2-Pipe Multi-System
3-Pipe Multi-System
Simultaneous Heating & Cooling
KX-2 systems are used extensively in offices, hotels, retail stores, fitness clubs, restaurants, and many other commercial applications. The simple pipework configuration allows easy installation, and discreet concealment of refrigerant and condensate piping. With 2-pipe systems there are no refrigerant distribution boxes, as all connections are made using branch pipe kits. Cassette and ducted internal units have condensate lift pumps, to overcome problems of routing of drain piping, allowing installation in most locations, without the need for additional pump kits. The outdoor unit is compact, the height has been reduced to 1450mm, and the access for routine service and maintenance is from the front only, allowing a number of units to be installed side by side in confined spaces. Pipe connections to the outdoor unit can be made from the front, back, right or bottom. The newly developed 570mm diameter sickle bladed fan reduces the outdoor sound level to 59dB, and the increased air volume allows operation in ambient temperatures down to -15C.
Two-PipeSystems
KX2 2-Pipe systems are applied to open plan areas, retail stores, or cellular offices, which would require heating or cooling during the same operational periods, e.g. offices which are all located on the same side of the building.
FDC Internal Location With planning restrictions and space limitations, it is often necessary to install a VRF unit within an enclosure inside the building. The angled fan arrangement allows high performance, low noise fans to be accomodated within the reduced depth of the unit casing, as well as providing the possibility of air discharge through a short duct addition.
FDC224 22.4kw Connectable units: 13 max FDC280 28.0kw Connectable units: 16 max
NEW
K-MAX Super VRF from 45kw-126kw Connectable units: 40 max
One
Three-PipeSystems
Flexible control with heating and cooling at any terminal unit simultaneously, with energy recovery between warm and cool areas. The KXR system provides the client with a fully flexible comfort control system, with all the benefits of energy efficiency and reduced running costs. It is ideal where there is mixed requirement for some areas to be cooled and others to be heated, e.g. north and south sides of a glass fronted building, or retail store, where concentrations of customers or lighting levels would dictate a combination of simultaneous cooling and heating. It can help with energy costs by utilising waste heat from office equipment in one area, and utilising this heat energy to provide heating in a cool area of the building. Generally, if there is no other form of heating in a building , the KXR 3-pipe system is more suitable than a 2-pipe system. It avoids conflict between the occupants as to which mode of operation, heating or cooling, takes priority. The Mitsubishi KXR offers different pipework distribution possibilities. All internal units are required to be connected to a refrigerant Distribution Controller, which enables the units to heat or cool. The KXR-system has both individual and combined Distribution Controllers, the latter allowing several internal units to be connected, each having independent control, but reducing the number of pipe joints required on site, resulting in lower installation costs.
5A/ph 5A/ph
340 361
NEW
FDC-16
KXR with Single Distribution Controllers
The maximum connectable number of internal units has now been increased to 16 (on 28KW model) and 13 (on 22.4KW model). This allows multiples of small internal units to be connected, ideal for small cellular offices or hotel rooms.
These new KXR models are compatible with the latest compact cassette/ducted internal unit, the FDTQ - see page 6 for details.
NEW
FDC-P for R407C
This new outdoor unit completes the comprehensive range of VRF multi systems available from MITSUBISHI. All units are factory processed, fully tested, and Quality Assured at the Nagoya factory in Japan.
KXR-16 with Four 4-way Distribution Controllers all internal units capable of simultaneous cooling or heating
Two
2-Pipe Super-VRF
Modular System Combination
K-MAX 448 K-MAX 500 K-MAX 560 K-MAX 672 K-MAX 728 K-MAX 784 K-MAX 840 K-MAX 896 K-MAX 952 K-MAX 1008 K-MAX 1064 K-MAX 1120
1 2
1 2 3
Three
Remote Control
RCD
Remote control for internal units, either individually, or as a group (up to 16). Temperature display. Programmable timer - 24 hour. Fan speed selection. Filter maintenance indication. Integral sensor (can be used as alternative to unit inbuilt sensor)
Return air temperature display. Cool / Heat Auto selection. Error message display. Check function for service engineer. Can be used as Master or Slave remote control. Control options and displays can be disabled, to provide simplified controller.
SCA-WTE
7 day programmable timer Three on/off times can be set for each day, to one minute timing. Automatic turn off can be programmed. Set programme can easily be overidden for one day if required. Time/day display.
Programme is memorised and restored after power interruption. Programmes can be selected for 16 groups when used with SLA-2AE Maximum 48 units can be controlled. Can be positioned and wired at any point on the 2-wire fuzzy logic control loop.
SLA-1E
Group operation on/off control, both Common fault indication of individual unit within Group. individual units, or complete group. Can be used with external time clock. Can be positioned and wired at any point on the 2-wire fuzzy logic Overides the individual unit Remote control loop. Controller on/off function. Power Source Kit with enclosure, for Can be used in conjunction with connection to mains power supply. SLA-2AE
Temperature, mode, and fan speed setting of individual units or Groups of units. Groups (up to 16) can be arranged in any combination of indoor units Heating/Cooling and Auto function included.
Error message code display and fault indication Can be used with external time clock for Group on/off control. Overides individual unit Remote Controller selection. Power Source Kit with enclosure, for connection to mains power supply.
Four
Wall controller option hard wired Reduced height slim construction Low profile attractive grey/white fascia panel Fresh air and branch duct facility Low noise 33dBA on smaller models New shape swing louvers for optimum control of air distribution Anti-smudge design of air discharge Fault diagnosis Condensate Lift Pump included Optional SPACE COLLAR for restricted ceiling voids
FDT 28 FDT 36 FDT 45 FDT 56 FDT 71 FDT 90 FDT 112 FDT 140
25 32 40 50 63 80 100 125
31 31 31 31 31 35 35 37
FDTS 45 FDTS 71
40 63
1ph/5A 1ph/5A
4.50 7.10
4.33 6.84
3.66 5.27
3.20 4.00
840 1080
1/4 3/8
3/8 5/8
194 194
194 194
23 30
Slim height construction - only 198mm Fresh air and branch duct facility Low noise 38dBA on smaller models Condensate Lift Pump included Fault diagnosis
Five
Fits 600 x 600 ceiling opening Wall controller option hard wired Compact construction Low profile attractive white fascia panel Fresh air duct facility Low noise 33dBA on smaller models Swing louvers for optimum control of air distribution Fascia panel - extra width option for access in solid ceilings Ducted horizontal air discharge possible Fault diagnosis Condensate Lift Pump included
FDQM-KX Ducted
FDQM-KX Ducted
Unit ref. Old ref. Power Supply Nom. Cooling KW 2.20 2.80 3.60 UK. Cooling KW 2.11 2.67 3.44 UK Sensible Cooling KW 1.94 2.42 3.01 Heating Heat pump KW 2.50 3.20 4.00 Air Volume max m3/h 420 420 420 Connection o.d. sizes liq. gas 1/4 1/4 1/4 1/2 1/2 1/2 Unit Dimensions mm H 250 250 250 W 570 570 570 D 565 565 565 Unit depth in ceiling mm 250 250 250 Weight KG FDQM 22 FDQM 28 FDQM 36 20 25 32 1ph/5A 1ph/5A 1ph/5A 20 20 20
Wall controller option hard wired Compact construction Duct connection - rectangular Fresh air duct facility Low noise 33dBA on smaller models Duct resistance 30 Pa Fault diagnosis Condensate Lift Pump included up to 600mm lift
Six
Wall controller option hard wired Fresh air facility Low noise levels Circular spigots for easy duct connection Return air filter not included High fan performance Fault diagnosis Condensate Lift Pump included
40 50 63 80 100 125
34 34 40 40 57
59
40 50 63 80 100 125
37 37 43 43 59 61
Wall controller option hard wired Bottom return air Fresh air and exhaust air duct facility Low noise 36dBA on smaller models Can be supplied with or without ceiling panel Condensate Lift Pump included Fault diagnosis
Seven
Wall controller option hard wired Attractive light beige casing Adjustable air louver for optimum air distribution Low noise - 37dBA on smaller models High cooling performance Fault diagnosis Condensate Lift Pump optional accessory with integral fail-safe protection
20 25 32 40 50 63
19 19 19 19 20 22
Eight
Wall controller option hard wired, can be fitted within top of unit if required Slim construction - only 225mm deep Low noise 33dBA on smaller models Fault diagnosis
25 40 63
32 32 40
25 40 50 63
25 25 25 32
Wall controller option hard wired Slim construction - only 225mm Low noise 36dBA on smaller models Easy access for installation and servicing Fault diagnosis
Nine
Wall controller option hard wired Low noise levels on smaller models Unit can be installed up to adjacent wall to conceal all pipe connections Adjustable air louver for optimum air distribution Return air filter included Can be partially recessed into ceiling if required Fault diagnosis
32 40 50 63 100 125
22 22 22 27 34 40
25 40 50 63 80 100 125
26 26 26 35 35 49 49
Wall controller option hard wired Ceiling panel included Fresh air and exhaust air duct facility Low noise 36dBA on smaller models All service access through ceiling panel Condensate Lift Pump included Fault diagnosis
Ten
3D Air Sales Ltd is the distributor in the UK and Eire of Mitsubishi Heavy Industries air conditioning and heat pump systems. The KX2 and KXR systems represent the latest technology of energy efficient multi systems for commercial applications. The advanced technology is manifested in a state-of-the-art automatic control system, constantly self adjusting to suit the varying needs of each individual area within the building, whilst providing the occupants with a stable and comfortable environment. It is important that the systems are configured and applied correctly. 3D technical and sales staff can assist with the selection of equipment, and provide layout diagrams and pipework schematics for consultants and contractors. Installation must be carried out by competent engineers, with every care being taken to ensure non-contamination of the refrigerant pipework. It is essential to purge pipework with dry nitrogen when making brazed joints. Mitsubishi Heavy Industries has a long established reputation of quality and reliability, with an extensive history of developing refrigeration and air conditioning products, electronic control systems, compressor technology, automotive air conditioning and applied equipment.