Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
TYPE Wind turbine class Rated powerkW Cut-in wind speedm/s Rated wind speedm/s Cut-out wind speedm/s Survival wind speedm/s Operation Operating temperature range SL1500/70 IEC //S 1500 3 12 25 59.5/52.5 Normal temperature type -15~+45 Survival temperature () Longevity of design (year) Averaged availability of wind farm (%) Rotor Rotor diameterm Swept aream Rated rotational rpm Number of blades Rotational direction (from up wind) speed/range
2
SL1500/77 IEC 1500 3 11 20 59.5/52.5 Low temperature type -30~+45 -45~+45 Normal temperature type -15~+45 -25~+45 20 95 77.4 4657 17.4/9.7~19 3 clockwise Low temperatur e type -30~+45 -45~+45
SL1500/82 IEC / 1500 3 10.5 20 59.5/52.5 Normal temperature type -15~+45 -25~+45 20 95 82.9 5398 17.4/9.7~19 3 clockwise Low temperature type -30~+45 -45~+45
PROPRIETARY INFORMATION
Cone angle ( Tilt angle ( Power Regulation Blade length (m) Blades Material Type Number of Phase Rated powerkW Rated output voltageV FrequencyHz Rated rotational rpm Power factor Protection level Insulation level Generator Step-up transformer data Transformer rating Number transformer Winding PROPRIETARY INFORMATION of speed/range
Generator
Double-fed induction
Double-fed induction
Double-fed induction
generator
3 1520 690 60 2096/1200~2400 Capacitive 0.95 inductive 0.9 Rated: 1 IP54 F 35kV/0.69kV
generator
3 1520 690 60 2096/1200~2400 Capacitive 0.95 inductive 0.9 Rated: 1 IP54 F 35kV/0.69kV
generator
3 1520 690 60 2096/1200~2400 Capacitive 0.95 inductive 0.9 Rated: 1 IP54 F 35kV/0.69kV
1 Dyn11
1 Dyn11
1 Dyn11
Connection Impedance Drive stage Gearbox Drive ratio Rated power (kW) Brake system Control system Major brake system Minor brake system Type Capacity (KVA) input/output voltage (VAC) Converter Input/output current (A) Range of input/output frequency (Hz) Tower type Hub height m Type/design Yaw system Drive Range of yaw speed Pitch system Pitch bearing type Pitch drive (/min) 7% 3 1:104 1700 Air-braking mechanical braking PLC 500 690/0~700 200/500 601% / 020 7% 3 1:120 1700 Air-braking mechanical braking PLC 500 690/0~700 200/500 601% / 020 7% 3 1:120 1700 Air-braking mechanical braking PLC 500 690/0~700 200/500 601% / 020
Multistage planetary gear driven by conversion asynchronous motor 18.3~23.2 4 points contact ball bearing Multistage planetary gear
Multistage planetary gear driven by conversion asynchronous motor 18.3~23.2 4 points bearing contact ball
Multistage planetary gear driven by conversion asynchronous motor 18.3~23.2 4 points bearing contact ball
PROPRIETARY INFORMATION
driven by conversion asynchronous motor Lightning protection Design standard Resistance of earthing Nacelle Weight Rotor Blades kg kg kg IEC61024 ambient 4 55614 16462 35500 and local
driven by conversion asynchronous motor IEC61024 ambient 4 55614 16462 35900 and local
driven by conversion asynchronous motor IEC61024 ambient 4 55614 16462 36300 and local
If annual mean wind speed is about 6 to 7 m/s in local wind farm, we suggest that SL1500/77 or SL1500/82 wind turbines may be installed here. Especially, the later one is a better choice.
PROPRIETARY INFORMATION