Sei sulla pagina 1di 6

IRCON International Limited

(A Govt. Of India Undertaking)


Qazigund-Baramulla New Rail Line Project, Srinagar
SUB CONTRACTORS RUNNING ACCOUNT BILL/CC
RA Bill/CC No.2nd Date: 31-05-2008
Name of work: Construction of FOBs At Anantnag Station Yards (Package FOB-1RA)
on Qazigund - Baramulla Section of New BG Rail Line Project (J&K)
Name of Contractor: M/S Royal Steel, (JV), Industrial Estate, Baghi Ali, Mardan Khan, Srinagar-190 011.
Contract agreement / work Order No.IRCON/ J&K -SGR/ 1008/ Foot Over Bridges/ FOB-1RA/LT/423/18867 Date: 29-03-2008
Contract Value: Rs. 75,81,983.70
Date of commencement of Work: 29-03-2008
Date of completion of work: Scheduled: 28-05-2008 Time extension on process
Date of Measurement:31-05-2008 MB NO:1239

BOQ Qty executed Qty executed Qty executed Rate Amount upto Amount upto last Amount since
Sl no Description of Item Unit BOQ Qty.
Item upto this bill upto last bill since last bill (in Rs.) this bill bill last bill

SCHEDULE A: DSR 2002 Items, Quoted rete 85% Above


SUB HEAD NO-1: EARTH WORK
Earth work in excavation in over
areas (exceeding 30 CM in
depth,1.5m in widthas 10 sqm on
A.1 plan) including disposal of excavated
earth, lead upto 50m and lift upto
1.5m disposed earth to be levelled
and neatly dressed.
1 A.1.1 in all kinds of soil cum 322 481.268 481.268 - 91.50 44,036.02 44,036.02 -
Earth work in excavation in
foundation trenches or drains (not
exceeding 1.5m in witdth or 10 sqm in
plan) including dressing of sides and
A.2
ramming of bottoms, lift upto 1.5m,
including getting out the excavated
soil and disposal of surplus
excavated soil
2 A.2.1 in all kinds of soils cum 286 - - - 93.55 - - -
Filling available excavated
earth(excluding rock) in trenches ,
plinth, sides of foundations etc. in
3 A.3 layers not exceeding 20 cm in depth, cum 486.5 - - - 30.25 - - -
consolidating each deposited layer by
ramming and watering, lead upto 50m
and and lift upto 1.5m.
Centering and shuttering including
A.4 strutting, propping etc. and removal of
form for
Foundations , footings bases of
4 A.4.1 sqm 108.75 84.84 84.84 - 61.10 5,183.72 5,183.72 -
columns etc. for mass concrete.
Suspended floors, roofs, landings,
5 A.4.2 sqm 157.5 - - - 112.20 - - -
balconies and access platform.

K:\Bill FOB-1RA April 2008.xls Page 1 of 6


Lintels, beams, plinth beams, girders,
6 A.4.3 sqm 98 - - - 87.95 - - -
bressumers and cantilevers.
Columns, pillars, piers,abutments,
7 A.4.4 sqm 191 - - - 135.80 - - -
posts and struts.
Stairs, (excluding landings)except
8 A.4.5 sqm 177.75 - - - 106.40 - - -
spiral staircases.
Edges of slabs and breaks in floors
A.4.6
and walls.
9 A.4.6.1 under 20 cm wide. meter 90 - - - 29.90 - - -
Extra for additional height in
centering, shuttering where ever
required with adequate bracing,
propping etc. including cost of
A.5
deshuttering and decentering at all
levels, over a height of 3.5m for every
additional height of 1 m or part
thereof (plan area
Suspended floors roofs landings
10 A.5.1 beams and balconies (plan area to be sqm 380.25 - - - 45.90 - - -
measured)
Providing and laying in position
cement concrete of specified grade
A.6
excluding the cost of centering and
shuttering . All work upto plinth level.
1:4:8 (1cement:4Coarse sand:8
11 A.6.1 graded stone aggregate 40mmm cum 13 18.512 18.512 - 1,404.70 26,003.81 26,003.81 -
nominal size)
Providing and laying in position
machine batched machine mixed and
machine vibrateddesign mix cement
concrete of specified grade for
reinforced cement concrete structural
element, excluding the cost of
centering, shuttering, finishing and
reinforcement in
All work upto plinth level/ platform
12 A.7.1 cum 107.75 84.70 84.70 - 2,284.05 193,459.04 193,459.04 -
level
A.7.2 All work from plinth level to all height
Beams, plinth beams, girders,
brussumers,, cantilevers, suspended
13 A.7.2.1 cum 43.75 - - - 2,518.25 - - -
floors, lintels, roofs and staircases
including spiral staircases, shelves
Add or deduct for providing richer or
A.8 leaner mixes respectively at all floor
levels.
Providing M35 grade RCC instead of
14 A.8.1 cum 151.5 84.70 84.70 - 140.00 11,858.00 11,858.00 -
M20 grade RCC
TOTAL OF SCHEDULE A : 280540.59 280540.59 0.00
185% OF SCHEDULE A : Quoted
519000.09 519000.09 0.00
Rate 45% Above

K:\Bill FOB-1RA April 2008.xls Page 2 of 6


SCHEDULE B : Quoted rete 53.50% Above - - -
STEEL ITEM-NON DSR - - -
Providing, cutting,
straightening,hooking,bending,placing
and bindingin position cold twisted
reinforcement of TMT steel bars for
15 B.1 kg 17246.25 11,408.284 9,950.000 1,458.284 40.60 463,176.33 403,970.00 59,206.33
RCC work or as temperature
reinforcement where ever required as
per approved drawings including
binding wires and all lead an

NOTE: payment for above shall be


made only for quantity of
reinforcement actually used as per
approved drawings excluding all
wastages.
Structural steel works with different
types/sections of steel in stair case
and stagings of stair cases and foot
16 B.2 over bridge at all heights including kg 22822 4,259.40 - 4,259.40 50.00 212,970.00 - 212,970.00
cutting, hoisting fixing in position and
applying a priming coat of approved
steel primer and painting tw

Structural steel works with different


types/sections of steel for main foot
over bridge (excluding stagings,
17 B.3 staircases and roof trusses) including kg 19477 18,732.60 - 18,732.60 56.80 1,064,011.68 - 1,064,011.68
cutting, hoisting fixing in position and
applying a priming coat of approved
steel primer and painting two

Structural steel works with different


types/sections of steel in trusses for
roof coveringof stair case and main
18 B.4 FOB including cutting, hoisting fixing kg 8091 - - - 47.70 - - -
in position and applying a priming
coat of approved steel primer and
painting two or more coats of synt
Providing and fixing MS round
holding down bolts with nuts and
washers plates complete with all
contractors material, labour, toolsand
19 B.5 kg 368 - - - 52.40 - - -
plants,lead and lift, as per approved
detailed dtrawingsas per
specifications and as directed by
Engineer-in-charge.

Structural steel works with different


types/sections of steel including
cutting, hoisting fixing in position and
B.6 applying a priming coat of approved
steel primer and painting two or more
coats of synthetic enamel paint on
new works, complete job(synthetic

in gratings, frames, guard bars,


20 B.6.1 ladders, railings, brackets, gates and kg 2510.5 - - - 54.70 - - -
similar works.

K:\Bill FOB-1RA April 2008.xls Page 3 of 6


Providind and fixing MS angle
65x65x8mm to act as nosing welded
with main members of stair case and
drilling through angles and tiles and
21 B.7 kg 4296 - - - 53.40 - - -
bolting at two or more places
including necessary welding and
applying a priming coat of approved
primer on exposed s
Providing and fixing hard drawn steel
wire fabric 75x25mm mesh of weight
not less than 7.75 kg/sqm to sides of
FOB including welding to angle iron
22 B.8 sqm 175.5 - - - 465.30 - - -
frame, applying a priming coat of
approved steel primer and painting
two or more coats of synthetic
enamel p
TOTAL OF SCHEDULE B : 1740158.01 403970.00 1336188.01
153.50% OF SCHEDULE B : Quoted
2671142.55 620093.95 2051048.60
Rate 53.50% Above
SCHEDULE C : Quoted rete 25% Above
Providing and fixing
TRACKDEK/CRIL or equivalent hi rib
profiled sheeting 1000-1020mm
cover width 28-30mm high crest @
23 C.1 250-255mm c/c, manufactured out of sqm 432 - - - 649.00 - - -
0.50mm thick TCT (total coated
thickness) hi-tensile prepainted
galvelume steel (coating class AZ-
150

the male end of sheet shall have anti


capillary flute in side lap to prevent
leakages. The sheet shall be fixed by
means of galvanised self drilling, self
tapping fasteners( 12-14x55 with
EPDM seats). The sheet shall be
supplied in lengths maximum upto 6-

Note: payment shall be made on


finished area. No overlap shall be
paid.

Supply of ridges for 301-500mm girth,


manufactured out of same material
as mentioned above in item No. C.1
24 C.2 including fixing complete job with all meter 67.75 - - - 385.00 - - -
contractors material, labour, tools and
plants,lead and lift as per approved
detailed drawings, as per specif

Providing and laying 50mm thick non


shrink grout as per specifications with
all contractors material, labour, tools
25 C.3 and plant,lead and lift, as per sqm 12 - - - 1,450.00 - - -
approved detailed drawings, asper
specifcations and as directed by
Engineer-in-cahrge.

K:\Bill FOB-1RA April 2008.xls Page 4 of 6


supplying and fixing 25mm thick high
strength Chequered precast cement
concrete tiles, made out of minimum
26 C.4 M40 grade concret, and mixed with sqm 228.75 - - - 848.60 - - -
approved shade and quality synthetic,
inorganic,UV stabilised and colourfast
pigments to get the properties of low

Note: The work shall be done as per


specifications of IS 13801:1998 (with
upto date ammendments)

supplying and fixing 22mm thick high


strength Chequered precast cement
concrete tiles, made out of minimum
27 C.5 M40 grade concret, and mixed with sqm 41 - - - 848.60 - - -
approved shade and quality synthetic,
inorganic,UV stabilised and colourfast
pigments to get the properties of low

Note: The work shall be done as per


specifications of IS 13801:1998 (with
upto date ammendments)
Providing and fixing PVC moulding on
50mm wide flat of railing with all
contractors material, labour toolsand
28 C.6 plants, lead and lift, as per approved meter 124.5 - - - 74.80 - - -
detailed drawings, asper
specifications and as directed by
Engineer-in-charge.
TOTAL OF SCHEDULE C : 0.00 0.00 0.00
125% OF SCHEDULE C : Quoted
0.00 0.00 0.00
Rate 25% Above
Grand Total: (A+B+C)= 3,190,142.63 1,139,094.04 2,051,048.60
Say : 2,051,049.00

CHECK LIST

K:\Bill FOB-1RA April 2008.xls Page 5 of 6


Certified that the foregoing claim is correct, for which necessary measurement were taken and recorded at the MB-1239 by sh.
Surajit Ghosh, AM/Civil, dated 31-05-2008and that the work has been satisfactorily as per drawing and specification.

Date: JGM/ Civil


Certified that,
1 Measurements Recorded in MB No. 1239 are fully accepted by me and I do not have any other claim against this bill.

2 The labour employed by me have been paid minimum wages as fixed in similar type of work in the area.

All taxes including Royalty charges. Cess, etc. due to the govt. on the materials used for this work have been fully paid and
3
no payment is due to them.

4 All the insurance polices as per previous of the contract has been taken by me and are valid as on date.

I have extended the provident fund benefits to the staff engaged by me and requisites amount of providend fund has been
5
remitted to the providend fund commissioner.

6 The statury formalities and guidelines has been complied with.

Date: Contractor

Certified that,

1 The quantity billed is not more than the quantity actually executed at site.

No material has been issued to the contractor, for which the cost was to be recovered except such as specially provided in
2
the agreement/ work order.

No departmental tools & plants have been issued to the contractor other than those for which hire charges have been
3
recovered in this bill.

4 In case of lump sum payment, approximate quantity billed is not more than the quantity actually at site.

5 The work has been executed as per approved drawing and specifications and the method of measurement is correct.

6 That the statury formalities and guidelines has been complied with.

AM/C DGM/ Civil

Chargeble to ........................................................................ and to be included in the account for the month of ...................
To be paid at …………................... in presence of ............................................................. by Cheque on or before................

Date: Manager/Finance