Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Delonghi TL Ecam23.420.Sb
Delonghi TL Ecam23.420.Sb
A UT OMA T IC C OF F E E MA C HINE S
DE LONGHI ECAM23.420
(INT/CH/ATE/DE/IT)
S E ZIO NE C A F F E ' / C O F F E E S E C T IO N
Sonda termica / Temperature probe °C 98 (Caffè / Acqua calda)
(Coffee / Hot water)
BIANCO/WHITE
ROSSO/RED
M2
ROSSO/RED
BIANCO/WHITE
M4
VERDE/GREEN
MOTOPROTETTORE POMPA
P
MARRONE/BROWN MARRONE/BROWN M3
MARRONE/BROWN
SCHEDA DISPLAY
A
DISPLAY PCB
J5 J1
MOTORE TRASMISSIONE
TRANSMISSION MOTOR BIANCO/WHITE
F1 B
J13 SCHEDA POTENZA
F2
+ ROSSO/RED POWER BOARD
+
M NERO/BLACK
F3 A
ROSSO/RED
MARRONE/BROWN
2
- - F4 B
J9 J6 J7 J8 J4 F5 B
SENSORE REED F7
REED SENSOR F8 BLU/BLUE
A I MARRONE/BROWN
A
1 2 3 4
A
BIANCO/WHITE 0 BLU/BLUE
YLW-GRN
NERO/BLACK
GIA-VER
ROSSO/RED
INTERRUTTORE ON/OFF
ON/OFF SWITCH
SONDA TEMP.
A
TEMP. PROBE
BIANCO/WHITE
NERO/BLACK
M1 M5
SCHEDA TECNICA ST1517/2009
FLUSSIMETRO
B
FLOWMETER
TCO
THERMAL CUT OFF GIA-VER/YLW-GRN
C
B
TCO
THERMAL CUT OFF
BIANCO/WHITE ROSSO/RED
D D C B
CALDAIA/BOILER
CELLA DI HALL
HALL CELL
M
MACININO/COFFEE GRINDER
M4 Tanica / Tank
M5 Rubinetto / Tap
SCHEMA ELETTRICO / ELECTRICAL DIAGRAM
MOTORE TRASMISSIONE
TRANSMISSION MOTOR
- +
M
SENSORE REED
SCHEDA DISPLAY
REED SENSOR
DISPLAY PCB
M2
J9
SONDA TEMP. J6
TEMP. PROBE
J13 J5
J1
FLUSSIMETRO
J7
FLOWMETER
CELLA DI HALL
J8
HALL SENSOR
J4
M1 M5
F7 SCHEDA POTENZA
POWER BOARD
M4
THERMAL CUT OFF
F5 POMPA/PUMP
P
F8 F4 F3 F2 F1
MACININO/COFFEE GRINDER
TCO
L L L L
PUMP THERMAL PROTECTOR
MOTOPROTETTORE POMPA
RESISTENZA
HEATING EL.
INTERRUTTORE ON/OFF
THERMAL CUT OFF
ON/OFF SWITCH
M
M3
TCO
Picture 1 Picture 2.
Take off water
tank
Picture 3.
Take off drip tray Picture 4.
and waste container Unscrew the 5 indicated screws
(Torx T20)
Picture 5
6.4
Lift upper panel
6.5
Take off cable
6.6
Unscrew the 2 indicated screws.
Then, lift with care the Control Panel
Page 2
Picture 7 - TO REMOVE COFFEE GRINDER
7.2 7.1
Lift coffee grinder pushing Take off cables on the right
it back with delicacy side of the board
7.3
To separate coffee grinder
unscrew the indicated screw.
8.1
Take off cable and
take out flowmeter
Page 3
9.2
Take off pump Picture 9 - TO REMOVE PUMP
9.3
9.1 Attention: After you have taken off cables,
Take off the spring you will have to take off pump thermal protector.
and then the tube Since it is glued, you will have to use a certain strength.
Attention: Some water could come out Remember to glue it again when you will reassemble it
from the tube, since the water circuit is
empting out
10.1
Take off the 4 indicated screws. After you have taken off cables, take out the board
Page 4
11.1
Unscrew the 4 indicated screw
you find on the rear of the motor
11.2
take off the 2 cables
and then take off
the DC motor.
Pay attention to
polarity when
replacing it
Page 5
12.1
Take off cables
Picture 12 - TO REMOVE TAP STEAM/HOT WATER
12.2
Unscrew the 2 indicated screws
12.3
Take off microswitch
Page 6
13.3
Take off the spring
indicated by the arrow and
then the tube
Picture 13 - TO REMOVE BOILER
13.2
Take off the
tube
13.1
Take off the indicated 2 springs
and the 4 screws.
13.4
Take off the cover.
Then unscrew the 2 indicated
screws to disassemble
the boiler
Page 7
Picture14 - TO REMOVE INFUSER KIT
Figura 14.1
Open infuser box.
Push the 2 buttons and take out
the infuser
Page 8
15.1
Unscrew the 10 indicated screws
Picture 15 - TO REMOVE TRANSMISSION KIT
15.2
Open infuser box
15.3
Unscrew the 2 indicated screws
(Torx T20) and remove the slider
15.4
Take off the indicated screw
Page 9
15.5
To remoce the Feeler Board (hall Sensor)
unscrew the 2 indicated screw to remove
the Hall sensor
15.6
Pay attention, when you take off the
plastic component, to the 2 indicated
metal spacers
(ATTENTION: about metal
spacers see Technical Info
IT0181)
Page 10
Picture 16 - TO REMOVE COFFEE SPOUT
16.1
Unscrew the 2 indicated screws
and remove the coffee spout
16.2
Pay attention to the spring
assembled with slider
Pag. 11
17.2
Picture 17 - TO REMOVE VALVE ASSEMBLY
Unscrew the 2 indicated screws
(ATTENTION: see Technical Info IT0181)
using an Allen key (4)
17.1
Take off the 2 springs
and then the
tubes
17.3
Take off the spring
and then the tube
which goes from
coffee spout to
infuser
17.4
Unscrew the indicated screw
17.5
to take off microswitch
Take off microswitch
Page 12
Picture 18 - HOW TO ALIGN VALVE
Lift the infuser up to to touch the valve, without pushing with strength: it has only to be
aligned to the valve.
Once you aligned it, fix the 2 screws (pic. 18.2) using an Allen key.
18.1
Screw the 2 indicated screws
using an Allen key (4)
18.2
Fit in the tube
and then
the spring
Page 13
Picture 19 - MICROSWITCH AND
WATER REED POSITION
19.1
Water Tank
microswitch
19.3
Steam tap
microswitch
19.4
Infuser bottom limit
microswitch
19.5
Waste container
microswitch
19.6
Reed switch
water tank
Page 14
WATER CIRCUIT
VALVE
BOILER
INFUSER
SAFETY
VALVE
EXPANSION
PUMP CHAMBER
DUMPER
FLOWMETER
DRIP TRAY
WATER TANK
FILTER
TEST PROCEDURE FOR
ECAM23.420 INTENSA
Water Pump ON
NOTE: Water Tank micro, Waste container micro and Steam tap micro beep when are open
To EXIT the procedure, press On/Off Swicth (position 0) or unplug the machine.
DISPLAY TEST PROCEDURE FOR
ECAM23.420 INTENSA
BUTTON 3
BUTTON 4
BUTTON 5
BUTTON 7
Note: Release buttons after you read the Turning the knob,
the display will show
message “DISPLAY TEST MODE”. the bar increasing
or decreasing.
NOTE: After display Test performing, you need to intialize the machine.
To EXIT the procedure, press On/Off Swicth (position 0) or unplug the machine.
Test procedure ends automatically 1 minute after you completed it.
ACCESSIBILITA’
Figura 1 Figura 2.
Togliere serbatoio
acqua
Figura 3.
Togliere il cassetto Figura 4.
reccolta fondi Svitare le 5 viti indicate
(Torx T20)
Figura 5
6.4
Sfilare copertura superiore
6.5
Sganciare la piattella
6.6
Togliere le due viti
del cruscotto. Sollevare
quindi leggermente
verso l’altro per sganciarlo
Pag. 2
Figura 7 - SMONTAGGIO MACININO
7.2 7.1
Sollevare il macinino Sganciare i cavetti del motore
spostandolo lievemente dal lato destro della scheda
verso la parte posteriore
7.3
Per disassemblare il macinino
togliere la vite indicata
8.1
Sfilare il connettore
ed estrarre verso
l’esterno
il flussimetro
Pag. 3
9.2
Sfilare la pompa Figura 9 - SMONTAGGIO POMPA
9.1 9.3
Togliere la forcina Attenzione: Dopo aver sganciato il cablaggio,
di aggancio e quindi sfilare il klixon. Essendo incollato, esercitare
sfilare il tubo una certa forze. Ricordarsi di incollarlo
Attenzione: dal tubo potrebbe uscire nuovamente
una piccola quantità d’acqua, in quanto
il circuito idaraulico si svuota
10.1
Togliere le quattro viti indicate. Dopo aver staccato i cablaggi, sfilare la scheda
Pag. 4
11.1
Togliere le 4 viti di fissaggio del motore,
raggiungibili dalla parte posteriore
11.2
staccare i due cavetti
e sfilare il motore
a corrente continua.
Fare attenzione alla
polarità al momento
della sostituzione
Pag. 5
12.1
Scollegare i cavi Figura 12 - SMONTAGGIO RUBINETTO
12.2
Togliere le viti indicate
12.3
Sfilare il micro
Pag. 6
13.3
Togliere la forcina indivata
dalla freccia e sfilare il tubo
13.2
Stccare il tubo
indicato
13.1
Sfilare le 2 forcine
e togliere le 4 viti
13.4
Una volta tolta la chiusura,
svitare le viti indicate per
estrarre la cladaia
Pag. 7
Figura 14 - ESTRAZIONE INFUSORE
Figura 14.1
Aprire il vano infusore.
Premere i due tasti indicati
ed estrarre l’infusore
Pag. 8
15.1
Togliere le 10 viti indicate Figura 15 - SMONTAGGIO GRUPPO MOVIMENTAZIONE
15.2
Aprire vano infusore
15.3
Togliere le 2 viti indicate
(Torx T20)
15.4
Togliere la vite di fissaggio della slitta
15.6
Fare attenzione, nel momento in cui
si toglie la slitta, ai 2 distanziali indicati nel
disegno
(ATTENZIONE: per i
distanziali vedere info
IT0181)
Pag. 10
Figura 16 - SMONTAGGIO EROGATORE CAFFE’
Figura 16.1
Togliere le 2 viti indicate per smontare
l’erogatore
16.2
Fare attenzione alla molla
montata sul cursore
Pag. 11
17.2
Utilizzando una chiave a brugola (4)
Figura 17 - SMONTAGGIO MECCANOVALVOLA togliere le due viti di fissaggio della
(ATTENZIONE: vedere info IT0181) staffa
17.1
Togliere le 2 forcine e
sfilare i tubi
17.3
Togliere la forcina e
sfilare il tubo che
dall’erogatore
arriva all’infusore
17.4
Per togliere il microinterruttore,
17.5 svitare la vite indicata
Estrarre il microint.
Pag. 12
Figura 18 - ALLINEARE LA MECCANOVALVOLA
Far salire l’infusore fino a farlo arrivare a contatto della meccanovalvola, senza esercitare pressione
per farli entrare in contatto: devono solo essere allineati.
Una volta completata l’operazione, fissare le due viti (fig. 18.2) con una chiave a brugola
18.1
Avviatare le 2 viti indicate
con una chiave a brugola (4)
18.2
Inserire il tubo
e la forcina
Page 13
Figura 19. POSIZIONAMENTO
MICROINTERRUTTORI E REED
19.1
Microinterruttore Tanica
19.3
Microinterruttore
Rubinetto
19.4
Microinterruttore inizio corsa
Infusore
19.5
Microinterruttore
Cassetto fondi
19.6
Reed tanica
Pag. 14
SCHEMA IDRAULICO
MECCANOVALVOLA
GENERATORE
INFUSORE
VALVOLA DI
SICUREZZA
CAMERA DI
POMPA ESPANSIONE
DUMPER
FLUSSIMETRO
VASCHETTA
DI RACCOLTA
SERBATOIO
FILTRO
PROCEDURA DI TEST PER LA
ECAM23.420 INTENSA
Pompa Acqua ON
NOTA : I micro Tanica, Cassetto Fondi e Vapore emettono un beep quando sono aperti
BUTTON 3
BUTTON 4
BUTTON 5
BUTTON 7