Sei sulla pagina 1di 11

Thermodynamics An Engineering Approach 8th

Edition Cengel Test Bank


Download full test bank + solution manual at :
https://testbankpack.com/

Multiple-Choice Test Problems


Chapter 5: Mass and Energy Analysis of Control Volumes
Çengel/Boles - Thermodynamics: An Engineering Approach, 8th Edition
(Numerical values for solutions can be obtained by copying the EES solutions given and pasting them on
a blank EES screen, and pressing the Solve command. Similar problems and their solutions can be
obtained easily by modifying numerical values.)

Chap5-1 Steam Nozzle m_dot


Steam is accelerated by a nozzle steadily from a low velocity to a velocity of 220 m/s at a rate of 1.2 kg/s.
If the steam at the nozzle exit is at 300C and 2 MPa, the exit area of the nozzle is
2 2 2 2 2
(a) 6.8 cm (b) 7.2 cm (c) 3.8 cm (d) 54.6 cm (e) 22.8 cm
2
Answer (a) 6.8 cm

Solution Solved by EES Software. Solutions can be verified by copying-and-pasting the following lines
on a blank EES screen.

Vel_1=0 "m/s"
Vel_2=220 "m/s"
m=1.2 "kg/s"
T2=300 "C"
P2=2000 "kPa"
"The rate form of energy balance is E_dot_in - E_dot_out = DELTAE_dot_cv"
v2=VOLUME(Steam_IAPWS,T=T2,P=P2)
m=(1/v2)*A*Vel_2 "A in m^2"

“Some Wrong Solutions with Common Mistakes:”


R=0.4615 "kJ/kg.K"
P2*v2ideal=R*(T2+273)
m=(1/v2ideal)*W1_A*Vel_2 "assuming ideal gas"
P2*v3ideal=R*T2
m=(1/v3ideal)*W2_A*Vel_2 "assuming ideal gas and using C for temperature"
m=W3_A*Vel_2 "not using specific volume"

Chap5-2 R134a Diffuser m_dot


Refrigerant 134a enters a diffuser steadily at 0.5 MPa, 50C, and 120 m/s at a rate of 1.2 kg/s. The inlet
area of the diffuser is
2 2 2 2 2
(a) 0.81 cm (b) 4.8 cm (c) 26 cm (d) 5.3 cm (e) 100 cm
2
Answer (b) 4.8 cm
Solution Solved by EES Software. Solutions can be verified by copying-and-pasting the following lines
on a blank EES screen.

Vel_1=120 "m/s"
m=1.2 "kg/s"
T1=50 "C"
P1=500 "kPa"
"The rate form of energy balance is E_dot_in - E_dot_out = DELTAE_dot_cv"
v1=VOLUME(R134a,T=T1,P=P1)
m=(1/v1)*A*Vel_1 "A in m^2"

“Some Wrong Solutions with Common Mistakes:”


R=0.08149 "kJ/kg.K"
P1*v1ideal=R*(T1+273)
m=(1/v1ideal)*W1_A*Vel_1 "assuming ideal gas"
P1*v2ideal=R*T1
m=(1/v2ideal)*W2_A*Vel_1 "assuming ideal gas and using C"
m=W3_A*Vel_1 "not using specific volume"

Chap5-3 Adiabatic Air-Water HX T_cold_out


An adiabatic heat exchanger is used to heat cold water at 8C entering at a rate of 3 kg/s by hot air at 150C
entering also at rate of 3 kg/s. If the exit temperature of hot air is 30C, the exit temperature of cold water
is (use constant specific heats at room temperature)

(a) 150C (b) 30C (c) 36.9C (d) 28.6C (e) 128C

Answer (c) 36.9C

Solution Solved by EES Software. Solutions can be verified by copying-and-pasting the following lines
on a blank EES screen.

C_w=4.18 "kJ/kg-C"
Cp_air=1.005 "kJ/kg-C"
Tw1=8 "C"
m_dot_w=3 "kg/s"
Tair1=150 "C"
Tair2=30 "C"
m_dot_air=3 "kg/s"
"The rate form of energy balance for a steady-flow system is E_dot_in = E_dot_out"
m_dot_air*Cp_air*(Tair1-Tair2)=m_dot_w*C_w*(Tw2-Tw1)

“Some Wrong Solutions with Common Mistakes:”


(Tair1-Tair2)=(W1_Tw2-Tw1) "Equating temperature changes of fluids"
Cv_air=0.718 "kJ/kg.K"
m_dot_air*Cv_air*(Tair1-Tair2)=m_dot_w*C_w*(W2_Tw2-Tw1) "Using Cv for air"
W3_Tw2=Tair1 "Setting inlet temperature of hot fluid = exit temperature of cold fluid"
W4_Tw2=Tair2 "Setting exit temperature of hot fluid = exit temperature of cold fluid"

Chap5-4 Air-Water HX w/Heat Loss T_cold


A heat exchanger is used to heat cold water at 8C entering at a rate of 1.2 kg/s by hot air at 90C entering
at rate of 2.5 kg/s. The heat exchanger is not insulated, and is loosing heat at a rate of 28 kJ/s. If the exit
temperature of hot air is 20C, the exit temperature of cold water is (use constant specific heats at room
temperature)

(a) 43.1C (b) 48.6C (c) 78.0C (d) 37.5C (e) 27.5C

Answer (d) 37.5C

Solution Solved by EES Software. Solutions can be verified by copying-and-pasting the following lines
on a blank EES screen.

C_w=4.18 "kJ/kg-C"
Cp_air=1.005 "kJ/kg-C"
Tw1=8 "C"
m_dot_w=1.2 "kg/s"
Tair1=90 "C"
Tair2=20 "C"
m_dot_air=2.5 "kg/s"
Q_loss=28 "kJ/s"
"The rate form of energy balance for a steady-flow system is E_dot_in = E_dot_out"
m_dot_air*Cp_air*(Tair1-Tair2)=m_dot_w*C_w*(Tw2-Tw1)+Q_loss

“Some Wrong Solutions with Common Mistakes:”


m_dot_air*Cp_air*(Tair1-Tair2)=m_dot_w*C_w*(W1_Tw2-Tw1) "Not considering Q_loss"
m_dot_air*Cp_air*(Tair1-Tair2)=m_dot_w*C_w*(W2_Tw2-Tw1)-Q_loss "Taking heat loss as heat
gain"
(Tair1-Tair2)=(W3_Tw2-Tw1) "Equating temperature changes of fluids"
Cv_air=0.718 "kJ/kg.K"
m_dot_air*Cv_air*(Tair1-Tair2)=m_dot_w*C_w*(W4_Tw2-Tw1)+Q_loss "Using Cv for air"

Chap5-5 Adiabatic HX of Water T_cold_out


An adiabatic heat exchanger is used to heat cold water at 12C entering at a rate of 4 kg/s by hot water
entering at 95C at rate of 2.5 kg/s. If the exit temperature of hot water is 50C, the exit temperature of cold
water is

(a) 90C (b) 50C (c) 95C (d) 57C (e) 40C

Answer (e) 40C

Solution Solved by EES Software. Solutions can be verified by copying-and-pasting the following lines
on a blank EES screen.

C_w=4.18 "kJ/kg-C"
Tcold_1=12 "C"
m_dot_cold=4 "kg/s"
Thot_1=95 "C"
Thot_2=50 "C"
m_dot_hot=2.5 "kg/s"
Q_loss=0 "kJ/s"
"The rate form of energy balance for a steady-flow system is E_dot_in = E_dot_out"
m_dot_hot*C_w*(Thot_1-Thot_2)=m_dot_cold*C_w*(Tcold_2-Tcold_1)+Q_loss

“Some Wrong Solutions with Common Mistakes:”


Thot_1-Thot_2=W1_Tcold_2-Tcold_1 "Equating temperature changes of fluids"
W2_Tcold_2=90 "Taking exit temp of cold fluid=inlet temp of hot fluid"
Chap5-6 Adiabatic Mixing of Water T_mix
In a water heating system, cold water at 5C flowing at a rate of 5 kg/s is mixed adiabatically with hot water
at 80C flowing at a rate of 2 kg/s. The exit temperature of the mixture is

(a) 26.4C (b) 42.5C (c) 40.0C (d) 64.3C (e) 55.2C

Answer (a) 26.4C

Solution Solved by EES Software. Solutions can be verified by copying-and-pasting the following lines
on a blank EES screen.

C_w=4.18 "kJ/kg-C"
Tcold_1=5 "C"
m_dot_cold=5 "kg/min"
Thot_1=80 "C"
m_dot_hot=2 "kg/min"
"The rate form of energy balance for a steady-flow system is E_dot_in = E_dot_out"
m_dot_hot*C_w*Thot_1+m_dot_cold*C_w*Tcold_1=(m_dot_hot+m_dot_cold)*C_w*Tmix

“Some Wrong Solutions with Common Mistakes:”


W1_Tmix=(Tcold_1+Thot_1)/2 "Taking the average temperature of inlet fluids"

Chap5-7 Adiabatic Mixing of Air T_mix


In a heating system, cold outdoor air at 10C flowing at a rate of 6 kg/min is mixed adiabatically with hot air
at 50C flowing at a rate of 1.5 kg/min. Assuming constant specific heats at room temperature, the exit
temperature of the mixture is

(a) 30C (b) 18C (c) 45C (d) 22C (e) 38C

Answer (b) 18C

Solution Solved by EES Software. Solutions can be verified by copying-and-pasting the following lines
on a blank EES screen.

C_air=1.005 "kJ/kg-C"
Tcold_1=10 "C"
m_dot_cold=6 "kg/min"
Thot_1=50 "C"
m_dot_hot=1.5 "kg/min"
"The rate form of energy balance for a steady-flow system is E_dot_in = E_dot_out"
m_dot_hot*C_air*Thot_1+m_dot_cold*C_air*Tcold_1=(m_dot_hot+m_dot_cold)*C_air*Tmix

“Some Wrong Solutions with Common Mistakes:”


W1_Tmix=(Tcold_1+Thot_1)/2 "Taking the average temperature of inlet fluids"

Chap5-8 Gas Turbine wHeat Loss


Hot combustion gases (assumed to have the properties of air at room temperature) enter a gas turbine at
0.8 MPa and 1500 K at a rate of 2.1 kg/s, and exit at 0.1 MPa and 800 K. If heat is lost from the turbine to
the surroundings at a rate of 150 kJ/s, the power output of the gas turbine is

(a) 1477 kW (b) 1677 kW (c) 1327 kW (d) 1124 kW (e) 872 kW
Answer (c) 1327 kW

Solution Solved by EES Software. Solutions can be verified by copying-and-pasting the following lines
on a blank EES screen.

Cp_air=1.005 "kJ/kg-C"
P1=800 "kPa"
T1=1500 "K"
T2=800 "K"
m_dot=2.1 "kg/s"
Q_dot_loss=150 "kJ/s"
"The rate form of energy balance for a steady-flow system is E_dot_in = E_dot_out"
W_dot_out+Q_dot_loss=m_dot*Cp_air*(T1-T2)
"Alternative: Variable specific heats - using EES data"
W_dot_outvariable+Q_dot_loss=m_dot*(ENTHALPY(Air,T=T1)-ENTHALPY(Air,T=T2))

“Some Wrong Solutions with Common Mistakes:”


W1_Wout=m_dot*Cp_air*(T1-T2) "Disregarding heat loss"
W2_Wout-Q_dot_loss=m_dot*Cp_air*(T1-T2) "Assuming heat gain instead of loss"

Chap5-9 Adiabatic R134a Turbine


Refrigerant-134a expands in an adiabatic turbine from 1 MPa and 120C to 0.10 MPa and 50C at a rate
of 0.8 kg/s. The power output of the turbine is

(a) 72.5 kW (b) 58.0 kW (c) 43.5 kW (d) 46.4 kW (e) 54.4 kW

Answer (d) 46.4 kW

Solution Solved by EES Software. Solutions can be verified by copying-and-pasting the following lines
on a blank EES screen.

P1=1000 "kPa"
T1=120 "C"
P2=100 "kPa"
T2=50 "C"
m_dot=0.8 "kg/s"
Q_dot_loss=0 "kJ/s"
h1=ENTHALPY(R134a,T=T1,P=P1)
h2=ENTHALPY(R134a,T=T2,P=P2)
"The rate form of energy balance for a steady-flow system is E_dot_in = E_dot_out"
-W_dot_out-Q_dot_loss=m_dot*(h2-h1)

"Checking using properties from tables:"


h11=332.47
h22=295.45
-Wtable-Q_dot_loss=m_dot*(h22-h11)

“Some Wrong Solutions with Common Mistakes:”


-W1_Wout-Q_dot_loss=(h2-h1)/m_dot "Dividing by mass flow rate instead of multiplying"
-W2_Wout-Q_dot_loss=h2-h1 "Not considering mass flow rate"
u1=INTENERGY(R134a,T=T1,P=P1)
u2=INTENERGY(R134a,T=T2,P=P2)
-W3_Wout-Q_dot_loss=m_dot*(u2-u1) "Using internal energy instead of enthalpy"
-W4_Wout-Q_dot_loss=u2-u1 "Using internal energy and ignoring mass flow rate"
Chap5-10 Adiabatic Steam Turbine
Steam expands in an adiabatic turbine from 4 MPa and 500C to 0.5 MPa and 250C at a rate of 1740 kg/h.
The power output of the turbine is

(a) 1004 kW (b) 485 kW (c) 182 kW (d) 377 kW (e) 235 kW

Answer (e) 235 kW

Solution Solved by EES Software. Solutions can be verified by copying-and-pasting the following lines
on a blank EES screen.

P1=4000 "kPa"
T1=500 "C"
P2=500 "kPa"
T2=250 "C"
m_dot=1740/3600 "kg/s"
Q_dot_loss=0 "kJ/s"
h1=ENTHALPY(Steam_IAPWS,T=T1,P=P1)
h2=ENTHALPY(Steam_IAPWS,T=T2,P=P2)
"The rate form of energy balance for a steady-flow system is E_dot_in = E_dot_out"
-W_dot_out-Q_dot_loss=m_dot*(h2-h1)

“Some Wrong Solutions with Common Mistakes:”


-W1_Wout-Q_dot_loss=(h2-h1)/m_dot "Dividing by mass flow rate instead of multiplying"
-W2_Wout-Q_dot_loss=h2-h1 "Not considering mass flow rate"
u1=INTENERGY(Steam_IAPWS,T=T1,P=P1)
u2=INTENERGY(Steam_IAPWS,T=T2,P=P2)
-W3_Wout-Q_dot_loss=m_dot*(u2-u1) "Using internal energy instead of enthalpy"
-W4_Wout-Q_dot_loss=u2-u1 "Using internal energy and ignoring mass flow rate"

Chap5-11 Steam Turbine wHeat Loss


Steam expands in a turbine from 6 MPa and 500C to 0.2 MPa and 150C at a rate of 1.2 kg/s. Heat is lost
from the turbine at a rate of 34 kJ/s during the process. The power output of the turbine is

(a) 750 kW (b) 784 kW (c) 818 kW (d) 573 kW (e) 641 kW

Answer (a) 750 kW

Solution Solved by EES Software. Solutions can be verified by copying-and-pasting the following lines
on a blank EES screen.

T1=500 "C"
P1=6000 "kPa"
T2=150 "C"
P2=200 "kPa"
m_dot=1.2 "kg/s"
Q_dot_loss=34 "kJ/s"
h1=ENTHALPY(Steam_IAPWS,T=T1,P=P1)
h2=ENTHALPY(Steam_IAPWS,T=T2,P=P2)
"The rate form of energy balance for a steady-flow system is E_dot_in = E_dot_out"
W_dot_out+Q_dot_loss=m_dot*(h1-h2)

“Some Wrong Solutions with Common Mistakes:”


W1_Wout=m_dot*(h1-h2) "Disregarding heat loss"
W2_Wout-Q_dot_loss=m_dot*(h1-h2) "Assuming heat gain instead of loss"
u1=INTENERGY(Steam_IAPWS,T=T1,P=P1)
u2=INTENERGY(Steam_IAPWS,T=T2,P=P2)
W3_Wout+Q_dot_loss=m_dot*(u1-u2) "Using internal energy instead of enthalpy"
W4_Wout-Q_dot_loss=m_dot*(u1-u2) "Using internal energy and wrong direction for heat"

Chap5-12 Adiabatic Steam Compressor


Steam is compressed by an adiabatic compressor from 0.1 MPa and 100C to 1.0 MPa and 400C at a rate
of 0.85 kg/s. The power input to the compressor is

(a) 692 kW (b) 500 kW (c) 383 kW (d) 451 kW (e) 588 kW

Answer (b) 500 kW

Solution Solved by EES Software. Solutions can be verified by copying-and-pasting the following lines
on a blank EES screen.

P1=100 "kPa"
T1=100 "C"
P2=1000 "kPa"
T2=400 "C"
m_dot=0.85 "kg/s"
Q_dot_loss=0 "kJ/s"
h1=ENTHALPY(Steam_IAPWS,T=T1,P=P1)
h2=ENTHALPY(Steam_IAPWS,T=T2,P=P2)
"The rate form of energy balance for a steady-flow system is E_dot_in = E_dot_out"
W_dot_in-Q_dot_loss=m_dot*(h2-h1)

“Some Wrong Solutions with Common Mistakes:”


W1_Win-Q_dot_loss=(h2-h1)/m_dot "Dividing by mass flow rate instead of multiplying"
W2_Win-Q_dot_loss=h2-h1 "Not considering mass flow rate"
u1=INTENERGY(Steam_IAPWS,T=T1,P=P1)
u2=INTENERGY(Steam_IAPWS,T=T2,P=P2)
W3_Win-Q_dot_loss=m_dot*(u2-u1) "Using internal energy instead of enthalpy"
W4_Win-Q_dot_loss=u2-u1 "Using internal energy and ignoring mass flow rate"

Chap5-13 Adiabatic R134a Compressor


Refrigerant-134a is compressed by an adiabatic compressor from the saturated vapor state at 0.12 MPa to
1.2 MPa and 70C at a rate of 0.108 kg/s. The power input to the compressor is

(a) 587 kW (b) 63.4 kW (c) 6.85 kW (d) 6.42 kW (e) 59.4 kW

Answer (c) 6.85 kW

Solution Solved by EES Software. Solutions can be verified by copying-and-pasting the following lines
on a blank EES screen.

P1=100 "kPa"
x1=1
P2=1400 "kPa"
T2=60 "C"
m_dot=0.15 "kg/s"
Q_dot_loss=1.80 "kJ/s"
h1=ENTHALPY(R134a,x=x1,P=P1)
h2=ENTHALPY(R134a,T=T2,P=P2)
"The rate form of energy balance for a steady-flow system is E_dot_in = E_dot_out"
W_dot_in-Q_dot_loss=m_dot*(h2-h1)

"Checking using properties from tables:"


h11=233.86
h22=298.96
Wtable-Q_dot_loss=m_dot*(h22-h11)

“Some Wrong Solutions with Common Mistakes:”


W1_Win+Q_dot_loss=m_dot*(h2-h1) "Wrong direction for heat transfer"
W2_Win =m_dot*(h2-h1) "Not considering heat loss"
u1=INTENERGY(R134a,x=x1,P=P1)
u2=INTENERGY(R134a,T=T2,P=P2)
W3_Win-Q_dot_loss=m_dot*(u2-u1) "Using internal energy instead of enthalpy"
W4_Win+Q_dot_loss=u2-u1 "Using internal energy and wrong direction for heat transfer"

Chap5-14 R134a Compressor wCooling


Refrigerant-134a is compressed steadily from the saturated vapor state at 0.10 MPa to 1.4 MPa and 60C
at a rate of 0.15 kg/s. The refrigerant is cooled at a rate of 1.80 kJ/s during compression. The power input
to the compressor is

(a) 5.74 kW (b) 7.54 kW (c) 9.08 kW (d) 9.34 kW (e) 46.7 kW

Answer (d) 9.34 kW

Solution Solved by EES Software. Solutions can be verified by copying-and-pasting the following lines
on a blank EES screen.

P1=100 "kPa"
x1=1
P2=1400 "kPa"
T2=60 "C"
m_dot=0.15 "kg/s"
Q_dot_loss=1.80 "kJ/s"
h1=ENTHALPY(R134a,x=x1,P=P1)
h2=ENTHALPY(R134a,T=T2,P=P2)
"The rate form of energy balance for a steady-flow system is E_dot_in = E_dot_out"
W_dot_in-Q_dot_loss=m_dot*(h2-h1)

"Checking using properties from tables:"


h11=233.86
h22=298.96
Wtable-Q_dot_loss=m_dot*(h22-h11)

“Some Wrong Solutions with Common Mistakes:”


W1_Win+Q_dot_loss=m_dot*(h2-h1) "Wrong direction for heat transfer"
W2_Win =m_dot*(h2-h1) "Not considering heat loss"
u1=INTENERGY(R134a,x=x1,P=P1)
u2=INTENERGY(R134a,T=T2,P=P2)
W3_Win-Q_dot_loss=m_dot*(u2-u1) "Using internal energy instead of enthalpy"
W4_Win+Q_dot_loss=u2-u1 "Using internal energy and wrong direction for heat transfer"
Chap5-15 R134a Condenser Q_out
Saturated refrigerant 134a vapor at 40C is condensed as it flows through a tube at a rate of 0.2 kg/s. The
condensate leaves the tube as saturated liquid at 40C. The rate of heat transfer from the tube is

(a) 21.0 kJ/s (b) 53.4 kJ/s (c) 162 kJ/s (d) 74.4 kJ/s (e) 32.4 kJ/s

Answer (e) 32.4 kJ/s

Solution Solved by EES Software. Solutions can be verified by copying-and-pasting the following lines
on a blank EES screen.

T1=40 "C"
m_dot=0.2 "kg/s"
h_f=ENTHALPY(R134a,T=T1,x=0)
h_g=ENTHALPY(R134a,T=T1,x=1)
h_fg=h_g-h_f
Q_dot=m_dot*h_fg

“Some Wrong Solutions with Common Mistakes:”


W1_Q=m_dot*h_f "Using hf"
W2_Q=m_dot*h_g "Using hg"
W3_Q=h_fg "not using mass flow rate"
W4_Q=m_dot*(h_f+h_g) "Adding hf and hg"

Chap5-16 Electric Heating of Helium


Helium gas is to be heated steadily by a 3-kW electric resistance heater as it flows through an insulated
duct. If the helium enters at 50C at a rate of 0.08 kg/s, the exit temperature of helium will be

(a) 57.2°C (b) 50.6°C (c) 62.0°C (d) 71.9°C (e) 112.0°C

Answer (a) 57.2°C

Solution Solved by EES Software. Solutions can be verified by copying-and-pasting the following lines
on a blank EES screen.

Cp=5.1926 "kJ/kg-C"
T1=50 "C"
m_dot=0.08 "kg/s"
W_dot_e=3 "kJ/s"
W_dot_e=m_dot*Cp*(T2-T1)

“Some Wrong Solutions with Common Mistakes:”


Cv=3.1156 "kJ/kg.K"
W_dot_e=Cp*(W1_T2-T1) "Not using mass flow rate"
W_dot_e=m_dot*Cv*(W2_T2-T1) "Using Cv"
W_dot_e=m_dot*Cp*W3_T2 "Ignoring T1"

Chap5-17 Throttling of Air


Air at 300 K and 200 kPa is throttled by a valve to a pressure of 100 kPa. If the valve is adiabatic and the
change in kinetic energy is negligible, the temperature of air after throttling will be
(a) 150 K (b) 200 K (c) 300 K (d) 450 K (e) 600 K

Answer (c) 300 K


Solution Solved by EES Software. Solutions can be verified by copying-and-pasting the following lines
on a blank EES screen.

"The temperature of an ideal gas remains constant during throttling, and thus"
T1=300 "K"
P1=200 "kPa"
P2=100 "kPa"
T2=T1 "K"

“Some Wrong Solutions with Common Mistakes:”


W1_T2=T1*P1/P2 "Assuming v=constant"
W2_T2=T1*P2/P1 "Assuming v=constant and pressures backwards"

Chap5-18 Throttling of SatLiquid Water x2


Saturated liquid water at 1.0 MPa is throttled adiabatically to a pressure of 0.4 MPa. If the change in kinetic
energy is negligible, the percentage of water that evaporates during this throttling process will be

(a) 0.0% (b) 3.8% (c) 24.8% (d) 7.4% (e) 100%

Answer (d) 7.4%

Solution Solved by EES Software. Solutions can be verified by copying-and-pasting the following lines
on a blank EES screen.

P1=1000 "kPa"
x1=0
P2=400 "kPa"
"Quality represents the percentage of water that evaporates:"
h1=ENTHALPY(Steam_IAPWS,x=x1,P=P1)
x2=QUALITY(Steam_IAPWS,h=h1,P=P2)

“Some Wrong Solutions with Common Mistakes:”


v1=VOLUME(Steam_IAPWS,x=x1,P=P1)
W1_x2=QUALITY(Steam_IAPWS,v=v1,P=P2) "Assuming the volume to remain constant"
u1=INTENERGY(Steam_IAPWS,x=x1,P=P1)
W2_v2=VOLUME(Steam_IAPWS,u=u1,P=P2) "Assuming u=constant"

Chap5-19 Throttling of R134a T2


Saturated Refrigerant-134a liquid at 0.8 MPa is throttled to a pressure of 0.12 MPa. The temperature of the
refrigerant after throttling is
(a) -14.6°C (b) -5.6°C (c) 0°C (d) 31.3°C (e) -22.4°C

Answer (e) -22.4°C

Solution Solved by EES Software. Solutions can be verified by copying-and-pasting the following lines
on a blank EES screen.

P1=800 "kPa"
x1=0
P2=120 "kPa"
"Quality represents the percentage of water that evaporates:"
h1=ENTHALPY(R134a,x=x1,P=P1)
T2=TEMPERATURE(R134a,h=h1,P=P2)

“Some Wrong Solutions with Common Mistakes:”


W1_T2=TEMPERATURE(R134a,x=0,P=P1) "Taking the temperature to be the saturation
temperature at P1"

Chap5-20 Throttling of Steam v2


Steam at 4 MPa and 400C is throttled adiabatically to a pressure of 1 MPa. If the change in kinetic energy
is negligible, the specific volume of the steam after throttling will be
3 3 3 3 3
(a) 0.2952 m /kg (b) 0.2327 m /kg (c) 0.3749 m /kg (d) 0.5165 m /kg (e) 0.3066 m /kg
3
Answer (a) 0.2952 m /kg

Solution Solved by EES Software. Solutions can be verified by copying-and-pasting the following lines
on a blank EES screen.

P1=4000 "kPa"
T1=400 "C"
P2=1000 "kPa"
h1=ENTHALPY(Steam_IAPWS,T=T1,P=P1)
v2=VOLUME(Steam_IAPWS,h=h1,P=P2)

“Some Wrong Solutions with Common Mistakes:”


W1_v2=VOLUME(Steam_IAPWS,T=T1,P=P2) "Assuming the volume to remain constant"
u1=INTENERGY(Steam,T=T1,P=P1)
W2_v2=VOLUME(Steam_IAPWS,u=u1,P=P2) "Assuming u=constant"
W3_v2=VOLUME(Steam_IAPWS,T=T1,P=P2) "Assuming T=constant"

Potrebbero piacerti anche