Sei sulla pagina 1di 4

Questionnaire for gas / HFO liquid fuel Based Power Plant

Information Required for Selection / Sizing/ Design of Power Plant A SITE CONDITIONS 1) Altitude (m above Sea Level) :2) Maximum Ambient Temperature. ( C) :- 45 Degree Cent 3) Relative Humidity at Maximum Ambient ( % ) :4) Wet Bulb Temperature of the Area ( C) :5) Environment (Dusty / Clean) :- Clean 6) Presence of any Hazardous or Chemically :-Active Gases In Surrounding Air 7) Soil Condition at site (normal, marshy :- Normal black cotton etc.) 8) Soil bearing capacity :(< 15 tons/m2 or > 15 tons/m2) 9) Water table at site :-

B POWER REQUIREMENT ( As discussed personally present conditions given ) 1) Maximum Demand (kVA) :-Max Demand reached in Last 4 Years - KVA 2) Minimum continuous process loads (kVA / kW) :3) Grid Voltage and Frequency :- 22 KV ( +/- 10 % ) Variation Percentage :- 50 Hz ( +/- 4% ) 4) Whether Independent Auxiliary Power Supply?:- Yes ( 415 V) available 5) Proposed Power Plant capacity (MW) :- Option 1 - for 50 % Load; Option 2 - for 100 % Load

C STEAM REQUIREMENT (IF ANY) If system can provide the steam it can be used for preheating in our existing system. At present we are using thermal oil based heating system

1) For process Steam (Quantity T/hr., :-pressure) 2) For air-conditioning / chillers etc. :-(quantity T/hr., pressure) 3) For fuel heating only :- For Fuel Heating 4) Existing Boiler(s) details :-

D FUEL 1) Type of fuel to be used :- HFO/ HPS / LSHS / FO / LDO / HSD / NG / BIOGAS (Please provide specifications of fuel, in case of Gas Annexure IV shall be filled also) 2) Approximate price of fuel at site (Rs. / kL) :- Rs. 18000 per KL 3) Design Viscosity of Fuel handling System :-(380 or 500 cST at 50 C) 4) Fuel Handling and Storage Facility at site :- Tank of 65 KL capacity (If any for existing Generating Sets) INFORMATION REQUIRED TO DETERMINE OPERATING PHILOSOPHY A POWER PLANT OPERATION :- Continuous (Continuous / Base Load / Standby / Emergency / Peaking) B PARALLEL OPERATION 1) With grid ( Yes / No ) :- Yes 2) Between proposed DG Sets (Yes / No ) :- Yes 3) With existing DG / TG Sets (Yes / No) :- No Details of existing DG /TG sets (if parallel operations required.) i) Supplier / Model / Name plate details :- We have Old 180 KVA DG set which are used at present for Emergency Lighting etc incase of Power shutdown / Breakdown ii) Rating (kVA / kW) :- 180 KVA * 2 Nos iii) Make / Model / Type of Governor :- Kirloskar iv) Type of Excitation / AVR :-

v) Synchronization Facility :-

C SPECIAL REQUIREMENTS 1) Motor Starting Duty (If any) :- We have rolling mills. The (If yes, please provide details wherever possible) maximum size of the motor is 750 HP DC having a full load current of 1006 Amp. When it starts from standstill it takes @ 1600 Amp + current. 2) Furnace application :- We have 3 No. Foil Annealing Furnace. 1350 KW 3) Non-linear Thyristor Loads, if any :- Thyristor drives - Yes 4) Any other non-standard loads, if any :5) Voltage requirement (3.3 / 6.6 / 11 kV) :- 3.3 KV ( my existing feeder is 22 KV incoming and Step down to 3.3 KV ) 6) Water Availability :-(Sufficient - Cooling Towers, Scarce - Radiators) If Yes in case of C1, C2 and / or C3 above Annexures - I. II and III (Page 5 of 8, 6 of 8 & 7 of 8) shall be filled also. In case of Non-linear loads please provide harmonics analysis report also. INFORMATION ABOUT THE CLIENT (PURCHASER / OWNER COMPANY) 1) Contact Person & Designation :Office Address / Telephone / Fax # -- Electrical Industries Ltd 2) Name / address / Tel. of Consultant (if any) :- NA 3) Annual Turnover of the Company :-Plant @ 168 Cr 4) Main Product and installed capacity :-Aluminum. foil & Packaging Products 5) Location of the Site :- Kalwa - Thane 6) Availability for proposed Power plant at site :7) Contact Person at Site :- As Above Address / Telephone / Fax # 8) Whether power requirement is for :- Existing Plant existing plant /expansion project / new project

9) Duty structure :-(EPCG / EOU / Project Import / IPP) 10) Project Implementation Schedule :- FY 07-08 (Power Out - month / year) 11) Mode of Financing the Project :12) Type of Offer Required :- Budget + Firm (Feasibility Study / Indicative / Budget / Firm) 13) Cost of existing Power (a) From Grid including Maximum. Demand Charges :- @ Rs. 4.4 per Unit (b) Generated from other source :(DG / TG etc.) Additional Information :Max Demand Charges Rs. 350 per KVA Rate Rs. 2.85 per Unit Other Charges Rs. 1.0 Per Unit Avg. Unit Charge Rs. 4.4 per Unit Avg. Consumption 1250000 units per month

Potrebbero piacerti anche