MICROLOGIC Trip Units

Making Circuit Breakers Smarter

The brains behind the new Square D line of low voltage MASTERPACT Power Circuit Breakers and POWER-ZONE 4 Switchgear is a new family of MICROLOGIC Trip Units. These interchangeable, microprocessorcontrolled, plug-in devices provide the next generation of protection, measurement and control functions, delivering not only greater electrical system safety but also improved system integration and coordination.

A Wide Range of Trip Unit Options

The upgraded MICROLOGIC Trip Unit family includes four models, with varying levels of functionality. The simplest units provide basic overcurrent protection including long-time and instantaneous adjustments for overloads and short circuits. More advanced units offer more sophisticated functions such as short-time and groundfault protection also allowing for zone selective interlocking with down-stream circuit breakers. They also incorporate a variety of communications options and POWERLOGIC Power Metering and monitoring capabilities right inside the circuit breaker. With the more advanced trip units, you can use a network to communicate with breakers, gather power information and energy usage patterns, monitor events and remotely control breakers for increased efficiency and savings. The breakers become part of an integrated, coordinated electrical system.

MICROLOGIC Trip Units

Upgrading Is Easy The new MICROLOGIC trip units make adding functionality, literally, a snap. They plug directly into MASTERPACT NW Power Circuit Breakers and can be installed quickly and easily on site (Refer to installation instructions for more details on installation). We also made the units completely interchangeable for added flexibility, to reduce your spare parts inventory and to protect against breaker obsolescence.

The new MICROLOGIC trip units make adding functionality, literally, a snap.

Choose the Model that Meets Your Needs

To offer you the maximum flexibility in product selection, the MICROLOGIC family consists of four models with progressively increasing levels of functionality.
MICROLOGIC 3.0 and 5.0

Basic circuit protection including long-time, instantaneous and optional short-time adjustments
MICROLOGIC 3.0A, 5.0A and 6.0A

Long-time, instantaneous and optional short-time adjustments Integrated ammeter and phase loading bar graph LED trip indication Zone selective interlocking with downstream breakers Optional ground-fault protection Optional MODBUS communications interface
MICROLOGIC 5.0P and 6.0P

Long-time, instantaneous and short-time adjustments Advanced relay protection (current imbalance, under/over voltage, etc.) Inverse Definite Minimum Time Lag (IdmtL) long-time delay curve shaping for improved coordination Basic power monitoring and metering functions Standard MODBUS communication interface compatible with POWERLOGIC installations GF alarm is standard on both 5.0P and 6.0P; 6.0P adds Ground-fault protection for equipment
MICROLOGIC 5.0H and 6.0H

All 5.0P and 6.0P series functions Enhanced monitoring and metering capabilities Basic power quality (harmonic) measurement Waveform capture

MICROLOGIC Trip Units


Standard Features True RMS Sensing LI LSI Instantaneous OFF LSIG/Ground-fault Trip Ground-fault Alarm (No Trip) (2)
Ground-fault Trip and Programmable Alarm (2)

Ammeter 3.0A X X X X X X X X X X X X 5.0A X 6.0A X 5.0P X X

Power 6.0P X X X X X X X X X

Harmonic 5.0H 6.0H X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X

3.0 X X

5.0

Adjustable Rating Plugs LED Long-time Pickup LED Trip Indication Digital Ammeter Phase Loading Bar Graph Zone Selective Interlocking (ZSI) Communications LCD Dot Matrix Display Advanced User Interface Protective Relay Functions Thermal Imaging Neutral Protection (1) Contact Wear Indication Waveform Capture Incremental Fine Tuning of Settings Selectable Long-time Delay Bands (IdmtL) Power Measurement Power Quality Measurements

X X

X X

X X X X X X O

X X X X X X O

X X X X X X O

X X X X X X X X X X

X X X X X X X X X X X X X X X X

X X X X X X

(1) Requires neutral current transformer X = Standard features (2) Requires M2C/M6C programmable contact module for the GF alarm

O = Available option

MICROLOGIC Trip Units are the intelligence behind a coordinated electrical distribution system that delivers improved operating efficiency and extended equipment life. For more information about the new MICROLOGIC family, call your local Square D sales office or nearby authorized distributor. You can also visit our web site at www.SquareD.com

Visit the Square D web site at www.SquareD.com

Order Number 0613HO9902R1/01