Unity Pro v4.1 - Compatibility rules Unity Pro and application version Version X.Y applications: application version corresponding to the processor chosen in the Unity Pro configuration screen (project creation step). Unity Pro V4.1 handles version levels: Premium/Quantum V2.00 (V2.21), V2.30, V2.40, V2.50, V2.60, V2.70; Modicon M340 V1.0, V2.0, V2.1 Unity Pro V4.0 handles version levels: Premium/Quantum V2.00 (V2.21), V2.30, V2.40, V2.50, V2.60; Modicon M340 V1.0, V2.0 Unity Pro V3.1 handles version levels: Premium/Quantum V2.00 (V2.21), V2.30, V2.40, V2.50; Safety Quantum V1.0; Modicon M340 V1.0 Unity Pro V3.0 handles: Premium/Quantum V2.00 (V2.21), V2.30, V2.40; Modicon M340 V1.0 Unity Pro V2.3 SP1 handles: Premium/Quantum V2.00 (V2.21) and V2.30 Unity Pro V2.2 handles: Premium/Quantum V2.00 (V2.21) and V2.00 (V2.21) MFB if MFB (Motion Function Block) option was set up with Unity Pro V2.2 Unity Pro V2.1 handles: Premium/Quantum V2.00 Unity Pro V2.0 handles: Premium/Quantum V2.00
2.1. Table 1 XEF Files on the PC Open with Unity Pro V2.0 YES (1) Open with Unity Pro V2.1 YES (1) Open with Unity Pro V2.2 YES (1) Open with Unity Pro V2.3 SP1 YES Open with Unity Pro V3.0 YES Open with Unity Pro V3.1 YES Open with Unity Pro V4.0 YES Open with Unity Pro V4.1 YES
Premium / Quantum V2.00 application* Premium / Quantum V2.30 application (1) Premium / Quantum V2.40 application Premium V2.50 application Premium / Quantum V2.60 application Premium / Quantum V2.70 application Modicon M340 V1.0 application Modicon M340 V2.0 application Modicon M340 V2.1 application Quantum safety V1.0 application Quantum safety V2.0 application
NO
NO
NO
YES
YES
YES
YES
YES
NO
NO
NO
NO
YES
YES
YES
YES
NO
NO
NO
NO
NO
YES
YES
YES
NO
NO
NO
NO
NO
NO
YES
YES
NO
NO
NO
NO
NO
NO
NO
YES
NO
NO
NO
NO
YES
YES
YES
YES
NO
NO
NO
NO
NO
NO
YES
YES
NO
NO
NO
NO
NO
NO
NO
YES
NA
NA
NA
NA
NA
YES
NA
YES
NA
NA
NA
NA
NA
NO
NA
YES
NA: Not Applicable (Quantum Safety only exists for Unity Pro V3.1 & V4.1) * Application version corresponds to the choice of PLC in the Unity Pro configuration screen during the creation of a project (V2.00, V2.30 ) See Unity Pro, application and PLC OS compatibility (Table 7). Restriction: (1) If there are MFBs in the application, these ones are not usable; errors are generated during the build phase, except for Unity Pro V2.2 with MFB option.
Ttulo Documento
2.2. Table 2 STA Files on the PC Open with Unity Pro V2.0 YES(1) NO NO NO Open with Unity Pro V2.1 YES (2) NO NO NO Open with Unity Pro V2.2 YES (2) NO NO NO Open with Unity Pro V2.3 SP1 YES (3) YES NO NO Open with Unity Pro V3.0 YES YES YES NO Open with Unity Pro V3.1 YES YES YES YES Open with Unity Pro V4.0 YES YES YES YES With Unity Pro V4.1 YES YES YES YES
Premium / Quantum V2.00 application Premium / Quantum V2.30 application Premium / Quantum V2.40 application Premium V2.50 application Premium / Quantum V2.60 application Premium / Quantum V2.70 application Modicon M340 V1.0 application Modicon M340 V2.0 application Modicon M340 V2.1 application Quantum safety V1.0 application Quantum safety V2.0 application
NO
NO
NO
NO
NO
NO
YES
YES
NO
NO
NO
NO
NO
NO
NO
YES
NO NO
NO NO
NO NO
NO NO
YES NO
YES NO
YES YES
YES YES
NO
NO
NO
NO
NO
NO
NO
YES
NA NA
NA NA
NA NA
NA NA
NA NA
YES NO
NA NA
YES YES
NA: Not Applicable (Quantum Safety only exists for Unity Pro V3.1 & V4.1) Restrictions: (1) Unity Pro V2.0 does not allow to open STA other than those generated with Unity Pro V2.0 (2) When application generated doesnt contain MFB functions, except for Unity Pro V2.2 with MFB option (3) When application contains writing on read only variable, the STA is not opened, the corrections must be done before creating the STA 2.3. Table 3: STU Files on PC Open with Unity Pro V2.0 Open with Unity Pro V2.1 Open with Unity Pro V2.2 Open with Unity Pro V2.3 SP1 Open with Unity Pro V3.0 Open with Unity Pro V3.1 Open with Unity Pro V4.0 With Unity Pro V4.1
STU Files on PC
Application generated with Unity Pro V2.0 Application generated with Unity Pro V2.1 Application generated with Unity Pro V2.2 Application generated with Unity Pro V2.3 SP1 Application generated with Unity Pro V3.0
YES
NO
NO
NO
NO
NO
NO
NO
NO
YES
YES
NO
NO
NO
NO
NO
NO
NO
YES (1)
NO
NO
NO
NO
NO
NO
NO
NO
YES
NO
NO
NO
NO
NO
NO
NO
NO
YES
NO
NO
NO
Ttulo Documento
NO
NO
NO
NO
NO
YES
NO
NO
NO
NO
NO
NO
NO
NO
YES
NO
NO
NO
NO
NO
NO
NO
NO
YES
Restriction: (1) When application contains MFB it can be opened only when MFB option is set up with Unity Pro V2.2 2.4. Table 4: PLC => PC Transfer With Unity Pro V2.0 With Unity Pro V2.1 With Unity Pro V2.2 With Unity Pro V2.3 SP1 With Unity Pro V3.0 With Unity Pro V3.1 With Unity Pro V4.0 With Unity Pro V4.1
Premium / Quantum V2.00 application Premium / Quantum V2.30 application Premium / Quantum V2.40 application Premium V2.50 application Premium / Quantum V2.60 application Premium / Quantum V2.70 application Modicon M340 V1.0 application Modicon M340 V2.0 application Modicon M340 V2.1 application Quantum safety V1.0 application Quantum safety V2.0 application
YES (1)
YES (1)
YES (2)
YES
YES
YES
YES
YES
NO
NO
NO
YES
YES
YES
YES
YES
NO
NO
NO
NO
YES
YES
YES
YES
NO
NO
NO
NO
NO
YES
YES
YES
NO
NO
NO
NO
NO
NO
YES
YES
NO
NO
NO
NO
NO
NO
NO
YES
NO NO
NO NO
NO NO
NO NO
YES NO
YES NO
YES YES
YES YES
NO
NO
NO
NO
NO
NO
NO
YES
NA NA
NA NA
NA NA
NA NA
NA NA
YES NO
NA NA
YES YES
NA: Not Applicable (Quantum Safety only exists for Unity Pro V3.1 & V4.1) Restrictions: (1) Transfer not possible when application contains MFB (2) Exception: the application switches to "V2.00 MFB Application" level when MFB option is set up with Unity Pro V2.2 2.5. Table 5: PC => PLC Transfer With Unity Pro V2.0 With Unity Pro V2.1 With Unity Pro V2.2 With Unity Pro V2.3 SP1 With Unity Pro V3.0 With Unity Pro V3.1 With Unity Pro V4.0 With Unity Pro V4.1
YES
YES
YES
YES
YES
YES
YES
YES
Ttulo Documento
Premium / Quantum V2.30 application Premium / Quantum V2.40 application Premium V2.50 application Premium / Quantum V2.60 application Premium / Quantum V2.70 application Modicon M340 V1.0 application Modicon M340 V2.0 application Modicon M340 V2.1 application Quantum safety V1.0 application Quantum safety V2.0 application
NO
NO
NO
YES
YES
YES
YES
YES
NO
NO
NO
NO
YES
YES
YES
YES
NO
NO
NO
NO
NO
YES
YES
YES
NO
NO
NO
NO
NO
NO
YES
YES
NO
NO
NO
NO
NO
NO
NO
YES
NO
NO
NO
NO
YES
YES
YES
YES
NO
NO
NO
NO
NO
NO
YES
YES
NO
NO
NO
NO
NO
NO
NO
YES
NA
NA
NA
NA
NA
YES
NA
YES
NA
NA
NA
NA
NA
NO
NA
YES
NA: Not Applicable (Quantum Safety only exists for Unity Pro V3.1 & V4.1) Restriction: (1) See application compatibility with the OS table
2.6. Table 6: Online modification With Unity Pro V2.0 With Unity Pro V2.1 With Unity Pro V2.2 With Unity Pro V2.3SP1 With Unity Pro V3.0 With Unity Pro V3.1 With Unity Pro V4.0 With Unity Pro V4.1
Online modification
Premium / Quantum V2.00 application Premium / Quantum V2.30 application Premium / Quantum V2.40 application Premium V2.50 application Premium / Quantum V2.60 application Premium / Quantum V2.70 application Modicon M340 V1.0 application
YES
YES
YES (1)
YES (2)
YES (2)
YES (2)
YES
YES
NO
NO
NO
YES
YES
YES
YES
YES
NO
NO
NO
NO
YES
YES
YES
YES
NO
NO
NO
NO
NO
YES
YES
YES
NO
NO
NO
NO
NO
NO
YES
YES
NO
NO
NO
NO
NO
NO
NO
YES
NO
NO
NO
NO
YES
YES
YES
YES
Ttulo Documento
Modicon M340 V2.0 application Modicon M340 V2.1 application Quantum safety V1.0 application Quantum safety V2.0 application
NO
NO
NO
NO
NO
NO
YES
YES
NO
NO
NO
NO
NO
NO
NO
YES
NA
NA
NA
NA
NA
YES
NA
YES
NA
NA
NA
NA
NA
NO
NA
YES
NA: Not Applicable (Quantum Safety only exists for Unity Pro V3.1 & V4.1) Restrictions: (1) Exception: When MFB option is set up with Unity Pro V2.00 the application switches to "V2.00 MFB" level (2) Adding a new EFB Type needs to update the library in the project (rebuild all) 2.7. Table 7 Unity Pro application and PLC OS compatibility Unity Pro, application and PLC OS compatibility PREMIUM minimum OS version 2.70 2.60 2.50 (2) Unity Pro V4.1 2.40 2.30 2.21 (1) 2.00 MFB 2.00 PREMIUM QUANTUM minimum OS version 2.70 2.60 x 2.40 2.30 x x 2.00 QUANTUM QUANTUM SAFETY minimum OS version 2.00 x 1.00 x x x x x QUANTUM SAFETY Quantum Safety Not supported x x x x x x QUANTUM SAFETY 1.00 x x x x x QUANTUM SAFETY x x x 1.00 x x x 1.00 x x x x M340 2.00 x 1.00 x x x x M340 M340 minimum OS Version 2.10 2.00 x 1.00 x x x x M340
2.60 2.50 (2) Unity Pro V4.0 2.40 2.30 2.21 (1) 2.00 MFB 2.00 PREMIUM 2.50 (2) 2.40 Unity Pro V3.1 2.30 2.21 (1) 2.00 MFB 2.00 PREMIUM Unity Pro V3.0 2.40 2.30 2.21 (1)
2.60 x 2.40 2.30 x x 2.00 QUANTUM x 2.40 2.30 x x 2.00 QUANTUM 2.40 2.30 x
Ttulo Documento
The OS version corresponds to the minimum version required to execute a functional level of the application. Higher OS versions ensure compatibility with existing applications (for example: an application version V2.00 generated by Unity Pro V2.20 can be executed by a PLC V2.30). (1) (2) Only TSX P 57 5634 M. Only TSX H57 24 M and TSX H57 44 M
Ttulo Documento