Integrated Access Controller Installation Manual

Quality Assurance

Technical Innovation

45

Sincere and Faithful Human-centered Design

3000

LED

1 4 7

2 5 8 0

3 6 9 #

ANSON Technology Co., Ltd

Product Manual Installation Manual

Product Connection

Function Debugging

Product Maintenance

Live Safely and Conveniently

Product Manual
Product Series

Anson Integrated Access Control Series: ASI-8910, ASI-8920, ASI-8930

ASI-8910 ASI-8920
Features

ASI-8930

Anson Integrated Access Control is characterized by its elegant design and convenient application and installation, which is especially suitable for office buildings and shops. The device is equipped with built-in reader and can work both as controller and reader.
Operation Instruction

Anson Integrated Access control should be installed indoor. Please consider water- proof facility in case outdoor application is needed.
Notice

For detailed information, please refer to Product Manual and Wiring Diagram. Please make sure installation is correctly completed before turn on the power. When connect any external device, please turn off the power. This manual is only a general instruction and all products mentioned in this manual are Anson products.

The exterior design of ASI-8920\ 8930 is protected and patented in P. R. China.

Live Safely and Conveniently

Product Manual
ASI-8910 ASI-8910

Product Size

ASI-8910

117
The Front The Back

117

21 The Side

Product Parameters
Working Voltage: DC9-15V Working Current:70mA Unlock Current: 3000mA Reading Distance: 3-10cm Card Type: ID card W orking Temperature: -15~55 Card Capacity: 800pcs Input Interface: 1pcs exit button, 1pcs door magnet Output Interface: 1pcs lock control port(normal open, normal close)

Live Safely and Conveniently

Installatioin Manual
ASI-8910 ASI-8910
Fixing Hole Rubber Plug

Self-trapping Screw

Wire Hole

Rear Cover

1. Uncover the back from the bottom

2. Put the back cover against wall and screw tight the bolts

3. Ensure power cable is ready before put the system on,

4. Screw bolt from bottom

Live Safely and Conveniently

Product Connection
ASI-8910 ASI-8910
ASI-8 9 1 0 Interface

GND +12V COM NO

NC

GND SW BELL BELL

Power

EM Lock

Exit Button

Door Bell

ASI-8910 Interface ASI-8910 Interface


GND +12V COM NO NC GND SW BELL BELL GND +12V COM NO NC GND SW BELL BELL

Power Interface

GND

+12V

Power Interface

GND

+12V

V+ VNO COM NC

Fail- safe Connect with Power ASI-8910 Interface Connect with EM Lock ASI-8910 Interface

+
Fail-secure

GND +12V COM NO

NC

GND SW BELL BELL

GND +12V COM NO

NC GND SW BELL BELL

Power Interface

Electric Bolt
GND

+12V
GND
+12V Red GND Black SIGNAL SIGNAL

+12V

Power Interface

Iron Core Cover Plate Door Magnet Connect with Electric Lock Connect with Electric Bolt

Live Safely and Conveniently

Product Connection
ASI-8910 ASI-8910
ASI-8910 Interface ASI-8910 Interface

GND +12V COM NO

NC

GND SW BELL BELL

GND +12V COM NO

NC

GND SW BELL BELL

Automatic Door Interface ( Switch Signal)

Barrier Interface (Electric Level Signal)

Common end Stop Close Open

COM1

Connect with Barrier

For this type of connection, the barrier switch is closed in normal status. When user presents card or presses the exit button, the barrier will be opened, The opening time depends on the door-open delay time. It is recommended to install ultra-red and ground sensor for protection.

COM2

The automatic door is open when COM1-COM2 is short circuit.

Connect with Automatic Door ASI-8910 Interface

ASI-8910 Interface

GND +12V COM NO

NC

GND SW BELL BELL

GND +12V COM NO

NC

GND SW BELL BELL

Exit Button Active Boorbell

Connect with Door Bell

Notice: Definition of product interface should be in accordance with the real product. For any inconsistence, please contact with us..
Live Safely and Conveniently

Function Debugging
ASI-8910 ASI-8910
Test Reading Card
Invalid Card: If the reader sounds twice after the card is presented to the reading area for one second, the card is invalid. Valid Card: If after the card is presented to the reading area for 0.5 seconds, the reader sounds once, green lights on and delay acts, then the card is valid.

3 - 10CM

CA

RD

ASI-8910

Test the Keypad


Dial * Input the administrator password MODE light is on, program mode

Read card

Input 4-digit card serial number

Dial 2 add one card

Dial # to exit from programming mode

Complete the setting

Test Output
ASI-8910 Interface
GND +12V COM NO NC GND SW BELL BELL

, When the power is on, Adjust the multimeter to in normal state, COM-NC is short circuit, while COMNO is open circuit. When present the valid card or press the exit button, COM-NC turns into open circuit.

NC COM NO
Normal State

NC COM NO
Door-open State

Test Input
As shown in the picture, when the button is pressed, the device sounds once and the relay status changes once.
GND +12V COM NO NC GND SW BELL BELL

Live Safely and Conveniently

Product Maintenance
ASI-8910 ASI-8910

Common Question
1. If there is no sound when card is presented to the reading area, the reading function maybe damaged. 2. If there is no sound when press the keys, the keypad maybe damaged. 3. When add card, if the device exits program mode automatically, the memory maybe damaged. 4. If valid card is read and OK light is on, while relay does not act, the lock control may malfunction. 5. If relay keeps on in open state, buzzer keeps buzzing, and SW-GND is short or lower than 3.5V , the keys maybe damaged. 6. MenCi-GND is short or lower than 3.5V, the door magnet input maybe damaged. 7. Voltage of DATA0, DATA1 and GND should be higher than 3.5V, otherwise exterior reader can not work properly. 8. When RS485 is applied, voltage between 485+ and 485- is around 5 voltages. The life of products is related to application environment and application method. Please carefully follow the product manual and installation manual. In case of any problem, please contact with our technical support instead of self- repairment. Please keep the original state of the products when sending back for repairment. Please notify us if you have any special demand, and we will feedback within 48 hours.

Live Safely and Conveniently

Product Manual
ASI-8920 ASI-8920

150mm

Fixing Hole

30mm

Fixing Hole

88mm

Jumper
RX GND 12V 485 232 TX GND DAT0 485+ DAT1 485SW GND 2C 2NO MenC1 GND 1NO 1C BELL 1NC BELL

1 4 7

2 5 8 0

3 6 9 #

Fixing Hole

The Front

The Back

The Side

Product Parameters
Working Voltage:DC9-15V Static Current:110mA Reading Distance: 5-10cm Card Type: ID card Working Temperature: -15~55 Card Capacity: 3000pcs Input Interface: 1pcs exit button, 1pcs door magnet Output Interface: 1pcs lock control port (normal open, normal close), 1pcs door magnet alarm output port (normal close) Communication Mode:RS232/RS485 Reader Interface: Wiegand 26

Installation Manual
ASI-8920 ASI-8920

1. Remove the two keys first.

2. Unfasten the two screws.

Push up the back cover to open

First open the lower part of backcover for around 1cm. Please note that open too wide may lead to damage to the device.

3. Open the back cover and connect the device according to the wiring diagram.

4. Fix the backcover on the wall Reassemble the device. (according to 1, 2 and 3 in reversed order.

Live Safely and Conveniently

Product Connection
ASI-8920 Interface
Power Interface GND 12V Reader Interface Exit Button Interface
RX GND 12V 485 232 TX GND DAT0 485+ DAT1 485SW GND 2C 2NO MenC1 GND 1NO 1C BELL 1NC BELL

ASI-8920 ASI-8920

RX 485 232 TX GND 485+ 4852C 2NO 1NO 1C 1NC Lock Control Interface RS485 Interface RS232 Interface

DAT0 DAT1 SW GND

Door Magnet Interface Door bell Interface

MenC1 GND BELL BELL

Door Magnet Alarm Output Interface

* Valid statedoor magnet is normal open.

Power Interface

ASI-8 9 2 0 Interface

GND 12V DAT0 DAT1 SW GND MenC1 GND BELL BELL

GND

+12V

GND 12V DAT0 DAT1 SW GND MenC1 GND BELL BELL

RX TX GND 485+ 4852C 2NO 1NO 1C 1NC

GND

+12V

ASI-8 9 20 Interface

RX TX GND 485+ 4852C 2NO 1NO 1C 1NC

Power Interface

V+ VNO COM NC

Fail-safe Connect with EM Lock

Connect with Power


GND 12V DAT0 DAT1 SW GND MenC1 GND BELL BELL

+
Fail-secure

GND 12V DAT0 DAT1 SW GND MenC1 GND BELL BELL

ASI-8920 Interface
RX TX GND 485+ 4852C 2NO 1NO 1C 1NC
+12V

ASI-8920 Interface
RX TX GND 485+ 4852C 2NO 1NO 1C 1NC

Power Interface

Electric Bolt
GND

+12V
GND

+12V GND SIGNAL SIGNAL

Door Magnet Connect with Electric Lock Power Interface Iron Core Cover Plate

* Valid statedoor magnet is normal open.

Connect with Electric Bolt

Live Safely and Conveniently

Product Connection
ASI-8920 ASI-8920

Barrier Interface (Electric Level Signal)

Common end Stop Close Open

For this type of connection, the barrier switch is closed in normal status. When user presents card or presses the exit button, the barrier will be opened, The opening time depends on the door-open delay time. It is recommended to install ultra-red and ground sensor for protection.

Automatic Door Interface ( Switch Signal)

GND 12V DAT0 DAT1 SW GND MenC1 GND BELL BELL

GND 12V DAT0 DAT1 SW GND MenC1 GND BELL BELL

ASI-8920 Interface
RX TX GND 485+ 4852C 2NO 1NO 1C 1NC
COM1 COM2

ASI-8920 Interface
RX TX GND 485+ 4852C 2NO 1NO 1C 1NC
The automatic door is open when COM1-COM2 is short circuit.

Connect with Barrier

Connect with Automatic Door

GND 12V DAT0 DAT1 SW GND MenC1 GND BELL BELL

GND 12V DAT0 DAT1 SW GND MenC1 GND BELL BELL

ASI-8920 Interface

ASI-8920 Interface

RX TX GND 485+ 4852C 2NO 1NO 1C 1NC

RX TX GND 485+ 4852C 2NO 1NO 1C 1NC

Exit Button
Active Boorbell Connect with Door Bell

ASI-8920 Interface
RX TX GND 485+ 4852C 2NO 1NO 1C 1NC

GND 12V DAT0 DAT1 SW GND MenC1 GND BELL BELL

Alarm Light

ASI-8920 Interface
RX TX GND 485+ 4852C 2NO 1NO 1C 1NC
Black Red Green White

GND 12V DAT0 DAT1 SW GND MenC1 GND BELL BELL

+
GND

1 4 7 *
+12V

2 5 8 0

3 6 9 #
2620

Connect with Alarm Device

Power Interface

Connect with Reader

Live Safely and Conveniently

Product Connection
ASI-8920 ASI-8920

RX GND 12V 485 232 TX GND DAT0 485+ DAT1 485SW GND 2C 2NO MenC1 GND GND 1NO 1C BELL 1NC BELL
ASI-8920 Interface

Converter

Connect with RS485


Rs232

PWD RxD TxD

RS485-RS232 Convertor

RS485
Rs485

RS232

T/R+ T/RGND

Computer Interface

RS485

485485+

Computer Interface For 485 communication, please follow the diagram for connection and no other connection mode should be used. DB9-Hole
12345

RS232
Connect with PC or Router
232 485 DC9~30V

RS485\TCP/IP

RX RX GND GND 12V 485 232 TX GND GND DAT0 DAT0 485+ DAT1 485485SW SW GND 2C 2NO 2NO MenC1 MenC1 GND GND 1NO 1C 1C BELL BELL 1NC BELL
ASI-8920 Interface Connect with PC or Router
232 485 DC9~30V Rs232

DB9-Hole
12345

Rs232

ASV-TCP/IP

9~30V+ 9~30V485+ 485Rj45 Rs485

RX GND TX 12V 12V 485 232 TX GND DAT0 485+ 485+ DAT1 DAT1 485SW GND GND 2C 2C 2NO MenC1 GND 1NO 1NO 1C BELL 1NC 1NC BELL BELL
ASI-8920 Interface

RS232\TCP/IP

ASV-TCP/IP

9~30V+ 9~30V485+ 485Rj45 Rs485

RX GND TX 12V 12V 485 232 TX GND DAT0 485+ 485+ DAT1 DAT1 485SW GND GND 2C 2C 2NO MenC1 GND 1NO 1NO 1C BELL 1NC 1NC BELL BELL
ASI-8920 Interface

Live Safely and Conveniently

Function Debugging
ASI-8920 ASI-8920
Test Reading Card

Invalid Card: If the reader sounds twice after the card is presented to the reading area for one second, the card is invalid. Valid Card: If after the card is presented to the reading area for 0.5 seconds, the reader sounds once, green lights on and delay acts, then the card is valid.

Test the Keypad


When the buzzer sounds once Dial *, the orange light flashes; Input000000, the orange light turns on and device enters program mode. This means the keypad is OK.
1 4 7 2 5 8 0 3 6 9 #

Test Output
Adjust the multimeter to , When the power is on, in normal state, 1C-1NC is short circuit, while 1 C-1NO is open circuit. When present the valid card or press the exit button, 1C-1NC turns into open circuit, while 1C1NO is short circuit.
GND 12V DAT0 DAT1 SW GND MenC1 GND BELL BELL
ASI-8920 Interface

RX TX GND 485+ 4852C 2NO 1NO 1C 1NC

1NC 1C 1NO
A

1NC 1C 1NO
Door-open State

Normal State

Test Input
If valid default input is normal open, no input available for the device when input signal is open-circuit; while input available when input signal is close-circuit. The status reversed when valid default input is normal close. The user can decide the type of default input setup in the software. 8920 has two input interfaces: SW-GND is button input; MenCi-GND is door magnet input. Both of them can be changed in channel setup.

GND 12V DAT0 DAT1 SW GND MenC1 GND BELL BELL


ASI-8920 Interface

RX TX GND 485+ 4852C 2NO 1NO 1C 1NC

Live Safely and Conveniently

Function Debugging
ASI-8920 ASI-8920
Connect with Exterior Identification Device
1. Select the device 3. Get the card number

After the exterior device is connected with ASI-8920, please select Tools---Card Register in the software program. Then, select the exterior device and start to read the card. If you can find the card number in the list, it means the exterior device works correctly.

2.Start to read card

Setup the Jumper

Test the Communication


ASI-892 has two kinds of communication modes: RS232 and Rs485. User can chose the communication mode by setting up the jumper. ASI-8920 can connect with PC serial port, and one serial port only connects with one ASI-8920. RS485 signal should be converted to Rs232 signal before it can communicate with PC. RS485 can connect with multiple devices. After ASI-8920 is connected with PC, user can detect ASI-8920 address by detecting serial port (please refer to the user manual to setup the address). Ifconnected is displayed, the communication is ok. User can get version and model number of ASI-8920 by inputting the address and clicking Auto Detect.

Rs485

Rs232

Test the time of ASI-8920


Time adjustment is shown in the picture on the left. The time of controller should be in consistent with PC. User can get updated time for controller by pressRefresh. If controller time is incorrect, card record may get lost, validity of cardread is in doubt, and moreover, valid card may turn into be invalid.

* otherwise

PC time should be in consistent with controller time; the reader may not work properly.

Live Safely and Conveniently

Product Maintenance Common Question


1. If there is no sound when card is presented to the reading area, the reading function maybe damaged. 2. If there is no sound when press the keys, the keypad maybe damaged. 3. When add card, if the device exits program mode automatically, the memory maybe damaged. 4. If valid card is read and OK light is on, while relay does not act, the lock control may malfunction. 5. If relay keeps on in open state, buzzer keeps buzzing, and SW-GND is short or lower than 3.5V , the keys maybe damaged. 6. MenCi-GND is short or lower than 3.5V, the door magnet input maybe damaged. 7. Voltage of DATA0, DATA1 and GND should be higher than 3.5V, otherwise exterior reader can not work properly. 8. When RS485 is applied, voltage between 485+ and 485- is around 5 voltages. The life of products is related to application environment and application method. Please carefully follow the product manual and installation manual. In case of any problem, please contact with our technical support instead of self-repairment. Please keep the original state of the products when sending back for repairment. Please notify us if you have any special demand, and we will feedback within 48 hours.

ASI-8920 ASI-8920

Urgent Maintenance 1. When the exterior reader can not read the cards, please test the voltage of DATA0GND and DATA1---GND. If the voltage is less than 3.5V, please weld TVS2, TVS3. 2. When door magnet input fails, please test the voltage between Menci and GND. If the voltage is less than 3.5V, please weld TVS5. 3. When exit button input fails, please test the voltage between SW and GND. If the voltage is less than 3.5V, please weld TVS4.

PCB

Live Safely and Conveniently

Product Manual
ASI-8930 ASI-8930

150mm

Fixing Hole

30mm

Fixing Hole

88m m

Jumper
RX GND 12V 485 232 TX GND DAT0 485+ DAT1 485SW GND 2C 2NO MenC1 GND 1NO 1C BELL 1NC BELL

1 4 7

2 5 8 0

3 6 9 #

Fixing Hole

The Front

The Back

The Side

Product Parameters
Working Voltage:DC9-15V Static Current:120mA Reading Distance: 5-10cm Card Type: ID card Working Temperature: -15~55 Card Capacity: 3000pcs Input Interface: 1pcs exit button, 1pcs door magnet Output Interface: 1pcs lock control port (normal open, normal close), 1pcs door magnet alarm output port (normal close) Communication Mode: RS232/RS485 Reader Interface: Wiegand 26

Live Safely and Conveniently

Installation Manual
ASI-8930 ASI-8930

1. Remove the two keys first.

2. Unfasten the two screws.

Push up the back cover to open

First open the lower part of backcover for around 1cm. Please note that open too wide may lead to damage to the device.

3. Open the back cover and connect the device according to the wiring diagram.

4. Fix the backcover on the wall Reassemble the device. (according to 1, 2 and 3 in reversed order.

Live Safely and Conveniently

Product Connection
ASI-8930 Interface
Power Interface GND 12V Reader Interface Exit Button Interface
RX GND 12V 485 232 TX GND DAT0 485+ DAT1 485SW GND 2C 2NO MenC1 GND 1NO 1C BELL 1NC BELL

ASI-8930 ASI-8930

RX 485 232 TX GND 485+ 4852C 2NO 1NO 1C 1NC Lock Control Interface Door Magnet Alarm Output Interface RS485 Interface RS232 Interface

DAT0 DAT1 SW GND

Door Magnet Interface Door bell Interface

MenC1 GND BELL BELL

* Valid statedoor magnet is normal open.

Power Interface

ASI-8930 Interface

GND 12V DAT0 DAT1 SW GND MenC1 GND BELL BELL

GND

+12V

GND 12V DAT0 DAT1 SW GND MenC1 GND BELL BELL

RX TX GND 485+ 4852C 2NO 1NO 1C 1NC

GND

+12V

ASI-89 30 Interface

RX TX GND 485+ 4852C 2NO 1NO 1C 1NC

Power Interface

V+ VNO COM NC

Fail-safe Connect with EM Lock

Connect with Power


GND 12V DAT0 DAT1 SW GND MenC1 GND BELL BELL

+
Fail-secure

GND 12V DAT0 DAT1 SW GND MenC1 GND BELL BELL

ASI-8 9 30 Interface
RX TX GND 485+ 4852C 2NO 1NO 1C 1NC
+12V

ASI-8 9 30 Interface
RX TX GND 485+ 4852C 2NO 1NO 1C 1NC

Power Interface

Electric Bolt
GND

+12V
GND

+12V GND SIGNAL SIGNAL

Door Magnet Connect with Electric Lock Power Interface Iron Core Cover Plate

*Valid statedoor magnet is normal open.

Connect with Electric Bolt

Live Safely and Conveniently

Product Connection
ASI-8930 ASI-8930
GND 12V DAT0 DAT1 SW GND MenC1 GND BELL BELL GND 12V DAT0 DAT1 SW GND MenC1 GND BELL BELL

ASI-8930 Interface
RX TX GND 485+ 4852C 2NO 1NO 1C 1NC
Automatic Door Interface ( Switch Signal)

ASI-8930 Interface
RX TX GND 485+ 4852C 2NO 1NO 1C 1NC

Barrier Interface (Electric Level Signal)

Common end Stop Close Open

For this type of connection, the barrier switch is closed in normal status. When user presents card or presses the exit button, the barrier will be opened, The opening time depends on the door-open delay time. It is recommended to install ultra-red and ground sensor for protection.

COM1

COM2

The automatic door is open when COM1-COM2 is short circuit.

Connect with Barrier

Connect with Automatic Door

GND 12V DAT0 DAT1 SW GND MenC1 GND BELL BELL

GND 12V DAT0 DAT1 SW GND MenC1 GND BELL BELL

ASI-8930 Interface

ASI-8930 Interface

RX TX GND 485+ 4852C 2NO 1NO 1C 1NC

RX TX GND 485+ 4852C 2NO 1NO 1C 1NC

Exit Button
Active Boorbell Connect with Door Bell

ASI-8930 Interface
RX TX GND 485+ 4852C 2NO 1NO 1C 1NC

GND 12V DAT0 DAT1 SW GND MenC1 GND BELL BELL

Alarm Light

ASI-8930 Interface
RX TX GND 485+ 4852C 2NO 1NO 1C 1NC
Black Red Green White

GND 12V DAT0 DAT1 SW GND MenC1 GND BELL BELL

+
GND

1 4 7 *
+12V

2 5 8 0

3 6 9 #
2620

Connect with Alarm Device

Power Interface

Connect with Reader

Live Safely and Conveniently

Product Connection
ASI-8930 ASI-8930
RX GND TX 12V 485 232 TX GND DAT0 485+ 485+ DAT1 485SW GND GND 2C 2NO MenC1 GND GND 1NO 1C BELL 1NC BELL
ASI-8930 Interface

Converter

Connect with RS485


Rs232

PWD RxD TxD

RS485-RS232 Convertor

RS485
Rs485

RS232

T/R+ T/RGND

Computer Interface

RS485

485485+

Computer Interface For 485 communication, please follow the diagram for connection and no other connection mode should be used. DB9-Hole
12345

RS232
Connect with PC or Router
232 485 DC9~30V

RS485\TCP/IP

RX RX GND GND 12V 485 232 TX GND GND DAT0 DAT0 485+ DAT1 485485SW SW GND 2C 2NO 2NO MenC1 MenC1 GND GND 1NO 1C 1C BELL BELL 1NC BELL
ASI-8930 Interface Connect with PC or Router
232 485 DC9~30V Rs232

DB9-Hole
12345

Rs232

ASV-TCP/IP

9~30V+ 9~30V485+ 485Rj45 Rs485

RX GND TX 12V 12V 485 232 TX GND DAT0 485+ 485+ DAT1 DAT1 485SW GND GND 2C 2C 2NO MenC1 GND 1NO 1NO 1C BELL 1NC 1NC BELL BELL
ASI-8930 Interface

RS232\TCP/IP

ASV-TCP/IP

9~30V+ 9~30V485+ 485Rj45 Rs485

RX GND 12V 485 232 TX GND DAT0 485+ DAT1 DAT1 485SW GND 2C 2NO MenC1 GND 1NO 1C BELL 1NC 1NC BELL BELL
ASI-8930 Interface

Function Debugging
ASI-8930 ASI-8930
Test Reading Card Test Reading Card
Invalid Card: If the reader sounds twice after the card is presented to the reading area for one second, the card is invalid. Valid Card: If after the card is presented to the reading area for 0.5 seconds, the reader sounds once, green lights on and delay acts, then the card is valid.

Test the Keypad


When the buzzer sounds once, Dial *, the orange light flashes; Input000000, the orange light turns on and device enters program mode. This means the keypad is OK.
1 4 7 2 5 8 0 3 6 9 #

Test Output
Adjust the multimeter to , When the power is on, in normal state, 1C- 1 NC is short circuit , while 1 C- 1 NO is open circuit. When present the valid card or press the exit button, 1C-1NC turns into open circuit, while 1C1NO is short circuit.
GND 12V DAT0 DAT1 SW GND MenC1 GND BELL BELL
ASI-8930 Interface

RX TX GND 485+ 4852C 2NO 1NO 1C 1NC

1NC 1C 1NO
A

1NC 1C 1NO
Door-open State

Normal State

Test Input
GND 12V DAT0 DAT1 SW GND MenC1 GND BELL BELL
ASI-8930 Interface

If valid default input is normal open, no input available for the device when input signal is open-circuit; while input available when input signal is close-circuit. The status reversed when valid default input is normal close.The user can decide the type of default input setup in the software. 8930 has two input interfaces: SW-GND is button input; MenCi- GND is door magnet input. Both of them can be changed in channel setup.

RX TX GND 485+ 4852C 2NO 1NO 1C 1NC

Live Safely and Conveniently

Function Debugging
ASI-8930 ASI-8930
Connect with Exterior Identification Device
1. Select the device 3. Get the card number

After the exterior device is connected with ASI-8930, please select Tools---Card Register in the software program. Then, select the exterior device and start to read the card. If you can find the card number in the list, it means the exterior device works correctly.

2.Start to read card

Setup the Jumper

Test the Communication


ASI-8930 has two kinds of communication modes: RS232 and RS485. User can chose the communication mode by setting up the jumper. ASI-8930 can connect with PC serial port, and one serial port only connects with one ASI-8930. RS485 signal should be converted to RS232 signal before it can communicate with PC. RS485 can connect with multiple devices. After ASI-8930 is connected with PC, user can detect ASI-8930 address by detecting serial port (please refer to the user manual to setup the address). If connected is displayed, the communication is ok. User can get version and model number of ASI-8920 by inputting the address and clicking Auto Detect.

Rs485

Rs232

Anson 2007-04-16 1420

Test the LCD


The LCD will display the Anson and the time, after turn on the power for ASI-8930.

1 4 7

2 5 8 0

3 6 9 #

Test the time of ASI-8930


Time adjustment is shown in the picture on the left. The time of controller should be in consistent with PC. User can get updated time for controller by pressRefresh. If controller time is incorrect, card record may get lost, validity of cardread is in doubt, and moreover, valid card may turn into be invalid.

* otherwise the reader may not work properly.

PC time should be in consistent with controller time;

Live Safely and Conveniently

Product Maintenance
ASI-8930 ASI-8930

Common Question
1. If there is no sound when card is presented to the reading area, the reading function maybe damaged. 2. If there is no sound when press the keys, the keypad maybe damaged. 3. When add card, if the device exits program mode automatically, the memory maybe damaged. 4. If valid card is read and OK light is on, while relay does not act, the lock control may malfunction. 5. If relay keeps on in open state, buzzer keeps buzzing, and SW-GND is short or lower than 3.5V , the keys maybe damaged. 6. MenCi-GND is short or lower than 3.5V, the door magnet input maybe damaged. 7. Voltage of DATA0, DATA1 and GND should be higher than 3.5V, otherwise exterior reader can not work properly. 8. When RS485 is applied, voltage between 485+ and 485- is around 5 voltages. 9. The LCD have no information to be displayed, after turn on the power for ASI-8930. The starting program maybe damaged. The life of products is related to application environment and application method. Please carefully follow the product manual and installation manual. In case of any problem, please contact with our technical support instead of self-repairment. Please keep the original state of the products when sending back for repairment. Please notify us if you have any special demand, and we will feedback within 48 hours.

Urgent Maintenance 1. When the exterior reader can not read the cards, please test the voltage of DATA0GND and DATA1---GND. If the voltage is less than 3.5V, please weld TVS2, TVS3. 2. When door magnet input fails, please test the voltage between Menci and GND. If the voltage is less than 3.5V, please weld TVS5. 3. When exit button input fails, please test the voltage between SW and GND. If the voltage is less than 3.5V, please weld TVS4.

PCB

Live Safely and Conveniently