Sei sulla pagina 1di 6

References

Contactors
Reversing contactors for motor control in utilisation category AC-3 (115 to 265 A), pre-assembled
Control circuit: a.c. or d.c.
3-pole reversing contactors (horizontally mounted) (1)
Pre-wired power connections

813149

Standard power ratings of 3-phase motors 50/60 Hz in category AC-3

Operational current in AC-3 440 V up to A 115

LC2 F115

220 V 380 V 660 V 230 V 400 V 415 V 440 V 500 V 690 V 1000 V kW kW kW kW kW kW kW 30 55 59 59 75 80 65

Maximum Contactors operasupplied tional without coil (2) voltage Complete reference Fixing, cabling (3) V 1000 LC2 F115

Weight

kg 7.560

40

75

80

80

90

100

65

150

1000

LC2 F150

7.560

55

90

100

100

110

110

100

185

1000

LC2 F185

10.100

63

110

110

110

129

129

100

225

1000

LC2 F225

14.200

75

132

140

140

160

160

147

265

1000

LC2 F265

16.480

Accessories (to be ordered separately)


Description Power terminal protection shrouds For reversing contactors LC2 F115 Quantity required 2 Reference LA9 F701 Weight kg 0.250

LC2 F150, F185

LA9 F702

0.250

LC2 F225, F265 Auxiliary contact blocks and add-on modules

LA9 F703 See pages 25010/2 to 25010/7

0.250

(1) Fitted with a mechanical interlock without electrical interlocking. Order separately 2 auxiliary contact blocks LAD Np1 to obtain electrical interlocking between the 2 contactors, see page 25010/3. For accessories, see pages 25010/4 to 25010/7 (2) Coils to be ordered separately: - a.c. supply, see pages 25014/2 and 25014/3, - d.c. supply, see page 25014/5. (3) Screw fixing. Power terminals can be protected against direct finger contact by the addition of shrouds, to be ordered separately, see above.

Selection : pages 24565/2 to 24564/3

Dimensions : pages 25013/2 to 25013/4

Schemes : page 25013/5

25012-EN_Ver8.0.fm/2

References (continued)

Contactors
Changeover contactor pairs for control in utilisation category AC-1 (200 to 350 A), pre-assembled
Control circuit: a.c. or d.c.
4-pole changeover contactor pairs (horizontally mounted) (1)
Pre-wired power connections

813150

Utilisation category AC-1 Non inductive loads Maximum operational current < 40 C

Maximum operational voltage

Contactors supplied without coil (2) Complete reference Fixing, cabling (3) LC2 F1154

Weight

LC2 F1854

A 200

V 1000

kg 8.860

250

1000

LC2 F1504

8.860

275

1000

LC2 F1854

12.100

315

1000

LC2 F2254

15.200

350

1000

LC2 F2654

19.480

Accessories (to be ordered separately)


Description Power terminal protection shrouds For changeover pairs LC2 F1154 Quantity required 2 Reference LA9 F706 LA9 F707 Weight kg 0.250 0.250

LC2 F1504, F1854 2

LC2 F2254, F2654 2

LA9 F708

0.250

Auxiliary contact blocks and add-on modules

See pages 25010/2 to 25010/7

(1) Fitted with a mechanical interlock without electrical interlocking. Order separately 2 auxiliary contact blocks LAD Np1 to obtain electrical interlocking between the 2 contactors, see page 25010/3. For accessories, see pages 25010/4 to 25010/7 (2) Coils to be ordered separately: - a.c. supply, see pages 25014/2 and 25014/3, - d.c. supply, see page 25014/5. (3) Screw fixing. Power terminals can be protected against direct finger contact by the addition of shrouds, to be ordered separately, see above.

Selection : pages 24565/2 to 24564/3

Dimensions : pages 25013/2 to 25013/4

Schemes : page 25013/5

25012-EN_Ver8.0.fm/3

Combinations

Contactors
Reversing contactors and changeover contactor pairs LC2 F
Components for assembling 3-pole reversing contactors and changeover contactor pairs, for customer assembly

Horizontally mounted
Reversers assembled using 2 contactors of identical rating, type : LC1 LC1 LC1 LC1 LC1 LC1 LC1 LC1 LC1 LC1 F115 F150 F185 F225 F265 F330 F400 F500 F630 F800

Mechanical interlocks

Sets of power connections


Reversing contactors 3-pole changeover contactor pairs (1) LA9 Fppp82 (2)
1 1/L3 3 1/L2 5 1/L1 1 2/L1 3 2/L2 5 2/L3 L3 6

LA9 Fp970 (2)

LA9 Fppp76 (2)


L1 L2 3 L3

A1

A1

A1

A2

A2

A2

Vertically mounted
Reversers assembled using 2 contactors of identical rating, type : LC1 F115 LC1 F150 LC1 F185 LC1 F225 LC1 F265 LC1 F330 LC1 F400 LC1 F500 LC1 F630 LC1 F800 Reversers assembled using 2 contactors of different ratings, see page 25012/6

Mechanical interlocks
LA9 FF4F LA9 FG4G LA9 FH4H LA9 FJ4J LA9 FK4K LA9 FL4L

LC1 F780

LA9 FX970

(1) For 4-pole changeover contactor pairs, see pages 25012/6 and 25012/7. (2) Complete references: see page 25012/5.

25012-EN_Ver8.0.fm/4

L1

L2

A2

A1

References

Contactors

Reversing contactors and changeover pairs LC2 F


Components for assembling 3-pole reversing contactors and changeover contactor pairs, for customer assembly Control circuit: a.c. or d.c.
Reversers assembled using 2 contactors of identical rating
Contactor type (1) Set of power connections Reference Weight kg Mechanical interlock Kit reference Weight kg

For assembly of 3-pole reversing contactors for motor control


Horizontally mounted LC1 F115 LC1 F150 LC1 F185 LC1 F225 LC1 F265 LC1 F330 LC1 F400 LC1 F500 LC1 F630 or F800 Vertically LC1 F115 LC1 F185 LC1 F225 LC1 F265 LC1 F400 LC1 F500 LC1 F630 LC1 F780 mounted or F150 LA9 FF976 LA9 F15076 LA9 FG976 LA9 F22576 LA9 FH976 LA9 FJ976 LA9 FJ976 LA9 FK976 LA9 FL976 0.600 0.600 0.780 1.500 1.500 2.100 2.100 2.350 3.800 LA9 FF970 LA9 FF970 LA9 FG970 LA9 FG970 LA9 FJ970 LA9 FJ970 LA9 FJ970 LA9 FJ970 LA9 FL970 0.060 0.060 0.060 0.060 0.140 0.140 0.140 0.140 0.150

or F330

or F800

(2) (2) (2) (2) (2) (2) (2) (3)

LA9 FF4F LA9 FG4G LA9 FG4G LA9 FH4H LA9 FJ4J LA9 FK4K LA9 FL4L LA9 FX970 (3)

0.345 0.350 0.350 1.060 1.200 1.200 1.220 6.100

For assembly of 3-pole changeover contactor pairs (4)


Horizontally mounted LC1 F115 LC1 F150 LC1 F185 LC1 F225 LC1 F265 LC1 F330 LC1 F400 LC1 F500 LC1 F630 or F800 LA9 FF982 LA9 F15082 LA9 FG982 LA9 F22582 LA9 FH982 LA9 FJ982 LA9 FJ982 LA9 FK982 LA9 FL982 0.460 0.460 0.610 1.200 1.200 1.800 1.800 2.300 3.400 LA9 FF970 LA9 FF970 LA9 FG970 LA9 FG970 LA9 FJ970 LA9 FJ970 LA9 FJ970 LA9 FJ970 LA9 FL970 0.060 0.060 0.060 0.060 0.140 0.140 0.140 0.140 0.150

Vertically mounted LC1 F115 or F150 (2) LA9 FF4F 0.345 LC1 F185 (2) LA9 FG4G 0.350 LC1 F225 (2) LA9 FG4G 0.350 LC1 F265 or F330 (2) LA9 FH4H 1.060 LC1 F400 (2) LA9 FJ4J 1.200 LC1 F500 (2) LA9 FK4K 1.200 LC1 F630 or F800 (2) LA9 FL4L 1.220 LC1 F780 (3) LA9 FX970 (3) 7.800 (1) To order the 2 contactors: see pages 25008/2 and 25008/3. For the 2 auxiliary contact blocks LAD Np1 required to obtain electrical interlocking between the 2 contactors, see page 25010/ 3. For accessories, see pages 25010/4 to 25010/7. (2) With the exception of contactors LC1 F780, all power connections are to be made by the customer. (3) Double mechanical interlock mechanism with 2 interlock connecting rods and 3 power connecting links. (4) For assembly of 4-pole changeover contactor pairs, see pages 25012/6 and 25012/7.

Selection : pages 24565/2 to 24564/3

Dimensions : pages 25013/2 and 25013/4

Schemes : page 25013/5

25012-EN_Ver8.0.fm/5

Combinations

Contactors
Changeover contactor pairs LC2 F
Components for assembling 3 and 4-pole changeover contactor pairs, for customer assembly

Horizontally mounted
Contactor pairs assembled using 2 contactors of identical rating, type : LC1 F1154 LC1 F1504 LC1 F1854 LC1 F2254 LC1 F2654 LC1 F3304 LC1 F4004 LC1 F5004 LC1 F6304

Mechanical interlocks
LA9 Fp970

Sets of power connections


4-pole changeover contactor pairs (1) LA9 Fppp77
3 1/L3 5 1/L2 1N 7 1/L1 1 2/L1 3 2/L2 5 2/L3 2N 7 N 8 A2 A1

A2

A1

4 L2

L1

Vertically mounted
Contactor pairs assembled using 2 contactors of identical rating, type : LC1 F1154 LC1 F1504 LC1 F1854 LC1 F2254 LC1 F2654 LC1 F3304 LC1 F4004 LC1 F5004 LC1 F6304

Mechanical interlocks
Assembly A LA9 FF4F LA9 FG4G Assembly B LA9 FH4H LA9 FJ4J LA9 FK4K LA9 FL4L Assembly C LA9 FX971

Contactor pairs assembled using 2 contactors of different ratings, type : LC1 F115 or F1154 LC1 F150 or F1504 LC1 F185 or F1854 LC1 F225 or F2254 LC1 F265 or F2654 LC1 F330 or F3304 LC1 F400 or F4004 LC1 F500 or F5004 LC1 F630 or F6304 LC1 F800

Assembly A LA9 FG4F

Assembly B LA9 FH4F, LA9 FH4G LA9 FJ4F, LA9 FJ4G LA9 FK4F, LA9 FK4G LA9 FL4F, LA9 FL4G

Assembly C LA9 FJ4H LA9 FK4H, LA9 FK4J LA9 FL4H, LA9 FL4J and LA9 FL4K

Contactor pairs assembled using 3 contactors of identical or different ratings, type : LC1 F115 or F1154 LC1 F150 or F1504 LC1 F185 or F1854 LC1 F225 or F2254 LC1 F265 or F2654 LC1 F330 or F3304 LC1 F400 or F4004 LC1 F500 or F5004 LC1 F630 or F6304 LC1 F800

LA9 Fp4p4p : see pages 25030/2 and 25030/3.

Important: the contactor ratings must be in decreasing size from top to bottom. (1) For 3-pole changeover contactor pairs, see pages 25012/4 and 25012/5.

25012-EN_Ver8.0.fm/6

L3

References

Contactors
Changeover contactor pairs LC2 F
Components for assembling 3 and 4-pole changeover contactor pairs, for customer assembly Control circuit: a.c. or d.c.

Contactor pairs assembled using 2 contactors of identical rating


For assembly of 4-pole changeover contactor pairs (1)
Contactor type (2) Horizontally mounted LC1 F1154 LC1 F1504 LC1 F1854 LC1 F2254 LC1 F2654 LC1 F3304 LC1 F4004 LC1 F5004 LC1 F6304 Vertically mounted LC1 F1154 or F1504 LC1 F1854 LC1 F2254 LC1 F2654 or F3304 LC1 F4004 LC1 F5004 LC1 F6304 LC1 F7804 Set of power connections Reference Weight kg LA9 FF977 LA9 F15077 LA9 FG977 LA9 F22577 LA9 FH977 LA9 FJ977 LA9 FJ977 LA9 FK977 LA9 FL977 0.460 0.460 0.610 1.200 1.200 1.800 1.800 2.300 3.400 Mechanical interlock Kit reference Weight kg LA9 FF970 LA9 FF970 LA9 FG970 LA9 FG970 LA9 FJ970 LA9 FJ970 LA9 FJ970 LA9 FJ970 LA9 FL970 0.060 0.060 0.060 0.060 0.140 0.140 0.140 0.140 0.150

(3) (3) (3) (3) (3) (3) (3) (4)

LA9 FF4F LA9 FG4G LA9 FG4G LA9 FH4H LA9 FJ4J LA9 FK4K LA9 FL4L LA9 FX971 (4)

0.345 0.350 0.350 1.060 1.200 1.200 1.220 7.800

Contactor pairs assembled using 2 contactors of different ratings


For assembly of 3 or 4-pole changeover contactor pairs
Contactor type(1) At bottom Vertically mounted LC1 F115 or F1154 or LC1 F150 or F1504 At top Mechanical interlock Kit reference Weight kg LA9 FG4F LA9 FG4F LA9 FH4F LA9 FH4F LA9 FJ4F LA9 FK4F LA9 FL4F LA9 FH4G LA9 FH4G LA9 FJ4G LA9 FK4G LA9 FL4G LA9 FJ4H LA9 FK4H LA9 FL4H LA9 FK4J LA9 FL4J LA9 FL4K 0.350 0.350 0.870 0.870 0.930 0.940 0.940 0.860 0.860 0.940 0.940 0.950 1.130 1.130 1.140 1.200 1.210 1.210

LC1 F185 or F1854 or LC1 F225 or F2254

LC1 F265 or F2654 or LC1 F330 or F3304 LC1 F400 or F4004 LC1 F500 or F5004

LC1 F185 or F1854 LC1 F225 or F2254 LC1 F265 or F2654 LC1 F330 or F3304 LC1 F400 or F4004 LC1 F500 or F5004 LC1 F630, F6304 or F800 LC1 F265 or F2654 LC1 F330 or F3304 LC1 F400 or F4004 LC1 F500 or F5004 LC1 F630, F6304 or F800 LC1 F400 or F4004 LC1 F500 or F5004 LC1 F630, F6304 or F800 LC1 F500 or F5004 LC1 F630 or F6304 or F800 LC1 F630 or F6304 or F800

For assembly of reversers using 3 contactors, vertically mounted


See pages 25030/2 and 25030/3. (1) For assembly of 3-pole changeover contactor pairs, see pages 25012/4 and 25012/5. (2) To order the 2 contactors: see pages 25008/2 and 25008/3. For the 2 auxiliary contact blocks LAD Np1 required to obtain electrical interlocking between the 2 contactors, see page 25010/ 3. For accessories, see pages 25010/4 to 25010/7 (3) All power connections are to be made by the customer. (4) Double mechanical interlock mechanism with 2 interlock connecting rods and 4 power connecting links.

Selection : pages 24565/2 to 24564/3

Dimensions : pages 25013/2 to 25013/4

Schemes : page 25013/5

25012-EN_Ver8.0.fm/7