28-March-2011
Problem description: During installation of TMA in case of BTS3012, numbers of TMA alarms were observed. Example TMA current high alarm, TMA current low alarm & TMA shortcircuit alarm. This result
2011-09-06 HUAWEI Confidential Page1, Total5
in TMAs not working in particular site or sector. Also if everything was OK, it was observed that TMA alarms reappeared after 20days of more duration.
Cause Analysis: After visiting few sites it is observed that , TMA alarms are because of wrong positions or faulty components or wrong configuration . TMA alarms reappearing are because of feeder line problems or some components gone faulty while working.
Handling process: 1. Ensure that DATU card is inserted properly inside BTS3012.
2.
Ensure that BSC & BTS end configurations are correct & all 6 ports of DATU are enabled.
2011-09-06
HUAWEI Confidential
Page2, Total5
3. If you observe any of the following TMA alarm use steps 4 onwards for troubleshooting.
4. While installation, three types of TMA alarms observed frequently. Use following table to solve.
Alarm A) 10258 TMA current high alarm + VSWR alarm B) 10262 TMA Shortcircuit alarm
Reason 1) TMA hardware faulty 1) BiasT & surge arrestor positions wrong 2) BiasT faulty 3) SMA cable short-circuited 4) TMA operating frequency not correct 1)RF connector not proper at feeder end 2) SMA cables damaged 3) feeder open at antenna or TMA end 4) High Feeder VSWR
2011-09-06
HUAWEI Confidential
Page3, Total5
arrestor-BiasT-RFcable-TMA-Antenna
2011-09-06
HUAWEI Confidential
Page4, Total5
Alarm
Analysis
Action
VSWR level2Feeder is swapped with working sector, TheAfter replacing alarm along withproblem shifted to other sector, Bias-TTMA, alarm TMA high currentbypassed but alarm still observed, anddisappeared alarm suspecting problem in feeder line/TMA may be faulty. TMA short-circuitThe battery inside shelter was burnt &After replacing alarm observedbecause of high temperature, SMA cablesSMA cables alarm on 2nd tributary found stick to each other. cleared. VSWR level2Water drops observed in Bias-T & feeder alarm along withconnector, Bias-T replaced but alarm TMA high currentreappeared. After feeder swap concluded that alarm there is problem in feeder/ TMA VSWR level2Feeder observed hanging on tower near TMA alarm along with TMA low current alarm
Alarm reappeared after many days Alarm reappeared after many days Alarm reappeared after 6 days
Conclusion:
If there is problem in TMA or feeder line or if there is any wrong connection of surge arrester or bias-T, it will reflect corresponding TMA alarm on BTS/DATU. This means DATU is not faulty & will reflect alarm related to TMA operating. After correcting fault & clearing alarm, TMA will operate normally.