Sei sulla pagina 1di 80

ENDOPORE , ENDOPORE Hybrid & ENTEGRA Implant Systems

Product Catalog & Prosthetic Procedures

Welcome to the latest edition of the ENDOPORE, ENDOPORE HYBRID & ENTEGRA Product Catalog. This catalog contains items for implant surgery and prosthetic procedures. Innova, the implant platform of Sybron Dental Specialties, is dedicated to providing innovative solutions to dental professionals and to excellence in customer service.

Table of Contents

ENDOPORE

Contents
Endopore Implants with Internal Connection
6 ndopore Implants with Internal E Connection for One-Stage Surgery 7 Case Planning Chart 9 9 9 1 0 Crown and Bridge Restorations Cover Screws/Healing Abutments Cementable Abutments ECO Abutment System Octabutment System

Endopore, Endopore Hybrid and Entegra Implants with External Hex


23 ndopore, Endopore Hybrid and E Entegra External Hex implants for Two-Stage Surgery 24 Endopore 25 Endopore Hybrid 26 Entegra 29 Case Planning Chart 3 2 3 2 33 3 4 3 4 3 5 3 6 36 3 7 38 38 3 9 40 41 Crown and Bridge Restorations Cover Screws Healing Abutments Transfer Copings Implant Analogs Retaining Screws H exed Abutments A ngled Abutments Temporary Titanium Abutments UCLA Abutments Overdenture Restorations Locator System O-Ring Abutment System Dalla Bona Abutment System Overdenture Abutment System UMA System 3

Overdenture Restorations 1 1 Locator System 12 O-Ring Abutment System 12 Dalla Bona Abutment System

Endopore, Endopore Hybrid Implants with Internal Hex


1 3 ndopore and Endopore Hybrid Internal E Hex Implants for Two-Stage Surgery 14 Case Planning Chart 16 16 1 7 1 7 1 7 1 8 18 19 Crown and Bridge Restorations Cover Screws Healing Abutments Transfer Copings Implant Analogs Retaining Screws H exed Abutments A ngled Abutments UCLA Abutments

43 Prosthetic Instrumentation 45 Prosthetic Procedures

Overdenture Restorations 20 Locator System 21 O-Ring Abutment System 2 1 Dalla Bona Abutment System 22 UMA System

Surgical
64 65 68 69 72 73 75 76 Endopore Surgical Kits E ndopore Surgical Instrumentation Endopore Hybrid Surgical Kits Endopore Hybrid Surgical Instrumentation Entegra Surgical Kit Entegra Surgical Instrumentation Surgical Motors & Equipment Regeneration Products

78 Order Form

Note: Product specifications are subject to change without notice. Not all items illustrated at actual size.

ENDOPORE

Innovas Commitment

Innovas Commitment

Quality Assurance Guarantee Innova manufacturing facilities are ISO certified and products in this catalog are labeled with the CE logo, the symbol of approval by the European Economic Community. Implant Guarantee In North America, Innova guarantees all implants for the lifetime of the patient. If an implant should fail at any time, Innova will replace the failed implant and components from Innova at no charge to the practitioner. To make a claim, please contact the Innova Customer Service Center to obtain a guarantee questionnaire. Continuing Education Innova is actively involved in research and development of new technologies to increase treatment alternatives for you and your patients. New technologies require education, therefore, Innova is pleased to sponsor both introductory and advanced continuing education courses given by world renowned clinicians. In North America, Innova is a recognized program provider by the Academy of General Dentistry under the Program Approval for Continuing Education (PACE). Canadian courses are eligible for the Royal College of Dental Surgeons (RCDS) accreditation. To inquire about our wide range of educational products and services to assist in surgical and prosthetic treatments, please contact Innovas Department of Continuing Education at 800.718.5157 or seminars@innovalife.com.

Ordering Procedures

ENDOPORE

Ordering Procedures
International Orders

For orders outside of North America, please contact Innova for your local dealer.

Innova North American Customer Service Center Toll Free: 800.898.6261 E-mail: info@innovalife.com Tel: 416.340.8818 Web: www.innovalife.com Fax: 416.340.0415 To Place An Order Orders may be placed by telephone, fax, e-mail, through the order form on Innovas web site (www.innovalife.com) or with an Innova Representative. For your convenience we have included an order form in this catalog, which may be photocopied and used for future orders. All orders placed before 2:00 pm EST will be processed for shipment the same day. Billing MasterCard, American Express and Visa credit cards are accepted. All invoices are payable net 30 days. Past due balances will be subject to a 1.5% finance charge per month, an amount equal to 18% per annum. Shipping Unless otherwise specified, orders are shipped FOB, Tonawanda, NY (U.S.A. orders) or FOB, Toronto, Canada (Canadian & International orders), freight collect or prepaid with the shipping cost added to the invoice. All internal and external packaging is carefully inspected prior to shipment. If your package is received damaged, do not accept it and immediately call the Innova Customer Service Center. If there are any shortages or questions, please notify the Innova Customer Service Center within 10 days of receipt. Return Policy Please contact the Innova Customer Service Center for a Material Return Authorization Number and shipping instructions prior to returning any product. Product returned must be unopened and undamaged and must be received within 90 days of the invoice date for replacement or credit. All returned products are subject to our standard 15% handling and restocking charges. No product will be accepted for return after 90 days from the invoice date. 5

North American Orders

ENDOPORE

One-Stage: Internal Connection

Endopore Implants with Internal Connection for One-Stage Surgery

The Endopore implants have a standard Morse Taper implant-to-abutment interface and are supplied in both 4.1 mm and 5.0 mm implant diameters, each having a 4.8 mm abutment platform diameter. This allows both 6

the 4.1 mm and 5.0 mm diameter implants to accept the same prosthetic components. Each implant diameter is available with a 1.8 mm or 2.8 mm transgingival collar. A 1 mm low profile cover screw is packaged with each implant.

AP
4.8 mm AP

TC

Length

Item-No.

Implant 4.1 mm
TC

4.8 mm 4.8 mm 4.8 mm 4.8 mm

1.8 mm 2.8 mm 1.8 mm 2.8 mm 1.8 mm 2.8 mm

7 mm 7 mm 9 mm 9 mm 12 mm 12 mm

01S-7I1.8 01S-7I2.8 01S-9I1.8 01S-9I2.8 01S-12I1.8 01S-12I2.8

Length

4.8 mm 4.8 mm

Implant 5.0 mm
Diameter

4.8 mm 4.8 mm 4.8 mm 4.8 mm 4.8 mm 4.8 mm 4.8 mm 4.8 mm

1.8 mm 2.8 mm 1.8 mm 2.8 mm 1.8 mm 2.8 mm 1.8 mm 2.8 mm

5 mm 5 mm 7 mm 7 mm 9 mm 9 mm 12 mm 12 mm

01WS-5I1.8 01WS-5I2.8 01WS-7I1.8 01WS-7I2.8 01WS-9I1.8 01WS-9I2.8 01WS-12I1.8 01WS-12I2.8

AP Abutment Platform TC Transgingival Collar

One-Stage: Internal Connection

ENDOPORE

Case Planning Chart

One-Stage Surgery
Angled Cementable Straight Cementable ECO Abutment Octabutment

Crown

Bridge

Coping

Coping/I

Locking

Non-Locking

Crown

Bridge

Crown

Bridge

Bar

ENDOPORE

One-Stage: Internal Connection

Case Planning Chart

One-Stage Surgery

Locator System

O-Ring System

Dalla Bona System

Impression Stage

Laboratory Processing

Final Restoration

Overdenture

One-Stage: Internal Connection

ENDOPORE

Crown and Bridge Restorations


Cover Screws/Healing Abutments Cover Screw/Healing Abutments A 1 mm cover screw is packaged with each implant. Length 1 mm 2 mm 3 mm 4 mm Length 4.0 mm 5.5 mm 7.0 mm Item-No. 02S-1HS 02S-2HS 02S-3HS 02S-4HS Item-No. 05S-4.0FS 05S-5.5FS 05S-7.0FS

Cementable Abutments Straight Cementable Abutments

9 Angled Cementable Abutments Angle 15 Angle 25 05S-15FA 05S-25FA

15

ECO Abutment System ECO Abutment and Cap Length 5.0 mm (7.0 mm with cap) ECO Analog

Item-No. 05S-5ABUT/WC 06S-ANALOG


7.0 mm 5.0 mm

ECO Abutment

ECO Analog

ECO Coping Indexed ECO Coping Non Indexed

06S-COPING/I 06S-COPING
ECO Coping Indexed ECO Coping Non Indexed

ENDOPORE

One-Stage: Internal Connection

Octabutment System

Item-No.

The Octabutment System is used for all procedures where a screw-retained prosthesis is required, or where a working model incorporating an abutment analog is desired. Octabutment Octabutment Cap with Screw 07S-0010 07S-2100
Octabutment Cap with screw

Octabutment Transfer Coping With Guide Pin Octabutment Analog

07S-0090 07S-0015
Transfer Coping Analog

Temporary Abutment for Octabutment Locking 10 Temporary Abutment for Octabutment Non-locking Note: Temporary abutments include an octabutment retaining screw.

07S-0303 07S-0353
locking non-locking

Plastic Coping for Octabutment Locking Plastic Coping for Octabutment Non-locking Note: Plastic copings include an octabutment retaining screw. Octabutment Retaining Screw Accessories Insertion Tip For the ECO and Cementable Abutment Insertion Tip for Octabutment Driver Housing 0.05 Hex Tip

07S-0203

07S-0253

locking

non-locking

07S-0053

07S-0176 07S-0175 07-0190 06-TWHT


Insertion Tip Insertion Tip for Octabutment Driver Housing Hex Tip 12.5 mm 0.05 Hex Tip

One-Stage: Internal Connection

ENDOPORE

Overdenture Restorations
LOCATOR Abutments The Locator abutment is an attachment with a self-aligning feature. This feature will aid patients in seating their denture and eliminate additional wear from improper seating. With the Locators minimal vertical height, it is ideal where interocclusal space is limited. This abutment can also accommodate up to 40 between implants.
* Not available in the USA.

Impl. mm 4.1/ 5.0 mm 4.1/ 5.0 mm 4.1/ 5.0 mm 4.1/ 5.0 mm 4.1/ 5.0 mm

Collar 0.73 mm 2 mm 3 mm 4 mm 5 mm

Item-No. 08-8950* 08-8951* 08-8952* 08-8953* 08-8954*


4.8 mm Abutment Platform

LOCATOR Attachments Locator Male Processing Package, 10 sets Locator Male Processing Package, 2 sets Each set includes: 1 processing Replacement Male 08-8515, 1 Replacement Male 08-8524/ 08-8527/08-8529, 1 White Block Out Ring 08-8514, 1 Final Cap Locator Replacement Male Clear, 4 Pack Locator Light Retention Replacement Male Pink, 4 Pack Locator Extra Light Retention Replacement Male Blue, 4 Pack Locator Parallel Post 4 Pack Locator Impression Coping 4 Pack Locator Female Analog 5 mm Diameter. 4 Pack Locator Core Tool Locator Abutment Driver 15 mm 21 mm Abutment Driver For latch, 23 mm

Item-No. 08-8519-10 08-8519-2

LOCATOR Attachments Locator Extended Range Replacement Male Green, 4 Pack Locator Extra Light Extended Range Male Red, 4 Pack

Item-No. 11 08-8547 08-8548 08-8515 08-8514 08-9530

08-8524 08-8527 08-8529

Locator Black Processing Replacement Male 4 Pack White Black Out Ring 20 Pack Angle Measurement Guide

08-8517 08-8505 08-8516


Locator Parallel Post Locator Impression Coping Female Analog 5 mm

08-8393

08-8926 08-8927 08-8913

ENDOPORE

One-Stage: Internal connection

Overdenture Restorations
O-Ring Abutment and Dalla Bona Systems The ORS and the Dalla Bona abutments lie flush with the top of the implant when the abutments are inserted into the Endopore One-Stage implants. O-Ring Abutment System Each O-Ring System includes a titanium male abutment and an ORS lab kit which includes a brass abutment analog, metal housing, 3 red O-Rings and 3 white O-Rings. 12 07S-4000 Item-No. Note Please refer to pages 38 39 for Dalla Bona Abutment System and O-Ring Abutment System. Note The red O-Ring is used for laboratory set-up and the white O-Ring is used for the finished overdenture.

Dalla Bona Abutment System Each Dalla Bona System includes a titanium male abutment, a brass abutment analog, a titanium female with a PVC ring and a spacer.

07S-3000

Accessories Driver Housing

Item-No. 07-0190

ORS and Dalla Bona Abutment Driver

07-0140

Dalla Bona Activating Tool An instrument used to increase the retention of an attachment Dalla Bona Deactivating Tool An instrument used to reduce the retention of an attachment

07-1017

07-1018

Two-Stage: Internal Hex

ENDOPORE/ENDOPORE Hybrid

Endopore and Endopore Hybrid Implants with Internal Hex for Two-Stage Surgery

Endopore and Endopore Hybrid Implants with Internal Hex are supplied in both 4.1 mm and 5.0 mm implant platforms. A low profile cover screw is packaged with each implant. SCR Length Item-No. 13

Implant 4.1 mm
SCR

2 mm 2 mm 2 mm

7 mm 9 mm 12 mm

01l-7I2 01l-9I2 01l-12I2

Length

Implant 5.0 mm
2 mm 2 mm 2 mm 7 mm 9 mm 12 mm 01Wl-7I2 01Wl-9I2 01Wl-12I2

Diameter SCR Smooth Coronal Region

AP

AP

Length

Item-No.

Implant 4.0 mm
4.1 mm 4.1 mm
Length

9.5 mm 11 mm

01l-9.5HYB 01l-11HYB

Implant 4.75 mm
5.0 mm 5.0 mm 7.5 mm 9.5 mm 01Wl-7.5HYB 01Wl-9.5HYB

Diameter AP Abutment Platform

ENDOPORE/ENDOPORE Hybrid Internal Hex Internal Hex Two-Stage: Two-Stage:

Case Planning Chart

Flared Healing Abutment

Straight Healing Abutment

14

One- and TwoStage Surgery

Flared Transfer Coping Assembly

Straight Transfer Coping Assembly

Impression Stage

Flared Hexed Abutment

Angled Hexed Abutment

Angled Hexed Abutment

Straight Hexed Abutment

Hexed UCLA Abutment

Non-Hexed UCLA Abutment

Laboratory Processing

15

25

Final Restoration

Crown

Bridge

Two-Stage: Internal Hex

ENDOPORE/ENDOPORE Hybrid

Case Planning Chart

One- and TwoStage Surgery

Straight Healing Abutment

15
Locator O-Ring System (ORS) Dalla Bona System

Impression Stage

System

Laboratory Processing

Final Restoration

Overdenture

ENDOPORE/ENDOPORE Hybrid

Two-Stage: Internal Hex

Crown and Bridge Restorations


Cover Screws Cover Screw (replacement) A low profile cover screw is packaged with each implant. Healing Abutments Straight Healing Abutments The straight healing abutment is used in all situations except where an expanded gingival cuff is desired. 16 Flared Healing Abutments The use of a flared healing abutment allows the gingiva to heal around this expanded profile, where a more natural emergence profile is preferred. Impl. mm 4.1 mm 5.0 mm Item-No. 02I-CS 02WI-CS

Impl. mm 4.1 mm 4.1 mm 4.1 mm 5.0 mm 5.0 mm 5.0 mm 4.1 mm 4.1 mm 5.0 mm 5.0 mm
Width

Length 3 mm 5 mm 7 mm 3 mm 5 mm 7 mm 4 mm 6.5 mm 4 mm 6.5 mm

Width 4.1 mm 4.1 mm 4.1 mm 5.0 mm 5.0 mm 5.0 mm 5.3 mm 5.3 mm 6.8 mm 6.8 mm
Width

Item-No. 02B-3HS 02B-5HS 02B-7HS 02WB-3HS 02WB-5HS 02WB-7HS 02B-4H 02B-6.5H 02WB-4H 02WB-6.5H

Length

Length

Straight Healing Abutment

Flared Healing Abutment

Two-Stage: Internal Hex

ENDOPORE/ENDOPORE Hybrid

Transfer Copings The shape of the transfer coping matches the shape of the corresponding healing abutment and this allows the profile of the gingival cuff to be accurately reproduced in the working model. Straight Transfer Copings For use with straight healing abutments Flared Transfer Copings For use with flared healing abutments Transfer Coping Screw, Long For optional use with transfer copings, when an open tray technique is used

Impl. mm

Length

Item-No.

4.1 mm 5.0 mm 4.1 mm 5.0 mm 4.1/5.0 mm

11 mm 11 mm 11 mm 11 mm 16 mm

06I-CTCA/S 06WI-CTCA/S 06I-CTCA/F 06WI-CTCA/F 06B-TC/SL

17
Straight Transfer Coping Flared Transfer Coping Transfer Coping Screw, Long

Implant Analogs Implant Analogs Material: Stainless Steel

Impl. mm 4.1 mm 4.1 mm 5.0 mm 5.0 mm

Length 9 mm 9 mm 9 mm 9 mm

Qty. 1 5 1 5

Item-No. 06I-PIA 06I-PIA/5 06WI-PIA 06WI-PIA/5

Implant Analogs Material: Aluminum Color: gold

4.1 mm 4.1 mm

9 mm 9 mm

1 5

06I-IA/1 06I-IA

Implant Analogs Material: Aluminum Color: silver

5.0 mm 5.0 mm

9 mm 9 mm

1 5

06WI-IA/1 06WI-IA

Retaining Screws (replacement) For use with hexed and UCLA abutments Titanium Alloy Replacement Screw Gold Alloy Replacement Screw All abutments are packaged with a titanium retaining screw.

Impl. mm

Item-No.

4.1/ 5.0 mm 4.1/ 5.0 mm

05B-2RS 05B-2RS/G

ENDOPORE/ENDOPORE Hybrid

Two-Stage: Internal Hex

Hexed Abutments These abutments are used for cement retained crown or bridge restorations. Straight Hexed Abutments Retaining screw included The straight hexed abutment has a parallel sided transgingival collar.

Impl. mm

Length

Collar

Item-No.

4.1 mm 4.1 mm 4.1 mm 5.0 mm 5.0 mm 5.0 mm

7 mm 9 mm 11 mm 7 mm 9 mm 11 mm

1.5 mm 3.5 mm 5.5 mm 1.5 mm 3.5 mm 5.5 mm

05I-7FN 05I-9FN 05I-11FN 05WI-7FN 05WI-9FN 05WI-11FN

Length Collar

18

Flared Hexed Abutments Retaining screw included The flared hexed abutment is designed for restorations requiring a natural emergence profile.

4.1 mm 5.0 mm

8.5 mm 8.5 mm

2 mm 2 mm

05I-8.5UN 05WI-8.5UN

Length Collar

Angled Abutments Angled Hexed Abutments Retaining screw included Angled abutments compensate for large divergences in implant alignment. Angled guide pins are available in the Prosthetic Instrumentation section (pg. 43-44) of this catalog.

Impl. mm 4.1 mm 4.1 mm 5.0 mm 5.0 mm

Length 11 mm 11 mm 11 mm 11 mm

Angle 15 25 15 25

Item-No. 05I-15FA 05I-25FA 05WI-15FA 05WI-25FA

15

25

Two-Stage: Internal Hex

ENDOPORE/ENDOPORE Hybrid

UCLA Abutments UCLA Abutments UCLA abutments provide a foundation to which wax can be added to shape a screwretained crown or bridge or a custom abutment. A reamer is available to clean out the retaining screw hole in the casting. Gold base abutments have machined surfaces. UCLA Plastic Abutments Retaining screw included Hexed

Impl. mm

Item-No.

Hexed UCLA abutments should be used for custom abutments and for supporting crowns as they will resist the rotational forces associated with single tooth restorations.

4.1 mm 5.0 mm 4.1 mm 5.0 mm

06I-UCLA/H 06WI-UCLA/H 06I-UCLA 06WI-UCLA

Non-Hexed UCLA Gold Base Abutments Non-Ceramic Alloy Retaining screw included Hexed

4.1 mm 5.0 mm 4.1 mm 5.0 mm

06I-UCLA/H/GNC 06WI-UCLA/H/GNC 06I-UCLA/GNC 06WI-UCLA/GNC

19

Non-Hexed

UCLA Plastic Abutment Hexed

UCLA Plastic Abutment Non-Hexed

UCLA Gold Base Abutment Hexed

UCLA Gold Base Abutment Non-Hexed

Important The melting range is 1,400 1,490C (2,550 2,710F), refer to package instructions for further details.

ENDOPORE/ENDOPORE Hybrid

Two-Stage: Internal Hex

Overdenture Restorations
LOCATOR Abutments The Locator abutment is an attachment with a self-aligning feature. This feature will aid patients in seating their denture and eliminate additional wear from improper seating. With the Locators minimal vertical height, it is ideal where interocclusal space is limited. This abutment can also accommodate up to 40 between implants. Impl. mm 4.1 mm 4.1 mm 4.1 mm 4.1 mm 4.1 mm 4.1 mm 5.0 mm 5.0 mm 5.0 mm 5.0 mm 5.0 mm 5.0 mm Item-No. 08-8519-10 08-8519-2 Collar 0.73 mm 1 mm 2 mm 3 mm 4 mm 5 mm 1 mm 2 mm 3 mm 4 mm 5 mm 6 mm Item-No. 08-8145 08-8146 08-8147 08-8148 08-8149 08-8150 08-8164 08-8165 08-8166 08-8167 08-8168 08-8169 Item-No. 08-8547 08-8548 08-8515 08-8514 08-9530

20

LOCATOR Attachments Locator Male Processing Package, 10 sets Locator Male Processing Package, 2 sets Each set includes: 1 processing Replacement Male 08-8515, 1 Replacement Male 08-8524/ 08-8527/08-8529, 1 White Block Out Ring 08-8514, 1 Final Cap Locator Replacement Male Clear, 4 Pack Locator Light Retention Replacement Male Pink, 4 Pack Locator Extra Light Retention Replacement Male Blue, 4 Pack Locator Parallel Post 4 Pack Locator Impression Coping 4 Pack Locator Female Analog 4 mm Diameter. 4 Pack 5 mm Diameter. 4 Pack Locator Core Tool Locator Abutment Driver 15 mm 21 mm Abutment Driver For latch, 23 mm

LOCATOR Attachments Locator Extended Range Replacement Male Green, 4 Pack Locator Extra Light Extended Range Male Red, 4 Pack

08-8524 08-8527 08-8529

Locator Black Processing Replacement Male 4 Pack White Black Out Ring, 20 Pack Angle Measurement Guide

08-8517 08-8505

08-8530 08-8516 08-8393

Locator Parallel Post

Locator Impression Coping

Female Analog 5 mm

08-8926 08-8927 08-8913

Two-Stage: Internal Hex

ENDOPORE/ENDOPORE Hybrid

O-Ring Abutment System (ORS) O-Ring Abutment System The red O-Ring is used for laboratory set-up and the white O-Ring is used for the finished overdenture. The O-Ring abutment system can accommodate up to 5 degrees of divergence between implants. Each O-Ring System includes a titanium male abutment and an ORS lab kit which includes a brass abutment analog, metal housing, 3 red O-Rings and 3 white O-Rings.

Impl. mm 4.1 mm 4.1 mm 4.1 mm 4.1 mm 4.1 mm 4.1 mm 4.1 mm 5.0 mm 5.0 mm 5.0 mm 5.0 mm 5.0 mm 5.0 mm Item-No. 06-ORS 07-0044 06-O/ORS

Collar 1 mm 2 mm 3 mm 4 mm 5 mm 6 mm 7 mm 1 mm 2 mm 3 mm 4 mm 5 mm 6 mm

Length 4 mm 5 mm 6 mm 7 mm 8 mm 9 mm 10 mm 4 mm 5 mm 6 mm 7 mm 8 mm 9 mm

Item-No. 04I-1ORS 04I-2ORS 04I-3ORS 04I-4ORS 04I-5ORS 04I-6ORS 04I-7ORS 04WI-1ORS 04WI-2ORS 04WI-3ORS 04WI-4ORS 04WI-5ORS 04WI-6ORS

O-Ring Accessories O-Ring Lab Kit Metal Housing White O-Rings 10 pack Dalla Bona Abutment System Dalla Bona Abutment System The Dalla Bona abutment is a ball & socket type connector. Its spherical design allows up to 15 degrees divergence between the abutments. Each Dalla Bona System includes a titanium male abutment, a brass abutment analog, a titanium female with a PVC ring and a spacer.

21 Impl. mm 4.1 mm 4.1 mm 4.1 mm 4.1 mm 4.1 mm 4.1 mm 4.1 mm 5.0 mm 5.0 mm 5.0 mm 5.0 mm 5.0 mm 5.0 mm 5.0 mm Item-No. 07-0482 Collar 1 mm 2 mm 3 mm 4 mm 5 mm 6 mm 7 mm 1 mm 2 mm 3 mm 4 mm 5 mm 6 mm 7 mm Length 4 mm 5 mm 6 mm 7 mm 8 mm 9 mm 10 mm 4 mm 5 mm 6 mm 7 mm 8 mm 9 mm 10 mm Item-No. 04I-1DB 04I-2DB 04I-3DB 04I-4DB 04I-5DB 04I-6DB 04I-7DB 04WI-1DB 04WI-2DB 04WI-3DB 04WI-4DB 04WI-5DB 04WI-6DB 04WI-7DB

Dalla Bona Plus Accessories Dalla Bona Plus Keeping the same benefits as the Dalla Bona System, the Dalla Bona Plus female attachment is a gold insert that can be easily replaced and adjusted with Dalla Bona Plus Activating/Deactivating Tool. Dalla Bona Plus Activating/Deactivating Tool An instrument used to increase and reduce the retention of an attachment.

07-0489

ENDOPORE/ENDOPORE Hybrid

Two-Stage: Internal Hex

Dalla Bona Accessories Dalla Bona Lab Kit Includes a brass abutment analog, a titanium female with a PVC ring and a spacer.

Item-No. 07-1012

Dalla Bona Activating Tool An instrument used to increase the retention of an attachment. Dalla Bona Deactivating Tool An instrument used to reduce the retention of an attachment. UMA System UMA System Abutments The UMA (Universal Modification Abutment) system is used for screw retained restorations where it is desired to have the points of attachment superior to the soft tissue. Where there is insufficient clearance to use a UMA or when a sub-gingival separation is desired, a UCLA abutment can be used to achieve separation of the restoration at the implant level. The UMA is a transmucosal collar that should be secured to the implant with 30 Ncm of torque. The UMA screw used to secure the restoration to the abutment is packaged with each UMA plastic coping. A 0.05 hex driver is used to secure the screw which should only be tightened to 20 Ncm.

07-1017

07-1018

Impl. mm 4.1 mm 4.1 mm 4.1 mm 4.1 mm 4.1 mm 4.1 mm 4.1 mm 5.0 mm 5.0 mm 5.0 mm 5.0 mm 5.0 mm

Collar 2.0 mm 3.0 mm 4.0 mm 5.0 mm 6.0 mm 7.0 mm 8.0 mm 2.0 mm 3.0 mm 4.0 mm 5.0 mm 6.0 mm

Item-No. 02I-2.0UMA 02I-3.0UMA 02I-4.0UMA 02I-5.0UMA 02I-6.0UMA 02I-7.0UMA 02I-8.0UMA 02WI-2.0UMA 02WI-3.0UMA 02WI-4.0UMA 02WI-5.0UMA 02WI-6.0UMA

22

Please refer to pages 41 42 for UMA S ystem components.

Two-Stage: External Hex

ENDOPORE/ENDOPORE Hybrid/ENTEGRATM

Endopore, Endopore Hybrid and Entegra Implants with External Hex for Two-Stage Surgery
Endopore, Endopore Hybrid and Entegra Implants with external hex are compatible with a wide variety of prosthetic products for crown and bridge and overdenture restorations including UCLA, UMA, Dalla Bona, Locator, Overdenture and O-Ring Abutment Systems. All implants are packaged with colour coded labels that identify their diameters. All prosthetic components must be matched to the diameter of implant to which they are to be connected. Abutment labels have the same color coding as the corresponding implants.

23

ENDOPORE

Two-Stage: External Hex

Endopore Implants with External Hex


The Endopore External Hex Connection implants are available in three diameters: 3.5 mm, 4.1 mm and 5.0 mm. A low profile cover screw is packaged with each implant. The 4.1 mm and 5.0 mm diameter are available with a 1 mm or 2 mm smooth coronal region. The 3.5 mm diameter implant is available in a 1 mm smooth coronal region. 3.5 mm diameter implant The 3.5 mm diameter implant is packaged in a red labeled box (01M-range). This implant has a 0.9 mm high x 2.0 mm flat-to-flat hex and a UNF thread. 4.1 mm diameter implant The 4.1 mm diameter implants with the industry standard hex are packaged in green labeled boxes (01B-range). These implants have a 0.7 mm high x 2.7 mm flat-to-flat hex and a metric thread. 5.0 mm diameter implant The 5.0 mm diameter implants are packaged in turquoise l abeled boxes (01WB-range). These implants have a 0.9 mm high x 2.7 mm flat-to-flat hex and metric thread.

SCR

24
Length

Diameter SCR 1 mm

SCR

Length

Item-No.

Implant 3.5 mm
1 mm
Length

9 mm

01M-9I1

Implant 4.1 mm
1 mm 2 mm 7 mm 7 mm 9 mm 9 mm 12 mm 12 mm 01B-7I1 01B-7I2 01B-9I1 01B-9I2 01B-12I1 01B-12I2

Diameter

1 mm 2 mm
SCR 2 mm

1 mm 2 mm

Implant 5.0 mm
Length

1 mm 1 mm 2 mm 1 mm 2 mm 1 mm 2 mm

5 mm 7 mm 7 mm 9 mm 9 mm 12 mm 12 mm

01WB-5I1 01WB-7I1 01WB-7I2 01WB-9I1 01WB-9I2 01WB-12I1 01WB-12I2

SCR Smooth Coronal Region

Diameter

Two-Stage: External Hex

ENDOPORE Hybrid

Endopore Hybrid with External Hex


The Endopore Hybrid External Hex Connection implants are available in two diameters: 4.0 mm and 4.75 mm. The implants are packaged with color coded labels that identify their diameters. These implants have a 0.9 mm smooth coronal region. A low profile cover screw is packaged with each implant. 4.1 mm diameter implant The 4.0 mm diameter implant is packaged in a green labeled box (01B-range). These implants have an industry standard hex (0.7 mm high x 2.7 mm flat-to-flat hex) and a metric thread. 5.0 mm diameter implant The 4.75 mm diameter implant is packaged in a turquoise l abeled box (01WB-range). These implants have a 0.9 mm high x 2.7 mm flat-to-flat hex and metric thread.

AP

25 AP Length Item-No.

Implant 4.0 mm
Length

4.1 mm 4.1 mm

9.5 mm 11 mm

01B-9.5HYB 01B-11HYB

Implant 4.75 mm
5.0 mm 5.0 mm
Diameter AP Abutment Platform

7.5 mm 9.5 mm

01WB-7.5HYB 01WB-9.5HYB

ENTEGRATM

Two-Stage: External Hex

Entegra Implants with External Hex


The self-tapping Entegra External Hex Connection implants are available in three diameters: 3.25 mm, 4.0 mm and 4.75 mm. The implants are packaged with a unique no handling, premounted delivery system and the packages have color coded labels that identify their diameters. All implants have a smooth, unthreaded coronal region (SCR) of 1 mm, and are packaged with a low profile cover screw. The Entegra implants are available with the following surface treatments; acid-washed (AE), hydroxylapatite (HA) or titanium plasma sprayed (TPS). Entegra implants of 8 mm and 10 mm in length with a surface treatment have the first two coronal threads untreated. Implants of 13 mm, 15 mm and 18 mm in length have the first three coronal threads untreated. 26 3.5 mm diameter abutment platform These implants have a 3.5 mm diameter abutment platform with a 0.9 mm high x 2.0 mm flat-to-flat hex and a UNF thread. The implants have a 3.25 mm diameter and are packaged in red labeled boxes (03M-range). 4.1 mm diameter abutment platform These implants have a 4.1 mm diameter abutment platform with a 0.7 mm high x 2.7 mm flat-to-flat hex and a metric thread. The implants are available with a 3.25 mm or a 4.00 mm diameter and are packaged in green labeled boxes (03B-range). 5.0 mm diameter abutment platform These implants have a 5.0 mm diameter abutment platform with a 0.9 mm high x 2.7 mm flat-to-flat hex and a metric thread. The implants have a 4.75 mm diameter and are packaged in turquoise labeled boxes (03WB-range).

Two-Stage: External Hex

ENTEGRATM

Acid-Washed (AE)
Platform

Diameter

Length

Item-No.

Abutment Platform 3.5 mm


3.25 mm 3.25 mm 3.25 mm 8 mm 10 mm 13 mm 03M-8S x 3.25AE 03M-10S x 3.25AE 03M-13S x 3.25AE

Abutment Platform 4.1 mm


Length

3.25 mm 3.25 mm 3.25 mm 4.00 mm 4.00 mm 4.00 mm 4.00 mm 4.00 mm

8 mm 10 mm 13 mm 8 mm 10 mm 13 mm 15 mm 18 mm

03B-8S x 3.25AE 03B-10S x 3.25AE 03B-13S x 3.25AE 03B-8S x 4.0AE 03B-10S x 4.0AE 03B-13S x 4.0AE 03B-15S x 4.0AE 03B-18S x 4.0AE

Diameter

Abutment Platform 5.0 mm


4.75 mm 4.75 mm 4.75 mm 4.75 mm 4.75 mm 8 mm 10 mm 13 mm 15 mm 18 mm 03WB-8S x 4.75AE 03WB-10S x 4.75AE 03WB-13S x 4.75AE 03WB-15S x 4.75AE 03WB-18S x 4.75AE

27

Hydroxylapatite (HA)
Platform

Diameter

Length

Item-No.

Abutment Platform 3.5 mm


3.25 mm 3.25 mm 3.25 mm 8 mm 10 mm 13 mm 03M-8S x 3.25HA 03M-10S x 3.25HA 03M-13S x 3.25HA

Abutment Platform 4.1 mm


Length

3.25 mm 3.25 mm 3.25 mm 4.00 mm 4.00 mm 4.00 mm 4.00 mm 4.00 mm

8 mm 10 mm 13 mm 8 mm 10 mm 13 mm 15 mm 18 mm

03B-8S x 3.25HA 03B-10S x 3.25HA 03B-13S x 3.25HA 03B-8S x 4.0HA 03B-10S x 4.0HA 03B-13S x 4.0HA 03B-15S x 4.0HA 03B-18S x 4.0HA

Diameter

Abutment Platform 5.0 mm


4.75 mm 4.75 mm 4.75 mm 4.75 mm 4.75 mm 8 mm 10 mm 13 mm 15 mm 18 mm 03WB-8S x 4.75HA 03WB-10S x 4.75HA 03WB-13S x 4.75HA 03WB-15S x 4.75HA 03WB-18S x 4.75HA

All implants are packaged with a low profile cover screw.

ENTEGRATM

Two-Stage: External Hex

Titanium Plasma Sprayed(TPS) Diameter


Platform

Length

Item-No.

Abutment Platform 3.5 mm


3.25 mm 3.25 mm 3.25 mm 8 mm 10 mm 13 mm 03M-8S x 3.25TPS 03M-10S x 3.25TPS 03M-13S x 3.25TPS

Abutment Platform 4.1 mm


Length

3.25 mm 3.25 mm 3.25 mm 4.00 mm 4.00 mm 4.00 mm 4.00 mm 4.00 mm

8 mm 10 mm 13 mm 8 mm 10 mm 13 mm 15 mm 18 mm

03B-8S x 3.25TPS 03B-10S x 3.25TPS 03B-13S x 3.25TPS 03B-8S x 4.0TPS 03B-10S x 4.0TPS 03B-13S x 4.0TPS 03B-15S x 4.0TPS 03B-18S x 4.0TPS

Diameter

Abutment Platform 5.0 mm


4.75 mm 4.75 mm 4.75 mm 4.75 mm 4.75 mm 8 mm 10 mm 13 mm 15 mm 18 mm 03WB-8S x 4.75TPS 03WB-10S x 4.75TPS 03WB-13S x 4.75TPS 03WB-15S x 4.75TPS 03WB-18S x 4.75TPS

28

All implants are packaged with a low profile cover screw.

Two-Stage: External Hex

ENDOPORE/ENDOPORE Hybrid/ENTEGRATM

Case Planning Chart

One-andTwo-Stage

Flared Healing Abutment

Straight Healing Abutment

29

Impression Stage

Flared Transfer Coping Assembly

Straight Transfer Coping Assembly

Flared Hexed Abutment

Angled Hexed Abutment

Angled Hexed Abutment

Straight Hexed Abutment

Hexed UCLA Abutment

Non-Hexed UCLA Abutment

Laboratory Processing

15

25

Final Restoration

Crown

Bridge

ENDOPORE/ENDOPORE Hybrid/ENTEGRATM

Two-Stage: External Hex

Case Planning Chart

Second Surgery

Straight Healing Abutment

30
Locator System O-Ring System Dalla Bona System Overdenture System

Impression Stage

Laboratory Processing

Final Restoration

Overdenture

Two-Stage: External Hex

ENDOPORE/ENDOPORE Hybrid/ENTEGRATM

Case Planning Chart

UMA Healing Cap

Second Surgery

Standard UMA System Abutment

Single Crown

Bridge, Bar and Clip

O-Ring

31

Impression Stage
Step 1 Step 1

Step 2

Step 2

Laboratory Processing

Final Restoration

Crown

Bridge

Bar

Overdenture

ENDOPORE/ENDOPORE Hybrid/ENTEGRATM

Two-Stage: External Hex

Crown and Bridge Restorations


Cover Screws Cover Screw (replacement) A low profile cover screw is packaged with each implant. Healing Abutments Straight Healing Abutments The straight healing abutment is used in all situations except where an expanded gingival cuff is desired. 32 Impl. mm 3.5 mm 4.1 mm 5.0 mm Impl. mm 3.5 mm 3.5 mm 3.5 mm 4.1 mm 4.1 mm 4.1 mm 5.0 mm 5.0 mm 5.0 mm Flared Healing Abutments The use of a flared healing abutment allows the gingiva to heal around this expanded profile, where a more natural emergence profile is preferred. 3.5 mm 3.5 mm 4.1 mm 4.1 mm 5.0 mm 5.0 mm Item-No. 02M-CS 02B-CS 02WB-CS Length 3 mm 5 mm 7 mm 3 mm 5 mm 7 mm 3 mm 5 mm 7 mm Width 3.5 mm 3.5 mm 3.5 mm 4.1 mm 4.1 mm 4.1 mm 5.0 mm 5.0 mm 5.0 mm 4.5 mm 4.5 mm 5.3 mm 5.3 mm 6.8 mm 6.8 mm Item-No. 02M-3HS 02M-5HS 02M-7HS 02B-3HS 02B-5HS 02B-7HS 02WB-3HS 02WB-5HS 02WB-7HS 02M-4H 02M-6.5H 02B-4H 02B-6.5H 02WB-4H 02WB-6.5H

4 mm 6.5 mm 4 mm 6.5 mm 4 mm 6.5 mm

Width

Width

Length

Length

Straight Healing Abutment

Flared Healing Abutment

Two-Stage: External Hex

ENDOPORE/ENDOPORE Hybrid/ENTEGRATM

Transfer Copings The shape of the transfer coping matches the shape of the corresponding healing abutment and this allows the profile of the gingival cuff to be accurately reproduced in the working model. Straight Transfer Copings For use with straight healing abutments

Impl. mm

Length

Width

Item-No.

3.5 mm 3.5 mm 4.1 mm 4.1 mm 5.0 mm 5.0 mm

11 mm 16 mm 11 mm 16 mm 11 mm 16 mm 11 mm 11 mm 16 mm 11 mm 16 mm 16 mm

3.5 mm 3.5 mm 4.1 mm 4.1 mm 5.0 mm 5.0 mm 4.5 mm 5.3 mm 5.3 mm 6.1 mm

06M-CTCA/S 06M-CTCA/SL 06B-CTCA/S 06B-CTCA/SL 06WB-CTCA/S 06WB-CTCA/SL 06M-CTCA/F 06B-CTCA/F 06B-CTCA/FL 06WB-CTCA/F 06-TC/SL 06B-TC/SL 33

Flared Transfer Copings For use with flared healing abutments

3.5 mm 4.1 mm 4.1 mm 5.0 mm

Transfer Coping Screw, long For optional use with transfer copings, when an open tray technique is used

3.5 mm 4.1/ mm 5.0 mm

Closed Impression
Straight Transfer Copings 11 mm marking marking Flared Transfer Copings 11 mm marking marking

marking

marking

marking

marking

3.5

4.1

5.0

3.5

4.1

5.0

Open Impression

Transfer Coping Screw for optional use 16 mm marking

3.5

4.1 5.0

ENDOPORE/ENDOPORE Hybrid/ENTEGRATM

Two-Stage: External Hex

Implant Analogs Implant Analogs Material: Aluminum

Impl. mm 3.5 mm 3.5 mm 4.1 mm 4.1 mm 5.0 mm 5.0 mm

Length 9 mm 9 mm 9 mm 9 mm 9 mm 9 mm 9 mm 9 mm 9 mm 9 mm 9 mm 9 mm

Qty. 1 5 1 5 1 5 1 5 1 5 1 5
Stainless Steel

Item-No. 06M-IA/1 06M-IA 06B-IA/1 06B-IA 06WB-IA/1 06WB-IA 06M-PIA 06M-PIA/5 06B-PIA 06B-PIA/5 06WB-PIA 06WB-PIA/5

Implant Analogs Material: Stainless Steel

3.5 mm 3.5 mm 4.1 mm 4.1 mm 5.0 mm 5.0 mm

Aluminum

34

3.5

4.1

5.0

3.5

4.1

5.0

Retaining Screws For use with hexed and UCLA abutments

Impl. mm

Item-No.

Replacement Screw Material: Titanium Alloy

3.5 mm 4.1/ mm 5.0 mm 3.5 mm 4.1/ mm 5.0 mm

05-2RS 05B-2RS/G 05M-2RS/G 05B-2RS/G

Replacement Screw Material: Gold Alloy

All abutments are packaged with a titanium retaining screw.

Two-Stage: External Hex

ENDOPORE/ENDOPORE Hybrid/ENTEGRATM

Hexed Abutments These abutments are used for cement retained crown or bridge restorations. Straight Hexed Abutments Retaining screw included The straight hexed abutment has a parallel sided transgingival collar. These abutments are available in both regular (grooved FS) and thick wall (not grooved FN) versions.

Impl. mm

Length

Collar

Item-No.

3.5 mm 3.5 mm 3.5 mm 4.1 mm 4.1 mm 4.1 mm 4.1 mm 4.1 mm 4.1 mm 5.0 mm 5.0 mm 5.0 mm 5.0 mm 5.0 mm 5.0 mm

7 mm 7 mm 9 mm 7 mm 7 mm 9 mm 9 mm 11 mm 11 mm 7 mm 7 mm 9 mm 9 mm 11 mm 11 mm

1.5 mm 1.5 mm 3.5 mm 1.5 mm 1.5 mm 3.5 mm 3.5 mm 5.5 mm 5.5 mm 1.5 mm 1.5 mm 3.5 mm 3.5 mm 5.5 mm 5.5 mm

05M-7FS 05M-7FN 05M-9FN 05B-7FS 05B-7FN 05B-9FS 05B-9FN 05B-11FS 05B-11FN 05WB-7FS 05WB-7FN 05WB-9FS 05WB-9FN 05WB-11FS 05WB-11FN

35

Length Collar FN FS

Length Collar

Flared Hexed Abutments Retaining screw included The flared hexed abutment is designed for restorations requiring a natural emergence profile. These abutments are available in both regular (grooved UF) and thick wall (not grooved UN) versions.

3.5 mm 3.5 mm 4.1 mm 4.1 mm 4.1 mm 5.0 mm 5.0 mm 5.0 mm

8.5 mm 9 mm 8.5 mm 10 mm 11.5 mm 8.5 mm 8 mm 10.5 mm

2 mm 2 mm 2 mm 2 mm 3.5 mm 1.5 mm 1.5 mm 3.5 mm

05M-8.5UN 05M-9UF 05B-8.5UN 05B-10UF 05B-11.5UN 05WB-8.5UN 05WB-8UF 05WB-10.5UN

Length

Length

Collar UN UF

Collar

ENDOPORE/ENDOPORE Hybrid/ENTEGRATM

Two-Stage: External Hex

Hexed Abutments Angled Hexed Abutments Retaining screw included Angled abutments compensate for large divergences in implant alignment. Angled guide pins are available in the Prosthetic Instrumentation section of this catalog, pages 43 44.

Impl. mm 3.5 mm 3.5 mm 4.1 mm 4.1 mm 5.0 mm 5.0 mm

Length 11 mm 11 mm 11 mm 11 mm 11 mm 11 mm

Angle 15 25 15 25 15 25

Item-No. 05M-15FA 05M-25FA 05B-15FA 05B-25FA 05WB-15FA 05WB-25FA

15

25

Temporary Titanium Abutments 36 Temporary Abutments Retaining screw included Hexed Temporary Abutment

Impl. mm

Item-No.

3.5 mm 4.1 mm 5.0 mm

05M-TEMP/H 05B-TEMP/H 05WB-TEMP/H

Non-Hexed Temporary Abutment

3.5 mm 4.1 mm 5.0 mm

05M-TEMP 05B-TEMP 05WB-TEMP

Two-Stage: External Hex

ENDOPORE/ENDOPORE Hybrid/ENTEGRATM

Crown and Bridge Restorations


UCLA Abutments Impl. mm Item-No.

UCLA abutments provide a foundation to which wax can be added to shape a screw-retained crown or bridge or a custom abutment. See the Prosthetic Instrumentation section for the lapping tool used to polish the cast surface that will mate with the implant. A reamer is also available to clean out the retaining screw hole in the casting. Gold base abutments have UCLA Plastic Abutments Retaining screw included Hexed, green Hexed, yellow Hexed, blue Non-Hexed, white Non-Hexed, white Non-Hexed, yellow 3.5 mm 4.1 mm 5.0 mm 3.5 mm 4.1 mm 5.0 mm

machined surfaces and will not require finishing with these tools. Hexed UCLA abutments should be used for custom abutments and for supporting crowns as they will resist the rotational forces associated with single tooth restorations. Non-hexed UCLA abutments should be used for supporting screw retained bridges.

06M-UCLA/H 06B-UCLA/H 06WB-UCLA/H 06M-UCLA 06B-UCLA 06WB-UCLA


Hexed Non-Hexed

37

UCLA Gold Base Abutments Ceramic Alloy Retaining screw included Hexed

Important The melting range is 1232 1260C (2250 2300F), refer to package instructions for further details. 3.5 mm 4.1 mm 5.0 mm 3.5 mm 4.1 mm 5.0 mm 06M-UCLA/H/G 06B-UCLA/H/G 06WB-UCLA/H/G 06M-UCLA/G 06B-UCLA/G 06WB-UCLA/G

Non-Hexed

Hexed

Non-Hexed

UCLA Gold Base Abutments Non-Ceramic Alloy Retaining screw included Hexed Gold Base UCLA Abutment

Important The melting range is 1400 1490C (2550 2710F), refer to package instructions for further details. 3.5 mm 4.1 mm 5.0 mm 3.5 mm 4.1 mm 5.0 mm 06M-UCLA/H/GNC 06B-UCLA/H/GNC 06WB-UCLA/H/GNC 06M-UCLA/GNC 06B-UCLA/GNC 06WB-UCLA/GNC

Non-Hexed Gold Base UCLA Abutment

Hexed

Non-Hexed

ENDOPORE/ENDOPORE Hybrid/ENTEGRATM

Two-Stage: External Hex

Overdenture Restorations
LOCATOR Abutments The Locator abutment is an attachment with a self-aligning feature. This feature will aid patients in seating their denture and eliminate additional wear from improper seating. With the Locators minimal vertical height, it is ideal where interocclusal space is limited. This abutment can also accommodate up to 40 between implants. Impl. 3.5 mm 3.5 mm 3.5 mm 3.5 mm 3.5 mm 4.1 mm 4.1 mm 4.1 mm 4.1 mm 4.1 mm 4.1 mm 5.0 mm 5.0 mm 5.0 mm 5.0 mm 5.0 mm Impl. mm 3.5 mm 3.5 mm 3.5 mm 3.5 mm 3.5 mm 4.1 mm 4.1 mm 4.1 mm 4.1 mm 4.1 mm 4.1 mm 4.1 mm 5.0 mm 5.0 mm 5.0 mm 5.0 mm 5.0 mm 5.0 mm Item-No. 06-ORS 07-0044 06-O/ORS Collar 1 mm 2 mm 3 mm 4 mm 5 mm 0.73 mm 2 mm 3 mm 4 mm 5 mm 6 mm 1 mm 2 mm 3 mm 4 mm 5 mm Collar 1 mm 2 mm 3 mm 4 mm 5 mm 1 mm 2 mm 3 mm 4 mm 5 mm 6 mm 7 mm 1 mm 2 mm 3 mm 4 mm 5 mm 6 mm Item-No. 08-8851 08-8852 08-8853 08-8854 08-8855 08-8681* 08-8682* 08-8683* 08-8684* 08-8685* 08-8696* 08-8691 08-8692 08-8693 08-8694 08-8695 Length 4 mm 5 mm 6 mm 7 mm 8 mm 4 mm 5 mm 6 mm 7 mm 8 mm 9 mm 10 mm 4 mm 5 mm 6 mm 7 mm 8 mm 9 mm Item-No. 04M-1ORS 04M-2ORS 04M-3ORS 04M-4ORS 04M-5ORS 04B-1ORS 04B-2ORS 04B-3ORS 04B-4ORS 04B-5ORS 04B-6ORS 04B-7ORS 04WB-1ORS 04WB-2ORS 04WB-3ORS 04WB-4ORS 04WB-5ORS 04WB-6ORS

* Not available in the USA.

38

Please refer to pages 11 or 20 for Locator Attachments.

O-Ring Abutment System (ORS) O-Ring Abutment System The O-Ring abutment system can accommodate up to 5 degrees of divergence between implants. Each O-Ring System includes a titanium male abutment and an ORS lab kit which includes a brass abutment analog, metal housing, 3 red O-Rings and 3 white O-Rings.

Length Collar

Note: The red O-Ring is used for laboratory set-up and the white O-Ring is used for the finished overdenture. O-Ring Accessories O-Ring Lab Kit Metal Housing White O-Rings 10 pack

Two-Stage: External Hex

ENDOPORE/ENDOPORE Hybrid/ENTEGRATM

Dalla Bona Abutment System Dalla Bona Abutment System The Dalla Bona abutment is a ball & socket type connector. Its spherical design allows up to 15 degrees divergence between the abutments. Each Dalla Bona System includes a titanium male abutment, a brass abutment analog, a titanium female with a PVC ring and a spacer.

Impl. mm 3.5 mm 3.5 mm 3.5 mm 3.5 mm 3.5 mm 3.5 mm 3.5 mm 4.1 mm 4.1 mm 4.1 mm 4.1 mm 4.1 mm 4.1 mm 4.1 mm 5.0 mm 5.0 mm 5.0 mm 5.0 mm 5.0 mm 5.0 mm 5.0 mm Item-No. 07-0482

Collar 1 mm 2 mm 3 mm 4 mm 5 mm 6 mm 7 mm 1 mm 2 mm 3 mm 4 mm 5 mm 6 mm 7 mm 1 mm 2 mm 3 mm 4 mm 5 mm 6 mm 7 mm

Length 4 mm 5 mm 6 mm 7 mm 8 mm 9 mm 10 mm 4 mm 5 mm 6 mm 7 mm 8 mm 9 mm 10 mm 4 mm 5 mm 6 mm 7 mm 8 mm 9 mm 10 mm

Item-No. 04M-1DB 04M-2DB 04M-3DB 04M-4DB 04M-5DB 04M-6DB 04M-7DB 04B-1DB 04B-2DB 04B-3DB 04B-4DB 04B-5DB 04B-6DB 04B-7DB 04WB-1DB 04WB-2DB 04WB-3DB 04WB-4DB 04WB-5DB 04WB-6DB 04WB-7DB

Length

Collar

39

Dalla Bona Plus Accessories Dalla Bona Plus Keeping the same benefits as the Dalla Bona System, the Dalla Bona Plus female attachment is a gold insert that can be easily replaced and adjusted with Dalla Bona Plus Activating/Deactivating Tool. Dalla Bona Plus Activating/Deactivating Tool An instrument used to increase and reduce the retention of an attachment. Dalla Bona Accessories Dalla Bona Lab Kit Includes a brass abutment analog, a titanium female with a PVC ring and a spacer.

07-0489

Item-No. 07-1012

Dalla Bona Activating Tool An instrument used to increase the retention of an attachment. Dalla Bona Deactivating Tool An instrument used to reduce the retention of an attachment.

07-1017

07-1018

ENDOPORE/ENDOPORE Hybrid/ENTEGRATM

Two-Stage: External Hex

Overdenture Abutment System

Impl. mm

Collar

Length

Item-No.

Overdenture Abutments The Overdenture abutment offers a simple solution for stabilizing an overdenture with implants. An O-Ring embedded in the overdenture acrylic engages the undercut of the Overdenture abutment. Alternatively, an insert of polysiloxane material within the overdenture acrylic engages the undercut of the overdenture abutment. Proper preparation with either arrangement will provide resilience in the connection.

3.5 mm 3.5 mm 4.1 mm 4.1 mm 4.1 mm 5.0 mm 5.0 mm 5.0 mm

4 mm 6 mm

6.5 mm 8.5 mm 6.5 mm 8.5 mm 11 mm 6.5 mm 8.5 mm 11 mm

04M-4OA 04M-6OA 04B-4OA 04B-6OA 04B-8.5OA 04WB-4OA 04WB-6OA 04WB-8.5OA

4 mm 6 mm 8.5 mm 4 mm 6 mm 8.5 mm

Collar

40

Overdenture Accessories For use with overdenture abutments Overdenture Abutment Analog 3 pack

Item-No.

06-OAA

O-Ring Set 10 pack

06-O/OA

Two-Stage: External Hex

ENDOPORE/ENDOPORE Hybrid/ENTEGRATM

UMA System UMA System Abutments The UMA (Universal Modification Abutment) system is used for screw retained restorations where it is desired to have the points of attachment superior to the soft tissue. Where there is insufficient clearance to use a UMA or when a sub-gingival separation is desired, a UCLA abutment can be used to achieve separation of the restoration at the implant level. The UMA is a transmucosal collar that should be secured to the implant with 30 Ncm of torque. The UMA screw used to secure the restoration to the abutment is packaged with each UMA plastic coping. A 0.05 hex driver is used to secure the screw which should only be tightened to 20 Ncm. Standard UMA System Abutment he upper diameter for all UMA System T Abutments is 3.85 mm.

Impl. mm 3.5 mm 3.5 mm 3.5 mm 3.5 mm 4.1 mm 4.1 mm 4.1 mm 4.1 mm 4.1 mm 4.1 mm 4.1 mm 5.0 mm 5.0 mm 5.0 mm 5.0 mm

Collar 3.5 mm 4.5 mm 5.5 mm 6.5 mm 2.5 mm 3.0 mm 4.0 mm 5.0 mm 6.0 mm 7.0 mm 8.0 mm 3.5 mm 4.5 mm 5.5 mm 6.5 mm

Item-No. 02M-3.5UMA 02M-4.5UMA 02M-5.5UMA 02M-6.5UMA 02B-2.5UMA 02B-3.0UMA 02B-4.0UMA 02B-5.0UMA 02B-6.0UMA 02B-7.0UMA 02B-8.0UMA 02WB-3.5UMA 02WB-4.5UMA 02WB-5.5UMA 02WB-6.5UMA

41
Collar

UMA Healing Cap UMA Healing Cap 2 mm UMA Transfer Copings UMA Hexed Transfer Coping Single tooth open tray UMA Guide Pin For 07-0090

Item-No. 07-2120

Item-No. 07-0090 07-0062

UMA Non-Hexed Transfer Coping Bridge

07-0080

ENDOPORE/ENDOPORE Hybrid/ENTEGRATM

Two-Stage: External Hex

UMA Analogs Brass Stainless Steel UMA retaining screw included UMA Copings UMA Temporary Non-Hexed Coping UMA retaining screw included UMA Hexed Plastic Coping UMA retaining screw included UMA Non-Hexed Plastic Coping UMA retaining screw included

Item-No. 07-0015 07-0162


Brass Stainless Steel

Item-No. 07-0352

07-0202

07-0252

42

UMA Non-Hexed Gold Coping UMA retaining screw included UMA Replacement Components UMA Non-Hexed Plastic Coping For Bar UMA Retaining Screw Gold Plated Bar Clip CM Rider UMA Bar Kit UMA Bar Kit Includes 4 bars, a spacer bar, 4 retaining screws, 4 plastic cylinders, and 4 gold plated clips

07-0252/G

UMA Temporary Non-Hexed Coping

UMA Hexed Plastic Coping

UMA Non-Hexed Plastic Coping

UMA Non-Hexed Gold Coping

Item-No. 07-0270 07-0052 07-0120 Item-No. 07-5540


UMA Non-Hexed Plastic Coping UMA Retaining Srew Gold Plated Bar Clip

UMA O-Ring System UMA O-Ring System Each abutment is packaged with an ORS lab kit that includes a brass abutment analog, metal housing, 3 red O-Rings and 3 white O-Rings.

Item-No. 07-4400 Note The red O-Ring is used for laboratory set-up and the white O-Ring is used for the finished overdenture.

Prosthetic

ENDOPORE/ENDOPORE Hybrid/ENTEGRATM

Prosthetic Instrumentation
Item-No. Hex Drivers, 0.05 Extra short, 9 mm Short, 13 mm Long, 18 mm

06-HDXS 06-HDS 06-HDL

18 mm 9 mm extra short short 13 mm

43
long

30 Ncm Torque Wrench 20 Ncm Torque Wrench For use with UMA System Ncm Newton centimeters

06-TW30 06-TW20

Driver Housing Driver Extension

07-0190 07-0195
Driver Housing Driver Extension

Driver Tips Fit Driver Housing and Torque Wrenches 0.05 Hex Tip 0.05 Hex Tip Short UMA Abutment Driver ORS and Dalla Bona Abutment Driver 06-TWHT 06-TWHTS 07-1150 07-0140
Hex Tip 12.5 mm 6.5 mm Hex Tip short UMA Abutment Driver ORS and Dalla Bona Abutment Driver

ENDOPORE/ENDOPORE Hybrid/ENTEGRATM

Prosthetic

Prosthetic Instrumentation Latch Driver 0.05 Hex Latch Type Driver

Item-No. 07-0125

UMA Friction Grip Driver Friction driver for UMA non-hexed transfer coping and UMA O-Ring Abutment

07-0004

Guide Pin For angled abutment selection 15 angled 25 angled 44

06-15AAGP 06-25AAGP
15 25

Reamer For use with UMA abutment castings For use with UCLA abutment castings

07-0150 06-REM 07-0155WP

Lapping Tool with guide pin For use with UMA and UCLA abutment castings and all platforms

Waxing Sleeve

06-WS

Prosthetic Procedures

ENDOPORE/ENDOPORE Hybrid/ENTEGRATM

Prosthetic Procedures
The following prosthetic procedures are examples of the most frequently applied prosthetic restorations for the Endopore, Endopore Hybrid and Entegra Dental Implant Systems. The case presentations are shown with external hex components, however the principal concepts are also used for internal hex components. The procedures discussed are only guidelines. Many alternatives exist for the completion of a successful implant restoration.

Case Presentations
Single Tooth Restorations Single, Cemented Unit Using Hexed Titanium Abutment Single, Screw Retained Unit Hexed UCLA Abutment Multiple Tooth Restorations Multiple, Cemented Units Using Hexed Titanium Abutments Multiple, Screw Retained Units Using Non-Hexed UCLA Abutments Multiple, Screw Retained Units Using Non-Hexed UMA Abutments Overdenture Restorations Overdenture with Screw Retained Bar Using Non-Hexed UMA Abutments Overdenture Using O-Ring System Abutments Overdenture Using Dalla Bona Abutments Overdenture Using Overdenture Abutments 45

Note
The prosthetic restoration of dental implants requires special training. The restorative clinician determines whether a product is suitable for the particular application. Improper restoration choice or technique can result in implant and/or restoration failure. For prosthetic courses, contact Innovas Department of Continuing Education at 800.718.5157 or seminars@innovalife.com.

ENDOPORE/ENDOPORE Hybrid/ENTEGRATM

Prosthetic Procedures

Single, Cemented Unit Using Hexed Titanium Abutment


2

7 6 5 4 3

10 11 12 13 14 15

Maxilla

16

Clinical Steps
1 Expose the implant by removing the flared healing abutment with a 0.05 hex driver and rinse with an air-water syringe. Note: If water purity is not confirmed, sterile saline or sterile water is recommended.

46

2 Engage the hex portion of the flared transfer coping onto the hex portion of the implant using a 0.05 hex driver and tighten with finger pressure (left graphic). Note: It is important to take a periapical X-ray to verify the fit between the transfer coping and the implant (right graphic). Note: A long transfer coping screw is available for an open tray technique.

3 Block-out the transfer coping hex opening with a cotton pellet or soft wax to facilitate access after the impression. Inject impression material around the transfer coping (left graphic). Generously fill the customized impression tray with a heavy body impression material and seat the impression tray to take the impression.

4 After taking the impression remove the transfer coping and attach it to the implant analog. Place the transfer coping back into the impression, aligning the flat surface of the transfer coping with the flat surface in the impression (right graphic). Send the impression to the laboratory and include the impression of the opposing arch and a proper bite registration. Note: After the impression has been taken, replace the healing abutment or use a temporary crown fabricated chairside or supplied by the laboratory. Temporary crown: Shorten the temporary abutment to appropriate occlusal scheme. Attach the hexed temporary titanium abutment onto the implant and torque to 20 N/cm. Attach the crown form or shape the resin to the temporary abutment using self-curing resin. Allow for setting, remove and trim acrylic access.

Prosthetic Procedures

ENDOPORE/ENDOPORE Hybrid/ENTEGRATM

Laboratory Steps
5 Stone Master Model: Soft tissue material is injected around the transfer coping before pouring the stone master model. If requested by the clinician the laboratory can create a temporary crown using a temporary abutment.

6 Remove the transfer coping and place the flared hexed titanium abutment onto the implant analog in the stone model. The titanium abutment can be shortened and modified in preparation for the cemented crown. The titanium abutment margins may be prepared subgingival. To facilitate the process, the titanium abutment can be removed and modified as desired by attaching it to an extra implant analog (left graphic). Note: Thickness on the titanium abutment to protect the hex access hole. 7 Wax a coping over the prepared titanium abutment. Cast the coping in precious or semiprecious ceramic alloy. Finish the coping and seat passively onto the abutment. 47

8 Apply porcelain or other veneer material and return the crown to the clinician. A mark can be placed at the buccal surface of the titanium abutment to facilitate the orientation for the dentist.

Clinical Steps
9 Remove the healing abutment or temporary crown. Insert the titanium abutment with a 0.05 hex driver tip and tighten with finger pressure. Take an X-ray. Torque to 30 N/cm. Retighten in 10 minutes. Try-in the crown, evaluate occlusion and esthetics. Block-out the screw access hole with a cotton pellet and cement the final single unit onto the titanium abutment. Equilibrate occlusion as necessary.
Patient Follow-Up: After receiving the crown, the patient is given oral hygiene instructions. Recall appointments are recommended.

ENDOPORE/ENDOPORE Hybrid/ENTEGRATM

Prosthetic Procedures

Single, Screw Retained Unit Using Hexed UCLA Abutment


2

7 6 5 4 3

10 11 12 13 14 15

Maxilla

16

Clinical Steps
1 Expose the implant by removing the flared healing abutment with a 0.05 hex driver and rinse with an air-water syringe. Note: If water purity is not confirmed, sterile saline or sterile water is recommended.

48

2 Engage the hex portion of the flared transfer coping onto the hex portion of the implant using a 0.05 hex driver and tighten with finger pressure (left graphic). Note: It is important to take a periapical X-ray to verify the fit between the transfer coping and the implant (right graphic). Note: A long transfer coping screw is available for an open tray technique.

3 Block-out the transfer coping hex opening with a cotton pellet or soft wax to facilitate access after the impression. Inject impression material around the transfer coping (left graphic). Generously fill the customized impression tray with a heavy body impression material and seat the impression tray to take the impression.

4 After taking the impression remove the transfer coping and attach it to the implant analog. Place the transfer coping back into the impression, aligning the flat surface of the transfer coping with the flat surface in the impression (right graphic). Send the impression to the laboratory and include the impression of the opposing arch and a proper bite registration. Note: After the impression has been taken, replace the healing abutment or use a temporary crown fabricated chairside or supplied by the laboratory. Temporary crown: Shorten the temporary abutment to appropriate occlusal scheme. Attach the hexed temporary titanium abutment onto the implant and torque to 20 N/cm. Attach the crown form or shape the resin to the temporary abutment using self-curing resin. Allow for setting, remove and trim acrylic access.

Prosthetic Procedures

ENDOPORE/ENDOPORE Hybrid/ENTEGRATM

Laboratory Steps
5 Stone Master Model: Soft tissue material is injected around the transfer coping before pouring the stone master model. If requested by the clinician the laboratory can create a temporary crown using a temporary abutment.

6 Remove the transfer coping and attach the hexed gold base UCLA abutment to the analog in the stone model using the retaining screw (left graphic). Shorten the hexed UCLA abutment as necessary for a screw retained crown. Note: The hexed UCLA abutment is recommended for screw retained single crowns to provide anti-rotation. UCLA abutments are available with either a gold or plastic base. The machined gold-based surface provides a more accurate fit than a cast plastic component. 49

7 Contour wax around the hexed UCLA abutment as desired. Sprue, invest, cast and finish the hexed UCLA abutment with an access hole. Note: When using one of Innovas gold base UCLA abutments follow the casting and processing recommendations supplied with the abutment.

8 Apply porcelain or other veneer material while maintaining the access hole and return to the clinician.

Clinical Steps
9 Remove the healing abutment or temporary crown. Insert the crown by engaging the retaining screw (right graphic) with a 0.05 hex driver tip and tighten with finger pressure. Take an x-ray. Torque to 30 N/cm. Retighten in 10 minutes. Place a cotton pellet in the screw access opening before sealing with a composite resin. Equilibrate the occlusion as necessary.
Patient Follow-Up: After receiving the crown, the patient is given oral hygiene instructions. Recall appointments are recommended.

ENDOPORE/ENDOPORE Hybrid/ENTEGRATM

Prosthetic Procedures

Multiple, Cemented Units Using Hexed Titanium Abutments

22 21 20 19 18 17 L

23

24

25

26 27 28 29 30 31

Mandible

32

Clinical Steps
1 Expose the implants by removing the straight healing abutments with a 0.05 hex driver and rinse with an air-water syringe. Note: If water purity is not confirmed, sterile saline or sterile water is recommended.

50

2 Engage the hex portion of the straight transfer copings onto the hex portion of the implants using a 0.05 hex driver and tighten with finger pressure (left graphic). Note: It is important to take a periapical x-ray to verify the fit between the transfer copings and the implants (right graphic). A long transfer coping screw is optional for an open tray technique.

3 Blocks-out the transfer coping hex openings with cotton pellet or soft wax to facilitate access after the impression. Inject impression material around the transfer copings (left graphic). Generously fill the customized impression tray with a heavy body impression material and seat the impression tray to take the impression.

4 After taking the impression remove the transfer copings and attach them to the implant analogs. Place the transfer copings back into the impression, aligning the flat surface of the transfer coping with the flat surface in the impression (right graphic). Send the impression to the laboratory and include the impression of the opposing arch and a proper bite registration. Note: After the impression has been taken, replace the healing abutments or use a temporary crown fabricated chairside or supplied by the laboratory.

Prosthetic Procedures

ENDOPORE/ENDOPORE Hybrid/ENTEGRATM

Laboratory Steps
5 Stone Master Model: Soft tissue material is injected around the transfer copings before pouring the stone master model. If requested by the clinician the laboratory can create a non-hexed temporary bridge using temporary abutments.

6 Remove the transfer copings and place the straight hexed abutments onto the implant analogs. The titanium abutments can be shortened and modified in preparation for the cemented bridge. To facilitate the process, the titanium abutments may be removed and modified as desired by attaching them to extra implant analogs (left graphic). Note: Care should be taken in the selection of abutments as each implant diameter uses a matching abutment with the same diameter. It is important to leave enough height and thickness on the abutments to ensure hex engagement. 7 Wax the copings over the prepared abutments. Sprue, invest, cast and finish the framework for the ceramics. Finish the framework and seat over the abutments. An intraoral try-in is recommended for passive fit verification before applying ceramics. A resin jig may be fabricated to aid the clinician with the orientation of the prepared abutments or alternatively by marking the buccal area of the abutments. 51

8 Apply porcelain or other veneer material to the bridge framework. The final bridge is sent back to the clinician.

Clinical Steps
9 Remove the healing abutments or temporary bridge. Insert the abutments with a 0.05 hex driver tip and tighten with finger pressure. Take an X-ray. Torque to 30 N/cm. Retighten in 10 minutes. Try-in the bridge, evaluate and adjust occlusion as necessary. Block-out the screw access holes with cotton pellets before cementing the bridge into place. Equilibrate occlusion as necessary.
Patient Follow-Up: After receiving the final restoration the patient is given oral hygiene instructions. Recall appointments are recommended.

ENDOPORE/ENDOPORE Hybrid/ENTEGRATM

Prosthetic Procedures

Multiple, Screw Retained Units Using Non-Hexed UCLA Abutments

22 21 20 19 18 17 L

23

24

25

26 27 28 29 30 31

Mandible

32

Clinical Steps
1 Expose the implants by removing the straight healing abutments with a 0.05 hex driver and rinse with an air-water syringe. Note: If water purity is not confirmed, sterile saline or sterile water is recommended.

52

2 Engage the hex portion of the transfer copings onto the hex portion of the implants using a 0.05 hex driver and tighten with finger pressure (left graphic). Note: It is important to take a periapical x-ray to verify the fit between the transfer copings and the implants (right graphic). A long transfer coping screw is optional for an open tray technique.

3 Block-out the transfer coping hex opening with cotton pellets or soft wax to facilitate access after the impression. Inject impression material around the transfer copings (left graphic). Generously fill the customized impression tray with a heavy body impression material and seat the impression tray to take the impression.

4 After taking the impression remove the transfer copings and attach them to the implant analogs. Place the transfer copings back into the impression, aligning the flat surface of the transfer copings with the flat surface in the impression (right graphic). Send the impression to the laboratory and include the impression of the opposing arch and a proper bite registration. Note: After the impression has been taken, replace the healing abutments or use a temporary bridge fabricated chairside or supplied by the laboratory.

Prosthetic Procedures

ENDOPORE/ENDOPORE Hybrid/ENTEGRATM

Laboratory Steps
5 Stone Master Model: Soft tissue material is injected around the transfer copings before pouring the stone master model. If requested by the clinician, the laboratory can create a temporary bridge using the temporary abutments.

6 Remove the transfer copings and screw the non-hexed gold base UCLA abutments into the stone model using the retaining screws. Shorten the non-hexed UCLA abutments as necessary. Note: The non-hexed UCLA abutments are recommended for bridge restorations to facilitate the path of insertion. UCLA abutments are available with either a gold or plastic base. The machined gold-based surface provides a more accurate fit than a cast plastic component. 53

7 Contour wax around the non-hexed UCLA abutments as desired. Sprue, invest, cast and finish the metal substructure with access holes. Apply porcelain or other veneer material. An intraoral try-in is recommended for passive fit verification. Note: When using one of Innovas gold base UCLA abutments follow the casting and processing recommendations supplied with the abutment. Porcelain can be fired directly to the gold base.

8 The final bridge is sent back to the clinician.

Clinical Steps
9 Remove the healing abutments or the temporary bridge. Screw the final restoration into place with a 0.05 hex driver tip and tighten with finger pressure. Take an X-ray. Torque to 30 N/cm. Retighten in 10 minutes. Place cotton pellets in the screw access openings before sealing with composite resin. Equilibrate occlusion.
Patient Follow-Up: After receiving the final restoration the patient is given oral hygiene instructions. Recall instructions are recommended.

ENDOPORE/ENDOPORE Hybrid/ENTEGRATM

Prosthetic Procedures

Multiple, Screw Retained Units Using Non-Hexed UMA Abutments

22 21 20 19 18 17 L

23

24

25

26 27 28 29 30 31

Mandible

32

Clinical Steps
1 Expose the implants by removing the straight healing abutments with a 0.05 hex driver and rinse with an air-water syringe. Note: If water purity is not confirmed, sterile saline or sterile water is recommended.

54

2 Measure the tissue above the implants to determine the appropriate height of the UMA abutments. The UMA abutments should be slightly subgingival for esthetics. Insert the selected UMA abutments with an UMA abutment driver and torque to 30 N/cm (right graphic). Note: It is important to take a periapical x-ray to verify the fit between the UMA abutment and the implant.

3 Engage the UMA transfer copings onto the UMA abutments and tighten with light finger pressure, using the UMA friction grip driver. Inject impression material around the UMA transfer copings. Generously fill the customized impression tray with a heavy body impression material and seat the impression tray to take the impression.

4 After taking the impression remove the UMA transfer copings and attach them to the UMA analogs. Place the UMA transfer copings back into the impression. Send the impression to the laboratory and include the impression of the opposing arch and proper bite registration. Note: Place the UMA healing caps onto the UMA abutments with a 0.05 hex driver with finger pressure only.

Prosthetic Procedures

ENDOPORE/ENDOPORE Hybrid/ENTEGRATM

Laboratory Steps
5 Stone Master Model: Soft tissue material is injected around the UMA transfer copings before pouring the stone master model.

6 Engage the non-hexed UMA plastic or gold bridge copings to the UMA analogs in the stone master model with a 0.05 hex driver. Note: The non-hexed UMA copings are recommended for bridge restorations to facilitate the path of insertion.

7 Contour the wax around the UMA copings. Sprue, invest, cast and trim the UMA coping framework maintaining the access holes. Note: When using a gold base UMA follow the casting and processing recommendations supplied with the coping. Porcelain can be fired directly to the gold base. An intraoral try-in is recommended for passive fit verification before applying the ceramics.

55

8 Apply porcelain or other veneer materials and maintain the access holes. Send the final restoration to the clinician.

Clinical Steps
9 Apply porcelain or other veneer materials and maintain the access holes. Send the final restoration to the clinician. Remove the UMA healing caps or the temporary bridge. Screw the final restoration into place with a 0.05 hex driver tip and tighten with finger pressure. Take an x-ray. Torque to 20 N/cm. Retighten in 10 minutes. Block-out the screw access holes before sealing with composite resin. Equilibrate occlusion as necessary.
Patient Follow-Up: After receiving the final restoration the patient is given oral hygiene instructions. Recall appointments are recommended.

ENDOPORE/ENDOPORE Hybrid/ENTEGRATM

Prosthetic Procedures

Overdenture with Screw Retained Bar Using Non-Hexed UMA Abutments

22 21 20 19 18 17 L

23

24

25

26 27 28 29 30 31

Mandible

32

Clinical Steps
1 Expose the implants by removing the straight healing abutments with a 0.05 hex driver and rinse with an air-water syringe. Note: If water purity is not confirmed, sterile saline or sterile water is recommended.

56

2 Measure the tissue above the implants to determine the appropriate height of the UMA abutments. The UMA abutments should be slightly subgingival for esthetics. Insert the selected UMA abutments with an UMA abutment driver and torque to 30 N/cm (right graphic). Take an x-ray.

3 Engage the UMA transfer copings onto the UMA abutments and tighten with light finger pressure, using the UMA friction grip driver. Apply impression material around the UMA transfer copings (left graphic). Generously fill the customized impression tray with a heavy body impression material and seat the impression tray to take the impression.

4 After taking the impression remove the UMA transfer copings and attach them to the UMA analogs. Place the UMA transfer copings back into the impression. Send the impression to the laboratory and include the impression of the opposing arch. Note: Place the UMA healing caps onto the UMA abutments with a 0.05 hex driver with finger pressure only.

Prosthetic Procedures

ENDOPORE/ENDOPORE Hybrid/ENTEGRATM

Laboratory Steps
5 Stone Master Model: The technician pours the stone master model. A base plate and bite rim are fabricated and sent to the clinician for intraoral registration. After the bite registration is returned, the casts are mounted and a denture tooth setup is completed and returned for an intraoral try-in. Once the try-in is returned to the laboratory, a silicon matrix is fabricated to aid in the proper bar positioning.

6 Engage the non-hexed UMA plastic or gold bridge copings to the UMA analogs in the stone master model with a 0.05 hex driver.

7 Use the silicon matrix to determine the bar position between the UMA bridge copings. The bar should be positioned approximately 1mm above the ridge for hygiene purposes.

57

8 Sprue, invest, cast and finish the bar framework. The bar should be cast with hard precious or semiprecious alloy. (Do not use non-precious alloys). Upon completion send the bar framework to the clinician for an intraoral try-in to verify passive fit. After the registration is returned, place the spacer and clip over the bar. Block-out the bar gingivally with plaster and a thin coping of latex material before the polymerization process and finish the acrylic. Note: The final bar and overdenture are returned to the clinician for insertion. Once the cast bar is available from the laboratory, its passive fit should be confirmed through patient try-in and x-ray. 9 Remove the UMA healing abutments and screw the bar into place with a 0.05 hex driver and tighten with finger pressure. Take an X-ray. Torque to 20 N/cm. Retighten in 10 minutes. Place finished prosthesis over bar and equilibrate if necessary.
Patient Follow-Up: After receiving the overdenture, the patient is given oral hygiene instructions. Recall appointments are recommended.

Clinical Steps

ENDOPORE/ENDOPORE Hybrid/ENTEGRATM

Prosthetic Procedures

Overdenture Using O-Ring System Abutments

22 21 20 19 18 17 L

23

24

25

26 27 28 29 30 31

Mandible

32

Clinical Steps
1 Expose the implants by removing the straight healing abutments with a 0.05 hex driver and rinse with an air-water syringe. Note: If water purity is not confirmed, sterile saline or sterile water is recommended.

58

2 Measure the tissue depth above the implants to determine the appropriate height of the O-Ring male abutments to be used. The shoulder of the abutments should be slightly above the tissue (approximately 2mm). Place the O-Ring abutments onto the implants with the abutment driver and torque to 30 N/cm (left graphic). Note: Tighten the O-Ring abutments with finger pressure only if the healing abutments will be re-inserted after the impression stage.

3 Inject a impression material around the O-Ring abutments. Generously fill the customized impression tray with a heavy body impression material and seat the impression tray to take the impression.

4 After taking the impression, insert O-Ring analogs into the impression. The analogs may be secured with wax or adhesive. Send the impression to the laboratory and include the housings and red processing rings for fabrication of the master cast. Note: Keep the white O-Rings for final insertion or send to the laboratory for completion. The existing denture can serve as a temporary restoration.

Prosthetic Procedures

ENDOPORE/ENDOPORE Hybrid/ENTEGRATM

Laboratory Steps
5 Stone Master Model: The technician pours the stone master model incorporating the O-Ring analogs. A bite rim is fabricated for proper registration and sent back to the clinician. The bite registration is then mounted with the master cast onto the articulator. A base plate bite rim provided by the laboratory is used to determine the proper vertical dimension.

6 Complete the preliminary wax-up on the processing model. An intraoral try-in is recommended for verification of fit and esthetics.

7 Insert the red rubber O-Rings into the metal housings. Place onto the O-Ring analogs. The smaller opening of the housing is positioned occlusally. The housings are blocked out gingivally and occlusally with latex material.

59

8 The acrylic is injected/packed in one step and should be soft before packing, then polymerize the denture. The acrylic is processed and the overdenture is trimmed and finished. Send the overdenture back to the clinician for insertion.

Clinical Steps
9 Insert the white O-Rings if not already in the housing and deliver the final O-Ring overdenture. Equilibrate as necessary. Note: If using an existing denture, the housing in the denture may be cured chairside.
Patient Follow-Up: After receiving the final overdenture, the patient is given oral hygiene instructions. Recall appointments are recommended.

ENDOPORE/ENDOPORE Hybrid/ENTEGRATM

Prosthetic Procedures

Overdenture Using Dalla Bona Abutments

22 21 20 19 18 17 L

23

24

25

26 27 28 29 30 31

Mandible

32

Clinical Steps
1 Expose the implants by removing the straight healing abutments with a 0.05 hex driver and rinse with an air-water syringe. Note: If water purity is not confirmed, sterile saline or sterile water is recommended.

60

2 Measure the tissue depth above the implants to determine the appropriate height of the Dalla Bona male abutments. The shoulder of the Dalla Bona abutments should be slightly above the tissue (approximately 2mm). Place the Dalla Bona abutments onto the implants with the abutment driver and torque to 30 N/cm (left graphic). Take an x-ray. Note: Tighten the Dalla Bona abutments with finger pressure only if the healing abutments will be re-inserted after the impression stage. 3 Inject impression material around the Dalla Bona abutments. Generously fill the customized impression tray with a heavy body impression material and seat the impression tray to take the impression.

4 After taking the impression, insert the Dalla Bona brass analogs onto the impression. The analogs may be secured with wax or adhesive. Send the impression to the laboratory and include the impression of the opposing arch and the Dalla Bona titanium female with the PVC ring and spacer. The existing denture can serve as a temporary restoration.

Prosthetic Procedures

ENDOPORE/ENDOPORE Hybrid/ENTEGRATM

Laboratory Steps
5 Stone Master Model: The technician pours the stone master model incorporating the Dalla Bona analogs. A bite rim is fabricated for proper registration and sent back to the clinician. The bite registration is then mounted with the master cast onto the articulator. A base plate bite rim provided by the laboratory is used to determine the proper vertical dimension.

6 Complete the wax-up on the processing model. An intraoral try-in is recommended for verification of fit and esthetics.

7 Place the Dalla Bona spacer and the titanium female onto the Dalla Bona analogs. Note: Do not remove the rubber coating around the titanium female, as it is used to allow adjustments. The gingival margin of the master cast may be blocked out with latex material if needed.

61

8 The acrylic is packed/injected in one step and should be soft before packing and curing. The acrylic is processed and the overdenture is trimmed and finished. Send the overdenture back to the clinician for insertion.

Clinical Steps
9 The final Dalla Bona overdenture is delivered and adjusted as necessary. Note: If using an existing denture, the housing in the denture may be cured chairside. The Dalla Bona activating and deactivating tools will be required for future adjustments of the retentive titanium female.
Patient Follow-Up: After receiving the final overdenture, the patient is given oral hygiene instructions. Recall appointments are recommended.

ENDOPORE/ENDOPORE Hybrid/ENTEGRATM

Prosthetic Procedures

Overdenture Using Overdenture Abutments

22 21 20 19 18 17 L

23

24

25

26 27 28 29 30 31

Mandible

32

Clinical Steps
1 Expose the implants by removing the straight healing abutments with a 0.05 hex driver and rinse with an air-water syringe. Note: If water purity is not confirmed, sterile saline or sterile water is recommended.

62

2 Measure the tissue above the implants to determine the appropriate height of the overdenture abutments. Place the overdenture abutments onto the implants using a 0.05 hex driver torque to 30 N/cm. Note: Tighten the overdenture abutments with finger pressure only, if the abutments will be reinserted after the impression stage.

3 Use soft wax or cotton pellets to block-out the holes in the overdenture abutment. Inject impression material around the overdenture abutments. Generously fill the customized impression tray with a heavy body impression material and seat the impression tray to take the impression.

4 After taking the impression, insert the overdenture abutment analogs into the impression. Send the impression to the laboratory and include the impression of the opposing arch.

Prosthetic Procedures

ENDOPORE/ENDOPORE Hybrid/ENTEGRATM

Laboratory Steps
5 Stone Master Model: The technician pours the stone master model incorporating the overdenture abutment analogs. A bite rim is fabricated for proper registration and sent back to the clinician. The bite registration is then mounted with the master cast onto the articulator.

6 The O-rings are blocked out gingivally and occlusally with latex material. Option: Silcone liner material may be processed around the overdenture abutments. Proper fabrication with either process provides resilient function.

7 Complete the preliminary wax-up on the processing model. An intraoral try-in is recommended for passive fit verification and esthetics.

63

8 The acrylic should be soft before packing, then polymerize the denture. Option: Insert a silicon liner material within the overdenture acrylic to engage the undercut of the overdenture abutment. Proper fabrication with either process provides resilient function.

Clinical Steps
9 Deliver the final overdenture and equilibrate occlusion as necessary. Note: If using an existing denture, the housing in the denture may be cured chairside.
Patient Follow-Up: After receiving the final overdenture, the patient is given oral hygiene instructions. Recall appointments are recommended.

ENDOPORE

Surgical

Surgical
Endopore Surgical Kits
for use with all Endopore Implants with Internal Connection, Internal Hex and External Hex.

Comprehensive Surgical Kit 64 2.3 mm Round Bur 2.5 mm Twist Drill short 2.5 mm Twist Drill long 3.5 mm Implant Bur, 4.1 mm Implant Bur, 4.1 mm Implant Bur, 4.1 mm Implant Bur, 5.0 mm Implant Bur, 5.0 mm Implant Bur, 5.0 mm Implant Bur, 5.0 mm Implant Bur, Drill Extension 9 mm 7 mm 9 mm 12 mm 5 mm 7 mm 9 mm 12 mm

Item-No. 06-RB 06-2.5TDS 06-2.5TDL 06M-9IB 06-7IB 06-9IB 06-12IB 06W-5IB 06W-7IB 06W-9IB 06W-12IB 06-DE 06M-9TFG/O 06-7TFG/O 06-9TFG/O 06-12TFG/O 06W-5TFG/O 06W-7TFG/O 06W-9TFG/O 06W-12TFG/O 06-PP 06-M/L 06-H 06-HOS 06-PTM 06-TW 06-HDS 06-RO 06-SV 06-ITM/S1

Endopore Osteotome Kit Osteotome Tip #1 Osteotome Tip #2 Osteotome Tip #3 Stainless Steel Punch Tip Punch Handle, straight, Pack of 4 Punch Handle, offset Mallet Osteotome Instrument Tray, empty

Item-No. 06-OT1 06-OT2 06-OT3 06-PTM 06-H 06-HOS 06-M/L 06-ITM/S2

3.5 mm Trial Fit Gage, 9 mm 4.1 mm Trial Fit Gage, 7 mm 4.1 mm Trial Fit Gage, 9 mm 4.1 mm Trial Fit Gage, 2 mm 1 5.0 mm Trial Fit Gage, 5 mm 5.0 mm Trial Fit Gage, 7 mm 5.0 mm Trial Fit Gage, 9 mm 5.0 mm Trial Fit Gage, 2 mm 1 Paralleling Pins. Pack of 4 Mallet Punch Handle, straight Punch Handle, offset Stainless Steel Punch Tip Tip Wrench Hex Driver 0.05 short Radiographic Overlays, Pack of 2 Sterilization Chart, Surgical Video and Manual Surgical Instrument Tray, empty

Surgical

ENDOPORE

Endopore Surgical Instrumentation


Burs and Drills Crestotom For smoothing and levelling of the alveolar crest Initial Perforation (IP) Drill For initial perforation of the compact cortical bone, 2.00 Round Bur 2.3 mm Twist Drill Short, 2.5 mm, total length 30 mm Long, 2.5 mm, total length 39 mm Item-No. 1452

90024

06-RB

06-2.5TDS 06-2.5TDL

65

Implant Burs Implant Burs For implant 3.5 mm

Length

Item-No.

9 mm

06M-9IB

For implant 4.1 mm

7 mm 9 mm 12 mm

06-7IB 06-9IB 06-12IB

For implant 5.0 mm

5 mm 7 mm 9 mm 12 mm

06W-5IB 06W-7IB 06W-9IB 06W-12IB

ENDOPORE

Surgical

Drill Extension Drill Extension Trial Fit Gages/Osteotome Final Tips Trial Fit Gages/Osteotome Final Tips The trial fit gages are threaded to connect to the punch handles. The trial fit gage corresponding to the size of the implant to be placed, acts as the final osteotome tip. Implant 3.5 mm Implant 4.1 mm

Item-No. 06-DE Length Item-No.

9 mm 7 mm 9 mm 1 2 mm

06M-9TFG/O 06-7TFG/O 06-9TFG/O 06-12TFG/O

66

Implant 5.0 mm

5 mm 7 mm 9 mm 1 2 mm

06W-5TFG/O 06W-7TFG/O 06W-9TFG/O 06W-12TFG/O

Paralleling Pin Paralleling Pin For use with 2.5 mm twist drill Mallet and Punch Handles Mallet

Item-No. 06-PP

Item-No. 06-M/L

Punch Handles For use in conjunction with osteotome tips and trial fit gages for osteotome technique straight offset 06-H 06-HOS

straight

offset

Surgical

ENDOPORE

Punch Tips Stainless Steel Punch Tip Stainless steel punch tip for implant placement. For use with all diameters. Connects to punch handle.

Item-No. 06-PTM

Osteotome Punch Tips Osteotome punch tips connect to the punch handles. Osteotome Tip #1 Osteotome Tip #2 Osteotome Tip #3 06-OT1 06-OT2 06-OT3
Tip #1 Tip #2 Tip #3

Wrench and driver Tip Wrench The tip wrench is used for tightening or loosening trial fit gages, punch tip and o steotome tips to the punch handles.

Item-No. 06-TW 67

Hex Driver 0.05 short

06-HDS

13 mm

Cover Screw Trephines Cover Screw Trephines For implant 3.5 mm For implant 4.1 mm For implant 5.0 mm Tissue Punch Tissue Punch The metal tissue punch attaches to the drill handpiece and will cleanly section a 4.3 mm diameter flap of tissue over the implant.

Item-No.

06M-3.5TR/CS 06-4.1TR/CS 06W-5.0TR/CS


for 3.5 mm for 4.1 mm for 5.0 mm

Item-No. 06-TP

ENDOPORE/ENDOPORE Hybrid/ENTEGRATM

Surgical

Endopore Hybrid Surgical Kits

68 Comprehensive Surgical Kit For use with all Endopore Hybrid External & Endopore Hybrid Internal Hex Implants. Surgical Instrument Tray Round Bur 2.5 mm Twist Drill short 2.5 mm Twist Drill long 4.0 mm Implant Bur, 9.5 mm 4.0 mm lmplant Bur, 11 mm 4.75 mm lmplant Bur, 7.5 mm 4.75 mm Implant Bur, 9.5 mm Drill Extension 4.0 mm Trial Fit Gage, 9.5 mm 4.0 mm Trial Fit Gage, 11 mm 4.75 mm Trial Fit Gage, 7.5 mm 4.75 mm Trial Fit Gage, 9.5 mm Paralleling Pin 4.0 mm Bone Tap 4.75 mm Bone Tap Driver Housing Hex Driver 0.05 short Driver Extension Drill Driver Ratchet Wrench Tip Wrench Driver Body long Radiograph Overlays, Pack of 2 06H-IT/S 06-RB 06H-2.5TDS 06H-2.5TDL 06H-9.5IB 06H-11IB 06WH-7.5IB 06WH-9.5IB 06-DE 06H-9.5TFG/O 06H-11TFG/O 06WH-7.5TFG/O 06WH-9.5TFG/O 06-PP 06H-4.0TAP 06H-4.75TAP 07-0190 06-HDS 07-0195 03-DDH 03-RW 06-TW 03-DBL 06H-RO 06H-SV Item-No. Hybrid Osteotome Kit Osteotome Tip #1 Osteotome Tip #2 Osteotome Tip #3 Punch Handle, straight Punch Handle, offset Mallet Osteotome Instrument Tray, empty Item-No. 06H-OT1 06H-OT2 06H-OT3 06-H 06-HOS 06-M/L 06-ITM/S2

Surgical Manual and Video on DVD

Surgical

ENDOPORE Hybrid

Endopore Hybrid Surgical Instrumentation


Endopore Hybrid Instrument Trays Crestotom For smoothing and levelling of the alveolar crest Initial Perforation (IP) Drill for initial perforation of the compact cortical bone, 2.00 Round Bur Round Bur 2.3 mm Twist Drills Twist Drill short 2.5 mm, total length 30 mm Twist Drill long Item-No. 1452

90024

Item-No. 06-RB Item-No. 06H-2.5TDS 06H-2.5TDL

69

Implant Burs Implant Burs For implant 4.0 mm

Length 9.5 mm 11 mm

Item-No. 06H-9.5IB 06H-11IB

For implant 4.75 mm

7.5 mm 9.5 mm

06WH-7.5IB 06WH-9.5IB

Trial Fit Gages Trial Fit Gages For implant 4.0 mm

Length .5 mm 9 11 mm

Item-No. 06H-9.5TFG 06H-11TFG

For implant 4.75 mm

.5 mm 7 .5 mm 9

06WH-7.5TFG 06WH-9.5TFG

ENDOPORE Hybrid

Surgical

Paralleling Pin Paralleling Pin For use with 2.5 mm twist drill Osteotome Hybrid Punch Tips Osteotome Hybrid Punch Tips Osteotome punch tips connect to the punch handles. Osteotome Tip #1 Osteotome Tip #2 Osteotome Tip #3

Item-No. 06-PP

Item-No.

06H-OT1 06H-OT2 06H-OT3


Tip #1 Tip #2 Tip #3

Bone Taps Bone Taps For implant 4.0 mm 70 For implant 4.75 mm Tip Wrench and Driver Tip Wrench The tip wrench is used for tightening or loosening trial fit gages, punch tip and osteotome tips to the punch handles.

Item-No.

06H-4.0TAP 06H-4.75TAP Item-No. 06-TW

Hex Driver 0.05 short

06-HDS

13 mm

Driver Housing and Extension Driver Housing Driver Extension

Item-No. 07-0190 07-0195


Driver Housing Driver Extension

Surgical

ENDOPORE Hybrid

Ratchet Wrench Ratchet Wrench

Item-No. 06-RW

Drill Extension and Driver Driver Extension

Item-No. 07-0195

Drill Extension

06-DE

Drill Driver

03-DDH

Driver Body, long

03-DBL 71

ENTEGRATM

Surgical

Entegra Surgical Kit

72

Comprehensive Surgical Kit 2.3 mm Round Bur 2.0 mm Twist Drill 2.6 mm Twist Drill, Short 2.6 mm Twist Drill, Long 3.0 mm Twist Drill 3.25 mm Twist Drill, Short 3.25 mm Twist Drill, Long 3.75 mm Twist Drill 4.0 mm Twist Drill, Short 4.0 mm Twist Drill, Long 4.5 mm Twist Drill 2.6 mm Paralleling Pins, Pack of 5 3.25 mm Countersink (3.5 mm platform) 3.25 mm Countersink (4.1 mm platform) 4.75 mm Countersink (5.0 mm platform) 3.25 mm Bone Tap 4.0 mm Bone Tap 4.75 mm Bone Tap Drill Extension Depth Gage #1 (8, 10, 18, 21 mm)

Item-No. 06-RB 03-2.0TD 03-2.6TDS 03-2.6TDL 03-3.0TDX 03-3.25TDS 03-3.25TDL 03-3.75TDX 03-4.0TDS 03-4.0TDL 03-4.5TDX 03-2.6PP 03M-3.25CSK 03-3.25CSK 03-4.75CSK 03-3.25TAP 03-4.0TAP 03-4.75TAP 06-DE 03-DG1 Depth Gage #2 (13, 15 mm) Drill Driver Ratchet Wrench Driver Housing Driver Extension Driver Body, Long 3.5 mm Driver Body, Long Hex Driver 0.05 Radiographic Overlay, Pack of 2 Sterilization Chart, Surgical Video and Manual Entegra Surgical Instrument Tray, Empty

Item-No. 03-DG2 03-DDH 03-RW 07-0190 07-0195 03-DBL 03M-DBL 03-HD50 03-RO 03-SV 03-IT/S

Surgical

ENTEGRATM

Entegra Surgical Instrumentation


Item-No. Crestotom For the removal of soft tissue, for smoothing and levelling of the alveolar crest Initial Perforation (IP) Drill for initial perforation of the compact cortical bone, 2.00 Round Bur 2.3 mm Implant Twist Drills Drill sequence by implant diameter 2.0 mm Twist Drill 2.6 mm Twist Drill, short 2.6 mm Twist Drill, long 3.0 mm* Twist Drill 3.25 mm Twist Drill, short 3.25 mm Twist Drilll, long 3.75 mm* Twist Drill 4.0 mm Twist Drill, short 4.0 mm Twist Drilll, long 4.5 mm* Twist Drill Note: Short twist drills have an overall length of 29 mm and the long twist drills are 38 mm. Paralleling Pin 2.6 mm (For use with the 2.6 mm twist drill) Countersinks 3.25 mm (For use with 3.25 mm implant with 3.5 mm platform) 3.25 mm (For use with 3.25 mm implant with 4.1 mm platform) 4.75 mm (For use with 4.75 mm implant with 5.0 mm platform) Bone Taps 3.25 mm (For use with the 3.25 mm implant) 4.0 mm (For use with the 4.0 mm implant) 4.75 mm (For use with the 4.75 mm implant) 1452

90024

06-RB

03-2.0TD 03-2.6TDS 03-2.6TDL 03-3.0TDX* 03-3.25TDS 03-3.25TDL 03-3.75TDX* 03-4.0TDS 03-4.0TDL 03-4.5TDX*
*Oversized drills are supplied for use in Type 1 bone, when necessary to expand the osteotomy for ease of insertion.

73

03-2.6PP 03M-3.25CSK 03-3.25CSK 03-4.75CSK 03-3.25TAP 03-4.0TAP 03-4.75TAP

ENTEGRATM

Surgical

Entegra Surgical Instrumentation


Item-No. Drill Extension 06-DE

Depth Gage Depth Gage #1 (For use with the 8, 10, and18 mm implants) Depth Gage #2 (For use with the 13 and 15 mm implants)

03-DG1 03-DG2

74

Drill Driver

03-DDH

Ratchet Wrench

03-RW

Driver Housing Driver Extension

07-0190 07-0195
Driver Housing Driver Extension

Driver Body, Long Driver Body, Long (Extension for insertion of the 3.25 [with the 4.1 mm platform], 4.0 and 4.75 mm implants) 3.5 mm Driver Body, Long (Extension for insertion of the 3.25 mm implant with the 3.5 mm platform) Hex Driver 0.05

03-DBL

03M-DBL

03-HD50

Surgical

ENDOPORE/ENDOPORE Hybrid/ENTEGRATM

Surgical Motors and Equipment


Item-No. W&H Motors and Accessories Elcomed SA200-C Surgical Motor Elcomed SA200 Surgical Motor ImplantMed Surgical Motor Elcomed 200 & ImplantMed Travel Case 20:1 Surgical Contra-Angle Handpiece 20:1 Surgical Contra-Angle Handpiece 1:2,7 Surgical Contra-Angle Handpiece 1:1 Surgical Straight Handpiece 1:2 Surgical Angled Handpiece Sterile Saline Tubing (Pack of 10) Elcomed SA200/100 Tube Clamps (Pack of 10) ImplantMed Tube Clamps (Pack of 5) Elcomed SA200/100 Irrigation Spike Assembly ISM/ImplantMed Irrigation Spike w/ Roller Clamp Elcomed SA200 Feed Tube w/ Connectors Elcomed 100 Feed Tube w/ Connectors ISM/ImplantMed Feed Tube w/ Connectors Elcomed SA200 Feed Tubes (Pack of 3) Elcomed 100 Feed Tubes (Pack of 5) ISM/ImplantMed Feed Tubes (Pack of 3) Internal Bur Coolant Tube Sterilizing Protector Irrigation Spike Tube Y-Connector Slow-Blow 4A Fuse 115V Y-Connector Tube Assembly (Pack of 2) Split-Control Bone Spreading and Condensing System Complete System Initial Bur, 1.8 mm Initial Bur, 1.0 mm Osteotomy Disk Pilot Burs Expansion Burs Spreaders Wrench Carriers Ratchet System Complete System Adapter Torque Ratchet Handle Short RA Adapter Long RA Adapter

09-ELCO 200-C 09-ELCO 200 09-ISM 09-IMPCC 09-EMHP (WI-75E) 09-EMHP (WS-75E) 09-EMHP (1:2,7) 09-EMHP (S11) 09-EMHP (S12) 09-EMST 09-EMTC 09-IMTC 09-EMIS 09-EMIS/C 09-SAFT/C 09-EMFT/C 09-IMFT/C 09-SAFT 09-EMFT 09-IMFT 09-EMIB 09-EMSP 09-EMIS/T 09-EMYC 09-EMFUSE 09-EMYCT

75

INN-SC0I 186 RF 859F 231 DC A1001/D1001 A1003/D1003 A1005 to F1005 CA00S CAOKG/CAOOG CA3900RA 39CA2RA CA0RA 39CA2RA 39CA3RA

ENDOPORE/ENDOPORE Hybrid/ENTEGRATM

Surgical

Regeneration Products
CytoplastTM Non Resorbable Membranes Cytoplast GBR-200 A high density PTFE membrane protects against biomaterial centered infections. Size 25 mm x 30 mm 12 mm x 20 mm Qty. 4 10 Item-No. GBR-200 GBR-200 SINGLES

76

Cytoplast TXT-200 Micromachined upper surface area of the high density PTFE membrane allows for additional cell adhesion.

25 mm x 30 mm 12 mm x 20 mm

4 10

TXT-200 TXT-200 SINGLES

Cytoplast TI-250 A high density PTFE membrane with a titanium reinforcement.

25 mm x 30 mm 12 mm x 20 mm

2 4

Ti-250 Ti-250 SINGLES

CytoplastTM Resorbable Membranes Cytoplast RTM Cytoplast RTM is a type 1 bovine collagen matrix and is indicated for use in guided tissue regeneration procedures to enhance wound healing. Cytoplast RTM offers the following benefits: ptimized flexibility and rigidity O for better space maintenance igher mechanical strength for H membrane stabilization in situ redictable resorption time of 26 to 38 weeks P

Size

Qty.

Item-No.

15 x 20 mm 20 x 30 mm 30 x 40 mm

1 1 1

RTM1520 RTM2030 RTM3040

Alphabetical order

ENDOPORE

Cytoplast PTFE Sutures CS-04 CS-05 CS-06 CS-06 Perio CS-06 Premium DynaGraft II DynaGraft II Putty and Gel are powerful mixtures of demineralized bone matrix (DBM) in a reverse phase medium which thickens at body temperature to keep the DBM at the surgical site. DynaGraft II holds up to irrigation and remains where the patient needs it most. Every lot of DBM used in DynaGraft II is tested in a validated in vitro assay to ensure it is osteoinductive. DynaGraft II Putty

Compares in Diameter Needle USP 2-0 USP 3-0 USP 4-0 USP 4-0 USP 4-0 Qty. per box C-6 C-22 C-22 T-22 C-3 Item-No.

Compare FS-2 FS-3 FS-3 TF P-3

Point

Description 18.7mm 3/8 Circle Reverse Cutting 16.3mm 3/8 Circle Reverse Cutting 16.3mm 3/8 Circle Reverse Cutting 12.7mm 1/2 Circle Taper Point 13.1mm 3/8 Circle Premium Reverse Cutting

77

5.0 cc 2.5 cc 1.0 cc 5.0 cc 1.0 cc 0.5 cc

02-2010-050 02-2010-025 02-2010-010 02-2000-050 02-2000-010 02-2000-005

DynaGraft II Gel

Innova Implant Systems

Order Form

Order Form
Please fax completed form to Innova Customer Service at 416.340.0415 Billing Information
Customer Name Order Date Street Telephone Order Placed By City Fax Account No. P.O. No. Province/State E-mail Postal/Zip Code

Shipping Information 78
Name Street City Province/State Postal/Zip Code Telephone

Shipping Method United States


8 am (where available) Priority (10:30 am) Standard Overnight (before 5 pm) 2 Days (before 5 pm) 3 Days (before 5 pm) Saturday (before 5 pm)

Canada
9 a.m. (where available) Priority (10:30 am or noon) Standard (5 pm) 2 Days (before 5 pm)

Payment Method
COD

Bill Net 30

Credit Card: Visa Mastercard Amex


Expiry Date Signature

Credit Card No. Name of Cardholder

Product Order
Catalog Number Quantity Description

Endopore is still the worlds shortest implant with 16 years of proven clinical success!

Endopore

Hybrid

PITT-EASY

Anatomic

A World of Implant Solutions


Innova has been a leading innovator in the development of dental implants for nearly two decades. Our complete line of implant systems including Endopore, still the worlds shortest implant is used with great success by practitioners around the globe. Products our comprehensive catalog of implant systems provides world-class solutions for every patients needs. Education we are dedicated to advancing your skills and knowledge by providing a full range of educational programs and seminars. For a complete listing of our worldwide educational offerings visit www.innovalife.com Service were always there for you, with personal, professional support right in your office. Future-driven we are continuously developing the practical and unique implant solutions you need today and will need tomorrow. Guaranteed success every Innova implant and component is guaranteed for the lifetime of the patient.

Innovation. Its in our name. In our products. In your future!

Innova Corporation Corporate Office 522 University Ave, Suite 1200 Toronto, ON M5G 1W7 Canada +1.416.340.8818 Toll free 800.898.6261
06/11 PC 001 EN

Regional Offices: Sydney, Australia +61.2.9363.0224 Bremen, Germany +49.421.43939.0

www.innovalife.com

Potrebbero piacerti anche