Duct Type
AMNH096BTG0 AMNH126BTG0 AMNH186BTG0 AMNH096BPA0 AMNH126BPA0 AMNH186BHA0 AMNH246BHA0 AMNH306BGA0 AMNH366BGA0
1 Way CST
AMNH096TCC0 AMNH126TCC0
4 Way CST
AMNH126TEC0 AMNH186TEC0 AMNH246TFC0 AMNH306TFC0 AMNH366TDC0
CVT
AMNH096VEA0 AMNH126VEA0 AMNH186VBA0 AMNH246VBA0
TABLE OF CONTENTS
Model Number Nomenclature ....................................................................................................................3 Symbols Used in this Manual ...................................................................................................................5 Safety Precautions......................................................................................................................................6 Dimensions................................................................................................................................................12 Indoor Unit.............................................................................................................................................12 Outdoor Unit ...........................................................................................................................................20 Product Specifications ............................................................................................................................22 Installation .................................................................................................................................................28 Select the best location of indoor unit ....................................................................................................28 How to fix ...............................................................................................................................................31 Piping and Drainage of Indoor Unit ........................................................................................................38 Connection of indoor unit piping.............................................................................................................39 Remote Controller Installation ................................................................................................................62 Connecting Pipings and the cable to Outdoor unit .................................................................................64 Checking the Drainage and Pipe forming...............................................................................................66 Maximum Length of Pipe and Extra Charge of Refrigerant Charge.......................................................71 Test Running ..........................................................................................................................................78 System Layout and Piping Length..........................................................................................................81 Installation ..............................................................................................................................................82 Installation of The Main Unit...................................................................................................................83 Connection of Piping ..............................................................................................................................84 Connection of Wiring ..............................................................................................................................85 Operation ..................................................................................................................................................86 Function of control..................................................................................................................................86 Function of Indoor Unit ...........................................................................................................................91 Function of Outdoor Unit ........................................................................................................................97 Remote Control Operation .....................................................................................................................98 Control Devices and Function ...............................................................................................................106 Simple Central Control .........................................................................................................................106 Term of Each part and Function ...........................................................................................................106 Electrical wiring ....................................................................................................................................107 Deluxe Central Control .........................................................................................................................113 Disassembly of the parts (Indoor unit) .................................................................................................119 Indoor unit ............................................................................................................................................119 Schematic Diagram.................................................................................................................................133 Electronic Control Device .....................................................................................................................133 Wiring Diagram.....................................................................................................................................142 Components Locations.........................................................................................................................146 Troubleshooting Guide ...........................................................................................................................161 Refrigeration Cycle Diagram ................................................................................................................161 Self-diagnosis Function ........................................................................................................................166 Cycle Troubleshooting Guide................................................................................................................167 Electronic Parts Troubleshooting Guide ...............................................................................................168 General Information..............................................................................................................................173 (3-way) Valve ...........................................................................................................................................189 Exploded View & Replacement Parts List ............................................................................................193 Indoor Unit ...........................................................................................................................................193 Outdoor Unit ........................................................................................................................................222
Electrical Rating
6 : 1, 220-240V, 50Hz
Model Type
H : Heat Pump
Outdoor Unit
A2U W 18 6 F A 0
Serial Number Function
A : Basic
Multi Type
F : Free Joint Multi Type
Electrical Ratings
6 : 1, 220-240V, 50Hz 8 : 3, 380-415V, 50Hz
Model Type
W : DC Inverter Heat Pump
R410A TPS Inverter Multi System Outdoor Unit. And No. of Connectable Indoor Units Ex) A2U : Connectable max. 2 Indoor Units A6U : Connectable max. 6 Indoor Units
Service Manual 3
P 1
T 2
H 4
E 5
A 6
Number 1, 2 3 4 5 6
Plasma Filter Elevation Grille Elevation Grille + Plasma Filter TE/TB/TD Before 2003 : Basic TE/TD Before 2003 : Plasma Filter
Indoor Units
Category Type Chasiss 2.1 (7000) AMNH 076LQL0 AMNH 076DZ*0 2.6 (9000) AMNH 096LQL0 AMNH 096LRL0 AMNN 096AP*1 AMNH 096DU*0 AMNH 096TCC0 AMNH 096BTG0 AMNH 096BPA0 AMNH 096VEA0 Model Name Capacity, kW(Btu/h) 3.5 5.3 (12000) (18000) AMNH 126LRL0 AMNN 126AP*1 AMNH 126DU*0 AMNH 126TCC0 AMNH 126TEC0 AMNH 126BTG0 AMNH 126BPA0 AMNH 126VEA0 AMNH 186LTL0 AMNH 186TEC0 AMNH 186BHA0 AMNH 186BTG0 AMNH 186VBA0 7.0 (24000) AMNH 246LTC0 AMNH 246TFC0 AMNH 246BHA0 AMNH 246VBA0 8.8 (30000) AMNH 306TFC0 AMNH 306BGA0 10.6 (36000) AMNH 366TDC0 AMNH 366BGA0 -
SQ Wall Mounted General SR ST General ART COOL Mirror SU 1Way Ceiling Cassette TC TE 4Way TF TD High Static Low Static Built in Ceiling & Floor Convertible VB BH BG BT BP VE SP1 SZ
Outdoor Units
TPS Inverter Multi Series
Heat Pump Rated Capacity
Distributor Type
A6UW406FA0 11.7(40000) 13.5(46000) Max.6 Units 4.7~15.2 16000~52000 A7UW486FA0 14.0(48000) 16.2(55200) Max.7 Units 5.6~18.3 19200~62400 A8UW566FA0 16.4(56000) 18.9(64400) Max.8 Units 6.6~21.3 22400~72800
Model Name A2UW146FA0 A2UW186FA0 A3UW186FA0 A3UW246FA0 A4UW246FA0 A4UW306FA0 Cooling kW(Btu/h) 4.7(1600) 5.3(18000) 5.3(18000) 7.0(24000) 7.0(24000) 8.8(30000) Heating kW(Btu/h) 5.3(1800) 6.3(21600) 6.3(21600) 8.2(28000) 8.2(28000) 10.1(34500) Number of Indoor Units to be Connected Max.2 Units Max.2 Units Max.3 Units Max.3 Units Max.4 Units Max.4 Units Indoor Units kW 2.1~6.2 2.1~7.0 2.1~7.0 2.1~9.7 2.1~9.7 2.1~11.4 Connectable Capacity Btu/h 7000~21000 7000~24000 7000~24000 7000~33000 7000~33000 7000~39000 Power Supply 1, 220-240V, 50Hz
Notes : A2UW146FA0, A2UW186FA0 and A3UW186FA0 are not TPS inverter system but one inverter compressor system.
Service Manual 5
Safety Precautions
Safety Precautions
To prevent injury to the user or other people and property damage, the following instructions must be followed. s Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications.
WARNING CAUTION
This symbol indicates the possibility of death or serious injury. This symbol indicates the possibility of injury or damage to properties only.
WARNING
s Installation
Do not use a defective or underrated circuit breaker. Use this appliance on a dedicated circuit.
There is risk of fire or electric shock.
For electrical work, contact the dealer, seller, a qualified electrician, or an Authorized Service Center.
Do not disassemble or repair the product. There is risk of fire or electric shock.
Do not let the air conditioner run for a long time when the humidity is very high and a door or a window is left open.
Take care to ensure that power cable could not be pulled out or damaged during operation.
Moisture may condense and wet or There is risk of fire or electric damage furniture. shock.
Service Manual 7
Safety Precautions Do not plug or unplug the power supply plug during operation.
There is risk of fire or electric shock.
Do not use the product in a tightly closed space for a long time.
Oxygen deficiency could occur.
Gasolin
When flammable gas leaks, turn off the gas and open a window for ventilation before turn the product on.
Do not use the telephone or turn switches on or off. There is risk of explosion or fire
If strange sounds, or small or smoke comes from product. Turn the breaker off or disconnect the power supply cable.
There is risk of electric shock or fire.
Stop operation and close the window in storm or hurricane. If possible, remove the product from the window before the hurricane arrives.
There is risk of property damage, failure of product, or electric shock.
Safety Precautions Do not open the inlet grill of the product during operation. (Do not touch the electrostatic filter, if the unit is so equipped.)
There is risk of physical injury, electric shock, or product failure.
When the product is soaked (flooded or submerged), contact an Authorized Service Center.
There is risk of fire or electric shock.
Ventilate the product from time to time when operating it together with a stove, etc.
There is risk of fire or electric shock.
Turn the main power off when cleaning or maintaining the product.
There is risk of electric shock.
When the product is not be used for a long time, disconnect the power supply plug or turn off the breaker.
Take care to ensure that nobody could step on or fall onto the outdoor unit.
There is risk of product damage or failure, or unintend- This could result in personal injury and product damed operation. age.
CAUTION
s Installation
Always check for gas (refrigerant) leakage after installation or repair of product.
Low refrigerant levels may cause failure of product.
Install the drain hose to ensure that water is drained away properly.
A bad connection may cause water To avoid vibration or water leakleakage. age.
90
Service Manual 9
Safety Precautions Do not install the product where the noise or hot air from the outdoor unit could damage the neighborhoods.
It may cause a problem for your neighbors.
Do not install the product where it will be exposed to sea wind (salt spray) directly.
It may cause corrosion on the product. Corrosion, particularly on the condenser and evaporator fins, could cause product malfunction or inefficient operation.
s Operational
Do not expose the skin directly to cool air for long periods of time. (Don't sit in the draft.)
This could harm to your health.
Do not use the product for special purposes, such as preserving foods, works of art, etc. It is a consumer air conditioner, not a precision refrigeration system.
There is risk of damage or loss of property.
Use a soft cloth to clean. Do not use harsh detergents, solvents, etc.
There is risk of fire, electric shock, or damage to the plastic parts of the product.
Do not touch the metal parts of the product when removing the air filter. They are very sharp!
There is risk of personal injury.
x Wa Thinner
Safety Precautions Do not step on or put anyting on the product. (outdoor units)
There is risk of personal injury and failure of product.
Always insert the filter securely. Clean the filter every two weeks or more often if necessary.
A dirty filter reduces the efficiency of the air conditioner and could cause product malfunction or damage.
Do not insert hands or other objects through the air inlet or outlet while the product is operated.
There are sharp and moving parts that could cause personal injury.
Replace the all batteries in the remote control with new ones of the same type. Do not mix old and new batteries or different types of batteries.
There is risk of fire or explosion
If the liquid from the batteries gets onto your skin or clothes, wash it well with clean water. Do not use the remote if the batteries have leaked.
The chemicals in batteries could cause burns or other health hazards.
Service Manual 11
Dimensions
Dimensions
Indoor Unit
1. Split Type Indoor 2. Art Cool Type Indoor Unit
W D
Pipe Hole
Hanger Hole
Fix Hole
"D"
20mm
Center
A A
"C"
20mm
Center
Hole Center
70mm
(7K, 9K)
MODEL DIM W H D mm mm mm SQ 7K,9K 824 260 155
(9K, 12K)
SR 9K, 12K 900 285 156
(18K, 24K)
ST 18K, 24K 1,080 314 172
Dimensions
D W
Installation plate
Service Manual 13
Dimensions
4. Duct Type
BH/BG
D W D
H H
BP
BT/BT1
BT 9K/12K 708
BH 18K/24K 880
BG 30K/36K 1180
BP 9K/12K 580
H(mm)
230
230
260
298
300
D(mm)
537
357
450
450
750
Dimensions
D
63mm 38mm
26
5m
39 m
2m
250mm
36
mm
46
8m
175mm
10
76
mm
(Installation Plate)
36 mm
(Rear Side)
VE(9K/12K)
D
Installation plate
Service Manual 15
Dimensions
30.8
1 3 2
50 194.4 42.7
390 328.4
164
155
91.6 180
1050 694.5
480
(unit : mm) Number 1 2 3 4 5 6 Name Liquid pipe connection Gas pipe connection Drain pipe connection Power supply connection Air discharge grill Air suction grill Descripition 6.35 flare 9.52 flare
Dimensions
269
570 Unit size
670 670
Unit:mm
670
570 450
570
670
CLOSE
OPEN
OPEN
CLOSE
521
40
4
30
(unit : mm) Number 1 2 3 4 5 6 Name Liquid pipe connection Gas pipe connection Drain pipe connection Power supply connection Air discharge grill Air suction grill Descripition 6.35 flare 12k: 9.52, 18k: 12.7 flare
Service Manual 17
52
Dimensions
66
292 850 850
Unit:mm
850
572 744
6
70
4 1 2
117
110 90
110 90 150
3
292
66
192
30
(unit : mm) Number 1 2 3 4 5 6 Name Liquid pipe connection Gas pipe connection Drain pipe connection Power supply connection Air discharge grill Air suction grill Descripition 6.35 flare 12.7 flare-24K, 15.88 flare-30K
54
Dimensions
950
Unit:mm
840 678
950
55
840
785
40
1 2
30
290
110 90
140
(unit : mm) Number 1 2 3 4 5 6 Name Liquid pipe connection Gas pipe connection Drain pipe connection Power supply connection Air discharge grill Air suction grill Descripition 6.35 flare 15.88 flare
Service Manual 19
210.5
90
Dimensions
Outdoor Unit
D
L2
L1
30K/40K
L3
L4
L6
L5
L7
18K/24K
MODEL DIM W H D L1 L2 L3 L4 L5 L6 L7 mm mm mm mm mm mm mm mm mm mm
18K
870 655 320 370 25 775 25 546 160 160
24K
870 800 320 370 25 775 25 546 160 160
30K
870 1060 320 360 20 1040 20 550 160 165
40K
900 1165 370 460 45 1135 30 550 175 175
Dimensions
A7UW486FA0/A8UW566FA0
15 153 806 500(bolt hole) 153
Air outlet
40
Service Panel
670
220
Knockout hole (For the control wiring, the power supply, refrigerant connecting pipe)
100 28
Knockout hole (For the control wiring, the power supply, refrigerant connecting pipe)
(Unit : mm)
Service Manual 21
Product Specifications
Product Specifications
Indoor Unit
Indoor Unit Type Model Rated Cooling Capacity 5 Rated Heating Capacity 5 Air Circulation H/M/L Setting temperature range Fan motor Output Model No. of Poles Input Running Current Capacitor Fan Type No. Used / Diameter Fan RPM Cooling(H/M/L) Heating(H/M/L) Noise Level(Sound Press,1m) H/M/L Temperature controller Coil Tube Size (OD) Fins per inch No. of Rows & Column Dehumidification Rate Dimensions (W*H*D) Net Weight Piping Liquid Connection Gas Drain hose (ID ) Packing Dimension (W*H*D) Stuffing Quantity Without S/Parts Front Panel Color "5" Position kcal/hr(W) Btu/hr kcal/hr(W) Btu/hr CMM(CFM) C W AMNH076LQL0 AMNH096LQL0 Wall Mounted AMNH096LRL0 2267(2638) 9000 2520(2929) 10000 8.5(300) 18~30 / 16~30 14.4 IC-8420LG48A 4 37 0.16 0.9 / 400 Cross Flow Fan 1/3.43(87) 1200/1100/1000 1200/1100/1000 35 / 33 / 31 Thermistor 0.197(5.0) 20 2R,12C 1.4 35.4*11.2*6.1(900*285*156) 8(17.6) 1/4 (6.35) 3/8 (9.52) 20 38.4*9.2*14.6(976*233*372) 338/714 (340/720) Morning Beige AMNH126LRL0 3024(3515) 12000 3326(3867) 13200 9.0(318) 18~30 / 16~30 14.4 IC-8420LG48A 4 37 0.16 0.9 / 400 Cross Flow Fan 1/3.43(87) 1290 / 1200 / 1120 1290 / 1200 / 1120 39 / 36 / 34 Thermistor 0.197(5.0) 20 2R,12C 1.8 35.4*11.2*6.1(900*285*156) 8(17.6) 1/4 (6.35) 3/8 (9.52) 20 38.4*9.2*14.6(976*233*372) 338/714 (340/720) Morning Beige AMNH186LTL0 4536(5275) 18000 4990(5803) 19800 13(459) 18~30 / 16~30 22 AMR-023E2 4 54 0.21 2.0 / 370 Cross Flow Fan 1/3.74(95) 1140 / 1040 / 940 1140 / 1040 / 940 42 / 39 / 36 Thermistor 0.276(7.0) 20 2R,13C 2.0 42.9*12.4*6.8(1090*314*172) 12(26.5) 1/4 (6.35) 1/2 (12.7) 20 45.9*10.0*15.3(1165*255*388) 264/536 (270/540) Morning Beige AMNH246LTL0 5544(6446) 22000 6099(7091) 24200 14(494) 18~30 / 16~30 29 AMR-023E5 6 59 0.21 2.0 / 370 Cross Flow Fan 1/3.74(95) 1260 / 1140 / 1000 1260 / 1140 / 1000 46 / 43 / 39 Thermistor 0.276(7.0) 20 2R,13C 2.5 42.9*12.4*6.8(1090*314*172) 12(26.5) 1/4 (6.35) 1/2 (12.7) 20 45.9*10.0*15.3(1165*255*388) 264/536 (270/540) Morning Beige
1764(2051) 2267(2638) 7000 9000 2016(2343) 2520(2929) 8000 10000 5.5(194) 8.5(300) 18~30 / 16~30 18~30 / 16~30 8.4 8.4 IC-8415LG62A IC-8415LG62A 4 4 25 25 0.11 0.11 0.9 / 400 0.9 / 400 Cross Flow Fan Cross Flow Fan 1/3.43(87) 1/3.43(87) 1080 / 970 / 880 1170 / 1100 / 1020 1080 / 970 / 880 1170 / 1100 / 1020 35 / 32 / 29 37 / 33 / 31 Thermistor Thermistor 0.197(5.0) 0.197(5.0) 19 19 2R,10C 2R,10C 1.0 1.2 32.4*10.2*6.1(824*260*155) 32.4*10.2*6.1(824*260*155) 7(15.4) 7(15.4) 1/4 (6.35) 1/4 (6.35) 3/8 (9.52) 3/8 (9.52) 20 20 35.4*9.2*13.4(900*233*340) 35.4*9.2*13.4(900*233*340) 354/774 (360/780) 354/774 (360/780) Morning Beige Morning Beige
Indoor Unit Type Model Rated Cooling Capacity 5 Rated Heating Capacity 5 Air Circulation H/M/L Setting temperature range Fan motor Output Model No. of Poles Input Running Current Capacitor Fan Type No. Used / Diameter Fan RPM Cooling(H/M/L) Heating(H/M/L) Noise Level(Sound Press,1m) H/M/L Temperature controller Coil Tube Size (OD) Fins per inch No. of Rows & Column Dehumidification Rate Dimensions (W*H*D) Net Weight Piping Liquid Connection Gas Drain hose (ID ) Packing Dimension (W*H*D) Stuffing Quantity Without S/Parts Front Panel Color "5" Position kcal/hr(W) Btu/hr kcal/hr(W) Btu/hr CMM(CFM) C W AMNH076DZ*0
1764(2051) 2267(2638) 2772(3224) 7000 9000 12000 1940(2257) 2495(2901) 3049(3546) 8000 10000 13200 5.5(194) 8.5(300) 9.0(318) 18~30 / 16~30 18~30 / 16~30 18~30 / 16~30 4.7 7.8 7.8 OBM-1547P2 OBM-1547P2 OBM-1547P2 4 4 4 27 40 40 0.12 0.18 0.18 0.9/400 0.9/400 0.9/400 Cross Flow Fan Cross Flow Fan Cross Flow Fan 1/3.43(87) 1/3.43(87) 1/3.43(87) 1330/1230/1130 1320/1220/1120 1400/1300/1200 1330/1230/1130 1320/1220/1120 1400/1300/1200 35 / 32 / 29 37 / 33 / 31 39 / 36 / 34 Thermistor Thermistor Thermistor 0.197(5.0) 0.197(5.0) 0.197(5.0) 19 19 19 2R,12C 2R,12C 2R,12C 1.0 1.2 1.5 42.9*12.4*6.8(1090*314*172) 35.4*10.7*5.3(900*272*135) 40.6*11.4*6.0(1030*290*153) 8.1(17.9) 9.5(20.9) 9.5(20.9) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 3/8(9.52) 3/8(9.52) 3/8(9.52) 20 20 20 38.8*8.7*14.3(985*220*363) 44.0*8.9*14.8(1117*225*377) 44.0*8.9*14.8(1117*225*377) 340/720 324/684 324/684 R:Mirror, M:Metal, N:Walnut, W:White, B:Blue, C:Cherry
2267(2638) 2772(3224) 9000 12000 2520(2929) 3049(3546) 10000 13200 7.5(264) 8.5(300) 18~30 / 16~30 18~30 / 16~30 24 24 SIC-39CV-D828-1 SIC-39CV-D828-1 8 8 18 18 0.08 0.08 Turbo Fan Turbo Fan 1/24.32(617.7) 1/24.32(617.7) 510/350/290 560/460/360 510/350/290 560/460/360 38 / 35 /32 43 / 40 / 33 Thermistor Thermistor 0.197(5.0) 0.197(5.0) 20 20 2R,20C 2R,20C 1 1.2 22.4*22.4*5.4 (570*568*137) 22.4*22.4*5.4 (570*568*137) 9(19.84) 9(19.84) 1/4 (6.35) 1/4 (6.35) 3/8 (9.52) 3/8(9.52) 20 20 25.7*25.2*8.5(653*641*216) 25.7*25.2*8.5(653*641*216) 239/539 239/539 M:Metal, B:Blue, D:Wood
Note : 1.5 See the page "Combination Table" 2. Due to our policy of innovation some specifications may be changed without notification.
2267(2638) 9000 2520(2929) Rated Heating Capacity 5 10000 9(317) Air Circulation H/M/L External Static Pressure 18~30 / 16~30 Setting temperature range 14 Fan motor Output AMR-023E7 Model 4 No. of Poles 50 Input W 0.56 Running Current A 0.9/400 Capacitor F/Vac Cross Flow Fan Fan Type 1/4(102) No. Used / Diameter EA/inch(mm) 900 / 800 / 700 Fan RPM Cooling(H/M/L) rpm 900 / 800 / 700 Heating(H/M/L) rpm 35 /32 / 28 Noise Level(Sound Press,1m) H/M/L dBA Thermistor Temperature controller 0.275(7) Coil Tube Size (OD) inch(mm) 18 Fins per inch 2R11C No. of Rows & Column 1.2 Dehumidification Rate l/h Dimensions (W*H*D) Indoor inch(mm) 33.8*15.3*7(860*390*190) Panel inch(mm) 41.3*18.9*1.2(1050*480*30) 22(48.5) Net Weight kg(lbs) 1/4 (6.35) Piping Liquid inch(mm) 3/8(9.52) Connection Gas inch(mm) 32 Drain hose (ID ) mm 38.6*10.0*18.1 Packing Dimension (W*H*D) inch(mm) 263/539 Stuffing Quantity Without S/Parts 20/40ft
4536(5275) 6048(7033) 7056(8206) 18000 24000 28000 4990(5803) 6653(7736) 7761(9027) 19800 26400 30800 13(459) 15/14/13(53/494/459) 18(636) 18~30 / 16~30 18~30 / 16~30 18~30 / 16~30 22.4 40.3 45 IC-9630LGAC OBM-350292 OBM-401592 6 6 6 90 121 146 0.75 0.53 0.67 2.5/440 4/440 4/440 Turbo Fan Turbo Fan Turbo Fan 1/13.0(330) 1/15.0(382) 1/15.0(382) 720 / 670 / 620 600/540480 660/590/530 720 / 670 / 620 600/540480 660/590/530 41 /39 / 37 43/41/39 44/41/39 Thermistor Thermistor Thermistor 0.275(7) 0.275(7) 0.275(7) 19 21 21 2R11C 2R12C 2R12C 2.4 3 3.5 22.4*10.5*22.4 (570*269*570) 29.3*11.5*29.4 (744*292*744) 29.3*11.5*29.4 (744*292*744) 26.4*26.4*1.2(670*670*30) 33.5*33.5*1.2(850*850*30) 33.5*33.5*1.2(850*850*30) 19(41.9) 24(52.9) 24(52.9) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 1/2 (12.7) 1/2 (12.7) 1/2 (12.7) 32 32 32 25.2*13.0*25.2(640*330*640) 32.6*14.4*32.6 (828*365*828) 32.6*14.4*32.6 (828*365*828) 189/378 84/168 84/168
Indoor Unit Type Model Rated Cooling Capacity Rated Heating Capacity Air Circulation H/M/L External Static Pressure Setting temperature range Fan motor Output Model No. of Poles Input Running Current Capacitor Fan Type No. Used / Diameter Fan RPM Cooling(H/M/L) Heating(H/M/L) Noise Level(Sound Press,1m) H/M/L Temperature controller Coil Tube Size (OD) Fins per inch No. of Rows & Column Dehumidification Rate Dimensions (W*H*D) Net Weight Piping Liquid Connection Gas Drain hose (ID ) Packing Dimension (W*H*D) Stuffing Quantity Without S/Parts Front Panel Color "*" Position kcal/hr(W) Btu/hr kcal/hr(W) Btu/hr CMM(CFM) mmAq C W AMNH096BTG0 AMNH126BTG0
Ceiling Concealed Duct AMNH186BTG0 AMNH096BPA0 2268(2637) 9000 2520(2930) 10000 11.5/10/8.5 4 18~30 118 IC-13450LG31A 4 180 4.3 6/370 Sirocco Fan 1/177 1125/990/870 1125/900/870 38/36/34 Thermistor 0.276(7.0) 18 2R14C 1.6 750*300*580(695*56.5*396) 30(6) 1/4(6.35) 3/8(9.52) 25.4(OD) 845*370*760(735*90*435) 228/468 NOBEL WHITE AMNH126BPA0 3024(3516) 12000 3326(3868) 13200 11.5/10/8.5 4 18~30 118 IC-13450LG31A 4 180 4.3 6/370 Sirocco Fan 1/177 1125/990/870 1125/990/870 38/36/34 Thermistor 0.276(7.0) 18 3R14C 2 750*300*580(695*56.5*396) 30(6) 1/4(6.35) 3/8(9.52) 25.4(OD) 845*370*760(735*90*435) 228/468 NOBEL WHITE
2268(2637) 3024(3516) 4536(5274) 9000 12000 18000 2520(2930) 3326(3868) 4990(5802) 10000 13000 19800 8/7/6(282/246/211) 10/9/8(352/317/282) 13.5/12/10(477/424/353) 2 2 2 18~30 / 16~30 18~30 / 16~30 18~30 / 16~30 35 35 47 YDK110-35-4L YDK110-35-4L YSK110-70-4L 4 4 4 68 68 126 0.31 0.31 0.58 2.5/400 2.5/400 2.5/370 Sirocco Fan Sirocco Fan Sirocco Fan 1/7.8(197) 1/7.8(197) 2/7.8(197) 930/840/810 950/850/780 1000/900/800 930/840/810 950/850/780 1000/900/800 34/32/30 37/34/31 38/36/34 Thermistor Thermistor Thermistor 0.276(7.0) 0.276(7.0) 0.276(7.0) 18 18 18 2R,12C 3R,12C 2R, 12C 1 1.2 2 25.6*9.0*21.1(650*230*535) 25.6*9.0*21.1(650*230*535) 39.4*9.0*21.1(1000*230*535) 22(48.5) 22(48.5) 29(63.9) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 3/8 (9.52) 3/8 (9.52) 1/2 (12.7) 25.4 25.4 25.4 29.9*24.6*11.8(760*625*300) 29.9*24.6*11.8(760*625*300) 29.9*24.6*11.8(760*625*300) 172/356 172/356 123/251 -
Note : 1.5 See the page "Combination Table" 2. Due to our policy of innovation some specifications may be changed without notification.
Service Manual 23
4536(5275) 6048(7034) 7560(8792) 9072(10551) 18000 24000 30000 36000 4990(5803) 6653(7737) 8316(9671) 9979(11606) 19800 26400 33000 39600 16.5/14.5/13(583/512/459) 18/16.5/14(636/583/494) 28/25/23(989/883/812) 32/29/26.5(1130/1024/936) 8 8 8 8 18~30 / 16~30 18~30 / 16~30 18~30 / 16~30 18~30 / 16~30 118 118 124 272 IC-13450LG13C IC-13450LG13C IC-13450LG13J IC-13450LG13A 4 4 4 4 180 180 250 323 0.92 0.92 1.1 1.42 6/370 6/370 6/370 6/370 Sirocco Fan Sirocco Fan Sirocco Fan Sirocco Fan 2/6.97(177) 2/6.97(177) 2/6.97(177) 2/6.97(177) 1356/-/1270 1417/1350/1255 1415/1360/1290 1415/1360/1290 1356/-/1270 1417/1350/1255 1415/1360/1290 1415/1360/1290 36/34/32 37/35/33 40/38/36 42/40/38 Thermistor Thermistor Thermistor Thermistor 0.275(7) 0.275(7) 0.275(7) 0.275(7) 21 21 21 21 3R10C 3R10C 3R 12C 3R 12C 2.0 2.5 3 3.5 34.6*10.2*17.7 (880*260*450) 34.6*10.2*17.7 (880*260*450) 46.4*11.7*17.7(1180*298*450) 46.4*11.7*17.7(1180*298*450) 35(77.2) 35(77.2) 38(83.8) 38(83.8) 1/4(6.35) 1/4(6.35) 1/4(6.35) 1/4(6.35) 1/2(12.7) 1/2(12.7) 5/8(15.88) 5/8(15.88) 25.4(OD) 25.4(OD) 25.4(OD) 25.4(OD) 44.7*13.4*23.0(1135*340*585) 44.7*13.4*23.0(1135*340*585) 18.5*14.8*23.0(1435*375*585) 18.5*14.8*23.0(1435*375*585) 120/252 120/252 95/191 95/191 Ceiling & Floor(Convertible) AMNH126VEA0 AMNH186VBA0 AMNH246VBA0
2268(2637) 3024(3516) 4536(5274) 6048(7032) 9000 12000 18000 24000 2520(2930) 3326(3867) 4990(5801) 6350(7384) 10000 132000 19800 25200 7.8/6.4/5.0(276/226/177) 10.0/8.3/6.5(353/293/230) 135./12/11(477/424/388) 15/13.5/12(530/477/424) 18-30/16-30 18-30/16-30 18~30 / 16~30 18~30 / 16~30 14.5 17.5 30 35 IC-18422LG31B IC-18422LG31A IC-9430LGCM IC-9430LGCM 4 4 4 4 35 43 53 63 0.18 0.23 0.23 0.27 1.5/370 1.5/370 1.5/370 1.5/370 Cross Flow Fan Cross Flow Fan Cross Flow Fan Cross Flow Fan 1/3.7(95) 1/3.7(95) 1/3.1(80) 1/3.1(80) 960/870/760 1240/1120/900 1090/990/890 1160/1060/960 960/870/760 1240/1120/900 1090/990/890 1160/1060/960 36/32/28 40/36/31 43 / 40 / 37 45 / 42 / 39 Thermistor Thermistor Thermistor Thermistor 0.197(5) 0.197(5) 0.275(7) 0.275(7) 20 20 18 20 2R 12C 2R 12C 2R 12C 2R 14C 1 1.2 2.3 3.2 35.4*7.9*19.3 (900*200*490) 35.4*7.9*19.3 (900*200*490) 47.24*24.21*8.07(1200*615*205) 47.24*24.21*8.07(1200*615*205) 12(26.5) 12(26.5) 30(66.1) 30(66.1) 1/4 (6.35) 1/4 (6.35) 1/4(6.35) 1/4(6.35) 3/8 (9.52) 3/8 (9.52) 1/2(12.7) 1/2(12.7) 20 20 20 20 38.2*11.2*22.2 (970*285*565) 38.2*11.2*22.2 (970*285*565) 50*10.9*27(1272*278*686) 50*10.9*27(1272*278*686) 189/383 189/383 102/219 102/219
Note : 1.5 See the page "Combination Table" 2. Due to our policy of innovation some specifications may be changed without notification.
380~1450/450~1350 420~2400/480~2600 420~2400/480~2600 440~2970/560~2950 440~2970/560~2950 450~3580/620~3580 3.08~13.0/4.6~12.9 3.08~13.0/4.6~12.9 28 1,220~240,50 94~98 3 e-Scroll Rotary MRA99150-9090 R-410A L.E.V 0.276(7.0) 18 2R,36C IC28640LG28J 130 6/370 Propeller 1/18.1(460) Side Discharge 53(1872) 51/48 Invertion cycle 1/4 (6.35)*3EA 3/8 (9.52)*3EA 34.3*31.5*12.6 (870*808*320) 75(165) 3*2.5 4*0.75 (Includes earth) 50 25 15 7.5 54/114 28 1,220~240,50 94~98 4 e-Scroll Rotary MRA99150-9090 R-410A L.E.V 0.276(7.0) 18 2R,36C IC28640LG28J 130 6/370 Propeller 1/18.1(460) Side Discharge 53(1872) 51/48 Invertion cycle 1/4 (6.35)*4EA 3/8 (9.52)*4EA 34.3*31.5*12.6 (870*808*320) 75(165) 3*2.5 4*0.75 (Includes earth) 50 25 15 7.5 54/114
1650(59.97) at 7.5m 1650(59.97) at 7.5m 1650(59.97) at 7.5m 1950(68.78) at 7.5m 1950(68.78) at 7.5m 2500(88.18) at 7.5m
Notes: 1. Capacities are based on the following conditions: Cooling: - Indoor Temperature 27C(80.6F) DB /19C(66.2F) WB Heating: - Indoor Temperature 20C(68F) DB / 15C(59F) WB - Outdoor Temperature 35C(95F) DB /24C(75.2F) WB - Outdoor Temperature 7C(44.6F) DB / 6C(42.8F) WB - Interconnecting Piping Length 7.5m - Interconnecting Piping Length 7.5 m - Level Difference of Zero. - Level Difference of Zero. 2. Capacities are Net Capacities. 3. 5 : See the page "Combination Table" 4. Due to our policy of innovation some specifications may be changed without notification.
Service Manual 25
Notes: 1. Capacities are based on the following conditions: Cooling: - Indoor Temperature 27C(80.6F) DB /19C(66.2F) WB Heating: - Indoor Temperature 20C(68F) DB / 15C(59F) WB - Outdoor Temperature 35C(95F) DB /24C(75.2F) WB - Outdoor Temperature 7C(44.6F) DB / 6C(42.8F) WB - Interconnecting Piping Length 7.5m - Interconnecting Piping Length 7.5 m - Level Difference of Zero. - Level Difference of Zero. 2. Capacities are Net Capacities. 3. 5 : See the page "Combination Table" 4. Due to our policy of innovation some specifications may be changed without notification.
Service Manual 27
Installation
Installation
Read completely, then follow step by step.
unit. There should not be any obstacles to prevent the air circulation. A place where air circulation in the room will be good. A place where drainage can be easily obtained. A place where noise prevention is taken into consideration. Do not install the unit near the door way. Ensure the spaces indicated by arrows from the wall, ceiling, fence, or other obstacles.
Connecting cable
Drain hose
More than 2m
Installation
CAUTION
Install the indoor unit on the wall where the height from the floors more than 2.3 meters.
Top view
(unit: mm)
The place where the unit shall be leveled. The place shall allow easy water drainage.(Suitable dimension H is necessary to get a slope to drain as figure.) The place shall easily connect with the outdoor unit. The place where the unit is not affected by an electrical noise. The place where air circulation in the room will be good . There should not be any heat source or steam near the unit
600
Front
Front view
100 or more
50 or more
Floor
Service Manual 29
Installation
(Ceiling installation)
(Floor/Wall installation)
Installation
How to fix
1. Room Type Indoor Unit Installation
The mounting wall should be strong and solid enough to protect it from the vibration. 1) Mount the installation plate on the wall with four Type "A" screws. (If mounting the unit on the concrete wall, consider using anchor bolts.) Always mount the Installation plate horizontally by aligning the marking-off line by means of the thread and a level. 2) Drill the piping hole with 70mm dia. holecore drill. Line according to the arrows marked on lower the left and the rght side of the Installation Plate. The meeting point of the extended line is the center of the hole. Drill the piping hole at either the right or the left and the hole should be slightly slant to the outdoor side.
Installation Plate
Installation plate
D
70mm
A
Right rear piping
Service Manual 31
B
70mm
Installation
2) Cover pipe and cover side remove Remove two screws(for fixing cover pipe) Pull up the cover side of desired connecting direction, then cover side is separated. In case connecting direction is left or right, path through the hole of cover side.
CAUTION: After removing the pipe hole, cut the burr for safety.
Pipe hole
NOTE: When connecting pipe path through rear wall, dont remove the hole. 3) Drain hose junction Remove the rubber stopple of desired drain direction. As the following picture, Insert drain hose in the handle of drain pan, and join drain hose and connecting hose.
Installation s Sticking the installation guide map and fixing Indoor unit
1. Put an Installation Guide Map on the desired surface.
INSTALLATION GUIDE MAP
7. Drill the piercing part for connecting pipe as diameter 50mm. (In case of piercing rear surface)
2. Make a hole with diameter of 6mm and depth of 30-35mm when piercing a screw point.
IN ST AII AT IO N GU ID EM AP
8. First, Drive the two points of the upper parts by screws. (Leave 10mm for hanging product)
mm
10
IN ST AL LA TIO N
GU
GU ID EM AP
9. Drive the lower parts after facing the hole of product with plastic anchors, and fix completely the upper screws.
Plastic anchors
Plastic anchors
4. Hang the hole of product at the upper screws. (In this time, Remove the map)
(Falling attention)
INS TAL LAT ION GUID EM AP
In case of nothing wrong in the matter, connect the pipe and the wire. (Installation manual reference)
6. Look at suited horizon by horizontal meter on the horizontal setting line, and Fix lightly the map by adhesive tape.
GU ID EM AP
Service Manual 33
5-7mm
Horizontality
(0.2~0.3")
IN ST AL LA TIO N
Installation
3). Drill a hole in the wall Drill the piping hole with a 70mm hole core drill. Drill the piping hole at either the right or the left with the hole slightly slanted to the outdoor side.
2) Measure the wall and mark the centerline. It is also important to use caution concerning the location of the installation plate-routing of the wiring to power outlets is through the walls typically. Drilling the hole through the wall for piping connections must be done safely. (SU)
C
Installation plate
D
70mm
A
Right rear piping
(SZ)
Installation plate
D C
Left rear piping
70mm
A
Right rear piping
(3/16"~5/16")
5-7mm
Installation
A B
CASE 1
POSITION OF SUSPENSION BOLT Apply a joint-canvas between the unit and duct to absorb unnecessary vibration. Apply a filter Accessory at air return hole. (Unit:mm)
Dimension A B C D E F (G) H I Capacity 18k, 24k 932 880 355 45.5 450 30 87 750 163
Install the unit leaning to a drainage hole side as a figure for easy water drainage.
H
Drainage hole
CASE 2
POSITION OF CONSOLE BOLT A place where the unit will be leveled and that can support the weight of the unit. A place where the unit can withstand its vibration. A place where service can be easily performed.
M10 Nut X4 (Local M10 SP. washer X 4 supply) M10 washer X4
NOTE:
Throughly study the following installation locations: 1. In such places as restaurants and kitchens, considerable amount of oil steam and flour adhere to the fan, the fin of the heat exchanger, resulting in heat exchange reduction, spraying, dispersing of water drops, etc. In these cases, take the following actions: Make sure that the ventilation fan for smoke-collecting hood on a cooking table has sufficient capacity so that it draws oily steam which should not flow into the suction of the air conditioner. Make enough distance from a cooking room to install the air conditioner in such a place where it may not suck in oil steam. 2. Avoid installing air conditioner in such circumstances where cutting oil mist or iron powder is in suspension in factories, etc. 3. Avoid places where inflammable gas is generated, flows in, is stored or vented. 4. Avoid places where sulfurous acid gas or corrosive gas is generated. 5. Avoid places near high frequency generators.
M10 washer
X4
Service Manual 35
1-3 mm
87 830 186
(G)
C E
Installation
- BT chassis
Install the unit above the ceiling correctly.
A B
CASE 1
POSITION OF SUSPENSION BOLT Apply a joint-canvas between the unit and duct to absorb unnecessary vibration. Apply a filter Accessory at air return hole. (Unit:mm)
Dimension Capacity 9/12K 18K A 708 B 678 C 434 D 51 51 E 537 535 F G H 172 175
Install the unit leaning to a drainage hole side as a figure for easy water drainage.
F
Drainage hole
CASE 2
POSITION OF CONSOLE BOLT A place where the unit will be leveled and that can support the weight of the unit. A place where the unit can withstand its vibration. A place where service can be easily performed.
M10 Nut
X4
M10 washer
X4
1-3 mm
G H
C E
Installation
C A
- BP chassis
Install the unit above the ceiling correctly.
G H
CASE 1
POSITION OF SUSPENSION BOLT Apply a joint-canvas between the unit and duct to absorb unnecessary vibration. Apply a filter Accessory at air return hole. (Unit:mm)
Capacity Dimension
9k/12k BTU/h 633 580 695 660 750 45 369 797 20 232 372
Install the unit leaning to a drainage hole side as a figure for easy water drainage.
H
Drainage hole
CASE 2
POSITION OF CONSOLE BOLT A place where the unit will be leveled and that can support the weight of the unit. A place where the unit can withstand its vibration. A place where service can be easily performed.
M10 Nut
M10 washer
X4
Service Manual 37
1-3 mm
D E
Installation
Pipe cutter
90
Slanted
Rough
Pipe
2) Remove burrs. Remove burrs from cut edges of pipes. Turn the pipe end toward down to avoid the metal powder entering the pipe.
Reamer
CAUTION: If burrs are not removed, they may cause a gas leakage.
Point down
3) Flaring the pipes. Insert the flare nuts, mounted on the connection ports of both indoor and outdoor unit, onto the copper pipes. Some refrgerant gas may leak, when the flare nuts are removed from the indoor unit, as some gas is charged to prevent the inside of the pipe from rusting. Fit the copper pipe end into the Bar of flare tool about 0~0.5mm higher. (See illustration) Flare the pipe ends. 4) Tape the flaring portion to protect it from the dust or damages.
"A": 15.88 mm (5/8") 0~1.0 mm 12.7 mm (1/2") 0~0.5 mm 9.52 mm (3/8") 0~0.5 mm 6.35 mm (1/4") 0~0.5 mm
Bar Bar
Copper pipe
"A"
Clamp handle
= Improper flaring =
Inclined
Surface damaged
Cracked
Uneven thickness
When properly flared, the internal surface flare will evenly shine and be of even thickness. Since the flare part comes into contact with the connectors, carefully check the flare finish.
Installation
Tubing holder
Drain hose
To remove the holder, press the bottom of chassis near the holder upward and pull the tab out of its hole.
2 Pull 1 Press
NOTE: If the drain hose is routed inside the room, insulate the hose with an insulation material* so that dripping from "sweating"(condensation) will not damage furniture or floors. *Foamed polyethylene or equivalent is recommended. 4. Indoor unit installation Hook the indoor unit onto the upper portion of the installation plate.(Engage the two hooks of the rear top of the indoor unit with the upper edge of the installation plate.) Ensure that the hooks are properly seated on the installation plate by moving it left and right.
CAUTION When install, make sure that the remaining parts must be removed clearly so as not to damage the piping and drain hose, especially power cord and connecting cable.
Connecting cable
Drain hose
Press the lower left and right sides of the unit against the installation plate until the hooks engage into their slots(clicking sound). 5. Connecting the pipings to the indoor unit and drain hose to drain pipe.
Drain hose
Align the center of the pipings and sufficiently tighten the flare nut by hand.
2. Insert the connecting cable into the indoor unit from the outdoor unit through the piping hole. Do not connect the cable to the indoor unit. Make a small loop with the cable for easy connection later.
Flare nut
Pipings
Service Manual 39
Installation
When extending the drain hose at the indoor unit, install the drain pipe.
Drain pipe
6. Wrap the insulation material around the connecting portion. Overlap the connection pipe insulation material and the indoor unit pipe insulation material. Bind them together with vinyl tape so that there is no gap.
Plastic bands Insulation material
2. Insert the piping, drain hose and the connecting cable into the piping hole.
3. Insert the connecting cable into the indoor unit. Don't connect the cable to the indoor unit. Make a small loop with the cable for easy connection later. 4. Tape the drain hose and the connecting cable. Connecting cable
Connection pipe Vinyl tape (wide) Connecting cable Indoor unit pipe Wrap with vinyl tape
Wrap the area which accommodates the rear piping housing section with vinyl tape.
5. Indoor unit installation Bundle the piping and drain hose together by wrapping them with vinyl tape over the range within which they fit into the rear piping housing section.
Wrap with vinyl tape Pipe
Hang the indoor unit from the hooks at the top of the installation plate. Insert the spacer etc. between the indoor unit and the installation plate and separate the bottom of the indoor unit from the wall.
Installation
6) Connecting the pipings to the indoor unit and the drain hose to drain pipe. Align the center of the pipings and sufficiently tighten the flare nut by hand. 8) Reroute the pipings and the drain hose across the back of the chassis.
Flare nut
When extending the drain hose at the indoor unit, install the drain pipe.
Drain hose
9) Set the pipings and the drain hose to the back of the chassis with the tubing holder. Hook the edge of tubing holder to tap on chassis and push the bottom of tubing holder to be engaged at the bottom of chassis.
7) Wrap the insulation material around the connecting portion. Overlap the connection pipe heat insulation and the indoor unit pipe heat insulation material. Bind them together with vinyl tape so that there is no gap.
Plastic bands Insulation material 1 Hook 2 Push
Tubing holder
Wrap the area which accommodates the rear piping housing section with vinyl tape.
Connection pipe Vinyl tape (wide) Indoor unit piping Wrap with vinyl tape
10) Indoor unit installation Remove the spacer. Ensure that the hooks are properly seated on the installation plate by moving it left and right.
Connecting cable
Bundle the piping and drain hose together by wrapping them with cloth tape over the range within which they fit into the rear piping housing section. Pipe
Drain hose Vinyl tape (narrow)
Press the lower left and right sides of the unit against the installation plate until the hooks engage into their slots(clicking sound).
Service Manual 41
Drain pipe
4) Wrap the insulation material around the connecting portion. Overlap the connection pipe insulation material and the indoor unit pipe insulation material. Bind them together with vinyl tape so that there is no gap.
Plastic bands Insulation material
Loop
NOTE: If the drain hose is routed inside the room, insulate the hose with an insulation material* so that dripping from "sweating"(condensation) will not damage furniture or floors. *Foamed polyethylene or equivalent is recommended.
Wrap the area which accommodates the rear piping housing section with vinyl tape.
3) Connecting the pipings to the indoor unit and drain hose to drain pipe. Align the center of the pipes and sufficiently tighten the flare nut by hand.
Connecting cable
Flare nut
Pipes
Bundle the piping and drain hose together by wrapping them with vinyl tape for enough to cover where they fit into the rear piping housing section.
Wrap with vinyl tape Pipe
Flare nut Wrench Indoor unit tubing Connection pipe Vinyl tape(wide) Drain hose
2. Assemble connecting lead wire with controller and first fix the upper part of panel front, then match the lower part of panel front
Service Manual 43
Connecting cable
Drain hose
Press the lower left and right sides of the unit against the installation plate until the hooks engage into their slots(clicking sound). 4. Connecting the pipings to the indoor unit and drain hose to drain pipe. Align the center of the pipes and sufficiently tighten the flare nut by hand.
Drain hose
Flare nut
Pipes
2. Insert the connecting cable into the indoor unit from the outdoor unit through the piping hole. Do not connect the cable to the indoor unit. Make a small loop with the cable for easy connection later. 3. Tape the tubing, drain hose, and the connecting cable. Be sure that the drain hose is located at the lowest side of the bundle. Locating at the upper side can cause drain pan to overflow inside the unit.
Open-end wrench (fixed) Flare nut Wrench Indoor unit tubing Connection pipe
When extending the drain hose at the indoor unit, install the drain pipe.
Connecting cable
Installation
5. Wrap the insulation material around the connecting portion. Overlap the connection pipe insulation material and the indoor unit pipe insulation material. Bind them together with vinyl tape so that there is no gap.
Plastic bands Insulation material
4. Tape the drain hose and the connecting cable. Connecting cable
Wrap the area which accommodates the rear piping housing section with vinyl tape.
Connection pipe Vinyl tape Wrap with vinyl tape (wide) Connecting cable Indoor unit pipe
5. Indoor unit installation Hang the indoor unit from the hooks at the top of the installation plate. Insert the spacer etc. between the indoor unit and the installation plate and separate the bottom of the indoor unit from the wall.
Indoor unit Spacer
Pipe
Installation plate
Vinyl tape(narrow)
8cm
Bundle the piping and drain hose together by wrapping them with vinyl tape for enough to cover where they fit into the rear piping housing section.
Wrap with vinyl tape Pipe
6. Connecting the pipings to the indoor unit and the drain hose to drain pipe. Align the center of the pipes and sufficiently tighten the flare nut by hand.
Flare nut
Pipes
2. Insert the piping, drain hose, and the connecting cable into the piping hole.
When extending the drain hose at the indoor unit, install the drain pipe.
Drain hose
3. Insert the connecting cable into the indoor unit. Don't connect the cable to the indoor unit. Make a small loop with the cable for easy connection later.
Service Manual 45
Installation
7. Wrap the insulation material around the connecting portion. Overlap the connection pipe heat insulation and the indoor unit pipe heat insulation material. Bind them together with vinyl tape so that there is no gap.
Plastic bands Insulation material
9. Set the pipings and the drain hose to the back of the chassis with the tubing holder. Hook the edge of tubing holder to tap on chassis and push the bottom of tubing holder to be engaged at the bottom of chassis.
Tubing holder
Wrap the area which accommodates the rear piping housing section with vinyl tape.
Connection pipe Vinyl tape (wide) Wrap with vinyl tape Pipe Vinyl tape(narrow) Connecting cable Indoor unit piping
10. Indoor unit installation Remove the spacer. Ensure that the hooks are properly seated on the installation plate by moving it left and right.
Connecting cable
Drain hose
Bundle the piping and drain hose together by wrapping them with cloth tape over the range within which they fit into the rear piping housing section.
Pipe Drain hose Vinyl tape(narrow)
Press the lower left and right sides of the unit against the installation plate until the hooks engage into their slots(clicking sound).
8. Reroute the pipings and the drain hose across the back of the chassis.
Installation
CAUTION
Bad case s Following bending type from right to left could cause problem of pipe damage.
Installation Information (For left piping) Good case For left piping. Follow the instruction below. Press on the upper side of clamp. ( )
Service Manual 47
Installation
Old building
Insert the set anchor and washer onto the suspension bolts for locking the suspension bolts on the ceiling. Mount the suspension bolts to the set anchor firmly. Secure the installation plates onto the suspension bolts (adjust level roughly) using nuts, washers and spring washers.
New building
Installation
Install Plate
Inlet hanger
R
1)
Before secure the Installation Plates, select the bent direction of the Installion Plate to the inside or the outside according to the installation circumstances.
Suspension bolt
2)
1236
Drill the piping hole on the wall slightly tilted to the outdoor side using a 70 hole-core drill.
Indoor
WALL
Outdoor 5~7mm
Service Manual 49
Installation
Insert the nuts and washer onto the suspension bolts for locking the suspension bolts on the ceiling. Mount the suspension bolts to the anchor-nuts firmly. Secure the Installation plates onto the Suspension bolts (adjust level roughly.) using nuts, washers and spring washers.
1)
Nut
Washer
Suspension bolts
max. 12mm
Washer
2)
Engage 2 hooks on the both left and right side of the unit to the lower slot of Installation Plates. Adjust a level with a level gauge on the direction of left-right, back-forth by adjusting suspension bolts. Move the hooks on the unit to the upper slot of Installation Plates. Then the unit will be declined to the bottomside so as to drain well.
Suspension bolt
Adjust a level
Installation plate
Upper slot
Installation
- VE chassis
The wall you select should be strong and solid enough to prevent vibration 1. Mount the installation plate on the wall with type "A" screws. If mounting the unit on a concrete wall, use anchor bolts. Mount the installation plate horizontally by aligning the centerline using a level.
Type "A" screw Installation Plate
2. Measure the wall and mark the centerline. It is also important to use caution concerning the location of the installation plate-routing of the wiring to power outlets is through the walls typically. Drilling the hole through the wall for piping connections must be done safely.
Installation plate
D
70mm
A
Right rear piping
CHASSIS (Grade) VE
Installation plate
A B
B
70mm
70mm
Service Manual 51
Installation
Secure the Installation plates onto the Suspension bolts (adjust level roughly.) using nuts, washers and spring washers. Engage 2 hooks on the both left and right side of the unit to the lower slot of Installation Plates. Adjust a level with a level gauge on the direction of left-right, back-forth by adjusting suspension bolts. Move the hooks on the unit to the upper slot of Installation Plates. Then the unit will be declined to the bottomside so as to drain well.
Washer
235 820
Suspension bolt
Washer
(3/16"~5/16")
5-7mm
Installation
1. Install declination of the indoor unit is very important for the drain of the convertible type air conditioner. 2. Minimum thickness of the insulation for the connecting pipe shall be 7mm. 3. If the Installation Plates are fixed to horizontal line, the indoor unit after installing will be declined to the bottomside.
Front of view
The unit must be horizontal or declined to the drain hose connected when finished installation.
Ceiling
Side of view
The unit must be declined to the bottomside of the unit when finished installation.
Ceiling
Service Manual 53
Installation
Secure the unit to the Installation Plates with four M8 bolts and washers.
Fit the projection hooks of the side plates to the 'Side Panel' and the 'Front Panel' by lifting it. Fasten the screws.
2
265
Drill the piping hole on the wall slightly tilted to the outdoor side using a 70 hole-core drill.
Wall Indoor Outdoor
Secure the 'Install Plate' onto the wall with four anchor bolts, washers and spring washers.
Spring washer
Wall
Nut
Before secure the Install Plates, select the bent direction of the 'Install Plate' to the inside or outside according to the installation circumstances.
123
Service Manual 55
5~7mm
Installation
Install the Indoor unit onto Installation Plate. Insert 2 hooks on the both left and right side of the unit to the inner slot (wall side) of the Installation Plate. Secure the unit to the Installation Plate with four M8 bolts and washers.
Inner slot
Fit the projection hooks of the side plates to the 'Side Panel' and the 'Front Panel' by lifting it. Fasten the screws.
From the left wall more than 760mm From the right wall more than 840mm
448mm
Drill the piping hole with 70mm dia, hole core drill. Piping hole should be slightly slant to the outdoor side.
After Installing, reassemble detached parts. Hang the 'Inlet Grille' and hook the 'Inlet Hanger' to the Hanger Screw. Assemble the 'Side Plates(R,L)' with 2 screws on both left and right side.
Slot Wall
Service Manual 57
5~7mm
- TC chassis
1) Ceiling opening dimensions and hanging bolt location
The dimensions of the paper model for installing are the same as those of the ceiling opening dimensions.
1,000 (Ceiling opening) 931.6 893.4 (Hanging bolt) 860 430 (Ceiling opening) 390
328.4 (Hanging bolt) 30.8
CAUTION This air-conditioner uses a drain pump. Install the unit horizontally using a level gauge. During the installation, care should be taken not to damage electric wires. Select and mark the position for fixing bolts and piping hole. Decide the position for fixing bolts slightly tilted to the drain direction after considering the direction of drain hose. Drill the hole for anchor bolt on the wall.
Ceiling board
NOTE:
Avoid the following installation location. 1. Such places as restaurants and kitchen where considerable amount of oil steam and flour is generated. These may cause heat exchange efficiency reduction, or water drops, drain pump mal-function. In these cases, take the following actions; Make sure that ventilation fan is enough to cover all noxious gases from this place. Ensure enough distance from the cooking room to install the air conditioner in such a place where it may not suck oily steam.
Air conditioner
Take enough distance Use the ventilation fan for smoke-collecting hood with sufficient capacity. Cooking table
2. Avoid installng air conditioner in such places where cooking oil or iron powder is generated. 3. Avoid places where inflammable gas is generated. 4. Avoid place where noxious gas is generated. 5. Avoid places near high frequency generators.
Installation
Ceiling board
Set screw of paper model (4 pieces) Open the ceiling board along the outer edge of the paper model
The following parts are local purchasing. Hanging Bolt - W 3/8 or M10 Nut - W 3/8 or M10 Spring Washer - M10 Plate Washer - M10
Drill the piping hole on the wall slightly tilted to the outdoor side using a 70 hole-core drill.
CAUTION Tighten the nut and bolt to prevent unit from falling off.
Service Manual 59
5~7mm
103mm
- TE/TF/TD chassis
1) Ceiling opening dimensions and hanging bolt location
The dimensions of cardboard for installing are the same as those of the ceiling opening dimensions.
600 (Ceiling opening) 39.5 521(Hanging bolt) 39.5
TE
Level gauge
CAUTION This air-conditioner uses a drain pump. Install the unit horizontally using a level gauge. During the installation, be careful not to damage electric wires.
790 (Ceiling opening) 109 572(Hanging bolt)
75
109
Ceiling
Unit:mm
Select and mark the position for fixing bolts and piping hole. Decide the position for fixing bolts slightly tilted to the drain direction after considering the direction of drain hose. Drill the hole for anchor bolt on the wall.
Ceiling board
66
Unit:mm
Unit:mm
TF
TD
Installation
NOTE:
Avoid the following installation location. 1. Such places as restaurants and kitchen where considerable amount of oil steam and flour is generated. These may cause heat exchange efficiency reduction, or water drops, drain pump mal-function. In these cases, take the following actions; Make sure that ventilation fan is enough to cover all noxious gases from this place. Ensure enough distance from the cooking room to install the air conditioner in such a place where it may not suck oily steam.
Air conditioner
Take enough distance Use the ventilation fan for smoke-collecting hood with sufficient capacity. Cooking table
2. Avoid installng air conditioner in such places where cooking oil or iron powder is generated. 3. Avoid places where inflammable gas is generated. 4. Avoid place where noxious gas is generated. 5. Avoid places near high frequency generators.
Ceiling board
Set screw of cardboard (4 pieces) Open the ceiling board along the outer edge of the paper model
The following parts are local purchasing. Hanging Bolt - W 3/8 or M10 Nut - W 3/8 or M10 Spring Washer - M10 Plate Washer - M10
Drill the piping hole on the wall slightly tilted to the outdoor side using a 70 hole-core drill.
CAUTION
Service Manual 61
5~7mm
Tighten the nut and bolt to prevent the unit from falling off.
150mm
Installation
el
ow er
pa
rt
Fix the cord clamps on the wall by 3 tapping screws (accessory). Fix the remote control cord.
Screw (accessory)
ELECTRICAL WIRING
(Main board)
CN REMO
Remote controller
Wire and make sure that teminal numbers are matched on unit side and remote controller side. The maximum length of the cord is 100m. If the length of the cord exceeds 50m, 2 use a wire size greater than 0.5mm .
HOW TO INSERT BATTERIES Remove the battery cover from the remote controller. Slide the cover according to the arrow direction. Insert the two batteries. Be sure that the (+) and (-) directions are correct. Be sure that both batteries are new. Re-attach the cover. Slide it back into position.
Do not use rechargeable batteries, such batteries differ from standard dry cells in shape, dimensions, and performance. Romove the batteries from the remote controller if the air conditioner is not going to be used for some long time.
Service Manual 63
Installation
Connector
3) Finally, tighten the flare nut with torque wrench until the wrench clicks. s When tightening the flare nut with torque wrench, ensure the direction for tightening follows the arrow on the wrench.
Outdoor unit
*Connecting pipe size Indoor Units 7K/9K/12K 18K/24K 30K/36K Gas side 9.52(3/8) 12.7(1/2) 15.88(5/8) Liquid side 6.35(1/4) 6.35(1/4) 6.35(1/4)
Torque wrench
CAUTION: After the confirmation of the above conditions, prepare the wiring as follows:
1) Never fail to have an individual power specialized for the air conditioner. As for the method of wiring, be guided by the circuit diagram pasted on the inside of control box cover. 2) The means for disconnection from a power supply shall be incorporated in the fixed wiring and have an air gap contact separation of at least 3mm in each active(phase) conductors. 3) The screw which fasten the wiring in the casing of electrical fittings are liable to come loose from vibrations to which the unit is subjected during the course of transportation. Check them and make sure that they are all tightly fastened. (If they are loose, it could give rise to burn-out of the wires.) 4) Specification of power source. 5) Confirm that electrical capacity is sufficient. 6) See to that the starting voltage is maintained at more than 90 percent of the rated voltage marked on the name plate. 7) Confirm that the cable thickness is as specified in the power sources specification. (Particularly note the relation between cable length and thickness.) 8) Never fail to equip a leakage breaker where it is wet or moist. 9) The following troubles would be caused by voltage drop-down. Vibration of a magnetic switch, damage on the contact point there of, fuse breaking, disturbance to the normal function of a overload protection device. Proper starting power is not given to the compressor.
Installation
CAUTION: If a power plug is not to be used, provide a circuit breaker between power source and the unit as shown below.
Main power source
Circuit Breaker
Air Conditioner
18k~30k Btu
Circuit Breaker Use a 30A circuit breaker or time delay fuse.
CAUTION
The power cord connected to the outdoor unit should be complied with the following specifications (Rubber insulation, type H05RN-F approved by HAR or SAA).
8.5mm
The connecting cable connected to the indoor and outdoor unit should be complied with the following specifications (Rubber insulation, type H07RN-F approved by HAR or SAA).
7.5mm
GN
/YL 20
NORMAL CROSS SECTIONAL AREA 3.5mm2 (18k~30k Btu) 5.0mm2 (31k~56k Btu)
mm
GN
/YL 20
Service Manual 65
Installation
Screw
Pull the right and the left side.
2) Check the drainage Pour a glass of water on the evaporator. Ensure if water flows drain hose of indoor unit without any leakage.
Installation
3) Drain piping The drain hose should point downward for easy drain flow.
Downward slope
Inlet Grille
Water leakage
2) To check the drainage. Pour a glass of water on the evaporator. Ensure the water flows through the drain hose of the indoor unit without any leakage and goes out the drain exit.
Connecting area drain hose
Water leakage
Waving
Leakage checking
Ditch
Service Manual 67
Installation
Drain piping
1. The drain hose should point downward for easy drain flow.
Downward slope
Do not raise
Water leakage
Water leakage
Waving
Ditch
Installation
Front of view The unit must be horizontal or declined to the drain hose connected when finished installation.
Ceiling
1~3mm
CORRECT
Drainage hole
INCORRECT
Drainage hole
Lay the drain hose with a downware inclination so water will drain out.
Thermal insulator (Local supply) Drainage pipe (Local supply)
Unit
Drainage hole
700mm
CORRECT
B C U-Trap A
Install the P-Trap (or U-Trap) to prevent a water leakage caused by the blocking of intake air filter.
Service Manual 69
Installation
1/50~1/100
MAX 700mm
Drain test
The air conditioner uses a drain pump to drain water. Use the following procedure to test the drain pump operation:
Feed water
Drain Pump
Connect the main drain pipe to the exterior and leave it provisionally until the test comes to an end. Feed water to the flexible drain hose and check the piping for leakage. Be sure to check the drain pump for normal operating and noise when electrical wiring is finished. When the test is completed, connect the flexible drain hose to the drain port on the indoor unit.
Drain pan
Installation
[Outdoor Unit]
[Indoor Unit] A
B 15m C 7.5m
Max piping length each indoor unit B 25m 25m 25m C 25m 25m D 25m
3/8"(9.52mm) 1/2"(12.7mm)
1/4"(6.35mm) 1/4"(6.35mm)
7.5m 7.5m
25m 25m
25g/m 35g/m
Service Manual 71
Installation
BD Unit
L1 L2
Place the BD unit and indoor units within a level distance of 10m from each other.
L3 30m B
BD Unit
L4 L5
10m
Total main piping length : 50m( A + B ) Total branch piping length : 50m(L1+L2+ L3+L4 +L5+L6) Each branch piping length : 15m(L1,L2,L3,L4 ,L5,L6) Total system piping length : 100m(40+60)
R
BD Unit
Place the BD unit and indoor units within a level distance of 10m from each other.
10m
Installation
A7UW486FA0 Outdoor Unit
BD Unit
L1 L2
L3 30m B
BD Unit
L4 L5
10m
L7
Total main piping length : 50m( A + B ) Total branch piping length : 60m( L1+L2+ L3+L4 +L5+L6 +L7) Each branch piping length : 15m( L1,L2,L3,L4 ,L5,L6 ,L7) Total system piping length : 110m(50+60)
R
BD Unit
Place the BD unit and indoor units within a level distance of 10m from each other.
10m
BD Unit
30m
Outdoor Unit
Service Manual 73
Installation
A8UW486FA0 Outdoor Unit
BD Unit
L1 L2 L3 L4
30m
BD Unit
L5 L6
10m
L8
Total main piping length : 50m( A + B ) Total branch piping length : 70m(L1+L2+ L3+L4 +L5+L6 +L7 +L8) Each branch piping length : 15m(L1,L2,L3,L4 ,L5,L6 ,L7 ,L8) Total system piping length : 120m(50+70) R BD Unit
Place the BD unit and indoor units within a level distance of 10m from each other.
10m
Installation
A B
= + +
Total Main pipe length - rated length 7,9,12 k Branch pipe length - rated length 18,24 k Branch pipe length - rated length ( Rated length = 5m)
a 7k
b 9k
c 9k
d 9k
e 18k
= A + B Total main pipe(A+B+C) = 30m Each branch pipe(a, b, c, d, e) = 10m Additional Charge = (30-5) x 50 + (10-5) x 20 x 4 + (10-5) x 30 = 1800g
Caution
Regulation for refrigerant leakage(in Europe) : the amount of refrigerant leakage should satisfy the following equation for human safety. Total amount of refrigerant in the system Volume of the room at which indoor unit of the least capacity is installed
0.3 ( kg / m3 )
If the above equation can not be satisfied, then follow the following steps. - Selection of air conditioning system: select one of the next 1. Effective opening part Installation 2. Reconfirmation of outdoor unit capacity and piping length 3. Reduction of the amount of refrigerant 4. 2 or more security device installation of alarm for gas leakage - Change indoor unit type : installation position should be over 2m from the floor (Wall mounted type Cassette type) - Adoption of ventilation system : choose ordinary ventilation system or building ventilation system - Limitation in piping work : design for earthquake-proof and prevention against thermal stress
Service Manual 75
BD Unit
A A
A6UW406FA0
Y-Branch
CAUTION
Capacity is based on standard length and maximum allowance length is on the basis of reliability. Oil trap should be installed every 5~7 meters.
Installation
Gas Pipe
Liquid Pipe
19.05
19.05 19.05
9.52
9.52 9.52
Y branch
A To Outdoor Unit A B B To BD Unit
Ensure that the branch pipes are attached horizontally or vertically (see the diagram below.)
Horizontal plane Facing upwards
Within +/- 10
A
Viewed from point A in direction of arrow
There is no limitation on the joint mounting configuration. If the diameter of the refrigerant piping selected by the procedures described is different from the size of the joint, the connecting section should be cut with a pipe cutter. Branch pipe should be insulated with the insulator in each kit.
Service Manual 77
Installation
Test Running
SPLIT, ART cool, ART cool deluxe Type
1. Check that all tubing and wiring have been properly connected. 2. Check that the gas and liquid side service valves are fully open. 1) Prepare remote controller Remove the battery cover by pulling it according to the arrow direction. Insert new batteries making sure that the (+) and () of battery are installed correctly. Reattach the cover by pushing it back into position.
Bolt
Tubing connection
4) Evaluation of the performance Operate unit for 15~20 minutes, then check the system refrigerant charge: 1. Measure the pressure of the gas side service valve. 2. Measure the temperature of the intake and discharge of air. 3. Ensure the difference between the intake temperature and the discharge is more than 8C (Cooling) or reversely (Heating).
NOTE: Use 2 AAA(1.5volt) batteries. Do not use rechargeable batteries. Remove the batteries from the remote controller if the system is not going to be used for a long time. 2) Precautions in test run s The initial power supply must provide at least 90% of the rated voltage. Otherwise, the air conditioner should not be operated. s For test run, carry out the cooling operation firstly even during heating season. If heating operation is carried out firstly, it leads to the trouble of compressor. Then attention must be paid. s Carry out the test run more than 5 minutes without fail. (Test run will be cancelled 18 minutes later automatically) s The forced operation is started by pressing button for 2 seconds. (Cassette Type) The test run is started by pressing button for 5 seconds. (Cassette Type) The test run is started by pressing timer cancel button five times continuously. (Room type) s To cancel the test run, press any button. 3) Settlement of outdoor unit s Anchor the outdoor unit with a bolt and nut(10mm) tightly and horizontally on a concrete or rigid mount. s When installing on the wall, roof or rooftop, anchor the mounting base securely with a nail or wire assuming the influence of wind and earthquake. s In the case when the vibration of the unit is conveyed to the hose, secure the unit with an anti-vibration rubber.
Intake temperature
Discharge air
Discharge temperature
Intake temperature
Discharge air
Discharge temperature
CN_INSTALL
CEILING BOTTOM
Service Manual 79
System Layout
Distributor Unit For 2 rooms : PMBD3620 (9.52, 6.35) For 3 rooms : PMBD3630 (9.52, 6.35) For 4 rooms : PMBD3640 (9.52, 6.35) For 3 rooms : PMBD7230 (A: 12.7, 6.35) (B: 15.88, 6.35) (C: 15.88, 6.35) Do not connect more than 8 indoor units together choose the distributor unit type (2rooms,3rooms or 4rooms) according to the installation pattern
Branch Distributor A
Branch Pipe L1 L2
L3
L4
h2 Branch Distributor
L5 h1
L6
L7
L8
Main Pipe
B 40K(6rooms) 48K~56K(7~8rooms)
Service Manual 81
No.
Length
6 room
7 room
8 room
Total main piping length Total branch piping length Max. each branch piping length Total system piping length Maxium Level in - out Maxium Level in - in
A+B L1+L2+L3+L4+L5+L6+(L7)+(L8) L1, L2, L3, L4, L5, L6, L7,L8 (Total main) + (Tatal branch) h1 h2
50 50 15 100 30 10
50 60 15 110 30 10
50 60 15 120 30 10
Installation
This unit may be installed suspended from the ceiling or mounted on the wall. This unit may only be installed horizontally , as shown in the diagram below.(Side B is facing up) However, it may be freely installed in any direction forward or back, and to the sides. Be sure to leave a 600mm square opening for service and inspection as shown in the diagram below, for both ceiling - suspended installation and wall-mounted installation. This unit "does not require drain treatment" as it uses internal foam treatment as low-pressure piping insulation. Service direction is the side B and C The piping for the indoor unit may be led around in direction A The inclination of side B must be within 5C degrees forward or back or to the sides.
6.35 9.52
(298)
250
9.52
B
30 50
(38) 50
(56) 50 50 50
72 Branch Pipe
300
60 Cover Control
(111)
Min 400
Min 300
Inspection opening
(337)
Installation
This unit has two different installation types: (1) Ceiling-suspended type and (2) wall-mounted type. Choose the proper installation pattern according to the location of installation. The installation location for printed wiring board can be changed. Follow the procedure specified in the "CONNECTING THE WIRING" section to change the location.
(1) Ceiling-suspended type (2) Wall-mountde type
Procedure
(1) Fix the fumished hanger metal with two screws.(4 locations in total). (2) Using an insert-hole-in- anchor, hang the hanging bolt. (3) Install a hexagon nut and a flat washer (locally-procured)to the hanging bolt as shown in the figure in the left, and ift the main unit to hang on the hanger metal. (4) After checking with a level that the unit is level, tighten the hexagon nut. * The tilt of the unit should be within 5 in front/back and left/right.
BD unit Six-sided Nut (M10 or M8) Hanger metal Flat washer washer 15.00
Procedure
(1) Fix the fumished hanger metal with two screws. (3 locations in total). (2) After checking with a level that the unit is level, fix the unit with the furnished wood screws. * The tilt of the unit should be within 5 in front/back and left/right.
CAUTIONS Once a screw-hole on the main unit has had a screw hammered in, make sure to either hammer it again or cover it with alumium tape.(This is to prevent condensation) Be sure to install the unit with the ceiling-sie up. Do not install near bedrooms. the sound of refrigerant flowing through the piping may sometimes be audible.
Service Manual 83
Installation
Connection of Piping
When connecting indoor units, make sure to connect refrigerant pipes and connection wires to the appropriate connection ports maked with matching alphabets. (A, B, C, D)
NOTICE
Be sure to mark all the local refrigerant piping(liquid pipes, gas pipes, etc.) for each indoor unit designating clearly which room it belongs in.(A, B, C, D)
: For flaring work the piping, follow the instructions in the installation manual to each unit.
NOTICE
Connecting the pipings to the indoor unit and drain hose to drain pipe
1. Align the center of the pipings and sufficiently tighten the flare nut by hand. 2. Tighten the flare nut with a wrench.
Outside diameter mm inch 6.35 1/4 9.52 3/8 12.7 1/2 15.88 5/8 19.05 3/4 Torque kg.m 1.8 4.2 5.5 6.6 6.6
Open-end wrench (fixed) Flare nut Wrench BD Unit Socket Connection pipe
BD Unit Socket
Flare nut
Pipes
BD Unit
Wrap with vinyl tape Vinyl tape (wide) Connecting cable Pipe Vinyl tape(narrow)
Installation
Connection of Wiring
Connect refrigerant pipes and connection wires to the appropriate ports maked with matching alphabets (A, B and C) on this unit. Follow the instructions on the wiring nameplate to connect the connection wires of indoor/outdoor units to terminal board numbers.(1, 2 and 3) Always fix each ground wire separately with a ground screw.(See the figure below.) After completing the wiring, fix the outer coating of wires securely with wire clamps. The wire clamp on indoor unit side is furnished. Follow the procedure below to install. Refer to the circuit diagram on the control cover inside outdoor unit.
: The terminal board numbers are arranged from top to bottom in order of 1, 2 and 3.
NOTICE
In Case of 3 rooms
Warning Do not use tapped wires, stand wires, extensioncords, or starbust connections, as they may cause overtheating, electrical shock, or fire.
A B C CN-PWR
(1) Remove the control cover. Loosen the two screws, and slide the cover in the direction of the arrow.
(3) Put in the cover in the direction of the arrow then tighten the screws.
(2) Perform wiring with reference the wiring diagram on a control cover of outdoor unit. Allow 300 mm for the pulling-out section of harness. Fix the wires completely with wire clamps(4 locations).
Service Manual 85
Operation
Operation
Function of control
1. MAIN UNIT FUNCTION
DISPLAY
Operation Indicator On while in appliance operation, off while in appliance pause Flashing while in disconnection or short in Thermistor (3 sec off / 0.5 sec on) Sleep Timer Indicator On while in sleep timer mode, off when sleep timer cancel or appliance operation pause Timer Indicator On while in timer mode (on/off), off when timer mode is completed or canceled Defrost Indicator Off except when hot start during heating mode operation or while in defrost control
Operation
operates with the low or setting speed. When the indoor pipe temp is between 20C and 27C, it operates with Super-Low(while in sleep mode, with the medium airflow speed). While compressor off, the indoor fan is off when the indoor pipe temp is below 33C, when above 35C , it operates with the low airflow speed. While in defrost control, the indoor is outdoor fans are turned off.
s Defrost Control(Heating)
Defrost operation is controlled by timer and sensing temperature of outdoor pipe. The first defrost starts only when the outdoor pipe temperature falls below -6C after 35 minutes passed from starting of heating operation and more than 4 minutes operation of compressor. Defrost ends after 12 minutes passed from starting of defrost operation when the outdoor pipe temperature rises over 15C even before 12 minutes. The second defrost starts only when the outdoor pipe temperature falls below -6C after 35 minutes passed from ending of the first defrost and more than 4 minutes operation of compressor.
s Fuzzy Operation
When any of operation mode is not selected like the moment of the power on or when 3 hrs has passed since the operation off, the operation mode is selected. When determining the operation mode, the compressor, the outdoor fan, and the 4 way valve are off and only the indoor fan is operated for 15 seconds. Then an operation mode is selected according to the intake air temp at that moment as follows. 24C Inatake Air Temp Fuzzy Operation for Cooling 21C Inatake Air Temp<24C Fuzzy Operation for Dehumidification Inatake Air Temp<21C Fuzzy Operation for Heating If any of the operation modes among cooling / dehumidification / heating mode operations is carried out for 10 sec or longer before Fuzzy operation, the mode before Fuzzy operation is operated. 1) Fuzzy Operation for Cooling According to the setting temperature selected by Fuzzy rule, when the intake air temp is 0.5C or more below the setting temp, the compressor is turned off. When 0.5C or more above the setting temp, the compressor is turned on. Compressor ON Temp Setting Temp +0.5C Compressor OFF Temp Setting Temp + 0.5C At the beginning of Fuzzy mode operation, the setting temperature is automatically selected according to the intake air temp at that time. 26C Intake Air Temp 25C 24C Intake Air Temp<26C Intake Air Temp + 1C 22C Intake Air Temp<24C Intake Air Temp + 0.5C 18C Intake Air Temp<22C Intake Air Temp Intake Air Temp<18C 18C When the Fuzzy key (Temperature Control key) is input after the initial setting temperature is selected, the Fuzzy key value and the intake air temperature at that time are compared to select the setting temperature automatically according to the Fuzzy rule. While in Fuzzy operation, the airflow speed of the indoor fan is automatically selected according to the temperature.
Service Manual 87
Operation
2) Fuzzy Operation for Dehumidification According to the setting temperature selected by Fuzzy rule, when the intake air temp is 0.5C or more below the setting temp, the compressor is turned off. When 0.5C or more above the setting temp, the compressor is turned on. Compressor ON Temp Setting Temp + 0.5C Compressor OFF Temp Setting Temp+0.5C At the beginning of Fuzzy mode operation, the setting temperature is automatically selected according to the intake air temp at that time. 26C Intake Air Temp 25C 24C Intake Air Temp<26C Intake Air Temp+1C 22C Intake Air Temp<24C Intake Air Temp+0.5C 18C Intake Air Temp<22C Intake Air Temp Intake Air Temp<18C 18C When the Fuzzy key (Temperature Control key) is input after the initial setting temperature is selected, the Fuzzy key value and the intake air temperature at that time are compared to select the setting temperature automatically according to the Fuzzy rule. While in Fuzzy operation, the airflow speed of the indoor fan repeats the low airflow speed or pause as in dehumidification operation. 3) Fuzzy Operation for Heating According to the setting temperature selected by Fuzzy rule, when the intake air temp is 3C or more above the setting temp, the compressor is turned off. When below the setting temp, the compressor is turned on. Compressor ON Temp Setting Temp Compressor OFF Temp Setting Temp + 3C At the beginning of Fuzzy mode operation, the setting temperature is automatically selected according to the intake air temp at that time. 20CIntake Air Temp Intake Air Temp + 0.5C Intake Air Temp<20C 20C When the Fuzzy key (Temperature Control key) is input after the initial setting temperature is selected, the Fuzzy key value and the intake air temperature at that time are compared to select the setting temperature automatically according to the Fuzzy rule. While in Fuzzy operation, the airflow speed of the indoor fan is set to the high or the medium according to the intake air temperature and the setting temperature.
s On-Timer Operation
When the set time is reached after the time is input by the remote control, the appliance starts to operate. The timer LED is on when the on-timer is input. It is off when the time set by the timer is reached. If the appliance is operating at the time set by the timer, the operation continues. While in Fuzzy operation, the airflow speed of the indoor fan is automatically selected according to the temperature.
s Off-Timer Operation
When the set time is reached after the time is input by the remote control, the appliance stops operating. The timer LED is on when the off-timer is input. It is off when the time set by the timer is reached. If the appliance is on pause at the time set by the timer, the pause continues.
Service Manual 89
Operation
Soft Dry Operation Mode Intermittent operation of fan at low speed. Sleep Mode Auto Control The fan is switched to low(Cooling), med(Heating) speed. The unit will be stopped after 1, 2, 3, 4, 5, 6, 7 hours. Natural Air Control by CHAOS Logic The fan is switched to intermittent or irregular operation The fan speed is automatically switched from high to low speed. * Airflow Direction Control The louver can be set at the desired position or swing up and down automatically.(Model base) "Wall Mounted Type is standard" * Functions is dependent on model type. Deice (defrost) control (Heating) Both the indoor and outdoor fan stops during deicing. Hot start after deice ends. Hot-start Control (Heating) The indoor fan stops until the evaporator piping temperature will be reached at 27C.
Service Manual 91
Operation
Art Cool Deluxe Type Remote Controller
Operation ON/OFF
) )
: (High:39C
Temperature Setting
TEMPERATURE LOW HIGH
Low:11C)
Cooling
JET COOL
Heating
Timer Selection
ON
Timer Setting
SET
Timer Cancel
CANCEL
Sleep Operation
: 1, 2, 3, 4, 5, 6, 7, Off Timer
Airflow Direction Control 2nd F Air Circulation Reset
Service Manual 93
Operation
Operation Mode Selection Cooling Operation Mode ( Heating Operation Mode ( ) ) Soft Dry Operation Mode ( Auto Operation Mode ( ) )
LO (Low)
Room Temperature Display : High:39C LOW:11C Temperature Setting Cooling Setting the Timer
Timer Cancel
MED (Med)
HI (High)
Heating
Weekly Program
Program Week Holiday
Operation
Operation Mode Selection Cooling Operation Mode ( Heating Operation Mode ( ) ) Soft Dry Operation Mode ( Auto Operation Mode ( ) )
LO (Low)
Room Temperature Display : High:39C LOW:11C Temperature Setting Cooling
MED (Med)
HI (High)
JET
AUTO
Heating
Weekly Program
Program Week Holiday
Service Manual 95
Operation
) )
Fan Speed Selection (Low) Room, Temperature Checking (Med) (High) (CHAOS)
: (High:39C
Temperature Setting
TEMPERATURE LOW HIGH
Low:11C)
Cooling
JET COOL
Heating
PLASMA(Optional)
Timer Selection
ON OFF
ON
Timer Setting
SET
Timer Cancel
CANCEL
Sleep Operation
: 1, 2, 3, 4, 5, 6, 7, Off Timer
Airflow Direction Control
Air Circulation
2nd F Reset
Operation
Service Manual 97
Operation
Signal transmitter
START/STOP BUTTON Operation starts when this button is pressed and stops when the button is pressed again. OPERATION MODE SELECTION BUTTON Used to select the operation mode. ROOM TEMPERATURE SETTING BUTTONS Used to select the room temperature. INDOOR FAN SPEED SELECTOR Used to select fan speed in four steps low, medium, high and CHAOS. JET COOL Used to start or stop the speed cooling/heating. (Speed cooling/heating operates super high fan speed.) CHAOS SWING BUTTON Used to stop or start louver movement and set the desired up/down airflow direction. ON/OFF TIMER BUTTONS Used to set the time of starting and stopping operation. TIME SETTING BUTTONS Used to adjust the time. TIMER SET/CANCEL BUTTON Used to set the timer when the desired time is obtained and to cancel the Timer operation. Used to set Sleep Mode Auto operation. Used to circulate the room air without cooling or heating. Used to check the room temperature.
2 3
5 6
4
1 3
4 2 7 11 8 13
14 10
CANCEL ON OFF SET AUTO CLEAN
9 16
12 15
8
Flip-up door (opened)
Operation Mode
Cooling Operation Auto Operation
Cooling Model(
Used to start or stop the plasma-purification function. Initialize remote controller. Used prior to using modes printed in blue at the bottom of buttons.
16
Operation
SUB FUNCTION
Time Timer
Operation unit
03 05 07
AUTO Heater Preheat JET Defrost Humidify Filter Out door ZONE 1 2 3 4
17 19 21 23
Program set
09 11 13 15
3 Signal receiver 7 8 9 10 11 12 13
Timer Cancel
2 5
Holiday
Program
Week
6 4 14
RESET
15
1 2
Operation display Displays the operation conditions. On/Off Button Operation starts when this button is pressed, and stops when the button is pressed again. Set Temperature Button Used to set the temperature when the desired temperature is obtained. FAN Operation Button Used to circulate room air without cooling or heating. Fan Speed Button Used to set desired fan speed. Operation Mode Selection Button Used to select the operation mode. Auto Operation Mode. Cooling Operation Mode. Soft Dry Operation Mode. Heating Operation Mode.(except cooling model) Timer Cancel Button Used to cancel the timer.
Timer Set Button Used to set the timer when the desired time is obtained. Week Button Used to set a day of the week. Program Button Used to set the weekly timer. Holiday Button Used to set a holiday of the week. Time Set Button Used to set the time of the day and change the time in the weekly timer Function. Set and Clear Button Used to set and clear the weekly timer. Room Temperature Checking Button Used to check the room temperature. Reset Button Used to set the current time and clear the setting time.
9 10 11 12
5 6
13 14 15
Service Manual 99
Operation
SUB FUNCTION
Time Timer
Operation unit
03 05 07
AUTO Heater Preheat JET Defrost Humidify Filter Out door ZONE 1 2 3 4
17 19 21 23
Program set
09 11 13 15
3 4Way 17 10 11 12 13 14 15 16 18
Timer Cancel
2 5
Holiday Plasma Set/Clr Hour Min RESET
Cooling Model
Program
Week
4 7 8 9
1 Operation display
Used to set the timer when the desired time is obtained. Set Temperature Button 3 Used to set the temperature when the desired temper12 Week Button ature is obtained. Used to set a day of the week. 4 FAN Operation Button 13 Program Button Used to circulate room air without cooling or heating. Used to set the weekly timer. 5 Fan Speed (Jet Cool Button: 4 way) 14 Holiday Button Used to set the desired fan speed or select Jet cool Used to set a holiday of the week. mode. 15 Time Set Button 6 Operation Mode Selection Button Used to set the time of the day and change the time in Used to select the operation mode. the weekly timer Function. Auto Operation Mode 16 Set and Clear Button Cooling Operation Mode Used to set and clear the weekly timer. Soft Dry Operation Mode Heating Operation Mode(except cooling model) 17 Swirl Button (4 way) Used to select swirl mode. 7 Auto Swing Button Jet Cool Button (1 way) Used to swing up and down.
8 Room Temperature Checking Button 18 Reset Button
Operation starts when this button is pressed, and stops when the button is pressed again.
Used to set the current time and clear the setting time.
Display temperature can be different from actual room temperature if the remote controller is installed at the place where sun-rays are falling directly or the place nearby heat source.
Operation
1) Two Thermistor System (1) Open the rear cover of the wired remote-controller to set the mode. (2) Select one of three selectable modes as follows. Position 1: The room temperature is controlled by the thermistor of the main body. Position 2: The room themperature is controlled by the thermistor of the wired remote-controller, control the temperature according to the position of wired remote-controller. Position 3: The room temperature is controlled by lower temperature between the temperature of main body and of remote-controller sensor. (3) Move the slide switch to set position.
LO STAND HI
HIGH
CAUTION: Select the position after counselling with a customer. In case of cooling mode, room temperature is controlled by the main body sensor. To control the room temperature by a wired remote controller, install controller(room temp. sensor) to sense the temperature more accurately. Maunfactured in the position 1.
Operation
2) Group Control(Optional Wiring) You can use a group control operation after connecting the brown and yellow wire of each air-conditioner. Remove the resistor "OP 7" in remote controller. It operates maximum 16 Units by only one Wired Remote Controller, and each Unit starts sequentially to prevent overcurrent.
Wiring design
Indoor Unit 1
Terminal(Local Supply) Block Connector
RED(12V) YL(SIGNAL) BR(GND) RED(12V) YL(SIGNAL) BR(GND)
Main PCB
Indoor Unit 2
Terminal(Local Supply) Block Connector
YL(SIGNAL) BR(GND) YL(SIGNAL) BR(GND)
Indoor Unit 16
Terminal(Local Supply) Block Connector
Main PCB #1
Main PCB #2
....
YL(SIGNAL) BR(GND)
YL(SIGNAL) BR(GND)
....
AUTO SWING
OPERATION
SET TEMP
Room Temp
SUB FUNCTION
Time Timer
Operation unit
03 05 07
Slide Switch
Program set
09 11 13 15 17
Features
Use Only One Wired Remote Controller with several air conditioners(max. 16 Units) Random starting to prevent overcurrent.
CAUTION: Be careful not to exchange the color of wires. The maximum length of connecting wire should be below 200m(25) on connecting each units. Use a wire more than 0.5mm2
Operation
3) E.S.P.(External Static Pressure) Setting (1) Open the rear cover of the wired remote-controller to set the mode. (2) Select one of three selectable modes as follows. s Without Zone System 1. Position V-H, F-H: This position sets the maximum E.S.P as a default set. 2. Position V-L: This position sets the minimum E.S.P as a default set. s With Zone System 1. Position V-H: Maximum E.S.P setting & Fan speed is varied according to the state of dampers by micom. 2. Position F-H: Maximum E.S.P setting & Fan speed doesn't vary according to the opening & Closing of dampers. 3. Position V-L: Minimum E.S.P setting & Fan speed is varied according to the state of dampers by micom. * Maximum : 8mmAq Minimum : 0mmAq (3) Move the slide switch to set position.
TH
R13H
R12H
CO1H
OP5R16H
OP4
R14H OP3 SW TH
OP2
R15H
LO STAND HI
SW
HIGH
Operation
4) How to Set E.S.P? Procedure of RPM change: Ex) External Static pressure is 4mmAq for Model 36K. To protect the unit, compressor is designed to be off during E.S.P. setting.
SUB FUNCTION
Time
Operation unit
Set no. Time 01 03 05 07
Program set
09 11 13 15 17 19 21 23
Push the "Timer" and "Wind" button simultaneously for more then 3 seconds.
Timer
AUTO SWING OPERATION SET TEMP
Room Temp
SUB FUNCTION
Time
Operation unit
Set no. Time 01 03 05 07
Program set
09 11 13 15 17 19 21 23
Push the "Up" of "Down" button for E.S.P adjustment. And, adjust the number which you want.(In this example, the number is "225". Refer to the table 1 on the next page.)
AUTO SWING OPERATION SET TEMP
Room Temp
SUB FUNCTION
Time
Operation unit
Set no. Time 01 03 05 07
AUTO Heater Preheat JET Defrost Humidify Filter Out door ZONE 2
17 19 21 23
Program set
09 11 13 15
Note: The range of selection is from 1~254. Since, the display is two Digit only. If the range selection is above 100 then the third digit will appear in the screen as shown.
Shift the fan speed mode by pressing the fan speed button. And then, Adjust numbers of next steps by repeating the stage 3. (In this example, the numbers are "237" and "243" respectly)
Push the "Timer" and "Wind" button simultaneously for more than 3 seconds. Then, Wind Data is memorized by the EEPROM of the main PCB.
AUTO SWING OPERATION SET TEMP
Room Temp
SUB FUNCTION
Timer
Time
Operation unit
Set no. Time 01 03 05 07
Program set
09 11 13 15 17 19 21 23
Operation
Ca(Btu/h)
9K
Step(Hi/Med/Lo)
8 CMM 7 CMM 6 CMM 10 CMM
BT
12K
18K
13 CMM 12 CMM
Chassis
Static Pressure(mmAq)
Ca(Btu/h)
9K
Step(Hi/Med/Lo)
10.5 CMM 9 CMM 8.5 CMM 11.5 CMM
BP
12K
Chassis
Static Pressure(mmAq)
Ca(Btu/h) Step(Hi/Med/Lo)
16.5 CMM 18K 14.5 CMM 13 CMM 18 CMM 24K 16.5 CMM 14 CMM Chassis Static Pressure(mmAq)
BH
Ca(Btu/h) Step(Hi/Med/Lo)
26.5 CMM 30K 23 CMM 20 CMM 32 CMM 36K 29 CMM 26.5 CMM
BG
TOTAL On button
Operate all linked units sequentially.
Electrical wiring
s PICTORIAL VIEW OF THE CONNECTION
: PNF-P14A0M
PI485
MAIN PCB
CN_CENTRAL
Control Box
MAIN PCB
CN_CENTRAL N L
PI485
10 G A B VCC GND C D
CN OUT
INDOOR UNIT
SET The Address(Group No. & Indoor No.) * Refer to The Following sheet (1.3.5 Indoor unit Address setting method)
Vcc GND C D
CN-POWER GND CN-COM B CN-POWER S1 LED2 LED3 IC1P + + LED5 + S9 S5 + S6 LED4 S2 L CN-COM A S4
+
LED7
+
LED8 S11
S3
C GND VCC
TX1 S12
+
LED10
S10
+
LED11
LED9
LED12 S15
+
LED13
+
LED14
S14
+
LED15
+
LED16
S16
PWB:6870A10001A ASM:6711A20005E
+
LED17 ON KSDO4H L1 2 3 4 S19
S15
S18
All the connections are to be done as shown above. A and B are the communication lines for the indoor and C and D are the communication lines for the Central Control. Use two shield lines for C/D connecting line.(Earth the shield line)
Vcc
GND
C
CN-POWER GND
Master
DIP SWITCH
+
LED7
+
LED8 S11
S3
TX1 S12
+
LED10
S10
+
LED11
LED12 S15
+
LED13
+
LED14
S14
+
LED15
+
LED16
S16
C GND VCC
PWB:6870A10001A ASM:6711A20005E
+
LED17 ON KSDO4H L1 2 3 S19 4
S15
S18
Outdoor unit 1
INDOOR UNIT 1 INDOOR UNIT 2
Master Mode
Group Number 0
1. Adhere the PI485 Module(For connecting central control) to the Control Box. 2. Connect the PI485 Module to central control. 3. In the case of connecting two more than central control, set the Master/Slave mode and then connect each communication lines(C,D) <Refer to above fig>. *Special purcharse: Central control(P/No.:4995A20105F), PI485 Module(PNF-P14A0M) * It can be added to 15 Central controls for the slave control.
Note
<Group Number 1>
Vcc GND C
CN-POWER GND CN-COM B CN-POWER S1 LED2 LED3 S5 + S6 LED4 S2 L CN-COM A S4
001
Slave
DIP SWITCH
Group No. Indoor No.
TX1
+
LED7
+
LED8 S11
S3
+
LED10
S10
+
LED11
S12
LED12 S15
+
LED14
S14
+
LED15
+
LED16
S16
C GND VCC
LED13
PWB:6870A10001A ASM:6711A20005E
+
LED17 ON KSDO4H L1 2 3 S19 4
S15
S18
Outdoor unit 2
Master Mode
Group Number 0
ON KS DO 4H L1 2 3 4
1 ON + All OFF : Connection of "TPS Inverter Multi Connection + General Central Controller" Case.
ON KS DO 4H
Central Controller applied LGAP " Case. * LGAP : LG Air conditioners Protocol
Function of LG Network - It is possible to connect the network of LG air conditioners and to connect various contents of the network system, which is simple, deluxe and PC central control. - Please refer to "LG Control System Manual" about the detail functions and the products possible to network. - As the Interface for networking, PNF-P14A0M/R/C is applied.
1. Press 13(program) and 16(set and clear) key more than 3 second then "Address Setting Mode" starts. 2. Set the address of indoor unit by using "Temperature setting" key. s Range of address : 00 ~ FF
1
AUTO SWING
OPERATION
SET TEMP
Room Temp
SUB FUNCTION
Time Timer
Operation unit
03 05 07
AUTO Heater Preheat JET Defrost Humidify Filter Out door ZONE 1 2 3 4
17 19 21 23
Program set
09 11 13 15
2 5
Holiday Plasma Set/Clr Hour Min RESET
Ex)
Program
Week
6 4 7 8 9
1) Press 5(Jet Cool) & 13(Reset) key at the same time more than 3 seconds then "Address Setting Mode" starts. 2) Set the address of indoor unit by using "Temperature setting" key. s Range of address : 00 ~ FF
5 6
1 3
Ex)
4 2 7 11 8 13 14 10
CANCEL ON OFF SET AUTO CLEAN
9 16 12 15
2.
2. Address Monitoring
1) Press 6(Chaos Swing) & 13(Reset) key at the same time then "Address Monitoring Mode" starts. 2) At the address monitoring mode, pressing 1(On/Off) key, The address that is set is displayed on a display window of indoor unit. * notice : The mothod of display and time is different according to indoor unit type. 3) If the remote control is reset, normal mode starts.
* Notice : Confirm that wired and wireless remote control are able to select the address or not.
Installation
s CAUTIONS
Keep in mind
Dont operate with wet hands.
Control Devices and Function s INSTALLATION ORDER 1. Remove upper & lower case. 2. Fixate screw in the holes of the
case bottom.
5. Adjust the upper case in accordance with back case while assembling as shown in the figure.
s LINK OF CONNECTING WIRE 1. First, separate the front case from rear case of controller, connect terminal
C, D,Vcc, GND on PCB referring to the following table. Maximum length of connecting wire Between controller and outdoor unit : 220m(25 Between controllers : 220m(25 ) )
Vcc
GND D C
2. After attaching the supplied wire to terminal, link the connecting wire.
If necessary, Cut the indicated part of front case to draw the lead wire.
Control Devices and Function s. ROTARY SWITCH SETTING(INSTALLATION FOR 2 OR MORE SIMPLE CENTRAL CONTROL)
The setting of Group Number in the Central Control is done by the rotary switch as shown in the figure below.
It is possible to set 0~15 Group(Total 16 Groups). All the numbers on the rotary switch represent the different Group Numbers. By changing the knob we can set rotary switch to the group number we want to control. The above fig. Shows the control of group number 0. Similarly we can control all the 16 Groups.
Slave Mode
s. ACCEASSORY PARTS
Central control and sub (with wire ass'y) should be purchased as optional.
Central Control(1EA)
PI485(PQNFP14A0M)
Wire Assembly 1
Screw(4EA)
Wire Assembly 2
Outdoor Unit
CNU
PI485
Outdoor Unit
PI485
Major Characteristics
1. Individual/Integrated Operation/Monitoring
s You can identify operation status of the air conditioner, operation mode, wind quantity, wind direction, locking, temperature setting and error, etc by selecting the installed air conditioner through individual selection, group selection or all selection. Individual setup and operation of the detailed functions are available. Therefore, managing with Deluxe Central control installed at the control room at a building where a number of air conditioners are installed, is a convenient way.
2. Group Management
s Group management for the installed air conditioners is available. Group can be seperated by their nature, location and size of each air conditioner which enables convenient use. In addition, allotment of respective name to the setup group allows further intuitive management.
3. Self-diagnosis Function
s The air conditioner installed can self-diagnosed its error status and then transmits the result to the central control. Therefore, a rapid countermeasure against failure of the air conditioner allows easy management and increases the usage life of air conditioner.
9. Mobility
s A wireless radio system may be installed at the Deluxe Central control, it will control the Airconditioners directly while going around the building with the wireless radio system and its self-battery function (100 m where there is no obstacle).
12. Scalability
s Scalability of the system is easy in case of additionally purchasing equipment since scalable slot such as USB, Serial (RS-232c), PCMCIA, CF Type is prepared. This system is designed considering sufficient scalability in provision for special request by the customer.
13. Upgrade
s Additional installation of a new program is available via the CF memory card and the existing program can be upgraded to a new program. Using such upgrade function always enables to construct a modern type of Central Control System.
1) For the PC central control, installation set numbers may respond up to 1024 sets upon users request. 2) JVM (Java Virtual Machine) is basically installed at the Windows but some versions of Window XP may be manually installed.
PQCSW501A0, PQCSW502A0
[ System Monitor ]
To check the ctual time status of all air conditioners.
PQCSW501A0, PQCSW502A0
[ System Set-up ]
To manage the air conditioner through grouping and record setup of group and installation position, etc.
PQCSW501A0, PQCSW502A0
[ Time Schedule ]
Setup of a weekly schedule for all, group and individual air conditioner enabled operation of the system. Processing through enlist of extra schedule for a year is available.
PQCSW502A0
System Configuration
Scenario 1 : In case of not using Internet access function
B part
A part
Product
CNU PI485
PI485
Cross UTP Cable (Cross LAN Cable) RS-485 Cable
PI485
PI485
* CNU: Central control Network interface Unit PI485: Product Interface unit for IEEE485 transmission.
Main Specifications
1. Control System
- Centralized control of maximum 256 indoor units - Simple Touch PAD method - GUI setting considering convenience of use - Power failure compensation with independent Battery Built-in (Max. 2 hours)
2. CNU
- Combination of maximum 8 outdoor units - 485 to Ethernet Converter Built-in
3. PI485
- 1 pcs per outdoor units Note: - GUI(Graphic User Interface) may be changed without any notice, for improvement or options.
To remove the Grille from the Chassis. Set the up-and-down air discharge louver to open position (horizontally) by finger pressure. Remove the securing screws To remove the Grille, pull the lower left and right side of the grille toward you (slightly tilted) and lift it straight upward.
Screw
1) To remove the sensor, housing connect, earth conductor & step motor conductor with sensor holder, Motor, Evaporator & P.C.B.
Earth Conductor
3) To remove the Discharge Grille. Pull the discharge grille out from the chassis carefully.
4) To remove the Evaporator. Remove screws securing the evaporator and the holder eva.
Unhook the tab on the right inside of the chassis at the same time, slightly pull the evaporator toward you until the tab is clear of the slot.
5) To remove the Cross-Flow Fan Loosen the screw securing the cross-flow fan to the fan motor (do not remove). Lift up the right side of the cross-flow fan and the fan motor, separate the fan motor from the cross-flow fan.
Remove the left end of the cross-flow fan from the self-aligning bearing.
Disassembly of the parts 2. Art Cool Type Indoor Unit CAUTION: Disconnect the unit from power supply before making any checks. Be sure the power switch is set to OFF.
1. To remove the Grille from the Chassis. - Pull the grille bottom, the remove 2 securing screws. - Lift the both lower parts of panel front. - After pull down this panel a bit, separate connecting wire with product.
2. To remove the Control Box. - Before removing the control box, be sure to disconnect the wires from PWB. - Pull the cover control out from the control box and disconnect other wires. - Remove securing screws. - Pull the control box out from the chassis carefully.
4Way/Fan Connector Comp Connector Power Connector Power Connector Comp Connector Motor Connector
4) Before removing the Turbo Fan. - Remove the securing screws from the chassis. - Pull the pipe cover, top cover and the air guide.
Top Cover
Air Guide
Pipe Cover
5) To remove the Motor. - Remove the securing bolt from the motor shaft. - Pull the fan out from the motor shaft. - Remove 4 screws securing motor mount from the chassis and lift up the motor mount and the bracket.
Bracket
Turbo Fan
Bolt
Motor Mount
Disassembly of the parts 3. Art Cool Deluxe Type Indoor Unit CAUTION: Disconnect the unit from power supply before making any checks. Be sure the power switch is set to OFF.
To remove the Grille from the Chassis. Hold up Inlet Grille Horizentally. To remove the Grille, pull the lower left and right side of the grille toward you (slightly tilted) and lift it straight upward. To seperate connecter assembly and than to remove Inlet Grille assembly.
1) Before removing the control box, be sure to take out the wire screwed at the other end.
3) To remove the Discharge Grille. Unhook the discharge grille and pull the discharge grille out from the chassis carefully.
4) To remove the Evaporator. Remove 3 screws securing the evaporator(at the left 2EA in the Eva Holder, at the right 1EA).
5) To remove the Motor Cover Remove 2 securing screw. Pull the motor cover out from the chassis carefully.
Motor cover 6) To remove the Cross-Flow Fan Loosen the screw securing the cross-flow fan to the fan motor (do not remove). Lift up the right side of the cross-flow fan and the fan motor, separate the fan motor from the cross-flow fan.
Remove the left end of the cross-flow fan from the self-aligning bearing.
1. Remove the air filter. Pull the inlet grille slightly toward you. Pull out the air filter. (2 pieces)
Inlet Grille
2. Remove the girlle from chassis Remove the screws securing the side plate and push to the bottom-side. Unhook the hanger from the hanger screw at the left and the right side. Pick out the inlet grille.
3. Remove the lower air guide Remove a screw of both side fixing "barrier airguide". Remove the screws of both sides of the lower air-guide. Remove the lower air-guide toward arrow mark by turning upwards as shown in figure.
Barrier Air guide Lower Air guide
VE chassis
Warning : Disconnect the unit from power supply before making any checks. Be sure the power switch is set to OFF.
To remove the Grille from the Chassis. Set the up-and-down air discharge louver to open position (horizontally) by finger pressure. Remove the securing screws. To remove the Grille, pull the lower left and right side of the grille toward you (slightly tilted) and lift it straight upward.
1. Before removing the control box, be sure to take out the wire screwed at the other end.
3. To remove the Discharge Grille. Unhook the discharge grille and pull the discharge grille out from the chassis carefully.
4. To remove the Evaporator. Remove 3 screws securing the evaporator(at the left 2EA in the Eva Holder, at the right 1EA).
5. To remove the Motor Cover Remove 2 securing screw. Pull the motor cover out from the chassis carefully.
6. To remove the Cross-Flow Fan Loosen the screw securing the cross-flow fan to the fan motor (do not remove). Lift up the right side of the cross-flow fan and the fan motor, separate the fan motor from the cross-flow fan.
Remove the left end of the cross-flow fan from the self-aligning bearing.
Door Switch
R
Remove a bearing assembly by removing a screw and the bearing cover. Remove 4 screws securing the motor cover. Loosen the screw securing the crossflow fan to the fan motor shaft. (do not remove) Remove the crossflow fan by sliding it out from the shaft of fan motor.
Motor Cover
Bearing Cover
R
Bearing
5. Remove the control box Assembly. Disconnect the step motor connector, fan motor connector, display PCB connector, thermistor connector and door switch connector from the main PCB. If necessary, disconnect power supply cord and connecting cable from the terminal block and remove the cord clamp screw. Remove 2 screws securing the control box and pick out the control box carefully.
7. Remove the diffuser assembly. Remove the screws of both side of diffuser assembly. (4 pieces) Push the upper side of cabinet strongly to pull out the inner hook of diffuser frame from the cabinet hole. Take up the diffuser frame carefully not so as to harm the display PCB wires and the step motor wires.
8. Remove display PCB assembly. Remove the screws at the both side of display cover. If necessary, disconnect the display PCB connector from PCB assembly. Remove 2 screws of PCB assembly.
Display Cover
Lower Vane
Upper Vane
10. Remove the drain pan assembly. Remove the both side of screws. (4 pieces) Pull out the drain pan assembly. Be careful not to harm to the EPS packing of drain pan and the tubings of evaporator.
11. Remove the evaporator. Remove the screws of both sides securing the EVA barrier-R/L on the side cabinet. Remove the screws which fasten the barrier on the evaporator and take out the barrier assembly. Remove the evaporator assembly by sliding toward arrow mark. (As shown in figure)
EVA. Barrier-L
Side Cabinet
EVA. Barrier-R
Schematic Diagram
5V
R04F,10K
R02F,10K
1
R03F,1K R01F,1K
4 MICOM GMS81516
5V
R02H 12.1K 1% 1% 6.2K 12.1K 12.1K 12.1K 12.1K 12.1K 12.1K R04H R16H R15H R14H R12H R11H R13H R16G,6.8K R15G,6.8K Q13G KTA1270Y
DISPLAY
DC 5V
GND
REMOCON
Vout
1
C01M
3
R13G,6.8K Q12G
LED4
Vcc
2 3 4 5 6 7
LED3
0.01 50V
5
R12G,6.8K R11G,,6.8K Q11G KRA1270Y
LED2
C02L
LED1
CN-DISP1
220uF IC02M
CN-TH
PIPE-TH
10V
8 9 10
R03H,1K
KID65004AP
CN-DISP2
R06G,220
1 2 3
R01H,1K
1 2 3 4
C01H C02H
1 2
16 15
R01G,220
2
4 13
R07G,220
3 R03 53 D4 D5 D6 R54/WDTO R53/Srdy R52/Sclk R51/Sout R50/Sin R47/T30 R46/T10 R45/EC2 R44/EC0
TX RX
5 12
R02G,220
4
ROOM-TH
R04G,220
R05G,220
0.01 50V
CN-U/D
6 EEPROM R07 49 R10 48 R11 47 R12 46 R13 45 R14 44 R15 43 R16 42 R17 41 R43/INT3 R42/INT2 R41/INT1 A8 R20 40 A10 R21 39 A11 R22 38
DC 12V
8 9
R03G,220
7 S 1 C 2 D 3 Q 4 8 VCC 7 DU
R01T,10K R02T,10K R03T,10K
RD
1 1
DC 12V
OR
2 3 4 5 15 4 3 2 1 16 17 18 5 14 5 4 13 6 3 12 7 2 11 8
DC12V
10
OP6 XXXK OP5 XXXK OP4 XXXK OP3 XXXK OP2 XXXK
OP1 XXXK
DC 5V
DC 5V
YL PK BL
STEP MOTOR UP/DOWN
DC 12V
1 6 ORG 5 Vss
R04T,10K
R05T,10K
DC 5V
IC01M
Schematic Diagram
KID65084AP
9
SSR-MOTOR
CN-SUB
R02E,20
R02A,4.7K R01A,1K
28 R40/INT0
5V
A12 R23 37
29
R03A,100 KIA7036P C01A 0.01 50V
RESET'
30
BZ01E R01E,1K
IC01A C02A 10uF/50V
+
Q01M KRC107M
A14 R25 35
31 32
R02L,10K
OSC01B CST-8.00MTW
XOUT VSS
5V
IC01K(TLP621)
R01L,1K
REMOCON
D01K 1SR139-600
RX
5V
1 IC02K(TLP627) 2 3
R03K 1K
ZNR01K 14D271
NF01M
ZNR01M INR14D471K
CN-FAN
NF01M
R02C,4.7K
R01C,1K
SSR-MOTOR
INDOOR
5V
R04C,10K
FREQUENCY
R03C,20K R05C 4.7K M C02C 0.015 50V Q01C KTC3198Y C01C 0.01 25V
DC 5V
C06D 0.01 25V +
Q01K KRC102M
R04K 680
R05K 25K,3W,1%
R01M,120,1/2W
C01M,0.1,AC275V
FAN MOTOR
IC02D
O 7805 C05D 470uF 16V I D02K 1SR139-600
COM
NF01J
FUSE 250V/T2A
FREQUENCY
LIVE
1. Indoor Unit
1) Split Type
IC01D
DC 12V
C04D 0.01 25V + O C03D 470uF 25V 7812 I + C02D 0.1 50V
D01D 1SR139-600
D02D-05D 1SR139-600
NEUTRAL
CN-POWER
POWER TRANS
6171AQ3124C
DC310V
C05D 681
CN-POWER
2
5V C10D 103 C11D 223/1KV C12D 103/1KV NF NTC01D 10D-9 ZD01D P6KE200A C06D 3 4,5 IC02D(TLP521) EN BP R03D 150 ZD02D 11V C04D 103/250VA C07D 330uF/35V
470uF/35V
2
D03D UF5402 3.3uH G C08D 104
R04D
LIVE
1 2
250V/ T3.15A,3A
ZNR01J INR14D561K
NF01J 22mH/3A
R01J D01D 1M,1/2W 1N4007
12V
L01D
1 6,7
S/Trans
C09D 220uF/50V
IC11K(TLP621)
R11K 10K
C11K 102
M_RTX
R13K 1.5K
RX
2 1 3 4
Multi_RX
R12K,1K
DC 5V
M_RTX
D12K 1SR139-400 D11K 1SR139-400
DC 5V
1
AC_N C01D 10uF/ 400V IC01D TNY255P S 3,7,8
CN-OUT RY-OUTFAN 1 RY-4WAY 3 3 RY-4WAY 1 RY-OUTFAN
NEUTRAL
3 4
39
R16K 10K 3 4
R15K 82K/3W
3 3
M_RTX
RY-COMP
SIGNAL
C03J 10nF 275V C01J 100nF 275V D02D UF4005 D 5 4 TNY 255P 2 1 C03D 103 C02J 100nF 275V
2 1 IC12K(TLP627) R14K 1K
TX Multi_TX
DC 5V
Q11K
KRC104M
AC_L
12V
DC 12V
CN-REMO
STEP M5
RY-HEATER 5 5
1
P76 P77 P00 P73 P72 P71 P70 VDD (AIN7)/P67 (AIN6)/P66 (AIN5)/P65 (AIN4)/P64 (AIN3)/P63 (AIN2)/P62 (AIN1)/P61 P14(PPG) (AIN0)/P60 P01 P02 P03 P04 P05 P06 P07 P10(INT0) P11(INT1) P12(INT2/TC1) P13(DVO) P74
P75
64 63 62 61 60 59 58 57 56 55 54 53 52 51 50
5V
HEATER
_TX
Q03K KRC104M
R02K
L03K
MED
2 3 4 5 6 7 8 9 10 11 12 13 14 15
Q D
2 3
4WAY
Q01K
4.7K
2 1
CN-D/PUMP
Drain Motor
L02K
KRA104M
STEP M
RY-D/PUMP
CN-LOUVER
Louver Motor
STEP M
R07H 12.1K 1%
R05H 12.1K 1%
R03H 12.1K 1%
5V
12V
5V
R01K
1 3 RY-LOUV 3
STEP M4
STEP M
R08H 12.1K 1%
R06H 12.1K 1%
R04H 12.1K 1%
1K
_RX
C03K 102
D02K
1 2
LOW
IC01M KID65004AF
C01K 102
C02K 102
Q04K
DAN212K
KRA104M
FAN
DC 12V
3 4
REMO 50/60Hz
CN-PIPE
3 3
Q02K KRC104M
MOTOR
REMO
C02L 681
OPTION2 PIPE TH
FREQ
5V
5V
R03C 10K
AC_L
1
R06C 10K
1 FAN 2
ZNR01M
1 2 3
IC01C
BZ01E
R02E 20
R04C 4.7K
ROOM TH OPTION 1
50/60Hz
MOTOR 3
PHASE
EERROM 1 S
CN-ROOM CN_M C
AC_N
Q01C
R05C 1K
C01C 103
R02A 10K
5V
1
R01E 1K
5V
VCC 7 DU C 8
16 17
C
P15(TC2) P16
VARF VASS
49 48 18
P17 P54 SB3
5V
12V
KIA7036P
+ 2
R01A 1K
GND
1
OR1 C02H C01H 103 103
5V
1 2 2
12V 5V
C02A 102
6 ORG
47
Q 4
S_B3
S
GND
19 20
NC
P20(INT5/STOP) TEST
P53 (PWM/PDO)/P52
46 45 21
P21(XTIN) (INT4/TC4)/P51
SB2 SB1
S_B2
5V
R01U 10K
S_B1
GND
3
C02U 103
3 4
SB0
Multi_TX
GND
4 5 5
PLC_SEL Multi_TX
DISPLAY
GND
1 2
LED1
1 2 3 4 5 6 7
5V
44
REMO
S_B0
Vout
NC RESET XIN
R01B
Vcc
3
R04L 1K
23 24
1.0M
(SO2)/P47 (SI2)/P46
42 41 25 26
LED1 XOUT VSS (SCK2)/P45 (SO1)/P44
CC TX
_TX _RX
GND 5V
1 2
1 2
GND 5V
LED2
4
R05L 1K
5 6 7
40 39 27
CN-DISP
_TX
12V
3
SO1/PLC P30 LED2 (SI1)/P43
3 4 4
12V SO1
Force SW
LED4
R06L 1K
38 28
5V
SI1
37 29
P32 NC
SCK1
36
R02F R01F
7
LED4
1K 1K
CS0
CN-LOUVER 1 3 3 1
30
LOUVER FLOAT
P33
NC
35 31 32
P34 P35
C02F 103 C01F 103
8
NC NC
CS1
Schematic Diagram
34 33
CSO
CN_ZONE
CN-FLOAT 1 2 1 2
CSI
R03L 1K
22
P22(XTOUT)
(INT3/TC3)/P50
43
CC RX
Multi_RX
6
_RX
Multi_RX
+5V
5V
D06N 1N4148 D01N~D04N 1SR139-600
~ +
CT01N
CN_TH1
1
R11H R14H R15H R12H R13H
Discharge Suction
2 3 4 4
R01H~R05H 1K
~
CT_AD
R02N,1.65K,1% C01N 100UF
+
2 3
1UF/50V C11H~C15H
6.2K
12.1K
OUT_Air
CN_TH2
1 2 3 4 4 3 2 1
5V 5V
R16H R17H R18H R19H
OUT_Pipe
DISCHARGE
CN_TH3
2 1 1 2
IC01M GMS81516
1 P70(AIN10) 2 3 4 5 6
R20H
C17D 103
6.2K
12.1K
6.2K
6.2K
6.2K
VDD P71(AIN11) P72(AIN12) P73(AIN13) P74(AIN14) P75(AIN15) P67(AIN07) P66(AIN06) P65(AIN05) P64(AIN04) P63(AIN03)
64 63 62 61 60 59
Pipe F
OUT_AIR
+ + + + +
OUT_PIPE TSUP_F
C01H 104 C03H 104 C04H 104 C05H 104 C02H 104
CT_AD DC_LINK
D01M
EG01C
R10T~R15T, 270
7 P76(AIN16)
P62(AIN02)
H/Press INT
8 P77(AIN17)
58
Q01M KRC107M
P61(AIN01)
W2 V2 U2 W1
9 P00(W) 10 P01(V) 11 P02(U) 12 P03(W)
57
56 55 54 53 52 51
311V
+5V
R03T,1K
7 R02T 7
C31K 15uF,450V
18 U1 1
10K
Q01T
RY-PWR F0_IPM
107M
C04T 103 R04T
R01T 10k
15 P06(EMG1) 16 P07(CL1/PDW1)
P51(INT4/TC4) P50(INT3/TC3)
50 49
TX_C
IPM_5V_ENB
17 P10(INT0)
P47(SDA/SO)
R31K 1M,1/2W
48
RX_B
12V
BUS_COM
CN-IPM
U
+
U_
V_
W_
Fo
5V
1K
LED01T (RED)
+5V
RY-HEATER
TEST S/W R05T
17 U1 16 2
18 P11(INT1)
P46(SCL/SI)
47
TX_B
RY-4WAY
U1 3
C13K 471,250V
19 P12(INT2/TC1)
P45(SCK)
RY-SV
1K
15 U1 4
46 20 P13
RX_A P44(TxD)
RY-FAN_1H
45
1 1
1 2 3
IC10S
4 3
2 8 8
1 2 3 4
R08T
3 9 9
10K 47uF/50V
4 6 6 7 7 4 5
TX_A
R07T
5V
BUS_ADDR_LEV
1K
R06T
14
IC01S
3 2
4
IC06S IC05S IC07S IC09S IC02S IC08S IC03S IC04S
56K
13
U1
RY-FAN_1L
LED02T (YELLOW)
U1 6
22 P15(DVO/TC2)
P42
RY-FAN_2H
23 P16(PDV1)
43
LEV_CTL_B P41
42
RC01M
21 P14(PPG)
P43(RxD)
44
LEV_CTL_C LEV_CTL_A
RY-SV
TLP559*6 TLP521*4
1 5 6 8 2
+5V
R01A,1K
12
CN_Test 2
+5V
C01A 102
11 10
U1
RY-FAN_2L
U1 8 9
24 P17(PDU1)
P40
RY-START
+5V
R30M
41 25 P20(INT5/STOP)
IC04M KIA65084 4.7K
D09D 1SR139-400
LEV_ENABLE P37
26 TEST 40
LEV_B_1
Q01Z KRA107M
R12M~R22M 4.7K
CN-SV
C07S 104 R01S 20K C08S 104 R02S 20K R03S 20K C09S 104 C10S R04S 104 20K C11S R05S 104 20K
C03A 10uF/50V
P36
+5V +12V
IC04D
39 27 P21
C04M 104
LEV_B_2
RY-4WAY
RC02M
S-TRANS CN-GATE2
D10D
17
+
P35
7805
38 28 P22
R08D 1.2K
+ + +
LEV_B_3
D08D RU2YX
P34
29 RESET 30 XIN
37
LEV_B_4
CN-4WAY
6 5 4 3 2 1
6 5 4 3 2 1
15 V
P33 P32
16
36 35
C03D 2200UF 35V
C04D 680UF C15D C16D 103 104 C05D 220UF 16V
LEV_A_1 LEV_A_2
RY-HEATER
C06S 10UF
15 8
C14D 473
R09D 1K
OSC01B 16MHz
31 XOUT
R01B,1M
P31
32 VSS
DC LINK
IC03D,SE012N
14 1
34
LEV_A_3
P30
LED01Y(GREEN)
R03D 47K 3W
33
R05Y 15K R03Y 82K 1/4W R02Y 70K,3W
LEV_A_4
RY-FAN2_L
CN-HEATER
CN_TH5
TX_F
CN_TH4
CN_TH3
SUCTION
R06H~R10H 1K
C16H~C20H
1UF/50V
1 2 2 3 4 5 6 8 9 3 4 5 6 8 9
G/Y
MOTOR
7 6 5 4 3 2 1
15 V
7 6 5 4 3 2 1
13
+
D05D EG01C
R07Y,1K
C08D 220UF 35V
12 2
Q01Y C3198
ZD01Y 20V 1W
R01Y 70K,3W
RC03M
D12D
C11D,473,630V
+5V 1/4W
+5V
Q02Y C3198
H/Press INT
RY-FAN2_H
IC01V TLP621-BL
FB01D FBA04HA900
IC02D TLP621-BL
FAN2
RY-DISC
R06Y,10K IC01Y TLP621 R04Y 2.2K 1/4W C01Y 222
+12V
D01V 1SR139-600
R03V 33K
R06V 1K
R04M~R20M 68K
RY-FAN1_L
C01V 102
1/4W
D13D
11
CN-FAN2
G/Y
C01S 10UF
+ + +
C02S 10UF
C03S 10UF
IC01D
FB02D R05D 5.6K 1/4W
R05V 10K
D01D~D04D 1SR139-600 R01D 27,5W NF01J
MOTOR
RC05M
9 8
9 8
Vupc Up Vup1 Vvpc Vp Vvp1 Vwpc Wp Vwp1 1 2 3 4 5 6 7 8 9 10 11 12 Vfo Ufo Wfo Un 16 Vn1 14 Vn 17
Br Wn F0 Vnc 13 18 15 19
RY-FAN1_H
C09D 330UF 35V
10
2
5 R06D 680,1/4W 3 C13D 680P D07D 1N4937 50V
G6551
ZNR01D ZNR561D14
RC04M
R07D 1 ,1W
+
CN-FAN1
CN-GATE1
4
GND In Vcc Fo GND Vcc In GND TEMP Out Si Out Si GND Out Si GND GND Out Si GND Out Si GND In GND Vcc Vcc
GND In Vcc Fo In Fo
Fo
Fo
Vcc
In
Fo
GND
Vcc
In
Fo
GND
RY-START
Out Si GND Out Si GND
R02D 82K,1W
R00D 1M,1/2W
C02J 104,275V
C01J 104,275V
1 1 -
2 2
PTC
1
CN-AC
CN-POWER
IPM
PM50CSD120
+
W N B
NC
4
HIGH PRESS Comp OLP
REACTOR 28A 0.68mH
RM20TPM-2H AC440V/DC1600V, 40A
1 1
1 1
2 2
RED
DSA-362MA
561
WHITE
Schematic Diagram
L2:1.5mH
L1:2.0mH
Power Relay
1uF
BLACK
472 332
1W/1M 2.0uF
GND
1uF
N
COMP
400V 2200uF
800V,0.27uF
100K,2W
CT01N/30A 1:3000
472 332
1W/1M 2.0uF
821 (102)
500V,25A
1uF
1uF
400V 2200uF
100K,2W
472 332
1uF
1uF
1W/1M 2.0uF
821 (102)
500V,25A 561
821 (102)
472 332
500V,25A
3 ,380V,60Hz CN-INPUT
FUSE 250V/5A
FAN1
+
2. Outdoor Unit
Schematic Diagram
DISCHARGE2 CN-TH4
1 1 2 2
+5V
3
R16H DISCHARGE1 CN-TH3 R08H R07H R06H R05H R04H R03H PIPE CN-TH2 4.7K 2012 6.2K,1% 2012 12.1K,1% 2012 6.2K,1% 2012 18K,1% 2012 18K,1% 2012 12.1K,1% 2012 1.5K,1% 2012 R15H R12H R11H R14H R13H R10H R09H
1 2 3 4 4 2 3
CN_LEV1
+15V
+5V
SUCTION
C03M 104
1
1 2 3
SW1 OR1 LONG C06H 10uF 50V 50V
LOW-V
1 2 3 4
+
C05H 10uF 50V 50V 50V 50V JIG POINT R14T 1K 2012 10uF 10uF 10uF 10uF R03N 20K 2012 C02N 102K 2012 C04H C02H C01H C03H C.T NORMAL R01H R01H~R08H 1K 2012 C07H~C12H C102*7 R04T 4.7K
INPUT VOLT
R02H
20
VCC A0 A1 A2
IC07M KIA65084
2 3
LEV1
19
CS
CS-1
OUT AIR
4
+ + + + +
1 2 3
18
B0
18
6
4
HEAT SINK
1
PIPE LENGTH
1 2
R01P~R04P 470K 1/2W 1% R05P~R10P
2012
17
B1 A3
17
CN_LEV2
ER_CODE, INDICATOR
5
16
B2 A4
6
16
1
LED01G : RED_10 LED02G : GREEN_1
2
C05P 102 +5V C09D 104 L03D 12uH R01L 4.7K R02L 4.7K +5V +5V 20K
2012
CN-TH1 5V : NORMAL GND : LONG C01L 103 2012 R15P~R17P 4.7K 1/4W(or 2012) G
+15V +5V
15
B3 A5
TX_JIG_S RX_JIG_S
7
15
14
B4
14
W V U
R05P
9 8 14
3 1 8
100 99 98 97 96 95 94 93 92 89 88 90 91
2012 2012
IC01M KID65004AP
LED0 1 18 R01G 1.5K
A6 +15V LED01G A7
8 9
13
B5
13
4
85 84 83 82 81
LEV2
Vcc
12
B6
12
5
87 86
GND
10
P03/AN03 P05/AN05 P07/AN07 P02/AN02 P04/AN04 P06/AN06
5
R02G 17 1.5K LED02G
5 4 2
R19P
P96 P95 P94 P93 P92 P91 P90 BYTE CNVss P87 P86 RESET Xout Vss Xin Vcc1
2
AVcc P10/AN0 P101/AN1 P103/HEAT_SINK P105/PIPE P107/DISCHARGE1 P97 Vref AVss P102/AN2 P104/OUT_AIR P106/SUCTION
7 6
1 2
SCL SDA
WP
P01/AN01 P00/DISCHARGE2
11
B7
11
6
80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51
LED0 LED1 PCB Auto Check
6
LED1 2 3 4
IPM Fault Signal
P14 INT3 INT4 INT5 P20/AN20 P21/AN21 P22/AN22 P23/AN23
A1
N
C07Z,09Z,11Z : 104K 2012
R09P
3 4
3
EEPROM M24C08
9 16 15 5
INT_HP PSC F/Signal Phase Control DC Fan On/off
RY-PWR RY-C/COMP
CN_LEV3
R10M 10K IC05M 74HC245AF
RY-P/ICE RY-HEATER QE A0 A1 C01M 104
2012
7 1
A0
+15V
+5V
R13Z~R15Z : 20 1/4W
5
D01Z~D03Z : 1N4937
6
+15V D01Z R13Z R11P~R13P 15K 1/4W 1% C04P 104 CN-WRITER IC01P KIA339A
RX_JIG_PC
1 2
TX_JIG_PC
C04M 104
1 2 3
FAN FG
32
VCC VCC(WH)
P
VB
VB(W)
20
VCC
22
2012
IC08M KIA65084
LEV3
21
+
C08Z
TXD-6
C01P~C03P 331
2012
31
VS(W)
W
VS IN
+5V R02A IC01A 100 2012 KIA7036P 3 C01A 3.3UF,50V RESET OSC01B 4MHz R01B 0 2
+
19
CS
CS-2
18
B0
18
20
1
C03A 104
23
D02Z R14Z
VB
VB(V)
18 17
YL
1 1
WCN-W YL
VCC VCC(VH)
OUT
COM COM(H) C09Z C10Z +5V +5V
+
R01T 4.7K
P24/AN24 P25/AN25 P26/AN26 P27/A7 Vss P30/A8 Vcc2 P31/A9 P32/A10 P33/A11 P34/A12
IC02M KID65004AP
1 2 3
RY-FAN(B)_H
4 5 6 7 8
17
B1
17
16
B2
16
CN_LEV4
15
B3
15
14
B4
14
BL
2 2
WCN-V BL VS
30
16 15 19
D03Z R15Z R07Z R08Z 4.7K 2K R02Z R09Z 2K R10Z 4.7K R11Z 2K R12Z 4.7K R01Z
V
IN VS(V) IN(VH)
+5V
RY-FAN(B)_L PSC(On/off) RY-FAN(A)_H RY-FAN(A)_L
9 10
B5 13 +5V B6
13
LEV4
12
12
RD
3
VB VCC VCC(UH) VB(U)
WCN-U RD
13 12
11
B7
11
10
OUT
COM C11Z IN(UH) C12Z R16Z 20A :47,1/4W,1% 30A :56,1/4W,1% R04Z R05Z R06Z R01Z~R06Z 100 2012 R20Z 390, 2012 3.9K,1/4W,1% C13Z 102K,2012 R17Z R03Z IN
+
PWM
ENABLE1
29
U VS
VS(U)
P35/A13
8
P36/A14 P37/A15 P40/A16 P41/A17 P42/A18
9
CS-2
ENABLE3
11 14
R11M 10K
CS-3
CN_LEV5
C02M 104
2012
+5V
+15V
1
IC06M 74HC245AF
QE +5V RX-CC TX-CC R02T 4.7K
P43/A19 P26 39 P25 40 P23 42 P22 43 P21 44 P51 45 P46 48 P45 49 P44 P47 47 P60 P61 37
C05M 104
1
OUT(WL)
28
10 9 8
C14Z 104,2012
CSC
20
VCC A0 A1
IC09M KIA65084
2
LEV5
19
CS
4
50 35 38 36 46 32 33 34 41 31
3
CS-3
18
B0 A2
RXD-5 TXD-5 RXD-4 TXD-4 RXD-3 TXD-3 RXD-2 TXD-2 RXD-1 TXD-1
18
5
4
7 6
C01Z 471 C02Z 122 C03Z 471 C04Z 122 C05Z C06Z 122 471
27
IN(WL)
Nv
17
B1 A3
RX_Flash TX_Flash
17
16
16
CN_LEV6
Inv._COMP_BLDC Nu IN(UL)
25 NC
IN(UL)
5 4
15
B3
15
14
B4
14
26
13
B5
13
3
IC01K TLP421(Dip)
1 4
LEV6
COM(L) VCC
R18Z 4.7k
2012 2012
COM(L) 2
VCC(L)
12
B6 GND R06K
AC_COM
12
4
10
24 NC 1
11
B7
680
11
5
+5V R01C 12K,1% C06K 102K
2012 2012
2 3
5
ZD03K 68V
+5V
10
IC02K TLP421(Dip)
4 1
+5V
R12K 1.5K 1/4W 1% Phase Freq R03C 10K,1% C07K 102K Q01C KTC3198Y (DIP) TRANS1 50Hz,DC12V R04C 4.7K,1/4 1% R02C 47K,1/4 1% C01C 103K 50V
2012
R14K 30K 1W
3 2
R06T 1K
D03K
R05T 4.7K
R01M~R08M 68K
R07K
680
2012
2 3
RX_JIG_PC
RX
CN_JIG_PC
VDC
TX_JIG_PC
AC_COM
TX
2 2 3 3
ZD04K 68V 3 AC(L) BD01C DF08M 5
~
+5V
C08K 102K +5V D02C 1N4148 D01C 1N4007
+
CN-COIL2
4
2012
4
+5V
2) A6UW406FA0/A7UW486FA0/A8UW566FA0
IC04K TLP421(Dip)
4 1
D1
R16K 30K 1W
R07T 1K
RX_JIG_S
D04K R11K 10K R05C 12K,1% R06C 2.7K,1% C02C 102
+
2012
RX
1
R17K 30K 1W
2012
CN_JIG_S
CN-COIL1 AC (L1) D4
~
+5V
IC05K TLP421(Dip)
1 4
R08T 10K
TX_JIG_S
TX
2012
AC_COM
2 2 3 3
ZD05K 68V
+5V
+5V
D3
4
IC06K TLP421(Dip)
4 1
R10T 1K
R26K 1.5K 1/4W 1% R18K 1K 2012
3 2
R09T 4.7K
R30K 30K 1W
RX_FLASH
RX
CN_FLASH
+5V
TX_FLASH
TX
R22K 10K
2012
+5V
+5V
IC07K TLP421(Dip)
1 4
R31K 30K 1W
AC_COM
D05K
R12T 4.7K
2 2 3 3
+5V
C05S 104
8 1
680
BD02S RBV1506
~
G D1 C09S 152J
5
BD01N DF08M
D2
D02N 1N4148
2012
+5V
IC08K TLP421(Dip)
4 1
RX
1
R27K 1.5K 1/4W 1% R32K 30K 1W
CN_CENTRAL
TX-CC
TX
2
C.T
R19K 1K 2012
Q01T KRA105
R06S 4.7K
2012
3
R01N 1K 1% 1/6W R07S 20K
2012
+
D01N 1N4148
1 4
4
C13K 102K
2012
4
R23K 10K
+5V
D4 C09S 0.1uF +120 R04S 0.05 R05S 71.5k C06S 152J D01S 1N4007
~ D3
IC09K TLP421(Dip)
1 4
R33K 30K 1W
AC_COM
D06K
+5V
CN-COM
R40K 680 C07S
2 3
1
C08S 102K IC02S TLP421 +5V +5V D01Y 1N4148 IC01V TLP421_BL D01V 1N4007 R02V~R05V 47K,1/4W,5%
2012 2012
2 3
1
ZD07K 68V 102
2012
C14K 102K
2012
+5V
IC10K TLP421(Dip)
4 1
R34K 30K 1W
2 2 3 3
TB2
R24K 10K
+5V
4 1
R35K 30K 1W
AC_COM
D07K
4 5
4 5
C4
C4
6
R41K R08V 1K
680
TXD-6
3 2
2012
2 3
6
ZD08K 68V R06V 1K,1/4 5% D01D 1N4937 C04D 470UF 35V L02D 12uH C08D 103 50V +15V C01V 102K
2012
AC_COM
C3
R01V 47K,1W,5% R07V 10K
2012
C3
C16K 102K
2012
+5V
IC12K TLP421(Dip)
4 1
RXD-6
C17K 102K
2012
R25K 10K
PTC
R37K 30K 1W
D08K
D02K 1N4007
R05K 50.5K/1W
+
IN GND
R02D
+
2K 1/2W
R102
1
R101
13
C101
Q03F
R06F 4.7K
1/4W
NF02J AC (L)
FAN FG
ZNR01J,02J SVC561
C01K 102/100V
NF01J J51~J56
J21~J26
OUT NC +15V +5V R01F RY-PWR G4A-1A-PE C07J 472M
3
D
D201
12
OUT
IC04D
1K
2012
C09J
R04J R03F 4.7K R05F 10K AC (L1) 1uF/ 275VAC C04J 1M 1UF 1/2W
9
NC
7805
RY-FAN(A)-H JQ1A-12V
R202
RY-FAN(A)-L JQ1A-12V
C06D 103
PC201
C07D 103
BP
C102
RY-FAN(B)-L JQ1A-12V
R02F PWM
S
PC201
RY-FAN(B)-H JQ1A-12V
5 6
FB
TNY 268
Q02F
R201
2012
2012
+
50V
D202
50V
Q04F 1K
2012
C08J 472M
C06J 332M
275VAC
6.8V ZD01F
RY-P/ICE G5NB-1A
RY-4WAY G5NB-1A
RY-HEATER G5NB-1A
RY-OIL/S G5NB-1A
AC (N)
7
GND u-POWER MODULE uRM1515-2B C10D 102M GND C01D 1000UF 35V C02D 470uF 25V
Q01F,02F KRC104S(Chip)
Q03F,04F KRA106S(Chip)
RY-C/COMP G4A-1A-E CN-PRESS Vs CN-MOTOR1 7 7 YL 6 6 BL FG 5 5 WH Vcc 4 4 BK GND 3 3 2 2 1 1 RD CN-FAN(A) CN-FAN(B) CN-P/ICE CN-4WAY CN-HEATER CN-OIL/S CN-HOT GAS
R03J 20 1/4W,5%
J27~J32
R02J 20 1/4W,5%
J57~J62
R01J
20
1/4W,5%
SURGE DA-38-302MT-A21
2 2
1 1
4 4
3 3
2 2
1 1
3 3
2 2
1 1
2 2
1 1
2 2
1 1
2 2
1 1
2 2
1 1
2 2
1 1
BK
WCN_GND2
BK
WCN_GND1
H/P
L/P
DC FAN MOTOR
FAN MOTOR(L)
FAN MOTOR(R)
COMP (single)
COMP_AC_IM
R21K 1K 2012
R36K 30K 1W
ZD01K,02K 36V,1W
C2
C2
C02K 150uF/100V
CN-CP(L)
CN-CP(N)
C1
C1
20A/250V
FUSE
WCN_P(L) BR
C02J
222M
C01J 1uF/
275VAC
C03J
GR/YL
222M
GND GND
WH
WCN_P(N) BL
BK
TB1
AC-POWER AC220~240V/50,60Hz
7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
VDC
BUS_ADDR_LEV
R01M 10K
5V
C01M 104
12V
1
IC05M KIA65084 IC01M QE A0
CN_LEV 5
BUS_COM 5V
DC310V R01K 1.5K
ERA15-06
IC02K(TLP627)
1 VCC
18
3 1 2
A1 245
3 20 19 3
A2 A3
2 CS_LEV12
17
3 B0
16
TX_D0
IC01K(TLP621)
D01K D07K ERA15-06
5 18 4 5
A4 A5
LEV5
4 B1
15
6 17 16 6 15 7 14
RX_D0
R07K,IK
R19K 1K
R25K 82K/3W
CN-DATA
1 2 3 4 2 3 4 5 6 5 6 1
C07B 103
B2 B3 B4 A6 A7 GND
CN_LEV 6
2
B5
14
3 8 9 10 13 12 11
B6 B7
13
TX_D1
IC03K(TLP621)
D02K D08K ERA15-06
12
LEV6
11
10
C08B 103
RX_D1
C04K 102 25V R14K 10K IC06K(TLP627) R03K 1.5K
ERA15-06
R08K,IK
R20K 1K
R26K 82K/3W
R02M 10K
5V
C002M 104
12V
1
IC06M KIA65084 IC02M
CN_LEV 3
TX_D2
IC05K(TLP621)
D03K
1 QE VCC
18
3 1
A0 A1 A2 A3
3 20 2
245
2 CS_LEV12
17
4 19 3 4 5
A4
3 B0
16
RX_D2
C06K 102 25V R15K 10K IC08K(TLP627) R04K 1.5K
ERA15-06
R09K,IK
R21K 1K
R27K 82K/3W
D09K ERA15-06
5 18 17 16 6
A5 A6
LEV3
4 B1 B2
15
C09B 103
1 15 7 14 8 13
B3 B4 B5
CN_LEV 4
TX_D3
IC07K(TLP621)
14
3
D04K
3
A7
R28K 82K/3W D10K ERA15-06
13
4 9
GND
4 12 10 11
B6 B7
12
RX_D3
C08K 102 25V R16K 10K IC10K(TLP627) R05K 1.5K
R10K,IK
R22K 1K
LEV4
11
10
C10B 103
TX_D4
ERA15-06
R03M 10K
IC09K(TLP621)
D05K D11K ERA15-06
5V
C003M 104
12V
1
R29K 82K/3W
1
IC07M KIA65084
CN_LEV 1
R23K 1K
2
IC03M QE
1 VCC
18
RX_D4
C10K 102 25V R17K 10K
17
4
IC12K(TLP627) R06K 1.5K
ERA15-06
4 1
A0 A1 A2
20 2
245
16
19 3 4
IC11K(TLP621)
A3
D06K
CS_LEV12
5 18 17 5
A4 B0 B1
LEV5
15
TX_D5
C11B 103
16 6
R12K,IK R24K 1K
R30K 82K/3W D12K ERA15-06
B2
1 15
A5 A6 B3 B4
CN_LEV 2
7 14
2
B5
14
RX_D5
C12K 102 25V 25V
3
R18K 10K
3 8
A7 GND
13 9 10 12 11
6 B6 B7
13
12
LEV6
11
10
C12B 103
R11K,IK
Schematic Diagram
Schematic Diagram
13
C101 R101
GND
R102
IN
+12V
D101
IC04D
7805
9
D201 R201 R202 PC201
L1 12uH
12
OUT
D
OUT
3 NC
TNY 267
FB
BD01D DF08M
N/F01N 11mH/1.5A
ZNR01N SVC561D-14A
FUSE_1 250V/T3.15A
+
1/4W
S
C102
5 NC 6
1K
7
D202
CN_PWR
D05D 1N4007
D05D 1N4007
D05D 1N4007
5V_EXT
5V 5V
C09Y 104 U05Y MAX253 Trans01Y D01Y SS12 G C04Y 22uF/35V IC03D KID78L05BP I O 7805 C02Y 104 C03Y 22uF/35V C05Y
R13K 1K/0.62K
1 2 3 4
6N137
4.7K R14K
4 5 6
D02Y SS12
1 2 3 4
2 3
U02Y 6N137
8 7 6 5
104 C01K
5
IC02K(6N137)
TXD1
CN_OUT
5V
1 2 3 4
C07Y 104 R02Y 5.1K 104
8 7 6 5
CN-COMM
1 2 3 4 4 3 2 1
TXD1
15pF C03K
RX
1 2 3 4
8 7 6 5 1 2 3 4 8 7 6 5
SEL
R12K 1K/4.7k
5
TX
TXD0
SEL SCK
5V
2012
2012
IC01K(6N137)
5V
5V_EXT
BR1
1 o o 2 3 o o 4 5 o o 6 7 o o 8
CON5*2
RXD0
44
43 MOSI 1 MISO 2
42
41
40
39
38
37
36
35
SEL
9 o o 10
TXD0
LED01G
5V 5V
LED02G LED03G
R02A 4.7K
5V
1
R03A 120
R01A 1K
IC01A 3.6V
4.7uF
ATMEGA162
RXD0 5
5V
PA7
R04T 10K
2012
AGND
SWITCH
V5
R02M 1K OMRON_B3WN
OUT
8 7 6 2 3 4
PD5
11 12
4*K1 W8/1
ON
5 1
SW DIP-4
V5
PD4
10
24
R05T 10K
S80R S70R S60R S50R
C05H
C04H
C03H
C02H
4*K01 W8/1
4*301
V5
R06T 10K
R01B
C03X 104,2012
1M
C02X 102K
12uH L01D 12uH L02D
R03X 1K
2012
OSC01B 14.7456
2012
5V
6N137
C01X 102K
R01X 1K
104 C02K
RXD0
RXD1
5 6 7 8
4 3 2 1
R06Y 0.62K
15pF C04K
RXD1
GND
5V_EXT
12V_EXT
R15K 1K/0.62K
5V_EXT
IC05D
7805
CN_JIG
TXD2
RX
RXD2
TX
GND
5V
C04X 104
5V
5V
Schematic Diagram
Wiring Diagram
1. Room Type Indoor Unit
AC PCB ASM
CN-MOTOR
DC PCB ASM
CN-U/D CN-TH1 CN-TH2 THERMISTOR(OUT-PIPE) THERMISTOR(IN-PIPE) THERMISTOR(ROOM)
FAN MOTOR
WH BK YL RD
AC PWB ASM
CN-MOTOR1 CN-GND1
DC PWB ASM
STEP MOTOR
CN-ACDC1
CN-ACDC2
ZNR
ZNR
Z
CN-POWER
GN/YL
BR
BL
RD
FUSE 250V 2A
H.V. ASM BK
1(L) 2(N)
CN-D1(WH) CN-D2(WH)
CN-POWER
TO OUTDOOR UNIT
3854A20135Y
3854A20135W
STEP MOTOR
FORCE S/W
CN-MOTOR
CN-L/R
WIRING DIAGRAM
STEP MOTOR
ROOM. IN-PIPE. OUT-PIPE. CENTRAL CONTROL REMOTE TELE CONTROL THERMISTOR CONTROL THERMISTOR THERMISTOR DRY CONTACT A/CL UNIT PTC HEATER
OR
MOTOR
SH-CAPA
CN-U/D
BK
BR YL GN/YL
CN-PIPE1
CN-REMO CN-PIPE2
CN-ROOM
CN-AIRC
CN-PTC
CN-OUT
STEP MOTOR
ZNR CN-HVB
VENTILATION E/HEATER
RD
H.V.B
RD
A/CL
CN-ZONE
BK
BK
CN-TH2
FLOAT S/W
THERMISTOR(OUT-PIPE)
CN-PIPE1
GN/YL BR
FUSE
CN-DISP CN-MOTOR CN-DPUMP CN-POWER
CN-TH1
THERMISTOR(IN-PIPE) THERMISTOR(ROOM)
CN-POWER
FUSE 250V 2A
BR BL GN/YL RD
CN-VFD
DISPLAY
RF-REMOTE CONTROL
OPTION
1(L) 2(N)
3 4
3854A20419A
TO OUTDOOR UNIT
CN-MAIN CN-SW/1
CONNECTOR PCB ASM
CN-SW/2 CN-SW/3
CN-STEP1
CN-STEP2
1(L) 2(N)
BL
RD
TO OUTDOOR UNIT
Schematic Diagram
5. Duct Type Indoor Unit - BH/BP chassis 6. CVT Type Indoor Unit - VE chassis
WIRING DIAGRAM
ROOM. IN-PIPE. OUT-PIPE. CENTRAL CONTROL REMOTE TELE CONTROL THERMISTOR CONTROL THERMISTOR THERMISTOR DRY CONTACT
WIRING DIAGRAM
A/CL UNIT PTC HEATER
CN-DOOR
STEP MOTOR
S/W2
CN-UD1
CN-OUT
CN-PIPE1
CN-REMO CN-PIPE2
CN-ROOM
CN-AIRC
CN-PTC
VENTILATION E/HEATER
S/W1
DC PCB ASSY
CENTRAL CONTROL
CN-CC
AC PCB ASSY
4 RD GN/YL 1(L) 2(N) BL BR TO OUTDOOR UNIT
A/CL UNIT
CN-ACDC
RD
FLOAT S/W CN-PIPE1
TO OUTDOOR UNIT
HVB CN-HVB
CN-ACDC
GN/YL
FUSE
CN-TH1 CN-TH2 CN-FLOAT CN-DISP CNMOTOR CNDPUMP
OPTION
OPTION
RF-REMOTE CONTROL
3854A20419D
3854A20419B
CENTRAL CONTROL
CN-DOOR
DOOR S/W
A/CL UNIT
WIRING DIAGRAM
HVB
STEP MOTOR
S/W2 S/W1
CN-CC
STEP MOTOR
STEP MOTOR
CN-HVB
RD GN/YL BL BR
TO OUTDOOR UNIT
CN-ACDC
CN-ACDC
FUSE
CN-TH1 CN-TH2 CN-FLOAT CN-DISP CNMOTOR CNDPUMP
CN-HVB
OPTION
CN-REMO
3854A20419E
OPTION
REMOTE CONTROL
3854A20419C
CAPACITOR BR YL BK GN/YL
INDOOR MOTOR CN-ROOM CN-MOTOR CN-PIPE1 CN-FLOAT PIPE OUT THERMISTOR CN-PIPE2
OR
CN-DPUMP
CN-STEP
GN/YL
DRAIN PUMP
CN-REMO
CN-AIRC
BR BL
1(L) 2(N)
RD
WH RD
BK
TO OUTDOOR UNIT
H.V.B
RD BK
P/N:3854A20405A
AIR CLEANER
DOOR S/W
(OPTION)
CN-DISP
1(L) 2(N)
HVB
TO OUTDOOR UNIT
CN-CC
Schematic Diagram
2. A3UW246FA0
OUTDOOR WIRING DIAGRAM
INVERTER COMPRESSOR REACTOR RD BL YL
OR
RD BL YL
RD
BL
YL
BK
BK
CN-FAN(A)
BL BK BR YL
OR
FAN
RD
BL
YL
BK
BK
CN-FAN(A)
CN-LEV2 CN-LEV1
CN-COIL1 CN-COIL2
BL BK BR YL
FAN
LEV
MAIN PCB
4WAY VALVE
LEV
CN-LEV2 CN-LEV1
LEV
CN-COIL1 CN-COIL2
LEV CN-4WAY
4WV
CN-4WAY CN-LEV3
LEV
MAIN PCB
CN-HEATER
CN-TH2 CN-TH1 CN-TH3 CN-TH4
CN-JIG-PC CN-CENTRAL
CN-JIG-PC CN-CENTRAL
CN-WRITER
CN-TH2
CN-TH3
CN-WRITER
CN-TH1
CN-P/ICE
(H/SINK) (AIR/PIPE) (DISP-I/SUG) (DISP-C)
SV (HEATING)
DEFROST
(AIR/PIPE)
CN-PRESS CN-OIL/S WH RD
CN-COM L N
BK
RY-C/COMP
CONSTANT
BR BL RD
GND-1 GND-2 BR BR BL BK BK BL
BR
BL
BL BR
BL BR
1(L) 2(N) 1(L) 2(N) 3(A) 3(B) 1(L) 2(N) 3(L) 4(N) 5(A) 5(B) 3(L) 4(N) 5(C) GN/YL
POWER SUPPLY
A ROOM B ROOM
TO INDOOR UNIT
POWER SUPPLY
3854A20354A
TO INDOOR UNIT
3854A20354B
3. A4UW306FA0
INVERTER COMPRESSOR
4. A6UW406FA0
INV-COMP
WIRING DIAGRAM
RD BL YL
REACTOR
OR
RD
OR
CN-LEV1
BL
YL
BK
BK
CN-FAN(A)
BL BK
BR
RD
BL
YL
BK
BK
CN-FAN(A)
FAN(B)
LEV
CN-CENTRAL
CN-FAN(B)
CN-WRITER
CN-COIL1 CN-COIL2
BL BK BR YL OR BL BK BR YL
FAN(A)
LEV
CN-COIL1 CN-COIL2
YL OR BL BK
BR
MAIN PCB
TH2 TH1 TH3 TH4
CN-FAN(B)
YL
CN-4WAY
YL
4WV
CN-4WAY
CN-LEV3
CN-JIG-PC
MAIN PCB
CN-COM
CN-HEATER
(H/SINK) (AIR/PIPE) (I/SUC-DISP) (DISP-C)
CN-HEATER
CN-TH2 CN-WRITER CN-TH1 CN-TH3 CN-TH4
CN-CENTRAL
CN-OIL/S
WH BK NOISE FILTER RELAY WH
SV OIL SEPERATOR(INV)
LOW PRESSURE SWITCH CONS-COMP
BL RD BR R S C
CN-PRESS
CN-P/ICE
(H/SINK) (AIR/PIPE) (DISP-I/SUG) (DISP-C)
SV
FUSE 250V,20A
CN-JIG-PC
GND-2
GND-1
BR
BR
BL
SV OIL SEPERATOR
BL BR BR
BL
GN/YL BL BR
CONSTANT COMPRESSOR
BR BL RD C R S
GN/YL BR
T/B
CN-COM L N WH RD BK BR BL BL
1(L) 2(N)
1(L) 2(N)
3(A) 3(B)
GND-1 GND-2
Power Supply
LEV A LEV B LEV C LEV D LEV E LEV F
BR
BL
BR
BL
BL BR
CN-LEV-A
LED1
CN-LEV-B
LED2
CN-LEV-C
LED3
CN-LEV-A
LED1
CN-LEV-B
LED2
CN-LEV-C
LED3
1(L) 2(N) 3(L) 4(N) 5(A) 5(B) 3(L) 4(N) 5(C) 5(D)
BRANCH DISTRIBUTOR-(A)
CN-ROOM-A CN-ROOM-B CN-ROOM-C L N S L N S L N S L N S CN-PWR
BRANCH DISTRIBUTOR-(B)
CN-ROOM-A CN-ROOM-B CN-ROOM-C L N S L N S L N S L N S CN-PWR
POWER SUPPLY
TO INDOOR UNIT
3854A20354C
TO INDOOR UNIT
TO INDOOR UNIT
3854A20354G
Schematic Diagram
5. A2UW146FA0
INVERTER COMPRESSOR
6. A3UW186FA0
OUTDOOR WIRING DIAGRAM
INVERTER COMPRESSOR
RD BL YL
REACTOR
RD BL YL
OR
RD
BL
YL
BK
BK
CN-FAN(A)
BL BK BR YL
OR
FAN
RD
BL
YL
BK
BK
CN_FAN(A)
CN-LEV2 CN-LEV1
CN-COIL1 CN-COIL2
BL BK BR YL
FAN
LEV
MAIN PCB
LEV
CN-4WAY
4WV
4WAY VALVE
CN_LEV2 CN_LEV1
LEV
CN_COIL1 CN_COIL2
LEV LEV
CN_4WAY CN_LEV3
MAIN PCB
CN_TH2 CN_TH1 CN_TH3
CN-JIG-PC CN-CENTRAL
CN-PRESS
CN_JIG_PC CN_CENTRAL
CN-WRITER
CN-TH2
CN-TH3
CN_WRITER
CN-TH1
CN_PRESS
CN_COM
N CN-GND1 CN-GND2
L N GND_1 GND_2
BR
BL
WH
BK
BK
BR BL
BR
BL
BK
BL BR
WH
BK
BL BR
GN/YL
POWER SUPPLY
A ROOM B ROOM
TO INDOOR UNIT
POWER SUPPLY
RD
CN-COM
3854A20354L
TO INDOOR UNIT
3854A20354J
7. A4UW246FA0
INVERTER COMPRESSOR
8. A7UW486FA0, A8UW586FA0
INV-COMP(A)
WIRING DIAGRAM
RD BL YL
REACTOR
RD
OR
CN-LEV1
OR
BL
YL
BK
BK
CN-FAN(A)
BL BK
BR
YL
FAN (A)
4WAY 4WV VALVE CONS-COMP(C)
BR C BL R S
RD
RD
BL
YL
BK
BK
CN-FAN(A)
BL BK BR YL
FAN
LEV
CN-COIL1 CN-COIL2
CN-4WAY
CN-WRITER
CN-LEV2 CN-LEV1
CN-COIL1 CN-COIL2
CN-CENTRAL
MAIN PCB
TH2 TH1 TH3 TH4
CN-C/COMP2
LEV
CN-HEATER
BR
BL
LEV LEV
CN-LEV3
MAIN PCB
CN-HEATER
CN-TH2 CN-TH1 CN-TH3 CN-TH4
CN-COM
CN-JIG-PC
CN-4WAY
CN-HEATER2 CN-C/FAN
CN-JIG-PC CN-CENTRAL
FM COOLING FAN
OIL
NOISE FILTER
CN-OIL/S
SV SEPERATOR
LOW PRESSURE SWITCH CONS-COMP(B)
WH BL BL BL C R S
RD
CN-WRITER
CN-P/ICE
(AIR/PIPE) (H/SINK) (DISP-I/SUG) (DISP-C)
FUSE 250V,20A
CN-PRESS
GND-2
BK
GND-1
BK
RY-C/COMP BR
CN-PRESS CN-OIL/S RD WH
BR
SV OIL SEPERATOR
OLP COMPRESSOR
C R S
GN/YL BL BR GN/YL
BL
T/B
BR
CN-COM L N
BK
RY-C/COMP
CONSTANT
T/B
BR BL RD
1(L) 2(N)
1(L) 2(N)
3(A) 3(B)
GND-1 GND-2 BR BR BL BL
LEV A
Power Supply
LEV B LEV C LEV D LEV E LEV F LEV G LEV H
BL BR
BL BR
CN-LEV-A
LED-1
CN-LEV-B
LED-2
CN-LEV-C
LED-3
CN-LEV-D
LED-4
CN-LEV-A
LED-1
CN-LEV-B
LED-2
CN-LEV-C
LED-3
CN-LEV-C
LED-4
1(L) 2(N) 3(L) 4(N) 5(A) 5(B) 3(L) 4(N) 5(C) 5(D)
BRANCH DISTRIBUTOR-(A)
CN-ROOM-A CN-ROOM-B CN-ROOM-C CN-ROOM-D L N S L N S L N S L N S L N S CN-PWR
BRANCH DISTRIBUTOR-(B)
CN-ROOM-A CN-ROOM-B CN-ROOM-C CN-ROOM-D L N S L N S L N S L N S L N S CN-PWR
POWER SUPPLY
TO INDOOR UNIT
3854A20354M
TO INDOOR UNIT
TO INDOOR UNIT
3854A20354K
Schematic Diagram
Components Locations
1. Indoor Unit
MAIN P.C.B ASM 1) Split Type DC part
AC part
JP12
CN
TOP VIEW
JP56
-V
JP48
D(W
JP55
H)
Schematic Diagram
C01G R01G R03V C03V JP47 JP46 C02H R21H R23H R22H R02H R01H R05H R04V C04V JP4
JP54
BOTTOM VIEW
C01X
OR2H
JP53
L01X
JP49
R06H C01H
N-T
L02X
R01B
JP52
JP51
JP19
JP23
20
IC02M
R01A C01A
R02A JP50
25 30
IC04D
R01P
JP42 C07D
C09D
Q01C
CN-L/R(BL)
IC04M
JP38
ZD02D
CN-CC
FUSE
250V/T2A
JP22
IC1
JP41
C08D
JP10
JP8 R01L
Q01V
JP17
R08D
JP37
R03D R02D JP34 JP27 JP20 JP35 SMPS C01D SD01D JP33 R24G R23G NTC R22G R21G IC01D
C02D
R06D D05D
CN-CH2
JP30
EARTH
D02D
ZNR01J
R03J
JP7 JP6
R04J
R05K
Q01K
R01K
D01K CN-POWER
40
H1
JP45 C01F
CN
55
JP58
10
-H VB (B
50
15
L)
JP57 R02F R01F
JP44
CN
IC01A JP14
-S
MICOM
UC (W H) CN -U /D (W H)
JP43 IC01M
IC02D
BC01D
IC03D
IC01J
JP13
C01K
IC02K
IC01K
Schematic Diagram 4) Duct Type High static (BH/BG chassis) Built in type (BP chassis)
58 B
TOP VIEW
BOTTOM VIEW
DC part
TOP VIEW
BOTTOM VIEW
PWB ASM:6871A20390
PCB:6870A90065K
BOTTOM VIEW
VB chassis
TOP VIEW
BOTTOM VIEW
BOTTOM VIEW
Schematic Diagram
3. Outdoor Unit
1) Component side
2) Bottom View
Schematic Diagram
BOTTOM VIEW
OUTDOOR UNIT
Room C
Room B
Troubleshooting Guide
Accumulator
Room C LEV-B
Room B
Room A
Troubleshooting Guide
Drier
OUTDOOR UNIT
Troubleshooting Guide
Cooling
Drier
Heating
Valve(2) Solenoid
Refrigerant Flow
Valve(1) Solenoid
2. A3UW246FA0, A4UW246FA0
OUTDOOR UNIT
Reversing Valve
Room D
3. A4UW306FA0
Room C
Room B
Room A Header Check Valve(2) Oil Seperator Th2 Accumulator Th1 Heat Exchanger Check Valve(1)
Field Piping
Room C
Liquid
Room B
Room A
Cooling
Drier
Troubleshooting Guide
Heating
Valve(2) Solenoid
Refrigerant Flow
Valve(1) Solenoid
Room D
Troubleshooting Guide
4. A6UW406FA0
OUTDOOR UNIT
Refrigerant Flow Cooling Heating
Reversing Valve
Solenoid Valve(1)
Heat Exchanger
Constant Compressor
L.E.V.
Receiver
Troubleshooting Guide
5. BD Unit
Refrigerant Flow Cooling Heating Main Liquid Main Gas Piping ( 9.52) Piping ( 19.05)
[Indoor Unit]
LEV-D
LEV-C
Outdoor Unit
Troubleshooting Guide
Self-diagnosis Function
s Error Indicator The function is to self-diagnoisis airconditioner and express the troubles identifically if there is any trouble. Error mark is ON/OFF for the operation LED of evaporator body in the same manner as the following table. If more than two troubles occur simultaneously, primarily the highest trouble fo error code is expressed. After error occurrence, if error is released, error LED is also released simultaneously. To operate again on the occurrence of error code, be sure to turn off the power and then turn on. Having or not of error code is different from Model.
Indoor Error
Error code 00 01 02 03 04 05 06 07 No Error Indoor Room themistor error Indoor in-piping sensor error Remote controller error Drain Pump error Communcation error between in and out Indoor Out-Piping sensor error Differnt mode operation 1time 2times 3times 4times 5times 6times 7times Description INV TPS LED 1 (Red) LED 2 (Green) Indoor Status ON OFF OFF OFF OFF OFF OFF OFF
Outdoor Error
Error Code
21 22 23 24 25 26 27 28 32 33 40 41 44 45 46 47 51 53 60 61 62 63 65 CT 2(Max CT) DC Link Low Volt. L_P/Heater Sink Low voltage / Over voltage DC Comp Position Error PSC Fault Error DC Link High Volt D-Pipe High (INV) D-Pipe High (Normal) CT Sensor (Open/Short) INV. D-PipeTh Error(Open/Short) Outdoor air Th Error(Open/Short) Cond. Pipe Th Error(Open/Short) Suction Pipe Error(Open/Short) Const D-pipe Th Error(Open/Short) Capacity over Signal error (Indoor Outdoor) EEPROM Check Sum Error Cond. Pipe High Heatsink High Cond. Pipe Low Heatsoml Th error (Open/Short)
Description
DC Peak (IPM Fault)
INV TPS
LED 1 (Red)
2times 2times 2times 2times 2times 2times 2times 2times 3times 3times 4times 4times 4times 4times 4times 4times 5times 5times 6times 6times 6times 6times 6times
LED 2 (Green)
1time 2times 3times 4times 5times 6times 7times 8times 2times 3times O 1time 4times 5times 6times 7times 1time 3times O 1time 2times 3times 5times
Indoor Status
OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF
Troubleshooting Guide
Temp. Difference Temp. difference Current Operating Current Temp. difference Current : less than 8C : near the rated current Excessive amount of refrigerant : approx. 8C : less than 80% of rated current Refrigerant leakage Clog of refrigeration cycle Defective compressor
Temp. difference
: over 8C
Normal
Notice: Temperature difference between intake and discharge air depends on room air humidity. When the room air humidity is relatively higher, temperature difference is smaller. When the room air humidity is relatively lower temperature difference is larger. 2. Check temperature and pressure of refrigeration cycle. Suction pressure (Compared with the normal value) Temperature (Compared with the normal value) High Higher Normal Excessive amount of refrigerant Insufficient amount of refrigerant(Leakage) Clogging High pressure does not quickly rise at the beginning of operation. Current is low.
Lower
Higher
Notice: 1. The suction pressure is usually 4.5~6.0 kg/cm G at normal condition. 2. The temperature can be measured by attaching the thermometer to the low pressure tubing and wrap it with putty.
2
Troubleshooting Guide
Trouble 1
Turn off the main power and wait until LED on outdoor PCB is off.
Does "Beeping" sound is made from the indoor unit? NO Check the voltage of power(AC220V/AC240V, 50Hz). The voltage of main power. The voltage applied to the unit. The connecting method of Indoor/Outdoor connecting cable (each color) The P.W.B. Ass'y (Fuse, Noise Filter, Power Transformer, IC01D, IC02D, etc.) YES Primarily, the operating condition of Micom is O.K.
Check CN-DISP1
The operation check of the P.C.B. Ass'y Procedure 1) The input voltage of power transformer. 2) The output voltage of power transformer. 3) IC01D(7812) 4) IC02D(7805) 5) IC01A(KIA7036) Specification 1) AC230V 30V : Check the rated voltage 2) 14V 3V 3) DC12V 4) DC5V 5) The voltage of micom pin 29 : DC4.5V Remedy 1) Replace power transfomer. 2) Replace power transfomer. 3) Replace IC01D. 4) Replace IC02D. 5) Replace IC01A.
Troubleshooting Guide
Trouble 2
While the compressor has been stopped, the compressor does not operate owing to the delaying function for 3 minutes after stopped.
When the compressor stopped Indoor Fan is driven by a low speed. At this point the wind speed is not controlled by the remote controller. (When operated in the Sleeping Mode, the wind speed is set to the low speed as force.)
When the detect switch (double key) inside the remote controller door is fault, it is impossible to operate temperature regulating(v / w) and wind speed selecting.
Troubleshooting Guide
Trouble 3
Operate Cooling Mode by setting the disired temperature of the remote controller is less than one of the Indoor temperature by 1C at least.
Check the sensor for Indoor temperature is attatched as close as to be effected by the themperature of Heat Exchange (EVA.)
When the sensor circuit for Indoor temperature and connector are in bad connection or are not engaged, Compressor/Outdoor fan is stopped. Check the related circuit of R02H(12.1K), R01H(1K), R04H(6.2K), R03H(1K), C01H(102), C02H(102), Micom(pin No. , ). Check the Indoor temperature sensor is disconnected or not (about 10K at 25C).
Check the Relay(RY-PWR, RY-START) for driving Compressor. Check the voltage between brown and blue cable of terminal to connect the Outdoor (About AC220V / 240V). Check the related circuit of relay in Outdoor PCB Ass'y. Check Point Between Micom(No. 19) and GND Between IC01M(No. 10) and GND Comp. ON DC 5V DC 1V Comp. OFF DC 0V DC 12V
Check the electrical wiring diagram of Outdoor side. Check the open or short of connecting wires between Indoor and Outdoor.
Troubleshooting Guide
Trouble 4
Check the related circuit of indoor Fan Motor. The pin No. 38 of micom and the part for driving SSR.(Q01M) Check the related pattern. Check the SSR. - SSR Open: Indoor Fan Motor never operate. - SSR short: Indoor Fan Motor always operates in case of ON or OFF.
Check the SSR high speed operation by remote control. (the Indoor Fan Motor is connected) The voltage of Pin No 1(orange) and 3(black) of CN-FAN.
Check SSR
Troubleshooting Guide
Trouble 5
Confirm that the vertical louver is normally geared with the shaft of Stepping Motor. If the regular torque is detected when rotating the vertical louver with hands Normal
Check the connecting condition of CN-U/D or CN0L/R Connector Check the soldering condition(on PCB) of CN-U/D or CN0L/R Connector
Check the operating circuit of the vertical louver Confirm that there is DC +12V between pin of CN-U/D, CN0L/R and GND. Confirm that there is a soldering short at following terminals. - Between 17 , 18 , 19 and 20 of MICOM - Between 1 , 2 , 3 and 4 of MICOM - Between 4 , 5 , 6 and 7 of IC01M - Between 5 , 6 , 7 and 8 of IC01M
If there are no problems after above checks. Confirm the assembly condition that are catching and interfering parts in the link of the vertical louver
Troubleshooting Guide
General Information
s Error Indicator (Indoor) The function is to self-diagnosis air conditioner and express the troubles if there is any trouble. Error mark is displayed on display window of indoor units and wired-remote controller, and LED of outdoor unit control board. If more than two troubles occur simultaneously, lower number of error code is first displayed. After error occurs, if error is released, error LED is also released simultaneously.
1 digit
s Indoor Error Error code 01 02 03 04 05 06 07 Contents Air sensor (open/short) Inlet pipe sensor
10 digit
Case of error Open / Short Open / Short Communication Poorly Float switch Open Communication Poorly Open / Short Different operation mode
Communication(Indoor Wired R/Control) Drain pump/ Float switch Communication(Indoor Outdoor) Outlet pipe sensor Different operation mode
Troubleshooting Guide
s Error Indicator (Outdoor) Outdoor Error Ex) Error 21 (DC Peack)
2 Times 2 Times 2 Times
LED01G (RED)
1 Sec. 1 Time 1 Sec. 1 Time 1 Sec. 1 Time
LED02G (GREEN)
2 Sec. 2 Sec.
Error code
21 22 23 24 25 26 27 28 32 33
Contents
IPM Fault (Compressor Over current) CT 2(Max. Current) DC Link Low Volt. Low / High press AC Low / AC High Volt. DC Compressor Position PSC Fault DC Link High Volt Discharge Pipe Temp. High (INV) Discharge Pipe Temp. High (Cons.)
Case of error
Compressor malfunction,IPM Fault Current is 14A DC Link volt. Is 140V Low / High press switch OPEN Abnormal AC volt. Input.
Outdoor Status
Off Off Off Off Off Off Off Off Off Off
Troubleshooting Guide
s Error Indicator (Outdoor) Outdoor Error
Error code
40 41 44 45 46 47 51 53 60 61 62 65 CT Circuit
Contents
Case of error
CT Circuit malfunction Open / Short Open / Short Open / Short Open / Short Open / Short Over load combination Communication Poorly Check sum mismatching
Outdoor Status
Off Off Off Off Off Off Off Off Off Off Off Off
D-pipe sensor INV. (open/ short) Air sensor (open/ short) Cond. Pipe sensor (open/ short) Suction pipe sensor (open/ short) D-pipe sensor Cons. (open/ short) Over capacity Communication (Indoor EEPROM check sum Cond. Pipe sensor temp. high Heat sink sensor temp. high Heat sink sensor (open/ short) Outdoor)
02
Normal resistor : 5K/ at 25C (Unplugged) Normal voltage : 2.5Vdc / at 25C (plugged)
06
Normal resistor : 5K/ at 25C (Unplugged) Normal voltage : 2.5Vdc / at 25C (plugged)
10k
2.5Vdc
V
Check Point
1. Unplug the sensor on Indoor unit PCB. 2. Estimate the resistance of each sensor. 3. If the resistance of the sensor is 10K/ 5K at 25C, then sensor is normal. 4. If the resistance of the sensor is 0 K or , then sensor is abnormal. Change the sensor. 5. Plug the sensor on Indoor unit PCB and Power ON. 6. Estimate the voltage of each sensor. 7. If the voltage of the sensor is 2.5Vdc at 25C, then sensor is normal. 8. If the resistance of the sensor is 0 or 5Vdc, then sensor is abnormal. Repair or Change the PCB.
CN-REMO
12Vdc
V
12Vdc
V
Check Point
1. Check the wire connection. (Open / Short) Repair the connection 2. Check the soldering state of connector. (Soldered poorly) Repair or Change the PCB. 3. Check the volt. Of main PCB power source. (DC 12V, DC 5V) Repair or Change the main PCB. 4. Check the installation of wired remote controller. (Noise interference) Adjust the state of installation
04
CN Float
CN-D/PUMP CN-Float
Check Point
1. Check the wire connection. (Open, Soldered poorly) Repair the connection or change the PCB. 2. Check the resistance of float switch (Abnormal : Open, Normal : short) Check the float switch. 3. Check the level of water 4. Check the volt. Of Drain pump power supply. (AC 230V) Repair or Change the main PCB.
04 / 53
Communication poorly
Check Point
1. Check the input power AC230V. (Outdoor, Indoor unit) 2. Check the communication wires are correctly connected. Adjust the connection of wire Confirm the wire of Live, Neutral 3. Check the resistance between communication line and GND. (Normal : Over 2M) 4. Check the connector for communication is correctly connected. 5. Check the connection of GND1, GND2, and main GND. 6. If one indoor unit is operated normally, outdoor PCB is no problem. Check the another indoor unit. * CH05 is displayed at indoor unit, CH53 is displayed at outdoor unit.
21
DC Peak
Comp U V W
Resistance() at 20C Terminal U-V V-W W-U Copper pipe Inverter Constant comp. comp. 0.64 0.64 0.64 0.8 0.8 0.8
Comp
Resistance() at 20C Terminal U-GND V-GND W-GND Inverter Constant comp. comp. 2M 2M 2M 2M 2M 2M
Check Point
1. Check the wire connection. (U,V,W) 2. Check the load condition. (Refrigerant, Pipe length, ) Adjust the load condition 3. Check the electricity leakage of the compressor. Normal : Over 2M. 4. Check the resistance of compressor. Normal : 0.65(INV), 0.8(Cons.) No difference at each terminal. 5. Check the insulation from water at IPM part. Check the trace of water. 6. Check the IPM circuit.
Max. C/T
22
Check Point
1. Check the power source. 2. Check the fan operation is right. 3. Check the current. 4. Check the install condition. 5. Check the internal circuit. (C/T, Diode, Resistor)
+ + -
28
Check Point
1. Check the power source. 2. Check the components (B/Diode, Reactor, PSC Parts )
25
Input voltage
CN PRESS
CN TRNAS1
Check Point
CH 24 1. Check the connection of CN_PRESS 2. Check the install condition for over load. 3. Check the SVC V/V open. 4. Check the leakage of refrigerant. CH 25 1. Check the power source. 2. Check the components (Trans1, B/Diode, Diode, Resistance)
27
PSC Fault
E C B
B E
Check Point
CH 26 1. Check the connection of U,V,W 2. Check the insulation of IPM part. 3. Check the compressor. (same with CH21) CH 27 1. Check the component of IGBT 2. Check the components (IGBT, R04S, NF1, BD02S)
33
Normal Normal
Check Point
CH 32 1. Check the install condition for over load. 2. Check the SVC V/V open. 3. Check the leakage of refrigerant. CH 33 1. Check the install condition for over load. 2. Check the SVC V/V open. 3. Check the leakage of refrigerant. 4. Check the constant compressor. (same with CH21)
Troubleshooting Guide 11) Troubleshooting CH41, CH44, CH45, CH46, CH47, CH65
Display code 41 Title Cause of error Open / Short Soldered poorly Internal circuit error Open / Short Soldered poorly Internal circuit error Open / Short Soldered poorly Internal circuit error Open / Short Soldered poorly Internal circuit error Open / Short Soldered poorly Internal circuit error Open / Short Soldered poorly Internal circuit error Check point & Normal condition Normal resistor : 200K / at 25C (Unplugged) Normal voltage : 4.5Vdc / at 25C (plugged)
44
Air sensor
Normal resistor : 10K / at 25C (Unplugged) Normal voltage : 2.5Vdc / at 25C (plugged)
45
46
47
Normal resistor : 200K / at 25C (Unplugged) Normal voltage : 4.5Vdc / at 25C (plugged)
65
Normal resistor : 10K / at 25C (Unplugged) Normal voltage : 2.5Vdc / at 25C (plugged)
Check Point
1. Estimate the resistance of each sensor.(Unplugged) 2. Estimate the voltage of each sensor.(Plugged) 3. If the resistance of the sensor is 0 k or , then sensor is abnormal.
Over capacity
60
Max. single indoor unit capacity 12k 12K 18K 18K 24K
Check Point
CH 51 1. Check the indoor unit capacity. CH 60 1. Check the insertion condition of EEPROM. 2. Check the poor soldering
Check the load condition. Check the sensor of Condenser pipe sensor.
62
Normal
OFF
Normal
Check Point
CH 61 1. Check the install condition for over load. (Refrigerant, Pipe length, Blocked, ) CH 62 1. Check the fan is locked. 2. Check the Outdoor temp. is very high.
(3-way) Valve
(3-way) Valve
3-way Valve (Liguid Side) 3-way Valve (Gas Side) Valve cap Open position Closed position Pin To piping connection
To outdoor unit
To outdoor unit
Works Shipping
Service port Closed (with cap) Open (push-pin or with vacuum pump) Closed (with cap) Open (connected manifold gauge) Open (connected manifold gauge) Open (with charging cylinder) Open (connected manifold gauge) Open (connected manifold gauge)
1.
Open Open (counter-clockwise) (push-pin or with vacuum pump) Open (with valve cap) Closed (clockwise) Closed (with cap) Closed (with cap)
Operation
2.
3.
Evacuation (Servicing)
Open
Open
4.
Open
Open
5.
Open
Open
6.
Open
Open
(3-way) Valve
Indoor unit
Indoor unit
Lowhandle (CLOSE)
Procedure 1. Confirm that both the gas side and liquid side valves are set to the open position. - Remove the valve stem caps and confirm that the valve stems are in the raised position. - Be sure to use a hexagonal wrench to operate the valve stems. 2. Operate the unit for 10 to 15 minutes. 3. Stop operation and wait for 3 minutes, then connect the manifold gauge to the service port of the gas side valve. - Connect the hose of the gauge with the push pin to the service port. 4. Air purging of the charge hose. - Open the Low-handle valve on the gauge slightly to air purge from the hose. 5. Set the liquid side valve to the closed position. Be sure to short pressure S/W. otherwise Low pressure S/W detect low pressure skete and stops the compressor. 6. Operate the air conditioner at the cooling cycle and stop it when the gauge indicates 1kg/cm g.
2
7. Immediately set the gas side valve to the closed position. - Do this quickly so that the gauge ends up indicating 1kg/ g. 8. Disconnect the charge set, and mount the liquid side and gas side valve caps and the service port nut. - Use torque wrench to tighten the service port nut to a torque of 1.8kg.m.(4.2kg.m/5.5kg.m) - Be sure to check for gas leakage.
(3-way) Valve
(2) Evacuation
(All amount of refrigerant leaked)
Indoor unit
Indoor unit
Gas side 3-Way valve manifold gauge Vacuum pump Lowhandle (OPEN) Hi- handle (OPEN) Open
Procedure
1. Confirm that both the liguid side valve and gas side valve are set to the opened position. 2. Connect the vaccum pump to the center hose of the manifold gauge. 3. Connect the service port of the gas side valve to the low side of the gauge. 4. Evacuation for approximately one hour. - Confirm that the gauge needle has moved toward-76 cmHg (vacuum of 4 mmHg or less). 5. Close the Low handle of the gauge turn off the vacuum pump, and confirm that the gauge needle does not move(approximately 5 minutes after turning off the vacuum pump). 6. Disconnect the charge hose from the vacuum pump. - Vacuum pump oil. If the vacuum pump oil becomes dirty or depleted,replenish as needed. 7. Mount the valve caps and the service port caps.
(3-way) Valve
Indoor unit
Indoor unit
Procedure
1. Connect the gauge to the charging cylinder. - Connect the charge hose which you disconnected from the vacuum pump to the valve at the bottom of the cylinder. - If you are using a gas cylinder, also use a scale and reverse the cylinder so that the system can be charged with liquid. 2. Purge the air from the charge hose. - Open the valve at the bottom of the cylinder and press the check valve on the charge set to purge the air. (Be careful of the liquid refrigerant). The procedure is the same if using a gas cylinder. 3. Open the low handle on the gauge and charge the system with liquid refrigerant. - If the system can not be charged with the specified amount of refrigerant, it can be charged with a little at a time (approximately 150g each time) while operating the air conditioner in the cooling cycle; however, one time is not sufficient, wait approximately 1 minute and then repeat the procedure(pumping down-pin). 4. Immediately disconnect the charge hose from the gas side valve's service port. This is different from previous procedures. Because you are charging with liquid refrigerant from the gas side, absolutely do not attempt to charge with larger amounts of liquid refrigerant while operating the air conditioner. - Stopping partway will allow the gas to be discharged. - If the system has been charged with liquid refrigerant while operating the air conditioner turn off the air conditioner before disconnecting the hose. 5. Mount the valve stem nuts and the service port nut. - Use torque wrench to tighten the service port nut to a torque of 1.8 kg.m.(4.2kg.m/5.5kg.m.) - Be sure to check for gas leakage.
135314
152313
342800 159830
354210
159901 268712
135311
Exploded View & Replacement Parts List Parts List (SQ, SR chassis)
LOCATION No. DESCRIPTION PART No. AMNH076LQL0 3141A20006A 3531A10127A 3531A20100B 3531A20187M 3551A20050P 4681A20055A 5230A10005A 5231A20032C 5983A10009V 5990A10005A 6323AQ3226T 6323A20004A 6609A10003J 6711A20067J 6871A20194A 6871A20267B 6871A20440A 4280A20004A 4681A20062A 5211AR7066P 5211A20470J 5211A20471D 5251AR2575F 5421A10024A 5901A20007B 3301A10003A 3H01487A AMNH096LQL0 3141A20006A 3531A10127A 3531A20100B 3531A20187M 3551A20050P 4681A20055A 5230A10005A 5231A20032C 5983A10009V 5990A10005A 4995A20361B 6323AQ3226T 6323A20004A 6609A10003J 6711A20067J 6871A20194A 6871A20267B 6871A20440B 4280A20004A 4681A20062A 5211AR7066P 5211A20470J 5211A20471D 5251AR2575F 5421A10024A 5901A20007B 3301A10003A 3H01487A AMNH096LRL0 3141A20005A 3531A10230A 3531A10117C 3531A10208N 3551A20099A 4681A20055A 5230A20014A 5231A20032C 5983A10006T 5990A20007A 4995A20361C 3623AQ3226T 6323A20004A 6609A10003H 6711A20067J 6871A20390A 6871A20267B 6871A20440C 4280A20004A 4681A20048A 5211AR7066L 5211A20388H 5211A20389F 5251AR2575F 5421A20087W 5901A20007A 1H00843A 3H1487A AMNH126LRL0 3141A20005A 3531A10230A 3531A10117C 3531A10208N 3551A20099A 4681A20055A 5230A20014A 5231A20032C 5983A10006T 5990A20007A 4995A20361D 3623AQ3226T 6323A20004A 6609A10003H 6711A20067J 6871A20390A 6871A20267B 6871A20440D 4280A20004A 4681A20048A 5211AR7066L 5211A20388H 5211A20389F 5251AR2575F 5421A20087W 5901A20007A 1H00843A 3H1487A SVC CODE R R R R R R R R R R R R R R R R R R R R R R R R R R R R
131410 CHASSIS ASSEMBLY 135311 GRILLE ASSEMBLY,DISCHARGE(INDOOR) 135314 GRILLE ASSEMBLY,INLET SUB 135316 GRILLE ASSEMBLY,FRONT(INDOOR) 135516 COVER ASSEMBLY,MOTOR 146811 MOTOR ASSEMBLY,STEP 152302 FILTER(MECH),A/C 152313 FILTER ASSEMBLY,DEODORIZER 159830 AIR CLEANER ASSEMBLY 159901 VANE,HORIZONTAL 263230-1 THERMISTOR ASSEMBLY 263230-2 THERMISTOR ASSEMBLY 266090 H.V ASSEMBLY 267110 REMOTE CONTROLLER ASSEMBLY 268712 PWB(PCB) ASSEMBLY,DISPLAY 268715 PWB(PCB) ASSEMBLY,MAIN(AC) 268716 PWB(PCB) ASSEMBLY,MAIN(DC) 342800 BEARING 346810 MOTOR ASSEMBLY,INDOOR 35211B TUBE ASSEMBLY,TUBING 352115 TUBE ASSEMBLY,EVAPORATOR IN 352116 TUBE ASSEMBLY,EVAPORATOR OUT 352150 HOSE ASSEMBLY,DRAIN 354210 EVAPORATOR ASSEMBLY, FIRST 359011 FAN ASSEMBLY,CROSS FLOW 733010 PLATE ASSEMBLY,INSTALL W0CZZ CAPACITOR,DRAWING
135316
267110
135314
152313
342800
352115 352116 35211B 263230-2 352150 146811 346810 135516 263230-1 268715
W0CZZ
Exploded View & Replacement Parts List Parts List (ST chassis)
LOCATION No. DESCRIPTION PART No. AMNH186LTL0 3141A10002A 3531A10116A 3531A20107W 3531A20207E 3551A20099C 4681A20055A 5230A20001A 5983A10006T 5990A20008A 5990A20009A 4995A20361E 6323AQ3226T 6323A20004A 6609A10003L 6711A20067J 6871A20194B 6871A20267B 6871A20440E 4280A20004A 4681A20003D 5211A20514G 5211A30058H 5211A30057D 5251AR2575F 5901A20008A 3301A10002A 5211A30439E 3H01487G AMNH246LTL0 3141A10002A 3531A10116A 3531A20107W 3531A20207E 3551A20099C 4681A20055A 5230A20001A 5983A10006T 5990A20008A 5990A20009A 4995A20361F 6323AQ3226T 6323A20004A 6609A10003L 6711A20067J 6871A20194B 6871A20267B 6871A20440F 4280A20004A 4681A20067A 5211A20514G 5211A30097J 5211A30098G 5251AR2575F 5901A20008A 3301A10002A 5211A30439J 3H01487G SVC CODE R R R R R R R R R R R R R R R R R R R R R R R R R R R R
131410 CHASSIS ASSEMBLY 135311 GRILLE ASSEMBLY,DISCHARGE(INDOOR) 135314 GRILLE ASSEMBLY,INLET SUB 135316 GRILLE ASSEMBLY,FRONT(INDOOR) 135516 COVER ASSEMBLY,MOTOR 146811 MOTOR ASSEMBLY,STEP 152302 FILTER(MECH),A/C 159830 AIR CLEANER ASSEMBLY 159901-1 VANE,HORIZONTAL 159901-2 VANE,HORIZONTAL 249951 CONTROL BOX ASSEMBLY,INDOOR 263230-1 THERMISTOR ASSEMBLY 263230-2 THERMISTOR ASSEMBLY 266090 H.V ASSEMBLY 267110 REMOTE CONTROLLER ASSEMBLY 268712 PWB(PCB) ASSEMBLY,DISPLAY 268715 PWB(PCB) ASSEMBLY,MAIN(AC) 268716 PWB(PCB) ASSEMBLY,MAIN(DC) 342800 BEARING 346810 MOTOR ASSEMBLY,INDOOR 352111* TUBE ASSEMBLY,CONNECTOR 352115 TUBE ASSEMBLY,EVAPORATOR IN 352116 TUBE ASSEMBLY,EVAPORATOR OUT 352150 HOSE ASSEMBLY,DRAIN 359011 FAN ASSEMBLY,CROSS FLOW 733010 PLATE ASSEMBLY,INSTALL 35211B TUBE ASSEMBLY,TUBING W0CZZ CAPACITOR,DRAWING NOTE) 35211* is for pipe fitting to SVC valve.
135515
249951 354210
263230-2
263230-1
135311-2 146811
135500-2
147581
135314 146811-3
268712
135311-3 359012
147581 135500-1
146811-2
Exploded View & Replacement Parts List Parts List (SP1 chassis)
LOCATION No. DESCRIPTION PART No. AMNH096AP*1 AMNC096AP*1 AMNH126AP*1 AMNC126AP*1 3141A20004N 3550A20123A 3550A20124A 3550A20060A 3531A20069G 3531A20069H 3531A20069J 3531A20212K 3531A20212L 3531A20212M 3551A20031B 3531A20213N 3531A20213P 3531A20213Q 4758A20014B 4681A20055C 4681A20055A 5230A20032A 5983A20007F 4994A10046A 6871A20380D 6871A20381D 6609A10003S 6323AQ6226T 6323A20004N 6871A20388A 6711A20073D 3087A30004A 4681A20091A 4960A20016A 5211A20301J 5211A20302J 5211AR7066F 5251AR1222R 5238A20020A 5421A20072A 5900A00003A 3141A20004N 3550A20123A 3550A20124A 3550A20060A 3531A20069G 3531A20069H 3531A20069J 3531A20212K 3531A20212L 3531A20212M 3551A20031B 3531A20213R 3531A20213S 3531A20213T 4758A20014B 4681A20055C 4681A20055A 5230A20032A 5983A20007F 4995A20372N 4994A10046A 6871A20380D 6871A20381G 6609A10003S 6323AQ6226T 6323A20004N 6871A20363D 6711A20073E 3087A30004A 4681A20091A 4960A20016A 5211A20301J 5211A20302J 5211AR7066F 5251AR1222R 5238A20020A 5421A20072A 5900A00003A 3141A20004N 3550A20123A 3550A20124A 3550A20060A 3531A20069G 3531A20069H 3531A20069J 3531A20212K 3531A20212L 3531A20212M 3551A20031B 3531A20213N 3531A20213P 3531A20213Q 4758A20014B 4681A20055C 4681A20055A 5230A20032A 5983A20007F 4995A20372J 4994A10046A 6871A20380D 6871A20381F 6609A10003S 6323AQ6226T 6323A20004N 6871A20388A 6711A20073D 3087A30004A 4681A20091A 4960A20016A 5211A20301J 5211A20302J 5211AR7066F 5251AR1222R 5238A20020A 5421A20072A 5900A00003A 3141A20004N 3550A20123A 3550A20124A 3550A20060A 3531A20069G 3531A20069H 3531A20069J 3531A20212K 3531A20212L 3531A20212M 3551A20031B 3531A20213R 3531A20213S 3531A20213T 4758A20014B 4681A20055C 4681A20055A 5230A20032A 5983A20007F 4995A20372P 4994A10046A 6871A20380D 6871A20381G 6609A10003S 6323AQ6226T 6323A20004N 6871A20363D 6711A20073E 3087A30004A 4681A20091A 4960A20016A 5211A20301J 5211A20302J 5211AR7066F 5251AR1222R 5238A20020A 5421A20072A 5900A00003A SVC CODE R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R
131410 CHASSIS ASSEMBLY 135500-1 COVER 135500-2 COVER 135500-3 COVER 135311-1 GRILLE ASSEMBLY,DISCHARGE(INDOOR) 135311-2 GRILLE ASSEMBLY,DISCHARGE(INDOOR) 135311-3 GRILLE ASSEMBLY,DISCHARGE(INDOOR) 135314 GRILLE ASSEMBLY, INLET M: Matal B: Blue D: Wood 135515 COVER ASSEMBLY,TOP(INDOOR) 135316 GRILLE ASSEMBLY, FRONT(INDOOR) 147581 LOUVER,HORIZONTAL 146811-1 MOTOR ASSEMBLY,STEP 146811-2 MOTOR ASSEMBLY,STEP 152302 FILTER(MECH),A/C 159830 AIR CLEANER ASSEMBLY 249941 CONTROL BOX,INDOOR 268715 PWB(PCB) ASSEMBLY,MAIN(AC) 268716 PWB(PCB) ASSEMBLY,MAIN(DC) 266090 H.V ASSEMBLY 263230-1 THERMISTOR ASSEMBLY 263230-2 THERMISTOR ASSEMBLY 268712 PWB(PCB) ASSEMBLY,DISPLAY 267110 REMOTE CONTROLLER ASSEMBLY 330870 DRAIN PAN ASSEMBLY 346810 MOTOR ASSEMBLY,INDOOR 349600 MOUNT,MOTOR 352116 TUBE ASSEMBLY,EVAPORATOR OUT 352115 TUBE ASSEMBLY,EVAPORATOR IN 35211B TUBE ASSY,TUBING 352150 HOSE ASSEMBLY,DRAIN 352380 AIR GUIDE 354210 EVAPORATOR ASSEMBLY,FIRST 359012 FAN,TURBO M: Matal B: Blue D: Wood
Exploded View & Replacement Parts List Art Cool Deluxe Type(SU, SZ chassis)
146811 135316
152302
668713-1 146811-1
145200
668713-2
135313
135511
263230-2
263230-1
733010
359011
342800
Exploded View & Replacement Parts List Parts List(Art cool Deluxe Type)
LOCATION No. PART No. DESCRIPTION AMNH076DZ*0 3141A20009B 3508A20055B 3508A20056B 3531A20184C 3531A20196J 3531A20196E 3531A20195B 3531A20196F 3531A10214K 3531A10214H 3531A10214J 3531A10214Q 4681A20055A 4681A20055B 5983A10009V 5230A20033A 5990A20022B 4995A20323K 4994A20067A 6302A90003A 6323AQ2226T 6323A20004A 6609A10005B 6711A20073P 6871A10111E 4280A20004A 4681A20103C 5211A202569D 5211A20605B 5211A30596A 5251AR1222R 5421A20149E 5901A20016E 6871A20258B 6871A20259A 3301A10005A 3H01487A W: White M: Metal R: Mirror B: Blue 135316 GRILLE ASSEMBLY, FRONT W: White M: Metal R: Mirror B: Blue 146811 MOTOR ASSEMBLY, STEP (Vane) 146811-1 MOTOR ASSEMBLY, STEP (Door) 159830 AIR CLEANER ASSEMBLY 152302 FILTER (MECH), A/C 159901 VANE HORIZONTAL 249951 CONTROL BOX ASSEMBLY 249941 CONTROL BOX, INDOOR 263020 DIGITRON 263230-1 THERMISTOR ASSEMBLY(Out) 263230-2 THERMISTOR ASSEMBLY(Room, In) 266090 HUB ASSEMBLY 267110 REMOTE CONTROLLER ASSEMBLY 268714 PWB(PCB) ASSEMBLY, MAIN 342800 BEARING 346810 MOTOR ASSEMBLY, INDOOR 352114 TUBE ASSEMBLY DISTRIBUTOR 352118 TUBE ASSEMBLY MANIFOLD 35211B TUBE ASSEMBLY, TUBING 352150 HOSE ASSEMBLY, DRAIN 354212 EVAPORATOR ASSEMBLY, FINAL 359011 FAN ASSEMBLY, CROSS FLOW 668713 PWB ASSEMBLY, SUB 668713 PWB ASSEMBLY, SUB 733010 PLATE W0CZZ CAPACITOR,DRAWING AMNH096DU*0 3141A20007B 3508A20034E 3508A20034F 3531A10137B 3531A20118Z 3531A20118Y 3531A20118X 3531A20118W 3531A21026C 3531A21026B 3531A21026A 3531A21026D 4681A20055A 4681A20055B 5983A10006T 5230A20022A 5990A20015B 4995A20323L 4994A20067A 6302A90003A 6323AQ2226T 6323A20004A 6609A10005A 6711A20073C 6871A10111F 4280A20004A 4681A20048A 5211A202569D 5211A20605B 5211AR7066L 5251AR1222R 5421A20105H 5901A20016A 6871A20258B 6871A20259A 1H00843A 3H01487A AMNH126DU*0 3141A20007B 3508A20034E 3508A20034F 3531A10137B 3531A20118Z 3531A20118Y 3531A20118X 3531A20118W 3531A21026C 3531A21026B 3531A21026A 3531A21026D 4681A20055A 4681A20055B 5983A10006T 5230A20022A 5990A20015B 4995A20232M 4994A20067A 6302A90003A 6323AQ2226T 6323A20004A 6609A10005A 6711A20073C 6871A10111G 4280A20004A 4681A20048A 5211A202569D 5211A20605B 5211AR7066L 5251AR1222R 5421A20105H 5901A20016A 6871A20258B 6871A20259A 1H00843A 3H01487A SVC CODE R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R
131410 CHASSIS ASSEMBLY 135080-1 DECORATION (TOP) 135080-2 DECORATION (BOTTOM) 135311 GRILLE ASSEMBLY, DISCHARGE 135313 GRILLE ASSEMBLY, INLET
Exploded View & Replacement Parts List Duct Type - High Static(BH, BG chassis)
359012 237210
346810
W0CZZ
738290
OW NE RS MA NU AL
152302
268714
738281
INS TA LL MA NU AL
352111
Exploded View & Replacement Parts List Parts List(Duct - High static)
LOCATION No. 152302 237210 249951 DESCRIPTION FILTER (MECH), A/C PANEL ASSEMBLY, UPPER CONTROL BOX ASSEMBLY(INDOOR) PART No. AMNH186BHA0 5230A30001M 3721A20177A 4995A14002A 6323AQ3226G 6323AQ3214E 6323AQ3226V 6711A10008X 6871A10140E 3087A10008B 3660A20017A 3660A20018A 4681A10013C 5211A20514G 5211A20465G 5421A20100A 5901A10026A 5901A10028B 5211A20466K 3828A20403L 3828A20394J 2A00986D AMNH246BHA0 AMNH306BGA0 AMNH366BGA0 5230A30001M 3721A20177A 4995A14002B 6323AQ3226G 6323AQ3214E 6323AQ3226V 6711A10008X 6871A10140F 3087A10008B 3660A20017A 3660A20018A 4681A10013C 5211A20514G 5211A20465G 5421A20100B 5901A10026A 5901A10028B 5211A20466L 3828A20403L 3828A20394J 2A00986D 5230A30001L 3721A20180A 4995A14002C 6323AQ3226G 6323AQ3214E 6323AQ3226V 6711A10008X 6871A10131H 3087A10008A 3660A20019A 3660A20020A 4681A10013J 5211A20514J 5211A20416J 5421A10027A 5901A10026A 5901A10028J 5211A20693D 3828A20403L 3828A20394J 2A00986D 5230A30001L 3721A20180A 4995A14002D 6323AQ3226G 6323AQ3214E 6323AQ3226V 6711A10008X 6871A10131J 3087A10008A 3660A20019A 3660A20020A 4681A10013A 5211A20514J 5211A20416J 5421A10027A 5901A10026A 5901A10028A 5211A20693D 3828A20403L 3828A20394J 2A00986D R R SVC CODE R R R R R R R R R R R R R R R R R R
263230-1 THERMISTOR ASSEMBLY(IN) 263230-2 THERMISTOR ASSEMBLY(ROOM) 263230-3 THERMISTOR ASSEMBLY (OUT) 267110 268714 330860 REMOTE CONTROLLER ASSEMBLY PWB(PCB) ASSEMBLY, MAIN DRAIN PAN ASSEMBLY
336610-1 HOUSING(MECH), WRAPPER 336610-2 HOUSING(MECH), WRAPPER 346810 352118 354210 359012 552111 738282 738290 MOTOR ASSEMBLY, INDOOR TUBE ASSEMBLY, MENIFOLD(INDOOR) EVAPORATOR ASSEMBLY, FIRST FAN ASSEMBLY, BLOWER(Motor) TUBE ASSEMBLY, CAPILLARY MANUAL, INSTALLATION MANUAL, OWNERS 352111* TUBE ASSEMLBY, CONNECTOR
Exploded View & Replacement Parts List Duct Type - Low Static (BT, BT1 chassis)
152302
W0CZZ 359012-1
354210
267110
263230-1
263230-2
263230-3
Exploded View & Replacement Parts List Parts List (Duct Type - Low Static)
LOCATION No. DESCRIPTION PART No. AMNH096BTG0 5230A30001Q 3721A20150B 4995A20338F 6323AQ3226G 6323AQ3214E 6323A20025D 6711A10008U 6871A10131A 3087A10015C 3660A20033A 4681A10022B 5211A10418B 5421A20153B 5901A20030A 5211A10417B 3828A20403E 3828A20395B 3A02157K AMNH126BTG0 5230A30001Q 3721A20150B 4995A20338E 6323AQ3226G 6323AQ3214E 6323A20025D 6711A10008U 6871A10131B 3087A10015C 3660A20033A 4681A10022B 5211A25011B 5421A21002A 5901A20030A 5211A25010A 3828A20403E 3828A20395B 3A02157K AMNH186BTG0 5230A30001P 3721A20150A 4995A20338J 6323AQ3226G 6323AQ3214E 6323A20025D 6711A10008U 6871A10131G 3087A10015B 3660A20033A 4681A10022A 5211A10418C 5421A20153A 5901A20030A 5901A20030B 5211A20514G 5211A10417B 3828A20403E 3828A20395B 3A02157H SVC CODE R R R R R R R R R R R R R R R R R R R R
152302 FILTER(MECH), A/C 237203 PANEL ASSEMBLY, UPPER 249951 CONTROL BOX ASSEMBLY(INDOOR) 263230-1 THERMISTOR ASSEMBLY (IN) 263230-2 THERMISTOR ASSEMBLY (ROOM) 263230-3 THERMISTOR ASSEMBLY (OUT) 267110 REMOTE CONTROLLER ASSEMBLY 268714 PWB(PCB) ASSEMBLY, MAIN 330860 DRAIN PAN ASSEMBLY 336610 HOUSING(MECH), WRAPPER 346810 MOTOR ASSEMBLY, INDOOR 352118 TUBE ASSEMBLY, MENIFOLD(INDOOR) 354210 EVAPORATOR ASSEMBLY, FIRST 359012-1 FAN ASSEMBLY, BLOWER(Single) 359012-2 FAN ASSEMBLY, BLOWER(Single) 352111 TUBE ASSEMBLY, CONNECTOR 552111 TUBE ASSEMBLY, EVAPORATOR IN 738282 MANUAL, INSTALLATION 738290 MANUAL, OWNER'S WOCZZ CAPACITOR, DRAWING
Exploded View & Replacement Parts List Built in Duct type (BP chassis)
137214
267110-2
249951 267110-1
263230-1
158591 346810
352118
359012-1 336610-2
352111 354210
330860
152302
738290
INS TA LL MA NU AL
137202
738282
OW NE RS MA NU AL
Exploded View & Replacement Parts List Parts List(Built in Duct Type-BP chassis)
Location No. 237202 137210 137214 152302 158591 249951 PANLE, FRONT PANEL ASSEMBLY, FRONT (SINGLE) PANEL, UPPER FILTER (MECH), A/C PUMP ASSEMBLY, WATER CONTROL BOX ASSEMBLY(INDOOR) Part No. Description AMNH096BPA0 3720A20260B 3721A20168A 3721A20188A 5230A30001R 5859A20002A 4995A20355C 6323AQ3226G 6323AQ3214E 6323AQ3226V 6711A10008U 6871A10140G 3086A10036A 3660A20017A 3660A20018A 4681A10031A 5211A21171A 5211A21172A 5421A20178E 5901A10049A 5901A10026A 3828A20403J 3828A20394G 2A00986D AMNH126BPA0 3720A20260B 3721A20168A 3721A20188A 5230A30001R 5859A20002A 4995A20355B 6323AQ3226G 6323AQ3214E 6323AQ3226V 6711A10008U 6871A10140H 3086A10036A 3660A20017A 3660A20018A 4681A10031A 5211A21171A 5211A21172A 5421A20178E 5901A10049A 5901A10026A 3828A20403J 3828A20394G 2A00986D R R R SVC CODE R R R R R R R R R R R R R R R R R R
263230-1 THERMISTOR ASSEMBLY (IN) 263230-2 THERMISTOR ASSEMBLY (ROOM) 263230-3 THERMISTOR ASSEMBLY (OUT) 267110 268714 330860 REMOTE CONTROLLER ASSEMBLY PWB(PCB) ASSEMBLY, MAIN DRAIN PAN ASSEMBLY
336610-1 HOUSING(MECH), WRAPPER 336610-2 HOUSING(MECH), WRAPPER 346811 MOTOR ASSEMBLY, INDOOR 352118-1 TUBE ASSEMBLY, MENIFOLD(OUT) 352118-2 TUBE ASSEMBLY, MANIFOLD (IN) 354210 359012 738282 738290 WOCZZ EVAPORATOR ASSEMBLY, FIRST FAN ASSEMBLY, BLOWE MANUAL, INSTALLATION MANUAL, OWNER'S CAPACITOR, DRAWING
267110-1
354212 158591
266012 359011
137211 352116
330860
352115
268712 354210
135802
146811 152302 266090 140570 W0CZZ 249951 152312 159830 135312 738290 738282 268714
OW NE RS MA NU AL
INS TA LL MA NU AL
263230-1
263230-2
263230-3
Exploded View & Replacement Parts List Parts List(Cassette Type - 1 way)
LOCATION No. DESCRIPTION PART No. AMNH096TCC0 3531A10062D 3721A10123F 3580A20005A 6871A10140A 3091A10024A 4681AR2727G 5990A20004A 5859A10001A 5231A10003A 5983A10006A 4995A10114B 6323AQ3226E 6323AQ3226V 6323AQ3214P 6601A20001E 6690A20005C 6711A10008V 6711A20096B 6871A20096B 3087A10005A 5211A20229E 5211A20230E 5421A10011A 5251A20001A 5901AR2441A 4681A20003Y 3828A20394D 3828A20403F 3H00671E 5239A10004A AMNH126TCC0 3531A10062D 3721A10123F 3580A20005A 6871A10140B 3091A10024A 4681AR2727G 5990A20004A 5859A10001A 5231A10003A 5983A10006A 4995A10114A 6323AQ3226E 6323AQ3226V 6323AQ3214P 6601A20001E 6690A20005C 6711A10008V 6711A20096B 6871A20096B 3087A10005A 5211A20229E 5211A20230E 5421A10011A 5251A20001A 5901AR2441A 4681A20003Y 3828A20394D 3828A20403F 3H00671E 5239A10004A R R SVC CODE R R R R R R R R R R R R R R R R R Option R R R R R R R R R
135312 GRILLE ASSEMBLY,INLET 137211 INLET GRILE ASSEMBLY 135802 DOOR LOCK 268714 PWB(PCB) ASSEMBLY,MAIN 139011 CABINET ASSEMBLY,INDOOR 146811 MOTOR ASSEMBLY,STEP 152302 VANE HORIZONTAL 158580 PUMP ASSEMBLY,WATER 152312 FILTER ASSEMBLY,AIR CLEANER 159830 AIR CLEANER ASSEMBLY 249951 CONTROL BOX ASSEMBLY,INDOOR 263230-1 THERMISTOR ASSEMBLY (IN) 263230-2 THERMISTOR ASSEMBLY (OUT) 263230-3 THERMISTOR ASSEMBLY (ROOM) 266012 SWITCH ASSEMBLY,FLOAT 266090 HVB ASSEMBLY 267110-1 REMOTE CONTROLLER ASSEMBLY 267110-2 REMOTE CONTROLLER ASSEMBLY (WIRELESS) 268712 PWB(PCB) ASSEMBLY, DISPLAY 330870 DRAIN PAN ASSEMBLY 352115 TUBE ASSEMBLY,EVAPORATOR IN 352116 TUBE ASSEMBLY, EVAPORATOR OUT 354210 EVAPORATOR ASSEMBLY,FIRST 354212 DRAIN ASSEMBLY,TUBE 359011 FAN ASSEMBLY,CROSS FLOW 346810 MOTOR ASSEMBLY,INDOOR 738290 MANUAL, OWNER'S 738292 MANUAL, INSTALLATION W0CZZ CAPACITOR, DRAWING W1SZ AIR GUIDE ASSEMBLY
Exploded View & Replacement Parts List Cassette Type - 4 way(TE chassis)
266090 249951
263230-3
263230-2
263230-1
268714
159830
354211
352118
35211A
137211 130411
W0CZZ
346811
152312
130911-1
135312-2
135802
Exploded View & Replacement Parts List Parts List(Cassette Type - 4 way - TE 12K, 18K)
LOCATION No. DESCRIPTION PART No. AMNH126TEC0 3041A10013A 3091A10023C 3091A10023D 3721A10105B 3531A10059A 3580A20005A 4681A20055A 5231A10005A 5859A20001M 5983A10002A 4995A14001D 6323AQ3226T 6323AQ3226F 6323A10002A 6601A20001G 6609A20005C 6871A20096J 6871A10158D 6711A20076N 6711A20096B 3087A10002A 4681AC2026E 5211A20241S 5211A20243M 5251A20002A 5421A10006M 5900A10004A 3828A20403F 3828A20394D 3H00660N 4056A20001A AMNH186TEC0 3041A10013A 3091A10023C 3091A10023D 3721A10105B 3531A10059A 3580A20005A 4681A20055A 5231A10005A 5859A20001M 5983A10002A 4995A14001C 6323AQ3226T 6323AQ3226F 6323A10002A 6601A20001G 6609A20005C 6871A20096J 6871A10158C 6711A20076N 6711A20096B 3087A10002A 4681AC2026C 5211A20514G 5211A20241R 5211A20243M 5251A20002A 5421A10006M 5900A10004A 3828A20403F 3828A20394D 3H00660N 4056A20001A R R R SVC CODE R R R R R R R R R R R R R R R R R R R R R R R R R R R R
130411 BASE ASSEMBLY,WELD[INDOOR] 130911-1 CABINET ASSEMBLY,INDOOR 130911-2 CABINET ASSEMBLY,INDOOR 137211 PANEL ASSEMBLY,FRONT(INDOOR) 135312 GRILLE ASSEMBLY,FRONT(INDOOR) 135802 DOOR ROCK 146811 MOTOR ASSEMBLY,STEP 152312 FILTER ASSEMBLY, AIR CLEANER 158591 PUMP ASSEMBLY,WATER 159830 AIR CLEANER ASSEMBLY 249951 CONTROL BOX ASSEMBLY,INDOOR 263230-1 THERMISTOR ASSEMBLY (OUT) 263230-2 THERMISTOR ASSEMBLY (IN) 263230-3 THERMISTOR ASSEMBLY (ROOM) 266012 SWITCH ASSEMBLY,FLOAT 266090 H.V ASSEMBLY 268712 PWB(PCB) ASSEMBLY,DISPLAY 268714 PWB(PCB) ASSEMBLY,MAIN 267110-1 REMOTE CONTROLLER ASSEMBLY 267110-2 REMOTE CONTROLLER ASSEMBLY (WIRELESS) 330870 DRAIN PAN ASSEMBLY 346810 MOTOR ASSEMBLY,INDOOR 352111* TUBE ASSEMBLY, CONNECTOR 352118 TUBE ASSEMBLY,MENIFOLD(INDOOR) 35211A TUBE ASSEMBLY, SUCTION (INDOOR) 352150 DRAIN ASSEMBLY, TUBE 354211 EVAPORATOR ASSEMBLY,BENDING 359011 FAN,TURBO 738282 MANUAL, INSTALLATION 738290 MANUAL,OWNERS W0CZZ CAPACITOR,DRAWING W4056 LOCKER
Exploded View & Replacement Parts List Cassette Type - 4 way(TF chassis)
266090
249951
268714
354211-2 354211-1
159830
158591
266012
330870
130411
359012
152312
130911-2
135314
137211
267110-2
267110-1
130911-1
Exploded View & Replacement Parts List Parts List(Cassette Type - 4 way - TF 24K, 30K)
LOCATION No. DESCRIPTION PART No. AMNH246TFC0 3041A10030B 3091A10051A 3091A10051B 3721A10072E 3531A10211C 4681A20055A 5231A10012A 5859A20001K 5983A10002A 4995A10093K 6323AQ3226Y 6323AQ3226E 6323A10002A 6601A20001H 6609A20005E 6871A20096J 6871A10158B 6711A20076N 6711A20096B 3087A10010B 4681A20051Z 5211A20514G 5211A20251Q 5211A20251K 5211A21137B 5251A20002B 5421A10016G 5421A10016H 5901A10036A 3828A20403F 3828A20394D 3H00660M 4056A20001B AMNH306TFC0 3041A10030B 3091A10051A 3091A10051B 3721A10072E 3531A10211C 4681A20055A 5231A10012A 5859A20001K 5983A10002A 4995A10093N 6323AQ3226Y 6323AQ3226E 6323A10002A 6601A20001H 6609A20005E 6871A20096J 6871A10158R 6711A20076N 6711A20096B 3087A10010B 4681A20051W 5211A20514J 5211A20251Q 5211A20251K 5211A21137B 5251A20002B 5421A10016G 5421A10016H 5901A10036A 3828A20403F 3828A20394D 3H00660M 4056A20001B R R R SVC CODE R R R R R R R R R R R R R R R R R R option R R R R R R R R R R
130411 BASE ASSEMBLY,WELD[INDOOR] 130911-1 CABINET ASSEMBLY,INDOOR 130911-2 CABINET ASSEMBLY,INDOOR 137211 PANEL ASSEMBLY,FRONT(INDOOR) 135314 GRILLE ASSEMBLY,FRONT(INDOOR) 146811 MOTOR ASSEMBLY,STEP 152312 FILTER ASSEMBLY, AIR CLEANER 158591 PUMP ASSEMBLY,WATER 159830 AIR CLEANER ASSEMBLY 249951 CONTROL BOX ASSEMBLY,INDOOR 263230-1 THERMISTOR ASSEMBLY (OUT) 263230-2 THERMISTOR ASSEMBLY (IN) 263230-3 THERMISTOR ASSEMBLY (ROOM) 266012 SWITCH ASSEMBLY,FLOAT 266090 H.V ASSEMBLY 268712 PWB(PCB) ASSEMBLY,DISPLAY 268714 PWB(PCB) ASSEMBLY,MAIN 267110-1 REMOTE CONTROLLER ASSEMBLY 267110-2 REMOTE CONTROLLER ASSEMBLY (WIRELESS) 330870 DRAIN PAN ASSEMBLY 346810 MOTOR ASSEMBLY,INDOOR 352111* TUBE ASSEMBLY, CONNECTOR 352118-1 TUBE ASSEMBLY,MENIFOLD(INDOOR) 352118-2 TUBE ASSEMBLY, MANIFOLD (INDOOR) 552111 TUBE ASSEMBLY, CAPILLARY (INDOOR) 352150 DRAIN ASSEMBLY, TUBE 354211-1 EVAPORATOR ASSEMBLY,BENDING 354211-2 EVAPORATOR ASSEMBLY, BENDING 359012 FAN,TURBO 738282 MANUAL, INSTALLATION 738290 MANUAL,OWNERS W0CZZ CAPACITOR,DRAWING W4056 LOCKER
Exploded View & Replacement Parts List Cassette Type - 4 way(TD chassis)
249951 266090
159830
268714
263230-1 263230-2
130411
263230-3
354211
352118-1
158591
266012
130411
W0CZZ
146811
268712
Exploded View & Replacement Parts List Parts List(Cassette Type - 4 way - TD 36K)
LOCATION No. 130411 130911-1 130911-2 130912-1 130912-2 137211 135314 135802 146811 152312 158591 159830 249951 263230-1 263230-2 263230-3 266012 266090 268712 268714 267110-1 267110-2 330870 346810 352111* 352118-1 352118-2 552111 354211-1 354211-2 359011 738282 738290 W0CZZ W4056 DESCRIPTION BASE ASSEMBLY,WELD[INDOOR] CABINET ASSEMBLY, INDOOR CABINET ASSEMBLY, INDOOR CABINET ASSEMBLY, INDOOR CABINET ASSEMBLY, INDOOR PANEL ASSEMBLY,FRONT(INDOOR) GRILLE ASSEMBLY,FRONT(INDOOR) DOOR ROCK MOTOR ASSEMBLY,STEP FILTER ASSEMBLY, AIR CLEANER PUMP ASSEMBLY,WATER AIR CLEANER ASSEMBLY CONTROL BOX ASSEMBLY,INDOOR THERMISTOR ASSEMBLY (OUT) THERMISTOR ASSEMBLY (IN) THERMISTOR ASSEMBLY (ROOM) SWITCH ASSEMBLY,FLOAT H.V ASSEMBLY PWB(PCB) ASSEMBLY,DISPLAY PWB(PCB) ASSEMBLY,MAIN REMOTE CONTROLLER ASSEMBLY REMOTE CONTROLLER ASSEMBLY (WIRELESS) DRAIN PAN ASSEMBLY MOTOR ASSEMBLY,INDOOR TUBE ASSEMBLY, CONNECTOR TUBE ASSEMBLY,MENIFOLD(INDOOR) TUBE ASSEMBLY, MANIFOLD (INDOOR) TUBE ASSEMBLY, CAPILLARY (INDOOR) EVAPORATOR ASSEMBLY,BENDING EVAPORATOR ASSEMBLY, BENDING FAN,TURBO MANUAL, INSTALLATION MANUAL,OWNERS CAPACITOR,DRAWING LOCKER PART No. AMNH366TDC0 3041A10016A 3091A10030A 3091A10030B 3091A10031A 3091A10031B 3721A10106B 3531A10066A 3580A20005A 4681A20055A 5231A10004A 5859A20001D 5983A10003D 4995A22004L 6323AQ3226V 6323AQ3226A 6323A10002B 6601A20001F 6609A20005D 6871A20096J 6871A10158S 6711A20076N 6711A20096B 3087A10006A 4681A20006J 5211A20154J 5211A20251R 5211A20251B 5211A20316M 5421A10016A 5421A10016B 5900A10003B 3828A20403F 3828A20394D 3H00660M 4056A20001B R R R SVC CODE R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R
Exploded View & Replacement Parts List Convertible Type (VE chassis)
135310
733010 131410
135500 346810 263230-1 354212 35211B 352150 268716 W4810 359011 342800 738282 330780 159830
INS TA LL MA NU AL OW NE RS MA NU AL
131410
268715
266090
Exploded View & Replacement Parts List Parts List(Convertible Type-VE chassis)
PART No. AMNH096VEA0 AMNH096VEL0 AMNH126VEA0 AMNH126VEL0 3721A10092A 4681A20055A 4758A10006A 5230A10009A 4995A20356F 6323A20004T 6323AQ3226V 6600AP2059B 6711A20096A 6871A20390D 6871A20359B 6871A20358E 3078A20001A 3087A10018A 4280A20004A 4681A20131B 5211A21217B 5211A25012B 5211A22007B 5251AR2575Q 5421A30019B 5901A20008E 3301A10002A 3828A20403K 3828A20394H 3H00671A 4810A21019A 3141A10009A 3550A30201A 3531A10248A 3531A10247A 3721A10092A 4681A20055A 4758A10006A 5230A10009A 5983A20007F 4995A20356 6323A20004T 6323AQ3226V 6600AP2059B 6609A10003S 6711A20096A 6871A20390D 6871A20359B 6871A20358 3078A20001A 3087A10018A 4280A20004A 4681A20131B 5211A21217B 5211A25012B 5211A22007B 5251AR2575Q 5421A30019B 5901A20008E 3301A10002A 3828A20403K 3828A20394H 3H00671A 4810A21019A 3141A10009A 3550A30201A 3531A10248A 3531A10247A 3721A10092A 4681A20055A 4758A10006A 5230A10009A 4995A20356E 6323A20004T 6323AQ3226V 6600AP2059B 6711A20096A 6871A20390D 6871A20359B 6871A20358F 3078A20001A 3087A10018A 4280A20004A 4681A20131A 5211A21217B 5211A25012B 5211A22007B 5251AR2575Q 5421A30019B 5901A20008E 3301A10002A 3828A20403K 3828A20394H 3H00671A 4810A21019A 3141A10009A 3550A30201A 3531A10248A 3531A10247A 3721A10092A 4681A20055A 4758A10006A 5230A10009A 5983A20007F 4995A20356 6323A20004T 6323AQ3226V 6600AP2059B 6609A10003S 6711A20096A 6871A20390D 6871A20359B 6871A20358 3078A20001A 3087A10018A 4280A20004A 4681A20131A 5211A21217B 5211A25012B 5211A22007B 5251AR2575Q 5421A30019B 5901A20008E 3301A10002A 3828A20403K 3828A20394H 3H00671A 4810A21019A 3141A10009A 3550A30201A 3531A10248A 3531A10247A R R R R R R R
DESCRIPTION PANEL ASSEMBLY,FRONT(INDOOR) MOTOR ASSEMBLY,STEP LOUVER,HORIZONTAL FILTER(MECH),A/C AIR CLEANER ASSEMBLY CONTROL BOX ASSEMBLY,INDOOR
SVC CORD R R R R R R R R R R R R R R R R R R R R R R R R R
263230-1 THERMISTOR ASSEMBLY (IN, ROOM) 263230-2 THERMISTOR ASSEMBLY (OUT) 266000 266090 267110 268712 268715 268716 330780 330870 342800 346810 35211B 352115 352116 352150 354211 359011 733010 738282 738290 W0CZZ W4810 131410 135500 135310 135313 SWITCH,PUSH H.V ASSEMBLY REMOTE CONTROLLER ASSEMBLY PWB(PCB) ASSEMBLY,DISPLAY PWB(PCB) ASSEMBLY,MAIN(AC) PWB(PCB) ASSEMBLY,MAIN(DC) CUT OFF DRAIN PAN ASSEMBLY BEARING MOTOR ASSEMBLY,INDOOR TUBE ASSEMBLY,TUBING TUBE ASSEMBLY, EVAPORATOR IN TUBE ASSEMBLY EVAPORATOR OUT HOSE ASSEMBLY,DRAIN EVAPORATOR ASSEMBLY,FIRST FAN ASSEMBLY,CROSS FLOW PLATE ASSEMBLY,INSTALL MANUAL INSTALLATION MANUAL OWNER'S CAPACITOR,DRAWING BRACKET CHASSIS ASSEMBLY COVER GRILL ASSEMBLY, DIFFUSER(INDOOR) GRILL ASSEMBLY, INLET
NOTE) *Please ensure GCSC since these parts may be changed depending upon the buyer's request. (GCSC WEBSITE http://biz.LGservice.com)
135310 738290
352111
738282
INS TA LL MA NU AL
OW NE RS MA NU AL
146811
159911
346810 166000
159912
352150
267110
137211
135314
135303
Exploded View & Replacement Parts List Parts List(Convertible Type-VB chassis)
Part No. Location No. 130911 135303 135310 135314 137211 146811 152302 159911 159912 166000 235450 237900 249951 263230-1 263230-2 267110 268711 268712 330870 342800 346810 35211A 352111* 352115 352150 354210 359010 738290 738282 W0CZZ Description CABINET ASSEMBLY GRILLE, INLET GRILLE ASSEMBLY, DIFFUSER (INDOOR) GRILLE ASSEMBLY, INLET SUB PANEL ASSEMBLY, FRONT (INDOOR) MOTOR ASSEMBLY, STEP FILTER(MECH), A/C VANE ASSEMBLY, HORIZONTAL(UPPER) VANE ASSEMBLY, HORIZONTAL(LOWER) SWITCH, PUSH DISPLAY ASSEMBLY (MECH) WINDOW, DISPLAY CONTROL BOX ASSEMBLY, INDOOR THERMISTOR ASSEMBLY (ROOM, IN) THERMISTOR ASSEMBLY (OUT) REMOTE CONTROLLER ASSEMBLY PWB(PCB) ASSEMBLY, MAIN PWB(PCB) ASSEMBLY, DISPLAY DRAIN PAN ASSEMBLY BEARING MOTOR ASSEMBLY, INDOOR TUBE ASSEMBLY, SUCTION INDOOR TUBE ASSEMBLY, CONNECTOR TUBE ASSEMBLY, EVAPORATOR - IN HOSE ASSEMBLY, DRAIN EVAPORATOR ASSEMBLY, FIRST FAN ASSEMBLY, CROSS FLOW MANUAL, OWNERS MANUAL, INSTALLATION CAPACITOR, DRAWING AMNH186VBA0 3091AP2533A 5230AP1236A 3531A10272C 5237AP2817B 3720AP2767P 4681A20055A 5230AP7093A 5991AP2867B 5991AP7334C 6600AP2059B 3545AP7224B 3790AP7080A 4995A10107B 6323A20004Y 6323AQ3226Y 6711A20096A 3871A10159B 6871AQ3263A 3087AP7233A 3H02821B 4681AP2306M 5211AP2813G 5211A20514G 5211AP2810Q 5251AP2460B 5421AP2812B 5901AR2351E 3828A20394H 3828A200403K 3H00671A AMNH246VBA0 3091AP2533A 5230AP1236A 3531A10272C 5237AP2817B 3720AP2767P 4681A20055A 5230AP7093A 5991AP2867B 5991AP7334C 6600AP2059B 3545AP7224B 3790AP7080A 4995A10107C 6323A20004Y 6323AQ3226Y 6711A20096A 3871A10159A 6871AQ3263A 3087AP7233A 3H02821B 4681AP2306N 5211AP2813H 5211A20514G 5211AP2810R 5251AP2460B 5421AP2812A 5901AR2351E 3828A20394H 3828A200403K 3H00671A R SVC CODE R R R R R R R R R R R R R R R R R R R R R R R R R R R R
A2UW146FA0
554031
437212
Outdoor Unit
435512 552112
552113-1
435301
263230-2 561410
552113-2
OW NE RS MA NU AL
552203-1 552203-2
INS TA LL MA NU AL
437211
552203-1 552203-2
738282
435512 552112
552113-1
A2UW186FA0, A3UW186FA0
558511
546810
561411
SE RV ICE MA NU AL
552113-2
OW NE RS MA NU AL
552203-1 552203-2
INS TA LL MA NU AL
437211
552203-1 552203-2
738282
Exploded View & Replacement Parts List Outdoor Unit Parts List (Single compressor inverter)
LOCATION No. DESCRIPTION PART No. A2UW146FA0 A2UW186FA0 1A00201D 3A02284M 6323A20020F 6323A20020G 3041A20022Q 3530A20007J 3A01919B 3H03266K 3721A20005P 3H03307L 4681A20028S 5211A24019A 5211A24018A 5220A20001K 2A02479R 6141A20018K 6141A20018L 5211A20493Q 5403A10013J 5416A90008A 5851A30004A 5901A10032A 6141AR3509L 6140A90001F 4995A10101H 5874A90003A 6871A10117K 6871A20484A 3828A20097W 3828A20403A 3828A20394A 2A00986D 3720AP0003F 498110019B 5220A90010A 6323A20020F 6323A20020G 3041A20022Q 3530A20007J 3A01919B 3H03266L 3721A20004L 1A00207B 3H03307L 4681A20028S 5211A30298A 5211A30297Z 5211A20927A 5220A20001K 2A00468J 6877A20050A 6877A20050B 5211A20493H 5403A20072N 5416A90015A 5851A30004A 5901A10032A 6141AR3509L 6140A90001K 3A02524F 4995A10101A 5874A90003A 6871A10117B 6871A20484A 3828A20097W 3828A20403A 3828A20394A 2A00986D A3UW186FA0 1A00201D 3A02284M 6323A20020F 6323A20020G 3041A20022Q 3530A20007J 3A01919B 3H03266L 3721A20004L 1A00207B 3H03307L 4681A20028S 5211A30298A 5211A30297Z 5211A21155C 5220A20001K 2A00468J 6877A20050A 6877A20050B 6877A20050K 5211A20493R 5403A20072N 5416A90015A 5851A30004A 5901A10032A 6141AR3509L 6140A90001K 3A02524F 4995A10101J 5874A90003A 6871A10117L 6871A20484A 3828A20097W 3828A20403A 3828A20394A 2A00986D R R R R R SVC CODE R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R OPTION R
137213-1 PANEL ASSEMBLY, SIDE 137213-2 PANEL ASSEMBLY, SIDE 263230-1 THERMISTOR ASSEMBLY (ROOM, OUT) 263230-3 THERMISTOR ASSEMBLY (DISCHARGE, SUCTION) 430411 BASE ASSEMBLY, WELD[OUTDOOR] 435301 GRILLE, DISCHARGE 435511 COVER ASSEMBLY, CONTROL(OUTDOOR) 435512 COVER ASSEMBLY, TOP(OUTDOOR) 437210 PANEL ASSY, FRONT SUB 435300 GRILLE, REAR 447910 BARRIER ASSEMBLY, OUTDOOR 546810 MOTOR ASSEMBLY, OUTDOOR 552112 TUBE ASSEMBLY, CONDENSER IN 552113-1 TUBE ASSEMBLY, CONDENSER OUT 552113-2 TUBE ASSEMBLY, COND OUT (SUPPORTER) 552203-1 VALVE, SERVICE (9.52) 552203-2 VALVE, SERVICE (6.35) 552204-1 COIL ASSEMBLY, SOLENOID (A) 552204-2 COIL ASSEMBLY, SOLENOID (B) 552204-3 COIL ASSEMBLY, SOLENOID (C) 552116 TUBE ASSEMBLY, REVERSING 554031 CONDENSER ASSEMBLY, BENT 554160 COMPRESSOR 558511 DRIER ASSEMBLY 559010 FAN ASSEMBLY, PROPELLER 561410 COIL ASSEMBLY, REVERSING VALVE 561411 COIL ASSEMBLY, EXPANSION 566000 SWITCH, PRESSURE (LOW PRESSURE) 649950 CONTROL BOX ASSEMBLY, OUTDOOR 658740 REACTOR 668711 PWB(PCB) ASSEMBLY, MAIN(OUTDOOR) 668713 PWB(PCB) ASSEMBLY, SUB (CENTRAL CONTROL) 738281 MANUAL, SERVICE 738282 MANUAL, INSTALLATION 738290 MANUAL, OWNERS W0CZZ CAPACITOR, DRAWING 437212 PANEL ASSEMBY, REAR W49810 SUPPORT ASSEMBLY 552200 VALVE, EXPANSION BODY
435512
A3UW246FA0, A4UW246FA0
566000
546810
263230-1
263230-2 668711 447910 561411-1 561411-2 561411 561411-3 561411-4 561410 554160-1 554160-2
SE RV ICE MA NU AL
263230-3 435511
435301
552113-1 552113-2
INS TA LL MA NU AL
OW NE RS MA NU AL
437210
552113
738282
Exploded View & Replacement Parts List Parts List (A3UW246FA0, A4UW246FA0 - TPS Inverter)
Location No. 137213-1 137213-2 263230-1 263230-2 263230-3 352113 430410 435300 435301 435511 435512 437210 447910 546810 548490 552111 552113 552115 552116 552203-1 552203-2 552204 554031 554160 554161 558511 559010 561410-1 561410-2 561410-3 561410 561411-1 561411-2 561411-3 561411-4 566000 649950 658740 668711 668713 738281 738282 738290 552201 W0CZZ-1 W0CZZ-2 Part No. Description PANEL ASSEMBLY, SIDE PANEL ASSEMBLY, SIDE THERMISTOR ASSEMBY (INV DISCHARGE, SUCTION) THERMISTOR ASSEMBLY (CONST DISCHARGE) THERMISTOR, ASSEMBLY (ROOM, COND OUT) TUBE, ASSEMBLY, DISCHARGE BASE ASSEMBLY, WELD GRILLE, REAR GRILLE, DISCHARGE COVER ASSEMBLY, CONTROL (OUTDOOR) COVER ASSEMBLY, TOP PANEL ASSEMBLY, FRONT SUB BARRIER ASSEMBLY, OUTDOOR MOTOR ASSEMBLY, OUTDOOR ACCUMULATOR ASSEMBLY TUBE ASSEMBLY, CAPILLARY TUBE ASSEMBLY, CONDENSER OUT TUBE ASSEMBLY, MANIFOLD TUBE ASSEMBLY, REVERSING VALVE, SERVICE (9.52) VALVE, SERVICE (6.35) VALVE, SOLENOID (BODY) CONDENSER ASSEMBLY, BENT COMPRESSOR (INVERTER) COMPRESSOR (CONSTANT) DRIER, ASSEMBLY FAN ASSEMBLY, PROPELLER COIL ASSEMBLY, REVERSING VALVE COIL ASSEMBLY, SOLENOID COIL ASSEMBLY, SOLENOID VALVE, EXPANSION BODY COIL ASSEMBLY EXPANSION (A) COIL ASSEMBLY EXPANSION (B) COIL ASSEMBLY EXPANSION (C) COIL ASSEMBLY EXPANSION (D) SWITCH, PRESSURE CONTROL BOX ASSEMBLY, OUTDOOR REACTOR PWB(PCB) ASSEMBLY, MAIN(OUTDOOR) PWB(PCB) ASSEMBLY, SUB (CENTRAL CONTROL) MANUAL SERVICE MANUAL INSTALLATION MANUAL OWNER'S VALVE, CHECK CAPACITOR, DRAWING (FAN) CAPACITOR, DRAWING (COMP) A3UW246FA0 1A00202F 3A02284R 6323A20030G 6323A20001J 6323A20020F 5211A23013A 3041AP2741H 1A00208H 3530A20007J 3A01919B 3551A30113C 1A00197C 4791A30004M 4681A20028Y 4849A22003A 5211A22009A 5211A21155B 5211A20895A 5211A20896A 5220A20001K 2A02479J 5220A90002C 5403A20070B 5416A90015A 5416A90016A 5851A30004A 5901A10032A 6871A20052D 6877A20052E 6877A20052F 6140A90001K 6877A20050C 6877A20050D 6877A20050E 3A02524F 4995A10101B 5874A90003A 6871A10117C 6871A20484A 3828A20097W 3828A20403A 3828A20394A 5220A30004A 2A00986D 2H00841F A4UW246FA0 1A00202F 3A02284T 6323A20030G 6323A20001J 6323A20020F 5211A23013A 3041AP2741H 1A00208H 3530A20007J 3A01919B 3551A30113C 1A00197C 4791A30004M 4681A20028Y 4849A22003A 5211A22009A 5211A21155A 5211A20895A 5211A20896A 5220A20001K 2A02479J 5220A90002C 5403A20070B 5416A90015A 5416A90016A 5851A30004A 5901A10032A 6871A20052D 6877A20052E 6877A20052F 6140A90001K 6877A20050C 6877A20050D 6877A20050E 6877A20050L 3A02524F 4995A10101K 5874A90003A 6871A10117M 6871A20484A 3828A20097W 3828A20403A 3828A20394A 5220A30004A 2A00986D 2H00841F SVC CODE R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R
566000
552116
OW
A4UW306FA0
NE
RS
MA
NU AL
738290
558511
SE
RV
ICE
MA N
UA
738281
INS
TA LL
MA
NU
AL
738282 546810-2
668711
435301
W0CZZ-2 552113
658740 430410
Exploded View & Replacement Parts List Parts List (A4UW306FA0 - TPS Inverter)
Part No. Location No. 135301 137213-1 137213-2 263230-1 263230-2 263230-3 352113 430410 435300 435511 435512 437211 447910 546810-1 546810-2 548490 552111 552113 552115 552116 552201 552203-1 552203-2 552204 554031 554160 554161 558511 559010 561410 561410-1 561410-2 561410-3 561411-1 561411-2 561411-3 561411-4 566000 649950 658740 668711 668713 738281 738282 738290 W0CZZ-1 W0CZZ-2 Description GRILLE,DISCHARGE PANEL ASSEMBLY,SIDE PANEL ASSEMBLY,SIDE THERMISTOR ASSEMBLY (ROOM, COND, OUT) THERMISTOR ASSEMBLY (DISCHARGE, SUCTION) THERMISTOR ASSEMBLY (DISCHARGE, CONST) TUBE ASSEMBLY, DISCHARGE SINGLE BASE ASSEMBLY, OUTDOOR GRILLE,REAR COVER ASSEMBLY,CONTROL(OUTDOOR) COVER ASSEMBLY,TOP(OUTDOOR) PANEL ASSEMBLY,FRONT(OUTDOOR) BARRIER ASSEMBLY,OUTDOOR MOTOR ASSEMBLY,OUTDOOR MOTOR ASSEMBLY, OUTDOOR ACCUMULATOR ASSEMBLY(MECH) TUBE ASSEMBLY, CAPILLARY TUBE ASSEMBLY, CONDENSER OUT TUBE ASSEMBLY, MANIFOLD TUBE ASSEMBLY,REVERSING VALVE, CHECK VALVE,SERVICE(9, 52) VALVE,SERVICE (6, 35) VALVE, SOLENOID (BODY) CONDENSER ASSEMBLY,BENT COMPRESSOR (INVERTER) COMPRESSOR (CONSTANT) DRIER ASSEMBLY FAN ASSEMBLY,PROPELLER VALVE, EXPANSION (BODY) COIL ASSEMBLY,REVERSING VALVE COIL ASSEMBLY SOLENOID (P/ICE) COIL ASSEMBLY SOLENOID (OIL/S) COIL ASSEMBLY,EXPANSION (A) COIL ASSEMBLY,EXPANSION (B) COIL ASSEMBLY,EXPANSION (C) COIL ASSEMBLY,EXPANSION (D) SWITCH, PRESSURE (LOW) CONTROL BOX ASSEMBLY,OUTDOOR REACTOR PWB(PCB) ASSEMBLY,MAIN(OUTDOOR) PWB(PCB) ASSEMBLY, SUB (CENTRAL CONTROL) MANUAL,SERVICE MANUAL,INSTALLATION MANUAL,OWNERS CAPACITOR,DRAWING (COMP) CAPACITOR,DRAWING (FAN) A4UW306FA0 3530A20006B 3721A10110A 3721A10111A 6323A20020H 6323A20020J 6323A20001K 35211A23013A 3041AP2741H 3530A10176B 3A01919B 3551A30113C 3721A10109A 4791A10019A 4681AR1392Y 4681AR1392Z 4849A22003A 5211A22010A 5211A21155A 5211A20895B 5211A20896A 5220A30004A 5220A20001K 2H02479J 5220A90002C 5403A20168B 5416A90015A 5416A90021A 5851A30004A 5901A10033A 6140A90001K 6877A20052A 6877A20052B 6877A20052C 6877A20050F 6877A20050G 6877A20050H 6877A20050J 3A02524F 4995A10101C 5874A90003A 6871A10117D 6871A20484A 3828A20097W 3828A20403A 3828A20394A 2A00986X 2H00660P SVC CODE R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R Option R R R R
435512 658740
A6UW406FA0
558511
668713
263230-1
263230-2
263230-3
437210
435301
738290
OW NE RS MA NU AL
435511
554031-2 552115-2
552113-2
738281
SE RV ICE MA NU AL
237204
738282
INS TA LL MA NU AL
552115-1
Exploded View & Replacement Parts List Parts List (A6UW406FA0 - TPS Inverter)
Part No. Location No. 137213 263230-1 263230-2 263230-3 35211A 352112 430410 435301 435511 435512 437210 437212 447910 546810-1 546810-2 548490 552102 552112 552113 552115-1 552115-2 552116 55211A 55211G 552201 552203-1 552203-2 552204 554031-1 554031-2 554160-1 554160-2 558511 559010 561410 561410-1 561410-2 561411 566000 649950 658740 668711 668713 669200 738281 738282 738290 W0CZZ-1 W0CZZ-2 Description PANEL, SIDE THERMISTOR ASSEMBLY (ROOM, COND OUT) THERMISTOR ASSEMBLY (DISCHARGE SUCTION) THERMISTOR ASSEMBLY (DISCHARGE CONSTANT) TUBE ASSEMBLY, SUCTION (INDOOR) TUBE ASSEMBLY, COUPLING BASE ASSEMBLY, WELD GRILLE, DISCHARGE COVER ASSEMBLY, CONTROL COVER ASSEMBLY, TOP PANEL ASSEMBLY, FRONT SUB PANEL ASSEMBLY, REAR BARRIER ASSEMBLY, OUTDOOR MOTOR ASSEMBLY, OUTDOOR MOTOR ASSEMBLY, OUTDOOR ACCUMULATOR ASSEMBLY TUBE ASSEMBLY, EXPANSION TUBE ASSEMBLY, CAPILLARY TUBE ASSEMBLY, CONDENSER OUT TUBE ASSEMBL, MANIFOLD(OUTDOOR) 19.05 TUBE ASSEMBL, MANIFOLD(OUTDOOR) 9.52 TUBE ASSEMBLY, REVERSING TUBE ASSEMBLY, SUCTION INDOOR TUBE ASSEMBLY, EXPANSION VALVE, CHECK VALVE, SERVICE (19, 05) VALVE, SERVICE (9, 52) VALVE, SOLENOID (BODY) CONDENSER ASSEMBLY, BENT CONDENSER ASSEMBLY, BENT COMPRESSOR SET (INVERTER) COMPRESSOR SET (CONSTANT) DRIER ASSEMBLY FAN ASSEMBLY, PROPELLER VALVE, EXPANSION (BODY) COIL ASSEMBLY, REVERSING VALVE COIL ASSEMBLY, SOLENOID (BY-PASS) COIL ASSEMBLY, EXPANSION SWITCH, PRESSURE CONTROL BOX ASSEMBLY, OUTDOOR REACTOR PWB(PCB) ASSEMBLY, MAIN(OUTDOOR) PWB(PCB) ASSEMBLY, SUB (CENTRAL CONTROL) RELAY MANUAL, SERVICE MANUAL INSTALLATION MANUAL OWNER'S CAPACITOR, DRAWING (FAN) CAPACITOR, DRAWING (COMP) A6UW406FA0 3720AP1215B 6323A20020H 6323A20020J 6323A20020K 5211A21187A 5211A10433A 3041A20047K 3530AP1225D 3A01293X 3550AP1213B 3720AP1212B 3720AP1202C 4791A20012E 4681A20028J 4681A20028Q 4849A10009A 5211A22013A 5211A10430A 5211A23015A 5211A22018A 5211A22018B 5211A21188A 5211A21187A 5211A10434A 5220A30004A 2A00499L 5220A20001E 5220A90002C 5403A20166J 5403A20166K 5416A90015A 5416A90017A 5851A20002A 5901A10032A 6140A90001H 6141AR3509A 6141A2013G 6141A30003M 3A02524F 4995A10118A 5874A90003A 6871A10117E 6871A20484A 6920AP3400A 3828A20097W 3828A20403A 3828A20394A 2A00986D 2A00986A SVC CODE R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R OPTION R R R R R
435312 349490
137213 559010
549610 546810
447910-1 330870
552113-1 552113-2
552112-1
352114-4 561410
552203-2
346811
430410 137213
554160-2
554160-1
554160-2