Fourth generation design. Design based on worldwide communications, computer peripheral and office automation relay requirements. Offers excellent board space savings. Meets 2.5 kV Bellcore surge requirements. Terminal design based on Omron's successful G6S relay. Available in PCB through-hole, SMT gullwing and SMT inside-L terminals. Ambient temperature range of -40 to +85C. Complies with UL1950 Basic Insulation at 125 V. Available in 2.54 and 3.2 mm coil-contact terminal spacing versions. Available in single coil latching. RoHS Compliant.
Ordering Information
To Order: Select the part number and add the desired coil voltage rating (e.g., G6K-2F-DC5). Terminal Contact form Non-latching 2.54 mm spacing Gullwing Inside L PCB through-hole DPDT DPDT DPDT G6K-2F G6K-2G G6K-2P Model Non-latching 3.2 mm coil-contact terminal spacing G6K-2F-Y G6K-2G-Y G6K-2P-Y Single coil latching 3.2 mm coil-contact terminal spacing G6KU-2F-Y G6KU-2G-Y G6KU-2P-Y
Specifications
I Contact data
Load Rated load Contact material Max. carry current Max. operating voltage Max. operating current Max. switching capacity Min. permissible load Resistive load (cos=1) 0.3 A at 125 VAC 1 A at 30 VDC Ag (Au clad) 1A 125 VAC, 60 VDC 1A 37.5 VA, 30W 10 A at 10 mVDC
508
G6K- 2.5 mm coil-contact terminal spacing, standard, non-latching (G6K-2F, G6K-2G, G6K-2P) G6K- 3.2 mm coil-contact terminal spacing, non-latching (G6K-2F-Y, G6K-2G-Y, G6K-2P-Y)
Rated voltage (VDC) 3 4.5 5 6 9 12 24 Rated current (mA) 33.0 23.2 21.1 17.6 11.3 9.1 4.6 Coil resistance () 91 194 237 341 795 1,315 5,220 Pick-up voltage 80% max. Dropout voltage % of rated value 10% min. 150% max. (at 85C) Maximum voltage Power consumption (mW) 100 (approx.)
The rated current and coil resistance are measured at a coil temperature of 23C (73F) with a tolerance of 10%. The operating characteristics are measured at a coil temperature of 23C (73F) unless otherwise specified. Pick-up voltage is measured with no carry current across the contacts. Pick-up voltage will vary with temperature. Specifications subject to change without notice.
I Characteristics
Contact resistance (initial) Operate time (set time) Release time (reset time) Bounce time Insulation resistance Dielectric strength 100 m max. 3 ms max. 3 ms max. 3 ms max 1,000 M min. (at 500 VDC) 1,500 VAC for 1 minute between coil contacts 1,000 VAC for 1 minute between contacts of different poles 750 VAC for 1 minute between contacts of the same pole 2,500 V, 2x10 s (conforms to Bellcore specifications) between coil and contacts 1,500 V, 10x160 s (conforms to FCC Part 68) between contacts of different poles 1,500 V, 10x160 s (conforms to FCC Part 68) between contacts of the same pole Mechanical durability Malfunction durability Shock Ambient temperature Humidity Service life Mechanical Electrical Note: Data shown are of initial value. Mechanical durability Malfunction durability 10 to 55 Hz; 5.0 mm double amplitude 10 to 55 Hz; 3.3 mm double amplitude 1,000 m/s2, approx. 100G 750 m/s2, approx. 75G -40C to 85C (-40F to 185F) 35 to 85% RH 50,000,000 operations min. (at 36,000 operations per hour) 100,000 operations min. at rated load (at 1,800 operations per hour)
Vibration
G6K
509
I Characteristic data
Max. Switching Capacity Ambient Temperature vs. Maximum Coil Voltage Ambient Temperature vs. Pick-up and Dropout Voltage
High-frequency Characteristics
Isolation Insertion Loss VSWR and Return Loss
Frequency (MHz)
Frequency (MHz)
Isolation (dB)
Frequency (MHz)
510
I Approvals
UL (File No. E41515) / CSA (File No. LR24825)
Type G6K-2F G6K-2G G6K-2P1 G6K-2F-Y G6K-2G-Y G6K-2P-Y G6KU-2F-Y G6KU-2G-Y G6KU-2P-Y DPDT Contact form Coil rating 3 to 24 VDC Contact ratings 0.3 A, 125 VAC 0.5 A, 60 VDC 1 A, 30 VDC
Note: Complies with UL1950 Basic Insulation at 125 V (pollution degree 1 for internal spacings, pollution degree 2 for external spacings).
Dimensions
Unit: mm (inch)
I Relays
G6K-2F
10 0.2 (0.39) 6.5 0.2 (0.26) 0.3 (0.012)
0.5 (0.02)
7.8 (0.31)
G6K-2G
10 0.2 (0.39) 6.5 0.2 (0.26) 0.3 (0.012)
0.5 (0.02)
4.9 (0.19)
G6K
511
G6K-2P
10 0.2 (0.39) 6.5 +0.2 (0.26) 5 0.3 (0.20) 0.5 (0.02) 0.4 (0.016) R0.2 2.54 (0.10) 2.54 (0.10) 0.1 (0.003) 3.5 (0.14) 2.54 (0.10) 5.08 (0.20)
G6K-2F-Y
10 0.2 (0.39) 6.5 0.2 (0.26) 5.2 0.2 (0.20)
1.6 (0.06)
0.5 (0.02)
1.2 (0.04) 3.2 (0.12) 5.4 (0.21) 7.6 (0.30) 7.8 (0.31)
G6K-2G-Y
10 0.2 (0.39) 6.5 0.2 (0.26) 5.2 0.2 (0.20)
1.6 (0.06)
1.8 (0.07)
0.5 (0.02)
1.2 (0.04) 3.2 (0.12) 5.4 (0.21) 7.6 (0.30) 0.8 (0.03) 1.2 (0.04) 4.9 (0.19)
5.7 (0.22)
G6K-2P-Y
10 0.2 (0.39) 6.5 +0.2 (0.26)
5 (0.20) 3.5 0.1 (0.14) (0.003) 1.2 (0.04) 3.2 (0.12) 5.4 (0.21) 7.6 (0.30) 5.08 0.15 (0.20)
1.2 (0.05)
0.71 (0.03)
512
G6KU-2F-Y
10 0.2 (0.39) 6.5 0.2 (0.26) 5.2 0.2 (0.20)
1.6 (0.06)
0.5 (0.02)
7.8 (0.31)
G6KU-2G-Y
10 0.2 (0.39) 6.5 0.2 (0.26) 0.3 (0.012)
1.8 (0.07)
0.5 (0.02)
5.7 (0.22)
G6KU-2P-Y
10 0.2 (0.39) 6.5 +0.2 (0.26)
5 (0.20) 3.5 0.1 (0.14) (0.003) 1.2 (0.04) 3.2 (0.12) 5.4 (0.21) 7.6 (0.30) 5.08 0.15 (0.20)
1.2 (0.05)
0.71 (0.03)
G6K
513
I Accessories
Relays in tube packing are arranged so that the orientation mark of each Relay is on the left side. Be sure to reference Relay orientation when mounting the Relay to the PCB. Tube packing Tape packing Standard nomenclature When ordering, add "TR" before the rated coil voltage (e.g., G6K-2G-TR-DC5). Note: TR is not part of the relay model number and will not be marked on the relay. 50 pcs per anti-static tube 900 pcs per reel (see details below)
Pulling direction
2. Reel Dimensions
514
Precautions
I Correct Use
Handling
Do not unpack the relay until mounting it.
Soldering
Solder: JIS Z3282, H63A or equivalent Soldering temperature: Approx. 250C (260C if the DWS method is used) Soldering time: Approx. 5 s max. (approx. 2 s for the first time and approx. 3 s for the second time if the DWS method is used) Be sure to make a molten solder level adjustment so that the solder will not overflow on the PCB.
Coating
The Relay mounting on the PCB may be coated or washed but do not apply silicone coating or detergent containing silicone, otherwise the silicone coating or detergent may remain on the surface of the Relay.
PCB Mounting
Direction A: 1.96 N Direction B: 4.90 N Direction C: 1.96 N
If two or more Relays are closely mounted with the long sides of the Relays facing each other and soldering is performed with infrared radiation, the solder may not be properly exposed to the infrared rays. Be sure to keep the proper distance between adjacent Relays as shown below to insure formation of good solder joints.
G6K-2G
G6K-2F
G6K
515
Complete Terms and Conditions of Sale for product purchase and use are on Omrons website at www.components.omron.com under the About Us tab, in the Legal Matters section. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
OMRON ON-LINE
Global - http://www.omron.com USA - http://www.components.omron.com Canada - http://www.omron.ca Printed in USA
847-882-2288
Cat. No. JB301-E3-01 3/05
416-286-6465