc Erosion Control Mat Earth Fill Area To Receive Earth Ground Cover Gravel Mulch Fine Linework

Last Updated: March 2010

Page 65

Engineering Department Manual


E/A Design Division CAD Standard
L L L L L L L L L L L L L L L L L Site L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L Xref L SECT SECT SECT SECT SECT SECT SECT SECT SECT SECT SECT SECT SECT SECT SECT SECT SECT SITE SITE SITE SITE SITE SITE SITE SITE SITE SITE SITE SITE SITE SITE SITE SITE SITE SITE SITE SITE SITE SITE SITE SITE SITE SITE SITE SITE SITE SITE SITE XREF LINE LINE LINE MISC MISC PEOP PRNL PROF PROF PROF SAND SHRB TEXT TREE TREE TREE TREE BLDG BLDG BLDG BLDG CONC CONC CONC _HDR LAWN LAWN LDSP LDSP MISC PRNL PRNL PRNL SHRB SHRB SHRB SSPL SSPL TREE TREE TREE TREE WATR WATR WATR WETL WETL WETL _BDR 3 8 4 253 31 5 1 5 3 212 1 1 212 252 5 8 1 212 252 253 4 17 252 5 252 63 31 61 8 251 1 253 212 1 253 212 251 1 253 1 1 5 121 131 133 143 72 41 255 Continuous Continuous Continuous Continuous Continuous Continuous Continuous DOT2 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous DASHED Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Medium Linework Extra Fine Linework Heavy Linework Miscellaneous Hatch Miscellaneous Outline People Perennial Profile Guidelines Proposed Profile Profile Text Sand Setting Bed Shrub Section Text Tree In Background Evergreen Tree Ornamental Tree Canopy Tree Building Above Outline Building Fill Building Shadow Building Outline Concrete Accent Band Concrete Fill Area To Receive Concrete Header (Flush Curb) Lawn Fill Area To Receive Lawn Landscape Fill Landscaped Area Miscellaneous Hatch Perennial Fill Perennial Shadow Area To Receive Perennials Shrub Fill Shrub Shadow Area To Receive Shrubs Salt Splash Fill Area To Receive Salt Splash Tree Shadow Canopy Tree Evergreen Tree Ornamental Tree Heavy Water Fill Light Water Fill Medium Water Fill Channel Iva Wetland Plants Spartina Xref Border And Attributes

Last Updated: March 2010

Page 66

Engineering Department Manual


E/A Design Division CAD Standard
L L L L L L L XREF XREF XREF XREF XREF XREF XREF CLIP CURB _DTL SCRN NOTE SECT SITE 255 255 255 255 255 255 255 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Yes Yes Yes Yes Yes Yes Yes Xclip Xref Curbs Xref Details Xref Of Screened Background Xref Specs And Notes Xref Sections Xref Site Plan

6.17.2.3
Discipline Minor Major

LANDSCAPE EXISTING WORK


Linetype Phase Color Plots Desc

Description

Default Existing Layer Properties (Unless Otherwise Noted Below) L ____ ____ ANNOTATION L ANNO CLIN L ANNO DIMS ELEVATION L ELEV PLAN L PLAN L PLAN L PLAN L PLAN L PLAN L PLAN L PLAN L PLAN L PLAN SECTION L SECT SITE L SITE L SITE L SITE HIDN _ROW BLDG CNPY FENC FENC PROP SLFN SPAD WATR PROF BLDG LDSP LDSP ____ ____ ____ EXST EXST EXST 253 253 253 Continuous CENTER5 DOT8 Yes Yes Yes Existing Centerline Existing Dimension Guide Line Existing Elevation Or Section Objects Obscured By Foreground Objects Existing Right Of Way Line Existing Building Above Outline Existing Canopy Existing Chain Link Fence Existing Picket Fence Existing Property Line Existing Silt Fence Existing Spade Cut Edge Existing Water Edge Existing Profile Guidelines Existing Building Above Outline Existing Landscape Fill Existing Landscaped Area

____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____

EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST

253 253 253 253 253 253 253 253 253 253 253 253 43 31

HIDDEN2 PHANTOM5 DASHED DASHED2 FENCE FENCE DASHDOT4 DASHDOT DASHED5 DASHEDX2 DOT2 DASHED Continuous Continuous

Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

6.17.2.4
Discipline Minor Major

LANDSCAPE FUTURE WORK


Linetype Phase Color Plots Desc

Description

Default Future Layer Properties (Unless Otherwise Noted Below) L ____ ____ ANNOTATION L ANNO CLIN L ANNO DIMS ELEVATION ____ ____ ____ FUTR FUTR FUTR 212 212 212 Continuous CENTER5 DOT8 Yes Yes Yes Future Centerline Future Dimension Guide Line

Last Updated: March 2010

Page 67

Engineering Department Manual


E/A Design Division CAD Standard
Future Elevation Or Section Objects Obscured By Foreground Objects Future Right Of Way Line Future Building Above Outline Future Canopy Future Chain Link Fence Future Picket Fence Future Property Line Future Silt Fence Future Spade Cut Edge Future Water Edge Future Profile Guidelines Future Building Above Outline

L ELEV PLAN L PLAN L PLAN L PLAN L PLAN L PLAN L PLAN L PLAN L PLAN L PLAN SECTION L SECT SITE L SITE

HIDN _ROW BLDG CNPY FENC FENC PROP SLFN SPAD WATR PROF BLDG

____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____

FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR

212 212 212 212 212 212 212 212 212 212 212 212

HIDDEN2 PHANTOM5 DASHED DASHED2 FENCE FENCE DASHDOT4 DASHDOT DASHED5 DASHEDX2 DOT2 DASHED

Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

6.17.2.5
Discipline Major

LANDSCAPE RELOCATED WORK


Linetype Phase Minor Color Plots Desc

Description

Default Relocate Layer Properties (Unless Otherwise Noted Below) L ____ ____ CLIN DIMS ____ ____ ____ RELO RELO RELO 212 212 212 Continuous CENTER5 DOT8 Yes Yes Yes Relocated Centerline Relocated Dimension Guide Line Relocated Elevation Or Section Objects Obscured By Foreground Objects Relocated Right Of Way Line Relocated Building Above Outline Relocated Canopy Relocated Chain Link Fence Relocated Picket Fence Relocated Property Line Relocated Silt Fence Relocated Spade Cut Edge Relocated Water Edge Relocated Profile Guidelines Relocated Building Above Outline ANNOTATION L ANNO L ANNO ELEVATION L ELEV PLAN L PLAN L PLAN L PLAN L PLAN L PLAN L PLAN L PLAN L PLAN L PLAN SECTION L SECT SITE L SITE

HIDN _ROW BLDG CNPY FENC FENC PROP SLFN SPAD WATR PROF BLDG

____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____

RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO

212 212 212 212 212 212 212 212 212 212 212 212

HIDDEN2 PHANTOM5 DASHED DASHED2 FENCE FENCE DASHDOT4 DASHDOT DASHED5 DASHEDX2 DOT2 DASHED

Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

6.17.2.6
Discipline Minor Major

LANDSCAPE REMOVAL WORK


Linetype Phase Color Plots Desc

Description

Last Updated: March 2010

Page 68

Engineering Department Manual


E/A Design Division CAD Standard
Default Removal Layer Properties (Unless Otherwise Noted Below) L ____ ____ ANNOTATION L ANNO CLIN L ANNO DIMS ELEVATION L ELEV PLAN L PLAN L PLAN L PLAN L PLAN L PLAN L PLAN L PLAN L PLAN SECTION L SECT SITE L SITE HIDN _ROW BLDG CNPY FENC FENC PROP SLFN SPAD PROF BLDG ____ ____ ____ RMVL RMVL RMVL 212 212 212 Continuous CENTER5 DOT8 Yes Yes Yes Removal Centerline Removal Dimension Guide Line Removal Elevation Or Section Objects Obscured By Foreground Objects Removal Right Of Way Line Removal Building Above Outline Removal Canopy Removal Chain Link Fence Removal Picket Fence Removal Property Line Removal Silt Fence Removal Spade Cut Edge Removal Profile Guidelines Removal Building Above Outline

____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____

RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL

212 212 212 212 212 212 212 212 212 212 212

HIDDEN2 PHANTOM5 DASHED DASHED2 FENCE FENCE DASHDOT4 DASHDOT DASHED5 DOT2 DASHED

Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

6.17.2.7
Discipline Minor Major

LANDSCAPE TEMPORARY WORK


Linetype Phase Color Plots Desc

Description

Default Temporary Layer Properties (Unless Otherwise Noted Below) L ____ ____ ANNOTATION L ANNO CLIN L ANNO DIMS ELEVATION L ELEV PLAN L PLAN L PLAN L PLAN L PLAN L PLAN L PLAN L PLAN L PLAN L PLAN SECTION L SECT SITE L SITE HIDN _ROW BLDG CNPY FENC FENC PROP SLFN SPAD WATR PROF BLDG ____ ____ ____ TEMP TEMP TEMP 212 212 212 Continuous CENTER5 DOT8 Yes Yes Yes Temporary Centerline Temporary Dimension Guide Line Temporary Elevation Or Section Objects Obscured By Foreground Objects Temporary Right Of Way Line Temporary Building Above Outline Temporary Canopy Temporary Chain Link Fence Temporary Picket Fence Temporary Property Line Temporary Silt Fence Temporary Spade Cut Edge Temporary Water Edge Temporary Profile Guidelines Temporary Building Above Outline

____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____

TEMP TEMP TEMP TEMP TEMP TEMP TEMP TEMP TEMP TEMP TEMP TEMP

212 212 212 212 212 212 212 212 212 212 212 212

HIDDEN2 PHANTOM5 DASHED DASHED2 FENCE FENCE DASHDOT4 DASHDOT DASHED5 DASHEDX2 DOT2 DASHED

Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

Last Updated: March 2010

Page 69

Engineering Department Manual


E/A Design Division CAD Standard

6.17.3 LINETYPES
Description Centerline (1x) Centerline (0.20x) Continuous Example

Name
CENTER

CENTER5

Continuous

DASHDOT

Dashdot (1x)

DASHDOT4

Dashdot (0.25x)

DASHED

Dashed (1x)

DASHED2

Dashed (0.50x)

DASHED4

Dashed (0.25x)

DASHED5

Dashed (0.20x)

DASHEDX2

Dashed (2x)

DIVIDE2

Divide (0.50x)

DIVIDE4

Divide (0.25x)

DOT2

Dot (0.50x)

DOT4

Dot (0.25x)

DOT5

Dot (0.20x)

DOT8 FENCE

Dot (0.125x) Fence (1x)

Last Updated: March 2010

Page 70

Engineering Department Manual


E/A Design Division CAD Standard Name
HIDDEN Description Hidden (1x) Example

HIDDEN2

Hidden (0.50x)

HIDDEN4

Hidden (0.25x)

HIDDEN5 HIDDEN3_TO_3

Hidden (0.20x)

Hidden (1.5x)

HIDDENX2

Hidden (2x)

PHANTOM4

Phantom (0.25x)

PHANTOM5

Phantom (0.20x)

Last Updated: March 2010

Page 71

Engineering Department Manual


E/A Design Division CAD Standard

6.17.4 SYMBOLS 6.17.4.1 DRAFTING CONVENTIONS


Symbol Block Name 22x34PSG.dwg ABBREV_1.dwg ARROW.dwg BREAK.dwg CLINE.dwg COLNO.dwg COLNOE.dwg COLNOP.dwg DETNO2.dwg DETNO3.dwg DETNO.dwg DETNODBL.dwg DETNO-SM.dwg DIMGUIDE.dwg DOORNO.dwg EXIT-1WAYDIR.dwg EXIT-2WAYDIR.dwg EXIT.dwg Layer Name Varies Varies Varies Varies Varies Varies Varies Varies Varies Varies Varies Varies Varies Varies Varies Varies Varies Varies Description 22 x 34 Layout Guide List of Abbreviations and Symbols Arrow Head Break Line Center Line Column Number for Contract Drawings Column Number for Existing Columns Column Number for Presentation Drawings Contract Drawing Label No Scale Bar Presentation Drawing Label Contract Drawing Label Double Contract Drawing Label Contract Drawing Label Condensed Guideline Used with Dimensions for Contract Drawings Door Number Directional Exit Sign Multi-Directional Exit Sign Exit Sign

Last Updated: March 2010

Page 72

Engineering Department Manual


E/A Design Division CAD Standard

EXIT-DBL-1WAYDIR.dwg EXIT-DBL-2WAYDIR.dwg EXIT-DBL.dwg INSUL.dwg INT-ELEV.dwg LEVELINE.dwg LOCALSEC.dwg OUTLET.dwg PARTTYPE.dwg RETURN.dwg REV-NO.dwg RM-NO.dwg SPEAKER.dwg SPNKHD.dwg SUPPLY.dwg TARG1.dwg TARGELEV.dwg TARGSEC.dwg TARGSECHEAD.dwg TARGSECTAIL.dwg

Varies Varies Varies Varies Varies Varies Varies Varies Varies Varies Varies Varies Varies Varies Varies Varies Varies Varies Varies Varies

Double-Sided Directional Exit Sign Double-Sided Multi-Directional Exit Sign Double-Sided Exit Sign Insulation Interior Elevation Level Line Presentation Section Mark Electric Outlet Partition/Wall Type Mechanical Return Duct Symbol Revision Tag Room Number Speaker Sprinkler Head Mechanical Supply Duct Detail/Section/Elevation Label Elevation Symbol Complete Section Symbol Section Head Symbol Section Tail Symbol

Last Updated: March 2010

Page 73

Engineering Department Manual


E/A Design Division CAD Standard

W-ARROW.dwg WIN-NO.dwg

Varies Varies

Presentation Arrow Window Type

6.17.4.2

2D PEOPLE
Symbol Block Name Layer Name Description

MAN01.dwg

Varies

Man Standing

MAN02.dwg

Varies

Man Walking

MAN03.dwg

Varies

Man Sitting

MAN04.dwg

Varies

Man Standing Back View

MAN05.dwg

Varies

Man Standing Side View

MAN06.dwg

Varies

Man Walking 2

MAN07.dwg

Varies

Man Standing 2

MAN08.dwg

Varies

Man Outline

PEOPLE01.dwg

Varies

Man and Woman Walking

Last Updated: March 2010

Page 74

Engineering Department Manual


E/A Design Division CAD Standard

PEOPLE02.dwg

Varies

Man and Woman Walking 2

PEOPLE03.dwg

Varies

Two Women Walking

PEOPLE04.dwg

Varies

Man and Woman Standing

PEOPLE05.dwg

Varies

Father and Child

PEOPLE06.dwg

Varies

Mother and Daughter

PEOPLE07 dwg

Varies

Two Men Standing

PEOPLE08.dwg

Varies

Two Men Side View

PEOPLE09.dwg

Varies

Outline Three People

PEOPLE10.dwg

Varies

People Waiting to Get on Bus

WOMAN01.dwg

Varies

Woman Telling Time

WOMAN02.dwg

Varies

Woman Walking

Last Updated: March 2010

Page 75

Engineering Department Manual


E/A Design Division CAD Standard

WOMAN03.dwg

Varies

Woman Walking 2

WOMAN04.dwg

Varies

Woman Standing

WOMAN05.dwg

Varies

Woman Lying Down

WOMAN06.dwg

Varies

Woman Outline 1

WOMAN07.dwg

Varies

Woman Outline 2

6.17.4.3

2D VEHICLES
Symbol Block Name 02EBUS01.dwg Layer Name Varies Description School Bus

02EBUS02.dwg

Varies

City Bus

02ECAR01.dwg

Varies

Hatchback Car

02ECAR02.dwg

Varies

Sedan Car

02ECAR04.dwg

Varies

Classic Car

02ECAR06.dwg

Varies

Flatbed Pickup Truck

Last Updated: March 2010

Page 76

Engineering Department Manual


E/A Design Division CAD Standard

02ECAR08.dwg

Varies

Porsche

02ECAR09.dwg

Varies

Porsche with Spoiler

02ECAR10.dwg

Varies

Lotus Espirit

02ECAR11.dwg

Varies

Sports Car

02ECAR12.dwg

Varies

Car Sedan

02ECAR14.dwg

Varies

Old Car

02ECAR19.dwg

Varies

Lamborghini

02ECAR21.dwg

Varies

Eurovan

bus1.dwg

Varies

Minibus

bus03-cross-countrybus.dwg

Varies

Cross-Country Bus

BUS-2.DWG

Varies

City Bus 3

BUS.DWG

Varies

City Bus 2

BUS-F.dwg

Varies

Bus Front View

BUS-pl.dwg

Varies

Bus and Taxi Top View

Last Updated: March 2010

Page 77

Engineering Department Manual


E/A Design Division CAD Standard

car03-mercedes-benz.dwg

Varies

Mercedes-Benz Side View

car05-station-wagon.dwg

Varies

Station Wagon

car07-vette.dwg

Varies

Chevrolet Corvette

car13-police-car.dwg

Varies

Police Cruiser

car20-bmw3251.dwg

Varies

BMW 325i

car22-sedan.dwg

Varies

Midsize Sedan

CARB.DWG

Varies

Car Front View

CAREL.DWG

Varies

Sports Car Side View

CORSAIR2.DWG

Varies

Corsair Jet

mercedes-front.dwg

Varies

Mercedes-Benz Front View

minibus.dwg

Varies

Minibus Multiple Views

MOTORCY.dwg

Varies

Motorcycle

PTRUCK-2.DWG

Varies

Pickup Truck with Plexiglas Cover

TAXI-F.dwg

Varies

Taxi

Last Updated: March 2010

Page 78

Engineering Department Manual


E/A Design Division CAD Standard

TRUCKPL.dwg

Varies

Truck Top View

volkswagen.dwg

Varies

Volkswagen Beetle

6.17.4.4

3D SITE AMENITIES
Symbol Block Name 3DBENC1.dwg Layer Name Varies Description 3D Bench 1

3DBENC2.dwg

Varies

3D Bench 2

3DBENC3.dwg

Varies

3D Bench 3

3DBENC4.dwg

Varies

3D Bench 4

3DDECI1.dwg

Varies

3D Deciduous Tree 1

3DDECI2.dwg

Varies

3D Deciduous Tree 2

3DDECI3.dwg

Varies

3D Deciduous Tree 3

3DDECI4.dwg

Varies

3D Deciduous Tree 4

3DEVERG2.dwg

Varies

3D Evergreen Tree 1

3DEVERG.dwg

Varies

3D Evergreen Tree 2

lamppost.dwg

Varies

Lamppost

Last Updated: March 2010

Page 79

Engineering Department Manual


E/A Design Division CAD Standard

SHRUB-1.dwg

Varies

Shrub 1

SHRUB-2.dwg

Varies

Shrub 2

SHRUB-3.dwg

Varies

Shrub 3

STLIGH-1.dwg

Varies

Street Light

TREE-1.dwg

Varies

Tree 1

TREE-1A.dwg

Varies

Tree 1a

TREE-3.dwg

Varies

Tree 3

TREE-4.dwg

Varies

Tree 4

TREE-5.dwg

Varies

Tree 5

TREE-6.dwg

Varies

Tree 6

TREESC-1.dwg

Varies

Tree 7

6.17.4.5

3D VEHICLES
Symbol Block Name 3DTRCK2.dwg Layer Name Varies Description 3D Truck

3DTRCK3.dwg

Varies

3D Truck 2

Last Updated: March 2010

Page 80

Engineering Department Manual


E/A Design Division CAD Standard

3DTRCK4.dwg

Varies

3D Truck 3

3DTRCK5.dwg

Varies

3D Truck 4

3DTRCK.dwg

Varies

3D Truck 5

bus.dwg

Varies

Bus

ferry-boat.dwg

Varies

Ferry Boat

6.17.4.6

FIXTURES
Symbol Block Name LAV4-frt.dwg Layer Name A-EQPM-FIXT Description Four-Sink Lavatory Front View

LAV4-top.dwg

A-EQPM-FIXT

Four-Sink Lavatory Top View

LAV-frt.dwg

A-EQPM-FIXT

Lavatory Front View

LAV-sid.dwg

A-EQPM-FIXT

Lavatory Side View

LAV-TOP.dwg

A-EQPM-FIXT

Lavatory Top View

MIRR1.dwg

Varies

Horizontal Mirror

MIRR2.dwg

Varies

Vertical Mirror

NAP-FRT.dwg

Varies

Front Elevation of Napkin Dispenser (Female)

Last Updated: March 2010

Page 81

Engineering Department Manual


E/A Design Division CAD Standard

NURS-FRT.dwg

Varies

Nursing Station Front View

NURS-TOP.dwg

Varies

Nursing Station Top View

TOIL1-frt.dwg

A-EQPM-FIXT

Toilet Front View

TOIL1-sid.dwg

A-EQPM-FIXT

Toilet Side View

TOIL1-top.dwg

A-EQPM-FIXT

Toilet Top View

TOIL2-frt.dwg

A-EQPM-FIXT

Toilet 2 Front View

TOIL2-sid.dwg

A-EQPM-FIXT

Toilet 2 Side View

TOIL2-top.dwg

A-EQPM-FIXT

Toilet 2 Top View

TOWEL.dwg

Varies

Towel Dispenser

URI-frt.dwg

A-EQPM-FIXT

Urinal Front View

URI-sid.dwg

A-EQPM-FIXT

Urinal Side View

URI-top.dwg

A-EQPM-FIXT

Urinal Top View

6.17.4.7

MATERIAL CONVENTIONS
Symbol Block Name CARPET.dwg Layer Name A-FLOR-PATT Description Carpe

Last Updated: March 2010

Page 82

Engineering Department Manual


E/A Design Division CAD Standard

CEILING.dwg

Varies

Ceiling

CMU04.dwg

Varies

4-Inch Glazed Brick Masonry

CMU06.dwg

Varies

6-Inch Glazed Brick Masonry

CMU08.dwg

Varies

8-Inch Glazed Brick Masonry

CMU10.dwg

Varies

10-Inch Glazed Brick Masonry

COARSE.dwg

Varies

Coarse, Pourus Fill

CONC01.dwg

Varies

Concrete

CONC02.dwg

Varies

4-Inch Concrete

DECKTOP2.dwg

Varies

Metal Deck and Concrete Topping Longitudinal Cross-Section

DECKTOP.dwg

Varies

Metal Deck and Concrete Topping Cross-Section

EARTH.dwg

Varies

Earth

FINE.dwg

Varies

Fine, Porous Fill

GLAZE-B.dwg

Varies

Glazed Brick Masonry

GYPBD.dwg

Varies

Gypsum Board

Last Updated: March 2010

Page 83

Engineering Department Manual


E/A Design Division CAD Standard

H-REIN.dwg

Varies

Horizontal Concrete Reinforcement

INSUL.dwg

Varies

BATT Insulation

MTLDECK.dwg

Varies

Metal Deck Cross Section

PARTICLE.dwg

Varies

Particleboard

PLASTER.dwg

Varies

Lath and Plaster

PLYWOOD1.dwg

Varies

Millwork Plywood

PLYWOOD2.dwg

Varies

Plywood

PRECONC.dwg

Varies

Pre-Cast Concrete

RESIL.dwg

Varies

Resilient Flooring

RKTMP.dwg

Varies

???

STONE.dwg

Varies

Cut Stone

TERRAZZO.dwg

Varies

Terrazzo

TILE.dwg

Varies

Ceramic Tile

WDBLOCK.dwg

Varies

Wood Blocking

Last Updated: March 2010

Page 84

Engineering Department Manual


E/A Design Division CAD Standard

WDSHIM.dwg

Varies

Wood Shim

WOOD.dwg

Varies

Wood

Last Updated: March 2010

Page 85

Engineering Department Manual


E/A Design Division CAD Standard

6.18

APPENDIX B CIVIL DISCIPLINE

6.18.1 CONTENT PREFERENCES This Section Is Under Construction

Last Updated: March 2010

Page 86

Engineering Department Manual


E/A Design Division CAD Standard 6.18.2 LAYER STRATAGEM 6.18.2.1
Discipline Minor Major

NEW WORK
Linetype Phase Color Plots Desc

Description

Alignment C ALGN C ALGN C ALGN C ALGN C ALGN C ALGN C ALGN C ALGN C ALGN C ALGN C ALGN C ALGN C ALGN C ALGN C ALGN C ALGN C ALGN C ALGN C ALGN C ALGN Annotation C ANNO C ANNO C ANNO C ANNO C ANNO C ANNO C ANNO C ANNO C ANNO C ANNO C ANNO C ANNO C ANNO C ANNO Details C DETL C DETL C DETL Grading C GRAD C GRAD

BRNG COGO CRVE DIMS GAGE _HOR _HOR NOTE PCPT PROF PROP ROWL STAT SWCH TPRD TRAK TRAK TRAK TRAK VERT CHNG COGO CONS DIMS LGND MTCH NARW NOTE REVS SCLE TABL TEXT TITL VPRT

131 100 131 100 131 131 131 121 100 251 100 131 100 100 131 131 131 131 131 131 92 252 30 1 121 172 121 121 220 121 131 100 172 200 131 100 121 100 220

Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Phantom2 Phantom Continuous Continuous Continuous RR RR RR RR Continuous Divide Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous

Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

Bearings Coordinate Geometry Information Curve Numbers Alignment Dimensions Gauge Line, Track Road/Taxiway/Runway Edge Alignments Temporary Centerline, Horizontal Alignment Alignment Annotations And Notes Pc/Pt/Pcc/Prc/Poc Bubbles And Text Profile Grid Property Lines And Text Right Of Way Lines And Text Alignment Stations And Text Point Of Switch Temporary Road Alignments Track Alignment Gauge Line, Track Point Of Switch Top Of Rail Top At Rail Identification Of Updated Work Coordinate Geometry Grid Construction Lines Dimensions Legend Items Match Line North Arrow Notes Revision Bubble And Triangle Scale Bar Curve Data Table, Drainage Table, Etc Misc. Text & Callouts With Assoc. Leaderlines Titles View Port Detail Features Detail Dimensions Detail Notes And Annotations Grading Dimensions Index Contours

DIMS NOTE DIMS INDX

Last Updated: March 2010

Page 87

Engineering Department Manual


E/A Design Division CAD Standard
C GRAD INTR C GRAD LIMT C GRAD NOTE C GRAD COGO C GRAD SPOT Pavement Markings C MARK AIRS C MARK DIMS C MARK NOTE C MARK PARK C MARK ROAD C MARK COGO C MARK TEXT Paving C PAVE ASPH C PAVE COGO C PAVE BRDR C PAVE CONC C PAVE CURB C PAVE CURB C PAVE DIMS C PAVE GRAV C PAVE JBAR C PAVE JNTS C PAVE LIMT C PAVE NOTE C PAVE SECT Profiles C PROF C PROF BASE C PROF XING C PROF NOTE C PROF FGCL C PROF TEXT Sections C SECT C SECT DIMS C SECT NOTE C SECT SMPL C SECT VIEW C SECT VIEW Site Plans C SITE ABUT C SITE BLDG C SITE BLDG C SITE FNCE C SITE FNDN C SITE GUID C SITE LAND C SITE NOTE C SITE SIGN 92 13 121 121 12 220 100 121 220 220 100 100 12 121 14 12 1 131 100 12 220 220 13 121 172 1 1 131 100 131 100 131 100 121 220 100 100 131 131 100 131 131 131 131 100 220 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Dashed Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Intermediate Contours Limit Of Grading Grading Notes And Annotation Grading Coordinate Geometry Spot Elevations Pavement Markings Airside Pavement Marking Dimensions Pavement Marking Notes And Annotation Pavement Markings Parking Pavement Markings Roads Pavement Marking Coordinate Geometry Misc. Text & Callouts With Assoc. Leader Lines Road, Parking Lot And Airside Paving Coordinate Geometry Data Pavement Hatch Borders Road, Parking Lot And Airside Back Of Curb Face Of Curb Pavement Dimensions Gravel Jersey Barriers Expansion Joints Paving Limits Paving Notes Section Marks Profile Features Profile Base Profile Utility Crossings Profile Notes And Annotations Profile Finished Ground Misc. Text & Callouts With Assoc. Leader Lines Section Features Section Dimensions Section Notes And Annotations Section Sample Lines Section Views Section View Tables Bridge Abutments Buildings, Sheds, Major And Minor Site Features Minor And Major Site Feature Text Fences And Bollards Foundations Guide Rails Landscape Features Site Notes And Annotations Signs

Last Updated: March 2010

Page 88

Engineering Department Manual


E/A Design Division CAD Standard
C SITE SIGN C SITE TICK C SITE COGO C SITE WALL Construction Staging C STAG BRDR C STAG DIMS C STAG NOTE C STAG STAGE C STAG STAG Utilities C UTIL __CB C UTIL __CB C UTIL __MH C UTIL __MH C UTIL FIRE C UTIL FIRE C UTIL FUEL C UTIL FUEL C UTIL GASL C UTIL GASL C UTIL HYDR C UTIL HYDR C UTIL NOTE C UTIL SSMH C UTIL SSMH C UTIL SSWR C UTIL SSWR C UTIL STEM C UTIL STEM C UTIL STEM C UTIL STEM C UTIL STRM C UTIL STRM C UTIL STRM C UTIL STRM C UTIL STRM C UTIL WATR C UTIL WATR C UTIL WATR C UTIL WATR C UTIL WATR C UTIL DIMS C UTIL COGO C UTIL WATR Xref XREF C C XREF RAST 100 121 121 131 12 100 100 12 100 121 100 121 100 121 100 121 100 121 100 121 100 121 121 100 121 100 121 100 121 121 121 121 121 100 121 121 121 121 100 121 121 121 121 121 121 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous HPW Continuous FOS Continuous G Continuous Continuous Continuous Continuous Continuous Continuous SAN Continuous HPS Continuous LPS MPS ST Continuous Continuous Continuous Continuous CW HWS HPW C LPS Continuous Continuous MPS Continuous Continuous Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Sign Text Tick Marks Sitework Coordinate Geometry Walls Hatch Borders Construction Stage Dimensions Construction Stage Notes And Annotations Construction Stage Features Misc. Text & Callouts With Assoc. Leader Lines Catch Basins Catch Basin Text Manholes Other Than Sanitary Or Storm Manholes Text Fire ( High Pressure Water Line) Fire ( High Pressure Water Line) Text Fuel Line Fuel Text Gas Line Gas Text Hydrants Hydrants Text Notes And Annotation Sanitary Sewer Manholes Sanitary Sewer Manholes Text Sanitary Sewer Sanitary Sewer Text High Pressure Steam Line Steam Text Low Pressure Steam Line Medium Pressure Steam Line Storm Drainage Line Storm Drainage Catch Basins Storm Drainage Manholes Storm Drainage Text Sub-Drain Cold Water Line Hot Water Line High Pressure Water Line Water Text Low Pressure Water Line Utility Dimensions Utility Coordinate Geometry Medium Pressure Water Line External Reference Drawings Raster Images

Last Updated: March 2010

Page 89

Engineering Department Manual


E/A Design Division CAD Standard 6.18.2.2
Discipline Minor Major

EXISTING WORK
Linetype Phase Color Plots Desc

Description

Default Existing Layer Properties (Unless Otherwise Noted Below) C ____ Alignment C ALGN C ALGN C ALGN C ALGN C ALGN C ALGN Utilities C UTIL C UTIL C UTIL C UTIL C UTIL C UTIL C UTIL C UTIL C UTIL C UTIL C UTIL C UTIL C UTIL C UTIL ____ PROP ROWL TRAK TRAK TRAK TRAK FIRE FUEL GASL SSWR STEM STEM STEM STRM WATR WATR WATR WATR WATR WATR ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST 253 253 253 253 253 253 253 253 253 253 253 253 253 253 253 253 253 253 253 253 253 Continuous Phantom2 Phantom RR RR RR RR HPW FOS G SAN HPS LPS MPS ST CW HWS HPW C LPS MPS Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Existing Property Lines And Text Existing Right Of Way Lines And Text Existing Track Alignment Existing Gauge Line, Track Existing Point Of Switch Existing Top Of Rail Existing Fire ( High Pressure Water Line) Existing Fuel Line Existing Gas Line Existing Sanitary Sewer Existing High Pressure Steam Line Existing Low Pressure Steam Line Existing Medium Pressure Steam Line Existing Storm Drainage Line Existing Cold Water Line Existing Hot Water Line Existing High Pressure Water Line Existing Water Text Existing Low Pressure Water Line Existing Medium Pressure Water Line

6.18.2.3
Discipline Minor Major

FUTURE WORK
Linetype Phase Color Plots Desc

Description

Default Future Layer Properties (Unless Otherwise Noted Below) C ____ ____ ____ FUTR 253 Continuous Yes Alignment C ALGN PROP ____ 253 Phantom2 Yes FUTR C ALGN ROWL ____ 253 Phantom Yes FUTR C ALGN TRAK ____ 253 RR Yes FUTR C ALGN TRAK ____ 253 RR Yes FUTR C ALGN TRAK ____ 253 RR Yes FUTR C ALGN TRAK ____ 253 RR Yes FUTR Utilities C UTIL FIRE ____ 253 HPW Yes FUTR C UTIL FUEL ____ 253 FOS Yes FUTR C UTIL GASL ____ 253 G Yes FUTR C UTIL SSWR ____ 253 SAN Yes FUTR

Future Property Lines And Text Future Right Of Way Lines And Text Future Track Alignment Future Gauge Line, Track Future Point Of Switch Future Top Of Rail Future Fire ( High Pressure Water Line) Future Fuel Line Future Gas Line Future Sanitary Sewer

Last Updated: March 2010

Page 90

Engineering Department Manual


E/A Design Division CAD Standard
C C C C C C C C C C UTIL UTIL UTIL UTIL UTIL UTIL UTIL UTIL UTIL UTIL STEM STEM STEM STRM WATR WATR WATR WATR WATR WATR ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR 253 253 253 253 253 253 253 253 253 253 HPS LPS MPS ST CW HWS HPW C LPS MPS Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Future High Pressure Steam Line Future Low Pressure Steam Line Future Medium Pressure Steam Line Future Storm Drainage Line Future Cold Water Line Future Hot Water Line Future High Pressure Water Line Future Water Text Future Low Pressure Water Line Future Medium Pressure Water Line

6.18.2.4
Discipline Minor Major

RELOCATE WORK
Linetype Phase Color Plots Desc

Description

Default Relocate Layer Properties (Unless Otherwise Noted Below) C ____ Alignment C ALGN C ALGN C ALGN C ALGN C ALGN C ALGN C ALGN C ALGN C ALGN C ALGN C ALGN C ALGN C ALGN C ALGN C ALGN C ALGN C ALGN C ALGN C ALGN C ALGN Annotation C ANNO C ANNO Details C DETL C DETL C DETL Grading C GRAD C GRAD C GRAD ____ BRNG COGO CRVE DIMS GAGE _HOR _HOR NOTE PCPT PROF PROP ROWL STAT SWCH TPRD TRAK TRAK TRAK TRAK VERT TEXT TITL ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO 4 131 100 131 100 131 131 121 121 100 251 100 131 100 100 131 131 131 131 131 131 100 172 131 100 121 100 220 92 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Phantom2 Phantom Continuous Continuous Continuous RR RR RR RR Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Relocated Bearings Relocated Coordinate Geometry Information Relocated Curve Numbers Relocated Alignment Dimensions Relocated Gauge Line, Track Relocated Road/Taxiway/Runway Edge Alignments Relocated Temporary Centerline, Horizontal Alignment Relocated Alignment Annotations And Notes Relocated Pc/Pt/Pcc/Prc/Poc Bubbles And Text Relocated Profile Grid Relocated Property Lines And Text Relocated Right Of Way Lines And Text Relocated Alignment Stations And Text Relocated Point Of Switch Relocated Temporary Road Alignments Relocated Track Alignment Relocated Gauge Line, Track Relocated Point Of Switch Relocated Top Of Rail Relocated Top At Rail Relocated Misc. Text & Callouts With Assoc. Leaderlines Relocated Titles Relocated Detail Features Relocated Detail Dimensions Relocated Detail Notes And Annotations Relocated Grading Dimensions Relocated Index Contours Relocated Intermediate Contours

DIMS NOTE DIMS INDX INTR

Last Updated: March 2010

Page 91

Engineering Department Manual


E/A Design Division CAD Standard
C C C C GRAD GRAD GRAD GRAD LIMT NOTE COGO SPOT ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ NOTE ABUT BLDG BLDG FNCE FNDN GUID LAND NOTE SIGN SIGN TICK COGO WALL __CB __CB __MH __MH FIRE ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO 13 121 121 12 220 121 220 220 100 100 12 121 14 12 1 131 12 220 220 121 1 131 100 100 131 121 131 131 100 131 131 131 131 100 220 100 121 121 131 121 100 121 100 121 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous HPW Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Relocated Limit Of Grading Relocated Grading Notes And Annotation Relocated Grading Coordinate Geometry Relocated Spot Elevations Relocated Pavement Markings Airside Relocated Pavement Marking Notes And Annotation Relocated Pavement Markings Parking Relocated Pavement Markings Roads Relocated Pavement Marking Coordinate Geometry Relocated Misc. Text & Callouts With Assoc. Leader Lines Relocated Road, Parking Lot And Airside Relocated Paving Coordinate Geometry Data Relocated Pavement Hatch Borders Relocated Road, Parking Lot And Airside Relocated Back Of Curb Relocated Face Of Curb Relocated Gravel Relocated Jersey Barriers Relocated Expansion Joints Relocated Paving Notes Relocated Profile Features Relocated Profile Utility Crossings Relocated Profile Notes And Annotations Relocated Misc. Text & Callouts With Assoc. Leader Lines Relocated Section Features Relocated Section Notes And Annotations Relocated Bridge Abutments Relocated Buildings, Sheds, Major And Minor Site Features Relocated Minor And Major Site Feature Text Relocated Fences And Bollards Relocated Foundations Relocated Guide Rails Relocated Landscape Features Relocated Site Notes And Annotations Relocated Signs Relocated Sign Text Relocated Tick Marks Relocated Sitework Coordinate Geometry Relocated Walls Relocated Catch Basins Relocated Catch Basin Text Relocated Manholes Other Than Sanitary Or Storm Relocated Manholes Text Relocated Fire ( High Pressure Water Line)

Pavement Markings C MARK AIRS C MARK NOTE C MARK PARK C MARK ROAD C MARK COGO C MARK TEXT ASPH COGO BRDR CONC CURB CURB GRAV JBAR JNTS NOTE Paving C PAVE C PAVE C PAVE C PAVE C PAVE C PAVE C PAVE C PAVE C PAVE C PAVE Profiles C PROF C PROF C PROF C PROF Sections C SECT C SECT Site Plans C SITE C SITE C SITE C SITE C SITE C SITE C SITE C SITE C SITE C SITE C SITE C SITE C SITE Utilities C UTIL C UTIL C UTIL C UTIL C UTIL

XING NOTE TEXT

Last Updated: March 2010

Page 92

Engineering Department Manual


E/A Design Division CAD Standard
C C C C C C C C C C C C C C C C C C C C C C C C C C C C C UTIL UTIL UTIL UTIL UTIL UTIL UTIL UTIL UTIL UTIL UTIL UTIL UTIL UTIL UTIL UTIL UTIL UTIL UTIL UTIL UTIL UTIL UTIL UTIL UTIL UTIL UTIL UTIL UTIL FIRE FUEL FUEL GASL GASL HYDR HYDR NOTE SSMH SSMH SSWR SSWR STEM STEM STEM STEM STRM STRM STRM STRM STRM WATR WATR WATR WATR WATR DIMS COGO WATR ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO 100 121 100 121 100 121 100 121 121 100 121 100 121 100 121 121 121 121 121 100 121 121 121 121 100 121 121 121 121 Continuous FOS Continuous G Continuous Continuous Continuous Continuous Continuous Continuous SAN Continuous HPS Continuous LPS MPS ST Continuous Continuous Continuous Continuous CW HWS HPW C LPS Continuous Continuous MPS Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Relocated Fire ( High Pressure Water Line) Text Relocated Fuel Line Relocated Fuel Text Relocated Gas Line Relocated Gas Text Relocated Hydrants Relocated Hydrants Text Relocated Notes And Annotation Relocated Sanitary Sewer Manholes Relocated Sanitary Sewer Manholes Text Relocated Sanitary Sewer Relocated Sanitary Sewer Text Relocated High Pressure Steam Line Relocated Steam Text Relocated Low Pressure Steam Line Relocated Medium Pressure Steam Line Relocated Storm Drainage Line Relocated Storm Drainage Catch Basins Relocated Storm Drainage Manholes Relocated Storm Drainage Text Relocated Sub-Drain Relocated Cold Water Line Relocated Hot Water Line Relocated High Pressure Water Line Relocated Water Text Relocated Low Pressure Water Line Relocated Utility Dimensions Relocated Utility Coordinate Geometry Relocated Medium Pressure Water Line

6.18.2.5
Discipline Minor Major

REMOVAL WORK
Linetype Phase Color Plots Desc

Description

Default Removal Layer Properties (Unless Otherwise Noted Below) C ____ ____ ____ RMVL 253 Continuous Yes Alignment C ALGN TRAK RR Yes ____ RMVL 253 C ALGN TRAK RR Yes ____ RMVL 253 C ALGN TRAK RR Yes ____ RMVL 253 C ALGN TRAK RR Yes ____ RMVL 253 Paving C PAVE ASPH 1 Continuous Yes ____ RMVL C PAVE BRDR 1 Continuous Yes ____ RMVL C PAVE CONC 1 Continuous Yes ____ RMVL Site Plans C SITE TICK 7 Continuous Yes ____ RMVL Utilities C UTIL FIRE HPW Yes ____ RMVL 253

Removal Track Alignment Removal Gauge Line, Track Removal Point Of Switch Removal Top Of Rail Removal Road, Parking Lot And Airside Removal Pavement Hatch Borders Removal Road, Parking Lot And Airside Removal Tick Marks Removal Fire ( High Pressure Water Line)

Last Updated: March 2010

Page 93

Engineering Department Manual


E/A Design Division CAD Standard
C C C C C C C C C C C C C UTIL UTIL UTIL UTIL UTIL UTIL UTIL UTIL UTIL UTIL UTIL UTIL UTIL FUEL GASL SSWR STEM STEM STEM STRM WATR WATR WATR WATR WATR WATR ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL 253 253 253 253 253 253 253 253 253 253 253 253 253 FOS G SAN HPS LPS MPS ST CW HWS HPW C LPS MPS Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Removal Fuel Line Removal Gas Line Removal Sanitary Sewer Removal High Pressure Steam Line Removal Low Pressure Steam Line Removal Medium Pressure Steam Line Removal Storm Drainage Line Removal Cold Water Line Removal Hot Water Line Removal High Pressure Water Line Removal Water Text Removal Low Pressure Water Line Removal Medium Pressure Water Line

6.18.2.6
Discipline Minor Major

TEMPORARY WORK
Linetype Phase Color Plots Desc

Description

Default Temporary Layer Properties (Unless Otherwise Noted Below) C ____ ____ ____ TEMP Continuous Yes Alignment C ALGN PROP ____ Phantom2 Yes TEMP 253 C ALGN ROWL ____ Phantom Yes TEMP 253 C ALGN TRAK ____ RR Yes TEMP 253 C ALGN TRAK ____ RR Yes TEMP 253 C ALGN TRAK ____ RR Yes TEMP 253 C ALGN TRAK ____ 253 RR Yes TEMP Utilities C UTIL FIRE ____ HPW Yes TEMP 253 C UTIL FUEL ____ FOS Yes TEMP 253 C UTIL GASL ____ G Yes TEMP 253 C UTIL SSWR ____ SAN Yes TEMP 253 C UTIL STEM ____ HPS Yes TEMP 253 C UTIL STEM ____ LPS Yes TEMP 253 C UTIL STEM ____ MPS Yes TEMP 253 C UTIL STRM ____ ST Yes TEMP 253 C UTIL WATR ____ CW Yes TEMP 253 C UTIL WATR ____ HWS Yes TEMP 253 C UTIL WATR ____ HPW Yes TEMP 253 C UTIL WATR ____ C Yes TEMP 253 C UTIL WATR ____ LPS Yes TEMP 253 C UTIL WATR ____ MPS Yes TEMP 253

Temporary Property Lines And Text Temporary Right Of Way Lines And Text Temporary Track Alignment Temporary Gauge Line, Track Temporary Point Of Switch Temporary Top Of Rail Temporary Fire ( High Pressure Water Line) Temporary Fuel Line Temporary Gas Line Temporary Sanitary Sewer Temporary High Pressure Steam Line Temporary Low Pressure Steam Line Temporary Medium Pressure Steam Line Temporary Storm Drainage Line Temporary Cold Water Line Temporary Hot Water Line Temporary High Pressure Water Line Temporary Water Text Temporary Low Pressure Water Line Temporary Medium Pressure Water Line

Last Updated: March 2010

Page 94

Engineering Department Manual


E/A Design Division CAD Standard

6.18.3 LINETYPES Name


C Continuous CW DASHED Description Communication Line (1x) Continuous Cold Water Line (1x) Dashed (1x) Example

DIVIDE FOS G HPS HPW HWS LPS MPS

Divide (1x) Fuel Line (1x) Gas Line (1) High Pressure Steam Line (1x) High Pressure Water Line (1x) Hot Water Line (1x) Low Pressure Water Line (1x) Medium Pressure Water Line (1x) Phantom (1x)

PHANTOM

PHANTOM2 RR SAN ST

Phantom (0.5x) Rail Road (1x) Sanitary Sewer Line (1x) Storm Drainage Line (1x)

Last Updated: March 2010

Page 95

Engineering Department Manual


E/A Design Division CAD Standard

6.18.4 SYMBOLS 6.18.4.1 DRAFTING CONVENTIONS


Symbol Block Name civ-CALLOUT.dwg Layer Name Varies Description Callout for Plans

civ-DET-SYMB.dwg

Varies

Detail Symbol for Plans

CS_CURVE.dwg

C-ALGN-CRVE

Curve Number Label

CS_FG-POINT.dwg

C-GRAD-SPOT

Finished Grade Spot Elevation

CS_GRID.dwg

C-ANNO-COGOGRID

Cogo Grid Tick

CS_PC.dwg

C-ALGN-CRVE

Bubble

CS_PITO.dwg

C-ALGN-CRVE

Revision Triangle

CS_PS.dwg

C-ALGN-CRVE

Grid Bubble

CS_REMTIC.dwg

C-RMVL-TICK

Removal Tic

CS_SECMARK1.dwg

C-PAVE-SECT

Section Marker for Plans

CS_SECMARK2.dwg

C-PAVE-SECT

Section Marker for Plans

CS_TWEDMKR.dwg

C-MARK-AIRS

Taxiway Edge Marker

Last Updated: March 2010

Page 96

Engineering Department Manual


E/A Design Division CAD Standard

FG-POINT.dwg

C-GRAD-SPOT

Finished Grade Spot Elevation

POINT (old).DWG

C-GRAD-SPOT

Finished Grade Spot Elevation (Old)

Sec1.dwg

C-ANNO-SYMB

Section, Detail, Elev. Callout

Sec2.dwg

C-ANNO-SYMB

Section, Detail, Elev. Callout

Sec3.dwg

C-ANNO-SYMB

Section, Detail, Elev. Callout

Sec4.dwg

C-ANNO-SYMB

Section, Detail, Elev. Callout

Sec5.dwg

C-ANNO-SYMB

Section, Detail, Elev. Callout

Sec6.dwg

C-ANNO-SYMB

Section, Detail, Elev. Callout

Sec7.dwg

C-ANNO-SYMB

Section, Detail, Elev. Callout

Sec8.dwg

C-ANNO-SYMB

Section, Detail, Elev. Callout

Section Title.dwg

C-ANNO-SYMB

Section Title

6.18.4.2

UTILITIES
Symbol Block Name CS_CB.dwg Layer Name C-UTIL-CBSN Description Catch Basin

Last Updated: March 2010

Page 97

Engineering Department Manual


E/A Design Division CAD Standard

CS-CBADJ.dwg

C-UTIL-CBSN

Adjust Existing Catch Basin

CS_CB-MH.dwg

C-UTIL-MANH

Convert Existing Catch Basin to Manhole

CS_EBOX.dwg

C-UTIL-MANH

Adjusted Electrical Box/Hand Hole

CS_FLOW.dwg

(Layer is Same as it is for Utility Pipe)

Flow Arrow

CS_HYD.dwg

C-UTIL-HYDR

Utility Hydrant

CS_MH.dwg

C-UTIL-MANH

Manhole

CS_MGADJ.dwg

C-UTIL-MANH

Adjust Existing Manhole

CS_PIPEPLUG.dwg

C-UTIL-STRM

Pipe Plug

CS_VALVE.dwg

(Layer is Same as it is for Utility Pipe)

Utility Line Valve

Last Updated: March 2010

Page 98

Engineering Department Manual


E/A Design Division CAD Standard

6.18.5 CIVIL 3D This Section Is Under Construction

Last Updated: March 2010

Page 99

Engineering Department Manual


E/A Design Division CAD Standard

6.19

APPENDIX C ELECTRICAL DISCIPLINE

6.19.1 CONTENT PREFERENCES This Section Is Under Construction

Last Updated: March 2010

Page 100

Engineering Department Manual


E/A Design Division CAD Standard

6.19.2 LAYER STRATAGEM 6.19.2.1


Discipline Minor Major

NEW WORK
Linetype Phase Color Plots Desc

Description

ANNOTATION E ANNO E ANNO E ANNO E ANNO E ANNO E ANNO E ANNO E ANNO E ANNO E ANNO DETAIL E DETL E DETL E DETL E DETL E DETL E DETL E DETL FIRE E FIRE

BUBL CHNG DIMS IDEN MLIN NPLT TEXT TITL TTLB VPRT EXTR HDWR HIDN INTR MISC PATT TEXT ALDL

142 7 7 2 142 170 2 6 130 130 6 7 8 142 7 252 2 142 40 142 3 252 200 170 2 6 2 6 142 11 6 7 8 142 7 252

Continuous Continuous Continuous Continuous MATCHLINE Continuous Continuous Continuous Continuous Continuous Continuous Continuous HIDDEN2 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Center Continuous Continuous Continuous Continuous Continuous Whip Continuous Continuous HIDDEN2 Continuous Continuous Continuous

Yes Yes Yes Yes Yes No Yes Yes Yes No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

Revision Bubble Identification of Updated Work Dimensions Identification Text Match Lines Construction and Reference Lines Annotations and Callouts Titles Contract Border View Port Exterior Detail Lines Hardware Detail Lines Hidden Detail Lines Interior Detail Lines Miscellaneous Detail Lines Detail Hatches Detail Annotations ALDL Devices - Smoke Detectors and Other Input Devices Fire System Speaker Fire System Strobes General Features General Background Features General Details Enclosures Identification Tags Corrosion Protection Features Corrosion Protection Annotations Light Fixtures Site Lighting Fixture Whip Connections Exterior Features Hardware Features Hidden Features Interior Features Miscellaneous Lines Lighting Hatches

E FIRE SPKR E FIRE STRB GENERAL E GNRL E GNRL BKGD E GNRL DETL E GNRL ENCL E GNRL IDEN CORROSION PROTECTION E CATH E CATH TEXT LIGHT E LITE FIXT E LITE SITE E LITE WHIP E LITE EXTR E LITE HDWR E LITE HIDN E LITE INTR E LITE MISC E LITE PATT

Last Updated: March 2010

Page 101

Engineering Department Manual


E/A Design Division CAD Standard
E LITE TEXT POWER E POWR CIRC E POWR CIRC E POWR DEVC E POWR DUCT UNDERGROUND E UGND 13KV E UGND 27KV E UGND OUTS E UGND COMM E UGND DEVC E UGND FIBR E UGND FIRE E UGND GRND E UGND PCOM E UGND POWR E UGND PSEG E UGND WIRE E UGND COMM E UGND POWR 2 3 3 142 200 7 7 7 3 142 3 142 3 3 142 7 20 7 7 Continuous Continuous HTRACE Continuous Center 13.8KV 27KV OS UGC Continuous FO FA GND PC P PSEG Continuous UGC UGE Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Lighting Annotations Conduit and Wiring Heat Trace Electrical Devices Under Floor Duct Underground 13KV Ductbank Underground 27KV Ductbank Underground Out of Service Items Underground Communication Underground Device Underground Fiber Optic Underground Fire Underground Ground Conductor Underground Power Communication Underground Power Underground PSE&G Ductbank Underground Wire Underground Communication Ductbank Underground Power Ductbank

6.19.2.2
Discipline Minor Major

EXISTING WORK
Linetype Phase Color Plots Desc

Description

Default Existing Layer Properties (Unless Otherwise Noted Below) E ____ ____ ____ EXST 253 Dashed Yes ANNOTATION E ANNO TEXT ____ EXST 2 Continuous Yes E ANNO DIMS ____ EXST 7 Continuous Yes E ANNO IDEN ____ EXST 2 Continuous Yes DETAIL E DETL EXTR ____ EXST 7 Continuous Yes E DETL HDWR ____ EXST 7 Continuous Yes E DETL HIDN ____ EXST 7 HIDDEN2 Yes E DETL INTR ____ EXST 7 Continuous Yes E DETL MISC ____ EXST 7 Continuous Yes E DETL PATT ____ EXST 252 Continuous Yes E DETL TEXT ____ EXST 2 Continuous Yes FIRE E FIRE ALDL SPKR STRB ____ ____ ____ ____ ____ ____ ____ EXST EXST EXST EXST EXST EXST EXST 7 7 7 7 7 7 2 Continuous Continuous Continuous Continuous Continuous Center Continuous Yes Yes Yes Yes Yes Yes Yes

Existing Annotations And Callouts Existing Dimensions Existing Identification Text Existing Exterior Detail Lines Existing Hardware Detail Lines Existing Hidden Detail Lines Existing Interior Detail Lines Existing Miscellaneous Detail Lines Existing Detail Hatches Existing Detail Annotations Existing Aldl Devices - Smoke Detectors And Other Input Devices Existing Fire System Speaker Existing Fire System Strobes Existing General Features Existing General Details Existing Enclosures Existing Identification Tags

E FIRE E FIRE GENERAL E GNRL E GNRL E GNRL E GNRL

DETL ENCL IDEN

Last Updated: March 2010

Page 102

Engineering Department Manual


E/A Design Division CAD Standard
CORROSION PROTECTION E CATH ____ E CATH TEXT ____ LIGHT E LITE FIXT ____ E LITE SITE ____ E LITE WHIP ____ E LITE EXTR ____ E LITE HDWR ____ E LITE HIDN ____ E LITE INTR ____ E LITE MISC ____ E LITE PATT ____ E LITE TEXT ____ POWER E POWR CIRC ____ E POWR CIRC ____ E POWR DEVC ____ E POWR DUCT ____ UNDERGROUND E UGND 13KV ____ E UGND 27KV ____ E UGND OUTS ____ E UGND COMM ____ E UGND DEVC ____ E UGND FIBR ____ E UGND FIRE ____ E UGND GRND ____ E UGND PCOM ____ E UGND POWR ____ E UGND PSEG ____ E UGND WIRE ____ E UGND COMM ____ E UGND POWR ____

EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST

7 2 7 7 7 7 7 7 7 7 252 2 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7

Continuous Continuous Continuous Continuous Whip Continuous Continuous HIDDEN2 Continuous Continuous Continuous Continuous Continuous HTRACE Continuous Center 13.8KV 27KV OS UGC Continuous FO FA GND PC P PSEG Continuous UGC UGE

Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

Existing Corrosion Protection Features Existing Corrosion Protection Annotations Existing Light Fixtures Existing Site Lighting Existing Fixture Whip Connections Existing Exterior Features Existing Hardware Features Existing Hidden Features Existing Interior Features Existing Miscellaneous Lines Existing Lighting Hatches Existing Lighting Annotations Existing Conduit And Wiring Existing Heat Trace Existing Electrical Devices Existing Under Floor Duct Existing Underground 13Kv Ductbank Existing Underground 27Kv Ductbank Existing Underground Out Of Service Items Existing Underground Communication Existing Underground Device Existing Underground Fiber Optic Existing Underground Fire Existing Underground Ground Conductor Existing Underground Power Communication Existing Underground Power Existing Underground PSE&G Ductbank Existing Underground Wire Existing Underground Communication Ductbank Existing Underground Power Ductbank

6.19.2.3
Discipline Minor Major

FUTURE WORK
Linetype Phase Color Plots Desc

Description

Default Future Layer Properties (Unless Otherwise Noted Below) E ____ ____ ____ FUTR 6 Continuous Yes ANNOTATION E ANNO DIMS ____ FUTR 7 Continuous Yes E ANNO IDEN ____ FUTR 2 Continuous Yes E ANNO TEXT ____ FUTR 2 Continuous Yes DETAIL E DETL EXTR ____ FUTR 5 Continuous Yes E DETL HDWR ____ FUTR 5 Continuous Yes E DETL HIDN ____ FUTR 5 HIDDEN2 Yes

Future Dimensions Future Identification Text Future Annotations And Callouts Future Exterior Detail Lines Future Hardware Detail Lines Future Hidden Detail Lines

Last Updated: March 2010

Page 103

Engineering Department Manual


E/A Design Division CAD Standard
E E E E FIRE E DETL DETL DETL DETL FIRE INTR MISC PATT TEXT ALDL ____ ____ ____ ____ ____ FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR 5 5 252 2 5 5 5 5 5 5 2 5 2 5 5 5 5 5 5 5 5 252 2 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Center Continuous Continuous Continuous Continuous Continuous Whip Continuous Continuous HIDDEN2 Continuous Continuous Continuous Continuous Continuous HTRACE Continuous Center 13.8KV 27KV OS UGC Continuous FO FA GND PC P PSEG Continuous UGC UGE Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Future Interior Detail Lines Future Miscellaneous Detail Lines Future Detail Hatches Future Detail Annotations Future Aldl Devices - Smoke Detectors And Other Input Devices Future Fire System Speaker Future Fire System Strobes Future General Features Future General Details Future Enclosures Future Identification Tags Future Corrosion Protection Features Future Corrosion Protection Annotations Future Light Fixtures Future Site Lighting Future Fixture Whip Connections Future Exterior Features Future Hardware Features Future Hidden Features Future Interior Features Future Miscellaneous Lines Future Lighting Hatches Future Lighting Annotations Future Conduit And Wiring Future Heat Trace Future Electrical Devices Future Under Floor Duct Future Underground 13Kv Ductbank Future Underground 27Kv Ductbank Future Underground Out Of Service Items Future Underground Communication Future Underground Device Future Underground Fiber Optic Future Underground Fire Future Underground Ground Conductor Future Underground Power Communication Future Underground Power Future Underground Pse&G Ductbank Future Underground Wire Future Underground Communication Ductbank Future Underground Power Ductbank

E FIRE SPKR ____ E FIRE STRB ____ GENERAL E GNRL ____ E GNRL DETL ____ E GNRL ENCL ____ E GNRL IDEN ____ CORROSION PROTECTION E CATH ____ E CATH TEXT ____ LIGHT E LITE FIXT ____ E LITE SITE ____ E LITE WHIP ____ E LITE EXTR ____ E LITE HDWR ____ E LITE HIDN ____ E LITE INTR ____ E LITE MISC ____ E LITE PATT ____ E LITE TEXT ____ POWER E POWR CIRC ____ E POWR CIRC ____ E POWR DEVC ____ E POWR DUCT ____ UNDERGROUND E UGND 13KV ____ E UGND 27KV ____ E UGND OUTS ____ E UGND COMM ____ E UGND DEVC ____ E UGND FIBR ____ E UGND FIRE ____ E UGND GRND ____ E UGND PCOM ____ E UGND POWR ____ E UGND PSEG ____ E UGND WIRE ____ E UGND COMM ____ E UGND POWR ____

Last Updated: March 2010

Page 104

Engineering Department Manual


E/A Design Division CAD Standard 6.19.2.4
Discipline Minor Major

RELOCATED WORK
Linetype Phase Color Plots Desc

Description

Default Relocated Layer Properties (Unless Otherwise Noted Below) E ____ ____ ____ RELO 6 Continuous ANNOTATION E ANNO BUBL ____ RELO 142 Continuous E ANNO CHNG ____ RELO 7 Continuous E ANNO DIMS ____ RELO 7 Continuous E ANNO IDEN ____ RELO 2 Continuous E ANNO MLIN ____ RELO 142 MATCHLINE E ANNO NPLT ____ RELO 170 Continuous E ANNO TEXT ____ RELO 2 Continuous E ANNO TTLB ____ RELO 130 Continuous E ANNO VPRT ____ RELO 130 Continuous DETAIL E DETL HDWR ____ RELO 7 Continuous E DETL HIDN ____ RELO 8 HIDDEN2 E DETL INTR ____ RELO 142 Continuous E DETL MISC ____ RELO 7 Continuous E DETL PATT ____ RELO 252 Continuous E DETL TEXT ____ RELO 2 Continuous FIRE E FIRE ALDL ____ RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO 142 40 142 3 252 200 170 2 6 2 142 11 7 8 142 7 252 2 3 3 142 Continuous Continuous Continuous Continuous Continuous Continuous Center Continuous Continuous Continuous Continuous Whip Continuous HIDDEN2 Continuous Continuous Continuous Continuous Continuous HTRACE Continuous

Yes Yes Yes Yes Yes Yes No Yes Yes No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Relocate Revision Bubble Relocate Identification of Updated Work Relocate Dimensions Relocate Identification Text Relocate Match Lines Relocate Construction and Reference Lines Relocate Annotations and Callouts Relocate Contract Border Relocate View Port Relocate Hardware Detail Lines Relocate Hidden Detail Lines Relocate Interior Detail Lines Relocate Miscellaneous Detail Lines Relocate Detail Hatches Relocate Detail Annotations Relocate ALDL Devices - Smoke Detectors and Other Input Devices Relocate Fire System Speaker Relocate Fire System Strobes Relocate General Features Relocate General Background Features Relocate General Details Relocate Enclosures Relocate Identification Tags Relocate Corrosion Protection Features Relocate Corrosion Protection Annotations Relocate Site Lighting Relocate Fixture Whip Connections Relocate Hardware Features Relocate Hidden Features Relocate Interior Features Relocate Miscellaneous Lines Relocate Lighting Hatches Relocate Lighting Annotations Relocate Conduit and Wiring Relocate Heat Trace Relocate Electrical Devices

E FIRE SPKR ____ E FIRE STRB ____ GENERAL E GNRL ____ E GNRL BKGD ____ E GNRL DETL ____ E GNRL ENCL ____ E GNRL IDEN ____ CORROSION PROTECTION E CATH ____ E CATH TEXT ____ LIGHT E LITE SITE ____ E LITE WHIP ____ E LITE HDWR ____ E LITE HIDN ____ E LITE INTR ____ E LITE MISC ____ E LITE PATT ____ E LITE TEXT ____ POWER E POWR CIRC ____ E POWR CIRC ____ E POWR DEVC ____

Last Updated: March 2010

Page 105

Engineering Department Manual


E/A Design Division CAD Standard
E POWR DUCT UNDERGROUND E UGND 13KV E UGND 27KV E UGND OUTS E UGND COMM E UGND DEVC E UGND FIBR E UGND FIRE E UGND GRND E UGND PCOM E UGND POWR E UGND PSEG E UGND WIRE E UGND COMM E UGND POWR ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO 200 7 7 7 3 142 3 142 3 3 142 7 20 7 7 Center 13.8KV 27KV OS UGC Continuous FO FA GND PC P PSEG Continuous UGC UGE Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Relocate Under Floor Duct Relocate Underground 13KV Ductbank Relocate Underground 27KV Ductbank Relocate Underground Out of Service Items Relocate Underground Communication Relocate Underground Device Relocate Underground Fiber Optic Relocate Underground Fire Relocate Underground Ground Conductor Relocate Underground Power Communication Relocate Underground Power Relocate Underground PSE&G Ductbank Relocate Underground Wire Relocate Underground Communication Ductbank Relocate Underground Power Ductbank

6.19.2.5
Discipline Minor Major

TEMPORARY WORK
Linetype Phase Color Plots Desc

Description

Default Temporary Layer Properties (Unless Otherwise Noted Below) E ____ ____ ____ TEMP 6 Continuous Yes ANNOTATION E ANNO DIMS ____ TEMP 7 Continuous Yes E ANNO IDEN ____ TEMP 2 Continuous Yes E ANNO TEXT ____ TEMP 2 Continuous Yes DETAIL E DETL EXTR ____ TEMP 8 Continuous Yes E DETL HDWR ____ TEMP 8 Continuous Yes E DETL HIDN ____ TEMP 8 HIDDEN2 Yes E DETL INTR ____ TEMP 8 Continuous Yes E DETL MISC ____ TEMP 8 Continuous Yes E DETL PATT ____ TEMP 252 Continuous Yes E DETL TEXT ____ TEMP 2 Continuous Yes FIRE E FIRE ALDL ____ TEMP TEMP TEMP TEMP TEMP TEMP TEMP TEMP TEMP TEMP 8 8 8 8 8 8 2 8 2 8 Continuous Continuous Continuous Continuous Continuous Center Continuous Continuous Continuous Continuous Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

Temporary Dimensions Temporary Identification Text Temporary Annotations And Callouts Temporary Exterior Detail Lines Temporary Hardware Detail Lines Temporary Hidden Detail Lines Temporary Interior Detail Lines Temporary Miscellaneous Detail Lines Temporary Detail Hatches Temporary Detail Annotations Temporary Aldl Devices - Smoke Detectors And Other Input Devices Temporary Fire System Speaker Temporary Fire System Strobes Temporary General Features Temporary General Details Temporary Enclosures Temporary Identification Tags Temporary Corrosion Protection Features Temporary Corrosion Protection Annotations Temporary Light Fixtures

E FIRE SPKR ____ E FIRE STRB ____ GENERAL E GNRL ____ E GNRL DETL ____ E GNRL ENCL ____ E GNRL IDEN ____ CORROSION PROTECTION E CATH ____ E CATH TEXT ____ LIGHT E LITE FIXT ____

Last Updated: March 2010

Page 106

Engineering Department Manual


E/A Design Division CAD Standard
E LITE SITE E LITE WHIP E LITE EXTR E LITE HDWR E LITE HIDN E LITE INTR E LITE MISC E LITE PATT E LITE TEXT POWER E POWR CIRC E POWR CIRC E POWR DEVC E POWR DUCT UNDERGROUND E UGND 13KV E UGND 27KV E UGND OUTS E UGND COMM E UGND DEVC E UGND FIBR E UGND FIRE E UGND GRND E UGND PCOM E UGND POWR E UGND PSEG E UGND WIRE E UGND COMM E UGND POWR ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ TEMP TEMP TEMP TEMP TEMP TEMP TEMP TEMP TEMP TEMP TEMP TEMP TEMP TEMP TEMP TEMP TEMP TEMP TEMP TEMP TEMP TEMP TEMP TEMP TEMP TEMP TEMP 8 8 8 8 8 8 8 252 2 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 Continuous Whip Continuous Continuous HIDDEN2 Continuous Continuous Continuous Continuous Continuous HTRACE Continuous Center 13.8KV 27KV OS UGC Continuous FO FA GND PC P PSEG Continuous UGC UGE Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Temporary Site Lighting Temporary Fixture Whip Connections Temporary Exterior Features Temporary Hardware Features Temporary Hidden Features Temporary Interior Features Temporary Miscellaneous Lines Temporary Lighting Hatches Temporary Lighting Annotations Temporary Conduit And Wiring Temporary Heat Trace Temporary Electrical Devices Temporary Under Floor Duct Temporary Underground 13Kv Ductbank Temporary Underground 27Kv Ductbank Temporary Underground Out Of Service Items Temporary Underground Communication Temporary Underground Device Temporary Underground Fiber Optic Temporary Underground Fire Temporary Underground Ground Conductor Temporary Underground Power Communication Temporary Underground Power Temporary Underground Pse&G Ductbank Temporary Underground Wire Temporary Underground Communication Ductbank Temporary Underground Power Ductbank

Last Updated: March 2010

Page 107

Engineering Department Manual


E/A Design Division CAD Standard

6.19.3 LINETYPES Name


Continuous Description Continuous Example

DASHED

Dashed (1x)

DIVIDE

Divide (1x)

Last Updated: March 2010

Page 108

Engineering Department Manual


E/A Design Division CAD Standard

6.19.4 SYMBOLS 6.19.4.1 BLOCK DIAGRAMS


Symbol Block Name TSS001.dwg Layer Name E-LITE-SITE Description Overhead Sign Structure

TSS002.dwg

E-GNRL-EXST

Overhead Sign Structure Existing to Remain

TSS04.dwg

E-LITE-SITE

Ground-Mounted Sign Structure

TSS05.dwg

E-GNRL-EXST

Ground-Mounted Sign Structure Existing to Remain

TSS07.dwg

E-GNRL-DETL

Sign Structure Identifier

TSS08.dwg

E-LITE-SITE

Traffic Signal Standard

TSS09.dwg

E-GNRL-EXST

Traffic Signal Standard Existing to Remain

TSS11.dwg

E-LITE-SITE

Traffic Signal Post Top-Mounted

TSS12.dwg

E-GNRL-EXST

Traffic Signal Post Top-Mounted Existing to Remain

TSS14.dwg

E-LITE-SITE

Vehicular Traffic Signal Head

TSS15.dwg

E-POWR-DEVC

Traffic Signal Control Cabinet

TSS15_1.dwg

E-POWR-DEVC

Traffic Signal Control Cabinet

Last Updated: March 2010

Page 109

Engineering Department Manual


E/A Design Division CAD Standard

TSS15_2.dwg

E-GNRL-DETL

Cabinet Identification

TSS16.dwg

E-GNRL-EXST

Traffic Signal Control Cabinet Existing to Remain

TSS18.dwg

E-POWR-DEVC

Variable Message Sign Control Cabinet

TSS19.dwg

E-GNRL-EXST

Variable Message Sign Control Cabinet Existing to Remain

IR007.dwg

E-GNRL-DETL

Transformer Fault Pressure Relay

IR015.dwg

E-POWR-CIRC

Breaker Control Switch

6.19.4.2

FIRE
Symbol Block Name FAS001.dwg Layer Name E-FIRE-ALDL Description Ceiling Mounted Smoke Detector

FAS001H.dwg

E-FIRE-ALDL

Heat Detector

FAS002.dwg

E-FIRE-ALDL

Duct Detector

FAS003.dwg

E-FIRE-ALDL

Duct Detector (With Line Segment)

FAS004.dwg

E-FIRE-STRB

Fire Alarm Strobe

FAS004a.dwg

E-FIRE-ALDL

Fire Damper

Last Updated: March 2010

Page 110

Engineering Department Manual


E/A Design Division CAD Standard

FAS005.dwg

E-FIRE-STRB

Fire Alarm Strobe/Speaker

FAS005H.dwg

E-FIRE-STRB

Fire Strobe

FAS006.dwg

E-FIRE-SPKR

Fire Alarm Speaker CeilingMounted

FAS007.dwg

E-FIRE-SPKR

Fire Alarm Speaker WallMounted

FAS008.dwg

E-ANNO-TEXT

End of Line

FAS009.dwg

E-FIRE-ALDL

Fire Alarm Pull Station

FAS010.dwg

E-FIRE-ALDL

Flow Switch

FAS011.dwg

E-FIRE-ALDL

Tamper Switch

FAS012.dwg

E-FIRE-ALDL

Warden Phone

FAS012_1.dwg

E-FIRE-ALDL

Warden Phone

FAS013.dwg

E-FIRE-ALDL

Tri-Interface Module

FAS013_1.dwg

E-FIRE-ALDL

Tri-Dual-Interface Module

FAS013_2.dwg

E-FIRE-ALDL

Tri-Interface Module with Relay

Last Updated: March 2010

Page 111

Engineering Department Manual


E/A Design Division CAD Standard

FAS013_3.dwg

E-FIRE-ALDL

Interface Module

FAS014.dwg

E-FIRE-ALDL

Addressable Terminal Cabinet

FAS015.dwg

E-FIRE-ALDL

Tenant Fire Alarm Amplifier

FAS016.dwg

E-FIRE-ALDL

Terminal Strip Cabinet

FAS017.dwg

E-POWR-DEVC

Solenoid Valve

FAS018.dwg

E-FIRE-SPKR

Fire Alarm Horn

FAS019.dwg

E-FIRE-ALDL

Strobe

FAS020.dwg

E-POWR-DEVC

Auxiliary Power Supply

FAS021.dwg

E-FIRE-ALDL

Flow Switch

FAS022.dwg

E-FIRE-ALDL

SO

FAS023.dwg

E-POWR-DEVC

Transformer

Fas024.dwg

E-FIRE-ALDL

TIB

FS010.dwg

E-FIRE-ALDL

Flow Switch

Last Updated: March 2010

Page 112

Engineering Department Manual


E/A Design Division CAD Standard 6.19.4.3 AVIATION LIGHTING
Symbol Block Name Aer010.dwg Layer Name E-LITE-SITE Description Runway/Taxiway Light

Aer012.dwg

E-LITE-SITE

L-861-T Elevated Blue Taxiway Edge Light on Type I Marker Light Box Existing Elevated Blue Taxiway Edge Light to be Adjusted to Finished Grade Existing Runway/Taxiway Elevated Edge Light on Type I Marker Light Box L-852 Type IV Flush Taxiway Centerline Light Fed by Flexible Conduit in Existing Pavement L-852 Type IV Flush Taxiway Centerline Light Fed by Encased PVC Conduit L-852 Type IV Flush Taxiway Centerline Light Mounted on a L868 Double Section Base Can Fed by Grout Encased PVC-H Conduit in Pavement Existing Type IV Taxiway Centerline Lighting Fixture to be Adjusted to Finished Grade via a Variable Extension Can Omni-Directional Fixture Mounted on a L-868 Single Section Base Can in Existing or Overlay Pavement L-861-T Elevated Taxiway Edge Light Mounted on a L-867 Single Section Base Can

Aer013.dwg

E-GNRL-EXST

Aer014.dwg

E-GNRL-EXST

Aer015.dwg

E-LITE-SITE

Aer016.dwg

E-LITE-SITE

Aer017.dwg

E-LITE-SITE

Aer019.dwg

E-GNRL-EXST

Aer020.dwg

E-LITE-SITE

Aer021.dwg

E-LITE-SITE

Aer021_1.dwg

E-LITE-SITE

Centerline Light

Aer022.dwg

E-GNRL-EXST

Existing L-861-T Elevated Taxiway Edge Light Mounted on a L-867 Single Section Base Can

Last Updated: March 2010

Page 113

Engineering Department Manual


E/A Design Division CAD Standard
Adjust L-861-T Elevated Taxiway Edge Light Mounted on a L-867 Single Section Base Can to Finished Grade Internally-Illuminated Single-Face Taxiway

Aer023.dwg

E-LITE-SITE

AER024.DWG

E-LITE-SITE

AER024_1.DWG

E-LITE-SITE

The Sign Number

AER024_2.DWG

E-GNRL-DETL

The Sign Number 2

AER025.DWG

E-LITE-SITE

Internally Illuminated Double Face Taxiway Guidance Sign

Aer026.dwg

E-POWR-DEVC

Elevated Retroreflective Taxiway Marker

AER027.DWG

E-LITE-SITE

High-Intensity Hold Bar

Aer028.dwg

E-LITE-SITE

L-850C Flush Runway Edge Light Mounted on a L-868 SingleSection Base Can

Aer034.dwg

E-LITE-SITE

Runway/Taxiway Fixture

AER035.DWG

E-GNRL-EXST

Existing Electrical Communication Manhole

Aer037.dwg

E-GNRL-EXST

Existing Flush Taxiway or Runway Centerline Fixture to Remain

Aer038.dwg

E-GNRL-EXST

Existing Flush Runway Edge Light

AER040.DWG

E-GNRL-EXST

Existing Internally-Illuminated Single-Face Taxiway Guidance Sign

Last Updated: March 2010

Page 114

Engineering Department Manual


E/A Design Division CAD Standard

Aer041.dwg

E-GNRL-EXST

Existing Flush Taxiway Omnidirectional Fixture

AER042.DWG

E-GNRL-EXST

Existing Flush Taxiway Omnidirectional Fixture Removal Existing Type I Marker Light Box, Including Fixture, Transformers, and Base Plates Removals Existing Taxiway Centerline Fixture Removal

AER043.DWG

E-GNRL-RMVL

AER044.DWG

E-GNRL-RMVL

AER050.DWG

E-GNRL-DETL

Number Designation for CrossReferences with Wiring Diagram

Aer051.dwg

E-UGND-DEVC

Splice Box for Sensor Cable

AER053.DWG

E-UGND-DEVC

Existing Runway Surface Sensor to be Replaced

Aer055.dwg

E-GNRL-EXST

Existing Double-Obstruction Light

Aer056.dwg

E-GNRL-EXST

Existing Single-Obstruction Light

Aer057.dwg

E-LITE-SITE

L-810 Double-Obstruction Light

Aer058.dwg

E-LITE-SITE

L-810 Single-Obstruction Light

Aer059.dwg

E-POWR-DEVC

Wind Cone

Aer060.dwg

E-LITE-SITE

Flush Approach Light Bar by the FAA

Last Updated: March 2010

Page 115

Engineering Department Manual


E/A Design Division CAD Standard

Aer061.dwg

E-LITE-SITE

Runway Touchdown Zone Light Bar Adjust the Existing InternallyIlluminated Single-Face Taxiway Guidance Sign and Foundation to Finished Grade Existing Internally-Illuminated Double-Face Taxiway Guidance Sign Adjust the Existing InternallyIlluminated Double-Face Taxiway Guidance Sign and Foundation to Finished Grade

AER064.DWG

E-LITE-SITE

AER067.DWG

E-GNRL-EXST

AER068.DWG

E-LITE-SITE

6.19.4.4

LIGHTING FIXTURES
Symbol Block Name LTG001.DWG Layer Name E-LITE-FIXT Description Ceiling-Mounted 1x4 Fluorescent Lighting Fixture

LTG002.DWG

E-LITE-FIXT

Ceiling-Mounted 1x4 Emergency Fluorescent Lighting Fixture Ceiling-Mounted 1x4 Fluorescent Fixture with Internal Emergency Battery Wall-Mounted 1x4 Fluorescent Fixture

LTG003.DWG

E-LITE-FIXT

LTG004.DWG

E-LITE-FIXT

LTG005.DWG

E-LITE-FIXT

Wall-Mounted 1x4 Fluorescent Fixture Wall-Mounted 1x4Fluorescent Fixture with Internal Emergency Battery Ceiling-Mounted 1x8 Fluorescent Fixture

LTG006.DWG

E-LITE-FIXT

LTG007.DWG

E-LITE-FIXT

LTG008.DWG

E-LITE-FIXT

Ceiling-Mounted Emergency Fluorescent Fixture

Last Updated: March 2010

Page 116

Engineering Department Manual


E/A Design Division CAD Standard
Ceiling-Mounted Fluorescent Fixture with Internal Emergency Battery Ceiling-Mounted Continuous Fluorescent Fixture

LTG009.DWG

E-LITE-FIXT

LTG010.DWG

E-LITE-FIXT

LTG011.DWG

E-LITE-FIXT

Ceiling-Mounted Continuous Fluorescent Slot Washer

LTG012.DWG

E-LITE-FIXT

Ceiling-Mounted 2x4 Fluorescent Fixture

LTG013.DWG

E-LITE-FIXT

Ceiling-Mounted 2x4 Emergency Fluorescent Fixture Ceiling-Mounted Fluorescent Fixture with Internal Emergency Battery Ceiling-Mounted 2x2 Fluorescent Fixture

LTG014.DWG

E-LITE-FIXT

LTG015.DWG

E-LITE-FIXT

LTG016.DWG

E-LITE-FIXT

Ceiling-Mounted 2x2 Emergency Fluorescent Fixture Ceiling-Mounted 2x2 Fluorescent Fixture with Internal Emergency Battery Ceiling-Mounted 1x2 Fluorescent Fixture

LTG017.DWG

E-LITE-FIXT

LTG018.DWG

E-LITE-FIXT

LTG019.DWG

E-LITE-FIXT

Ceiling-Mounted 1x2 Fluorescent Wall Washer

LTG020.DWG

E-LITE-FIXT

Ceiling-Mounted Fluorescent Fixture

LTG021.DWG

E-LITE-FIXT

Ceiling-Mounted 1x1 Compact Fluorescent Downlight

Last Updated: March 2010

Page 117

Engineering Department Manual


E/A Design Division CAD Standard

LTG022.DWG

E-LITE-FIXT

Ceiling-Mounted 1x1 Compact Fluorescent Ceiling-Mounted 1x1 Compact Fluorescent Downlight with Internal Emergency Battery

LTG023.DWG h LTG024.DWG

E-LITE-FIXT

E-LITE-FIXT

Lighting Fixture

LTG025.DWG

E-LITE-FIXT

Recessed Lighting Fixture, Partial Exposure

LTG026.DWG

E-LITE-FIXT

Lighting Fixture

LTG027.DWG

E-LITE-FIXT

Recessed Lighting Fixture, Large

LTG028.DWG

E-LITE-FIXT

Recessed Lighting Fixture, Small

LTG029.DWG

E-LITE-FIXT

Recessed Lighting Fixture

LTG030.DWG

E-LITE-FIXT

Lighting Fixture

LTG031.DWG

E-LITE-FIXT

Lighting Fixture

LTG032.DWG

E-LITE-FIXT

Wall-Mounted Lighting Fixture

LTG033.DWG

E-LITE-FIXT

Surface-Mounted Hid Fixture

LTG034.DWG

E-LITE-FIXT

Surface-Mounted Hid Fixture 2

Last Updated: March 2010

Page 118

Engineering Department Manual


E/A Design Division CAD Standard

LTG035.DWG

E-LITE-FIXT

Fluorescent Strip

LTG036.DWG

E-LITE-FIXT

Track-Mounted Adjustable Fixtures

LTG037.DWG

E-LITE-FIXT

Emergency Batter Pack Lights

LTG038.DWG

E-LITE-FIXT

Ceiling-Mounted Exit Signs with Directional Arrow

LTG039.DWG

E-LITE-FIXT

Ceiling-Mounted Exit Signs with Directional Arrow 2

LTG040.DWG

E-LITE-FIXT

Ceiling-Mounted Exit Signs with Directional Arrow 3

LTG041.DWG

E-LITE-FIXT

Ceiling-Mounted Exit Signs with Directional Arrow 4

LTG042.DWG

E-LITE-FIXT

Wall-Mounted Outdoor Fixture

LTG043.DWG

E-LITE-FIXT

Wall-Mounted Outdoor Fixture 2

LTG044.DWG

E-LITE-FIXT

Wall-Mounted Outdoor Fixture 3

LTG045.DWG

E-LITE-FIXT

Wall-Mounted Outdoor Fixture 4

LTG046.DWG

E-LITE-FIXT

High-Mast Lighting Assembly Type

LTG047.DWG

E-LITE-FIXT

High-Mast Lighting Assembly Type 2

Last Updated: March 2010

Page 119

Engineering Department Manual


E/A Design Division CAD Standard

LTG048.DWG

E-LITE-FIXT

High-Mast Lighting Assembly Type 3

LTG049.DWG

E-LITE-FIXT

Floodlight Pole Lighting Assembly

LTG050.DWG

E-LITE-FIXT

Floodlight Pole Lighting Assembly

LTG051.DWG

E-LITE-FIXT

Single-Arm Roadway Lighting Standard

LTG052.DWG

E-LITE-FIXT

Remove Single-Arm Roadway Standard Relocated Single-Arm Roadway Lighting Standard Existing Location Relocated Single-Arm Roadway Lighting Standard New Location

LTG053.DWG

E-LITE-FIXT

LTG054.DWG

E-LITE-FIXT

LTG055.DWG

E-LITE-FIXT

Double-Arm Roadway Lighting Standard

LTG056.DWG

E-LITE-FIXT

Remove Double-Arm Roadway Lighting Standard Relocate Double-Arm Roadway Lighting Standard Existing Location Relocated Double-Arm Roadway Lighting Standard New location

LTG057.DWG

E-LITE-FIXT

LTG058.DWG

E-LITE-FIXT

LTG059.DWG

E-LITE-FIXT

Single-Arm Roadway Lighting Standard

LTG060.DWG

E-LITE-FIXT

Remove Single-Arm Roadway Lighting Standard

Last Updated: March 2010

Page 120

Engineering Department Manual


E/A Design Division CAD Standard
Relocate Single-Arm Roadway Lighting Standard Existing Location Relocated Single-Arm Roadway Lighting Standard New Location

LTG061.DWG

E-LITE-FIXT

LTG062.DWG

E-LITE-FIXT

LTG063.DWG

E-LITE-FIXT

Double-Arm Roadway Lighting Standard

LTG064.DWG

E-LITE-FIXT

Remove Double-Arm Roadway Lighting Standard Relocate Double-Arm Roadway Lighting Standard Existing Location Relocated Double-Arm Roadway Lighting Standard New Location

LTG065.DWG

E-LITE-FIXT

LTG066.DWG

E-LITE-FIXT

LTG067.DWG

E-LITE-FIXT

Single-Arm Pole-Mounted Sharp Cut-Off Luminaire

LTG068.DWG

E-LITE-FIXT

Remove Single-Arm PoleMounted Sharp Cut-Off Luminaire Relocate Single-Arm PoleMounted Sharp Cut-Off Luminaire (Existing Location) Relocated Single-Arm PoleMounted Sharp Cut-Off Luminaire (New Location) Single-Arm Pole-Mounted Sharp Cut-Off Luminaire

LTG069.DWG

E-LITE-FIXT

LTG070.DWG

E-LITE-FIXT

LTG071.DWG

E-LITE-FIXT

LTG072.DWG

E-LITE-FIXT

Remove Single-Arm PoleMounted Sharp Cut-Off Luminaire Relocate Single-Arm Pole Mounted Sharp Cut-Off Luminaire (Existing Location)

LTG073.DWG

E-LITE-FIXT

Last Updated: March 2010

Page 121

Engineering Department Manual


E/A Design Division CAD Standard

LTG074.DWG

E-LITE-FIXT

Relocated Single-Arm PoleMounted Sharp Cut-Off Luminaire

LTG075.DWG

E-LITE-FIXT

Sinle0Arm Pole-Mounted Sharp Cut-Off Luminaire

LTG076.DWG

E-LITE-FIXT

Remove Single-Arm PoleMounted Sharp Cut-Off Luminaire Relocate Single-Arm PoleMounted Sharp Cut-Off Luminaire (Existing Location) Relocated Single-Arm PoleMounted Sharp Cut-Off Luminaire (New Location) Double-Arm Pole-Mounted Sharp Cut-Off Luminaire

LTG077.DWG

E-LITE-FIXT

LTG078.DWG

E-LITE-FIXT

LTG079.DWG

E-LITE-FIXT

LTG080.DWG

E-LITE-FIXT

Remove Double-Arm PoleMounted Sharp Cut-Off Luminaire Relocate Double-Arm PoleMounted Sharp Cut-Off Luminaire (Existing Location) Relocated Double-Arm PoleMounted Sharp Cut-Off Luminaire (New Location) Double-Arm Pole-Mounted Sharp Cut-Off Luminaire

LTG081.DWG

E-LITE-FIXT

LTG082.DWG

E-LITE-FIXT

LTG083.DWG

E-LITE-FIXT

LTG084.DWG

E-LITE-FIXT

Remove Double-Arm PoleMounted Sharp Cut-Off Luminaire Relocate Double-Arm PoleMounted Sharp Cut-Off Luminaire (Existing Location) Relocated Double-Arm PoleMounted Sharp Cut-Off Luminaire (New Location)

LTG085.DWG

E-LITE-FIXT

LTG086.DWG

E-LITE-FIXT

Last Updated: March 2010

Page 122

Engineering Department Manual


E/A Design Division CAD Standard

LTG087.DWG

E-LITE-FIXT

Double-Arm Pole-Mounted Sharp Cut-Off Luminaire

LTG088.DWG

E-LITE-FIXT

Remove Double-Arm Pole Mounted Sharp Cut-Off Luminaire Relocate Double_Arm Pole Mounted Sharp Cut-Off Luminaire (Existing Location) Relocated Double-Arm PoleMounted Sharp Cut-Off Luminaire (New Location)

LTG089.DWG

E-LITE-FIXT

LTG090.DWG

E-LITE-FIXT

LTG091.DWG

E-LITE-FIXT

Yoke-Mounted HID Floodlight

LTG092.DWG

E-LITE-FIXT

Yoke-Mounted HID Floodlight 2

LTG093.DWG

E-LITE-FIXT

Yoke-Mounted HID Floodlight 3

LTG101.DWG

E-LITE-FIXT

Exit Sign Single Face

LTG102.DWG

E-LITE-FIXT

Exit Sign Single Face, Exit to West

LTG103.DWG

E-LITE-FIXT

Exit Sign Single Face, Exit to East

LTG104.DWG

E-LITE-FIXT

Exit Sign Double-Faced

LTG105.DWG

E-LITE-FIXT

Exit Sign Double-Faced, Exit to East

LTG106.DWG

E-LITE-FIXT

Wall-Mounted Exit Sign, Single Face

Last Updated: March 2010

Page 123

Engineering Department Manual


E/A Design Division CAD Standard

LTG107.DWG

E-LITE-FIXT

Wall-Mounted Exit Sign, Single Face, Exit to West

LTG108.DWG

E-LITE-FIXT

Wall-Mounted Exit Sign, Single Face, Exit to East

LTG109.DWG

E-LITE-FIXT

Wall-Mounted Exit Sign, Single Face, Double-Faced

6.19.4.5

SWITCHES
Symbol Block Name SWT001.DWG Layer Name E-POWR-DEVC Description Switch

SWT002.DWG

E-POWR-DEVC

3-Way Switch

SWT003.DWG

E-POWR-DEVC

4-Way Switch

SWT004.DWG

E-POWR-DEVC

Dimmer Switch

SWT005.DWG

E-POWR-DEVC

Switch

SWT006.DWG

E-POWR-DEVC

Switch

SWT007.DWG

E-POWR-DEVC

3-Way Dimmer Switch

SWT008.DWG

E-POWR-DEVC

Manual Motor Starting Switch with Thermal Overload Protection and Pilot Light Manual Motor Starting Switch with Thermal Overload Protection

Swt009.DWG

E-POWR-DEVC

Last Updated: March 2010

Page 124

Engineering Department Manual


E/A Design Division CAD Standard

Swt009A.DWG

E-POWR-DEVC

Switch

Swt009B.DWG

E-POWR-DEVC

Switch

Swt009C.DWG

E-POWR-DEVC

Switch

Swt009D.DWG

E-POWR-DEVC

Switch

Swt009E.DWG

E-POWR-DEVC

Switch

6.19.4.6

MISCELLANEOUS
Symbol Block Name Bubble2.dwg Layer Name E-ANNO-DIMS Description Leader Bubble

BUBBLE3.dwg

E-ANNO-DIMS

Elongated Leader Bubble

MIS011.DWG

E-RVSN-SYMB

Revision Tag

REVISION.DWG

E-ANNO-DIMS

Revision Table

Sign-p.dwg

E-ANNO-TTLB

Signature Stamp

Mis041.dwg

Circuit Breaker Panel

Mis042.dwg

Power Panel

Last Updated: March 2010

Page 125

Engineering Department Manual


E/A Design Division CAD Standard

Mis043.dwg

Circuit Breaker Panel R/C Controlled

Mis044.dwg

Distribution Panel

Mis045.dwg

Motor Control Panel

Mis057.dwg

Transformer Schedule

Mis058.dwg

Metal-Clad Switch Gear Schedule

Mis059.dwg

Medium-Voltage Interrupter Schedule

Mis060.dwg

Cable and Conduit Schedule

Mis061.dwg

Lighting Fixture Schedule

ele-DET-SYMB.dwg

(Varies)

Detail Symbol

IR001.DWG

E-POWR-CIRC

Regulating Device

IR002.DWG

E-POWR-CIRC

Kilowatt-Hour Meter

IR003.DWG

E-POWR-CIRC

Instrument Switch, Test Block or Transducer

IR004.DWG

E-POWR-CIRC

Instrument Switch, Test Block or Transducer 2

Last Updated: March 2010

Page 126

Engineering Department Manual


E/A Design Division CAD Standard

IR005.DWG

E-POWR-CIRC

Time Overcurrent Relay with Instantaneous Trip Attachment

IR006.DWG

E-POWR-CIRC

Time Overcurrent Ground Relay for All 50, 51, and 50/51 Relays.

IR007.DWG

E-POWR-CIRC

Transformer Fault Pressure Relay

IR008.DWG

E-POWR-CIRC

Transformer Sudden Pressure Relay

IR010.DWG

E-POWR-CIRC

Control Switch Trip

IR012.DWG

E-POWR-CIRC

Control Switch Remote Local

IR013.DWG

E-POWR-CIRC

Indicator Light

IR014.DWG

E-POWR-CIRC

Lamp Test Relay

IR016.DWG

E-POWR-CIRC

Scada System Indication Function

IR017.DWG

E-POWR-CIRC

Scada System Control Function

IR018.DWG

E-POWR-CIRC

Solid-State Metering

IR019.DWG

E-POWR-CIRC

Annunciator

IR020.DWG

E-POWR-CIRC

Instrument

Last Updated: March 2010

Page 127

Engineering Department Manual


E/A Design Division CAD Standard

IR021.DWG

E-POWR-CIRC

Instrument

MIS001.DWG

E-GNRL-DETL

Equipment Designation

MIS004.DWG

E-POWR-DEVC

Pull Box

MIS005.DWG

E-POWR-DEVC

Push Button

MIS006.DWG

E-POWR-DEVC

Closed-Circuit TV Camera

MIS007.DWG

E-POWR-DEVC

Closed-Circuit TV Camera 2

MIS008.DWG

E-POWR-DEVC

Special System Device

MIS010.DWG

E-POWR-DEVC

Aqua Stat

MIS012.DWG

E-GNRL-DETL

Circle or Column Tag

MIS013.DWG

E-GNRL-DETL

Section Arrows

MIS023.DWG

E-POWR-DEVC

Break Glass Station

MIS024.DWG

E-POWR-DEVC

Electromagnetic Door Holder

Mis035.dwg

E-ANNO-DIMS

Arrowhead

Last Updated: March 2010

Page 128

Engineering Department Manual


E/A Design Division CAD Standard

Mis036.dwg

E-POWR-CIRC

Conduit/Line Break

Mis037.dwg

E-ANNO-DIMS

Bracket

Mis049.dwg

E-GNRL-DETL

Section

Mis050.dwg

E-ANNO-TTLB

Preliminary Stamp

Mis051.dwg

E-ANNO-TTLB

Submission Stamp

Mis052.dwg

E-ANNO-TTLB

As-Built Stamp

Mis053.dwg

E-GNRL-CIRC

Conduit Break

Mis056.dwg

E-GNRL-DETL

Section Title

MIS070.DWG

E-POWR-DEVC

TVSS

MIS071.DWG

E-POWR-DEVC

Reflector

WALLBREAK.dwg

E-GNRL-DETL

Wall Break

6.19.4.7

ONE LINE
Symbol Block Name CDS001.DWG Layer Name E-POWR-CIRC Description Instantaneous Contact, NO

Last Updated: March 2010

Page 129

Engineering Department Manual


E/A Design Division CAD Standard

CDS002.DWG

E-POWR-CIRC

Instantaneous Contact, NC

CDS003.DWG

E-POWR-CIRC

On Delay Timer Contact, NO Time Open

CDS004.DWG

E-POWR-CIRC

On Delay Timer Contact, NC Time Open

CDS005.DWG

E-POWR-CIRC

Off Delay Timer Contact, NO Time Open

CDS006.DWG

E-POWR-CIRC

Off Delay Timer Contact, NC Time Closed

CDS007.DWG

E-POWR-CIRC

Limit Switch Contact, NO

CDS008.DWG

E-POWR-CIRC

Limit Switch Contact, NC

CDS009.DWG

E-POWR-CIRC

Limit Switch Contact NO Held Closed

CDS010.DWG

E-POWR-CIRC

Limit Switch Contact NC Held Open

CDS011.DWG

E-POWR-CIRC

Momentary Contact Push Button, NO

CDS012.DWG

E-POWR-CIRC

Momentary Contact Push Button, NC

CDS013.DWG

E-POWR-CIRC

Pressure Switch Contact, NO

CDS014.DWG

E-POWR-CIRC

Pressure Switch Contact, NC

Last Updated: March 2010

Page 130

Engineering Department Manual


E/A Design Division CAD Standard

CDS015.DWG

E-POWR-CIRC

Level Switch Contact, NO

CDS016.DWG

E-POWR-CIRC

Level Switch Contact, NC

CDS017.DWG

E-POWR-CIRC

Flow Switch Contact, NO

CDS018.DWG

E-POWR-CIRC

Flow Switch Contact, NC

CDS019.DWG

E-POWR-CIRC

Temperature Switch, NO

CDS020.DWG

E-POWR-CIRC

Temperature Switch, NC

CDS021.DWG

E-POWR-CIRC

Solenoid

CDS022.DWG

E-POWR-CIRC

Operating Coil

CDS023.DWG

E-POWR-CIRC

3-Position Selector Switch

CDS024.DWG

E-POWR-CIRC

2-Position Selector Switch

CDS025.DWG

E-POWR-CIRC

Fuse

CDS027.DWG

E-POWR-CIRC

Thermal Overload Relay

CDS028.DWG

E-POWR-CIRC

Transformer

Last Updated: March 2010

Page 131

Engineering Department Manual


E/A Design Division CAD Standard

CDS029.DWG

E-POWR-CIRC

Circuit Breaker

CDS030.DWG

E-POWR-CIRC

Disconnect Switch

CDS031.DWG

E-POWR-CIRC

Diode

CDS032.DWG

E-POWR-CIRC

Pilot Light

CDS033.DWG

E-POWR-CIRC

Terminal Block

SLD001.DWG

E-POWR-CIRC

Pothead-Type Cable Termination Medium Voltage

SLD002.DWG

E-POWR-CIRC

Cable Termination Low Voltage

SLD003.DWG

E-POWR-CIRC

Stress Cone Type Cable Termination Medium Voltage

SLD005.DWG

E-POWR-CIRC

Ground and Test Device

SLD006.DWG

E-POWR-CIRC

Ground Terminal Connection

SLD007.DWG

E-POWR-CIRC

Bus Disconnecting Link

SLD010.DWG

E-POWR-CIRC

Power Transformer

SLD010_1.DWG

E-POWR-CIRC

Power Transformer

Last Updated: March 2010

Page 132

Engineering Department Manual


E/A Design Division CAD Standard

SLD011.DWG

E-POWR-CIRC

Power Transformer Automatic Tap Changer

SLD012.DWG

E-POWR-CIRC

Low Voltage 3-Pole AC Circuit Breaker Medium Voltage Fused Load Interrupter Switch Manually Operated

SLD013.DWG

E-POWR-CIRC

SLD014.DWG

E-POWR-CIRC

Ground Connection

SLD015.DWG

E-POWR-CIRC

Ground Connection

SLD016.DWG

E-POWR-CIRC

Low Voltage, Fused Switch, 3Pole U.O.N.

SLD017.DWG

E-POWR-CIRC

Low Voltage, Non-fused Switch, 3Pole U.O.N.

SLD018.DWG

E-POWR-CIRC

Low Voltage, Molded Cased Circuit Breaker, 3-Pole U.O.N.

SLD019.DWG

E-POWR-CIRC

Fuse

SLD020.DWG

E-POWR-CIRC

Draw Out Device

SLD021.DWG

E-POWR-CIRC

Plug-in Device

SLD022.DWG

E-POWR-CIRC

Lightning Arrestor

SLD023.DWG

E-POWR-CIRC

Circuit Device

Last Updated: March 2010

Page 133

Engineering Department Manual


E/A Design Division CAD Standard

SLD024.DWG

E-POWR-CIRC

Neon Indicating Light

SLD025.DWG

E-POWR-CIRC

Normally-Open Contact

SLD025_1.DWG

E-POWR-CIRC

Normally-Closed Contact

SLD025A.DWG

E-POWR-CIRC

Normally-Closed Contact

SLD026.DWG

E-POWR-CIRC

Current Transformer

SLD027.DWG

E-POWR-CIRC

Zero-Sequence Current Transformer

SLD028.DWG

E-POWR-CIRC

Potential Transformer

SLD029.DWG

E-POWR-CIRC

Control Power Transformer

SLD030.DWG

E-POWR-CIRC

Automatic Transfer Switch, 3-Pole U.O.N.

SLD031.DWG

E-POWR-CIRC

Manual Transfer Switch, 3-Pole U.O.N.

SLD032.DWG

E-POWR-CIRC

Medium Voltage Motor Controller, Reduced Voltage, Non-Reversing

SLD033.DWG

E-POWR-CIRC

Medium Voltage Motor Controller, Reduced Voltage, Non-Reversing Low Voltage Motor Controller, Full Voltage, Non-Reversing (FVNR), 3-Pole

SLD034.DWG

E-POWR-CIRC

Last Updated: March 2010

Page 134

Engineering Department Manual


E/A Design Division CAD Standard

SLD035.DWG

E-POWR-CIRC

Low Voltage Motor Controller, Full Voltage, Reversing (FVR), 3-Pole Low Voltage Motor Controller, Full Voltage, Two Speed, NonReversing (FV-25-NR), 3-Pole

SLD036.DWG

E-POWR-CIRC

SLD037.DWG

E-POWR-CIRC

Induction Motor

SLD038.DWG

E-POWR-CIRC

Power Circuit Breaker

SLD039.DWG

E-POWR-CIRC

Battery

SLD040.DWG

E-POWR-CIRC

Resistor

SLD041.DWG

E-POWR-CIRC

Low Voltage Network Protector

SLD042.DWG

E-POWR-CIRC

Emergency Generator

SLD043.DWG

E-POWR-CIRC

Low Voltage, 3-Pole, ManuallyOperated, AC Circuit Breaker

KI001.DWG

E-POWR-CIRC

Interlock with Key Held

KI002.DWG

E-POWR-CIRC

Interlock with Key Removed

KI003.DWG

E-POWR-CIRC

Multi-Lock Interlock with Keys Removed

KI004.DWG

E-POWR-CIRC

Transfer Interlock

Last Updated: March 2010

Page 135

Engineering Department Manual


E/A Design Division CAD Standard
Shows Key Attached to Device with Insulated Chain or Stainless Steel Cable Detachable Latch or Door Interlocks

KI005.DWG

E-POWR-CIRC

KI006.DWG

E-POWR-CIRC

KI007.DWG !!! KI008.DWG KI009.DWG

E-POWR-CIRC E-POWR-CIRC E-POWR-CIRC

Electrical Key Interlock Electrical Key Interlock Mechanical Key Interlock

6.19.4.8

POWER
Symbol Block Name Pwr001.dwg Layer Name E-POWR-DEVC Description 480/277V, 3P, 4W Panelboard

Pwr001A.dwg

E-POWR-DEVC

480/277V, 3P, 4W Panelboard

Pwr002.dwg

E-POWR-DEVC

Distribution Panelboard or Switchboard

Pwr003.dwg

E-POWR-DEVC

Existing 120/208V, 3P, 4W Panelboard

PWR005.DWG

E-POWR-DEVC

Motor Control Center

PWR006.DWG

E-POWR-DEVC

Fused Disconnect Switch

PWR007.DWG

E-POWR-DEVC

Unfused Disconnect Switch

Pwr008.dwg

E-POWR-DEVC

Combination Motor Starter and Fused Switch

Last Updated: March 2010

Page 136

Engineering Department Manual


E/A Design Division CAD Standard

PWR009.DWG

E-POWR-DEVC

Combination Motor Starter and Circuit Breaker

Pwr010.dwg

E-POWR-DEVC

Motor Starter

PWR011.DWG

E-POWR-DEVC

Motor

PWR012.DWG

E-POWR-DEVC

Motorized Damper

PWR013.DWG

E-POWR-DEVC

Automatic Transfer Switch

PWR014.DWG

E-POWR-DEVC

Contactor

PWR015.DWG

E-POWR-DEVC

Transformer

Pwr016.dwg

E-POWR-DEVC

Existing 480/277V, 3P, 4W Panelboard

Pwr016A.dwg

E-POWR-DEVC

Generic Panel

Pwr017.dwg

E-POWR-DEVC

Existing 120/208V, 3P, 4W Panelboard

PWR018.DWG

E-POWR-DEVC

VAV

CAMERA.dwg

E-POWR-DEVC

Camera

Out001.dwg

E-POWR-DEVC

Wall-Mounted Telephone

Last Updated: March 2010

Page 137

Engineering Department Manual


E/A Design Division CAD Standard

Out002.dwg

E-POWR-DEVC

Wall-Mounted Data Outlet

Out002A.dwg

E-POWR-DEVC

Wall-Mounted Combination Telephone/Data Outlet

Out003.dwg

E-POWR-DEVC

Wall-Mounted TV Outlet

OUT004.DWG

E-POWR-DEVC

Wall-Mounted Single Receptacle 20A, 125V, 3W Grounding Type Wall-Mounted Duplex Convenience Receptacle 15a, 125V, 3W Grounding Type Wall-Mounted Multiplex Receptacle Wall-Mounted Quadruplex Receptacle 15a, 125V, 3W Grounding Type Wall-Mounted Single SpecialPurpose Receptacle

OUT005.DWG

E-POWR-DEVC

OUT005_1.DWG

E-POWR-DEVC

OUT006.DWG

E-POWR-DEVC

OUT007.DWG

E-POWR-DEVC

OUT008.DWG

E-POWR-DEVC

Wall-Mounted Duplex SpecialPurpose Receptacle

OUT009.DWG

E-POWR-DEVC

Wall-Mounted Clock Receptacle

Out010.dwg

E-POWR-DEVC

Floor Telephone Outlet

Out011.dwg

E-POWR-DEVC

Floor Data Outlet

Out011A.dwg

E-POWR-DEVC

Floor Combination Telephone/Data Outlet

Last Updated: March 2010

Page 138

Engineering Department Manual


E/A Design Division CAD Standard

OUT012.DWG

E-POWR-DEVC

Floor Single Receptacle 20A, 125V, 3W Floor Duplex Convenience Receptacle 15A, 125V, 3W Grounding Type Unless Otherwise Noted Floor Duplex Convenience Receptacle 15A, 125V, 3W Grounding Type Unless Otherwise Noted Floor Duplex Convenience Receptacle 15A, 125V, 3W Grounding Type Unless Otherwise Noted Floor Single Special-Purpose Receptacle Two Gang Floor Duplex Receptacle 15A, 125V, 3W Grounding-Type Telephone Outlet Two Gang Floor Duplex Receptacle 15A, 125V, 3W Grounding-Type Telephone Outlet Unless Otherwise Noted Two Gang Floor Duplex Receptacle 15A, 125V, 3W Grounding-Type Telephone Outlet Unless Otherwise Noted Two Gang Floor Duplex Receptacle 15A, 125V, 3W Grounding-Type Telephone Outlet Unless Otherwise Noted Two Gang Floor Duplex Receptacle 15A, 125V, 3W Grounding-Type Telephone Outlet Unless Otherwise Noted Two Gang Floor Duplex Receptacle 15A, 125V, 3W Grounding-Type Telephone Outlet Unless Otherwise Noted Two Gang Floor Duplex Receptacle 15A, 125V, 3W Grounding-Type Telephone Outlet Unless Otherwise Noted Two Gang Floor Duplex Receptacle 15A, 125V, 3W Grounding-Type Telephone Outlet Unless Otherwise Noted

OUT013.DWG

E-POWR-DEVC

Out013A.dwg

E-POWR-DEVC

Out13B.dwg

E-POWR-DEVC

OUT014.DWG

E-POWR-DEVC

OUT015.DWG

E-POWR-DEVC

Out016.dwg

E-POWR-DEVC

Out017.dwg

E-POWR-DEVC

Out018.dwg

E-POWR-DEVC

Out019.dwg

E-POWR-DEVC

Out020.dwg

E-POWR-DEVC

Out021.dwg

E-POWR-DEVC

Out022.dwg

E-POWR-DEVC

Last Updated: March 2010

Page 139

Engineering Department Manual


E/A Design Division CAD Standard
Two Gang Floor Duplex Receptacle 15A, 125V, 3W Grounding-Type Telephone Outlet Unless Otherwise Noted 120V-20A Duplex Receptacle

Out023.dwg

E-POWR-DEVC

OUT041.dwg

E-POWR-DEVC

OUT0051.DWG

E-POWR-DEVC

Ground Fault Receptacle

Out051.dwg

E-POWR-DEVC

Ground Fault Receptacle

OUT0061.DWG

E-POWR-DEVC

Ground Fault Receptacle

Pb-desk.dwg

E-POWR-DEVC

Desk-Mounted Push Button

6.19.4.9

UNDERGROUND
Symbol Block Name Ues100.dwg Layer Name E-GNRL-DETL Description Duct Bank Flag

Ues101_1.dwg

E-GNRL-DETL

Duct Bank Flag 1 Conduit Modify to Suit

Ues101_2.dwg

E-GNRL-DETL

Duct Bank Flag 2 Conduit Modify to Suit

Ues101_4.dwg

E-GNRL-DETL

Duct Bank Flag 4 Conduit Modify to Suit

Ues101_6.dwg

E-GNRL-DETL

Duct Bank Flag 6 Conduit Modify to Suit

Ues013.dwg

E-UGND-EXST

Power Manhole

Last Updated: March 2010

Page 140

Engineering Department Manual


E/A Design Division CAD Standard

Ues014.dwg

E-UGND-EXST

Existing Power Manhole

Ues015.dwg

E-UGND-COMM

Communication Manhole

Ues016.dwg

E-UGND-EXST

Existing Communication Manhole

Ues017.dwg

E-UGND-POWR

Power Manhole

Ues018.dwg

E-UGND-EXST

Existing Power Handhole

Ues019.dwg

E-UGND-COMM

Communication Handhole

6.19.4.10

WIRING
Symbol Block Name CC0010.DWG Layer Name E-POWR-CIRC Description Conduit Turn Up

CC0011.DWG

E-POWR-CIRC

Conduit Turn Down

CC00202.DWG

E-POWR-CIRC

2 #12

CC00203.DWG

E-POWR-CIRC

3 #12

CC00204.DWG

E-POWR-CIRC

4 #12

CC00205.DWG

E-POWR-CIRC

5 #12

Last Updated: March 2010

Page 141

Engineering Department Manual


E/A Design Division CAD Standard

CC00206L.DWG

E-POWR-CIRC

Single Home Run

CC00206R.DWG

E-POWR-CIRC

Single Home Run

CC00207L.DWG

E-POWR-CIRC

Two Circuit Home Run

CC00207R.DWG

E-POWR-CIRC

Two Circuit Home Run

CC00208L.DWG

E-POWR-CIRC

Three Circuit Home Run

CC00208R.DWG

E-POWR-CIRC

Three Circuit Home Run

Last Updated: March 2010

Page 142

Engineering Department Manual


E/A Design Division CAD Standard

6.20

APPENDIX D ENVIRONMENTAL DISCIPLINE

6.20.1 CONTENT PREFERENCES This Section Is Under Construction

Last Updated: March 2010

Page 143

Engineering Department Manual


E/A Design Division CAD Standard 6.20.2 LAYER STRATAGEM 6.20.2.1
Discipline

NEW WORK
Description Identification Of Updated Work Witness/Ext. Lines Dim. Arrowheads/Dots/Slashes, Dim. Text Keynotes With Associated Leaderlines And Arrowheads Key Plan Match Line General Notes And General Remarks Non-Plotting Graphics Misc. Symbols Misc.Text And Callouts With Assoc. Leaderlines And Arrowheads Border And Title Block Line Work View Port Acm Type #1 Acm Type #2 Acm Type #3 Acm Type #4 Acm Type #5 Acm Type #6 Airlock Isolation Barrier Construction Aids (Ladders, Scaffolding, Ec.) Containment Limits Critical Barrier Decontamination Unit Dimensions Equipment, (Nuas, Lights, F. Ext.) Flex Tube Exhaust Text Work Area Platform Symbols Work Area Limits Wire Waste Route Acm Type #1 Linetype

Phase

Minor

Major

Color

Annotation N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N Detail N DETL ACM1 8 Continuous Yes ANNO ANNO ANNO ANNO ANNO ANNO ANNO ANNO ANNO ANNO ANNO ASB ASB ASB ASB ASB ASB ASB ASB ASB ASB ASB ASB ASB ASB ASB ASB ASB ASB ASB ASB ASB CHNG DIMS KEYN KEYP MLIN NOTE NPLT SYMB TEXT TTLB VPRT ACM1 ACM2 ACM3 ACM4 ACM5 ACM6 AIRL BARR CNAD CONT CRIT DECN DIMS EQPM FLTB IDEN PLAT SYMB WARA WIRE WSRT 1 1 212 254 4 212 7 3 212 51 200 254 253 252 251 250 7 4 212 8 3 212 212 1 1 5 212 1 3 51 51 51 Continuous Continuous Continuous Continuous Matchline Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous DashDot2 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Border2 Continuous Continuous Yes Yes Yes Yes Yes Yes No Yes Yes Yes No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

Asbestos

Last Updated: March 2010

Plots

Desc

Page 144

Engineering Department Manual


E/A Design Division CAD Standard
N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N Lead N N N N N N N N N N LEAD LEAD LEAD LEAD LEAD LEAD LEAD LEAD LEAD LEAD BARR CNAD CONT DECN DIMS FABT IDEN PLAT SABT WARA ERCT IDEN 212 8 3 212 1 8 212 1 7 51 5 7 Continuous Continuous DashDot2 Continuous Continuous Continuous Continuous Continuous Continuous Border2 Continuous Continuous Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Isolation Barrier Construction Aids (Ladders, Scaffolding, Ec.) Containment Limits Decontamination Unit Dimensions Lcm Full Abatement Text Work Area Platform Lcm Spot Abatement Work Area Limits Erosion Control Text DETL DETL DETL DETL DETL DETL DETL DETL DETL DETL DETL DETL DETL DETL DETL DETL DETL DETL DETL DETL GENE GENE GENE GENE GENE GENE GENE GENE GENE GENE ACM2 ACM3 BARR CNAD CONT DECN DIMS EQPM FILL FLTB IDEN MEMB PIPE PLAT PUMP STRC TANK VLVE WARA WIRE BORE EXWL GEOP GWAT HORW IDEN MONW PLUM REWL TRCH 8 8 212 8 3 212 1 1 1 5 212 4 1 1 212 4 3 1 51 51 4 212 3 7 212 1 3 254 212 3 Continuous Continuous Continuous Continuous DashDot2 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Border2 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Acm Type #2 Acm Type #3 Isolation Barrier Construction Aids (Ladders, Scaffolding, Ec.) Containment Limits Decontamination Unit Dimensions Equipment, (Nuas, Lights, F. Ext.) Fill/Cover Material Flex Tube Exhaust Text Membrane/Netting Pipe And Conduit Work Area Platform Pumps Structural Features Tanks Valves And Fittings Work Area Limits Wiring Soil Bore Sampling Location Extraction Well Location Geo-Probe Location Ground Water Gradient Horizontal Well Location Text Monitoring Well Location Plume Contamination Location Recovery Well Location Trench Location

General Environmental

Permit N N PERM PERM

Last Updated: March 2010

Page 145

Engineering Department Manual


E/A Design Division CAD Standard
N N N N N PERM PERM PERM PERM PERM LMLN REUS SILT ENTR CB__ WETL BUBL SYMB ACM1 ACM2 ACM3 BARR CNAD CONT DECN DIMS EQPM FLTB IDEN MBND MCUT PATT PLAT WARA RAST 3 5 5 1 212 1 3 3 8 8 8 212 8 3 212 1 1 5 212 8 1 8 1 51 254 254 Phantom2 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous DashDot2 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Border2 Continuous Continuous Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Limit Line Addition To Permit Application Scope Silt Fence Construction Entrance Catch Basin Protection Wetland Area Revisions Bubble Revisions Text Acm Type #1 Acm Type #2 Acm Type #3 Isolation Barrier Construction Aids (Ladders, Scaffolding, Ec.) Containment Limits Decontamination Unit Dimensions Equipment, (Nuas, Lights, F. Ext.) Flex Tube Exhaust Text Material Beyond Section Cut Material Cut By Section Textures Work Area Platform Work Area Limits External Reference Drawings Raster Images

N PERM Revisions N REVS

N REVS Sections N N N N N N N N N N N N N N N N N N SECT SECT SECT SECT SECT SECT SECT SECT SECT SECT SECT SECT SECT SECT SECT SECT XREF XREF

6.20.2.2
Discipline Minor Major

EXISTING WORK
Description Existing Witness/Ext. Lines Dim. Arrowheads/Dots/Slashes, Dim. Text Existing Keynotes With Associated Leaderlines And Arrowheads Existing General Notes And General Remarks Existing Misc. Symbols Existing Misc.Text And Callouts With Assoc. Leaderlines And Arrowheads Existing Dimensions Linetype Phase Color Plots Yes Yes Yes Yes Yes Yes Desc ____ ____ ____ ____ ____ ____

Default Existing Layer Properties (Unless Otherwise Noted Below) 253 N ____ ____ ____ EXST Dashed Yes Annotation N N N N N ANNO ANNO ANNO ANNO ANNO DIMS KEYN NOTE SYMB TEXT DIMS EXST EXST EXST EXST EXST EXST 253 253 253 253 253 253 Continuous Continuous Continuous Continuous Continuous Continuous

Asbestos N ASB

Last Updated: March 2010

Page 146

Engineering Department Manual


E/A Design Division CAD Standard
N ASB IDEN N ASB SYMB Detail N DETL DIMS N DETL IDEN General Environmental N GENE IDEN Lead N LEAD DIMS N LEAD IDEN Sections N N SECT SECT DIMS IDEN ____ ____ ____ ____ ____ ____ ____ ____ ____ EXST EXST EXST EXST EXST EXST EXST EXST EXST 253 253 253 253 253 253 253 253 253 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Yes Yes Yes Yes Yes Yes Yes Yes Yes Existing Text Existing Symbols Existing Dimensions Existing Text Existing Text Existing Dimensions Existing Text Existing Dimensions Existing Text

6.20.2.3
Discipline Minor Major

FUTURE WORK
Description Future Witness/Ext. Lines Dim. Arrowheads/Dots/Slashes, Dim. Text Future Keynotes With Associated Leaderlines And Arrowheads Future General Notes And General Remarks Future Misc. Symbols Future Misc.Text And Callouts With Assoc. Leaderlines And Arrowheads Future Dimensions Future Text Future Symbols Future Dimensions Future Text Future Text Future Dimensions Future Text Future Dimensions Future Text Linetype Phase Color Plots Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Desc ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____

Default Future Layer Properties (Unless Otherwise Noted Below) 253 N ____ ____ ____ FUTR Dashed Yes Annotation N N N N N ANNO ANNO ANNO ANNO ANNO DIMS KEYN NOTE SYMB TEXT FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR 253 253 253 253 253 253 253 253 253 253 253 253 253 253 253 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous

Asbestos N ASB DIMS N ASB IDEN N ASB SYMB Detail N DETL DIMS N DETL IDEN General Environmental N GENE IDEN Lead N LEAD DIMS N LEAD IDEN Sections N N SECT SECT DIMS IDEN

Last Updated: March 2010

Page 147

Engineering Department Manual


E/A Design Division CAD Standard 6.20.2.4
Discipline Minor Major

RELOCATED WORK
Description Relocate Witness/Ext. Lines Dim. Arrowheads/Dots/Slashes, Dim. Text Relocate Keynotes With Associated Leaderlines And Arrowheads Relocate General Notes And General Remarks Relocate Misc. Symbols Relocate Misc.Text And Callouts With Assoc. Leaderlines And Arrowheads Relocate Dimensions Relocate Text Relocate Symbols Relocate Dimensions Relocate Text Relocate Text Relocate Dimensions Relocate Text Relocate Dimensions Relocate Text Removal Witness/Ext. Lines Dim. Arrowheads/Dots/Slashes, Dim. Text Removal Keynotes With Associated Leaderlines And Arrowheads Removal General Notes And General Remarks Removal Misc. Symbols Removal Misc.Text And Callouts With Assoc. Leaderlines And Arrowheads Removal Dimensions Removal Text Description Linetype Phase Color Plots Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Plots Desc ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____

Default Relocate Layer Properties (Unless Otherwise Noted Below) 212 N ____ ____ ____ RELO Dashed Yes Annotation N N N N N ANNO ANNO ANNO ANNO ANNO DIMS KEYN NOTE SYMB TEXT RELO RELO RELO RELO RELO 212 212 212 212 212 212 212 212 212 212 212 212 212 212 212 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous

Asbestos N ASB DIMS N ASB IDEN N ASB SYMB Detail N DETL DIMS N DETL IDEN General Environmental N GENE IDEN Lead N LEAD DIMS N LEAD IDEN Sections N N SECT SECT DIMS IDEN

RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO

6.20.2.5
Discipline Minor Major

REMOVAL WORK
Linetype Continuous Continuous Continuous Continuous Continuous Continuous Continuous Phase Color 212 212 212 212 212 212 212 Desc ____ ____ ____ ____ ____ ____ ____

Default Removal Layer Properties (Unless Otherwise Noted Below) 212 N ____ ____ ____ RMVL Dashed Yes Annotation N N N N N ANNO ANNO ANNO ANNO ANNO DIMS KEYN NOTE SYMB TEXT DIMS IDEN RMVL RMVL RMVL RMVL RMVL RMVL RMVL

Asbestos N ASB N ASB

Last Updated: March 2010

Page 148

Engineering Department Manual


E/A Design Division CAD Standard
N ASB SYMB Detail N DETL DIMS N DETL IDEN General Environmental N GENE IDEN Lead N LEAD DIMS N LEAD IDEN Sections N N SECT SECT DIMS IDEN ____ ____ ____ ____ ____ ____ ____ ____ RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL 212 212 212 212 212 212 212 212 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Yes Yes Yes Yes Yes Yes Yes Yes Removal Symbols Removal Dimensions Removal Text Removal Text Removal Dimensions Removal Text Removal Dimensions Removal Text

6.20.2.6
Discipline Minor Major

TEMPORARY WORK
Description Temporary Witness/Ext. Lines Dim. Arrowheads/Dots/Slashes, Dim. Text Temporary Keynotes With Associated Leaderlines And Arrowheads Temporary General Notes And General Remarks Temporary Misc. Symbols Temporary Misc.Text And Callouts With Assoc. Leaderlines And Arrowheads Temporary Dimensions Temporary Text Temporary Symbols Temporary Dimensions Temporary Text Temporary Text Temporary Dimensions Temporary Text Temporary Dimensions Temporary Text Linetype Phase Color Plots Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Desc ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____

Default Temporary Layer Properties (Unless Otherwise Noted Below) TEMP 212 N ____ ____ ____ Dashed Yes Annotation N N N N N ANNO ANNO ANNO ANNO ANNO DIMS KEYN NOTE SYMB TEXT TEMP TEMP TEMP TEMP TEMP TEMP TEMP TEMP TEMP TEMP TEMP TEMP TEMP TEMP TEMP 212 212 212 212 212 212 212 212 212 212 212 212 212 212 212 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous

Asbestos N ASB DIMS N ASB IDEN N ASB SYMB Detail N DETL DIMS N DETL IDEN General Environmental N GENE IDEN Lead N LEAD DIMS N LEAD IDEN Sections N N SECT SECT DIMS IDEN

Last Updated: March 2010

Page 149

Engineering Department Manual


E/A Design Division CAD Standard

6.20.3 LINETYPES Name


Continuous Description Continuous Example

DASHED

Dashed (1x)

DIVIDE

Divide (1x)

Last Updated: March 2010

Page 150

Engineering Department Manual


E/A Design Division CAD Standard

6.20.4 SYMBOLS 6.20.4.1 DRAFTING CONVENTIONS


Symbol Block Name env-CALLOUT.dwg Layer Name (Varies) Description Callout Symbol

env-DET-SYMB.dwg

(Varies)

Detail Symbol

env-SEC-MARK.dwg

(Varies)

Section Mark Symbol

NTS.dwg

(Varies)

Not-to-Scale

6.20.4.2

MISCELLANEOUS
Symbol Block Name ACM.dwg Layer Name (Varies) Description Asbestos-Containing Material

ContainmentLimits.dwg

(Varies)

Containment Limits

CRITICALBARRIER.dwg

(Varies)

Critical Barrier

EEXIT.dwg

(Varies)

Emergency Exit

ELECTRICSOURCE.dwg

(Varies)

Electrical Power Source

EMERGENCYLITE.dwg

(Varies)

Emergency Light

Last Updated: March 2010

Page 151

Engineering Department Manual


E/A Design Division CAD Standard

EXISTINGROOFPOINT.dwg

(Varies)

Existing Roof Footprint

ISOLATIONBARRIER.dwg

(Varies)

Isolation Barrier

NAU.dwg

(Varies)

Negative Air Unit

NAUEXHAUSTROUTE.dwg

(Varies)

NAU Flex Exhaust Route

VIF.dwg

(Varies)

Verify in Field

WATER&DRAIN.dwg

(Varies)

Water/Drain Source Locations

WorkArea1way.dwg

(Varies)

Work Area (One Way) Access/Egress

WorkArea2Way.dwg

(Varies)

Work Area (Two Way) Access/Egress

WorkAreaLimits.dwg

(Varies)

Work Area Limits

Last Updated: March 2010

Page 152

Engineering Department Manual


E/A Design Division CAD Standard

6.21

APPENDIX E GEOTECHNICAL DISCIPLINE

6.21.1 CONTENT PREFERENCES This Section Is Under Construction

Last Updated: March 2010

Page 153

Engineering Department Manual


E/A Design Division CAD Standard 6.21.2 LAYER STRATAGEM 6.21.2.1 NEW WORK

Discipline

Linetype

Phase

Minor

Major

Color

Plots

Desc

Description

ANNOTATION G ANNO CHNG G G G G G G ANNO ANNO ANNO ANNO ANNO ANNO DIMS KEYN MLIN NOTE NPLT SYMB TEXT TTLB TABL VPRT LINE LINE LINE BORE CONC ERTH FILL FLDN GNWD GNRL TEXT LABI PAVE SPCF STEL STRM SUBS INST SURF BORE GNRL GRID MONW SUBS

2 2 2 6 2 6 2 2 210 210 5 140 143 141 3 8 3 3 3 3 3 3 3 3 4 3 3 3 3 3 1 3 132 1 3

Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous

Yes Yes Yes Yes Yes No Yes Yes Yes Yes No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

G ANNO G ANNO G ANNO G ANNO DETAILS G DETL G DETL G DETL G DETL G DETL G DETL G DETL G DETL G DETL G DETL G DETL G DETL G DETL G DETL G DETL G DETL G DETL G DETL G DETL SITE G SITE G SITE G SITE G SITE G SITE

Identification of Updated Work Witness/Extension Lines, Dimension Lines, Arrowheads and Dimension Text Keynotes with Associated Leaderlines and Arrowheads Match Lines General Notes and Remarks Construction Lines/Reference Targets and Review Comments Miscellaneous Symbols Miscellaneous Text with Associated Leaderlines and Arrowheads Border and Title Block Linework Table and Schedule Linework Viewports Medium Weight Detail Linework Light Detail Linework Bold Detail Linework Borings/Perk Holes Concrete Earth/Soil Fill/Cover Material Field Information Ground Water General Features Text Laboratory Information Pavement Special Features Steel Storm Water Subsurface Areas Instrumentation Details Surface Areas Soil Boring Sample Locations General Grid Lines Monitoring Well Locations Subsurface

FINE HEVY

Last Updated: March 2010

Page 154

Engineering Department Manual


E/A Design Division CAD Standard
G SITE G SITE XREF G XREF G XREF SURF TEXT 8 3 210 210 Continuous Continuous Continuous Continuous Yes Yes Yes Yes Surface Text Externally Referenced Drawings Raster Images

RAST

6.21.2.2
Discipline

EXISTING WORK
Linetype Phase

Minor

Major

Color

Plots

Desc

Description

Default Existing Layer Properties (Unless Otherwise Noted Below) G ____ ____ ____ EXST 252 Continuous Yes

6.21.2.3
Discipline

FUTURE WORK
Linetype Phase

Minor

Major

Color

Plots

Desc

Description

Default Future Layer Properties (Unless Otherwise Noted Below) G ____ ____ ____ FUTR 6 Continuous Yes

6.21.2.4

FUTURE WORK

Discipline

Linetype

Phase

Minor

Major

Color

Plots

Desc

Description

Default Future Layer Properties (Unless Otherwise Noted Below) G ____ ____ ____ RELO 6 Continuous Yes

6.21.2.5

REMOVAL WORK

Discipline

Linetype

Phase

Minor

Major

Color

Plots

Desc

Description

Default Removal Layer Properties (Unless Otherwise Noted Below) G ____ ____ ____ RMVL 6 Continuous Yes

Last Updated: March 2010

Page 155

Engineering Department Manual


E/A Design Division CAD Standard 6.21.2.6 TEMPORARY WORK

Discipline

Linetype

Phase

Minor

Major

Color

Plots

Desc

Description

Default Temporary Layer Properties (Unless Otherwise Noted Below) G ____ ____ ____ TEMP 6 Continuous Yes

Last Updated: March 2010

Page 156

Engineering Department Manual


E/A Design Division CAD Standard

6.21.3 LINETYPES Name


Continuous Description Continuous Example

DASHED

Dashed (1x)

DIVIDE

Divide (1x)

Last Updated: March 2010

Page 157

Engineering Department Manual


E/A Design Division CAD Standard

6.21.4 SYMBOLS 6.21.4.1 DRAFTING CONVENTIONS


Symbol Block Name geo-CALLOUT.dwg Layer Name (Varies) Description Callout Symbol

geo-DET-SYMB.dwg

(Varies)

Detail Symbol

geo-SEC-MARK.dwg

(Varies)

Section Mark Symbol

6.21.4.2

MISCELLANEOUS
Symbol Block Name Borehole.dwg Layer Name Description Bore Hole

(Varies)

Caisson.dwg

(Varies)

Caisson

ConePenetometer.dwg

(Varies)

Cone Penetometer Sounding

HML.dwg

(Varies)

HML

H-Piles.dwg

(Varies)

H Piles

MonotubePiles.dwg

(Varies)

Monotube Piles

ObervationWell.dwg

(Varies)

Observation Well

Piezometer.dwg

(Varies)

Piezometer

Last Updated: March 2010

Page 158

Engineering Department Manual


E/A Design Division CAD Standard

PipePiles.dwg

(Varies)

Pipe Piles

PrecastConcretePile.dwg

(Varies)

Precast Concrete

SecantPilesPerm.dwg

(Varies)

Secant Piles

SecantPilesTemp.dwg

(Varies)

Temporary Secant Piles

Seismograph.dwg

(Varies)

Seisomograph

SettlementPlate.dwg

(Varies)

Settlement Plate

SlopeInclinometer.dwg

(Varies)

Slope Inclinometer

SteelSheetPiles.dwg

(Varies)

Steel Sheet Piles

StrainGauge.dwg

(Varies)

Strain Gauge

SurfaceMonitoringPoint.dwg

(Varies)

Surface Monitoring Point

TapeExtensometerSpan.dwg

(Varies)

Tape Extensometer Span

Tapertubepiles.dwg

(Varies)

Taper Tube Piles

Tieback.dwg

(Varies)

Tie Back

Last Updated: March 2010

Page 159

Engineering Department Manual


E/A Design Division CAD Standard

Timberpiles.dwg

(Varies)

Timber Piles

Last Updated: March 2010

Page 160

Engineering Department Manual


E/A Design Division CAD Standard

6.22

APPENDIX F MECHANICAL DISCIPLINE

6.22.1 CONTENT PREFERENCES This Section Is Under Construction

Last Updated: March 2010

Page 161

Engineering Department Manual


E/A Design Division CAD Standard 6.22.2 LAYER STRATAGEM 6.22.2.1
Discipline Minor Major

HVAC NEW WORK


Linetype Phase Color Plots Desc

Description

ANNOTATION M ANNO CHNG M ANNO COLN M ANNO DIMS M ANNO KEYN M ANNO MLIN M ANNO NOTE M ANNO NPLT M ANNO SYMB M ANNO TEXT M ANNO TTLB M ANNO VPRT AVIATION FUEL M AVFL ABVE M AVFL BELW M AVFL EQPT M AVFL OUTS M AVFL TANK M AVFL VALV BACKGROUND M BKGD M BKGD TEXT CONDENSER WATER M CDWR RETN M CDWR RETN M CDWR SUPP M CDWR SUPP CONDENSATE M COND HPIP M COND HPIP M COND TEXT M COND LPIP M COND LPIP M COND MPIP M COND MPIP CHILLED WATER M CHWR RETN M CHWR RETN M CHWR SUPP M CHWR SUPP CONTROLS M CTRL DEVI M CTRL LINK

2 250 8 2 6 2 8 2 2 2 7 6 6 60 6 60 60 253 140 150 150 150 150 140 140 2 140 140 140 140 90 90 90 90 140 170

Continuous Center Continuous Continuous Divide Continuous Continuous Continuous Continuous Continuous Continuous AFS AFSU Continuous AFS Continuous Continuous Continuous Continuous HPC Continuous CHWS Continuous HPC Continuous Continuous LPC Continuous MPC Continuous CWR Continuous CWS Continuous Continuous Dashed

Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

Identification of Updated Work Column Line Dimensions Keynotes Match Lines General Notes and Remarks Construction and Reference Lines Miscellaneous Symbols Annotations Borders View Ports Jet Fuel Above Ground Jet Fuel Below Ground Jet Fuel Equipment Jet Fuel Out Of Service Jet Fuel Tanks Jet Fuel Valves Background Features Background Feature Annotations Condenser Water Piping Return (Schematic) Condenser Water Piping Return Condenser Water Piping Supply (Schematic) Condenser Water Piping Supply High Pressure Condensate Piping (Schematic) High Pressure Condensate Piping High Pressure Condensate Text Low Pressure Condensate Piping (Schematic) Low Pressure Condensate Piping Medium Pressure Condensate Piping (Schematic) Medium Pressure Condensate Piping Chilled Water Piping Return (Schematic) Chilled Water Piping Return Chilled Water Piping Supply (Schematic) Chilled Water Piping Supply Control Devices Control / Communication Link

DBLN DBLN

DBLN

DBLN DBLN

DBLN DBLN

Last Updated: March 2010

Page 162

Engineering Department Manual


E/A Design Division CAD Standard
M CTRL DETAIL M DETL M DETL M DETL M DETL M DETL M DETL M DETL M DETL M DETL DUCT M DUCT M DUCT M DUCT M DUCT M DUCT ELEVATIONS M ELEV M ELEV M ELEV M ELEV M ELEV FUEL M FUEL TEXT CABS DUCT EQPT GENF LVLE PATT PIPE STRC WIRE DAMP DETR EXHT RETN SUPL FIXT IDEN OTLN PATT PFIX FORA 2 7 140 90 243 60 8 6 170 83 140 140 6 231 140 241 9 7 7 2 140 140 140 140 140 140 90 90 90 90 90 231 231 231 231 90 8 2 140 140 90 90 231 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous FOR FORU FOS FOSU FOV FOVU Continuous DTWR Continuous DTWS Continuous HWR Continuous HWS Continuous Continuous Continuous Continuous Continuous Continuous HOSMR Continuous HOSMS Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Control Text Cabinets Ducts Equipment and Fixtures General Features Valves and Fittings Hatch Patterns Piping Structural Support Features Electrical Wiring Fire Damper or Fire / Smoke Damper Smoke or Heat Detector Exhaust Duct Work Return Duct Work Supply Duct Work Miscellaneous Features Component Identification Numbers Building Outlines Textures and Hatch Patterns Plumbing Fixtures Fuel Oil Return Above Fuel Oil Return Below Fuel Oil Suction Above Fuel Oil Suction Below Fuel Oil Tank Vent Above Fuel Oil Tank Vent Below Fuel Oil Tank Dual Temperature Water Piping Return (Schematic) Dual Temperature Water Piping Return Dual Temperature Water Piping Supply (Schematic) Dual Temperature Water Piping Supply Hot Water Piping Return (Schematic) Hot Water Piping Return Hot Water Piping Supply (Schematic) Hot Water Piping Supply HVAC Equipment HVAC Hatch Patterns HVAC Annotations Hot Oil Snow Melting Coil (Schematic) Hot Oil Snow Melting Coil Hot Oil Snow Melting Return Pipe (Schematic) Hot Oil Snow Melting Return Pipe Hot Oil Snow Melting Supply Pipe (Schematic)

M FUEL FORU M FUEL FOSA M FUEL FOSU M FUEL FOVA M FUEL FOVU M FUEL TANK DUAL TEMPERATURE WATER SYSTEM M DTWS M DTWS M DTWS M DTWS HOT WATER M HTWR M HTWR M HTWR M HTWR HVAC RETN RETN SUPP SUPP RETN RETN SUPP SUPP DBLN DBLN

DBLN DBLN

M HVAC EQPM M HVAC PATT M HVAC TEXT HOT OIL - SNOW MELTING SYSTEM M M M M M HTOL HTOL HTOL HTOL HTOL COIL COIL RETN RETN SUPP DBLN DBLN

Last Updated: March 2010

Page 163

Engineering Department Manual


E/A Design Division CAD Standard
M HTOL SUPP DBLN M HTOL VLBX HIGH TEMPERATURE HOT WATER M HTHW RETN M HTHW RETN DBLN M HTHW SUPP M HTHW SUPP DBLN MEDIUM TEMPERATURE HOT WATER M MTHW RETN M MTHW RETN DBLN M MTHW SUPP M MTHW SUPP DBLN MISCELLANEOUS PIPING M MISC BBDN M MISC BKGD M MISC CAIR M MISC DRAN M MISC MWTR PRESENTATION M PRES DBLU M PRES DGRN M PRES DPNK M PRES LBLU M PRES LGRN M PRES LPNK M PRES ORNG M PRES PRPL M PRES RED REFRIGERANT M REFG DISG M REFG LIQD M REFG SCTN RIVER WATER M RIVW M RIVW M RIVW M RIVW SECTIONS M SECT M SECT M SECT M SECT STEAM M M M M M M M STEM STEM STEM STEM STEM STEM XREF BKGD RETN SUPP TUNL TEXT MBND MCUT PATT HPIP HPIP LPIP LPIP MPIP MPIP 231 2 43 43 43 43 231 231 231 231 231 7 140 231 231 180 96 240 120 61 221 41 202 20 231 231 231 6 90 6 6 2 7 7 7 35 35 35 35 35 35 7 Continuous Continuous HTHWR Continuous HTHWS Continuous MTHWR Continuous MTHWS Continuous BBD Continuous A D MU Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous RD RL RS Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous HPS Continuous LPS Continuous MPS Continuous Continuous Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Hot Oil Snow Melting Supply Pipe Hot Oil Snow Melting Valve Box High Temperature Hot Water Return (Schematic) High Temperature Hot Water Return High Temperature Hot Water Supply (Schematic) High Temperature Hot Water Supply Medium Temperature Hot Water Return (Schematic) Medium Temperature Hot Water Return Medium Temperature Hot Water Supply (Schematic) Medium Temperature Hot Water Supply Boiler Blow Down Background Piping Compressed Air Drain Piping Makeup Water Dark Blue Dark Green Dark Pink Light Blue Light Green Light Pink Orange Purple Red Refrigerant Discharge (Schematic) Refrigerant Liquid (Schematic) Refrigerant Suction (Schematic) River Water Background Features River Water Return River Water Supply River Water Tunnel Component Identification Numbers Materials Beyond Section Cut Materials Cut By Section Textures and Hatch Patterns High Pressure Steam Piping (Schematic) High Pressure Steam Piping Low Pressure Steam Piping (Schematic) Low Pressure Steam Piping Medium Pressure Steam Piping (Schematic) Medium Pressure Steam Piping External Reference Drawings

DBLN DBLN DBLN

Last Updated: March 2010

Page 164

Engineering Department Manual


E/A Design Division CAD Standard
M XREF RAST 7 Continuous Yes Raster Images

6.22.2.2
Discipline

HVAC EXISTING WORK


Linetype

Phase

Minor

Major

Color

Plots

Desc

Description

Default Existing Layer Properties (Unless Otherwise Noted Below) M ____ ____ ____ EXST Continuous Yes ANNOTATION M ANNO TEXT ____ EXST 2 Continuous Yes M ANNO COLN ____ EXST 180 Center Yes M ANNO DIMS ____ EXST 8 Continuous Yes M ANNO NOTE ____ EXST 2 Continuous Yes AVIATION FUEL M AVFL ABVE ____ EXST 212 AFS Yes M AVFL BELW ____ EXST 212 AFSU Yes M AVFL EQPT ____ EXST 72 Continuous Yes M AVFL OUTS ____ EXST 212 AFS Yes M AVFL TANK ____ EXST 72 Continuous Yes M AVFL VALV ____ EXST 72 Continuous Yes BACKGROUND M BKGD ____ EXST 253 Continuous Yes M BKGD TEXT ____ EXST 131 Continuous Yes CONDENSER WATER M CDWR RETN ____ EXST 152 HPC Yes M CDWR RETN DBLN EXST 152 Continuous Yes M CDWR SUPP ____ EXST 152 CHWS Yes M CDWR SUPP DBLN EXST 152 Continuous Yes CONDENSATE M COND HPIP ____ EXST 131 HPC Yes M COND HPIP DBLN EXST 131 Continuous Yes M COND TEXT ____ EXST 2 Continuous Yes M COND LPIP ____ EXST 131 LPC Yes M COND LPIP DBLN EXST 131 Continuous Yes M COND MPIP ____ DBLN ____ DBLN ____ DBLN ____ ____ ____ ____ EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST 131 131 92 92 92 92 131 191 2 249 MPC Continuous CWR Continuous CWS Continuous Continuous Dashed Continuous Continuous Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

Existing Annotations Existing Column Line Existing Dimensions Existing General Notes And Remarks Existing Jet Fuel Above Ground Existing Jet Fuel Below Ground Existing Jet Fuel Equipment Existing Jet Fuel Out Of Service Existing Jet Fuel Tanks Existing Jet Fuel Valves Existing Background Features Existing Background Feature Annotations Existing Condenser Water Piping Return (Schematic) Existing Condenser Water Piping Return Existing Condenser Water Piping Supply (Schematic) Existing Condenser Water Piping Supply Existing High Pressure Condensate Piping (Schematic) Existing High Pressure Condensate Piping Existing High Pressure Condensate Text Existing Low Pressure Condensate Piping (Schematic) Existing Low Pressure Condensate Piping Existing Medium Pressure Condensate Piping (Schematic) Existing Medium Pressure Condensate Piping Existing Chilled Water Piping Return (Schematic) Existing Chilled Water Piping Return Existing Chilled Water Piping Supply (Schematic) Existing Chilled Water Piping Supply Existing Control Devices Existing Control / Communication Link Existing Control Text Existing Cabinets

M COND MPIP CHILLED WATER M CHWR RETN M CHWR RETN M CHWR SUPP M CHWR SUPP CONTROLS M CTRL DEVI M CTRL LINK M CTRL TEXT DETAIL M DETL CABS

Last Updated: March 2010

Page 165

Engineering Department Manual


E/A Design Division CAD Standard
M DETL M DETL M DETL M DETL M DETL M DETL M DETL M DETL DUCT M DUCT M DUCT M DUCT M DUCT M DUCT ELEVATIONS M ELEV M ELEV M ELEV M ELEV M ELEV FUEL M FUEL DUCT EQPT GENF LVLE PATT PIPE STRC WIRE DAMP DETR EXHT RETN SUPL FIXT IDEN OTLN PATT PFIX FORA ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST 131 92 234 72 180 212 191 53 131 131 212 10 131 142 46 249 249 53 131 131 131 131 131 131 92 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous FOR FORU FOS FOSU FOV FOVU Continuous Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Existing Ducts Existing Equipment And Fixtures Existing General Features Existing Valves And Fittings Existing Hatch Patterns Existing Piping Existing Structural Support Features Existing Electrical Wiring Existing Fire Damper Or Fire / Smoke Damper Existing Smoke Or Heat Detector Existing Exhaust Duct Work Existing Return Duct Work Existing Supply Duct Work Existing Miscellaneous Features Existing Component Identification Numbers Existing Building Outlines Existing Textures And Hatch Patterns Existing Plumbing Fixtures Existing Fuel Oil Return Above Existing Fuel Oil Return Below Existing Fuel Oil Suction Above Existing Fuel Oil Suction Below Existing Fuel Oil Tank Vent Above Existing Fuel Oil Tank Vent Below Existing Fuel Oil Tank Existing Dual Temperature Water Piping Return (Schematic) Existing Dual Temperature Water Piping Return Existing Dual Temperature Water Piping Supply (Schematic) Existing Dual Temperature Water Piping Supply Existing Hot Water Piping Return (Schematic) Existing Hot Water Piping Return Existing Hot Water Piping Supply (Schematic) Existing Hot Water Piping Supply Existing Hvac Equipment Existing Hvac Hatch Patterns Existing Hvac Annotations Existing Hot Oil Snow Melting Coil (Schematic) Existing Hot Oil Snow Melting Coil Existing Hot Oil Snow Melting Return Pipe (Schematic) Existing Hot Oil Snow Melting Return Pipe Existing Hot Oil Snow Melting Supply Pipe (Schematic) Existing Hot Oil Snow Melting Supply Pipe Existing Hot Oil Snow Melting Valve Box

M FUEL FORU ____ EXST M FUEL FOSA ____ EXST M FUEL FOSU ____ EXST M FUEL FOVA ____ EXST M FUEL FOVU ____ EXST M FUEL TANK ____ EXST DUAL TEMPERATURE WATER SYSTEM M M DTWS DTWS RETN RETN SUPP SUPP RETN RETN SUPP SUPP ____ DBLN ____ DBLN ____ DBLN ____ DBLN EXST EXST EXST EXST EXST EXST EXST EXST

92 92 92 92 10 10 10 10 92 180 2 131 131 92 92 10 10 53

DTWR Continuous DTWS Continuous HWR Continuous HWS Continuous Continuous Continuous Continuous Continuous Continuous HOSMR Continuous HOSMS Continuous Continuous

Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

M DTWS M DTWS HOT WATER M HTWR M HTWR M HTWR M HTWR HVAC

M HVAC EQPM ____ EXST M HVAC PATT ____ EXST M HVAC TEXT ____ EXST HOT OIL - SNOW MELTING SYSTEM M M M M M M M HTOL HTOL HTOL HTOL HTOL HTOL HTOL COIL COIL RETN RETN SUPP SUPP VLBX ____ DBLN ____ DBLN ____ DBLN ____ EXST EXST EXST EXST EXST EXST EXST

Last Updated: March 2010

Page 166

Engineering Department Manual


E/A Design Division CAD Standard
HIGH TEMPERATURE HOT WATER M M HTHW HTHW RETN RETN ____ DBLN EXST EXST 41 41 41 41 HTHWR Continuous HTHWS Continuous Yes Yes Yes Yes Existing High Temperature Hot Water Return (Schematic) Existing High Temperature Hot Water Return Existing High Temperature Hot Water Supply (Schematic) Existing High Temperature Hot Water Supply Existing Medium Temperature Hot Water Return (Schematic) Existing Medium Temperature Hot Water Return Existing Medium Temperature Hot Water Supply (Schematic) Existing Medium Temperature Hot Water Supply Existing Boiler Blow Down Existing Background Piping Existing Compressed Air Existing Drain Piping Existing Makeup Water Existing Red Existing Refrigerant Discharge (Schematic) Existing Refrigerant Liquid (Schematic) Existing Refrigerant Suction (Schematic) Existing River Water Background Features Existing River Water Return Existing River Water Supply Existing River Water Tunnel Existing Component Identification Numbers Existing Materials Beyond Section Cut Existing Materials Cut By Section Existing Textures And Hatch Patterns Existing High Pressure Steam Piping (Schematic) Existing High Pressure Steam Piping Existing Low Pressure Steam Piping (Schematic) Existing Low Pressure Steam Piping Existing Medium Pressure Steam Piping (Schematic) Existing Medium Pressure Steam Piping

M HTHW SUPP ____ EXST M HTHW SUPP DBLN EXST MEDIUM TEMPERATURE HOT WATER M M MTHW MTHW RETN RETN ____ DBLN EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST

10 10 10 10 10 249 131 10 10 1 10 10 10 212 92 212 212 2 249 249 249 15 15 15 15 15 15

MTHWR Continuous MTHWS Continuous BBD Continuous A D MU Continuous RD RL RS Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous HPS Continuous LPS Continuous MPS Continuous

Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

M MTHW SUPP ____ M MTHW SUPP DBLN MISCELLANEOUS PIPING M MISC BBDN M MISC BKGD M MISC CAIR M MISC DRAN M MISC MWTR PRESENTATION M PRES RED REFRIGERANT M REFG DISG M REFG LIQD M REFG SCTN RIVER WATER M RIVW BKGD M RIVW RETN M RIVW SUPP M RIVW TUNL SECTIONS M SECT TEXT M SECT MBND M SECT MCUT M SECT PATT STEAM M STEM HPIP M STEM HPIP M STEM LPIP M STEM LPIP M STEM MPIP M STEM MPIP ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ DBLN ____ DBLN ____ DBLN

6.22.2.3

HVAC FUTURE WORK

Discipline

Linetype

Phase

Minor

Major

Color

Plots

Desc

Description

Last Updated: March 2010

Page 167

Engineering Department Manual


E/A Design Division CAD Standard
Default Future Layer Properties (Unless Otherwise Noted Below) M ____ ____ ____ FUTR Continuous Yes ANNOTATION M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M ANNO ANNO ANNO ANNO AVFL AVFL AVFL AVFL AVFL AVFL BKGD BKGD CDWR CDWR CDWR CDWR COND COND COND COND COND COND COND CHWR CHWR CHWR CHWR CTRL CTRL CTRL DETL DETL DETL DETL DETL TEXT RETN RETN SUPP SUPP HPIP HPIP TEXT LPIP LPIP MPIP MPIP RETN RETN SUPP SUPP DEVI LINK TEXT CABS DUCT EQPT GENF LVLE COLN DIMS NOTE TEXT ABVE BELW EQPT OUTS TANK VALV _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ DBLN _____ DBLN _____ DBLN _____ _____ DBLN _____ DBLN _____ DBLN _____ DBLN _____ _____ _____ _____ _____ _____ _____ _____ FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR 180 8 2 2 212 212 72 212 72 72 253 131 152 152 152 152 131 131 2 131 131 131 131 92 92 92 92 131 191 2 249 131 92 234 72 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Future Column Line Future Dimensions Future General Notes And Remarks Future Annotations Future Jet Fuel Above Ground Future Jet Fuel Below Ground Future Jet Fuel Equipment Future Jet Fuel Out Of Service Future Jet Fuel Tanks Future Jet Fuel Valves Future Background Features Future Background Feature Annotations Future Condenser Water Piping Return (Schematic) Future Condenser Water Piping Return Future Condenser Water Piping Supply (Schematic) Future Condenser Water Piping Supply Future High Pressure Condensate Piping (Schematic) Future High Pressure Condensate Piping Future High Pressure Condensate Text Future Low Pressure Condensate Piping (Schematic) Future Low Pressure Condensate Piping Future Medium Pressure Condensate Piping (Schematic) Future Medium Pressure Condensate Piping Future Chilled Water Piping Return (Schematic) Future Chilled Water Piping Return Future Chilled Water Piping Supply (Schematic) Future Chilled Water Piping Supply Future Control Devices Future Control / Communication Link Future Control Text Future Cabinets Future Ducts Future Equipment And Fixtures Future General Features Future Valves And Fittings

AVIATION FUEL

BACKGROUND

CONDENSER WATER

CONDENSATE

CHILLED WATER

CONTROLS

DETAIL

Last Updated: March 2010

Page 168

Engineering Department Manual


E/A Design Division CAD Standard
M M M M DUCT M M M M M M M M M M FUEL M M M M M M FUEL FUEL FUEL FUEL FUEL FUEL FORA FORU FOSA FOSU FOVA FOVU _____ _____ _____ _____ _____ _____ FUTR FUTR FUTR FUTR FUTR FUTR 131 131 131 131 131 131 92 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Yes Yes Yes Yes Yes Yes Yes Future Fuel Oil Return Above Future Fuel Oil Return Below Future Fuel Oil Suction Above Future Fuel Oil Suction Below Future Fuel Oil Tank Vent Above Future Fuel Oil Tank Vent Below Future Fuel Oil Tank Future Dual Temperature Water Piping Return (Schematic) Future Dual Temperature Water Piping Return Future Dual Temperature Water Piping Supply (Schematic) Future Dual Temperature Water Piping Supply Future Hot Water Piping Return (Schematic) Future Hot Water Piping Return Future Hot Water Piping Supply (Schematic) Future Hot Water Piping Supply Future Hvac Equipment Future Hvac Hatch Patterns Future Hvac Annotations Future Hot Oil Snow Melting Coil (Schematic) Future Hot Oil Snow Melting Coil Future Hot Oil Snow Melting Return Pipe (Schematic) Future Hot Oil Snow Melting Return Pipe Future Hot Oil Snow Melting Supply Pipe (Schematic) DUCT DUCT DUCT DUCT DUCT ELEV ELEV ELEV ELEV ELEV DAMP DETR EXHT RETN SUPL FIXT IDEN OTLN PATT PFIX _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR 131 131 212 10 131 142 46 249 249 53 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Future Fire Damper Or Fire / Smoke Damper Future Smoke Or Heat Detector Future Exhaust Duct Work Future Return Duct Work Future Supply Duct Work Future Miscellaneous Features Future Component Identification Numbers Future Building Outlines Future Textures And Hatch Patterns Future Plumbing Fixtures DETL DETL DETL DETL PATT PIPE STRC WIRE _____ _____ _____ _____ FUTR FUTR FUTR FUTR 180 212 191 53 Hidden2 Hidden2 Hidden2 Hidden2 Yes Yes Yes Yes Future Hatch Patterns Future Piping Future Structural Support Features Future Electrical Wiring

ELEVATIONS

M FUEL TANK _____ FUTR DUAL TEMPERATURE WATER SYSTEM M M M DTWS DTWS DTWS RETN RETN SUPP SUPP RETN RETN SUPP SUPP EQPM PATT _____ DBLN _____ DBLN _____ DBLN _____ DBLN _____ _____ FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR

92 92 92 92 10 10 10 10 92 180 2 131 131 92 92 10

Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2

Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

M DTWS HOT WATER M M M HTWR HTWR HTWR

M HTWR HVAC M M HVAC HVAC

M HVAC TEXT _____ FUTR HOT OIL - SNOW MELTING SYSTEM M M M M M HTOL HTOL HTOL HTOL HTOL COIL COIL RETN RETN SUPP _____ DBLN _____ DBLN _____ FUTR FUTR FUTR FUTR FUTR

Last Updated: March 2010

Page 169

Engineering Department Manual


E/A Design Division CAD Standard
M HTOL SUPP DBLN FUTR 10 53 41 41 41 41 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Yes Yes Yes Yes Yes Yes Future Hot Oil Snow Melting Supply Pipe Future Hot Oil Snow Melting Valve Box Future High Temperature Hot Water Return (Schematic) Future High Temperature Hot Water Return Future High Temperature Hot Water Supply (Schematic) Future High Temperature Hot Water Supply Future Medium Temperature Hot Water Return (Schematic) Future Medium Temperature Hot Water Return Future Medium Temperature Hot Water Supply (Schematic) Future Medium Temperature Hot Water Supply Future Boiler Blow Down Future Background Piping Future Compressed Air Future Drain Piping Future Makeup Water Future Red Future Refrigerant Discharge (Schematic) Future Refrigerant Liquid (Schematic) Future Refrigerant Suction (Schematic) Future River Water Background Features Future River Water Return Future River Water Supply Future River Water Tunnel Future Component Identification Numbers Future Materials Beyond Section Cut Future Materials Cut By Section Future Textures And Hatch Patterns Future High Pressure Steam Piping (Schematic) Future High Pressure Steam Piping Future Low Pressure Steam Piping (Schematic) Future Low Pressure Steam Piping Future Medium Pressure Steam Piping (Schematic) Future Medium Pressure Steam Piping

M HTOL VLBX _____ FUTR HIGH TEMPERATURE HOT WATER M M M HTHW HTHW HTHW RETN RETN SUPP _____ DBLN _____ FUTR FUTR FUTR

M HTHW SUPP DBLN FUTR MEDIUM TEMPERATURE HOT WATER M M M MTHW MTHW MTHW RETN RETN SUPP _____ DBLN _____ FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR

10 10 10 10 10 249 131 10 10 1 10 10 10 212 92 212 212 2 249 249 249 15 15 15 15 15 15

Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Hidden2

Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

M MTHW SUPP DBLN MISCELLANEOUS PIPING M M M M MISC MISC MISC MISC BBDN BKGD CAIR DRAN _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ DBLN _____ DBLN _____ DBLN

M MISC MWTR PRESENTATION M PRES RED REFRIGERANT M M REFG REFG DISG LIQD

M REFG SCTN RIVER WATER M M M RIVW RIVW RIVW BKGD RETN SUPP TUNL TEXT MBND MCUT PATT HPIP HPIP LPIP LPIP MPIP MPIP

M RIVW SECTIONS M M M SECT SECT SECT

M SECT STEAM M M M M M M STEM STEM STEM STEM STEM STEM

Last Updated: March 2010

Page 170

Engineering Department Manual


E/A Design Division CAD Standard 6.22.2.4 HVAC RELOCATED WORK

Discipline

Linetype

Phase

Minor

Major

Color

Plots

Desc

Description

Default Relocated Layer Properties (Unless Otherwise Noted Below) M ____ ____ ____ RELO 20 Continuous Yes GENERAL M M M M M PLAN PLAN DETL ELEV ELEV ____ FINE ____ ____ FINE ____ ____ ____ ____ ____ RELO RELO RELO RELO RELO 20 22 20 20 22 Continuous Continuous Continuous Continuous Continuous Yes Yes Yes Yes Yes Relocated Elements in Plan Relocated Elements in Plan (Thin Line) Relocated Elements in Details Relocated Elements in Elevation or Section Relocated Elements in Plan (Thin Line)

6.22.2.5

HVAC REMOVAL WORK

Discipline

Linetype

Phase

Minor

Major

Color

Plots

Desc

Description

Default Removal Layer Properties (Unless Otherwise Noted Below) M ____ ____ ____ RMVL Continuous Yes X - REMOVALS M PLAN GRFX ____ SHRT _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ TEXT _____ RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL 170 170 250 8 2 2 6 6 60 6 60 60 253 140 MECHANICAL_ REMOVAL MECHANICAL_ REMOVAL_s Center Continuous Continuous Continuous AFS AFSU Continuous AFS Continuous Continuous Continuous Continuous Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Draw Over RMVL Linework Normal Spacing Draw Over RMVL Linework Short Spacing Removal Of Column Line Removal Of Dimensions Removal Of General Notes And Remarks Removal Of Annotations Removal Of Jet Fuel Above Ground Removal Of Jet Fuel Below Ground Removal Of Jet Fuel Equipment Removal Of Jet Fuel Out Of Service Removal Of Jet Fuel Tanks Removal Of Jet Fuel Valves Removal Of Background Features Removal Of Background Feature Annotations

M PLAN GRFX ANNOTATION M M M M ANNO ANNO ANNO ANNO COLN DIMS NOTE TEXT

AVIATION FUEL M AVFL ABVE M M M M M AVFL AVFL AVFL AVFL AVFL BELW EQPT OUTS TANK VALV

BACKGROUND M BKGD M BKGD

Last Updated: March 2010

Page 171

Engineering Department Manual


E/A Design Division CAD Standard
CONDENSER WATER M M M M CDWR CDWR CDWR CDWR RETN RETN SUPP SUPP _____ DBLN _____ DBLN RMVL RMVL RMVL RMVL 150 150 150 150 HPC Continuous CHWS Continuous Yes Yes Yes Yes Removal Of Condenser Water Piping Return (Schematic) Removal Of Condenser Water Piping Return Removal Of Condenser Water Piping Supply (Schematic) Removal Of Condenser Water Piping Supply Removal Of High Pressure Condensate Piping (Schematic) Removal Of High Pressure Condensate Piping Removal Of High Pressure Condensate Text Removal Of Low Pressure Condensate Piping (Schematic) Removal Of Low Pressure Condensate Piping Removal Of Medium Pressure Condensate Piping (Schematic) Removal Of Medium Pressure Condensate Piping Removal Of Chilled Water Piping Return (Schematic) Removal Of Chilled Water Piping Return Removal Of Chilled Water Piping Supply (Schematic) Removal Of Chilled Water Piping Supply Removal Of Control Devices Removal Of Control / Communication Link Removal Of Control Text Removal Of Cabinets Removal Of Ducts Removal Of Equipment And Fixtures Removal Of General Features Removal Of Valves And Fittings Removal Of Hatch Patterns Removal Of Piping Removal Of Structural Support Features Removal Of Electrical Wiring Removal Of Fire Damper Or Fire / Smoke Damper Removal Of Smoke Or Heat Detector Removal Of Exhaust Duct Work Removal Of Return Duct Work Removal Of Supply Duct Work Removal Of Miscellaneous Features Removal Of Component Identification Numbers Removal Of Building Outlines

CONDENSATE M M M M M M M COND COND COND COND COND COND COND HPIP HPIP TEXT LPIP LPIP MPIP MPIP _____ DBLN _____ _____ DBLN _____ DBLN RMVL RMVL RMVL RMVL RMVL RMVL RMVL 140 140 2 140 140 140 140 HPC Continuous Continuous LPC Continuous MPC Continuous Yes Yes Yes Yes Yes Yes Yes

CHILLED WATER M M M M CHWR CHWR CHWR CHWR RETN RETN SUPP SUPP DEVI LINK TEXT CABS DUCT EQPT GENF LVLE PATT PIPE STRC WIRE DAMP DETR EXHT RETN SUPL FIXT IDEN OTLN _____ DBLN _____ DBLN _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL 90 90 90 90 140 170 2 7 140 90 243 60 8 6 170 83 140 140 6 231 140 241 9 7 CWR Continuous CWS Continuous Continuous Dashed Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

CONTROLS M CTRL M M CTRL CTRL

DETAIL M DETL M M M M M M M M DETL DETL DETL DETL DETL DETL DETL DETL

DUCT M DUCT M M M M DUCT DUCT DUCT DUCT

ELEVATIONS M ELEV M M ELEV ELEV

Last Updated: March 2010

Page 172

Engineering Department Manual


E/A Design Division CAD Standard
M M ELEV ELEV PATT PFIX FORA FORU FOSA FOSU FOVA FOVU TANK _____ _____ _____ _____ _____ _____ _____ _____ _____ RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL 7 2 140 140 140 140 140 140 90 Continuous Continuous FOR FORU FOS FOSU FOV FOVU Continuous Yes Yes Yes Yes Yes Yes Yes Yes Yes Removal Of Textures And Hatch Patterns Removal Of Plumbing Fixtures Removal Of Fuel Oil Return Above Removal Of Fuel Oil Return Below Removal Of Fuel Oil Suction Above Removal Of Fuel Oil Suction Below Removal Of Fuel Oil Tank Vent Above Removal Of Fuel Oil Tank Vent Below Removal Of Fuel Oil Tank Removal Of Dual Temperature Water Piping Return (Schematic) Removal Of Dual Temperature Water Piping Return Removal Of Dual Temperature Water Piping Supply (Schematic) Removal Of Dual Temperature Water Piping Supply Removal Of Hot Water Piping Return (Schematic) Removal Of Hot Water Piping Return Removal Of Hot Water Piping Supply (Schematic) Removal Of Hot Water Piping Supply Removal Of Hvac Equipment Removal Of Hvac Hatch Patterns Removal Of Hvac Annotations Removal Of Hot Oil Snow Melting Coil (Schematic) Removal Of Hot Oil Snow Melting Coil Removal Of Hot Oil Snow Melting Return Pipe (Schematic) Removal Of Hot Oil Snow Melting Return Pipe Removal Of Hot Oil Snow Melting Supply Pipe (Schematic) Removal Of Hot Oil Snow Melting Supply Pipe Removal Of Hot Oil Snow Melting Valve Box Removal Of High Temperature Hot Water Return (Schematic) Removal Of High Temperature Hot Water Return Removal Of High Temperature Hot Water Supply (Schematic) Removal Of High Temperature Hot Water Supply Removal Of Medium Temperature Hot Water Return (Schematic) Removal Of Medium Temperature Hot Water Return Removal Of Medium Temperature Hot Water Supply (Schematic) Removal Of Medium Temperature Hot Water Supply

FUEL M FUEL M M M M M M FUEL FUEL FUEL FUEL FUEL FUEL

DUAL TEMPERATURE WATER SYSTEM M M M M M M M M M M M M M M M M M M DTWS DTWS DTWS DTWS HTWR HTWR HTWR HTWR HVAC HVAC HVAC HTOL HTOL HTOL HTOL HTOL HTOL HTOL RETN RETN SUPP SUPP RETN RETN SUPP SUPP EQPM PATT TEXT COIL COIL RETN RETN SUPP SUPP VLBX _____ DBLN _____ DBLN _____ DBLN _____ DBLN _____ _____ _____ _____ DBLN _____ DBLN _____ DBLN _____ RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL 90 90 90 90 231 231 231 231 90 8 2 140 140 90 90 231 231 2 DTWR Continuous DTWS Continuous HWR Continuous HWS Continuous Continuous Continuous Continuous Continuous Continuous HOSMR Continuous HOSMS Continuous Continuous Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

HOT WATER

HVAC

HOT OIL - SNOW MELTING SYSTEM

HIGH TEMPERATURE HOT WATER M M M M HTHW HTHW HTHW HTHW RETN RETN SUPP SUPP _____ DBLN _____ DBLN RMVL RMVL RMVL RMVL 43 43 43 43 HTHWR Continuous HTHWS Continuous Yes Yes Yes Yes

MEDIUM TEMPERATURE HOT WATER M M M M MTHW MTHW MTHW MTHW RETN RETN SUPP SUPP _____ DBLN _____ DBLN RMVL RMVL RMVL RMVL 231 231 231 231 MTHWR Continuous MTHWS Continuous Yes Yes Yes Yes

Last Updated: March 2010

Page 173

Engineering Department Manual


E/A Design Division CAD Standard
MISCELLANEOUS PIPING M M M M M M M M M M M M M M M M M MISC MISC MISC MISC MISC PRES REFG REFG REFG RIVW RIVW RIVW RIVW SECT SECT SECT SECT BBDN BKGD CAIR DRAN MWTR RED DISG LIQD SCTN BKGD RETN SUPP TUNL TEXT MBND MCUT PATT _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ _____ RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL 231 7 140 231 231 20 231 231 231 6 90 6 6 2 7 7 7 BBD Continuous A D MU Continuous RD RL RS Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Removal Of Boiler Blow Down Removal Of Background Piping Removal Of Compressed Air Removal Of Drain Piping Removal Of Makeup Water Removal Of Red Removal Of Refrigerant Discharge (Schematic) Removal Of Refrigerant Liquid (Schematic) Removal Of Refrigerant Suction (Schematic) Removal Of River Water Background Features Removal Of River Water Return Removal Of River Water Supply Removal Of River Water Tunnel Removal Of Component Identification Numbers Removal Of Materials Beyond Section Cut Removal Of Materials Cut By Section Removal Of Textures And Hatch Patterns Removal Of High Pressure Steam Piping (Schematic) Removal Of High Pressure Steam Piping Removal Of Low Pressure Steam Piping (Schematic) Removal Of Low Pressure Steam Piping Removal Of Medium Pressure Steam Piping (Schematic) Removal Of Medium Pressure Steam Piping

PRESENTATION REFRIGERANT

RIVER WATER

SECTIONS

STEAM M M M M M M STEM STEM STEM STEM STEM STEM HPIP HPIP LPIP LPIP MPIP MPIP _____ DBLN _____ DBLN _____ DBLN RMVL RMVL RMVL RMVL RMVL RMVL 35 35 35 35 35 35 HPS Continuous LPS Continuous MPS Continuous Yes Yes Yes Yes Yes Yes

6.22.2.6
Discipline

HVAC TEMPORARY WORK


Linetype

Phase

Minor

Major

Color

Plots

Desc

Description

Default Temporary Layer Properties (Unless Otherwise Noted Below) M TEMP ____ ____ ____ 20 Continuous Yes GENERAL M M M M M PLAN PLAN DETL ELEV ELEV ____ FINE ____ ____ FINE ____ ____ ____ ____ ____ TEMP TEMP TEMP TEMP TEMP 234 244 234 234 244 Continuous Continuous Continuous Continuous Continuous Yes Yes Yes Yes Yes Temporary Elements in Plan Temporary Elements in Plan (Thin Line) Temporary Elements in Details Temporary Elements in Elevation or Sections Temporary Elements in Plan (Thin Line)

Last Updated: March 2010

Page 174

Engineering Department Manual


E/A Design Division CAD Standard
M ELEV FINE ____ TEMP 244 Continuous Yes Temporary Elements in Plan (Thin Line)

6.22.2.7

FIRE PROTECTION NEW WORK

Discipline

Linetype

Phase

Minor

Major

Color

Plots

Desc

Description

ANNOTATION F F F F F F F F F F F F F F F F F F F F F F F F F F CO2 F F F F FM200 CO2_ CO2_ CO2_ CO2_ EQPM HEAD PIPE 231 231 231 131 Continuous Continuous Continuous CO2 Yes Yes Yes Yes CO2 System CO2 Equipment CO2 Head CO2 Sprinkler Piping ANNO ANNO ANNO ANNO ANNO ANNO ANNO ANNO ANNO ANNO DETL DETL DETL DETL DETL DETL DETL DETL DETL DETL DETL ELEV ELEV ELEV ELEV ELEV CHNG DIMS KEYN MLIN NOTE NPLT SYMB TEXT TTLB VPRT CABS DUCT EQPT FANS GENF GRLS LVLE PUMP STRC VENT WIRE FIXT IDEN OTLN PATT PFIX 2 8 2 6 2 8 2 2 2 7 7 140 90 90 243 140 60 60 170 35 83 241 9 7 7 2 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Dashed Continuous Continuous Continuous Continuous Continuous Continuous Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Identification of Updated Work Dimensions Keynotes Match Lines General Notes and Remarks Construction and Reference Lines Miscellaneous Symbols Miscellaneous Annotations Borders View Ports Hose Cabinets Ducts Equipment and Fixtures Fans General Features Grilles and Louvers Valves and Fittings Pumps and Compressors Structural Support Features Vents Electrical Wiring Miscellaneous Fixtures Component Identification Numbers Building Outlines Textures and Patterns Plumbing Fixtures

DETAIL

ELEVATIONS

Last Updated: March 2010

Page 175

Engineering Department Manual


E/A Design Division CAD Standard
F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F FM2_ FM2_ FM2_ FM2_ INGN INGN INGN INGN SECT SECT SECT SECT WET_ WET_ WET_ WET_ WET_ WET_ WET_ WET_ DELU DELU DELU DELU DELU DELU DELU DELU DRYC DRYC DRYC DRYC DRYC DRYC DRYC DRYC DRY_ DRY_ DRY_ DRY_ DRY_ DRY_ EQPM HEAD PIPE IDEN MBND MCUT PATT EQUP HEAD HEAD HEAD HEAD HEAD HEAD PIPE EQUP HEAD HEAD HEAD HEAD HEAD HEAD PIPE EQUP HEAD HEAD HEAD HEAD HEAD HEAD PIPE EQUP HEAD HEAD HEAD HEAD HEAD PNDT CONC RECD SIDE PNDT CONC RECD SIDE UPRT PNDT CONC RECD SIDE UPRT PNDT CONC RECD SIDE UPRT EQPM HEAD PIPE 231 231 231 131 231 231 231 131 2 7 7 7 231 131 131 131 131 131 131 131 231 131 131 131 131 131 131 131 231 131 131 131 131 131 131 131 231 131 131 131 131 131 Continuous Continuous Continuous FM_200 Continuous Continuous Continuous INERGEN Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous SP Continuous Continuous Continuous Continuous Continuous Continuous Continuous DEL Continuous Continuous Continuous Continuous Continuous Continuous Continuous DRY_CHEM Continuous Continuous Continuous Continuous Continuous Continuous Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes FM 200 System FM 200 Equipment FM 200 Head FM 200 Sprinkler Piping Inergen System Inergen Equipment Inergen Head Inergen Piping Component Identification Numbers Materials Beyond Section Cut Materials Cut By Section Textures and Patterns Wet Sprinkler Equipment Wet Sprinkler Heads Wet Sprinkler Pendant Heads Wet Sprinkler Concealed Heads Wet Sprinkler Recessed Heads Wet Sprinkler Sidewall Heads Wet Sprinkler Upright Heads Wet Sprinkler Piping Deluge Sprinkler Equipment Deluge Sprinkler Heads Deluge Sprinkler Pendant Heads Deluge Sprinkler Concealed Heads Deluge Sprinkler Recessed Heads Deluge Sprinkler Sidewall Heads Deluge Sprinkler Upright Heads Deluge Sprinkler Piping Dry Chemical Sprinkler Equipment Dry Chemical Sprinkler Heads Dry Chemical Sprinkler Pendant Heads Dry Chemical Sprinkler Concealed Heads Dry Chemical Sprinkler Recessed Heads Dry Chemical Sprinkler Sidewall Heads Dry Chemical Sprinkler Upright Heads Dry Chemical Sprinkler Piping Dry Sprinkler Equipment Dry Sprinkler Heads Dry Sprinkler Pendant Heads Dry Sprinkler Concealed Heads Dry Sprinkler Recessed Heads Dry Sprinkler Sidewall Heads

INERGEN

SECTIONS

SPRINKLER

Last Updated: March 2010

Page 176

Engineering Department Manual


E/A Design Division CAD Standard
F F F F F F F F F F F F F F F F F F F XREF F F XREF XREF RAST 7 7 Continuous Continuous Yes Yes Externally Referenced Drawings Raster Images DRY_ DRY_ FOAM FOAM FOAM FOAM FOAM FOAM FOAM FOAM PREA PREA PREA PREA PREA PREA PREA PREA SPKL HEAD PIPE EQUP HEAD HEAD HEAD HEAD HEAD HEAD PIPE EQUP HEAD HEAD HEAD HEAD HEAD HEAD PIPE TEXT PNDT CONC RECD SIDE UPRT PNDT CONC RECD SIDE UPRT UPRT 131 131 231 131 131 131 131 131 131 131 231 131 131 131 131 131 131 131 2 Continuous DRY Continuous Continuous Continuous Continuous Continuous Continuous Continuous FOAM Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Dry Sprinkler Upright Heads Dry Sprinkler Piping Foam Sprinkler Equipment Foam Sprinkler Heads Foam Sprinkler Pendant Heads Foam Sprinkler Concealed Heads Foam Sprinkler Recessed Heads Foam Sprinkler Sidewall Heads Foam Sprinkler Upright Heads Foam Sprinkler Piping Pre-Action Sprinkler Equipment Pre-Action Sprinkler Heads Pre-Action Sprinkler Pendant Heads Pre-Action Sprinkler Concealed Heads Pre-Action Sprinkler Recessed Heads Pre-Action Sprinkler Sidewall Heads Pre-Action Sprinkler Upright Heads Pre-Action Sprinkler Piping Fire Protection Annotations

6.22.2.8

FIRE PROTECTION EXISTING WORK

Discipline

Linetype

Phase

Minor

Major

Color

Plots

Desc

Description

Default Existing Layer Properties (Unless Otherwise Noted Below) F F F F F F F F F F F ____ ANNO ANNO ANNO DETL DETL DETL DETL DETL DETL DETL ____ DIMS NOTE TEXT CABS DUCT EQPT FANS GENF GRLS LVLE ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST 8 2 2 249 131 92 92 234 131 72 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Existing Dimensions Existing General Notes And Remarks Existing Miscellaneous Annotations Existing Hose Cabinets Existing Ducts Existing Equipment And Fixtures Existing Fans Existing General Features Existing Grilles And Louvers Existing Valves And Fittings ANNOTATION

DETAIL

Last Updated: March 2010

Page 177

Engineering Department Manual


E/A Design Division CAD Standard
F F F F F F F F F CO2 F F F F FM200 F F F F F F F F F F F F F F F F F F F F F F F F F F FM2_ FM2_ FM2_ FM2_ INGN INGN INGN INGN SECT SECT SECT WET_ WET_ WET_ WET_ WET_ WET_ WET_ WET_ DELU DELU DELU DELU DELU DELU DELU EQPM HEAD PIPE MBND MCUT PATT EQUP HEAD HEAD HEAD HEAD HEAD HEAD PIPE EQUP HEAD HEAD HEAD HEAD HEAD HEAD EQPM HEAD PIPE ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ PNDT CONC RECD SIDE UPRT ____ ____ ____ PNDT CONC RECD SIDE UPRT EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST 10 10 10 130 10 10 10 130 249 249 249 10 130 130 130 130 130 130 130 10 130 130 130 130 130 130 Continuous Continuous Continuous FM_200 Continuous Continuous Continuous INERGEN Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous SP_EX Continuous Continuous Continuous Continuous Continuous Continuous Continuous Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Existing Fm 200 System Existing Fm 200 Equipment Existing Fm 200 Head Existing Fm 200 Sprinkler Piping Existing Inergen System Existing Inergen Equipment Existing Inergen Head Existing Inergen Piping Existing Materials Beyond Section Cut Existing Materials Cut By Section Existing Textures And Patterns Existing Wet Sprinkler Equipment Existing Wet Sprinkler Heads Existing Wet Sprinkler Pendant Heads Existing Wet Sprinkler Concealed Heads Existing Wet Sprinkler Recessed Heads Existing Wet Sprinkler sidewall Heads Existing Wet Sprinkler Upright Heads Existing Wet Sprinkler Piping Existing Deluge Sprinkler Equipment Existing Deluge Sprinkler Heads Existing Deluge Sprinkler Pendant Heads Existing Deluge Sprinkler Concealed Heads Existing Deluge Sprinkler Recessed Heads Existing Deluge Sprinkler Sidewall Heads Existing Deluge Sprinkler Upright Heads CO2_ CO2_ CO2_ CO2_ EQPM HEAD PIPE ____ ____ ____ ____ EXST EXST EXST EXST 10 10 10 130 Continuous Continuous Continuous CO2 Yes Yes Yes Yes Existing Co2 System Existing Co2 Equipment Existing Co2 Head Existing Co2 Sprinkler Piping DETL DETL DETL DETL ELEV ELEV ELEV ELEV ELEV PUMP STRC VENT WIRE FIXT IDEN OTLN PATT PFIX ____ ____ ____ ____ ____ ____ ____ ____ ____ EXST EXST EXST EXST EXST EXST EXST EXST EXST 72 191 15 53 240 46 249 249 53 Continuous Continuous Dashed Continuous Continuous Continuous Continuous Continuous Continuous Yes Yes Yes Yes Yes Yes Yes Yes Yes Existing Pumps And Compressors Existing Structural Support Features Existing Vents Existing Electrical Wiring Existing Miscellaneous Fixtures Existing Component Identification Numbers Existing Building Outlines Existing Textures And Patterns Existing Plumbing Fixtures

ELEVATIONS

INERGEN

SECTIONS

SPRINKLER

Last Updated: March 2010

Page 178

Engineering Department Manual


E/A Design Division CAD Standard
F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F DELU DRYC DRYC DRYC DRYC DRYC DRYC DRYC DRYC DRY_ DRY_ DRY_ DRY_ DRY_ DRY_ DRY_ DRY_ FOAM FOAM FOAM FOAM FOAM FOAM FOAM FOAM PREA PREA PREA PREA PREA PREA PREA PREA SPKL PIPE EQUP HEAD HEAD HEAD HEAD HEAD HEAD PIPE EQUP HEAD HEAD HEAD HEAD HEAD HEAD PIPE EQUP HEAD HEAD HEAD HEAD HEAD HEAD PIPE EQUP HEAD HEAD HEAD HEAD HEAD HEAD PIPE TEXT ____ ____ ____ PNDT CONC RECD SIDE UPRT ____ ____ ____ PNDT CONC RECD SIDE UPRT ____ ____ ____ PNDT CONC RECD SIDE UPRT ____ ____ ____ PNDT CONC RECD SIDE UPRT ____ ____ EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST 130 10 130 130 130 130 130 130 130 10 130 130 130 130 130 130 130 10 130 130 130 130 130 130 130 10 130 130 130 130 130 130 130 53 DEL Continuous Continuous Continuous Continuous Continuous Continuous Continuous DRY_CHEM Continuous Continuous Continuous Continuous Continuous Continuous Continuous DRY Continuous Continuous Continuous Continuous Continuous Continuous Continuous FOAM Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Existing Deluge Sprinkler Piping Existing Dry Chemical Sprinkler Equipment Existing Dry Chemical Sprinkler Heads Existing Dry Chemical Sprinkler Pendant Heads Existing Dry Chemical Sprinkler Concealed Heads Existing Dry Chemical Sprinkler Recessed Heads Existing Dry Chemical Sprinkler Sidewall Heads Existing Dry Chemical Sprinkler Upright Heads Existing Dry Chemical Sprinkler Piping Existing Dry Sprinkler Equipment Existing Dry Sprinkler Heads Existing Dry Sprinkler Pendant Heads Existing Dry Sprinkler Concealed Heads Existing Dry Sprinkler Recessed Heads Existing Dry Sprinkler Sidewall Heads Existing Dry Sprinkler Upright Heads Existing Dry Sprinkler Piping Existing Foam Sprinkler Equipment Existing Foam Sprinkler Heads Existing Foam Sprinkler Pendant Heads Existing Foam Sprinkler Concealed Heads Existing Foam Sprinkler Recessed Heads Existing Foam Sprinkler Sidewall Heads Existing Foam Sprinkler Upright Heads Existing Foam Sprinkler Piping Existing Pre-Action Sprinkler Equipment Existing Pre-Action Sprinkler Heads Existing Pre-Action Sprinkler Pendant Heads Existing Pre-Action Sprinkler Concealed Heads Existing Pre-Action Sprinkler Recessed Heads Existing Pre-Action Sprinkler Sidewall Heads Existing Pre-Action Sprinkler Upright Heads Existing Pre-Action Sprinkler Piping Existing Fire Protection Annotations

6.22.2.9

FIRE PROTECTION FUTURE WORK

Discipline

Linetype

Phase

Minor

Major

Color

Plots

Desc

Description

Default Future Layer Properties (Unless Otherwise Noted Below) F ____ ____ ____ FUTR Continuous Yes

Last Updated: March 2010

Page 179

Engineering Department Manual


E/A Design Division CAD Standard
ANNOTATION F F F F F F F F F F F F F F F F F F F CO2 F F F F FM200 F F F F F F F F F F F F F F FM2_ FM2_ FM2_ FM2_ INGN INGN INGN INGN SECT SECT SECT WET_ WET_ WET_ EQPM HEAD PIPE MBND MCUT PATT EQUP HEAD HEAD EQPM HEAD PIPE ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ PNDT FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR 10 10 10 130 10 10 10 130 249 249 249 10 130 130 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Future Fm 200 System Future Fm 200 Equipment Future Fm 200 Head Future Fm 200 Sprinkler Piping Future Inergen System Future Inergen Equipment Future Inergen Head Future Inergen Piping Future Materials Beyond Section Cut Future Materials Cut By Section Future Textures And Patterns Future Wet Sprinkler Equipment Future Wet Sprinkler Heads Future Wet Sprinkler Pendant Heads CO2_ CO2_ CO2_ CO2_ EQPM HEAD PIPE ____ ____ ____ ____ FUTR FUTR FUTR FUTR 10 10 10 130 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 Yes Yes Yes Yes Future Co2 System Future Co2 Equipment Future Co2 Head Future Co2 Sprinkler Piping ANNO ANNO ANNO DETL DETL DETL DETL DETL DETL DETL DETL DETL DETL DETL ELEV ELEV ELEV ELEV ELEV DIMS NOTE TEXT CABS DUCT EQPT FANS GENF GRLS LVLE PUMP STRC VENT WIRE FIXT IDEN OTLN PATT PFIX ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR 8 2 2 249 131 92 92 234 131 72 72 191 15 53 240 46 249 249 53 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Future Dimensions Future General Notes And Remarks Future Miscellaneous Annotations Future Hose Cabinets Future Ducts Future Equipment And Fixtures Future Fans Future General Features Future Grilles And Louvers Future Valves And Fittings Future Pumps And Compressors Future Structural Support Features Future Vents Future Electrical Wiring Future Miscellaneous Fixtures Future Component Identification Numbers Future Building Outlines Future Textures And Patterns Future Plumbing Fixtures

DETAIL

ELEVATIONS

INERGEN

SECTIONS

SPRINKLER

Last Updated: March 2010

Page 180

Engineering Department Manual


E/A Design Division CAD Standard
F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F WET_ WET_ WET_ WET_ WET_ DELU DELU DELU DELU DELU DELU DELU DELU DRYC DRYC DRYC DRYC DRYC DRYC DRYC DRYC DRY_ DRY_ DRY_ DRY_ DRY_ DRY_ DRY_ DRY_ FOAM FOAM FOAM FOAM FOAM FOAM FOAM FOAM PREA PREA PREA PREA PREA PREA PREA PREA HEAD HEAD HEAD HEAD PIPE EQUP HEAD HEAD HEAD HEAD HEAD HEAD PIPE EQUP HEAD HEAD HEAD HEAD HEAD HEAD PIPE EQUP HEAD HEAD HEAD HEAD HEAD HEAD PIPE EQUP HEAD HEAD HEAD HEAD HEAD HEAD PIPE EQUP HEAD HEAD HEAD HEAD HEAD HEAD PIPE CONC RECD SIDE UPRT ____ ____ ____ PNDT CONC RECD SIDE UPRT ____ ____ ____ PNDT CONC RECD SIDE UPRT ____ ____ ____ PNDT CONC RECD SIDE UPRT ____ ____ ____ PNDT CONC RECD SIDE UPRT ____ ____ ____ PNDT CONC RECD SIDE UPRT ____ FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR 130 130 130 130 130 10 130 130 130 130 130 130 130 10 130 130 130 130 130 130 130 10 130 130 130 130 130 130 130 10 130 130 130 130 130 130 130 10 130 130 130 130 130 130 130 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 HIDDEN2 Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Future Wet Sprinkler Concealed Heads Future Wet Sprinkler Recessed Heads Future Wet Sprinkler sidewall Heads Future Wet Sprinkler Upright Heads Future Wet Sprinkler Piping Future Deluge Sprinkler Equipment Future Deluge Sprinkler Heads Future Deluge Sprinkler Pendant Heads Future Deluge Sprinkler Concealed Heads Future Deluge Sprinkler Recessed Heads Future Deluge Sprinkler Sidewall Heads Future Deluge Sprinkler Upright Heads Future Deluge Sprinkler Piping Future Dry Chemical Sprinkler Equipment Future Dry Chemical Sprinkler Heads Future Dry Chemical Sprinkler Pendant Heads Future Dry Chemical Sprinkler Concealed Heads Future Dry Chemical Sprinkler Recessed Heads Future Dry Chemical Sprinkler Sidewall Heads Future Dry Chemical Sprinkler Upright Heads Future Dry Chemical Sprinkler Piping Future Dry Sprinkler Equipment Future Dry Sprinkler Heads Future Dry Sprinkler Pendant Heads Future Dry Sprinkler Concealed Heads Future Dry Sprinkler Recessed Heads Future Dry Sprinkler Sidewall Heads Future Dry Sprinkler Upright Heads Future Dry Sprinkler Piping Future Foam Sprinkler Equipment Future Foam Sprinkler Heads Future Foam Sprinkler Pendant Heads Future Foam Sprinkler Concealed Heads Future Foam Sprinkler Recessed Heads Future Foam Sprinkler Sidewall Heads Future Foam Sprinkler Upright Heads Future Foam Sprinkler Piping Future Pre-Action Sprinkler Equipment Future Pre-Action Sprinkler Heads Future Pre-Action Sprinkler Pendant Heads Future Pre-Action Sprinkler Concealed Heads Future Pre-Action Sprinkler Recessed Heads Future Pre-Action Sprinkler Sidewall Heads Future Pre-Action Sprinkler Upright Heads Future Pre-Action Sprinkler Piping

Last Updated: March 2010

Page 181

Engineering Department Manual


E/A Design Division CAD Standard
F SPKL TEXT ____ FUTR 53 HIDDEN2 Yes Future Fire Protection Annotations

6.22.2.10
Discipline Major

FIRE PROTECTION RELOCATED WORK


Linetype Phase Minor Color

Plots

Desc

Description

Default Future Layer Properties (Unless Otherwise Noted Below) F RELO ____ ____ ____ 20 Continuous Yes GENERAL F PLAN ____ ____ RELO 20 Continuous Yes F PLAN FINE ____ RELO 22 Continuous Yes F DETL ____ ____ RELO 20 Continuous Yes F ELEV ____ ____ RELO 20 Continuous Yes F ELEV FINE ____ RELO 22 Continuous Yes

Relocated Elements in Plan Relocated Elements in Plan (Thin Line) Relocated Elements in Details Relocated Elements in Elevation or Section Relocated Elements in Plan (Thin Line)

6.22.2.11
Discipline

FIRE PROTECTION REMOVAL WORK

Linetype

Phase

Minor

Major

Color

Plots

Desc

Description

Default Removal Layer Properties (Unless Otherwise Noted Below) F ____ ____ ____ RMVL Continuous X REMOVALS MECHANICAL_ F PLAN GRFX ____ RMVL 170 REMOVAL2 MECHANICAL_ F PLAN GRFX SHRT RMVL 170 REMOVAL2_s ANNOTATION F ANNO DIMS ____ RMVL 8 Continuous F ANNO NOTE ____ RMVL 2 Continuous F ANNO TEXT ____ RMVL 2 Continuous DETAIL F DETL CABS ____ RMVL 7 Continuous F DETL DUCT ____ RMVL 140 Continuous F DETL EQPT ____ RMVL 90 Continuous F DETL FANS ____ RMVL 90 Continuous F DETL GENF ____ RMVL 243 Continuous F DETL GRLS ____ RMVL 140 Continuous F DETL LVLE ____ RMVL 60 Continuous F DETL PUMP ____ RMVL 60 Continuous F DETL STRC ____ RMVL 170 Continuous F DETL VENT ____ RMVL 35 Dashed F DETL WIRE ____ RMVL 83 Continuous ELEVATIONS F ELEV FIXT ____ RMVL 241 Continuous F ELEV IDEN ____ RMVL 9 Continuous

Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Draw Over RMVL Linework Normal Spacing Draw Over RMVL Linework Short Spacing Removal Of Dimensions Removal Of General Notes And Remarks Removal Of Miscellaneous Annotations Removal Of Hose Cabinets Removal Of Ducts Removal Of Equipment And Fixtures Removal Of Fans Removal Of General Features Removal Of Grilles And Louvers Removal Of Valves And Fittings Removal Of Pumps And Compressors Removal Of Structural Support Features Removal Of Vents Removal Of Electrical Wiring Removal Of Miscellaneous Fixtures Removal Of Component Identification Number

Last Updated: March 2010

Page 182

Engineering Department Manual


E/A Design Division CAD Standard
F ELEV F ELEV F ELEV CO2 F CO2_ F CO2_ F CO2_ F CO2_ FM200 F FM2_ F FM2_ F FM2_ F FM2_ INERGEN F INGN F INGN F INGN F INGN SECTIONS F SECT F SECT F SECT F SECT SPRINKLER F WET_ F WET_ F WET_ F WET_ F WET_ F WET_ F WET_ F WET_ F DELU F DELU F DELU F DELU F DELU F DELU F DELU F DELU F DRYC F DRYC F DRYC F DRYC F DRYC F DRYC F DRYC F DRYC F DRY_ F DRY_ F DRY_ OTLN PATT PFIX ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ PNDT CONC RECD SIDE UPRT ____ ____ ____ PNDT CONC RECD SIDE UPRT ____ ____ ____ PNDT CONC RECD SIDE UPRT ____ ____ ____ PNDT RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL 7 7 2 231 231 231 131 231 231 231 131 231 231 231 131 Continuous Continuous Continuous Continuous Continuous Continuous CO2 Continuous Continuous Continuous FM_200 Continuous Continuous Continuous INERGEN Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Removal Of Building Outlines Removal Of Textures And Patterns Removal Of Plumbing Fixtures Removal Of Co2 System Removal Of Co2 Equipment Removal Of Co2 Head Removal Of Co2 Sprinkler Piping Removal Of Fm 200 System Removal Of Fm 200 Equipment Removal Of Fm 200 Head Removal Of Fm 200 Sprinkler Piping Removal Of Inergen System Removal Of Inergen Equipment Removal Of Inergen Head Removal Of Inergen Piping

EQPM HEAD PIPE

EQPM HEAD PIPE

EQPM HEAD PIPE IDEN MBND MCUT PATT EQUP HEAD HEAD HEAD HEAD HEAD HEAD PIPE EQUP HEAD HEAD HEAD HEAD HEAD HEAD PIPE EQUP HEAD HEAD HEAD HEAD HEAD HEAD PIPE EQUP HEAD HEAD

7 7 7 231 131 131 131 131 131 131 131 231 131 131 131 131 131 131 131 231 131 131 131 131 131 131 131 231 131 131

Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous SP Continuous Continuous Continuous Continuous Continuous Continuous Continuous DEL Continuous Continuous Continuous Continuous Continuous Continuous Continuous DRY_CHEM Continuous Continuous Continuous

Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

Removal Of Materials Beyond Section Cut Removal Of Materials Cut By Section Removal Of Textures And Patterns Removal Of Wet Sprinkler Equipment Removal Of Wet Sprinkler Heads Removal Of Wet Sprinkler Pendant Heads Removal Of Wet Sprinkler Concealed Heads Removal Of Wet Sprinkler Recessed Heads Removal Of Wet Sprinkler Sidewall Heads Removal Of Wet Sprinkler Upright Heads Removal Of Wet Sprinkler Piping Removal Of Deluge Sprinkler Equipment Removal Of Deluge Sprinkler Heads Removal Of Deluge Sprinkler Pendant Heads Removal Of Deluge Sprnk Concealed Heads Removal Of Deluge Sprinkler Recessed Heads Removal Of Deluge Sprinkler Sidewall Heads Removal Of Deluge Sprinkler Upright Heads Removal Of Deluge Sprinkler Piping Removal Of Dry Chemical Sprinkler Equipment Removal Of Dry Chemical Sprinkler Heads Removal Of Dry Chem. Sprnk. Pendant Heads Removal Of Dry Chem. Sprnk. Concealed Heads Removal Of Dry Chem. Sprnk. Recessed Heads Removal Of Dry Chem. Sprnk. Sidewall Heads Removal Of Dry Chem. Sprnk. Upright Heads Removal Of Dry Chemical Sprinkler Piping Removal Of Dry Sprinkler Equipment Removal Of Dry Sprinkler Heads Removal Of Dry Sprinkler Pendant Heads

Last Updated: March 2010

Page 183

Engineering Department Manual


E/A Design Division CAD Standard
F F F F F F F F F F F F F F F F F F F F F F DRY_ DRY_ DRY_ DRY_ DRY_ FOAM FOAM FOAM FOAM FOAM FOAM FOAM FOAM PREA PREA PREA PREA PREA PREA PREA PREA SPKL HEAD HEAD HEAD HEAD PIPE EQUP HEAD HEAD HEAD HEAD HEAD HEAD PIPE EQUP HEAD HEAD HEAD HEAD HEAD HEAD PIPE TEXT CONC RECD SIDE UPRT ____ ____ ____ PNDT CONC RECD SIDE UPRT ____ ____ ____ PNDT CONC RECD SIDE UPRT ____ ____ RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL 131 131 131 131 131 231 131 131 131 131 131 131 131 231 131 131 131 131 131 131 131 2 Continuous Continuous Continuous Continuous DRY Continuous Continuous Continuous Continuous Continuous Continuous Continuous FOAM Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Removal Of Dry Sprinkler Concealed Heads Removal Of Dry Sprinkler Recessed Heads Removal Of Dry Sprinkler Sidewall Heads Removal Of Dry Sprinkler Upright Heads Removal Of Dry Sprinkler Piping Removal Of Foam Sprinkler Equipment Removal Of Foam Sprinkler Heads Removal Of Foam Sprinkler Pendant Heads Removal Of Foam Sprinkler Concealed Heads Removal Of Foam Sprinkler Recessed Heads Removal Of Foam Sprinkler Sidewall Heads Removal Of Foam Sprinkler Upright Heads Removal Of Foam Sprinkler Piping Removal Of Pre-Action Sprinkler Equipment Removal Of Pre-Action Sprinkler Heads Removal Of Pre-Action Sprnk. Pendant Heads Removal Of Pre-Action Sprnk. Concealed Heads Removal Of Pre-Action Sprnk. Recessed Heads Removal Of Pre-Action Sprnk. Sidewall Heads Removal Of Pre-Action Sprnk. Upright Heads Removal Of Pre-Action Sprinkler Piping Removal Of Fire Protection Annotations

6.22.2.12
Discipline

FIRE PROTECTION TEMPORARY WORK


Linetype

Phase

Minor

Major

Color

Plots

Desc

Description

Default Temporary Layer Properties (Unless Otherwise Noted Below) F TEMP ____ ____ ____ 234 Continuous Yes GENERAL F F F F F PLAN PLAN DETL ELEV ELEV ____ FINE ____ ____ FINE ____ ____ ____ ____ ____ TEMP TEMP TEMP TEMP TEMP 234 244 234 234 244 Continuous Continuous Continuous Continuous Continuous Yes Yes Yes Yes Yes Temporary Elements in Plan Temporary Elements in Plan (Thin Line) Temporary Elements in Details Temporary Elements in Elevation or Sections Temporary Elements in Plan (Thin Line)

6.22.2.13
Discipline

PLUMBING NEW WORK


Linetype

Phase

Minor

Major

Color

Plots

Desc

Description

ACID P P

ACID ACID

EQPM PIPE

131 131

Continuous Acid

Yes Yes

Acid, Alkaline and Oil Waste Equipment Acid, Alkaline and Oil Waste Piping

Last Updated: March 2010

Page 184

Engineering Department Manual


E/A Design Division CAD Standard
ANNOTATION P ANNO CHNG P ANNO DIMS P ANNO KEYN P ANNO MLIN P ANNO NOTE P ANNO NPLT P ANNO SUBT P ANNO SYMB P ANNO TEXT P ANNO TITL P ANNO TTLB P ANNO VPRT AIR P CAIR P CAIR EQPM DETAIL P DETL EQPM DOMESTIC WATER P DOMW P DOMW COLD P DOMW EQPM P DOMW HOT_ P DOMW PIPE P DOMW PIPE P DOMW RETN P DOMW TEMP ELEVATIONS P ELEV IDEN P ELEV OTLN P ELEV PATT P ELEV PFIX FIRE STANDPIPE P FSP_ PIPE GAS P GAS EQPM P GAS PIPE IRRIGATION SYSTEM P IRRG COVR P IRRG EQPM P IRRG PIPE P IRRG PIPE P IRRG PIPE P IRRG SPKL P IRRG SPKL P IRRG TEXT MISCELLANEOUS P MISC SKID P MISC BKGD P MISC HTRC OIL

2 8 2 6 2 8 131 2 2 6 2 7 30 1 3 170 170 1 170 170 170 170 170 2 7 7 51 170 1 40 42 60 121 121 121 42 42 2 30 7 26

Divide Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous A Continuous Continuous Continuous DCW Continuous DHW Continuous Continuous DHWR T Continuous Continuous Continuous Continuous FSP Continuous G Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Hidden2 Continuous HTRACE

Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

Identification of Updated Work Dimensions Keynotes Match Lines General Notes and Remarks Construction and Reference Lines Subtitles Miscellaneous Symbols Miscellaneous Annotations Titles Borders View Ports Compressed Air Features Compressed Air Equipment Equipment and Fixtures Domestic Hot and Cold Water Systems Domestic Cold Water Piping Domestic Hot and Cold Water Equipment Domestic Hot Water Piping Domestic Water Piping (Schematic) Domestic Water Piping Domestic Hot Water Return Piping Domestic Water Tempered Water Component Identification Numbers Building Outlines Textures and Patterns Plumbing Fixtures Fire Standpipe Piping Gas Equipment Gas Piping Irrigation Coverage and Spray Distribution Patterns Irrigation Equipment Main Irrigation Pipe Line Irrigation Piping Sleeve Irrigation Piping Zone Sprinklers - Fixed Spray Sprinklers - Side Walk Irrigation Annotation Skid Pad Background Features Heat Tacing (Draw Over Linework)

DBLN

MAIN SLEV ZONE _FIX SIDE

Last Updated: March 2010

Page 185

Engineering Department Manual


E/A Design Division CAD Standard
P OIL_ P OIL_ SANITARY P SSWR P SSWR P SSWR P SSWR P SSWR P SSWR P SSWR P SSWR P SSWR P SSWR SECTIONS P SECT P SECT P SECT P SECT STORM P P P P P P P P P VENT DRAN DRAN DRAN DRAN DRAN DRAN DRAN DRAN DRAN EQPM PIPE 1 32 141 141 10 10 51 1 141 50 51 51 2 7 7 7 141 141 10 10 141 50 51 51 1 32 51 7 7 Continuous OW SAN SANU Continuous Continuous Continuous Continuous SAN Continuous Continuous Continuous Continuous Continuous Continuous Continuous ST STU Continuous Continuous ST Continuous Continuous Continuous Continuous VENT Continuous Continuous Continuous Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Oil Equipment Oil Piping Sanitary Sewer Systems Sanitary Sewer Underground Sanitary Sewer Equipment (Schematic) Sanitary Sewer Equipment Sanitary Sewer Plumbing Fixtures Sanitary Sewer Floor Drains Sanitary Sewer Piping (Schematic) Sanitary Sewer Piping 4 Inch or Under Diameter Sanitary Sewer Piping Over 4 Inch Diameter Sanitary Sewer Risers Component Identification Numbers Materials Beyond Section Cut Materials Cut By Section Textures and Patterns Storm Drainage System Storm Drainage System Underground Storm Drainage Equipment (Schematic) Storm Drainage Equipment Storm Drainage Piping (Schematic) Storm Drainage Piping 4 Inch or Under Diameter Storm Drainage Piping Over 4 Inch Diameter Storm Drainage Risers Storm Drainage Roof Drains Vent System Piping Vent Riser External Reference Drawings Raster Images

BELW EQPM EQPM FIXT FLDR PIPE PIPE PIPE RISR IDEN MBND MCUT PATT

DBLN

SML_ LRG_

BELW EQPM EQPM PIPE PIPE PIPE RISR ROOF PIPE RISR

DBLN SML_ LRG_

P VENT P VENT XREF P P XREF XREF

RAST

6.22.2.14
Discipline

PLUMBING EXISTING WORK


Linetype

Phase

Minor

Major

Color

Plots

Desc

Description

Default Existing Layer Properties (Unless Otherwise Noted Below) P ____ ____ ____ EXST Continuous Yes ACID P ACID P ACID ANNOTATION P ANNO P ANNO EQPM PIPE DIMS NOTE ____ ____ ____ ____ EXST EXST EXST EXST 130 130 8 2 Continuous ACID_EX Continuous Continuous Yes Yes Yes Yes Existing Acid, Alkaline And Oil Waste Equipment Existing Acid, Alkaline And Oil Waste Piping Existing Dimensions Existing General Notes And Remarks

Last Updated: March 2010

Page 186

Engineering Department Manual


E/A Design Division CAD Standard
P ANNO TEXT AIR P CAIR P CAIR EQPM DETAIL P DETL EQPM DOMESTIC WATER P DOMW P DOMW COLD P DOMW EQPM P DOMW HOT_ P DOMW PIPE P DOMW PIPE P DOMW RETN P DOMW TEMP ELEVATIONS P ELEV IDEN P ELEV OTLN P ELEV PATT P ELEV PFIX FIRE STANDPIPE P FSP_ PIPE GAS P GAS EQPM P GAS PIPE IRRIGATION SYSTEM P IRRG COVR ____ ____ ____ ____ ____ ____ ____ ____ ____ DBLN ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ MAIN SLEV ZONE _FIX SIDE ____ ____ ____ ____ ____ ____ ____ ____ ____ DBLN ____ ____ ____ SML_ EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST 2 15 10 92 191 191 10 191 191 191 191 191 2 249 249 53 191 10 41 46 72 121 121 121 46 46 2 15 249 Continuous A Continuous Continuous Continuous DCW_EX Continuous DHW_EX Continuous Continuous DHWR_EX T_EX Continuous Continuous Continuous Continuous FSP_EX Continuous G_EX Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Hidden2 Continuous Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Existing Miscellaneous Annotations Existing Compressed Air Features Existing Compressed Air Equipment Existing Equipment And Fixtures Existing Domestic Hot And Cold Water Systems Existing Domestic Cold Water Piping Existing Domestic Hot And Cold Water Equipment Existing Domestic Hot Water Piping Existing Domestic Water Piping (Schematic) Existing Domestic Water Piping Existing Domestic Hot Water Return Piping Existing Domestic Water Tempered Water Existing Component Identification Numbers Existing Building Outlines Existing Textures And Patterns Existing Plumbing Fixtures Existing Fire Standpipe Piping Existing Gas Equipment Existing Gas Piping Existing Irrigation Coverage And Spray Distribution Patterns Existing Irrigation Equipment Existing Main Irrigation Pipe Line Existing Irrigation Piping Sleeve Existing Irrigation Piping Zone Existing Sprinklers - Fixed Spray Existing Sprinklers - Side Walk Existing Irrigation Annotation Existing Skid Pad Existing Background Features

P IRRG EQPM P IRRG PIPE P IRRG PIPE P IRRG PIPE P IRRG SPKL P IRRG SPKL P IRRG TEXT MISCELLANEOUS P MISC SKID P MISC BKGD P MISC HTRC OIL P OIL_ EQPM P OIL_ PIPE SANITARY P SSWR P SSWR BELW P SSWR EQPM P SSWR EQPM P SSWR FIXT P SSWR FLDR P SSWR PIPE P SSWR PIPE

10 41 142 142 240 240 53 10 142 53

Continuous OW SAN_EX SANU_EX Continuous Continuous Continuous Continuous SAN_EX Continuous

Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

Existing Oil Equipment Existing Oil Piping Existing Sanitary Sewer Systems Existing Sanitary Sewer Underground Existing Sanitary Sewer Equipment (Schematic) Existing Sanitary Sewer Equipment Existing Sanitary Sewer Plumbing Fixtures Existing Sanitary Sewer Floor Drains Existing Sanitary Sewer Piping (Schematic) Existing Sanitary Sewer Piping 4 Inch Or Under Diameter

Last Updated: March 2010

Page 187

Engineering Department Manual


E/A Design Division CAD Standard
P SSWR P SSWR SECTIONS P SECT P SECT P SECT P SECT STORM P P P P P P P P P VENT P P DRAN DRAN DRAN DRAN DRAN DRAN DRAN DRAN DRAN VENT VENT PIPE RISR IDEN MBND MCUT PATT LRG_ ____ ____ ____ ____ ____ ____ ____ ____ DBLN ____ SML_ LRG_ ____ ____ ____ ____ EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST 53 53 2 249 249 249 142 142 240 240 142 53 53 53 10 41 53 Continuous Continuous Continuous Continuous Continuous Continuous ST_EX STU_EX Continuous Continuous ST_EX Continuous Continuous Continuous Continuous VENT Continuous Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Existing Sanitary Sewer Piping Over 4 Inch Diameter Existing Sanitary Sewer Risers Existing Component Identification Numbers Existing Materials Beyond Section Cut Existing Materials Cut By Section Existing Textures And Patterns Existing Storm Drainage System Existing Storm Drainage System Underground Existing Storm Drainage Equipment (Schematic) Existing Storm Drainage Equipment Existing Storm Drainage Piping (Schematic) Existing Storm Drainage Piping 4 Inch Or Under Diameter Existing Storm Drainage Piping Over 4 Inch Diameter Existing Storm Drainage Risers Existing Storm Drainage Roof Drains Existing Vent System Piping Existing Vent Riser

BELW EQPM EQPM PIPE PIPE PIPE RISR ROOF PIPE RISR

6.22.2.15
Discipline

PLUMBING FUTURE WORK


Linetype

Phase

Minor

Major

Color

Plots

Desc

Description

Default Future Layer Properties (Unless Otherwise Noted Below) P ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ DBLN ____ ____ FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR 130 130 8 2 2 15 10 92 191 191 10 191 191 191 191 191 Continuous Continuous Acid Continuous Continuous Continuous A Continuous Continuous Continuous DCW Continuous DHW Continuous Continuous DHWR T Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Future Acid, Alkaline And Oil Waste Equipment Future Acid, Alkaline And Oil Waste Piping Future Dimensions Future General Notes And Remarks Future Miscellaneous Annotations Future Compressed Air Features Future Compressed Air Equipment Future Equipment And Fixtures Future Domestic Hot And Cold Water Systems Future Domestic Cold Water Piping Future Domestic Hot And Cold Water Equipment Future Domestic Hot Water Piping Future Domestic Water Piping (Schematic) Future Domestic Water Piping Future Domestic Hot Water Return Piping Future Domestic Water Tempered Water ACID P ACID EQPM P ACID PIPE ANNOTATION P ANNO DIMS P ANNO NOTE P ANNO TEXT AIR P CAIR ____ P CAIR EQPM DETAIL P DETL EQPM DOMESTIC WATER P DOMW ____ P DOMW COLD P DOMW EQPM P DOMW HOT_ P DOMW PIPE P DOMW PIPE P DOMW RETN P DOMW TEMP

Last Updated: March 2010

Page 188

Engineering Department Manual


E/A Design Division CAD Standard
ELEVATIONS P ELEV IDEN P ELEV OTLN P ELEV PATT P ELEV PFIX FIRE STANDPIPE P FSP_ PIPE GAS P GAS EQPM P GAS PIPE IRRIGATION SYSTEM P IRRG COVR

____ ____ ____ ____ ____ ____ ____ ____ ____ MAIN SLEV ZONE _FIX SIDE ____ ____ ____ ____ ____ ____ ____ ____ ____ DBLN ____ ____ ____ SML_ LRG_ ____ ____ ____ ____ ____ ____ ____ ____ DBLN ____ SML_ LRG_

FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR

2 249 249 53 191 10 41 46 72 121 121 121 46 46 2 15 249

Continuous Continuous Continuous Continuous FSP Continuous G Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Hidden2 Continuous

Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

Future Component Identification Numbers Future Building Outlines Future Textures And Patterns Future Plumbing Fixtures Future Fire Standpipe Piping Future Gas Equipment Future Gas Piping Future Irrigation Coverage And Spray Distribution Patterns Future Irrigation Equipment Future Main Irrigation Pipe Line Future Irrigation Piping Sleeve Future Irrigation Piping Zone Future Sprinklers - Fixed Spray Future Sprinklers - Side Walk Future Irrigation Annotation Future Skid Pad Future Background Features

P IRRG EQPM P IRRG PIPE P IRRG PIPE P IRRG PIPE P IRRG SPKL P IRRG SPKL P IRRG TEXT MISCELLANEOUS P MISC SKID P MISC BKGD P MISC HTRC OIL P OIL_ EQPM P OIL_ PIPE SANITARY P SSWR ____ P SSWR BELW P SSWR EQPM P SSWR EQPM P SSWR FIXT P SSWR FLDR P SSWR PIPE P SSWR PIPE P SSWR PIPE P SSWR RISR SECTIONS P SECT IDEN P SECT MBND P SECT MCUT P SECT PATT STORM P DRAN ____ P DRAN BELW P DRAN EQPM P DRAN EQPM P DRAN PIPE P DRAN PIPE P DRAN PIPE

10 41 142 142 240 240 53 10 142 53 53 53 2 249 249 249 142 142 240 240 142 53 53

Continuous OW SAN SANU Continuous Continuous Continuous Continuous SAN Continuous Continuous Continuous Continuous Continuous Continuous Continuous ST STU Continuous Continuous ST Continuous Continuous

Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

Future Oil Equipment Future Oil Piping Future Sanitary Sewer Systems Future Sanitary Sewer Underground Future Sanitary Sewer Equipment (Schematic) Future Sanitary Sewer Equipment Future Sanitary Sewer Plumbing Fixtures Future Sanitary Sewer Floor Drains Future Sanitary Sewer Piping (Schematic) Future Sanitary Sewer Piping 4 Inch Or Under Diameter Future Sanitary Sewer Piping Over 4 Inch Diameter Future Sanitary Sewer Risers Future Component Identification Numbers Future Materials Beyond Section Cut Future Materials Cut By Section Future Textures And Patterns Future Storm Drainage System Future Storm Drainage System Underground Future Storm Drainage Equipment (Schematic) Future Storm Drainage Equipment Future Storm Drainage Piping (Schematic) Future Storm Drainage Piping 4 Inch Or Under Diameter Future Storm Drainage Piping Over 4 Inch Diameter

Last Updated: March 2010

Page 189

Engineering Department Manual


E/A Design Division CAD Standard
P P VENT P P DRAN DRAN VENT VENT RISR ROOF PIPE RISR ____ ____ ____ ____ FUTR FUTR FUTR FUTR 53 10 41 53 Continuous Continuous VENT Continuous Yes Yes Yes Yes Future Storm Drainage Risers Future Storm Drainage Roof Drains Future Vent System Piping Future Vent Riser

6.22.2.16
Discipline

PLUMBING RELOCATED WORK

Linetype

Phase

Minor

Major

Color

Plots

Desc

Description

Default Relocated Layer Properties (Unless Otherwise Noted Below) P P P P P P ____ PLAN PLAN DETL ELEV ELEV ____ ____ FINE ____ ____ FINE ____ ____ ____ ____ ____ ____ RELO RELO RELO RELO RELO RELO 20 20 20 20 20 20 Continuous Continuous Continuous Continuous Continuous Continuous Yes Yes Yes Yes Yes Yes Relocated Elements in Plan Relocated Elements in Plan (Thin Line) Relocated Elements in Details Relocated Elements in Elevation or Section Relocated Elements in Plan (Thin Line) GENERAL

6.22.2.17
Discipline

PLUMBING TEMPORARY WORK


Linetype Phase

Minor

Major

Color

Plots

Desc

Description

Default Temporary Layer Properties (Unless Otherwise Noted Below) P ____ GENERAL P P P P P PLAN PLAN DETL ELEV ELEV ____ ____ FINE ____ ____ FINE ____ ____ ____ ____ ____ ____ TEMP TEMP TEMP TEMP TEMP TEMP 234 20 20 20 20 20 Continuous Continuous Continuous Continuous Continuous Continuous Yes Yes Yes Yes Yes Yes Temporary Elements in Plan Temporary Elements in Plan (Thin Line) Temporary Elements in Details Temporary Elements in Elevation or Sections Temporary Elements in Plan (Thin Line)

Last Updated: March 2010

Page 190

Engineering Department Manual


E/A Design Division CAD Standard

6.22.3 LINETYPES Name


Continuous Description Continuous Example

DASHED

Dashed (1x)

DIVIDE

Divide (1x)

Last Updated: March 2010

Page 191

Engineering Department Manual


E/A Design Division CAD Standard

6.22.4 SYMBOLS 6.22.4.1 HVAC AIR TERMINALS


Symbol Block Name M-Diffuser-1_WAY.dwg Layer Name (Varies) Description Three-Way Blanked Off Supply Diffuser

M-Diffuser-2_WAY.dwg

(Varies)

Two-Way Blanked-Off Supply Air Diffuser

M-Diffuser2_WAY_CORNER.dwg

(Varies)

Two-Way Supply Diffuser with Blanked-Off Corner

M-Diffuser-3_WAY.dwg

(Varies)

One-Way Blanked-Off Supply Air Diffuser

M-Diffuser-4_WAY.dwg

(Varies)

Supply Air Diffuser

M-Diffuser-R-1x1.dwg

(Varies)

Return Air Register

6.22.4.2
Symbol

HVAC CONTROL DEVICES


Block Name DUCT SMOKE DETECTOR.dwg Layer Name (Varies) Description Duct Smoke Detector

FIRESTAT.dwg

(Varies)

Firestat

FLOW SWITCH.dwg

(Varies)

Flow Switch

FREEZESTAT.dwg

(Varies)

Freezstat

HEAT DETECTOR.dwg

(Varies)

Heat Detector

Last Updated: March 2010

Page 192

Engineering Department Manual


E/A Design Division CAD Standard

HUMIDISTAT.dwg

(Varies)

Humidistat

M-FLOW_METER.dwg

(Varies)

Flow Meter

M-FLOW_TRNSMTR.dwg

(Varies)

Flow Transmitter

M-LEAK_DETECTOR.dwg

(Varies)

Leak Detector Symbol

M-MOTOR.dwg

(Varies)

Motor

M-SMOKE_DETECTOR.dwg

(Varies)

Smoke Detector (Duct)

M-STEAM_TRAP.dwg

(Varies)

Steam Trap

M-TEMP_SNSR.dwg

(Varies)

Temperature Sensor

M-TEMPERATURE_SENSOR.dwg

(Varies)

Temperature Sensor

M-THERMOSTAT.dwg

(Varies)

Thermostat

MTHERMST_HUMIDIST_SWITCH.dwg

(Varies)

Thermostat/Humidistat Switch

SPACE TEMPERATURE SENSOR.dwg

(Varies)

Space Temperature Sensor

TEMPERATURE SENSOR.dwg

(Varies)

Temperature Sensor

Last Updated: March 2010

Page 193

Engineering Department Manual


E/A Design Division CAD Standard

THERMOSTAT, ELECTRIC.dwg

(Varies)

Electric Thermostat

THERMOSTAT, PNEUMATIC.dwg

(Varies)

Pneumatic Thermostat

6.22.4.3
Symbol

HVAC DRAFTING CONVENTIONS


Block Name M-ARROW.dwg Layer Name (Varies) Description Airflow Directional Arrow

M-ARROW_LEADER.dwg

(Varies)

Leader to be Used with Thermostat Symbol

M-BREAK.dwg

(Varies)

Duct Break

M-BREAK_LINE1.dwg

(Varies)

Break Line

M-BREAK_LINE2.dwg

(Varies)

Break Symbol for Single Line Ducts and Pipes

M-CALLOUT.dwg

(Varies)

Callout for Plans

M-CALLOUT-SYM.DWG

(Varies)

Detail, Section, & Elevation Symbol for Plans

M-CENTERLINE_SYM.DWG

(Varies)

Centerline Symbol

M-CUT2.dwg

(Varies)

Detail Symbol for Plans

M-CUT3.dwg

(Varies)

Section Head

Last Updated: March 2010

Page 194

Engineering Department Manual


E/A Design Division CAD Standard

M-CUT4.dwg

(Varies)

Section Line

mec-CALLOUT.dwg

(Varies)

Callout

M-REMOVAL.dwg

(Varies)

Removal Marker

M-REVISION_TRIANGLE.dwg

(Varies)

Revision Triangle

M-SEC-DN-LEFT.dwg

(Varies)

Section, Detail, Elev. Callout

M-SEC-DN-RIGHT.dwg

(Varies)

Section, Detail, Elev. Callout

M-SEC-LEFT-BTM.dwg

(Varies)

Section, Detail, Elev. Callout

M-SEC-LEFT-TOP.dwg

(Varies)

Section, Detail, Elev. Callout

M-SEC-RIGHT-BTM.dwg

(Varies)

Section, Detail, Elev. Callout

M-SEC-RIGHT-TOP.dwg

(Varies)

Section, Detail, Elev. Callout

M-SECTION-MARK.dwg

(Varies)

Section

M-SEC-UP-LEFT.dwg

(Varies)

Section, Detail, Elev. Callout

M-SEC-UP-RIGHT.dwg

(Varies)

Section, Detail, Elev. Callout

Last Updated: March 2010

Page 195

Engineering Department Manual


E/A Design Division CAD Standard 6.22.4.4
Symbol

HVAC DUCTWORK
Block Name ACCESS DOOR IN DUCT.dwg Layer Name (Varies) Description Access Door in Duct

AIR VENT AUTOMATIC.dwg

(Varies)

Automatic Air Vent

AIR VENT MANUAL.dwg

(Varies)

Manual Air Vent

CONTROL.dwg

(Varies)

Control

DUCT FLEXIBLE CONNECTION.dwg

(Varies)

Flexible Duct Connection

FILTER.dwg

(Varies)

Filter

M-ACCESS_DOOR.dwg

(Varies)

Access Door Symbol for Ductwork & Equipment

M-AIR_VENT.dwg

(Varies)

Air Vent

M-COIL_COOLING.dwg

(Varies)

Cooling Coil

M-COIL_HEATING.dwg

(Varies)

Heating Coil

M-COIL_PRE_HT.dwg

(Varies)

Pre-Heating Coil

M-DUCT_FLEX_CONNECT2.dwg

(Varies)

Flex Duct Connection

Last Updated: March 2010

Page 196

Engineering Department Manual


E/A Design Division CAD Standard

M-EXPN_JNT.dwg

(Varies)

Pipe Expansion Joint Symbol

M-FD.dwg

(Varies)

Fire Damper

M-FSD.dwg

(Varies)

Fire Smoke Damper

M-FSD_FD.dwg

(Varies)

Fire Smoke Damper

M-MEASUR_STATION.dwg

(Varies)

Measurement Station

M-SENS_RELAY.dwg

(Varies)

Current Sensing Relay

M-SIGHT_GLASS.dwg

(Varies)

Sight Glass

M-THERMOMETER.dwg

(Varies)

Thermometer

M-VFD.dwg

(Varies)

Variable-Frequency Drive

SIDE CONNECTED SUPPLY, RETURN OR EXHAUST DEVICE.dwg COMBINATION FIRE AND SMOKE DAMPER WITH DUCT ACCESS DOOR.dwg FUSIBLE LINK FIRE DAMPER WITH DUCT ACCESS DOOR.dwg

(Varies)

Side-Connected Supply

(Varies)

Fire and Smoke Damper Combination with Duct Access Door Fusible Link Fire Damper with Duct Access Door Multi-Blade Control Damper with Spring Opposed, Diaphragm Actuator w/o Positioner

(Varies)

M-M_B_CONTR_DAMP1.dwg

(Varies)

Last Updated: March 2010

Page 197

Engineering Department Manual


E/A Design Division CAD Standard
Multi-Blade Control Damper with Spring Diaphragm Actuator and Positioner

M-M_B_CONTR_DAMP.dwg

(Varies)

M-MOTORIZED_DAMPER.dwg

(Varies)

Motorized Damper

MOTORIZED DAMPER.dwg

(Varies)

Motorized Damper

SMOKE DAMPER WITH DUCT ACCESS DOOR.dwg

(Varies)

Smoke Damper with Duct Access Door

SPLITTER DAMPER.dwg

(Varies)

Splitter Damper

VOLUME DAMPER.dwg

(Varies)

Volume Damper

ACCOUSTICAL LINED DUCT.dwg

(Varies)

Accoustical Lined Duct

DUCT SECTION CARRYING RETURN AIR.dwg

(Varies)

Duct Section Carrying Return Air

DUCT SECTION CARRYING SUPPLY AIR.dwg

(Varies)

Duct Section Carrying Supply Air

CONCENTRIC REDUCER.dwg

(Varies)

Concentric Reducer

ECCENTRIC REDUCER.dwg

(Varies)

Eccentric Reducer

ELBOW WITH TURNNG VANES CIR.dwg

(Varies)

Elbow with Circular Turning Vanes

ELBOW WITH TURNING VANES RECT.dwg

(Varies)

Elbow with Rectangular Turning Vanes

Last Updated: March 2010

Page 198

Engineering Department Manual


E/A Design Division CAD Standard

M-DOOR_LOUVERED.DWG

(Varies)

Louvered Door

M-DOOR_UNDERCUT.DWG

(Varies)

Undercut Door

M-DUCT_DN1.dwg

(Varies)

Duct Sloping Down Symbol

M-DUCT_DN.dwg

(Varies)

Duct Sloping Down Symbol

M-DUCT_FLEX_CONNECT1.dwg

(Varies)

Flexible Connection

M-DUCT_UP1.dwg

(Varies)

Raise Duct Up Symbol

M-DUCT_UP.dwg

(Varies)

Raise Duct Up Symbol

SLOPING DROP IN DUCT IN DIRECTION OF ARROW.dwg

(Varies)

Sloping Drop in Duct (Direction of Arrow)

SLOPING RISE IN DUCT IN DIRECTION OF ARROW.dwg

(Varies)

Sloping Rise in Duct (Direction of Arrow)

6.22.4.5
Symbol

HVAC MECHANICAL EQUIPMENT


Block Name AXIAL FAN.dwg Layer Name (Varies) Description Axial Fan

M-FAN.dwg

(Varies)

Centrifugal Fan or Pump Symbol for Diagrams

M-FAN_PROP.dwg

(Varies)

Propeller Fan Symbol

Last Updated: March 2010

Page 199

Engineering Department Manual


E/A Design Division CAD Standard

M-PUMP.dwg

(Varies)

Pump Symbol

M-PUMP_END_SUCT.dwg

(Varies)

End Suction Pump Symbol

M-PUMP_HORIZ_SPLIT.dwg

(Varies)

Horizontal Equal Split Pump Symbol

M-UNIT_HEATER.dwg

(Varies)

Unit Heater

PUMP.dwg

(Varies)

Pump

WALL HYDRANT.dwg

(Varies)

Wall-Mounted Hydrant

6.22.4.6
Symbol

HVAC MISCELLANEOUS
Block Name ARROW INDICATES DIRECTION OF FLOW.dwg Layer Name (Varies) Description Direction of Flow

BALL JOINTS.dwg

(Varies)

Ball Joints

CONCEALED SPRINKLER HEAD.dwg

(Varies)

Concealed Sprinkler Head

DUCT SIZE FIRST SIZE INDICATES PLAN SIZE.dwg

(Varies)

Duct Size

EXISTING SPRINKLER HEAD TO BE REMOVED.dwg

(Varies)

Existing Sprinkler Head to be Removed

M-AIRFLOW_RTN.DWG

(Varies)

Air Flow Directional Arrow (Negative Pressure)

Last Updated: March 2010

Page 200

Engineering Department Manual


E/A Design Division CAD Standard

M-AIRFLOW_SUP.dwg

(Varies)

Air Flow Direction Arrow (Positive Pressure)

M-ARROW_1.dwg

(Varies)

Air Flow Directional Arrow

M-ARROW_FLOW.dwg

(Varies)

Fluid Flow Arrow Symbol

M-CONNECT.dwg

(Varies)

Point of Connection

M-DDC_AI.dwg

(Varies)

DDC Analog Input Signal

M-DDC_AO.dwg

(Varies)

DDC Analog Output Signal

M-DDC_DI.dwg

(Varies)

DDC Digital Input Signal

M-DDC_DO.dwg

(Varies)

DDC Digital Output Signal

M-DDC_SIGNAL_SELECT.dwg

(Varies)

DDC Signal Selector

M-DIFF_PRS_SWTCH.dwg

(Varies)

Pressure Differential Switch

M-DISCONNECT.dwg

(Varies)

Point of Disconnection

M-PIPE_BREAK.dwg

(Varies)

Pipe Break

M-PIPE_RISERBOX.dwg

(Varies)

Riser Box

Last Updated: March 2010

Page 201

Engineering Department Manual


E/A Design Division CAD Standard

M-PIPE_SECTION.dwg

(Varies)

Pipe Riser Symbol

M-POINT_OF_CONNTECTION.dwg

(Varies)

Connection Between Existing and New

M-POINT_OF_DISCONNECTION.dwg

(Varies)

Disconnection of Existing

M-PRS_TRNSMTR.dwg

(Varies)

Pressure Transmitter

M-TAG_EQUIP.dwg

(Varies)

Equipment Tag

SIDEWALL SPRINKLER HEAD.dwg

(Varies)

Sidewall Sprinkler Head

UPRIGHT SPRINKLER HEAD.dwg

(Varies)

Upright Sprinkler Head

6.22.4.7
Symbol

HVAC PIPING
Block Name CAPPED PIPE.dwg Layer Name (Varies) Description Capped Pipe

DIRT POCKET.dwg

(Varies)

Dirty Pocket

DRIP ASSEMBLY.dwg

(Varies)

Drip Assembly

FLOAT & THERMOSTATIC STEAM TRAP WITH BLOWDOWN VALVE.dwg

(Varies)

Float & Thermostatic Steam Trap with Blowdown Valve

M-PIPE_ANCHOR.dwg

(Varies)

Pipe Anchor Symbol

Last Updated: March 2010

Page 202

Engineering Department Manual


E/A Design Division CAD Standard

M-PIPE_STRAINER.dwg

(Varies)

Strainer with Blow-Off Valve

M-PIPE_UNION.dwg

(Varies)

Pipe Union

M-PRESSURE_GAUGE.dwg

(Varies)

Pressure Gauge with Cock

M-REDUCER.dwg

(Varies)

Reducer

PIPE ANCHOR.dwg

(Varies)

Pipe Anchor

PIPE EXPANSION JOINT.dwg

(Varies)

Pipe Expansion Joint

PIPE FLEXIBLE CONNECTION.dwg

(Varies)

Pipe Flexible Connection

PIPE GUIDE.dwg

(Varies)

Pipe Guide

PLUG FOR PRESSURE GAUGE AND THERMOMETER CONNECTION.dwg

(Varies)

Plug for Pressure Gauge and Thermometer Connection

PLUMBING FIXTURE STOP.dwg

(Varies)

Plumbing Fixtures Stop

STRAINER BASKET TYPE.dwg

(Varies)

Strainer Basket Type

STRAINER Y TYPE WITH BLOWDOWN VALVE.dwg

(Varies)

Strainer Y Type with Blowdown Valve

UNION.dwg

(Varies)

Union

Last Updated: March 2010

Page 203

Engineering Department Manual


E/A Design Division CAD Standard

VACUUM BREAKER.dwg

(Varies)

Vacuum Breaker

VALVED CAPPED OUTLET BALL.dwg

(Varies)

Valved, Capped Outlet Ball

VALVED CAPPED OUTLET GATE.dwg

(Varies)

Valved, Capped Outlet Gate

VALVED CAPPED OUTLET PLUG.dwg

(Varies)

Valved, Capped Outlet Plug

VENTURI FLOW METER.dwg

(Varies)

Venturi Flow Meter

M-PIPE_DN.dwg

(Varies)

Pipe Turns Down Symbol

M-PIPE_TAP.dwg

(Varies)

Bottom Tap Pipe Connection

M-PIPE_UP.dwg

(Varies)

Pipe Turns Up Symbol

PIPE DOWN.dwg

(Varies)

Pipe Down

PIPE UP.dwg

(Varies)

Pipe Up

BALL VALVE.dwg

(Varies)

Ball Valve

LOCK-SHIELD VALVE.dwg

(Varies)

Lock-Shield Valve

LUBRICATED PLUG VALVE.dwg

(Varies)

Lubricated Plug Valve

Last Updated: March 2010

Page 204

Engineering Department Manual


E/A Design Division CAD Standard

M-VALVE_AUTO.dwg

(Varies)

Automatic Valve

M-VALVE_AUTO_3WAY.dwg

(Varies)

Three-Way Modulating Automatic Control Valve

M-VALVE_BALL.dwg

(Varies)

Balancing Valve

M-VALVE_BUTTERFLY.dwg

(Varies)

Butterfly Valve

M-VALVE_CHECK1.dwg

(Varies)

Check Valve Swing

M-VALVE_CHECK.dwg

(Varies)

Check Valve Lift

M-VALVE_DIAPHRAGM.dwg

(Varies)

Diaphragm Operated Control Valve Spring Opposed with Positioner

M-VALVE_GATE.dwg

(Varies)

Gate Valve

M-VALVE_GLOBE.dwg

(Varies)

Globe Valve

M-VALVE_LUBRICATION.dwg

(Varies)

Plug Valve

M-VALVE_MISC.dwg

(Varies)

EP Control Valve

M-VALVE_MOTORIZED.dwg

(Varies)

Motor-Operated Valve

M-VALVE_PRESSURE_RED.dwg

(Varies)

Pressure-Reducing Valve

Last Updated: March 2010

Page 205

Engineering Department Manual


E/A Design Division CAD Standard

M-VALVE_SOLONOID.dwg

(Varies)

Solenoid Valve

PRESSURE REDUCING VALVE.dwg

(Varies)

Pressure-Reducing Valve

RELIEF VALVE.dwg

(Varies)

Relief Valve

6.22.4.8
Symbol

PLUMBING & FIRE PROTECTION ACCESSORIES


Block Name P-ALARM_BELL.dwg Layer Name (Varies) Description Bell/Strobe

P-ALARM_HORN.dwg

(Varies)

Horn

P-AREA_DRAIN.dwg

(Varies)

Area Drain

P-BELL_STROBE.dwg

(Varies)

Bell Strobe

P-BWV.dwg

(Varies)

Back Water Valve

P-CLEANOUT.dwg

(Varies)

Cleanout

P-CLEANOUT_DECK_PLATE.dwg

(Varies)

Cleanout Deck Plate

P-CLEANOUT_ELEV.dwg

(Varies)

Cleanout (Elevation View)

P-CONNECTION TEE.dwg

(Varies)

Tee Connection

Last Updated: March 2010

Page 206

Engineering Department Manual


E/A Design Division CAD Standard

P-DOMCONT.dwg

(Varies)

Domestic Cont.

P-DRAIN_FLOOR.dwg

(Varies)

Floor Drain

P-DRAIN_FLOOR_RISER.dwg

(Varies)

Floor Drain Riser

P-DRAIN_FUNNEL.dwg

(Varies)

Funnel Drain

P-DRAIN_PTRAP_PRIMER.dwg

(Varies)

PTrap Drain Primer

P-DRAIN_ROOF_RISER.dwg

(Varies)

Drain Riser

P-DRAIN_STANDPIPE.dwg

(Varies)

Drain Standpipe

P-FA_INLET.dwg

(Varies)

Fresh Air Inlet

P-FA_INTAKE.dwg

(Varies)

Fresh Air Intake

P-FD.dwg

(Varies)

Floor Drain

P-FHC.dwg

(Varies)

Fire Hose Connection

P-FHC_PLAN.dwg

(Varies)

Fire Hose Connection (Plan)

P-FHR.dwg

(Varies)

Fire Hose Rack

Last Updated: March 2010

Page 207

Engineering Department Manual


E/A Design Division CAD Standard

P-FHR_PLAN.dwg

(Varies)

Fire Hose Rack (Plan)

P-FIRE_HOSE_CABINET_PLAN.dwg

(Varies)

Fire Hose & Cabinet

P-FIRE_HOSE_CABINET_ELEV.dwg

(Varies)

Fire Hose & Cabinet (Elevation)

P-FIRE_HOSE_RACK_ELEV.dwg

(Varies)

Fire Hose Rack (Elevation)

P-FIRE_HOSE_RACK_PLAN.dwg

(Varies)

Fire Hose Rack (Plan)

P-FLOOR_DRAIN.dwg

(Varies)

Drain Floor Pipe

P-FLOW_METER.dwg

(Varies)

Flow Meter

P-FLOW_SWITCH.dwg

(Varies)

Flow Switch

P-FLUSH_WALL_MOUNTED_SIAME.dwg

(Varies)

Wall-Mounted Siamese Connection

P-FREE_STANDING_SIAME.dwg

(Varies)

Free-Standing Siamese Connection

P-FRESH_AIR_INTAKE.dwg

(Varies)

Fresh Air Intake

P-FRESH_AIR_INTAKE_PLATE.dwg

(Varies)

Fresh Air Intake Plate

P-FUNDRAIN.dwg

(Varies)

Drain

Last Updated: March 2010

Page 208

Engineering Department Manual


E/A Design Division CAD Standard

P-GASBOOSTER.dwg

(Varies)

Gas Booster

P-GAUGE_PRESSURE.dwg

(Varies)

Pressure Gauge

P-GAUGE_THERMOMETER.dwg

(Varies)

Gauge Thermometer

P-GREASE_INTERCEPTOR.dwg

(Varies)

Grease Interceptor

P-GREASEINTCPT.dwg

(Varies)

Grease Interceptor

P-HB.dwg

(Varies)

Hose Bibb

P-HORN.dwg

(Varies)

Horn

P-HOSE_BIB.dwg

(Varies)

Hose Bibb

P-HTRAP.dwg

(Varies)

House Trap (Riser)

P-HVC.dwg

(Varies)

Hose Bibb Valve Connection

P-HWATERHEAT.dwg

(Varies)

Hot Water Heater (Riser)

P-MISCPMPRISE.dwg

(Varies)

Pump Riser (Miscellaneous)

P-PIPE_CAP.dwg

(Varies)

Pipe Cap

Last Updated: March 2010

Page 209

Engineering Department Manual


E/A Design Division CAD Standard

P-PIPE_TEE.dwg

(Varies)

Pipe Tee

P-PNEUTANK.dwg

(Varies)

Pneumatic Tank

P-PNEUTANKRISER.dwg

(Varies)

Pneumatic Tank (Riser)

P-PREHEATRISER.dwg

(Varies)

Pre-Heater (Riser)

P-RD.dwg

(Varies)

Roof Drain

P-ROOF_MANIFOLD.dwg

(Varies)

Roof Manifold

P-RPZ.dwg

(Varies)

RPZ (Riser)

P-SHOWER.dwg

(Varies)

Shower

P-SIAMESE_FREE_STANDING.dwg

(Varies)

Free-Standing Siamese

P-SIAMESE_WALL_MOUNTED.dwg

(Varies)

Flush Wall-Mounted Siamese

P-SINK.dwg

(Varies)

Sink

P-SLAV.dwg

(Varies)

Lavatory (Riser)

P-STANDDRAIN.dwg

(Varies)

Standpipe Drain

Last Updated: March 2010

Page 210

Engineering Department Manual


E/A Design Division CAD Standard

P-TANK_HOTWATER.dwg

(Varies)

Hot Water Storage Tank

P-TANK_PNEUMATIC.dwg

(Varies)

Pneumatic Tank

P-TANKFLOAT.dwg

(Varies)

Tank Float

P-THERMOMETER.dwg

(Varies)

Thermometer

P-THERMOSTAT.dwg

(Varies)

Thermostat

P-TR.dwg

(Varies)

Fixture P-Trap (Riser)

P-TRPPRM_DRN.dwg

(Varies)

Floor Drain Primer with P-Trap Connection

P-VACUUM_BREAKER.dwg

(Varies)

Vacuum Breaker

P-VACUUM_BREAKER_ASSEMBLY.dwg

(Varies)

Vacuum Breaker Assembly

P-VENTURBINPUMP.dwg

(Varies)

Turbine Pump

P-VFD.dwg

(Varies)

Variable Frequency Drive

P-VOR.dwg

(Varies)

Variable

P-VRV.dwg

(Varies)

Variable Valve

Last Updated: March 2010

Page 211

Engineering Department Manual


E/A Design Division CAD Standard 6.22.4.9
Symbol

PLUMBING & FIRE PROTECTION MECHANICAL EQUIPMENT


Block Name FP-AUTOFIREPUMP.dwg Layer Name (Varies) Description Automatic Fire Pump

FP-AUTOFPMPCTRL.dwg

(Varies)

Automatic Fire Pump Control

FP-FIRE_PUMP_CONTROL_PANEL.dwg

(Varies)

Automatic Fire Pump Control Panel

FP-FIRE_PUMP_JOCKEY.dwg

(Varies)

Jockey Pump Control Panel

FP-FIRE_PUMP_MAIN_PAD.dwg

(Varies)

Fire Pump Main Pad

FP-FIRE_PUMP_PANEL.dwg

(Varies)

Fire Pump Panel

FP-HORIZSPLTCASEPMP.dwg

(Varies)

Horizontal Split Case Pump

FP-JOCKEYPMP.dwg

(Varies)

Jockey Pump

FP-JOCKEYPMPCTRL-PA.dwg

(Varies)

Manual Fire Pump Control

FP-MANFIREPMP.dwg

(Varies)

Manual Fire Pump

FP-MANFIREPMPCONTROL.dwg

(Varies)

Manual Fire Pump Control

FP-MANUALFRPMP.dwg

(Varies)

Manual Fire Pump

Last Updated: March 2010

Page 212

Engineering Department Manual


E/A Design Division CAD Standard

FP-PUMP_FIRE.dwg

(Varies)

Fire Pump

FP-PUMP_HORIZONTAL.dwg

(Varies)

Horizontal Pump

FP-PUMP_JOCKEY.dwg

(Varies)

Jockey Pump (Plan)

P-DOMPUMP.dwg

(Varies)

Domestic Water Pump

P-FIRE_PUMP.dwg

(Varies)

Fire Pump

P-FIRE_PUMP_VERT.dwg

(Varies)

Fire Pump (Riser)

P-HWCIRCPMP.dwg

(Varies)

Hot Water Circulation Pump

P-PUMP.dwg

(Varies)

Pump (Plan)

P-PUMP_DOMESTIC.dwg

(Varies)

Domestic Pump

P-DUPLEX_EJECTOR_SUMP.dwg

(Varies)

Duplex Ejector/Sump Pump Discharge

P-PUMP_GAS_BOOSTER.dwg

(Varies)

Gas Booster Pump

P-PUMP_HW_CIRC.dwg

(Varies)

HW Circulation Pump (Riser)

P-PUMP_VERT_TURBINE.dwg

(Varies)

Vertical Turbine Pump (Riser)

Last Updated: March 2010

Page 213

Engineering Department Manual


E/A Design Division CAD Standard 6.22.4.10
Symbol

PLUMBING & FIRE PROTECTION MISCELLANEOUS


Block Name FP-HDETECT.dwg Layer Name (Varies) Description Heat Detector

MEC-CALLOUT.dwg

(Varies)

Callout for Plans

Mec-SEC-MARK.dwg

(Varies)

Section Mark

PA-BRK-PA.dwg

(Varies)

Break

P-ALARM_VALVE.dwg

(Varies)

Alarm Valve

P-B-671.dwg

(Varies)

Group Line Tag

P-BKFLWPREVENT.dwg

(Varies)

Backflow Preventer

P-BREAK_DUCT.dwg

(Varies)

Break Line

P-BREAK_DUCT_DOUBLE.dwg

(Varies)

Double Break Lines

P-BREAK_EQUIP.dwg

(Varies)

Break Line

P-BREAK_EQUIP_DOUBLE.dwg

(Varies)

Double Break Lines

P-BREAK_LINE2.dwg

(Varies)

Break Line Symbol for Double Linework

Last Updated: March 2010

Page 214

Engineering Department Manual


E/A Design Division CAD Standard

P-CEN.dwg

(Varies)

Point of Connection

P-CENLSYMB.dwg

(Varies)

Center Line Symbol

P-CENTER_LINE.dwg

(Varies)

Center Line Symbol

P-CUT2.dwg

(Varies)

Detail Symbol for Plans

P-CUT3.dwg

(Varies)

Section Head

P-CUT4.dwg

(Varies)

Section Line

P-CWBD.dwg

(Varies)

Cold Water

P-DELUGE_VALVE.dwg

(Varies)

Deluge Valve

P-DEN.dwg

(Varies)

Point of Disconnect

P-DRY_VALVE.dwg

(Varies)

Dry Valve

P-DUCT_BREAK.dwg

(Varies)

Duct Break

P-METER.dwg

(Varies)

Meter

P-MOTOR_OPERATED_VALVE.dwg

(Varies)

Motor-Operated Valve

Last Updated: March 2010

Page 215

Engineering Department Manual


E/A Design Division CAD Standard

P-NCV.dwg

(Varies)

Check Valve

P-NTAG.dwg

(Varies)

Tag

P-POINT_OF_CONNECTION.dwg

(Varies)

Connection Between Existing and New

P-POINT_OF_REMOVAL.dwg

(Varies)

Disconnection of Existing

P-PRE_ACTION_VALVE.dwg

(Varies)

Pre-Action Valve

P-PRESSURE_GAUGE.dwg

(Varies)

Pressure Gauge

P-PTAG.dwg

(Varies)

Plumbing Tag

P-PUMP_DISCHARGE.dwg

(Varies)

Pump Discharge

P-REM.dwg

(Varies)

Removal Marker

P-REMOVAL.dwg

(Varies)

Removal Marker

P-REV.dwg

(Varies)

Revision Tag

P-RISERBOX.dwg

(Varies)

Riser Box

P-SMOKE_DETECTOR_(DUCT).dwg

(Varies)

Duct Smoke Detector

Last Updated: March 2010

Page 216

Engineering Department Manual


E/A Design Division CAD Standard

P-SOLENOID_VALVE.dwg

(Varies)

Solenoid Valve

P-SPACE_THERMOSTAT_SENSOR.dwg

(Varies)

Space Thermostat Sensor

P-SPUMP.dwg

(Varies)

Supply Pump

P-SQF.dwg

(Varies)

Area Tag

P-SQUARE_FEET.dwg

(Varies)

Square Feet

P-SY.dwg

(Varies)

Plumbing Tag

P-SYM42.dwg

(Varies)

Tag

P-SYM43.dwg

(Varies)

Tag

P-SYM45.dwg

(Varies)

Tag

P-TAG.dwg

(Varies)

Plumbing Tag

P-TAG_CIRC1.dwg

(Varies)

Circle Tag

P-TAG_CIRC_2.dwg

(Varies)

Riser Tag

P-TAG_HEX.dwg

(Varies)

Hexagonal Tag

Last Updated: March 2010

Page 217

Engineering Department Manual


E/A Design Division CAD Standard

P-TAG_SQU.dwg

(Varies)

Square Tag

P-TAG_EQUIP.dwg

(Varies)

Equipment Tag

P-VR.dwg

(Varies)

Pressure-Reducing Valve

P-XTAG.dwg

(Varies)

Number Tag

6.22.4.11
Symbol

PLUMBING & FIRE PROTECTION PIPING


Block Name FP-WALLHYP.dwg Layer Name (Varies) Description Wall-Mounted Connection

P-2A.dwg

(Varies)

Double Cleanout

P-14A.dwg

(Varies)

Cleanout

P-CLEANOUT_RISER.dwg

(Varies)

Riser Cleanout

P-CLEANOUT_RISER_CONNECTION.dwg

(Varies)

Riser Cleanout Connection

P-LAVTRP.dwg

(Varies)

P-Trap

P-PIPE.dwg

(Varies)

Pipe Riser Symbol

P-PIPE_BREAK.dwg

(Varies)

Pipe Break Symbol

Last Updated: March 2010

Page 218

Engineering Department Manual


E/A Design Division CAD Standard

P-PIPE_BRK.dwg

(Varies)

Pipe Break Symbol

P-PIPE_CONN.dwg

(Varies)

Pipe Connection

P-PIPE_CONNECTION.dwg

(Varies)

New Pipe Connection

P-PIPE_DN.dwg

(Varies)

Elbow Down

P-PIPE_TEE_DN.dwg

(Varies)

Tee Down

P-PIPE_UP.dwg

(Varies)

Pipe Up

P-TEE_DN.dwg

(Varies)

Tee Down

P-UNDER.dwg

(Varies)

Sub-Surface Piping

6.22.4.12
Symbol

PLUMBING & FIRE PROTECTION SPRINKLERS


Block Name
P-PENDANT_SPRINKLER_ON_DROP_NIPPLE.dwg

Layer Name (Varies)

Description Pendant Sprinkler on Drop Nipple

P-SIDEWALL_SPRINKLER.dwg

(Varies)

Sidewall Sprinkler

P-SPKARR.dwg

(Varies)

Sprinkler

P-SPKR.dwg

(Varies)

Sprinkler

Last Updated: March 2010

Page 219

Engineering Department Manual


E/A Design Division CAD Standard

P-SPRINKLER_SIDEWALL.dwg

(Varies)

Sidewall Sprinkler

P-SPRINKLER_PENDANT.dwg

(Varies)

Pendant Sprinkler

P-SPRINKLER_RIG_ASSEMBLY.dwg

(Varies)

Sprinkler Rig Assembly

P-SPRINKLER_UPRIGHT.dwg

(Varies)

Upright Sprinkler

P-SPRINKLER_VALVE_FLOW.dwg

(Varies)

Sprinkler Control Valve with Flow Switch

P-UPRIGHT_SPRINKLER.dwg

(Varies)

Upright Sprinkler

6.22.4.13
Symbol

PLUMBING & FIRE PROTECTION VALVES


Block Name P-AUTOMATIC_VALVE.dwg Layer Name (Varies) Description Automatic Valve

P-BALL_VALVE.dwg

(Varies)

Ball Valve Symbol

P-BUTTERFLY_VALVE.dwg

(Varies)

Butterfly Valve

P-CHECK_VALVE.dwg

(Varies)

Check Valve

P-DOUBLECV.dwg

(Varies)

Double Check Valve

P-FIRE_HOSE_VALVE.dwg

(Varies)

Fire Hose Valve

Last Updated: March 2010

Page 220

Engineering Department Manual


E/A Design Division CAD Standard

P-GASVALVE.dwg

(Varies)

Gas Valve

P-GATE_VALVE.dwg

(Varies)

Gate Valve

P-GATE_VALVE_VERT.dwg

(Varies)

Gate Valve (Vertical)

P-GLOBE_VALVE.dwg

(Varies)

Globe Valve

P-HOLBYVALVE.dwg

(Varies)

Holby Valve

P-LUBRICATION_VALVE.dwg

(Varies)

Lubrication Valve

P-OSY.dwg

(Varies)

OS&Y Valve

P-PRV.dwg

(Varies)

PRV

P-PRV_RISER.dwg

(Varies)

PRV (Riser)

P-PRVSERIES_PARR.dwg

(Varies)

PRV Series

P-P-VALVE_OSY_VERTICAL.dwg

(Varies)

OS&Y Valve

P-RV.dwg

(Varies)

PRV

P-THREE_WAY_AUTO_VALVE.dwg

(Varies)

Three-Way Automatic Valve

Last Updated: March 2010

Page 221

Engineering Department Manual


E/A Design Division CAD Standard

P-VALVE_3_WAY_AUTO.dwg

(Varies)

3-Way Automatic Valve

P-VALVE_MIXING.dwg

(Varies)

Mixing Valve

P-VALVE_ALARM.dwg

(Varies)

Alarm Valve

P-VALVE_AUTOMATIC.dwg

(Varies)

Automatic Valve

P-VALVE_BACK_WATER.dwg

(Varies)

Back Water Valve

P-VALVE_BALL_DRIP.dwg

(Varies)

Check Valve with Automatic Ball Drip

P-VALVE_BUTTERFLY.dwg

(Varies)

Butterfly Valve

P-VALVE_CHECK.dwg

(Varies)

Check Valve

P-VALVE_DELUGE.dwg

(Varies)

Deluge Valve

P-VALVE_DOUBLE_GATE_CHECK.dwg

(Varies)

Double Gate & Check Valve Assembly Double Gate Valve with Double Check Valve Assembly

P-VALVE_DOUBLE_GATE_DOUBLE_CHECK.dwg

(Varies)

P-VALVE_DRY.dwg

(Varies)

Dry Valve

P-VALVE_FLOAT.dwg

(Varies)

Float Valve

Last Updated: March 2010

Page 222

Engineering Department Manual


E/A Design Division CAD Standard

P-VALVE_GAS_CONTROL.dwg

(Varies)

Gas Control Valve

P-VALVE_GATE_VERT.dwg

(Varies)

Gate Valve (Vertical)

P-VALVE_GATE.dwg

(Varies)

Gate Valve

P-VALVE_GATE_CHECK.dwg

(Varies)

Single Gate & Check Valve Assembly

P-VALVE_GLOBE.dwg

(Varies)

Globe Valve

P-VALVE_LUBRICATION.dwg

(Varies)

Lubrication Valve

P-VALVE_MOTORIZED.dwg

(Varies)

Motor-Operated Valve

P-VALVE_NORMALLY_CLOSED.dwg

(Varies)

Normally-Closed Valve

P-VALVE_OSY.dwg

(Varies)

OS & Y Valve

P-VALVE_PRE-ACTION.dwg

(Varies)

Pre-Action Valve

P-VALVE_PRESSURE_RELEASE.dwg

(Varies)

Pressure-Release Valve

P-VALVE_PRV.dwg

(Varies)

Pressure-Regulating Valve

P-VALVE_SOLENOID.dwg

(Varies)

Solenoid Valve

Last Updated: March 2010

Page 223

Engineering Department Manual


E/A Design Division CAD Standard

P-VALVE_VACUUM.dwg

(Varies)

Vacuum Breaker Assembly

Last Updated: March 2010

Page 224

Engineering Department Manual


E/A Design Division CAD Standard

6.23

APPENDIX G STRUCTURAL DISCIPLINE

6.23.1 CONTENT PREFERENCES This Section Is Currently Under Construction

Last Updated: March 2010

Page 225

Engineering Department Manual


E/A Design Division CAD Standard 6.23.2 LAYER STRATAGEM 6.23.2.1
Discipline

NEW WORK
Linetype

Phase

Minor

Major

Color

Plots

Desc

Description

ANNOTATION S S S S S S S S S S S S S S S S S S S S S S S S S ANNO ANNO ANNO ANNO ANNO ANNO ANNO ANNO ANNO ANNO ANNO ANNO ANNO ANNO AREA AREA AREA AREA BEAM BEAM BEAM BEAM BEAM BEAM BEAM HIDN TEXT STL_ STL_ CONC TMBR STFN DIMS KEYN KPLN TEXT NOTE NPLT RVSN SYMB SCHD TITL TTBL VPRT MLIN WELD PATT CLIM TEXT 71 71 9 3 3 7 4 71 141 211 7 8 30 71 9 220 3 9 212 3 212 223 4 13 191 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous PHANTOM2 Continuous Continuous Continuous Continuous BORDER2 HIDDEN2 Continuous Continuous Continuous Continuous Continuous Continuous Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No Yes Yes Yes Yes Yes Yes Yes No Yes Yes Yes Yes Yes Structural Dimensions Keynote / leader Insertion Layer Key plan Graphic Drafting/ Insertion Layer Structural Annotation (with Leaders) Structural Block Notes, General Notes, Legends etc.. Non-Plotting Layer Revision Tags and Clouds Block Insertion Layer Schedules, Tables Linework and AutoCAD Table Insertion Layer Drawing Titles (Block) Project Contract Border Insertion Layer Viewport (Mview) Creation Layer/ XCLIP Boundaries Match line Graphics Structural Welding Symbology Hatch Demarking Area Contract Limit Line Area Total/Calculations Text Boundary Area Line Structural Beam Obscured By Foreground Objects Text Relating To Beams (Sizes) Structural Steel Beams Structural Beam Stiffener Structural Concrete Beams, Including Precast Structural Timber Beams Structural Beams Structural Bracing Element Obscured By Foreground Element Structural Steel Bracing Structural Timber Bracing Miscellaneous Structural Bracing Structural Bracing Column Analysis (BIM)

AREA

BEAM

BRACE S S S S S S BRCE BRCE BRCE BRCE BRCE COLS ANLY HIDN STL_ WOOD MISC 62 212 15 62 190 7 HIDDEN2 Continuous Continuous Continuous Continuous Continuous Yes Yes Yes Yes Yes No

COLUMNS

Last Updated: March 2010

Page 226

Engineering Department Manual


E/A Design Division CAD Standard
S S S S S S S S S S S S S S S S S S S S COLS COLS COLS COLS COLS COLS COLS COLS DETL DETL DETL DETL DETL DETL DETL DETL DETL DETL DETL DETL HEVY FINE XFIN TEXT ABLT FRAM STL_ STL_ CONC TMBR MSRY MISC HIDN TEXT STL_ STL_ TMBR MSRY CONC BSPL 212 3 210 212 23 230 120 191 120 24 4 1 3 62 3 191 190 120 23 230 HIDDEN2 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Yes No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Structural Columns Obscured By Foreground Objects Text Relating To Column (Sizes) Structural Steel Column or Post Baseplate For Structural Steel Column Timber Column Masonry Column/Pier Concrete Column Structural Column Structural Detail Line (Medium Lineweight) Structural Detail Line (Thick Lineweight) Structural Detail Line (Thin Lineweight) Structural Detail Line (Very Thin Lineweight) Text Related to Structural Details Anchor Bolts, Clips and Fasteners Framing Members in Details Miscellaneous Steel Detail Linework (Medium Lineweight) Miscellaneous Steel Detail Linework (Thin Lineweight) Miscellaneous Concrete Detail Linework Miscellaneous Timber Detail Linework Miscellaneous Masonry Detail Linework, Clips, Anchors, Etc.. Text Associated With Equipment Appearing on Structural Plans, Details, Etc Equipment Appearing on Structural Plans, Details, Etc Schematic Plans - Major Floor Framing Elements Schematic Plans - Minor Floor Framing Elements, Bridging Schematic Plans - Span Direction Symbology Insertion Layer Floor Framing Elements Obscured By Foreground Objects Stairs Framing Elements, Stringers, Landing Framing Members, Etc... Stairs Framing Components Obscured By Foreground Objects Floor/ Slab Edge, Openings and Depressions Floor/ Slab Above Floor/ Slab Below Metal Decking Floor Materials Cut Outline Structural Foundation Footings (Medium Detail) Structural Footings Below Footing Elements Obscured By Foreground Objects

DETAIL

EQUIPMENT S S S S S S S S S S S S S S S S EQPM EQPM FRAM FRAM FRAM FRAM FRAM FRAM FLOR FLOR FLOR FLOR FLOR FTNG FTNG FTNG BLOW HIDN ABVE BLOW DECK MCUT MAJR MINR SPAN HIDN STRS STRS HIDN TEXT 3 81 191 190 71 212 190 190 3 1 1 150 192 131 140 1 Continuous Continuous Continuous Continuous Continuous HIDDEN Continuous HIDDEN2 Continuous DASHED2 Continuous Continuous Continuous Continuous Continuous HIDDEN2 Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

FRAMING

FLOOR/SLAB

FOOTING

HATCH PATTERNS

Last Updated: March 2010

Page 227

Engineering Department Manual


E/A Design Division CAD Standard
S S S S S S S S GRID S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S GRID GRID GRID JOIS JOIS LOAD LOAD LOAD LOAD LOAD LOAD LOAD LOAD LOAD LOAD LOAD MASS MASS MASS PAVM PAVM PAVM PAVM PAVM PAVM PILE PILE PILE PILE RBAR HIDN STL_ TMBR ASPH CONC SCLN PATT HIDN ABVE LINE AREA CALC DEAD LIVE POIN ROOF SEIS SNOW TEMP WIND TEXT HIDN MINR SYMB 223 8 212 190 9 8 8 8 8 8 8 8 8 8 8 8 3 71 80 52 50 131 54 2 2 212 210 23 191 201 CENTER CENTER2 Continuous Continuous DASHED2 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous HIDDEN2 Continuous Continuous Continuous Continuous Continuous HIDDEN2 Continuous HIDDEN2 Continuous Continuous Continuous Continuous Yes Yes Yes Yes Yes No No No No No No No No No No No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Structural Grid Structural Grid - Minor or Partial Grids Column Identification Bubbles Structural Joists Structural Joists Above Line Loads (BIM) Non-Plotting Area Loads (BIM) Non-Plotting Load Calculations Non-Plotting Dead Loads (BIM) Non-Plotting Live Loads (BIM) Non-Plotting Point Loads (BIM) Non-Plotting Roof Loads (BIM) Non-Plotting Seismic Loads (BIM) Non-Plotting Snow Loads (BIM) Non-Plotting Temperature Loads (BIM) Non-Plotting Wind Loads (BIM) Non-Plotting Text Associated With Mass Objects Mass Elements Obscured by Foreground Elements Mass Elements Asphalt Pavement Concrete Pavement Scorelines, Cut Lines, Expansion Joints of Paved Areas Hatched Area Denoting Paved Area, Traffic Patterns, Etc.. Elements Within Paving That Are Obscured From View Pavement General Piles Obscured By Foreground Objects Structural Steel Piles Timber Piles Structural Piles Structural Steel Reinforcing Bar PATT PATT PATT PATT PATT PATT PATT PATT STL_ CONC TMBR MSRY SCLN FILL GRVL 223 223 223 223 131 252 252 9 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Yes Yes Yes Yes Yes Yes Yes Yes Steel Hatch Patterns Concrete/Mortar Fill Hatch Patterns Wood Grain Patterns Masonry Hatch Patterns Scorelines, Cut Lines, Expansion Joints, Etc.. Earth Fill Hatch Patterns Gravel Fill Hatch Patterns Hatch Patterns

JOIST

LOAD

MODELING/MASSING

PAVEMENT

PILES

REBAR

Last Updated: March 2010

Page 228

Engineering Department Manual


E/A Design Division CAD Standard
S S S S S S S S S S S S S S S S S S S S S RBAR RENF RENF REFN ROOF ROOF ROOF ROOF ROOF ROOF TRUS TRUS WALL WALL WALL WALL WALL WALL WALL XREF XREF RAST ABVE HIDN SHEA RETN PATT MSRY CONC DECK OTLN PATT ABVE BLOW TIES HIDN WMSH 9 201 212 6 150 140 223 1 1 3 212 9 4 4 50 8 23 4 120 7 7 Continuous HIDDEN2 WWF Continuous Continuous Continuous Continuous DASHED2 Continuous Continuous Continuous DASHED2 HIDDEN2 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Structural Steel Reinforcing Ties, Bridging, Stirrups, Etc.. Miscellaneous Reinforcing Elements Welded Wire Fabric Mesh Reinforcing Elements Metal Roof Decking Outline of Roof, Openings and Changes in Elevation Hatch Patterns On Roofing Plans and Details Roof Elements Above Roof Elements Below Structural Roof Elements Trusses and Space Frames Trusses and Space Frames Above Wall Element Obscured By Foreground Element Structural Shear Walls Retaining Walls Hatch Patterns In Wall Elements Masonry Wall Linework, Brick/Block Coursing, ETC Structural Concrete Walls Structural Walls External Reference Attachment Layer Image Reference Attachment Layer

REINFORCMENT

ROOF

TRUSS

WALL

XREF

6.23.2.2
Discipline

EXISTING WORK
Linetype

Phase

Minor

Major

Color

Plots

Desc

Description

Default Existing Layer Properties (Unless Otherwise Noted Below) S EXST ____ ____ ____ Continuous Yes ANNOTATION S S S S S ANNO ANNO AREA AREA AREA DIMS TEXT PATT TEXT ____ ____ ____ ____ ____ EXST EXST EXST EXST EXST 71 3 252 3 252 Continuous Continuous Continuous Continuous BORDER2 Yes Yes Yes Yes Yes Existing Structural Dimensions Existing Structural Annotation (with Leaders) Existing Hatch Demarking Area Existing Area Total/Calculations Text Existing Boundary Area Line Existing Structural Beam Obscured By Foreground Objects

AREA

BEAM S BEAM HIDN ____ EXST 200 HIDDEN2 Yes

Last Updated: March 2010

Page 229

Engineering Department Manual


E/A Design Division CAD Standard
S S S S S S BEAM BEAM BEAM BEAM BEAM BEAM TEXT STL_ STL_ CONC TMBR ____ ____ STFN ____ ____ ____ EXST EXST EXST EXST EXST EXST 3 252 252 252 252 200 Continuous Continuous Continuous Continuous Continuous Continuous No Yes Yes Yes Yes Yes Existing Text Relating To Beams (Sizes) Existing Structural Steel Beams Existing Structural Beam Stiffener Existing Structural Concrete Beams, Including Precast Existing Structural Timber Beams Existing Structural Beams Existing Structural Bracing Element Obscured By Foreground Element Existing Structural Steel Bracing Existing Structural Timber Bracing Existing Miscellaneous Structural Bracing Existing Structural Bracing Existing Column Analysis (BIM) Existing Structural Columns Obscured By Foreground Objects Existing Text Relating To Column (Sizes) Existing Structural Steel Column or Post Existing Baseplate For Structural Steel Column Existing Timber Column Existing Masonry Column/Pier Existing Concrete Column Existing Structural Column Existing Structural Detail Line (Medium Lineweight) Existing Structural Detail Line (Thick Lineweight) Existing Structural Detail Line (Thin Lineweight) Existing Structural Detail Line (Very Thin Lineweight) Existing Text Related to Structural Details Existing Anchor Bolts, Clips and Fasteners Existing Framing Members in Details Existing Miscellaneous Steel Detail Linework (Medium Lineweight) Existing Miscellaneous Steel Detail Linework (Thin Lineweight) Existing Miscellaneous Concrete Detail Linework Existing Miscellaneous Timber Detail Linework Existing Miscellaneous Masonry Detail Linework, Clips, Anchors, Etc.. Existing Text Associated With Equipment Appearing on Structural Plans, Details, Etc Existing Equipment Appearing on Structural Plans, Details, Etc Existing Schematic Plans - Major Floor Framing Elements Existing Schematic Plans - Minor Floor Framing Elements, Bridging

BRACE S S S S S S S S S S S S S S S S S S S S S S S S S S BRCE BRCE BRCE BRCE BRCE COLS COLS COLS COLS COLS COLS COLS COLS COLS DETL DETL DETL DETL DETL DETL DETL DETL DETL DETL DETL DETL HEVY FINE XFIN TEXT ABLT FRAM STL_ STL_ CONC TMBR MSRY ANLY HIDN TEXT STL_ STL_ TMBR MSRY CONC HIDN STL_ WOOD MISC ____ ____ ____ ____ ____ ____ ____ ____ ____ BSPL ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ MISC ____ ____ ____ EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST 200 252 252 252 200 252 200 3 252 252 252 252 252 200 252 252 252 252 3 252 252 200 252 240 223 240 HIDDEN2 Continuous Continuous Continuous Continuous Continuous HIDDEN2 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Yes Yes Yes Yes Yes No Yes No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

COLUMNS

DETAIL

EQUIPMENT S S S S EQPM EQPM FRAM FRAM MAJR MINR TEXT ____ ____ ____ ____ EXST EXST EXST EXST 3 252 252 252 Continuous Continuous Continuous Continuous Yes Yes Yes Yes

FRAMING

Last Updated: March 2010

Page 230

Engineering Department Manual


E/A Design Division CAD Standard
Existing Schematic Plans - Span Direction Symbology Insertion Layer Existing Floor Framing Elements Obscured By Foreground Objects Existing Stairs Framing Elements, Stringers, Landing Framing Members, Etc... Existing Stairs Framing Components Obscured By Foreground Objects Existing Floor/ Slab Edge, Openings and Depressions Existing Floor/ Slab Above Existing Floor/ Slab Below Existing Metal Decking Existing Floor Materials Cut Outline Existing Structural Foundation Footings (Medium Detail) Existing Structural Footings Below Existing Footing Elements Obscured By Foreground Objects Existing Steel Hatch Patterns Existing Concrete/Mortar Fill Hatch Patterns Existing Wood Grain Patterns Existing Masonry Hatch Patterns Existing Scorelines, Cut Lines, Expansion Joints, Etc.. Existing Earth Fill Hatch Patterns Existing Gravel Fill Hatch Patterns Existing Hatch Patterns Existing Structural Grid Existing Structural Grid - Minor or Partial Grids Existing Column Identification Bubbles Existing Structural Joists Existing Structural Joists Above Existing Line Loads (BIM) Non-Plotting Existing Area Loads (BIM) Non-Plotting Existing Load Calculations Non-Plotting Existing Dead Loads (BIM) Non-Plotting Existing Live Loads (BIM) Non-Plotting Existing Point Loads (BIM) Non-Plotting Existing Roof Loads (BIM) Non-Plotting Existing Seismic Loads (BIM) Non-Plotting Existing Snow Loads (BIM) Non-Plotting Existing Temperature Loads (BIM) Non-Plotting Existing Wind Loads (BIM) Non-Plotting

S S S S S S S S S S S S S S S S S S S S GRID S S S S S S S S S S S S S S S S

FRAM FRAM FRAM FRAM FLOR FLOR FLOR FLOR FLOR FTNG FTNG FTNG PATT PATT PATT PATT PATT PATT PATT PATT GRID GRID GRID JOIS JOIS LOAD LOAD LOAD LOAD LOAD LOAD LOAD LOAD LOAD LOAD LOAD

SPAN HIDN STRS STRS

____ ____ ____ HIDN ____

EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST

252 252 252 252 9 8 8 252 252 110 252 110 8 8 252 252 252 252 252 8 140 8 252 8 8 252 252 252 252 252 252 252 252 252 252 252

Continuous HIDDEN Continuous HIDDEN2 Continuous DASHED2 Continuous Continuous Continuous Continuous Continuous HIDDEN2 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous CENTER CENTER2 Continuous Continuous DASHED2 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous

Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No No No No No No No No No No No

FLOOR/SLAB ABVE BLOW DECK MCUT ____ ____ ____ ____ ____ BLOW HIDN STL_ CONC TMBR MSRY SCLN FILL GRVL ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ MINR SYMB ____ ____ ____ ABVE LINE AREA CALC DEAD LIVE POIN ROOF SEIS SNOW TEMP WIND ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____

FOOTING

HATCH PATTERNS

JOIST

LOAD

MODELING/MASSING

Last Updated: March 2010

Page 231

Engineering Department Manual


E/A Design Division CAD Standard
S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S MASS MASS MASS PAVM PAVM PAVM PAVM PAVM PAVM PILE PILE PILE PILE RBAR RBAR RENF RENF REFN ROOF ROOF ROOF ROOF ROOF ROOF TRUS TRUS WALL WALL WALL WALL WALL WALL WALL ABVE HIDN SHEA RETN PATT MSRY CONC DECK OTLN PATT ABVE BLOW TIES HIDN WMSH HIDN STL_ TMBR ASPH CONC SCLN PATT HIDN TEXT HIDN ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST 3 252 252 8 8 252 252 54 54 252 252 252 252 252 252 240 252 240 252 252 252 8 8 9 8 8 140 252 252 252 252 140 110 Continuous HIDDEN2 Continuous Continuous Continuous Continuous Continuous HIDDEN2 Continuous HIDDEN2 Continuous Continuous Continuous Continuous Continuous HIDDEN2 WWF Continuous Continuous Continuous Continuous DASHED2 Continuous Continuous Continuous DASHED2 HIDDEN2 Continuous Continuous Continuous Continuous Continuous Continuous Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Existing Text Associated With Mass Objects Existing Mass Elements Obscured by Foreground Elements Existing Mass Elements Existing Asphalt Pavement Existing Concrete Pavement Existing Scorelines, Cut Lines, Expansion Joints of Paved Areas Existing Hatched Area Denoting Paved Area, Traffic Patterns, Etc.. Existing Elements Within Paving That Are Obscured From View Existing Pavement General Existing Piles Obscured By Foreground Objects Existing Structural Steel Piles Existing Timber Piles Existing Structural Piles Existing Structural Steel Reinforcing Bar Existing Structural Steel Reinforcing Ties, Bridging, Stirrups, Etc.. Existing Miscellaneous Reinforcing Elements Existing Welded Wire Fabric Mesh Existing Reinforcing Elements Existing Metal Roof Decking Existing Outline of Roof, Openings and Changes in Elevation Existing Hatch Patterns On Roofing Plans and Details Existing Roof Elements Above Existing Roof Elements Below Existing Structural Roof Elements Existing Trusses and Space Frames Existing Trusses and Space Frames Above Existing Wall Element Obscured By Foreground Element Existing Structural Shear Walls Existing Retaining Walls Existing Hatch Patterns In Wall Elements Existing Masonry Wall Linework, Brick/Block Coursing, ETC Existing Structural Concrete Walls Existing Structural Walls

PAVEMENT

PILES

REBAR

REINFORCMENT

ROOF

TRUSS

WALL

Last Updated: March 2010

Page 232

Engineering Department Manual


E/A Design Division CAD Standard 6.23.2.3
Discipline

FUTURE WORK
Linetype

Phase

Minor

Major

Color

Plots

Desc

Description

Default Future Layer Properties (Unless Otherwise Noted Below) S FUTR ____ ____ ____ Continuous Yes ANNOTATION S S S S S S S S S S S S ANNO ANNO AREA AREA AREA BEAM BEAM BEAM BEAM BEAM BEAM BEAM HIDN TEXT STL_ STL_ CONC TMBR DIMS TEXT PATT TEXT ____ ____ ____ ____ ____ ____ ____ ____ STFN ____ ____ ____ FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR 5 3 5 3 5 5 3 5 5 5 5 5 Continuous Continuous Continuous Continuous BORDER2 HIDDEN2 Continuous Continuous Continuous Continuous Continuous Continuous Yes Yes Yes Yes Yes Yes No Yes Yes Yes Yes Yes Future Structural Dimensions Future Structural Annotation (with Leaders) Future Hatch Demarking Area Future Area Total/Calculations Text Future Boundary Area Line Future Structural Beam Obscured By Foreground Objects Future Text Relating To Beams (Sizes) Future Structural Steel Beams Future Structural Beam Stiffener Future Structural Concrete Beams, Including Precast Future Structural Timber Beams Future Structural Beams Future Structural Bracing Element Obscured By Foreground Element Future Structural Steel Bracing Future Structural Timber Bracing Future Miscellaneous Structural Bracing Future Structural Bracing Future Column Analysis (BIM) Future Structural Columns Obscured By Foreground Objects Future Text Relating To Column (Sizes) Future Structural Steel Column or Post Future Baseplate For Structural Steel Column Future Timber Column Future Masonry Column/Pier Future Concrete Column Future Structural Column Future Structural Detail Line (Medium Lineweight) Future Structural Detail Line (Thick Lineweight) Future Structural Detail Line (Thin Lineweight) Future Structural Detail Line (Very Thin Lineweight)

AREA

BEAM

BRACE S S S S S S S S S S S S S S S S S S BRCE BRCE BRCE BRCE BRCE COLS COLS COLS COLS COLS COLS COLS COLS COLS DETL DETL DETL DETL HEVY FINE XFIN ANLY HIDN TEXT STL_ STL_ TMBR MSRY CONC HIDN STL_ WOOD MISC ____ ____ ____ ____ ____ ____ ____ ____ ____ BSPL ____ ____ ____ ____ ____ ____ ____ ____ FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR 5 5 5 5 5 5 5 3 5 5 5 5 5 5 5 5 5 5 HIDDEN2 Continuous Continuous Continuous Continuous Continuous HIDDEN2 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Yes Yes Yes Yes Yes No Yes No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

COLUMNS

DETAIL

Last Updated: March 2010

Page 233

Engineering Department Manual


E/A Design Division CAD Standard
S S S S S S S S DETL DETL DETL DETL DETL DETL DETL DETL TEXT ABLT FRAM STL_ STL_ CONC TMBR MSRY ____ ____ ____ ____ MISC ____ ____ ____ FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR 3 5 5 5 5 5 5 5 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Yes Yes Yes Yes Yes Yes Yes Yes Future Text Related to Structural Details Future Anchor Bolts, Clips and Fasteners Future Framing Members in Details Future Miscellaneous Steel Detail Linework (Medium Lineweight) Future Miscellaneous Steel Detail Linework (Thin Lineweight) Future Miscellaneous Concrete Detail Linework Future Miscellaneous Timber Detail Linework Future Miscellaneous Masonry Detail Linework, Clips, Anchors, Etc.. Future Text Associated With Equipment Appearing on Structural Plans, Details, Etc Future Equipment Appearing on Structural Plans, Details, Etc Future Schematic Plans - Major Floor Framing Elements Future Schematic Plans - Minor Floor Framing Elements, Bridging Future Schematic Plans - Span Direction Symbology Insertion Layer Future Floor Framing Elements Obscured By Foreground Objects Future Stairs Framing Elements, Stringers, Landing Framing Members, Etc... Future Stairs Framing Components Obscured By Foreground Objects Future Floor/ Slab Edge, Openings and Depressions Future Floor/ Slab Above Future Floor/ Slab Below Future Metal Decking Future Floor Materials Cut Outline Future Structural Foundation Footings (Medium Detail) Future Structural Footings Below Future Footing Elements Obscured By Foreground Objects Future Steel Hatch Patterns Future Concrete/Mortar Fill Hatch Patterns Future Wood Grain Patterns Future Masonry Hatch Patterns Future Scorelines, Cut Lines, Expansion Joints, Etc.. Future Earth Fill Hatch Patterns Future Gravel Fill Hatch Patterns Future Hatch Patterns Future Structural Grid Future Structural Grid - Minor or Partial Grids

EQUIPMENT S S S S S S S S S S S S S S S S S S S S S S S S GRID S S GRID GRID MINR ____ ____ FUTR FUTR 5 5 CENTER CENTER2 Yes Yes EQPM EQPM FRAM FRAM FRAM FRAM FRAM FRAM FLOR FLOR FLOR FLOR FLOR FTNG FTNG FTNG PATT PATT PATT PATT PATT PATT PATT PATT BLOW HIDN STL_ CONC TMBR MSRY SCLN FILL GRVL ABVE BLOW DECK MCUT MAJR MINR SPAN HIDN STRS STRS TEXT ____ ____ ____ ____ ____ ____ ____ HIDN ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR 3 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Continuous Continuous Continuous Continuous Continuous HIDDEN Continuous HIDDEN2 Continuous DASHED2 Continuous Continuous Continuous Continuous Continuous HIDDEN2 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

FRAMING

FLOOR/SLAB

FOOTING

HATCH PATTERNS

Last Updated: March 2010

Page 234

Engineering Department Manual


E/A Design Division CAD Standard
S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S GRID JOIS JOIS LOAD LOAD LOAD LOAD LOAD LOAD LOAD LOAD LOAD LOAD LOAD MASS MASS MASS PAVM PAVM PAVM PAVM PAVM PAVM PILE PILE PILE PILE RBAR RBAR RENF RENF REFN ROOF ROOF DECK OTLN TIES HIDN WMSH HIDN STL_ TMBR ASPH CONC SCLN PATT HIDN ABVE LINE AREA CALC DEAD LIVE POIN ROOF SEIS SNOW TEMP WIND TEXT HIDN SYMB ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR 5 5 5 5 5 5 5 5 5 5 5 5 5 5 3 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Continuous Continuous DASHED2 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous HIDDEN2 Continuous Continuous Continuous Continuous Continuous HIDDEN2 Continuous HIDDEN2 Continuous Continuous Continuous Continuous Continuous HIDDEN2 WWF Continuous Continuous Continuous Yes Yes Yes No No No No No No No No No No No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Future Column Identification Bubbles Future Structural Joists Future Structural Joists Above Future Line Loads (BIM) Non-Plotting Future Area Loads (BIM) Non-Plotting Future Load Calculations Non-Plotting Future Dead Loads (BIM) Non-Plotting Future Live Loads (BIM) Non-Plotting Future Point Loads (BIM) Non-Plotting Future Roof Loads (BIM) Non-Plotting Future Seismic Loads (BIM) Non-Plotting Future Snow Loads (BIM) Non-Plotting Future Temperature Loads (BIM) Non-Plotting Future Wind Loads (BIM) Non-Plotting Future Text Associated With Mass Objects Future Mass Elements Obscured by Foreground Elements Future Mass Elements Future Asphalt Pavement Future Concrete Pavement Future Scorelines, Cut Lines, Expansion Joints of Paved Areas Future Hatched Area Denoting Paved Area, Traffic Patterns, Etc.. Future Elements Within Paving That Are Obscured From View Future Pavement General Future Piles Obscured By Foreground Objects Future Structural Steel Piles Future Timber Piles Future Structural Piles Future Structural Steel Reinforcing Bar Future Structural Steel Reinforcing Ties, Bridging, Stirrups, Etc.. Future Miscellaneous Reinforcing Elements Future Welded Wire Fabric Mesh Future Reinforcing Elements Future Metal Roof Decking Future Outline of Roof, Openings and Changes in Elevation

JOIST

LOAD

MODELING/MASSING

PAVEMENT

PILES

REBAR

REINFORCMENT

ROOF

Last Updated: March 2010

Page 235

Engineering Department Manual


E/A Design Division CAD Standard
S S S S S S S S S S S S S ROOF ROOF ROOF ROOF TRUS TRUS WALL WALL WALL WALL WALL WALL WALL ABVE HIDN SHEA RETN PATT MSRY CONC PATT ABVE BLOW ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR FUTR 5 5 5 5 5 5 5 5 5 5 5 5 5 Continuous DASHED2 Continuous Continuous Continuous DASHED2 HIDDEN2 Continuous Continuous Continuous Continuous Continuous Continuous Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Future Hatch Patterns On Roofing Plans and Details Future Roof Elements Above Future Roof Elements Below Future Structural Roof Elements Future Trusses and Space Frames Future Trusses and Space Frames Above Future Wall Element Obscured By Foreground Element Future Structural Shear Walls Future Retaining Walls Future Hatch Patterns In Wall Elements Future Masonry Wall Linework, Brick/Block Coursing, ETC Future Structural Concrete Walls Future Structural Walls

TRUSS

WALL

6.23.2.4
Discipline

RELOCATED WORK
Linetype

Phase

Minor

Major

Color

Plots

Desc

Description

Default Relocated Layer Properties (Unless Otherwise Noted Below) S RELO ____ ____ ____ 1 Continuous Yes ANNOTATION S S S S S ANNO AREA BEAM COLS DETL TEXT TEXT TEXT TEXT TEXT ____ ____ ____ ____ ____ RELO RELO RELO RELO RELO 3 3 3 3 3 Continuous Continuous Continuous Continuous Continuous Yes Yes No No Yes Relocated Structural Annotation (with Leaders) Relocated Area Total/Calculations Text Relocated Text Relating To Beams (Sizes) Relocated Text Relating To Column (Sizes) Relocated Text Related to Structural Details Relocated Text Associated With Equipment Appearing on Structural Plans, Details, Etc Relocated Structural Grid Relocated Structural Grid - Minor or Partial Grids Relocated Structural Joists Above Relocated Text Associated With Mass Objects Relocated Mass Elements Obscured by Foreground Elements AREA BEAM COLUMNS DETAIL EQUIPMENT S GRID S S S S S GRID GRID JOIS MASS MASS MINR ABVE TEXT HIDN ____ ____ ____ ____ ____ RELO RELO RELO RELO RELO 1 1 1 3 1 CENTER CENTER2 DASHED2 Continuous HIDDEN2 Yes Yes Yes Yes Yes EQPM TEXT ____ RELO 3 Continuous Yes

JOIST MODELING/MASSING

Last Updated: March 2010

Page 236

Engineering Department Manual


E/A Design Division CAD Standard
PAVEMENT S S S S S S PAVM PILE RENF RENF ROOF TRUS HIDN HIDN HIDN WMSH ABVE ABVE ____ ____ ____ ____ ____ ____ RELO RELO RELO RELO RELO RELO 1 1 1 1 1 1 HIDDEN2 HIDDEN2 HIDDEN2 WWF DASHED2 DASHED2 Yes Yes Yes Yes Yes Yes Relocated Elements Within Paving That Are Obscured From View Relocated Piles Obscured By Foreground Objects Relocated Miscellaneous Reinforcing Elements Relocated Welded Wire Fabric Mesh Relocated Roof Elements Above Relocated Trusses and Space Frames Above Relocated Wall Element Obscured By Foreground Element

PILES REINFORCMENT

ROOF TRUSS WALL S WALL HIDN ____ RELO 1 HIDDEN2 Yes

6.23.2.5
Discipline

REMOVAL WORK
Linetype

Phase

Minor

Major

Color

Plots

Desc

Description

Default Removal Layer Properties (Unless Otherwise Noted Below) S RMVL ____ ____ ____ 15 Continuous Yes ANNOTATION S S S ANNO AREA AREA TEXT TEXT ____ ____ ____ RMVL RMVL RMVL 3 3 15 Continuous Continuous BORDER2 Yes Yes Yes Removal Of Structural Annotation (with Leaders) Removal Of Area Total/Calculations Text Removal Of Boundary Area Line Removal Of Structural Beam Obscured By Foreground Objects Removal Of Structural Bracing Element Obscured By Foreground Element Removal Of Structural Columns Obscured By Foreground Objects Removal Of Text Related to Structural Details Removal Of Text Associated With Equipment Appearing on Structural Plans, Details, Etc Removal Of Floor Framing Elements Obscured By Foreground Objects Removal Of Stairs Framing Components Obscured By Foreground Objects AREA

BEAM S BEAM HIDN ____ RMVL 15 HIDDEN2 Yes

BRACE S BRCE HIDN ____ RMVL 15 HIDDEN2 Yes

COLUMNS S S COLS DETL HIDN TEXT ____ ____ RMVL RMVL 15 3 HIDDEN2 Continuous Yes Yes

DETAIL EQUIPMENT S EQPM TEXT ____ RMVL 3 Continuous Yes

FRAMING S S FRAM FRAM HIDN STRS ____ HIDN RMVL RMVL 15 15 HIDDEN HIDDEN2 Yes Yes

FLOOR/SLAB

Last Updated: March 2010

Page 237

Engineering Department Manual


E/A Design Division CAD Standard
S FLOR ABVE ____ RMVL 15 DASHED2 Yes Removal Of Floor/ Slab Above Removal Of Footing Elements Obscured By Foreground Objects Removal Of Structural Grid Removal Of Structural Grid - Minor or Partial Grids Removal Of Structural Joists Above Removal Of Text Associated With Mass Objects Removal Of Mass Elements Obscured by Foreground Elements Removal Of Elements Within Paving That Are Obscured From View Removal Of Piles Obscured By Foreground Objects Removal Of Miscellaneous Reinforcing Elements Removal Of Welded Wire Fabric Mesh Removal Of Roof Elements Above Removal Of Trusses and Space Frames Above Removal Of Wall Element Obscured By Foreground Element

FOOTING S GRID S S S S S GRID GRID JOIS MASS MASS MINR ABVE TEXT HIDN ____ ____ ____ ____ ____ RMVL RMVL RMVL RMVL RMVL 15 15 15 3 15 CENTER CENTER2 DASHED2 Continuous HIDDEN2 Yes Yes Yes Yes Yes FTNG HIDN ____ RMVL 15 HIDDEN2 Yes

JOIST MODELING/MASSING

PAVEMENT S S S S S S PAVM PILE RENF RENF ROOF TRUS HIDN HIDN HIDN WMSH ABVE ABVE ____ ____ ____ ____ ____ ____ RMVL RMVL RMVL RMVL RMVL RMVL 15 15 15 15 15 15 HIDDEN2 HIDDEN2 HIDDEN2 WWF DASHED2 DASHED2 Yes Yes Yes Yes Yes Yes

PILES REINFORCMENT

ROOF TRUSS WALL S WALL HIDN ____ RMVL 15 HIDDEN2 Yes

6.23.2.6
Discipline

TEMPORARY WORK
Linetype

Phase

Minor

Major

Color

Plots

Desc

Description

Default Temporary Layer Properties (Unless Otherwise Noted Below) S TEMP ____ ____ ____ 46 Continuous Yes ANNOTATION S S S S S ANNO AREA AREA BEAM BEAM HIDN TEXT TEXT TEXT ____ ____ ____ ____ ____ TEMP TEMP TEMP TEMP TEMP 3 3 46 46 3 Continuous Continuous BORDER2 HIDDEN2 Continuous Yes Yes Yes Yes No Temporary Structural Annotation (with Leaders) Temporary Area Total/Calculations Text Temporary Boundary Area Line Temporary Structural Beam Obscured By Foreground Temporary Text Relating To Beams (Sizes) Temporary Structural Bracing Element Obscured By Foreground Element AREA

BEAM

BRACE S BRCE HIDN ____ TEMP 46 HIDDEN2 Yes

Last Updated: March 2010

Page 238

Engineering Department Manual


E/A Design Division CAD Standard
COLUMNS S S S COLS COLS DETL HIDN TEXT TEXT ____ ____ ____ TEMP TEMP TEMP 46 3 3 HIDDEN2 Continuous Continuous Yes No Yes Temporary Structural Columns Obscured By Foreground Temporary Text Relating To Column (Sizes) Temporary Text Related to Structural Details Temporary Text Associated With Equipment Appearing on Structural Plans, Details, Etc Temporary Floor Framing Elements Obscured By Foreground Objects Temporary Stairs Framing Components Obscured By Foreground Objects Temporary Floor/ Slab Above Temporary Footing Elements Obscured By Foreground Objects Temporary Structural Grid Temporary Structural Grid - Minor or Partial Grids Temporary Structural Joists Above Temporary Text Associated With Mass Objects Temporary Mass Elements Obscured by Foreground Elements Temporary Elements Within Paving That Are Obscured From View Temporary Piles Obscured By Foreground Objects Temporary Miscellaneous Reinforcing Elements Temporary Welded Wire Fabric Mesh Temporary Roof Elements Above Temporary Trusses and Space Frames Above Temporary Wall Element Obscured By Foreground Element

DETAIL EQUIPMENT S EQPM TEXT ____ TEMP 3 Continuous Yes

FRAMING S S S FRAM FRAM FLOR HIDN STRS ABVE ____ HIDN ____ TEMP TEMP TEMP 46 46 46 HIDDEN HIDDEN2 DASHED2 Yes Yes Yes

FLOOR/SLAB FOOTING S GRID S S S S S GRID GRID JOIS MASS MASS MINR ABVE TEXT HIDN ____ ____ ____ ____ ____ TEMP TEMP TEMP TEMP TEMP 46 46 46 3 46 CENTER CENTER2 DASHED2 Continuous HIDDEN2 Yes Yes Yes Yes Yes FTNG HIDN ____ TEMP 46 HIDDEN2 Yes

JOIST MODELING/MASSING

PAVEMENT S S S S S S PAVM PILE RENF RENF ROOF TRUS HIDN HIDN HIDN WMSH ABVE ABVE ____ ____ ____ ____ ____ ____ TEMP TEMP TEMP TEMP TEMP TEMP 46 46 46 46 46 46 HIDDEN2 HIDDEN2 HIDDEN2 WWF DASHED2 DASHED2 Yes Yes Yes Yes Yes Yes

PILES REINFORCMENT

ROOF TRUSS WALL S WALL HIDN ____ TEMP 46 HIDDEN2 Yes

Last Updated: March 2010

Page 239

Engineering Department Manual


E/A Design Division CAD Standard

6.23.3 LINETYPES Name


Continuous Description Continuous Example

DASHED

Dashed (1x)

DIVIDE

Divide (1x)

Last Updated: March 2010

Page 240

Engineering Department Manual


E/A Design Division CAD Standard

6.23.4 SYMBOLS 6.23.4.1


Symbol

MISCELLANEOUS
Block Name CALLOUT.dwg Layer Name (Varies) Description Callout Symbol

CLine.dwg

S-ANNO-SYMB

Center Line

Col-Bubble1.dwg

S-GNRL-BUBL

Column Bubble

Col-Bubble2.dwg

S-GNRL-BUBL

Column Bubble

DET-SYMB.dwg

S-ANNO-SYMB

Detail Callout

Legend1.dwg

S-ANNO-SYMB

Legend

N_Arrow.dwg

S-ANNO-SYMB

North Arrow

Plate.dwg

S-ANNO-SYMB

Plate

Rev-Tr.dwg

(Varies)

Revision Tag

Sec1.dwg

S-ANNO-SYMB

Section, Detail, Elevation Callout, View to North

Sec2.dwg

S-ANNO-SYMB

Section, Detail, Elevation Callout, View to North

Sec3.dwg

S-ANNO-SYMB

Section, Detail, Elevation Callout, View to South

Last Updated: March 2010

Page 241

Engineering Department Manual


E/A Design Division CAD Standard

Sec4.dwg

S-ANNO-SYMB

Section, Detail, Elevation Callout, View to South

Sec5.dwg

S-ANNO-SYMB

Section, Detail, Elevation Callout, View to West

Sec6.dwg

S-ANNO-SYMB

Section, Detail, Elevation Callout, View to East

Sec7.dwg

S-ANNO-SYMB

Section, Detail, Elevation Callout, View to West

Sec8.dwg

S-ANNO-SYMB

Section, Detail, Elevation Callout, View to East

Sect-Mk_Detail.dwg

S-ANNO-SYMB

Section Mark Symbol

Stamp1.dwg

S-ANNO-SYMB

Percent Complete/Date Stamp

Sub-Title.dwg

S-ANNO-SUBT

Sub-Title

Title.dwg

S-ANNO-TITL

Title

WF.dwg

S-ANNO-SYMB

Wide Flange (Depth WF Weight)

Last Updated: March 2010

Page 242

Engineering Department Manual


E/A Design Division CAD Standard

6.24

APPENDIX H TRAFFIC DISCIPLINE

6.24.1 CONTENT PREFERENCES This Section Currently Under Construction

Last Updated: March 2010

Page 243

Engineering Department Manual


E/A Design Division CAD Standard

6.24.2 LAYER STRATAGEM 6.24.2.1


Discipline

NEW WORK
Linetype

Phase

Minor

Major

Color

Plots

Desc

Description

ANNOTATION T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T ANNO ANNO ANNO ANNO ANNO ANNO ANNO ANNO ANNO ANNO DVCS DVCS DVCS DVCS DVCS DVCS DVCS DVCS DVCS DVCS DVCS DVCS MARK MARK MARK MARK MARK MARK MARK MARK MARK MARK HIDN _BLL _DOT NJTP DLLL DLLS DIMS SYMB TEXT ATTN BARR BARR BARR DIMS DLIN FENC GDRL GDRL GDRL TEXT _BOX _WBM THRI _WFB CONC TMBR DIMS MLIN NPLT SYMB TEXT TTLB REVS REVS VPRT 0001 TEXT 212 37 13 7 110 212 110 80 212 7 110 110 110 110 110 37 110 110 110 110 110 212 220 220 220 220 220 220 220 37 220 212 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Hidden BrokenLane NJDOT NJTPK DottedLane4 DottedLane2 Continuous Continuous Continuous Yes Yes Yes No Yes Yes Yes Yes Yes No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Generic Annotation Features Dimensions Match Lines Non Plot Features Generic Symbols Miscellaneous Annotations and Callouts Title Block and Contract Border Information Revision Cloud - PACC Revision Delta and Text in Drawing & Contract Border Viewport Generic Device Features Impact Attenuator Water Filled Barriers Concrete Barriers Timber Barriers Device Dimensions Delineator Fencing Box Beam Guide Rail W Beam Guide Rail Thrie Beam Guide Rail Device Annotations Generic Pavement Markings Pavement Markings Obscured by Other Objects Broken Lane Line - 15-25 NJ DOT - 10-30 NJ Turnpike Lane Line - 30-10 Dotted Lane Line - 2-4 Dotted Lane Line - 2-2 Pavement Marking Dimensions Marking Symbols - Directional Arrows Marking Annotations and Leaders

DEVICES

MARKINGS

Last Updated: March 2010

Page 244

Engineering Department Manual


E/A Design Division CAD Standard
T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T MARK SGNL SGNL SGNL SGNL SGNL SGNL SGNL SGNL SGNL SIGN SIGN SIGN SIGN PAVE PAVE PAVE PAVE PAVE PAVE PAVE PAVE PAVE PAVE PAVE SITE SITE SITE SITE SITE SITE SITE SITE SITE SITE SITE SITE XREF XREF RAST ABUT ABVE BLDG BLDG COLS FNCE FNDN LAND SWLK TEXT WALL TEXT ASPH BRDR CONC CURB CURB DIMS GRAV JBAR JNTS LIMT BACK FACE PATT DIMS SYMB TEXT ABVE COND DIMS DIMS JBOX LOOP TEXT TEXT HEAD POLE HEAD WORD 220 110 110 110 37 37 110 110 212 212 110 37 110 212 80 12 14 12 1 131 37 12 220 220 13 80 131 250 212 131 191 131 131 131 80 212 131 7 7 Continuous Continuous Continuous Dashed Continuous Continuous Continuous Dashed Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Dashed Continuous Continuous Continuous Continuous Continuous Continuous FENCE Continuous Continuous Continuous Continuous Continuous Continuous Continuous Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Marking Words - Stop/MPH/etc. Generic Signal Features Above Ground Signal Equipment Signal Conduit Signal Pole Location Dimensions Signal Head Dimensions Signal Junction Box Signal Loop or Video Zone Signal Annotations Signal Head Annotations Sign Panels Sign Dimensions and Leaders Sign Symbols Sign Annotations and Callouts Paving Features Asphalt Pavement Pavement Hatch Borders Concrete Pavement Back of Curb Face of Curb Pavement Dimensions Gravel Pavement Jersey Barriers Expansion Joints Paving Limits Site Features Bridge Abutments Site Elements Overhead Building and Shed Annotations Building and Shed Features Columns, Piers and Posts Fence Lines Foundations Landscape Features Sidewalk Sitework Text Walls External Reference Drawings Raster Images

SIGNALS

SIGNS

PAVING

SITE PLANS

XREFS

Last Updated: March 2010

Page 245

Engineering Department Manual


E/A Design Division CAD Standard 6.24.2.2
Discipline

EXISTING WORK
Linetype

Phase

Minor

Major

Color

Plots

Desc

Description

Default Existing Layer Properties (Unless Otherwise Noted Below) T EXST 253 ____ ____ ____ Dashed Yes ANNOTATION T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T ANNO ANNO DVCS DVCS DVCS DVCS DVCS DVCS DVCS DVCS DVCS DVCS DVCS DVCS MARK MARK MARK MARK MARK MARK MARK MARK MARK MARK MARK SGNL SGNL SGNL SGNL SGNL SGNL SGNL SGNL ABVE COND DIMS DIMS JBOX TEXT TEXT HIDN _BLL _DOT NJTP DLLL DLLS DIMS SYMB TEXT WORD ATTN BARR BARR BARR DIMS DLIN FENC GDRL GDRL GDRL TEXT DIMS TEXT ____ ____ ____ ____ _WFB CONC TMBR ____ ____ ____ _BOX _WBM THRI ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ POLE HEAD ____ ____ HEAD EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST 37 212 253 253 253 253 253 37 253 253 253 253 253 212 253 253 253 253 253 253 253 37 253 212 253 253 253 253 37 37 253 212 212 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Hidden BrokenLane NJDOT NJTPK DottedLane4 DottedLane2 Continuous Continuous Continuous Continuous Continuous Continuous Dashed Continuous Continuous Continuous Continuous Continuous Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Existing Dimensions Existing Miscellaneous Annotations And Callouts Existing Generic Device Features Existing Impact Attenuator Existing Water Filled Barriers Existing Concrete Barriers Existing Timber Barriers Existing Device Dimensions Existing Delineator Existing Fencing Existing Box Beam Guide Rail Existing W Beam Guide Rail Existing Thrie Beam Guide Rail Existing Device Annotations Existing Generic Pavement Markings Existing Pavement Markings Obscured By Other Objects Existing Broken Lane Line - 15-25 Existing Nj Dot - 10-30 Existing Nj Turnpike Lane Line - 30-10 Existing Dotted Lane Line - 2-4 Existing Dotted Lane Line - 2-2 Existing Pavement Marking Dimensions Existing Marking Symbols - Directional Arrows Existing Marking Annotations And Leaders Existing Marking Words - Stop/Mph/Etc. Existing Generic Signal Features Existing Above Ground Signal Equipment Existing Signal Conduit Existing Signal Pole Location Dimensions Existing Signal Head Dimensions Existing Signal Junction Box Existing Signal Annotations Existing Signal Head Annotations

DEVICES

MARKINGS

SIGNALS

Last Updated: March 2010

Page 246

Engineering Department Manual


E/A Design Division CAD Standard
SIGNS T T T T T T T T T T T T T T T T T T T T T T T T T T SIGN SIGN SIGN SIGN PAVE PAVE PAVE PAVE PAVE PAVE PAVE PAVE PAVE PAVE SITE SITE SITE SITE SITE SITE SITE SITE SITE SITE SITE SITE ABUT ABVE BLDG BLDG COLS FNCE FNDN LAND SWLK TEXT WALL ASPH BRDR CONC CURB CURB DIMS GRAV JBAR JNTS DIMS SYMB TEXT ____ ____ ____ ____ ____ ____ PATT ____ BACK FACE ____ ____ ____ ____ ____ ____ ____ TEXT ____ ____ ____ ____ ____ ____ ____ ____ EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST EXST 253 37 253 212 253 253 253 253 253 253 37 253 253 253 253 253 253 212 253 253 253 253 253 253 212 253 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous FENCE Continuous Continuous Continuous Continuous Continuous Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Existing Sign Panels Existing Sign Dimensions And Leaders Existing Sign Symbols Existing Sign Annotations And Callouts Existing Paving Features Existing Asphalt Pavement Existing Pavement Hatch Borders Existing Concrete Pavement Existing Back Of Curb Existing Face Of Curb Existing Pavement Dimensions Existing Gravel Pavement Existing Jersey Barriers Existing Expansion Joints Existing Site Features Existing Bridge Abutments Existing Site Elements Overhead Existing Building And Shed Annotations Existing Building And Shed Features Existing Columns, Piers And Posts Existing Fence Lines Existing Foundations Existing Landscape Features Existing Sidewalk Existing Sitework Text Existing Walls

PAVING

SITE PLANS

6.24.2.3
Discipline

FUTURE WORK
Linetype

Phase

Minor

Major

Color

Plots

Desc

Description

Default Future Layer Properties (Unless Otherwise Noted Below) T FUTR 21 ____ ____ ____ Continuous Yes MARKINGS 21 T MARK HIDN ____ FUTR Hidden Yes 21 T MARK _BLL ____ FUTR BrokenLane Yes 21 T MARK _DOT ____ FUTR NJDOT Yes 21 T MARK NJTP ____ FUTR NJTPK Yes 21 T MARK DLLL ____ FUTR DottedLane4 Yes 21 T MARK DLLS ____ FUTR DottedLane2 Yes

Future Pavement Markings Obscured By Other Objects Future Broken Lane Line - 15-25 Future Nj Dot - 10-30 Future Nj Turnpike Lane Line - 30-10 Future Dotted Lane Line - 2-4 Future Dotted Lane Line - 2-2

Last Updated: March 2010

Page 247

Engineering Department Manual


E/A Design Division CAD Standard
SIGNALS T SGNL T SGNL PAVING T PAVE SITE PLANS T SITE

COND LOOP LIMT FNCE

____ ____ ____ ____

FUTR FUTR FUTR FUTR

21 21 21 21

Dashed Dashed Dashed FENCE

Yes Yes Yes Yes

Future Signal Conduit Future Signal Loop Or Video Zone Future Paving Limits Future Fence Lines

6.24.2.4

MAINTENANCE OF TRAFFIC WORK

Discipline

Linetype

Phase

Minor

Major

Color

Plots

Desc

Description

Default Maintenance of Traffic Layer Properties (Unless Otherwise Noted Below) T _MPT 21 ____ ____ ____ Continuous Yes ANNOTATION T T T T T T T T T T T T T T T T T T T T T T T T T ANNO ANNO DVCS DVCS DVCS DVCS DVCS DVCS DVCS DVCS DVCS DVCS DVCS DVCS MARK MARK MARK MARK MARK MARK MARK MARK MARK MARK MARK HIDN _BLL _DOT NJTP DLLL DLLS DIMS SYMB TEXT WORD ATTN BARR BARR BARR DIMS DLIN FENC GDRL GDRL GDRL TEXT DIMS TEXT ____ ____ ____ ____ _WFB CONC TMBR ____ ____ ____ _BOX _WBM THRI ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ _MPT _MPT _MPT _MPT _MPT _MPT _MPT _MPT _MPT _MPT _MPT _MPT _MPT _MPT _MPT _MPT _MPT _MPT _MPT _MPT _MPT _MPT _MPT _MPT _MPT 37 212 110 110 110 110 110 37 110 110 110 110 110 212 220 220 220 220 220 220 220 37 220 212 220 Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Hidden BrokenLane NJDOT NJTPK DottedLane4 DottedLane2 Continuous Continuous Continuous Continuous Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Maintenance Of Traffic (MPT) Patterns Dimensions MPT Patterns Miscellaneous Annotations And Callouts MPT Patterns Generic Device Features MPT Patterns Impact Attenuator MPT Patterns Water Filled Barriers MPT Patterns Concrete Barriers MPT Patterns Timber Barriers MPT Patterns Device Dimensions MPT Patterns Delineator MPT Patterns Fencing MPT Patterns Box Beam Guide Rail MPT Patterns W Beam Guide Rail MPT Patterns Thrie Beam Guide Rail MPT Patterns Device Annotations MPT Patterns Generic Pavement Markings MPT Patterns Pavement Markings Obscured By Other MPT Patterns Broken Lane Line - 15-25 MPT Patterns Nj Dot - 10-30 MPT Patterns Nj Turnpike Lane Line - 30-10 MPT Patterns Dotted Lane Line - 2-4 MPT Patterns Dotted Lane Line - 2-2 MPT Patterns Pavement Marking Dimensions MPT Patterns Marking Symbols - Directional Arrows MPT Patterns Marking Annotations And Leaders MPT Patterns Marking Words - Stop/Mph/Etc.

DEVICES

MARKINGS

SIGNALS

Last Updated: March 2010

Page 248

Engineering Department Manual


E/A Design Division CAD Standard
T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T SGNL SGNL SGNL SGNL SGNL SGNL SGNL SGNL SGNL SIGN SIGN SIGN SIGN PAVE PAVE PAVE PAVE PAVE PAVE PAVE PAVE PAVE PAVE PAVE SITE SITE SITE SITE SITE SITE SITE SITE SITE SITE SITE SITE ABUT ABVE BLDG BLDG COLS FNCE FNDN LAND SWLK TEXT WALL ASPH BRDR CONC CURB CURB DIMS GRAV JBAR JNTS LIMT DIMS SYMB TEXT ABVE COND DIMS DIMS JBOX LOOP TEXT TEXT ____ ____ ____ POLE HEAD ____ ____ ____ HEAD ____ ____ ____ ____ ____ ____ PATT ____ BACK FACE ____ ____ ____ ____ ____ ____ ____ ____ TEXT ____ ____ ____ ____ ____ ____ ____ ____ _MPT _MPT _MPT _MPT _MPT _MPT _MPT _MPT _MPT _MPT _MPT _MPT _MPT _MPT _MPT _MPT _MPT _MPT _MPT _MPT _MPT _MPT _MPT _MPT _MPT _MPT _MPT _MPT _MPT _MPT _MPT _MPT _MPT _MPT _MPT _MPT 110 110 110 37 37 110 110 212 212 110 37 110 212 80 12 14 12 1 131 37 12 220 220 13 80 131 250 212 131 191 131 131 131 80 212 131 Continuous Continuous Dashed Continuous Continuous Continuous Dashed Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Continuous Dashed Continuous Continuous Continuous Continuous Continuous Continuous FENCE Continuous Continuous Continuous Continuous Continuous Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes MPT Patterns Generic Signal Features MPT Patterns Above Ground Signal Equipment MPT Patterns Signal Conduit MPT Patterns Signal Pole Location Dimensions MPT Patterns Signal Head Dimensions MPT Patterns Signal Junction Box MPT Patterns Signal Loop Or Video Zone MPT Patterns Signal Annotations MPT Patterns Signal Head Annotations MPT Patterns Sign Panels MPT Patterns Sign Dimensions And Leaders MPT Patterns Sign Symbols MPT Patterns Sign Annotations And Callouts MPT Patterns Paving Features MPT Patterns Asphalt Pavement MPT Patterns Pavement Hatch Borders MPT Patterns Concrete Pavement MPT Patterns Back Of Curb MPT Patterns Face Of Curb MPT Patterns Pavement Dimensions MPT Patterns Gravel Pavement MPT Patterns Jersey Barriers MPT Patterns Expansion Joints MPT Patterns Paving Limits MPT Patterns Site Features MPT Patterns Bridge Abutments MPT Patterns Site Elements Overhead MPT Patterns Building And Shed Annotations MPT Patterns Building And Shed Features MPT Patterns Columns, Piers And Posts MPT Patterns Fence Lines MPT Patterns Foundations MPT Patterns Landscape Features MPT Patterns Sidewalk MPT Patterns Sitework Text MPT Patterns Walls

SIGNS

PAVING

SITE PLANS

Last Updated: March 2010

Page 249

Engineering Department Manual


E/A Design Division CAD Standard 6.24.2.5
Discipline Minor Major

RELOCATED WORK
Linetype Phase Color

Plots

Desc

Description

Default Relocated Layer Properties (Unless Otherwise Noted Below) T RELO ____ ____ ____ 21 Continuous Yes ANNOTATION MARKINGS T T T T T T T T T T MARK MARK MARK MARK MARK MARK SGNL SGNL PAVE SITE HIDN _BLL _DOT NJTP DLLL DLLS COND LOOP LIMT FNCE ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ RELO RELO RELO RELO RELO RELO RELO RELO RELO RELO 21 21 21 21 21 21 21 21 21 21 Hidden BrokenLane NJDOT NJTPK DottedLane4 DottedLane2 Dashed Dashed Dashed FENCE Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Relocated Pavement Markings Obscured By Other Object Relocated Broken Lane Line - 15-25 Relocated Nj Dot - 10-30 Relocated Nj Turnpike Lane Line - 30-10 Relocated Dotted Lane Line - 2-4 Relocated Dotted Lane Line - 2-2 Relocated Signal Conduit Relocated Signal Loop Or Video Zone Relocated Paving Limits Relocated Fence Lines

SIGNALS

PAVING SITE PLANS

6.24.2.6
Discipline

REMOVAL WORK
Linetype

Phase

Minor

Major

Color

Plots

Desc

Description

Default Removal Layer Properties (Unless Otherwise Noted Below) T RMVL ____ ____ ____ 21 Continuous Yes ANNOTATION T ANNO T ANNO DEVICES T DVCS T DVCS T DVCS T DVCS T DVCS T DVCS T DVCS T DVCS T DVCS T DVCS T DVCS DIMS TEXT ____ ____ ____ ____ _WFB CONC TMBR ____ ____ ____ _BOX _WBM THRI RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL 37 212 21 21 21 21 21 37 21 21 21 21 21 Continuous Continuous Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Continuous Hidden2 Hidden2 Hidden2 Hidden2 Hidden2 Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Removal Of Dimensions Removal Of Miscellaneous Annotations And Callouts Removal Of Generic Device Features Removal Of Impact Attenuator Removal Of Water Filled Barriers Removal Of Concrete Barriers Removal Of Timber Barriers Removal Of Device Dimensions Removal Of Delineator Removal Of Fencing Removal Of Box Beam Guide Rail Removal Of W Beam Guide Rail Removal Of Thrie Beam Guide Rail

ATTN BARR BARR BARR DIMS DLIN FENC GDRL GDRL GDRL

Last Updated: March 2010

Page 250

Engineering Department Manual


E/A Design Division CAD Standard
T DVCS MARKINGS T MARK T MARK TEXT ____ ____ HIDN _BLL _DOT NJTP DLLL DLLS DIMS SYMB TEXT WORD ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ POLE HEAD ____ ____ ____ HEAD ____ ____ ____ ____ ____ ____ PATT ____ BACK FACE ____ ____ ____ ____ ____ ____ ____ ____ TEXT ____ ____ ____ ____ ____ ____ RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL RMVL 212 50 50 50 50 50 50 50 37 50 212 50 21 21 37 37 21 21 212 212 21 37 21 212 54 148 143 148 148 31 37 148 50 50 150 54 31 250 212 31 2 31 31 31 54 Continuous Continuous Hidden BrokenLane NJDOT NJTPK DottedLane4 DottedLane2 Continuous Continuous Continuous Continuous Hidden2 Hidden2 Continuous Continuous Hidden2 Hidden2 Continuous Continuous Hidden2 Continuous Hidden2 Continuous Continuous Hidden2 Continuous Hidden2 Hidden2 Hidden2 Continuous Hidden2 Hidden2 Hidden2 Dashed Hidden2 Hidden2 Continuous Continuous Hidden2 Hidden2 FENCE Hidden2 Hidden2 Hidden2 Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Removal Of Device Annotations Removal Of Generic Pavement Markings Removal Of Pavement Markings Obscured By Other Objects Removal Of Broken Lane Line - 15-25 Removal Of Nj Dot - 10-30 Removal Of Nj Turnpike Lane Line - 30-10 Removal Of Dotted Lane Line - 2-4 Removal Of Dotted Lane Line - 2-2 Removal Of Pavement Marking Dimensions Removal Of Marking Symbols - Directional Arrows Removal Of Marking Annotations And Leaders Removal Of Marking Words - Stop/Mph/Etc. Removal Of Generic Signal Features Removal Of Signal Conduit Removal Of Signal Pole Location Dimensions Removal Of Signal Head Dimensions Removal Of Signal Junction Box Removal Of Signal Loop Or Video Zone Removal Of Signal Annotations Removal Of Signal Head Annotations Removal Of Sign Panels Removal Of Sign Dimensions And Leaders Removal Of Sign Symbols Removal Of Sign Annotations And Callouts Removal Of Paving Features Removal Of Asphalt Pavement Removal Of Pavement Hatch Borders Removal Of Concrete Pavement Removal Of Back Of Curb Removal Of Face Of Curb Removal Of Pavement Dimensions Removal Of Gravel Pavement Removal Of Jersey Barriers Removal Of Expansion Joints Removal Of Paving Limits Removal Of Site Features Removal Of Bridge Abutments Removal Of Site Elements Overhead Removal Of Building And Shed Annotations Removal Of Building And Shed Features Removal Of Columns, Piers And Posts Removal Of Fence Lines Removal Of Foundations Removal Of Landscape Features Removal Of Sidewalk

T MARK T MARK T MARK T MARK T MARK T MARK T MARK T MARK T MARK SIGNALS T SGNL T SGNL T SGNL T SGNL T SGNL T SGNL T SGNL T SGNL SIGNS T SIGN T SIGN T SIGN T SIGN PAVING T PAVE T PAVE T PAVE T PAVE T PAVE T PAVE T PAVE T PAVE T PAVE T PAVE T PAVE SITE PLANS T SITE T SITE T SITE T SITE T SITE T SITE T SITE T SITE T SITE T SITE

COND DIMS DIMS JBOX LOOP TEXT TEXT

DIMS SYMB TEXT

ASPH BRDR CONC CURB CURB DIMS GRAV JBAR JNTS LIMT

ABUT ABVE BLDG BLDG COLS FNCE FNDN LAND SWLK

Last Updated: March 2010

Page 251

Engineering Department Manual


E/A Design Division CAD Standard
T T SITE SITE TEXT WALL ____ ____ RMVL RMVL 212 31 Continuous Hidden2 Yes Yes Removal Of Sitework Text Removal Of Walls

6.24.2.7
Discipline Minor Major

TEMPORARY WORK
Linetype Phase Color Plots Desc

Description

Default Temporary Layer Properties (Unless Otherwise Noted Below) T TEMP ____ ____ ____ 21 Continuous Yes MARKINGS T T T T T T T T T T MARK MARK MARK MARK MARK MARK SGNL SGNL PAVE SITE HIDN _BLL _DOT NJTP DLLL DLLS COND LOOP LIMT FNCE ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ TEMP TEMP TEMP TEMP TEMP TEMP TEMP TEMP TEMP TEMP 21 21 21 21 21 21 21 21 21 21 Hidden BrokenLane NJDOT NJTPK DottedLane4 DottedLane2 Dashed Dashed Dashed FENCE Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Temporary Pavement Markings Obscured By Other Objects Temporary Broken Lane Line - 15-25 Temporary NJ Dot - 10-30 Temporary NJ Turnpike Lane Line - 30-10 Temporary Dotted Lane Line - 2-4 Temporary Dotted Lane Line - 2-2 Temporary Signal Conduit Temporary Signal Loop Or Video Zone Temporary Paving Limits Temporary Fence Lines

SIGNALS

PAVING SITE PLANS

Last Updated: March 2010

Page 252

Engineering Department Manual


E/A Design Division CAD Standard

6.24.3 LINETYPES Name


Continuous Description Continuous Example

DASHED

Dashed (1x)

DIVIDE

Divide (1x)

Last Updated: March 2010

Page 253

Engineering Department Manual


E/A Design Division CAD Standard

6.24.4 SYMBOLS 6.24.4.1


Symbol

EXISTING
Block Name CANTILEVER SIGN STRUCTURE WITH CHANGEABLE MESSAGE PANELEXISTING.dwg CANTILEVER SIGN STRUCTURE WITH FIXED MESSAGE-EXISTING.dwg Layer Name (Varies) Description Cantilever Sign Structure with Changeable Message Panel Cantilever Sign Structure with Fixed Message

(Varies)

CRASH CUSHION ATTENUATOREXISTING.dwg CURBED TRAFFIC GUIDE SYSTEM POSTS WITH BASE PLATE (WITHOUT C)-EXISTING.dwg DIRECTION OF TRAFFIC (PERMANENT CONDITIONS)-EXISTING.dwg DOUBLE POST MOUNTED SIGN WITH CHANGEABLE MESSAGE PANELEXISTING.dwg EXISTING SIGN PANEL TO BE MODIFIED-EXISTING.dwg

(Varies)

Crash Cushion Attenuator

(Varies)

Curbed Traffic Guide System Posts with Base Plate (Without C) Direction of Traffic (Permanent Conditions) Double Post-Mounted Sign with Changeable Message Panel Existing Sign Panel to be Modified

(Varies)

(Varies)

(Varies)

FENCE MOUNTED SIGN WITH FIXED MESSAGE PANEL-EXISTING.dwg GANTRY SIGN STRUCTURE WITH CHANGEABLE MESSAGE PANELSEXISTING.dwg GANTRY SIGN STRUCTURE WITH FIXED MESSAGE PANELSEXISTING.dwg PAVEMENT MARKING ARROW SYMBOL (TYPE A-E)-EXISTING.dwg

(Varies)

Fence-Mounted Sign With Fixed Message Panel Gantry Sign Structure with Changeable Message Panels Gantry Sign Structure with Fixed Message Panels

(Varies)

(Varies)

(Varies)

Pavement Marking Arrow Symbol (Type A-E)

PAVEMENT MARKING LINEEXISTING.dwg

(Varies)

Pavement Marking Line

Last Updated: March 2010

Page 254

Engineering Department Manual


E/A Design Division CAD Standard
PEDESTRIAN PUSH BUTTON STANDARD WITH IDENTIFIEREXISTING.dwg POLE MOUNTED BACK TO BACK SIGNS WITH FIXED MESSAGE PANELS-EXISTING.dwg POLE MOUNTED RIGHT ANGLE SIGNS WITH FIXED MESSAGE PANELSEXISTING.dwg POLE MOUNTED SIGN WITH FIXED MESSAGE PANEL-EXISTING.dwg POST MOUNTED BACK TO BACK SIGNS WITH FIXED MESSAGE PANELS-EXISTING.dwg POST MOUNTED RIGHT ANGLE SIGNS WITH FIXED MESSAGE PANELSEXISTING.dwg POST MOUNTED SIGN WITH FIXED MESSAGE PANEL-EXISTING.dwg

(Varies)

Pedestrian Push-Button Standard with Identifier Pole-Mounted Back-toBack Signs with Fixed Message Panels Pole-Mounted Right Angle Signs with Fixed Message Panels Pole-Mounted Sign with Fixed Message Panel Post-Mounted Back-toBack Signs with Fixed Message Panels Post-Mounted Right-Angle Signs with Fixed Message Panels Post-Mounted Sign with Fixed Message Panel

(Varies)

(Varies)

(Varies)

(Varies)

(Varies)

(Varies)

REFLECTORIZED PAVEMENT MARKER-EXISTING.dwg

(Varies)

Reflectorized Pavement Marker

ROADWAY SURVEILLANCE SENSOR WITH IDENTIFIER-EXISTING.dwg

(Varies)

Roadway Surveillance Sensor with Identifier

SAND BARREL ARRAY-EXISTING.dwg

(Varies)

Sand-Barrel Array

SIGN PANEL IDENTIFIEREXISTING.dwg

(Varies)

Sign Panel Identifier

SIGN STRUCTURE LOCATION IDENTIFIER-EXISTING.dwg

(Varies)

Sign Structure Location Identifier

SIGNAL CONTROLLER AND CABINET GROUND MOUNTED-EXISTING.dwg

(Varies)

Signal Controller and Cabinet, Pole-Mounted

Last Updated: March 2010

Page 255

Engineering Department Manual


E/A Design Division CAD Standard

SIGNAL CONTROLLER AND CABINET POLE MOUNTED-EXISTING.dwg

(Varies)

Signal Controller and Cabinet, Pole-Mounted

TRAFFIC GUIDE POSTS-EXISTING.dwg

(Varies)

Traffic Guide Posts

TRAFFIC POST TOP SIDE OF POLE MOUNTED SIGNAL-EXISTING.dwg TRAFFIC SIGNAL SPAN WIRE INSTALLATION WITH SPAN LENGTHEXISTING.dwg TRAFFIC SIGNAL STANDARD WITH IDENTIFIER-EXISTING.dwg

(Varies)

Traffic Post Top Side of Pole-Mounted Signal Traffic Signal Span Wire Installation with Span Length Traffic Signal Standard with Identifier

(Varies)

(Varies)

TRAFFIC SIGNAL STANDARD WITH MAST ARM LENGTH-EXISTING.dwg

(Varies)

Traffic Signal Standard with Mast Arm Length

VEHICULAR SIGNAL HEAD WITH IDENTIFIER-EXISTING.dwg

(Varies)

Vehicular Signal Head with Identifier

6.24.4.2
Symbol

GUIDE
Block Name D9-5.dwg Layer Name (Varies) Description Reserved Handicapped Parking

E5-1.dwg

(Varies)

Exit to Right in Distance

E5-1L.dwg

(Varies)

Exit to Left Immediate

E5-1Lx.dwg

(Varies)

Exit to Left in Distance

E5-1R.dwg

(Varies)

Exit to Right Immediate

Last Updated: March 2010

Page 256

Engineering Department Manual


E/A Design Division CAD Standard

E5-1Rx.dwg

(Varies)

Exit to Right in Distance

G20-1f.dwg

(Varies)

Road Work Ahead Sign

G20-2.DWG

(Varies)

End Road Work Sign

M1-1.DWG

(Varies)

Interstate Route Number Sign

M1-4-3..DWG

(Varies)

Interstate Route Number Sign 3 Digits

M1-4.DWG

(Varies)

Roadway Route Number Sign 2 Digits

M1-5.DWG

(Varies)

Roadway Route Number Sign 2 Digits

M2-1.DWG

(Varies)

Juncture Sign

M3-1.DWG

(Varies)

North Sign

M3-2.DWG

(Varies)

East Sign

M3-3.DWG

(Varies)

South Sign

M3-4.DWG

(Varies)

West Sign

M4-1.DWG

(Varies)

Alternate Sign

Last Updated: March 2010

Page 257

Engineering Department Manual


E/A Design Division CAD Standard

M4-1a.dwg

(Varies)

ALT Sign

M4-2.DWG

(Varies)

By-Pass Sign

M4-3.dwg

(Varies)

Business Sign

M4-4.dwg

(Varies)

Truck Sign

M4-5.dwg

(Varies)

To Sign

M4-6.dwg

(Varies)

End Sign

M4-7.dwg

(Varies)

Temporary Sign

M4-8.dwg

(Varies)

Detour Sign

M4-8a.dwg

(Varies)

End Detour Sign

M4-9l.dwg

(Varies)

Detour Left

M4-9lx.dwg

(Varies)

Detour Left, In Distance

M4-9r.dwg

(Varies)

Detour Right

M4-9rx.dwg

(Varies)

Detour Right, In Distance

Last Updated: March 2010

Page 258

Engineering Department Manual


E/A Design Division CAD Standard

M4-9x.dwg

(Varies)

Detour Ahead

M4-10l.dwg

(Varies)

Detour Turn Left

M4-10r.dwg

(Varies)

Detour Turn Right

M5-1L.dwg

(Varies)

Left Turn Ahead

M5-1R.dwg

(Varies)

Right Turn Ahead

M5-2L.dwg

(Varies)

Approaching Left Turn

M5-2R.dwg

(Varies)

Approaching Right Turn

M6-1l.dwg

(Varies)

Turn Left

M6-1r.dwg

(Varies)

Turn Right

M6-2l.dwg

(Varies)

Merge Left

M6-2r.dwg

(Varies)

Merge Right

M6-3.dwg

(Varies)

Continue Straight

M6-4.dwg

(Varies)

Must Turn Left or Right

Last Updated: March 2010

Page 259

Engineering Department Manual


E/A Design Division CAD Standard

M6-5l.dwg

(Varies)

Must Bear Left or Turn Right

M6-5r.dwg

(Varies)

Must Bear Right or Turn Left

M6-6L.dwg

(Varies)

Lane Must Proceed Straight or Turn Left

M6-6R.dwg

(Varies)

Lane Must Proceed Straight or Turn Right

M6-7L.dwg

(Varies)

Lane Must Proceed Straight or Bear Left

M6-7R.dwg

(Varies)

Lane Must Proceed Straight or Bear Right

6.24.4.3
Symbol

MARKER
Block Name ERM-1818YY.dwg Layer Name (Varies) Description Diamond Reflector Sign Bright Color

OM-3L.DWG

(Varies)

Rectangular Reflector Sign Diagonals, Up to Left Rectangular Reflective Sign Diagonals, Up to Right Rectangular Reflective Sign Blank

OM-3R.DWG

(Varies)

OM-612-3.DWG

(Varies)

OM-612.DWG

(Varies)

Rectangular Reflective Sign Circular Reflectors

OM-1818Y.DWG

(Varies)

Diamond Reflective Sign

Last Updated: March 2010

Page 260

Engineering Department Manual


E/A Design Division CAD Standard

OM-1818YB.dwg

(Varies)

Diamond Reflector Sign Dark Color

6.24.4.4
Symbol

MISCELLANEOUS
Block Name LIGHT.DWG Layer Name (Varies) Description Single Light Symbol

LIGHTS.DWG

(Varies)

Two Lights Symbol

S-3.DWG

(Varies)

Bridge Will be Closed Sign

S-4.DWG

(Varies)

Plan Alt. Route Sign

6.24.4.5
Symbol

PROPOSED
Block Name BACK-UP VEHICLE WITH FLASHING LIGHTS ONLY-PROPOSED.dwg BACK-UP VEHICLE WITH IMPACT ATTENUATOR AND FASUPROPOSED.dwg BACK-UP VEHICLE WITH IMPACT ATTENUATOR WITHOUT FASUPROPOSED.dwg BREAKAWAY BARRICADES (TYPE III) WITH ATTACHED SIGNPROPOSED.dwg BREAKAWAY BARRICADES (TYPE III)PROPOSED.dwg CANTILEVER SIGN STRUCTURE WITH CHANGEABLE MESSAGE PANELPROPOSED.dwg Layer Name (Varies) Description Back-Up Vehicle with Flashing Lights Only Back-Up Vehicle with Impact Attenuator and FASU Back-Up Vehicle with Impact Attenuator without FASU Breakaway Barricades (Type III), with Attached Sign Breakaway Barricades (Type III) Cantilever Sign Structure with Changeable Message Panel

(Varies)

(Varies)

(Varies)

(Varies)

(Varies)

Last Updated: March 2010

Page 261

Engineering Department Manual


E/A Design Division CAD Standard

CANTILEVER SIGN STRUCTURE WITH FIXED MESSAGE-PROPOSED.dwg

(Varies)

Cantilever Sign Structure with Fixed Message

CONTRACTORS VEHICLEPROPOSED.dwg

(Varies)

Contractors Vehicle

CRASH CUSHION ATTENUATORPROPOSED.dwg

(Varies)

Crash Cushion Attenuator

CURBED TRAFFIC GUIDE SYSTEM POSTS WITH BASE PLATE (WITHOUT C)-PROPOSED.dwg DIRECTION OF DETOUR (TEMPORARY TRAFFIC FLOW)-PROPOSED.dwg

(Varies)

Curbed Traffic Guide System Posts with Base Plate (Without C) Direction of Detour (Temporary Traffic Flow)

(Varies)

DIRECTION OF HAUL ROUTEPROPOSED.dwg

(Varies)

Direction of Haul Route

DIRECTION OF TRAFFIC (PERMANENT CONDITIONS)-PROPOSED.dwg DOUBLE POST MOUNTED SIGN WITH CHANGEABLE MESSAGE PANELPROPOSED.dwg FENCE MOUNTED SIGN WITH FIXED MESSAGE PANEL-PROPOSED.dwg

(Varies)

Direction of Traffic (Permanent Conditions) Double Post-Mounted Sign with Changeable Message Panel Fence-Mounted Sign with Fixed Message Panel

(Varies)

(Varies)

FLAGGER LOCATION-PROPOSED.dwg

(Varies)

Flagger Location

FLASHING ARROW SIGN UNIT (FASU) CAUTION MODE INDICATIONPROPOSED.dwg FLASHING ARROW SIGN UNIT (FASU) DOUBLE ARROW INDICATIONPROPOSED.dwg FLASHING ARROW SIGN UNIT (FASU) LEFT ARROW INDICATIONPROPOSED.dwg

(Varies)

Flashing Arrow Sign Unit (FASU) Caution Mode Indication Flashing Arrow Sign Unit (FASU) Double-Arrow Indication Flashing Arrow Sign Unit (FASU) Left Arrow Indication

(Varies)

(Varies)

Last Updated: March 2010

Page 262

Engineering Department Manual


E/A Design Division CAD Standard
FLASHING ARROW SIGN UNIT (FASU) RIGHT ARROW INDICATIONPROPOSED.dwg GANTRY SIGN STRUCTURE WITH CHANGEABLE MESSAGE PANELSPROPOSED.dwg GANTRY SIGN STRUCTURE WITH FIXED MESSAGE PANELSPROPOSED.dwg PAVEMENT MARKING ARROW SYMBOL (TYPE A-E)-PROPOSED.dwg Flashing Arrow Sign Unit (FASU) Right Arrow Indication Gantry Sign Structure with Changeable Message Panels Gantry Sign Structure with Fixed Message Panels

(Varies)

(Varies)

(Varies)

(Varies)

Pavement Marking Arrow Symbol (Type A-E)

PAVEMENT MARKING LINEPROPOSED.dwg PEDESTRIAN PUSH BUTTON STANDARD WITH IDENTIFIERPROPOSED.dwg PEDESTRIAN SIGNAL HEAD WITH IDENTIFIER-PROPOSED.dwg PLASTIC DELINEATOR DRUMS WITH ATTACHED WARNING LIGHTSPROPOSED.dwg PLASTIC DELINEATOR DRUMSPROPOSED.dwg POLE MOUNTED BACK TO BACK SIGNS WITH FIXED MESSAGE PANELS-PROPOSED.dwg POLE MOUNTED RIGHT ANGLE SIGNS WITH FIXED MESSAGE PANELSPROPOSED.dwg POLE MOUNTED SIGN WITH FIXED MESSAGE PANEL-PROPOSED.dwg

(Varies)

Pavement Marking Line

(Varies)

Pedestrian Push-Button Standard with Identifier

(Varies)

Pedestrian Signal Head with Identifier Plastic Delineator Drums with Attached Warning Lights

(Varies)

(Varies)

Plastic Delineator Drums

(Varies)

Pole-Mounted Back-toBack Signs with Fixed Message Panels Pole Mounted Right-Angle Signs with Fixed Message Panels Pole-Mounted Sign with Fixed Message Panel

(Varies)

(Varies)

REFLECTORIZED PAVEMENT MARKER-PROPOSED.dwg

(Varies)

Reflectorized Pavement Marker

Last Updated: March 2010

Page 263

Engineering Department Manual


E/A Design Division CAD Standard

ROADWAY SURVEILLANCE SENSOR WITH IDENTIFIER-PROPOSED.dwg

(Varies)

Roadway Surveillance Sensor with Identifier

SAND BARREL ARRAYPROPOSED.dwg

(Varies)

Sand-Barrel Array

SAND FILLED BARRIERSPROPOSED.dwg

(Varies)

Sand-Filled Barriers

SIGN ON TEMPORARY SIGN STANDPROPOSED.dwg

(Varies)

Sign on Temporary Sign Stand

SIGN PANEL IDENTIFIERPROPOSED.dwg

(Varies)

Sign Panel Identifier

SIGN STRUCTURE LOCATION IDENTIFIER-PROPOSED.dwg

(Varies)

Sign Structure Location Identifier

SIGNAL CONTROLLER AND CABINET GROUND MOUNTED-PROPOSED.dwg

(Varies)

Signal Controller and Cabinet, Ground-Mounted

SIGNAL CONTROLLER AND CABINET POLE MOUNTED-PROPOSED.dwg

(Varies)

Signal Controller and Cabinet, Pole-Mounted

TEMPORARY IMPACT ATTENUATORPROPOSED.dwg

(Varies)

Temporary Impact Attenuator

TEMPORARY REFLECTORIZED PAVEMENT MARKER-PROPOSED.dwg

(Varies)

Temporary Reflectorized Pavement Marker

tra-CALLOUT.dwg

(Varies)

Callout Symbol

tra-DET-SYMB.dwg

(Varies)

Detail Symbol

TRAFFIC CONE-PROPOSED.dwg

(Varies)

Traffic Cone

Last Updated: March 2010

Page 264

Engineering Department Manual


E/A Design Division CAD Standard

TRAFFIC CONES-PROPOSED.dwg

(Varies)

Traffic Cones

TRAFFIC GUIDE POSTSPROPOSED.dwg

(Varies)

Traffic Guide Posts

TRAFFIC LANE OR OTHER AREA CLOSED TO TRAFFIC-PROPOSED.dwg

(Varies)

Traffic Lane or Other Area Closed to Traffic

TRAFFIC POST TOP SIDE OF POLE MOUNTED SIGNAL-PROPOSED.dwg TRAFFIC SIGNAL SPAN WIRE INSTALLATION WITH SPAN LENGTHPROPOSED.dwg TRAFFIC SIGNAL STANDARD WITH IDENTIFIER-PROPOSED.dwg

(Varies)

Traffic Post Top Side of Pole-Mounted Signal Traffic Signal Span Wire Installation with Span Length Traffic Signal Standard with Identifier

(Varies)

(Varies)

TRAFFIC SIGNAL STANDARD WITH MAST ARM LENGTH-PROPOSED.dwg TRAILER MOUNTED FLASHING ARROW SIGN UNIT (FASU)PROPOSED.dwg TRAILER MOUNTED VARIABLE MESSAGE SIGN UNIT (VMSU)PROPOSED.dwg

(Varies)

Traffic Signal Standard with Mast Arm Length

(Varies)

Trailer-Mounted Flashing Arrow Sign Unit (FASU) Trailer-Mounted Flashing Variable Message Sign Unit (VMSU)

(Varies)

tra-SEC-MARK.dwg

(Varies)

Section Mark

VEHICLE DETECTOR WITH IDENTIFIER-PROPOSED.dwg

(Varies)

Vehicle Detector with Identifier

VEHICULAR SIGNAL HEAD WITH IDENTIFIER-PROPOSED.dwg

(Varies)

Vehicular Signal Head with Identifier

WARNING LIGHTS (TWO)(TYPE A B OR C)-PROPOSED.dwg

(Varies)

Warning Lights (Two)(Type A, B, or C)

Last Updated: March 2010

Page 265

Engineering Department Manual


E/A Design Division CAD Standard

WARNING LIGHTS (TYPE A B OR C)PROPOSED.dwg

(Varies)

Warning Lights (Type A, B, or C)

WORK AREA-PROPOSED.dwg

(Varies)

Work Area

6.24.4.6
Symbol

REGULATORY
Block Name E11-1.DWG Layer Name (Varies) Description Exit Only Sign

KR7-1016a.dwg

(Varies)

No Parking Sing

R1-1.DWG

(Varies)

Stop Sign

R1-2.DWG

(Varies)

Yield Sign

R2-1.DWG

(Varies)

Speed Limit Sign

R2-5a.dwg

(Varies)

Reduced Speed Ahead Sign

R2-5b.dwg

(Varies)

Reduced Speed Sign with Posted Speed

R2-5c.dwg

(Varies)

Speed Zone Ahead Sign

R3-1.DWG

(Varies)

Right Turn Prohibited

R3-2.DWG

(Varies)

Left Turn Prohibited

Last Updated: March 2010

Page 266

Engineering Department Manual


E/A Design Division CAD Standard

R3-3.DWG

(Varies)

No Turns Sign

R3-4.DWG

(Varies)

U-Turn Prohibited Sign

R3-5.DWG

(Varies)

Left Turn Only Ahead

R3-6.DWG

(Varies)

Exit on Left Ahead

R3-7.DWG

(Varies)

Left Lane Must Turn Left Sign Two-Lane Sign for Left Turns and Proceeding Straight

R3-8.DWG

(Varies)

R3-21.DWG

(Varies)

U-Turn Sign

R3-23.DWG

(Varies)

Proceed Straight Only

R3-24.DWG

(Varies)

Right Turn Only Ahead

R3-26.DWG

(Varies)

Exit on Right Ahead

R3-27.DWG

(Varies)

Left or Right Turn Only Ahead

R3-28.DWG

(Varies)

Left or Right Turn, or Proceed Straight, Ahead

R3-32.DWG

(Varies)

Right Lane Must Turn Left Sign

Last Updated: March 2010

Page 267

Engineering Department Manual


E/A Design Division CAD Standard

R3-33.DWG

(Varies)

Thru Traffic Use Left Lane Sign

R3-34.DWG

(Varies)

Thru Traffic Use Center Lane Sign

R3-35.DWG

(Varies)

Thru Traffic Use Right Lane Sign

R4-1.DWG

(Varies)

Do Not Pass Sign

R4-2.DWG

(Varies)

Pass with Care Sign

R4-5.DWG

(Varies)

Trucks Use Right Lane Sign

R4-7.DWG

(Varies)

Keep to Right of Divider

R4-8.DWG

(Varies)

Keep to Left of Divider

R4-9.DWG

(Varies)

Stay in Lane

R5-1.DWG

(Varies)

Do Not Enter Sign

R5-1a.dwg

(Varies)

Wrong Way Sign

R5-2.DWG

(Varies)

Trucks Prohibited

R5-6.DWG

(Varies)

Bicycles Prohibited

Last Updated: March 2010

Page 268

Engineering Department Manual


E/A Design Division CAD Standard

R5-7.DWG

(Varies)

Pedestrian Crosswalk Sign

R5-8.DWG

(Varies)

Sidewalk Closed Sign Sidewalk Closed Alternative Crossing Location (Either Left or Right) Sidewalk Closed Alternative Crossing Location (Left) Sidewalk Closed Alternative Crossing Location (Right) Horizontal One Way to Left Sign

R5-9.DWG

(Varies)

R5-9a.dwg

(Varies)

R5-9b.dwg

(Varies)

R6-1L.DWG

(Varies)

R6-1R.DWG

(Varies)

Horizontal One Way to Right Sign

R6-2L.DWG

(Varies)

Vertical One Way to Left Sign

R6-2R.DWG

(Varies)

Vertical One Way to Right Sign

R7-4.dwg

(Varies)

Standing Prohibited Sign (General Vicinity)

R7-4L.dwg

(Varies)

Standing Prohibited Sign (To Left)

R7-4R.dwg

(Varies)

Standing Prohibited Sign (To Right)

R7-201a.dwg

(Varies)

Tow Away Zone Sign

Last Updated: March 2010

Page 269

Engineering Department Manual


E/A Design Division CAD Standard

R8-3a.dwg

(Varies)

Parking Prohibited Sign

R8-8.dwg

(Varies)

Do Not Stop on Tracks Sign

R9-3a.dwg

(Varies)

Crossing Prohibited Sign

R11-2.DWG

(Varies)

Road Closed Sign

R11-3.DWG

(Varies)

Road Closed Ahead Local Traffic Only Sign

R11-4.DWG

(Varies)

Road Closed to Thru Traffic Sign

R12-2.DWG

(Varies)

Weight Limit 10 Tons Sign

R15-1.DWG

(Varies)

Railroad Crossing

YIELD TO PEDESTRIAN.dwg

(Varies)

Yield to Pedestrian Sign

6.24.4.7
Symbol

REMOVAL
Block Name CANTILEVER SIGN STRUCTURE WITH CHANGEABLE MESSAGE PANELREMOVAL.dwg CANTILEVER SIGN STRUCTURE WITH FIXED MESSAGE-REMOVAL.dwg Layer Name (Varies) Description Cantilever Sign Structure with Changeable Message Panel Cantilever Sign Structure with Fixed Message

(Varies)

CRASH CUSHION ATTENUATORREMOVAL.dwg

(Varies)

Crash Cushion Attenuator

Last Updated: March 2010

Page 270

Engineering Department Manual


E/A Design Division CAD Standard
CURBED TRAFFIC GUIDE SYSTEM POSTS WITH BASE PLATE (WITHOUT C)-REMOVAL.dwg DOUBLE POST MOUNTED SIGN WITH CHANGEABLE MESSAGE PANELPROPOSED.dwg EXISTING SIGN PANEL TO BE RELOCATED-REMOVAL.dwg Curbed Traffic Guide System Posts with Base Plate (Without C) Double Post-Mounted Sign with Changeable Message Panel Fence-Mounted Sign with Fixed Message Panel

(Varies)

(Varies)

(Varies)

FENCE MOUNTED SIGN WITH FIXED MESSAGE PANEL-REMOVAL.dwg GANTRY SIGN STRUCTURE WITH CHANGEABLE MESSAGE PANELSREMOVAL.dwg GANTRY SIGN STRUCTURE WITH FIXED MESSAGE PANELSREMOVAL.dwg PAVEMENT MARKING ARROW SYMBOL (TYPE A-E)-REMOVAL.dwg

(Varies)

Flagger Location

(Varies)

Gantry Sign Structure with Changeable Message Panels Gantry Sign Structure with Fixed Message Panels

(Varies)

(Varies)

Pavement Marking Arrow Symbol (Type A-E)

PAVEMENT MARKING LINEREMOVAL.dwg PEDESTRIAN PUSH BUTTON STANDARD WITH IDENTIFIERREMOVAL.dwg PEDESTRIAN SIGNAL HEAD WITH IDENTIFIER-REMOVAL.dwg POLE MOUNTED BACK TO BACK SIGNS WITH FIXED MESSAGE PANELS-REMOVAL.dwg POLE MOUNTED RIGHT ANGLE SIGNS WITH FIXED MESSAGE PANELSREMOVAL.dwg POLE MOUNTED SIGN WITH FIXED MESSAGE PANEL-REMOVAL.dwg

(Varies)

Pavement Marking Line

(Varies)

Pedestrian Push-Button Standard with Identifier

(Varies)

Pedestrian Signal Head with Identifier Pole-Mounted Back-toBack Signs with Fixed Message Panels Pole Mounted Right-Angle Signs with Fixed Message Panels Pole-Mounted Sign with Fixed Message Panel

(Varies)

(Varies)

(Varies)

Last Updated: March 2010

Page 271

Engineering Department Manual


E/A Design Division CAD Standard

REFLECTORIZED PAVEMENT MARKER-REMOVAL.dwg

(Varies)

Reflectorized Pavement Marker

ROADWAY SURVEILLANCE SENSOR WITH IDENTIFIER-REMOVAL.dwg

(Varies)

Roadway Surveillance Sensor with Identifier

SAND BARREL ARRAY-REMOVAL.dwg

(Varies)

Sand-Barrel Array

SIGN PANEL IDENTIFIERREMOVAL.dwg

(Varies)

Sign Panel Identifier

SIGN STRUCTURE LOCATION IDENTIFIER-REMOVAL.dwg

(Varies)

Sign Structure Location Identifier

SIGNAL CONTROLLER AND CABINET GROUND MOUNTED-REMOVAL.dwg

(Varies)

Signal Controller and Cabinet, Ground-Mounted

SIGNAL CONTROLLER AND CABINET POLE MOUNTED-REMOVAL.dwg

(Varies)

Signal Controller and Cabinet, Pole-Mounted

TRAFFIC GUIDE POSTS-REMOVAL.dwg

(Varies)

Traffic Guide Posts

TRAFFIC POST TOP SIDE OF POLE MOUNTED SIGNAL-REMOVAL.dwg TRAFFIC SIGNAL SPAN WIRE INSTALLATION WITH SPAN LENGTHREMOVAL.dwg TRAFFIC SIGNAL STANDARD WITH IDENTIFIER-REMOVAL.dwg

(Varies)

Traffic Post Top Side of Pole-Mounted Signal Traffic Signal Span Wire Installation with Span Length Traffic Signal Standard with Identifier

(Varies)

(Varies)

TRAFFIC SIGNAL STANDARD WITH MAST ARM LENGTH-REMOVAL.dwg

(Varies)

Traffic Signal Standard with Mast Arm Length

VEHICLE DETECTOR WITH IDENTIFIER-REMOVAL.dwg

(Varies)

Vehicle Detector with Identifier

Last Updated: March 2010

Page 272

Engineering Department Manual


E/A Design Division CAD Standard

VEHICULAR SIGNAL HEAD WITH IDENTIFIER-REMOVAL.dwg

(Varies)

Vehicular Signal Head with Identifier

6.24.4.8
Symbol

WARNING
Block Name KW21-4.DWG Layer Name (Varies) Description Work Area Sign with Input Field

SupPlate.dwg

(Varies)

XXX FEET Sign

W1-1L.DWG

(Varies)

Left Turn Ahead

W1-1R.DWG

(Varies)

Right Turn Ahead

W1-2L.DWG

(Varies)

Left Bend Ahead

W1-2R.DWG

(Varies)

Right Bend Ahead

W1-3L.DWG

(Varies)

Lane Shift to Left Ahead

W1-3R.DWG

(Varies)

Lane Shift to Right Ahead

W1-4aL.dwg

(Varies)

Bear Left Ahead

W1-4aR.dwg

(Varies)

Bear Right Ahead

W1-4bL.dwg

(Varies)

Bear Left Ahead (Two Lanes)

Last Updated: March 2010

Page 273

Engineering Department Manual


E/A Design Division CAD Standard

W1-4bR.dwg

(Varies)

Bear Right Ahead (Two Lanes)

W1-4cL.dwg

(Varies)

Bear Left Ahead (Three Lanes)

W1-4cR.dwg

(Varies)

Bear Right Ahead (Three Lanes)

W1-5L.DWG

(Varies)

Lane Swerves Left

W1-5R.DWG

(Varies)

Lane Swerves Right

W1-6L.DWG

(Varies)

Must Turn Left

W1-6R.DWG

(Varies)

Must Turn Right

W1-7.DWG

(Varies)

Must Turn Either Left or Right

W1-8L.DWG

(Varies)

Left Bend Arrow Sign

W1-8R.DWG

(Varies)

Right Bend Arrow Sign

W2-1.DWG

(Varies)

Four-Way Intersection Sign

W2-2L.DWG

(Varies)

Side Street Intersection on Left Ahead

W2-2R.DWG

(Varies)

Side Street Intersection on Right Ahead

Last Updated: March 2010

Page 274

Engineering Department Manual


E/A Design Division CAD Standard

W2-3L.DWG

(Varies)

Diverging Street Ahead Left

W2-3R.DWG

(Varies)

Diverging Street Ahead Right

W2-4.DWG

(Varies)

Three-Way Intersection

W2-5.DWG

(Varies)

Three-Way Intersection (Diverging)

W2-7-NY.DWG

(Varies)

Converging Street Ahead Left

W2-8-NY.DWG

(Varies)

Converging Street Ahead Left

W2-10-NY.DWG

(Varies)

Alternating Intersections Ahead

W2-11-NY.DWG

(Varies)

Alternating Intersections Ahead

W2-14-NY.DWG

(Varies)

Traffic Circle

W3-1.DWG

(Varies)

Stop Ahead Sign

W3-1a.dwg

(Varies)

Stop Ahead

W3-2.DWG

(Varies)

Yield Ahead Sign

W3-2a.dwg

(Varies)

Yield Ahead

Last Updated: March 2010

Page 275

Engineering Department Manual


E/A Design Division CAD Standard

W3-3.DWG

(Varies)

Traffic Light Ahead

W3-4-NY.DWG

(Varies)

Road Splits Ahead

W3-11-NY.DWG

(Varies)

Road Narrows

W3-14-NY.DWG

(Varies)

Single Lane Sign

W4-1L.DWG

(Varies)

Lane Merges from Left Ahead

W4-1R.DWG

(Varies)

Lane Merges from Right Ahead

W4-2L.DWG

(Varies)

Lanes Merge from Left

W4-2R.DWG

(Varies)

Lanes Merge from Right

W4-3L.DWG

(Varies)

Merging from Left

W4-3R.DWG

(Varies)

Merging from Right

W5-1.DWG

(Varies)

Road Narrows Sign

W5-2.DWG

(Varies)

Narrow Bridge Sign

W5-3.DWG

(Varies)

One Lane Bridge Sign

Last Updated: March 2010

Page 276

Engineering Department Manual


E/A Design Division CAD Standard

W5-4.DWG

(Varies)

Ramp Narrows Sign

W6-1.DWG

(Varies)

Divergence of Lanes

W6-2.DWG

(Varies)

Convergence of Lanes

W6-3.DWG

(Varies)

Two-Way Traffic

W7-1.DWG

(Varies)

Decline

W7-1b.dwg

(Varies)

Decline with Percent Gradation

W8-1.DWG

(Varies)

Bump Sign

W8-2.DWG

(Varies)

Dip Sign

W8-3.DWG

(Varies)

Pavement Ends Sign

W8-4.DWG

(Varies)

Soft Shoulder Sign

W8-5.dwg

(Varies)

Car Swerve Area

W8-6.DWG

(Varies)

Truck Crossing Sign

W8-7.DWG

(Varies)

Loose Gravel Sign

Last Updated: March 2010

Page 277

Engineering Department Manual


E/A Design Division CAD Standard

W8-9.DWG

(Varies)

Low Shoulder Sign

W8-9a.dwg

(Varies)

Uneven Pavement

W9-1L.DWG

(Varies)

Left Lane Ends Sign

W9-1R.DWG

(Varies)

Right Lane Ends Sign

W9-2L.DWG

(Varies)

Lane Ends Merge Left Sign

W9-2R.DWG

(Varies)

Lane Ends Merge Right Sign

W9-3.DWG

(Varies)

Center Lane Closed Sign with Input Field

W10-1.DWG

(Varies)

Railroad Crossing

W10-2.DWG

(Varies)

Railroad Crossing & Adjacent 4-Way Intersection Railroad Crossing & Adjacent 3-Way Intersection Railroad Crossing & Side Street Intersection

W10-3.DWG

(Varies)

W10-4.DWG

(Varies)

W11-1.DWG

(Varies)

Bicycle Area

W11-2.DWG

(Varies)

Pedestrian Crossing

Last Updated: March 2010

Page 278

Engineering Department Manual


E/A Design Division CAD Standard

W11-3.DWG

(Varies)

Deer Area

W11-7.DWG

(Varies)

Horseback Riding Area

W11-9.DWG

(Varies)

Handicapped Zone

W11A-2.DWG

(Varies)

Pedestrian Crossing (Crosswalk)

W12-1.DWG

(Varies)

Road Divides

W12-2.DWG

(Varies)

Vertical Clearance Sign

W13-1.DWG

(Varies)

Speed Limit Sign

W13-2.DWG

(Varies)

Speed Limit at Exit

W13-3.DWG

(Varies)

Speed Limit on Ramp

W14-1.DWG

(Varies)

Dead End Sign

W14-2.DWG

(Varies)

No Outlet Sign

W14-3.DWG

(Varies)

No Passing Zone Sign

W20-1.DWG

(Varies)

Road Work Sign with Input Field

Last Updated: March 2010

Page 279

Engineering Department Manual


E/A Design Division CAD Standard

W20-2.DWG

(Varies)

Detour Sign with Input Field

W20-3.DWG

(Varies)

Road Closed Sign with Input Field

W20-4.DWG

(Varies)

One Lane Road Sign with Input Field

W20-5aL.dwg

(Varies)

Left Two Lanes Closed Sign with Input Field

W20-5aR.dwg

(Varies)

Right Two Lanes Closed Sign with Input Field

W20-5L.DWG

(Varies)

Left Lane Closed Sign with Input Field

W20-5R.DWG

(Varies)

Right Lane Closed Sign with Input Field

W20-7a.dwg

(Varies)

Flagger Ahead

W21-1.DWG

(Varies)

Workers Sign

W21-1a.dwg

(Varies)

Workers Ahead

W21-4.DWG

(Varies)

Road Work Sign

W21-5.DWG

(Varies)

Shoulder Work Sign

W21-5a.dwg

(Varies)

Right Shoulder Closed Sign

Last Updated: March 2010

Page 280

Engineering Department Manual


E/A Design Division CAD Standard

W21-5b.dwg

(Varies)

Right Shoulder Closed Sign with Input Field

Last Updated: March 2010

Page 281

Engineering Department Manual


E/A Design Division CAD Standard

6.25

APPENDIX I COMMON SYMBOLOGY

6.25.1 GRAPHIC SCALE BARS


Symbol Block Name BS1_32in-1ft.dwg BS1_16in-1ft.dwg BS1_2in-1ft.dwg BS1_4 in-1ft.dwg BS1_8in-1ft.dwg BS3_16 in-1ft.dwg BS3_32in-1ft.dwg BS3_4in-1ft.dwg BS3_8in-1ft.dwg BS1-1_2in-1ft.dwg BS1in-1ft.dwg BS1in-10ft.dwg BS1in-100ft.dwg BS1in-20ft.dwg BS1in-200ft.dwg BS1in-25ft.dwg BS3in-1ft.dwg BS1in-30ft.dwg BS1in-40ft.dwg BS1in-400ft.dwg BS1in-5ft.dwg BS1in-50ft.dwg BS1in-500ft.dwg BS1in-60ft.dwg BSFULL.dwg Layer Name D-ANNO-SYMB D-ANNO-SYMB D-ANNO-SYMB D-ANNO-SYMB D-ANNO-SYMB D-ANNO-SYMB D-ANNO-SYMB D-ANNO-SYMB D-ANNO-SYMB D-ANNO-SYMB D-ANNO-SYMB D-ANNO-SYMB D-ANNO-SYMB D-ANNO-SYMB D-ANNO-SYMB D-ANNO-SYMB D-ANNO-SYMB D-ANNO-SYMB D-ANNO-SYMB D-ANNO-SYMB D-ANNO-SYMB D-ANNO-SYMB D-ANNO-SYMB D-ANNO-SYMB D-ANNO-SYMB Description Scale Bar 1/32=1-0 Scale Bar 1/16=1-0 Scale Bar =1-0 Scale Bar =1-0 Scale Bar 1/8=1-0 Scale Bar 3/16=1-0 Scale Bar 3/32=1-0 Scale Bar =1-0 Scale Bar 3/8=1-0 Scale Bar 1-1/2=1-0 Scale Bar 1=1-0 Scale Bar 1=10-0 Scale Bar 1=100-0 Scale Bar 1=20-0 Scale Bar 1=200-0 Scale Bar 1=25-0 Scale Bar 3=1-0 Scale Bar 1=30-0 Scale Bar 1=40-0 Scale Bar 1=400-0 Scale Bar 1=5-0 Scale Bar 1=50-0 Scale Bar 1=500-0 Scale Bar 1=60-0 Scale Bar 1=1

The letter D under the Layer Name is to be replaced by the specific Disciplines Discipline Code.

Last Updated: March 2010

Page 282

Engineering Department Manual


E/A Design Division CAD Standard 6.25.2 NORTH ARROWS
Symbol Block Name Layer Name Description

N_ARROW1.dwg

D-ANNO-SYMB

North Arrow

N_ARROW2.dwg

D-ANNO-SYMB

North Arrow

The letter D under the Layer Name is to be replaced by the specific Disciplines Discipline Code.

Last Updated: March 2010

Page 283

Engineering Department Manual


E/A Design Division CAD Standard

6.26

APPENDIX J CONTRACT BORDERS AND TITLE SHEETS

6.26.1 TITLE SHEET

Last Updated: March 2010

Page 284

Engineering Department Manual


E/A Design Division CAD Standard 6.26.2 TITLE SHEET OVERSIZED (OS)

Last Updated: March 2010

Page 285

Engineering Department Manual


E/A Design Division CAD Standard 6.26.3 TITLE SHEET PATH

Last Updated: March 2010

Page 286

Engineering Department Manual


E/A Design Division CAD Standard

6.26.4 TITLE SHEET PATH OVERSIZED (OS)

Last Updated: March 2010

Page 287

Engineering Department Manual


E/A Design Division CAD Standard 6.26.5 CONTRACT BORDER

Last Updated: March 2010

Page 288

Engineering Department Manual


E/A Design Division CAD Standard 6.26.6 CONTRACT BORDER OVERSIZED (OS)

Last Updated: March 2010

Page 289

Engineering Department Manual


E/A Design Division CAD Standard 6.26.7 CONTRACT BORDER PATH

Last Updated: March 2010

Page 290

Engineering Department Manual


E/A Design Division CAD Standard 6.26.8 CONTRACT BORDER PATH OVERSIZED (OS)

Last Updated: March 2010

Page 291

Engineering Department Manual


E/A Design Division CAD Standard

6.27

APPENDIX K USING STANDARD FORMS ON EOL (INTERNAL USE ONLY)

6.27.1 PID SEARCH The PID Search can be used to find additional information pertaining to a project such as the Contract Number, PID, Title, Charge Code(s) and Facility name by searching based on either the PID, Contract Number or Project Title.

To use this form: 1. Pick the appropriate category that you want to search for, the options are PID, Contract Number or Title. 2. Type in the appropriate search information based on the category you are searching in. 3. Select Submit Once the query is finished a list of all projects matching your criteria will be displayed with the following information Contract Number, PID, Title, Charge Code and Facility Name.

Last Updated: March 2010

Page 292

Engineering Department Manual


E/A Design Division CAD Standard 6.27.2 REQUEST PROJECT ARCHIVAL This form is used to request that a project be archived from the Project M: drive to the Archive N: drive in order to preserve a contract sets files at a particular milestone. Please ensure that all disciplines involved place the appropriate folders within the appropriate Submittals folder for their discipline prior to requesting the Project Archival.

To use this form: 1. Requested By: Either the LEA or the Task Leader may request for an Archival. 2. Email: It is mandatory that you supply a valid email address to receive a confirmation of your request. This email will also be used to notify you as soon as the request has been processed. 3. Discipline: Pick which Discipline you belong to. 4. Upload to Livelink: Check this box if you would like files uploaded to a project website on Livelink. 5. Stage: Enter what stage the project is in, I, II, III or IV. Last Updated: March 2010 Page 293

Engineering Department Manual


E/A Design Division CAD Standard 6. Type: Enter the type of submittal this is, PA Review, As-Advertised, 50% Submittal, etc 7. Number: Fill this out only if your project is either a PACC or an Addendum. 8. Facility: Enter the facility the project is for. 9. PID: Enter the PID of the project 10. Folder Path: Provide the path to the folder that needs to be archived. 11. Disciplines: Check all the disciplines involved in this project. This will ensure that all the involved disciplines folders are archived.

Last Updated: March 2010

Page 294

Engineering Department Manual


E/A Design Division CAD Standard 6.27.3 REQUEST PROJECT CAD DRAWINGS This Section Currently Under Construction

Last Updated: March 2010

Page 295

Engineering Department Manual


E/A Design Division CAD Standard 6.27.4 REQUEST MANDATORY CAD STANDARDS REVIEW

Last Updated: March 2010

Page 296

Engineering Department Manual


E/A Design Division CAD Standard 1. Type of Review: Pick the type of Review ( Interim or PA Wide Review) 2. LEA: Only the LEA may request for a Mandatory CAD Review. It is important to provide the name of the LEA for the results of the CAD Review. 3. Email: It is mandatory that you provide a valid email address to receive a confirmation of your request. This email will also be used to notify you as soon as the request has been processed. 4. Discipline: Enter the discipline that the LEA belongs to. 5. Facility Name: Enter the facility the project is for. 6. Charge Code: Enter the Charge Code to be used by the CAD Support Group for CAD Standards Review. 7. PID: Enter the PID of the project. 8. Pre-mylar Date: Provide the Pre-mylar date of the project. 9. Contract Engineer: Provide the name of the Contract Engineer that is to be notified once the DWF files have been uploaded to Livelink for PA Wide Review. 10. Disciplines/Taskleaders/Consultant name: Check all the disciplines involved in this project. This will ensure that all the involved disciplines drawings are reviewed. Please ensure that all disciplines place their drawings in their appropriate submittal folders. It is important that the names of the Task leaders are provided in order to provide them with the results of the CAD Standards review. If a consultant has prepared the drawings for a particular discipline the consultant company name must also be provided because the requirements of CAD Standards compliance are slightly different for consultants.

Last Updated: March 2010

Page 297

Engineering Department Manual


E/A Design Division CAD Standard 6.27.5 REQUEST NON-MANDATORY CAD STANDARDS REVIEW

Last Updated: March 2010

Page 298

Engineering Department Manual


E/A Design Division CAD Standard 1. Requested By: Either the LEA or Task Leader may request for a Non-Mandatory CAD Review. 2. LEA: It is important to provide the name of the LEA for the results of the CAD Review. 3. Email: It is mandatory that you provide a valid email address to receive a confirmation of your request. This email will also be used to notify you as soon as the request has been processed. 4. Discipline: Enter the discipline that the requestor belongs to. 5. Stage: Enter what stage the project is in, I, II, III or IV. 6. Type: Enter the type of submittal this is, PA Review, As-Advertised, 50% Submittal, etc 7. Number: Fill this out only if your project is either a PACC or an Addendum. 8. Facility: Enter the facility the project is for. 9. PID: Enter the PID of the project 10. Charge Code: Enter the Charge Code to be used by the CAD Support Group for CAD Standards Review. 11. Folder Path: Provide the path to the folder that needs to be reviewed. 12. Upload to Livelink: Check this box if you would like files uploaded to a project website on Livelink. 13. Disciplines/Taskleaders/Consultant name: Check all the disciplines involved in this project. This will ensure that all the involved disciplines drawings are reviewed. Please ensure that all disciplines place their drawings in their appropriate submittal folders. It is important that the names of the Task leaders are provided in order to provide them with the results of the CAD Standards review. If a consultant has prepared the drawings for a particular discipline the consultant company name must also be provided because the requirements of CAD Standards compliance are slightly different for consultants.

Last Updated: March 2010

Page 299

Engineering Department Manual


E/A Design Division CAD Standard 6.27.6 REQUEST WORK ORDER CAD REVIEW

Last Updated: March 2010

Page 300

Engineering Department Manual


E/A Design Division CAD Standard 1. LEA: Only the LEA may request for a Work Order CAD Review. It is important to provide the name of the LEA for the results of the CAD Review. 2. Email: It is mandatory that you provide a valid email address to receive a confirmation of your request. This email will also be used to notify you as soon as the request has been processed. 3. Discipline: Enter the discipline that the LEA belongs to. 4. Charge Code: Enter the Charge Code to be used by the CAD Support Group for CAD Standards Review. 5. PID: Enter the PID of the project. 6. Facility Name: Enter the facility the project is for. 12. Folder Path: Provide the path to the folder that needs to be reviewed. 14. Disciplines/Taskleaders/Consultant name: Check all the disciplines involved in this project. This will ensure that all the involved disciplines drawings are reviewed. Please ensure that all disciplines place their drawings in their appropriate submittal folders. It is important that the names of the Task leaders are provided in order to provide them with the results of the CAD Standards review. If a consultant has prepared the drawings for a particular discipline the consultant company name must also be provided because the requirements of CAD Standards compliance are slightly different for consultants.

Last Updated: March 2010

Page 301

Engineering Department Manual


E/A Design Division CAD Standard 6.27.7 REQUEST PROJECT FOLDER STRUCTURE

Last Updated: March 2010

Page 302

Engineering Department Manual


E/A Design Division CAD Standard

6.28

APPENDIX L REQUEST TO CHANGE STANDARD

Last Updated: March 2010

Page 303

Engineering Department Manual


E/A Design Division CAD Standard

6.29

CAD STANDARD UPDATES AND REVISIONS

6.29.1 2010 Q1

Last Updated: March 2010

Page 304

Potrebbero piacerti anche