Sei sulla pagina 1di 14

Tank Design Guide

When you order a tank we ask that you fax us a drawing of the tank with the fitting locations marked on the drawing. When you make a drawing for us, please take care to make your drawing accurate and easy for us to interpret. Please follow the guidelines below. Discharge Fittings (waste) We use dip tubes for discharge, they can be located on the top side or the top of a vertical side. Dip tubes are 1.5" female pipe thread and will accept straight or 90 degree pipe to hose adapters. Di p tubes extend down to the bottom of the tank. You will need 4.5" of clearance from the sidewall of the tank for our standard fittings and 2.75" for our low profile fittings. Inlet and Vent fittings Inlet and vent fittings can be located on the top or the top of a vertical side of the tank. The inlet fitting is 1.5" female pipe thread and the vent can be .5" or .75" female pipe thread. The inlet fitting requires 4.5" of clearance from the sidewall of the tank for a 90-degree fitting. Vent fittings require 2" of clearance for .5" 90 degree fittings and 2.25" of clearance for .75" fittings off the sidewall of the tank. Suction Fittings (water tanks) Suction fittings can be at the bottom of the tank or the bottom of a sidewall of the tank. Suction fittings can be .5", .75", or 1". How to mark the Drawing
y y

Download and print the tank diagram. Use solid lines for visible fittings and use dotted lines for "blind side" fittings.

Identify each fitting - by size, (.5" or 1.5" etc.), function, (inlet, diptube, suctio n or vent.) and location (visible or blindside on the drawing, not after the tank is installed) Use the example below for a reference. Show each fitting on at least two views on the drawing.

Fiberglass Underground Water Tank Accessories


1

Fiberglass manway extensions for 3 foot standard bury depth


y y y y

Standard inside diameters are: 20" - 24" - 30" Stainless steel hardware and gaskets included Specify bury depth if other than 36 inches Slip-In poly plug covers available for manhole or grade box applications

4 inch I.D. cam-lock inspection hatch for bolted FRP covers


y y y y

Cast aluminum with brass closure arms for padlock Includes NPT female fitting on manway cover Used to visually check level without removing cover bolts May be used for refilling at 50 PSI maximum pressure

30 inch I.D. fiberglass manway with easy access hinged cover


y y y y y y

Available only on 30" ID size Hinged overlapping "shoe box" style cover conforms to AWWA potable standards Includes stainless hardware and manway gasket Hinged cover flanges have holes for a padlock (by others) Specify bury depth if other than 36 inches Less secure than bolted design against forced entry by vandals

48 inch I.D. weather tight manway enclosure vault for 36 inch bury depth
y y y y y y

Overlapping domed dust cover with 2 stainless handles Chain set and lock are not included (by others if needed) 20 inch ID internal manway recommended for space Manway may be centered or offset inside enclosure to make room for tank fittings Some field assembly required Specify bury depth if other than 36 inches

24 and 30 inch O.D. ring collar for low cost plastic culvert riser pipe
y y y y y y y

Plastic corrugated culvert pipe riser not included (by others) Cover at grade not included Not considered water tight Commonly used on septic tanks and rain collection tanks Fiberglass pipe risers and plug covers are available if requested Use locking grade box #7 for security Field assembly required

Fiberglass tank ladders with mounting brackets installed


y y y y

Standard OSHA designs Stainless steel hardware Shipped loose and must be field assembled inside tank Specify NSF potable water use when appropriate

Locking steel grade box with aluminum cover for security


y y y y y y

Aluminum treadbrite cover is not rated for automobile traffic Drop handle and flange holes for a padlock (by others) Specify internal bolted or poly plug cover as needed Shop iron oxide primer finish supplied on steel frame Often used in public areas Available with 26", 32", or 36" square internal opening

20" x 30" polyethylene manway extension for 36 inch standard bury depth below grade
y y y y y y

Gray color, UV resistant Overlapping hinged cover with dust seal and padlock hasp Easy access with ample knee and shoulder room Tank entry opening 20" ID Upper portion inside diameter 30 inches at hinged cover Includes internal safety cover at tank entry point

20 inch I.D. segmented spool type polyethylene manway extension


y y y y y y

Each flanged section is 18 inches tall - face to face Stack and bolt as needed Includes one gasket and stainless bolt kit per section Grey color, UV resistant Specify bolted or plug cover Can UPS ship individually

10

Not available
y

This item is not available at this time

11

4", 6", & 8 inch PVC vent heads


y y y

Stainless steel insect screen inside (8 mesh standard) Slotted external poly guard Includes NPT female tank fitting and PVC adapter

This accessory is not available at this time.

13

This accessory is not available at this time.

14

Hi

water level control

y y y y y y y

Prevents riser "free e-off" from overfilling tank above full level Diverts e cess water slowly into backfill material Includes check valve & filters Includes NPT 2" female tank fitting Do not use when tank is connected to a well or city water line supply For truck water delivery only Often used on Fire isterns

4, 6, & 8 inc over low assemblies


y y y y

Diverts e cess water to remote daylight discharge area Includes swing check valve and heavy metal rodent guard Includes PV stub pipe and hump hose rubber fle connector at tank PV piping run by others

Not availabl

Not availabl

PV riser pipe by others as nee e for proper height

16

6 inch NST- Male dry fire hydrant for suction water supplies
y y y y y y y y

Aluminum NFPA construction with metal cap and chain lanyard Removable strainer plate 45, 90, or straight PVC fitting choice below head NFPA anti-vortex plate and 6 inch internal draw pipe-factory installed Also includes 6 inch female NPT tank fitting, PVC adapter, and PVC elbow PVC riser pipe by others Female swivel and Storz hydrant heads also available Some field assembly required

17

Siamese refill 2.5" X 2.5" NST with clappered female swivels


y y y y y y

Brass NFPA construction Includes top and bottom adapters for PVC riser pipe Includes 4" NPT tank fitting Refill pressure 50 PSI max. PVC riser pipe by others Some field assembly required

18

4 inch through 12 inch flanged fittings with gussets


y y y y y y

May be installed anywhere on tank heads or shell Standard ANSI 150# flat flange face and bolt pattern Gasket and bolts by others Available in standard pipe sizes through 12 inch Tangential shell placement at additional cost Consider using flexible pipeline couplings at all tank fittings

19

Anti-vortex blades in bottom suction fittings


y y y

Used on any outlet line feeding a pump or fire hydrant Decreases water swirl to improve flow rate when tank nears empty Available on flanged or threaded fittings of all sizes

20

NPT tapered fiberglass female pipe thread full and half couplings
y y y

May be installed anywhere on tank heads or shell Available in standard pipe sizes through 8 inch Use full couplings when threads are required both inside and outside the tank

21

4 inch through 16 inch PVC stub pipe bonded through tank head or shell
y y y y y

May be installed anywhere on tank heads or shell Tangential placement at additional cost Connection point for piping both inside or outside tank Consider using flexible pipeline couplings at all tank fittings Suitable for connection with a rubber ring mechanical joint (MJ) or compression fitting

22

Rubber flex member for flanged fiberglass fitting applications


y y y

Mates up with standard 150# ANSI flange and bolt pattern Includes one gasket & stud kit for tank side of coupling only Includes poly protective wrap

y y y

Rated at 75 PSI working pressure Available in standard pipe flange sizes through 12 inch Not NSF listed but suitable for potable water applications

23

Stainless flex members with male tapered pipe threads for pressure inlet and pumped discharge
y y y y

Heavy clear vinyl jacket or stainless steel braid Includes 1 reinforced PVC schedule 80 pipe adapter Vinyl jacket version rated at 25 psi, allows maximum flexibility Braided jacket version rated at 75 psi, but is less flexible

24

4, 6, & 8 inch Hump Hose low pressure flex couplers for PVC stub pipe connections
y y y y y y y

Rated for 25 psi working pressure Fits schedule 40 PVC pipe Connects to tank stub pipe Stainless clamps included Often used on wastewater treatment tanks, overflow connections, and rainwater collection inlet lines Install at or above full tank water level Not for use in bottom of tank discharge flex applications

25

Darco brand Maxi-Flex coupler for low pressure applications


y y y y y y

Stainless body with PVC ends Far more flexible in all directions than traditional rubber types Suitable for seismic areas and expansive clay soils Commonly use as a discharge flex on Fire Service tanks Available with PVC flanges or socket ends Different configurations and PVC adapters are available

y y

Rated at 25 PSI working pressure only when buried below grade Price varies with fitting ends and adapters required

26

Submerged water inlet filter


y y y y y y y y

Manway mount on brass 1 inch pitless adapter Uses universal filter cartridges Easily removed for filter change Includes 1" feed line stainless flex member and PVC adapter Includes adjustable bypass pressure relief valve Must be field installed Requires hole saw and grinder work on site Installation must comply with local plumbing codes

27

Float valve water inlet control


y y y y y y y

Manway mount on brass 1 inch pitless adapter Adjustable float arm for proper air space at top of tank Brass piping and backflow check valve included Includes 1" feed line stainless flex member and PVC pipe adapter Field assembly and piping required Requires hole saw and grinder work on site Installation must comply with local plumbing codes

28

Pump mounting platform bonded to tank floor


y y y y y

24" x 24" flat fiberglass surface Raised 6" above floor for bolt access below platform Rated for 250 pound maximum pump weight Field drill to mount equipment Shield tank wall when drilling downward through platform

29

Water level gauge - mechanically float actuated


y y y y y

Requires no electric power Metal guage body with weather proof clear viewing lens Reads to 108 inches maximum water depth Includes NPT female tank fitting Must be field assembled and calibrated by the installer

30

1 & 2 inch brass pitless adapters


y y y y y y

Brass female pipe thread connections Rated at 75 PSI working pressure Includes braided stainless flex member & PVC pipe adapter Often used with submersible pumps or equipment Lift up slider to easily withdraw pump or equipment for service Field installation requires hole saw and grinder work on site

31

Darco submersible bottom suction high pressure pump


y y y y y y y y y

120 VAC - 1/2 HP - 50 PSI - 20 GPM nominal discharge capacity Plugged port for optional pressure relief valve For household water supply use or low volume irrigation Assembly mounts on 1 inch pitless adapter in manway Lift up to easily remove pump Includes 1" ss flex member Installation requires hole saw and grinder work on site Use float tree and level control float switch kits as needed Installation must comply with local plumbing codes

32

PVC float tree and level control float switch kits


y y y y y y y

Sliding adjustable float position design Includes 2 mounts with stainless steel hardware Used to control pumping functions - up or down Includes one 3 wire, 12 amp (non mercury) SP/DT switch 1" PVC drop pipe by others Installation must comply with local electrical codes Additional switch kits available

33

Alarm panel for high level or low level water volume alert
y y y y y y

120 VAC power required Sealed box mounts on post by tank or inside building Flashing red light and buzzer Alarm silence switch on outside surface of panel Includes one float tree and one universal float switch Field assembly required

34

Fiberglass "half round" deadman forms for on-site pouring


y y y y y y

12 feet long / may be sawed down for shorter applications Ships along side tank on trailer Reuseable if oiled before pouring concrete Follow Darco deadman size and rebar location details in manual Must be fully supported with compacted soil before pouring Use split cardboard caisson tubes when deadmen must be poured before tank delivery

35

Anchor strap and cable kits


y y y y y

Each kit contains 1 fiberglass strap with forged steel eyes or hooks at both ends Includes 2 Darco ratcheting strap tensioning tools (per tank) Includes 2 galvanized " steel connection cables and 6 clamps per strap assembly No turnbuckles are required Stainless cable and fabric straps are available upon request

36

Bonded 24" dia. bottom sump


y y y y y y

One piece - molded into tank 24" in diameter x 12" deep Suitable to locate submersible pumps up to 150 pounds Allows complete tank volume discharge through suction pipe Can incorporate an anti-vortex plate for NFPA suction hydrant compliance when needed Anti-vortex plate not included

37

Bolt-on 24" diameter bottom sump


y y y y

Allows complete tank volume water usage Often used for submersible or vertical turbine pumps Bolted design with 32" total depth below bottom of tank 24" inside diameter with tapered lower section

Writt

Pri qu t

u j tt g red f r t irt (30) days Back t p

ly.

fi erglass tanks | p lyet ylene tanks | p lyet ylene accessories

Darco Incorporated || 980 Darco Drive || P.O. Box 779 Bennett, CO 80102 || info@darcoinc.com or use our e-mail contact form

2000 to present .::. Darco Incorporated .::. all rights reserved .::. site by PrairieSkiesTech

Potrebbero piacerti anche