Sei sulla pagina 1di 8

SITE TEST REPORT

Format No. : RRVPNL-STR/C&R /01 FQP Ref No: FQP/ELCTRICAL/C&R/1 0 Rev.: A Date : 18/12/2009

Doc No: RRVPNL--DOC-06


Employer Name: RRVPNL

Project name: 2 X 100 MVA, 220/132 kV, 2 X 50 MVA, 132/33 kV Hybrid GIS Substation at Indra Gandhi Nagar, Jagatpura (Jaipur)

1. TEST REPORT FOR UNDER VOLTAGE/OVER VOLTAGE RELAY 1. Name plate details Make Model / Type Serial No. Rated Voltage Type of Operation indicator 2. 3. Ratio of PT to which Relay is connected Pick-up and drop out test Set Voltage (Volts) : Pick up (Volts) Drop out (Volts) SL.NO 1 2 3 4 4. : : : : : : :

Functional Checks a) b) Correct operation of contacts Correct operation of appropriate indicator/aux. Relay & flag

: : :

2. TEST FORMAT FOR TIME DELAY RELAY 1. Mode/Type Serial No.


Performed by Agency Name Date

: :
Verified by Agency Name Date 1 of 8 Witnessed by Agency Name Date

SITE TEST REPORT


Format No. : RRVPNL-STR/C&R /01 FQP Ref No: FQP/ELCTRICAL/C&R/1 0 Rev.: A Date : 18/12/2009

Doc No: RRVPNL--DOC-06


Employer Name: RRVPNL

Project name: 2 X 100 MVA, 220/132 kV, 2 X 50 MVA, 132/33 kV Hybrid GIS Substation at Indra Gandhi Nagar, Jagatpura (Jaipur)

Rated Volts 2.

Timing check at rated voltage of relay __________________________________________________________________ Set time in Sec. __________________________________________________________________ Operation time in Sec. __________________________________________________________________

3.

Functional Checks (By simulation of contacts operation) a) b) Correct operation of contacts Correct operation of appropriate Indicator / Aux. relay

: : :

3. TEST FORMAT FOR AUXILIARY RELAY 1. 2. Board/Panel No. Name plate details Make
Performed by Agency Name Date

: : :
Verified by Agency Name Date 2 of 8 Witnessed by Agency Name Date

SITE TEST REPORT


Format No. : RRVPNL-STR/C&R /01 FQP Ref No: FQP/ELCTRICAL/C&R/1 0 Rev.: A Date : 18/12/2009

Doc No: RRVPNL--DOC-06


Employer Name: RRVPNL

Project name: 2 X 100 MVA, 220/132 kV, 2 X 50 MVA, 132/33 kV Hybrid GIS Substation at Indra Gandhi Nagar, Jagatpura (Jaipur)

Type Model No. Serial No. Rated Volts 3. Pickup / Drop out check: Pick up volts

: : :

Drop off volts

4.

Functional Checks (By simulators of relay contacts) a) b) Correct operation of contacts Correct Operation of appropriate Indicator/flag.

: : : :

4 Differentials and REF Relay Test: Relay Make: Relay Rating: Relay Type:
Performed by Agency Name Date Verified by Agency Name Date 3 of 8

Aux. Volts: Serial No: Frequency:


Witnessed by Agency Name Date

SITE TEST REPORT


Format No. : RRVPNL-STR/C&R /01 FQP Ref No: FQP/ELCTRICAL/C&R/1 0 Rev.: A Date : 18/12/2009

Doc No: RRVPNL--DOC-06


Employer Name: RRVPNL

Project name: 2 X 100 MVA, 220/132 kV, 2 X 50 MVA, 132/33 kV Hybrid GIS Substation at Indra Gandhi Nagar, Jagatpura (Jaipur)

a) Pickup Test: Phase R Y B b) Bias Test: Phase Bias Setting Primary Bias Secondary Current Bias Current Diff Current Relay Open Pickup Setting (A) Actual Relay Pickup (A) Time (Sec)

c) Instantaneous (High set) Test: Phase High set (A) Current Injected (A) Time of (Sec). Operation

d) Relay operation indication display check: e) Master trip relay operation with relay pickup: REF Relay testing:

OK/NOT OK OK/NOT OK

Setting Given

Pickup

Relay Operation.

Performed by Agency Name Date

Verified by Agency Name Date 4 of 8

Witnessed by Agency Name Date

SITE TEST REPORT


Format No. : RRVPNL-STR/C&R /01 FQP Ref No: FQP/ELCTRICAL/C&R/1 0 Rev.: A Date : 18/12/2009

Doc No: RRVPNL--DOC-06


Employer Name: RRVPNL

Project name: 2 X 100 MVA, 220/132 kV, 2 X 50 MVA, 132/33 kV Hybrid GIS Substation at Indra Gandhi Nagar, Jagatpura (Jaipur)

5. Over Current and Earth Fault Relay: Relay Make: Relay Rating: Relay Type: Aux. Volts: Serial No: Frequency:

Performed by Agency Name Date

Verified by Agency Name Date 5 of 8

Witnessed by Agency Name Date

SITE TEST REPORT


Format No. : RRVPNL-STR/C&R /01 FQP Ref No: FQP/ELCTRICAL/C&R/1 0 Rev.: A Date : 18/12/2009

Doc No: RRVPNL--DOC-06


Employer Name: RRVPNL

Project name: 2 X 100 MVA, 220/132 kV, 2 X 50 MVA, 132/33 kV Hybrid GIS Substation at Indra Gandhi Nagar, Jagatpura (Jaipur)

1) IDMT Characteristics Check: Phase Pickup ln (A) Actual pickup Current Time Delay setting Actual time taken. Remarks

O/C R O/C Y O/C B E/F 2) High set Characteristics Check: Phase Pickup l (A) Actual Pickup current (A) Time delay Setting Actual time taken . Remarks

O/C R O/C Y O/C B E/F

Trip test mode function tested: Master trip relay operation with relay pickup:

OK/NOT OK OK/NOT OK

Performed by Agency Name Date

Verified by Agency Name Date 6 of 8

Witnessed by Agency Name Date

SITE TEST REPORT


Format No. : RRVPNL-STR/C&R /01 FQP Ref No: FQP/ELCTRICAL/C&R/1 0 Rev.: A Date : 18/12/2009

Doc No: RRVPNL--DOC-06


Employer Name: RRVPNL

Project name: 2 X 100 MVA, 220/132 kV, 2 X 50 MVA, 132/33 kV Hybrid GIS Substation at Indra Gandhi Nagar, Jagatpura (Jaipur)

6. CHECK LIST:

SL.NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

DESCRIPTION Checked the healthiness of fuses, links, MCCB, Switches, indication lamps, push buttons, space heater & illumination circuit. Checked the healthiness of AC & DC supply. Checked the healthiness of AC & DC supply. Checked the metering circuit. Checked the metering circuit. Checked the polarity of ammeter, voltmeter etc. Checked the polarity of ammeter, voltmeter etc. Checked door alignment. Checked door alignment. Checked door lock facility. Checked door lock facility. Checked panel to panel bolting for tightness. Checked panel to panel bolting for tightness. Checked cleanliness of the board. Checked cleanliness of the board. Checked for broken glass, switch handle, lamp cover . Checked for broken glass, switch handle, lamp cover . Ensured proper Glanding of external cables. Ensured proper Glanding of external cables. Ensured blanking of unused cable entry holes. Ensured blanking of unused cable entry holes. Checked the circuit breaker operation. Checked the circuit breaker operation. Checked the electrical interlock. Checked the electrical interlock. Relays, meters mounted properly. Checked the Wiring & Terminal connections. Checked the fuses for correct rating and mounting. Check for proper functioning of alarm.

OK

NOT OK

Performed by Agency Name Date

Verified by Agency Name Date 7 of 8

Witnessed by Agency Name Date

SITE TEST REPORT


Format No. : RRVPNL-STR/C&R /01 FQP Ref No: FQP/ELCTRICAL/C&R/1 0 Rev.: A Date : 18/12/2009

Doc No: RRVPNL--DOC-06


Employer Name: RRVPNL

Project name: 2 X 100 MVA, 220/132 kV, 2 X 50 MVA, 132/33 kV Hybrid GIS Substation at Indra Gandhi Nagar, Jagatpura (Jaipur)

SL.NO. 18 19 20 21 22 23 24 25

DESCRIPTION Openings in floor within and outside panels have been sealed off. All covers and door gaskets are intact to make enclosure vermin proof Breaker checked for free movement. Polarity test of CT and PT Manual closing and tripping. HV test of CB, busbar and cables Primary and secondary injection test IR value of bus bar,CB and cables

OK

NOT OK

Performed by Agency Name Date

Verified by Agency Name Date 8 of 8

Witnessed by Agency Name Date

Potrebbero piacerti anche