Sei sulla pagina 1di 2

Hydrocarbon management specialists www.banlaw.

com

FILTERED TANK VENTS


-10µm NOMINAL RATING -

Protect your diesel


fuel system from
the damaging effects
of airborne particle
contamination.
Heavy equipment typically operates in dusty, dirty conditions. A generic Quick-Fill tank vent has no means of
preventing airborne contamination entering a tank, unlike the Banlaw Filtered Vent which comes with a
serviceable air filter within the vent cap. This filter protects against particles entering the tank via the vent,
and thus entering the fuel system of the equipment. The service life of OEM fuel filters is extended, reducing
the risk of blocked filters and equipment downtime.

BENEFITS OF BANLAW FILTERED VENTS


• Flexible Vent Solutions • High Quality Filter Element
Banlaw offers a flexible and complete range of 1O µm nominal rating - triple layer multi density
vents for all applications and O.E.M's. foam - excellent chemical resistance - positive seal
between mating
• Faster Refuelling surfaces - field
Creating LOW restriction to exhaust air, a single serviceable - high
vent will cater for < 800LPM refuelling rates! flow capability with
low restriction - high
• Rugged Construction retention capacity &
Built for the rugged mining environment from cast extended service life
aluminium - NOT plastic!

• No Spill
The Banlaw patented splash tube ensures the
correct operation of the float balls at all times.
Features:
• Suitable for flat or round top fuel tanks.
• Vapour relief pressure approximately :-
110 kPa (Red cap) and 49kPa (Green cap)
• 3/4" N.B. throughout
• 1/16" bleed hole
• Splash tube (except on Rail spec vents)
• "A" Series has 2" NPT male taper threads
• 'O' Ring seals provide reliable & extended service
• Relief valve exhaust bypasses filter element (BP125A Vent Shown)

Hydrocarbon management specialists


Hydrocarbon management specialists www.banlaw.com

B F
J
600
550

D if f e r e n t ia l P r e s s u r e ( k P a )

N
500

O
C D H E G

SI
IS
450

SM
AN
400

TR
350
Nozzle Receiver 300 SE
CA
250 NK
A CR
A
L IC
200 AU
DR
HY
150
100
50
0
25 50 75 100 125 150 175 200 225 250 275 300

Flowrate (LPM)
* DATA OBTAINED USING ISO68 HYDRAULIC OIL @ 40-45ºC. IMPORTANT: DIFFERENTIAL
Nozzle & Receiver Connected PRESSURE WILL VARY HANDLING A FLUID WITH A DIFFERENT VISCOSITY.
DATA INDICATES FLUID FLOW FROM NOZZLE TO RECEIVER. RESULTS MAY VARY SLIGHTLY
UNDER REVERSE FLOW.
TESTS CONDUCTED BY CCI ENGINEERING, NEWCASTLE, AUSTRALIA DURING APRIL 2004.

Hydraulic Crankcase Transmission Coolant


Fitting Type
Receiver Nozzle Receiver Nozzle Receiver Nozzle Receiver Nozzle
Part Number BPLR6DN BPLN6DB BPLR4CB PLN4BB BPLR3CB BPLN4CB BPLR1BN BPLN1BN
Safe Working Pressure - - - 6.75 979 - - 6.5 943
- 5.0 725 - 6.5 943 -
MPa - PSI
Burst Pressure - - 20.0 2901 26.0 3771 27.0 3916 26.0 3771
MPa - PSI
Safe Working Pressure 4.5MPa (653 psi) 7.0MPa (1015 psi) 8.75MPa (1269 psi) 6.0MPa (870 psi)
Nozzle/Receiver Coupled
Dimensions mm.
A 124 110.5 97 91.5
B 89.5 76.5 68 64
ØC 62 55 50 46
Thread D (female) 1¼” BSP 1” BSP 1” BSP 1” BSP
Thread E (male) 1¼” BSP 1” BSP 1” BSP ¾” BSP
F 79 75.5 67.5 63
ØG 56 50 46 41
ØH 37 31.5 28 24
J 22 21 21 20
This data clearly illustrates the low restriction to airflow created by the Banlaw Filtered Vent. Vents and filters with
• higher
Specifications
restriction pressure the tank during refuelling. Tank •pressure
Part No.prior to the tank being filled creates an increased
Description
SafeofWorking
risk Pressure
premature (SWP)
shut-off of the quick-fill nozzle. The operatorStandard
is then Fitting:
inclined to manually hold the nozzle ON, leading
BPLR6DN
to- Maximum Recommended
spillage of Working Pressure. of the fuel tank.
fuel and overpressurisation NPT Hose Tail: add suffix ‘N’ to Part No. e.g. BP64N
Burst Pressure (BP) Receiver and Dust Cap Assembly: BP64&C or BP64N&C
- Minimum Pressure at which fitting will suffer failure. Receiver Dust Cap alone: BPLR6-C
Seal Material - either Viton or HNBR
Call your Authorised Banlaw Distributor:
Call for a full consultation
Banlaw Pipeline Pty. Ltd.
17 Strathmore Road
Caves Beach NSW 2281
Australia
Telephone +61 (0)2 49724777
Fax. +61 (0)2 49714910
Website: www.banlaw.com Please Note: Use only Banlaw factory replacement parts.
Email: sales@banlaw.com.au
Non-genuine parts may cause equipment failure or malfunction,
ABN 88 062 044 071 and invalidate factory warranty.

hydrocarbon management
Hydrocarbon specialists
management specialists

Potrebbero piacerti anche