Sei sulla pagina 1di 4
WATO EX-30 Anesthesia Machines Technical specifications Physical cifications Dimensions and Weight Height width: Depth: Weight: Top Shelf Weight limit: Length: wid Worksurface Height: width: Dept DINRall Side of machine: 1375mm ‘710mm (without breathing circuit) {880 mm (with breathing circuit) 620mm <<120kg (including trolley base, without vaporizerand cylinder) 30k 550mm 265mm 820mm ‘500m 310mm 320mm Drawer--internal dimensions Height: width: Depth: Bagarm Height: Length: Connection: asters Screen Display type: Display size: Resolution: Brightness 240mm asomm 278mm 1030mm 320mm 's022mmoD, 15mm iD 125mm ‘two offourcasters Coloractive mattix FT 8.4in diagonal ‘800x600 Adjustable Multi-display selectable : Standard Display Parameters: Allsettingsand Display Graphics: im parameters(Breath rate, \VEratio, tidal volume, minute volume, PEEP, Pmean Ppeak, Pplat and O, concentration,) Waves of Pressure-Time,Flow-Time, Volume- Time, Wave of CO,Optionall: Timer: Time of operation willbe displayed on thescreen Ventilator Specifications StandbyMode: Machine isones ventilation andalarm parameterscan be set Mode ofVentilation Volume-Controllad Ventilation (VCV) with tidal vlume compensation Pressure Mode Ventilation (P-mode) Manual Ventilator Parameter Ranges Tidal volumeranye: 40-1500 (veV nade) Incremental settings: 20~100mi(inerements of 5 ml) 100-300 milincrements of 10 ml) 300 ~1500 mi (increments of 25 mi). Pressure inspired) range: 5 ~60cmH,0 Increments of 1 emHO Pressure limit) range:t0~100cmH,0 Increments of emHO Raterange: 4-100bpm Increments of 1 bpm (VCV,P-mode) 4-60bpm Increments of tbpm(SiMV) Inspiratory/Expiratory ati (KE) ange#:1=1:8 Increments of0.5 (VCV, P-mode) Inspiratory pause time-OFF,5~60% of inspiratory time Increments of 5%. Tiiggerwindow: —5-90% Increments of536(SIMV) Flow trigger: 0.5~15L/min Increments of 0.5L/min (SINV) Pressuretigger: —-20=-1emH,0 Increments of 5% (SIMV) WATO™EX-30 Anesthesia Machines Positive End Expiratory Pressure (PEEP) Type: Integrated, electronically controlled Range: OFF,4~30.cmH.O increments of Tem, Ventilator Performance Pressure rangeat inlet.0.28-0.6MPa Peakgasflow: —_100L/min+Fresh gas, Flowvalverange: 1t0100L/min Ventilator Accuracy Delivery/ monitoring accuracy Volumedelivery: <75ml,15ml = 75 mi, #20mlor #109, whichever i limits £40 cmH,0,0r 10% whichever islarger PEEPdelivery: —_£2.0cmH,0,0r 10%, whicheverislarger Volumemonitoring: <75ml+15ml 75 ml, <1500 mL, £20ml or +108, whichever Isterger >1500mLunspecitied Pressure monitoring: *3.0cmH,0,or 8%, whicheverislarger Alarm Settings Tidal volume(explratoryiigh:5~1600 ml Low:0~1595 mi Minute volumeexpiratory)#High: 0.2 ~100L, Low:0~991, Inspired oxygen: High: 20-100% Low: 18~98% Lowalrway pressure: 0~98 emH,0 Mighpressure:-2>100emH,0 ‘Apnea alarm: 205 Ventilator Monitaring ‘Minute volume range(explratory):0~100L/min igelexpiratory):0~1500 ml Inspired oxygen(Fi0,):18~ 10036 Tidal volumes Peakpressure: —— -20-120emH,0 Meanpressure: -20~120¢mH,0 Plateaupressure: — -20-120cmH,0 ‘Sweep speed: 125016.25mm/s Positive End Expiratory Pressure (PEEP):0~30emH,O Trend chart Continuous trend information together with time discrete events are stored and shown by lines forthe latest 24 hours with 5 seconds ‘resolution for TVE, peak, MV, Pplat, PEEP, Pmean,fateand optional FIO, £1€0,. New trend chart willbe recorded when restart the machine TrendTable Continuoustrend information together withtime discrete eventsare stored and shown by table forthe latest 24 hours forTVe, Ppeak, MV, pat, PEEP, Pmean,Rate and optional FiO, EICO, Resolution: 305,1 min, 2mineo 4min optional ‘New trend form willbe vecorded when restart the machine Vaporizer ‘Type: Penlon Sigma Delta or Sigma Alpha vaporizer, optionsinclude Desflurane Isoflurane, Enflurane, Sevoflurane, Halothane vaporizer Position ofvaporizer: one ordual-positions Instllationmode: _ selectatec* with interlock Electrical Specifications CurrentLeakage 100-240V< 500 uA Power and Battery Backup Power input 100-240 Vac, 50/60 Hz, 3.0~2.64 Battery backup: 90 minor piece battery (powered by new fully-charged batteries with 25°C ambient temperaturc)150 minfor2 piece battery (powered by new fullycharged batteries vith 25 ambient temperature) Bottery type: build-in Lion battery 11.1 VDC, 4400mAh Numberofbatteries: 10r2 pieces Timetoshutdown: 5~15min powered by new ully-charged batteriesafterthefirst low-power alarm) CChargetime: [Approximately hours inunning status or standby mode) Power cord: 5m Pneumatic Specifications ‘Switching Ausiliary Common Gas Outlet{ACGO) Connector: |s022mm 0D and 15 mmi0 The outlet locates atthe|nsplratory limb Gas Supply Pipelineinputrange: 0.28-0.6MPs Pipelineconnections: NIST, DISS CGlinderinput: PISS, Maximum 2 cylinders, optional Primary regulator nominal output: 207KPa ‘Mechanical control flow meters yrange: «wo low tubes with the ranges of ~1L/Min and 10L/min NOrange: ‘wo flow tubes with the ranges of 0~1L/Min and 10min Arrange: ‘two flow tubes with the ranges of 0~1L/Min and 10min Accuracy: <£10% of indication ‘Auxiliary, Flowmeter (Optional) Range: 0-18Umin Indicator: flow tube Hypoxic Guard System Wee: Mechanical Range: Providesa nominal minimum 25% concentration of oxygeninO, /N,O mixture 0, Controls Method: NO shutoff with loss of O, pressure Supply failure alarm: <200 kPa 0, Flush: 25-75 Limin Breathing Circuit Specification Operational Modes: closed and semi-closed circuit system Volume of C0, canister: about 1500 mt Water Trap: ‘6mL, easy to be disassembled Portand Connectors: Inspiration/ expiration connector:22 mm OD and 15 mmi0 conical connector Manualbag port: 22mm ODand15 mm ID conical connector System Pressure Gauge: Range: -20-100¢mH/O Accuracy: 42:5% full scale 'Bag/Mechanical Ventilation Switch: Type: Bi-stable Control: the switch between manual ventilation and ventilator ‘Adjustable Pressure Limiting (APLvalve: Range: 1-75emH0 ‘Tactile nob indication at:>30em 4,0 Accuracy: £10cmH,0 Startpressure:1emH,0 Breathing Circuit Parameters: Compliance: ‘S4mU/100Pa ‘Automatically compensates for compression losses within the breathing circultin ‘mechanicalmode Expiration resistance: <6 cm H,0 @60 L/min Inspiration resistance: <6

Potrebbero piacerti anche