Typical applications:
- Pumps - Compressors - Hydraulics - Pneumatics - Water treatment
Dimensions (mm)
Ordering
Pressure connection
Pressure range 1) P e 0 -60 psi 0 - 100 psi 0 - 150 psi 0 - 200 psi 0 - 300 psi 0 - 500 psi 0 - 750 psi 0 - 1000 psi 0 - 1500 psi
Max. operation pressure 120 psi 300 psi 300 psi 750 psi 750 psi 1450 psi 2900 psi 2900 psi 2900 psi 5800 psi 8700 psi
Min. burst pressure 750 psi 750 psi 750 psi 1450 psi 1450 psi 12000 psi 12000 psi 12000 psi 12000 psi 12000 psi 23000 psi
Code no. 060G1140 060G1141 060G1142 060G1143 060G1144 060G1145 060G1146 060G1147 060G1148 060G1149 060G1150
/4-18 NPT
1)
Sealed gauge
August 1997
IK.22.F2.C2
Data sheet
Technical data
Performance
Accuracy Non-linearity (Best fit straight line) Hysteresis and repeatability Thermal zero point shift Thermal sensitivity (span) shift Response time Max. operating pressure Burst pressure 1% FS (typ.) / 2% FS (max.) < 0.5% FS 0.1% FS 0.2% FS/10K (typ.) 0.4% FS/10K (max.) 0.2% FS/10K (typ.) 0.4% FS/10K (max.) < 4 ms See ordering table, page 1 See ordering table, page 1
Electrical specifications
Rated output signal Supply voltage, Vsupply (polarity protected) Voltage dependency Current limitation Max. load, RL 4 to 20 mA 12.5 to 28 V d.c. < 0.2% FS/10 V 28 mA (typ.) Vsupply - 12.5 V ____________ [] RL 0.02 A
Environmental conditions
Operating temperature range Compensated temperature range Transport temperature range EMC - Emmission Electrostatic discharge EMC - Immunity RF field conducted burst surge Air 8 kV Contact 4 kV 10 V/m, 26 MHz - 1 GHz 3 Vrms, 150 kHz - 30 MHz 4 kV (CM), Clamp 1 kV (CM,DM) at Rg = 42 500 V, 50 Hz 20 g, 25 Hz - 2 kHz 7,5 g rms, 5 Hz - 1 kHz 500 g / 1 ms 30 to 80C 0 to 80C 50 to 85C EN 50081-1 EN 50082-1 (IEC 801-2) EN 50082-1 (IEC 801-2) EN 50082-1 (IEC 801-3) EN 50082-1 (IEC 801-6) EN 50082-1 (IEC 801-4) EN 50082-1 (IEC 801-5) > 100 M at 100 V d.c. SEN 361503 IEC 68-2-6 IEC 68-2-34, IEC 68-2-36 IEC 68-2-27 IEC 68-2-32 IP 65 - IEC 529
Transient Insulation resistance Mains frequency Vibration stability Shock resistance Enclosure Sinusoidal Random Shock Free fall
Mechanical characteristics
Pressure connection Electrical connection Wetted parts, material Housing material Weight G 1/4 A, ISO 228/1 DIN 43650 plug DIN 17440-1.4404 (AISI 316L) DIN 17440-1.4404 (AISI 316L) 0.2 kg
Description Pressure transmitter, type MBS 33 Pressure transmitters with sanitary process coupling, type MBS 33 and EMP 2 Pressure transmitter with ratiometric output signal, type MBS 32R Pressure transmitter with flush diaphragm, type MBS 4010 Pressure transmitter, type EMP Pressure transmitter, type MBS 33 M Pressure transmitter, block version, type MBS 5100 Pressure transmitters AKS 32 and AKS 33 Pressure transmitter with ratiometric output signal, type AKS 32 R Pressure transmitterAKS 3000
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.
Danfoss Inc. 7880 Tranmere Drive Mississauga, Ontario L5S 1L9, Canada Tel: 905-676-6000 Fax: 905-676-0279 2 IK.22.F2.C2
Danfoss Automatic Controls Division of Danfoss Inc. 7941 Corporate Drive Baltimore, Maryland 21236 Tel: 410-931-8250 Fax: 410-931-8256