HOOKUP & PROGRAMMING BOOK

Document 10107/15.08.00 / Version 1

Cerber C41V1 Cerber C41V4


4 zone + 1 special zone control panels with built-in vocal comunicator

Cerber C41V1/Cerber C41V4


HOOKUP INSTALLATION & PROGRAMMING BOOK

Table of Contents
INTRODUCTION ........................................................................................................... 3
Technical specifications ...................................................................................................... 4 Installing and commissioning ............................................................................................... 5 Connectors ........................................................................................................................... 7

OPERATING ................................................................................................................. 8

Operating Codes .................................................................................................................. 8 Installer's Programming Code ............................................................................................... 9 Arming .................................................................................................................................. 9 Other Arming Modes .......................................................................................................... 10 QUICK Arming .............................................................................................................. 10 INSTANT STAY Arming ............................................................................................. 10 STAY Arming ............................................................................................................. 10 Disarming ............................................................................................................................ 11 Other operating commands ............................................................................................... 11 Zone bypassing ........................................................................................................... 11 System State Display .................................................................................................. 12 Alarm Memory Display ................................................................................................. 12 Door Chime On/Off ...................................................................................................... 13 Program/Modify User Codes ....................................................................................... 13 Changing or Adding a Code .................................................................................. 14 Erasing a Code ...................................................................................................... 14 Dialing Stop ......................................................................................................................... 14

VOCAL MESSAGES RECORDING/VERIFICATION ................................................... 14 SYSTEM PARAMETER PROGRAMMING ................................................................. 16


Sections [01..07] - First ... Seventh Phone number .......................................................... 17 Section [08] - Message Duration/Dialing Attempts Number .............................................. 17 Section [09] - Zone Definitions .......................................................................................... 18 Section [10] - Key Zone Definitions ................................................................................... 20 Section [11] - System Times .............................................................................................. 20 Section [12] - Installer's Code Changing ............................................................................ 21 Section [13] - Programmable Output Options for PGM1, PGM2 ........................................ 21 Section [14] - Dialing Mode/Message Selection ................................................................ 22

PROGRAMMING FORM ............................................................................................ 24 Warning Limitations of this Alarm System .......................................................... 27


2

Cerber C41V1/Cerber C41V4


HOOKUP INSTALLATION & PROGRAMMING BOOK

INTRODUCTION
Cerber C41V1/Cerber C41V4 are keypad operated burglary systems, with built-in telephone dialer, alarm memory and 4 access codes. Only one 30 second vocal message is available for Cerber C41V1 control panel. Four vocal messages, approx. 15 seconds each, are available for Cerber C41V4 control panel. The system facilities are keypad programmable. The central unit is RISC microprocessor designed. The electric scheme includes an EEPROM memory. Thus, the programmed parameters are retained even after all power was removed from the control panel. 4 End-of-Line Resistor supervised zones; All zones are programmable as Entry/Exit, Instant, Follower or 24 hour; One Keyswitch/Tamper zone; Keypad programming; Master code and 3 user codes, all programmable; Optional Ambush code (code 4); Quick arming, Stay arming, Instant stay arming; Optional Forced arming for Entry/Exit and Follower zones; Optional zone bypassing; Programmable Chime function; Programmable siren alarm type: Steady, Pulse or Silent; Programmable Entry delay, Exit delay; Optional Keyswitch arming/disarming; 9 options for 2 programmable outputs which are: Latch alarm, Arming/ Disarming, Entry delay, Exit delay, System Trouble, Steady siren, Pulsing siren, Silent alarm or Panic; First 9 alarm events which have occurred since the last arming are displayed on keypad; 7 programmable phone numbers for one message transmission (Cerber C41V1 control panel), respectively 4 messages (Cerber C41V4 control panel);
3

FEATURES:

Cerber C41V1/Cerber C41V4


HOOKUP INSTALLATION & PROGRAMMING BOOK

Message duration and dialing attempts' number are programmable; Monitoring system state, battery state and AC power; EEPROM memory retains the programmed configuration even after all power was removed from the control panel; Up to 4 keypads, 4 wire linked; Keypad tamper using microswitch; Individual state LEDs for each zone, indicating the alarm state; System state LEDs (READY, SYSTEM, ARMED).

TECHNICAL SPECIFICATIONS:
Power 12V/4Ah battery; 50mA stand-by current; typical 500mA power output on AUX power supply source

Inputs 4 fully programmable 2K2 EOL zones on board; 1 Keyswitch/tamper 2K2 EOL zones on board.

Outputs 2 "open-collector" outputs with negative trigger (NPN), max. 50mA;

1 "open-collector" siren output with positive trigger (PNP), typically 1A.

Cerber C41V1/Cerber C41V4


HOOKUP INSTALLATION & PROGRAMMING BOOK

INSTALLING AND COMMISSIONING PANEL MOUNTING


Select a dry location close to an unswitched AC source allowing ground connection. If the system also sends vocal messages, the location must be close to a telephone dose. Remove the printed circuit board and mount the cabinet securely to the wall using 4 screws. Mount the PCB into the cabinet. Pull all cables into the cabinet and prepare them for connection.

KEYPAD MOUNTING
The keypad should be located close to the designed Entry/Exit door and mounted at a convenient height for all users. Disassemble the keypad and mount the backplate on the wall. Pull the keypad wiring inside the keypad and prepare it for connection.

WIRING
NOTE: Complete all wiring to the control panel before applying it to battery or AC power. Wiring should be made according to one of the next diagrams, depending on the selected type: Cerber C41V1 or Cerber C41V4.

Cerber C41V1/Cerber C41V4


HOOKUP INSTALLATION & PROGRAMMING BOOK

Cerber C41V1 control panel

PLAY RECORD

F2

F1
SIREN 1.6A

AUX . 6A 1.

MIC

DIF

L IN E P HON E
+

SIRE N O U TP UT M AX 1A RE SISTO R NO T E P O L A R IT Y
GRN YEL EOL 2K2

RE SISTO R
EOL 2K2

RE D

B LA CK

1 2 V/4 A h B AT TE RY

G ND +1 2V d c

KE

AD YP
R ETU RN K EY N .C .

RE SISTO R
EOL 2K2

Cerber C41V4 control panel


RECORD M1 M2 M3 M4 F2
AUX 1,6A

F1
SIREN 1,6A

R EC

MIC

DIF

L IN E P HON E
+

SIRE N O U TP UT M AX 1A NO T E P O L A R IT Y
GRN YEL

RE SISTO R
EOL 2K2

RE SISTO R
EOL 2K2

RE D

B LA CK

G ND
BATERIE 12V/4Ah

+1 2V d c

KE

AD YP
R ETU RN K EY N .C .

RE SISTO R
EOL 2K2

BUSY

Cerber C41V1/Cerber C41V4


HOOKUP INSTALLATION & PROGRAMMING BOOK

CONNECTORS
The following connectors are located on the PCB panel : AUX - , AUX + Connectors for auxiliary power supply. These terminals supply power for keypads, PIR detectors and other active devices in the system. The maximum load on these terminals cannot exceed 500mA. Observe polarity! YEL, GRN Keypad communication. PGM 1, PGM 2 Programmable "open collector" outputs with negative trigger. The maximum load on this terminals cannot exceed 100mA. BELL +, BELL Siren output. "BELL+" is a positive trigger output (PNP). The maximum load on these terminals cannot exceed 1A. Observe polarity! Z1, COM, Z2, Z3, COM, Z4 Terminals for fully programmable zones. If not used, the terminals will be closed with a 2K2 EOL resistor. KEY Terminals for special Keyswitch/Tamper zones. If not used, the terminals will be closed with a 2K2 EOL resistor SET Phone set. LINE Phone line. DIF These terminals are used to connect a mini speaker in case of one's wish to listen to the recorded messages.

Cerber C41V1/Cerber C41V4


HOOKUP INSTALLATION & PROGRAMMING BOOK

COMMISSIONING
When finishing connections, first reset the system following the procedure described bellow. Reset to Default 1. Disconnect power, both batteries and AC power. 2. Connect jumper JP10 (RESET) on PCB. 3. Power the panel and wait for 2 seconds.. 4. If the system was reset to default, zone LEDs will blink successively, and the green READY LED will be lit. 5. Disconnect power, both batteries and AC power. 6. Take jumper JP10 off (RESET) PCB. 7. Power the panel. From now on, the system parameters are set to default and the system is disarmed.

OPERATION
Zone LEDs READY LED SYSTEM LED ARMED LED

System operation is done using the keypad and LEDs' indications. The keypad has 4 zone LEDs and 3 state LEDs: READY, SYSTEM, ARMED. LEDs' indications will be detailed throughout this manual.

OPERATING CODES
There are 4 programmable operating codes in the system. Code 1- Master Code programmed with "1234" value by default. Using the Master code one can operate the system and program the other user codes. Code 4 - "Ambush Code", not programmed by default. If the panel is connected to the phone line, when disarming - using this particular code - the panel will transmit a phone message to Cerber C41V1 control panel.
8

Cerber C41V1/Cerber C41V4


HOOKUP INSTALLATION & PROGRAMMING BOOK

For Cerber C41V4 control panel, using the Ambush code when disarming, the panel will transmit a special phone message meaning the system was disarmed under threat. Code modifying , including Master code, is made by [*][7][Master Code] command.

INSTALLER'S CODE
The default Installer's Code is 0269. This code achieves parameter programming by [*][8][Installer's code] command. The installer should change this code after mounting the system!

ARMING
Before arming the system, make sure that all protected doors and windows have been closed. If the SYSTEM LED is lit, check the following: - the alarm memory ([*][5] command). If there are alarms in the memory, it will be cleared when arming the system. - bypassed zones ([*][3] [Access code] command). Ensure that each zone displayed as being bypassed is intentionally bypassed. - system trouble ([*][4] command). If there are troubles with the battery or the AC power, fix them before arming. If "READY" LED is not lit, then one or more zones are open. One cannot arm the system if the system is not ready meaning that "READY" LED should be lit. To arm the system, introduce a 4 digit access code. When pressing each key, the keypad buzzer will sound a short beep. After pressing the access code, the "ARMED" LED will turn on and the keypad buzzer will sound 6 beeps. If the access code is not correct, the keypad buzzer will sound a long beep. Press the [#] key and then press the access code again. After pressing the access code and the "ARMED" LED was lit, exit the protected area through the Entry/Exit zone, before the Exit time was over. After the Exit time was over, all LEDs will be off, except the "ARMED" LED. The default Exit time is 120 seconds.

Cerber C41V1/Cerber C41V4


HOOKUP INSTALLATION & PROGRAMMING BOOK

OTHER ARMING MODES


QUICK ARMING [*] [0] This function will be used by someone who doesn't own an access code. Arming will be made by pressing the sequence [*][0]. Next, the user should leave the protected area before Exit time was over. After the Exit time was over, the whole system is armed and the "ARMED" LED will stay lit. INSTANT STAY ARMING [*] [1] [ACCESS CODE] This arming mode is used for perimeter protection. Thus, the user can stay inside the protected area (i.e.: arming the panel at night while staying home). After pressing the access code, the system automatically bypasses zones defined with "STAY" attribute. That is why the yellow "SYSTEM" LED will be lit. After the Exit time, all the Delayed zones will become Instant and they will trigger alarm the very moment they are opened. The red "ARMED" LED will blink indicating that the Delayed zones are Instant now. STAY ARMING [*] [2] [ACCESS CODE] This arming mode is also used for perimeter protection. This time the user also stays inside the protected area, but is allowed access through the Delayed zones. After pressing the access code the system automatically bypasses the zones defined with "STAY" attribute. That is why the yellow "SYSTEM" LED will be lit. After the Exit time was over, the whole system is armed and the "ARMED" LED will stay lit. NOTE: The Entry/Exit and the Follower zones can be programmed for Forced arming. That means these zones will be bypassed until their closing, after the Exit time was over. The Forced arming option is useful if, for example, going out of the system is done through a door with magnetic contact, which is connected to an Entry/ Exit zone. At the same time the door is supervised by a PIR detector, connected to a Follower zone. If the Exit time is shorter than PIR detector stabilization time, then the 2 zones will be programmed with Forced arming
10

Cerber C41V1/Cerber C41V4


HOOKUP INSTALLATION & PROGRAMMING BOOK

in order to be bypassed when arming.So, bypassing cancellation will be done when the zones are closed (that is when closing the door and leaving the protected area).

DISARMING
One can only enter the protected area through an Entry/Exit zone. When opening this zone, Entry time will begin counting. During Entry time keypad buzzer will sound a continuous beep indicating that the system should be disarmed. Press one of the access codes. If wrong press [#] key and press the code again. The "ARMED" LED will turn off and so will the buzzer. If the system is not disarmed during Entry time, the panel will alarm. To modify the Entry time see PROGRAMMING chapter, section 11.

OTHER OPERATING COMMANDS


ZONE BYPASSING [*] [3] [ACCESS CODE] Zone bypassing can only be done when the system is disarmed. The initiating devices from a bypassed zone will not be considered by the panel. Zone bypassing is used when access is needed in that particular zone even if the system is armed. Zone bypassing is also used when some initiating devices or wires are damaged and restoring is not immediately possible . Arming can be done with one or more bypassed zones, even if these ones are open. While the system is disarmed, press [*] [3] [User code] to display the bypassed zones. The "SYSTEM" LED will blink and the corresponding zone LEDs will be lit. To bypass a zone press the corresponding digit and the corresponding LED will turn ON. To cancel a zone bypassing press the corresponding digit, and the corresponding LED will turn OFF. Exit bypassing mode by pressing [#]. NOTE: When disarming the system, the bypassed zones will be cleared.

11

Cerber C41V1/Cerber C41V4


HOOKUP INSTALLATION & PROGRAMMING BOOK

SYSTEM STATE DISPLAY [*] [4] The alarm system is monitoring some trouble conditions. If one of these conditions occurs, the "SYSTEM" LED will turn ON. To display these conditions press [*] [4]. The conditions will be displayed on zone LEDs as follows: Zone 1 LED Low Battery: if the battery is disconnected or LOW, this LED is lit. The LED will turn OFF in 8 seconds after restoring the battery trouble. Zone 2 LED AC Power Loss: if AC power is OFF or the transformer is burnt this LED is lit. The LED is also lit if AC power circuit fuse is burnt. The LED will turn OFF instantly after restoring AC power trouble. To exit this mode press [#] key. ALARM MEMORY DISPLAY [*] [5] The alarms produced while last arming are memorized. To display the alarmed zones press [*] [5]. "SYSTEM" LED will blink and so will the LEDs of the alarmed zones. One can press the keys from 1 to 9 in order to visualize the first 9 alarm events during the last arming of the panel. Pressing the key [1] the first zone alarmed will be shown , while pressing the key [9] the latest alarmed zone will be shown. Pressing the key [0] one can see all the alarmed zones simultaneously. All the corresponding zone LEDs will blink. To exit this display mode press [#] key. The alarm memory will clear while arming the panel again . DOOR CHIME ON/OFF [*] [6] The Door Chime feature makes the keypad buzzer to sound 6 short beeps whenever a delayed zone is activated. The feature is useful if the Delayed doors are out of view and the user desires an indication of when the door zones are opened.

12

Cerber C41V1/Cerber C41V4


HOOKUP INSTALLATION & PROGRAMMING BOOK

The Door Chime feature works only if the the system is disarmed. The feature may only be turned on/off also while the system is disarmed. To turn the feature on/off enter [*] [6] command. If the feature is being turned ON, the keypad buzzer will beep 3 times. If the feature is being turned OFF, the keypad buzzer will sound only one long beep. PROGRAM/MODIFY USER CODES [*] [7] [MASTER CODE] The [*] [7] [Master Code] command allows the user to modify all user codes but the Installer's Code. Enter [*] [7] [Master Code] The LEDs READY, ARMED and SYSTEM will blink. The lit zone LEDs will indicate which codes are programmed. By default, zone 1 LED will be ON indicating the Master code is only pre-programmed (Master code is code 1). From this moment on the codes are to be modified as follows: Changing or Adding a Code In order to change or add the 1 to 4 access codes, enter the number of the code to be changed/added. The corresponding zone LED will blink and the keypad buzzer will sound 3 beeps. Enter the new access code (4 digits). Do not press [*] while entering the code. After introducing the code, the keypad buzzer will sound 6 beeps and the corresponding zone LED will be ON. To edit another code, key another order number in and replay the procedure. Thus, all the desired codes will be changed. Erasing a Code After introducing the number of the code to be erased, the corresponding zone LED will blink and the keypad buzzer will sound 3 beeps. To erase the code press [****]. NOTE: Do not erase Master Code! If, by mistake the Mater Code is erased, reset system programming to the factory default settings. (see Commissioning). During the Program/Modify User code mode, "READY", "SYSTEM" and "ARMED" LEDs will blink continuously and zone LEDs will indicate:
13

Cerber C41V1/Cerber C41V4


HOOKUP INSTALLATION & PROGRAMMING BOOK

Zone LED

The access code is:

OFF not programmed ON programmed blinking programming in progress After making all the desired changes, exit this mode by pressing [#] key. DIALING STOP [*] [9] [MASTER CODE] Dialing stop can only be done when the system is disarmed. Therefore, if an alarm occurs in armed mode and the dialer starts phone communication,in order to stop dialing enter a valid user code for disarming, then enter the sequence [*] [9] [Master Code].

VOCAL MESSAGE RECORDING/CHECKING CERBER C41V1 CONTROL PANEL


For vocal message recording follow the procedure described bellow: 1. Open the control panel cover. 2. Keep RECORD button pressed, placed top-right on the PCB. 3. After the red LED turned ON, holding RECORD button pressed, say the message directly into the microphone. The message must not exceed 30 seconds. NOTE: If the message exceeds 30 seconds, the LED turns OFF and the recording is automatically stopped. In this case, shorten the message and repeat the recording. 4. To stop the recording, release RECORD button. For local checking of recorded vocal messages follow the procedure described bellow: 1. Connect a temporary mini-speaker (min. 8ohm impedance) to the DIF terminals. 2. Press PLAY button, placed near the RECORD button, and listen to the message. 3. Disconnect the speaker. 4. Close the control panel cover.
14

Cerber C41V1/Cerber C41V4


HOOKUP INSTALLATION & PROGRAMMING BOOK

CERBER C41V4 CONTROL PANEL (4 VOICE MESSAGES)


For vocal messages recording follow the procedure described bellow: 1. Open the control panel cover. 2. Connect jumper REC on PCB. The green "RECORD" LED will turn ON. 3. Record the first message keeping M1button pressed . 4. After the red BUSY LED turned ON, keeping M1 button pressed, say the message directly into the microphone. The message does not have to exceed 15 seconds. NOTE: If the message exceeds 15 seconds, the BUSY LED turns OFF and the recording will be automatically stopped. In this case, shorten the message and repeat the recording. 5. To stop the recording, release M1 button. 6. To record the messages 2, 3 and 4, repeat steps 3 and 4 using buttons M2, M3 and M4, respectively. 7. Disconnect REC jumper . Each event is assigned a certain message as follows: Message 1 - One of zones 1-4 is activated Message 2 - Panic from the keypad Message 3 - AC Loss Message 4 - Ambush condition For local checking of recorded vocal messages follow the procedure described bellow: 1. Connect a temporary mini-speaker (min. 8Ohm impedance) to the DIF terminals. 2. Press one of M1-M4 buttons and listen to the respective message. BUSY LED is ON during the message playback. 3. Disconnect the speaker. 4. Close the control panel cover.

15

Cerber C41V1/Cerber C41V4


HOOKUP INSTALLATION & PROGRAMMING BOOK

SYSTEM PARAMETER PROGRAMMING


ENTERING THE PROGRAMMING MODE OF SYSTEM PARAMETERS [ * ] [ 8 ] [INSTALLER'S CODE] Entering the programming mode of system parameters is achieved by [*][8][Installer's Code] command, only in disarmed mode. The system programming options are explained bellow. The default Installer's Code is [0269] and it is strongly recommended to be changed after installing the alarm system. After pressing [*][8][Installer's Code], the keypad buzzer will sound 3 beeps, and the LEDs will display as follows: LED LED STATE

READY OFF SYSTEM Blinking ARMED ON Zone LEDs OFF Now you have just entered the system parameter programming mode. To leave the programming mode press [#] key. System parameters are grouped in sections counted from 01 to 14. To enter each section press the 2 corresponding digits. After entering the 2 digits, the keypad buzzer will sound 3 beeps an the LEDs will display as follows: LED LED STATE

READY ON SYSTEM Blinking ARMED ON Zone LEDs OFF This moment you are inside the chosen section. To leave the section press [#] key. Certain programming entries may require entry of data in HEX. To enter data in HEX format, first press the [*] key followed by a number according to the data inthe table bellow:

16

Cerber C41V1/Cerber C41V4


HOOKUP INSTALLATION & PROGRAMMING BOOK

HEX number A Enter [*][0] B Enter [*][1] C Enter [*][2] D Enter [*][3] E Enter [*][4] F Enter [*][5] Note that after pressing the [*] key, READY LED will blink and after entering the decimal digit , the LED will stay lit.

PROGRAMMING SECTIONS
SECTIONS [01..07] - FIRST ... SEVENTH PHONE
NUMBER

These are the phone numbers to which the control panel will send the vocal messages by phone line. Each phone number will be entered like a number dialed on a key phone. The maximum number of digits is 15. After entering the last digit of the phone number, press [#] key. A 2 second pause for number dialing can be added by entering [*][3]. To clear the phone number enter [*][5][#]. Note: In order to enter 01-07 sections, [*] [8] [Master code] command may be used. SECTION [08] - MESSAGE DURATION/DIALING ATTEMPT NUMBER Enter 2 groups of 3 digits each (001..255). The first group of 3 digits represents message duration in seconds. The default duration is [030] seconds. The second group of 3 digits represents the dialing attempt number (for each programmed phone number). The default dialing attempt number is [002]. SECTION [09] - ZONE DEFINITIONS To programm the characteristics of zones 1-4 enter 4 groups of 2 digits. The first digit of each group represents the zone type and can have the value of: 0, 1, 2 or 3.

17

Cerber C41V1/Cerber C41V4


HOOKUP INSTALLATION & PROGRAMMING BOOK

[ 0 ] ENTRY/EXIT ZONE (DELAYED ZONE) An Entry/Exit zone is usually used for Entry/Exit doors. The Exit Delay starts when the system is armed. The zone may be opened and closed during the delay without causing an alarm. When the Exit Delay expires, zone opening will start the Entry Delay. During the Entry Delay, the keypad buzzer will sound continuously to indicate that the system should be disarmed. If the system is disarmed before the Entry Delay expired, no alarm will be generated. Entry and Exit Delay times may be independently programmed for 1 to 255 seconds in section 11. The default settings are 120 seconds for the Exit Delay and 30 seconds for the Entry Delay. This zone type can be programmed for Forced arming. [ 1 ] INSTANT ZONE Instant zones are normally used for door and window contacts. Instant zones are disabled during Exit Delay, but will generate an instant alarm if opened after Exit Delay expired. The Exit Delay is the same as for Delayed zones and is 120 seconds by default. [ 2 ] FOLLOWER ZONE The Follower zones are used with interior motion detectors and follow the standard Exit Delay. If entering the system is done through a Delayed zone, then the Follower zone will have the standard Entry Delay. If entering the system is done through a Follower zone without coming through a Delayed zone, an alarm will be generated. This zone type can be programmed for Forced arming. [ 4 ] 24-HOUR ZONE The 24-hour zones are permanently active. If such a zone is tripped, an alarm will be generated even if the system is disarmed. The second digit of each group represents the alarm type. There are six alarm types: [ 0 ] STEADY Send an alarm message and the siren will be enabled. [ 1 ] PULSE Send an alarm message and the siren will be enabled in pulse. After an pulsing alarm occurring all the other audible alarms will be pulsing alarms, until the siren will be stopped.
18

Cerber C41V1/Cerber C41V4


HOOKUP INSTALLATION & PROGRAMMING BOOK

[ 2 ] SILENT Sends an alarm message and the siren will be not enabled. [ 4 ] STEADY ALARM AND FORCED ARMING An alarm message will be send by phone line and the siren will be enabled. The system can be armed even if this zone is not secured. [ 5 ] PULSED ALARM AND FORCED ARMING An alarm message will be send by phone line and the siren will be enabled in pulse. The system can be armed even if this zone is not secured. [ 6 ] SILENT ALARM AND FORCED ARMING An alarm message will be send by phone line and the siren will be not enabled. The system can be armed even if this zone is not secured. NOTE: The forced arming alarm type is only available for Entry/Exit and Follower zones. Example: Zones are to be programmed this way: Zone 1 - Entry/Exit zone with steady alarm Zone 2 - Follower zone with steady alarm Zone 3 - Instant zone with steady alarm Zone 4 - 24 Hour zone with pulse alarm After entering the section by pressing [0] [9], enter the sequence: [0][0] [2][0] [1][0] [3][1] After each of the 2 digits, the keypad buzzer will sound 3 beeps. After entering the last 2 digits, the keypad buzzer will sound 6 beeps and exit the section 09 waiting for a new command. SECTION [10] - KEY ZONE DEFINITIONS Enter 2 digits in order to determine "KEY" zone features. The first digit represents the "KEY" zone type and can be: [ 3 ] PANIC OR TAMPER ZONE The Panic zone is permanently active. If such a zone is tripped, an alarm will be generated even if the system is disarmed. [ 4 ] ARMING/DISARMING BY KEY The system can be armed/disarmed by areturn key with NC contact. If the system is armed then, when zone is opened, the system will be disarmed. If the siren is enabled, then when zone is opened, the siren will be stopped.
19

The second digit represents the alarm type for panic or tamper zone and the alarm type as well when [*] and [#] keys are pressed simultaneously (see section 09). SECTION [11] - SYSTEM TIMES Enter 3 groups of 3 digits each (001 to 255 seconds), to establish the three system delays: Entry Delay The Entry Delay determines the lapse of time allowed between the activation of an Entry/Exit zone and system disarming. If the system is not disarmed during this delay, an alarm will be generated. The default Entry Delay is 30 seconds. Exit Delay The Exit Delay determines the lapse of time allowed between entering an access code to arm the system, and the activation of an Entry/Exit zone to exit the protected area. The default Exit Delay is 120 seconds. Bell cut-off time The bell cut-off time represents how long the siren will be enabled when an alarm occurs. When an alarm occurs, the siren will sound until this period of time is exceeded or an access code is entered. Example: These times are to be programed this way: Entry time - 10 seconds Exit time - 60 seconds Bell cut-off time - 3 minutes After entering the section by pressing [1][1], enter the sequence: [0][1][0] [0][6][0] [0][0][3] After each of the 3 digits, the keypad buzzer will sound 3 beeps. After entering the last 3 digits, the keypad buzzer will sound 6 beeps and exit the section 11 waiting for a new command. SECTION [12] INSTALLER'S CODE CHANGING The default value for the Installer's Code is [0269]. It is strongly recommended to change this code after completing the installation of the alarm system. Keep the new code in a safe place. Enter 4 digits [X] [X] [X] [X]. Next, the keypad buzzer will sound 6 beeps and will exit section 12 waiting for a new command.

Cerber C41V1/Cerber C41V4


HOOKUP INSTALLATION & PROGRAMMING BOOK

SECTION [13] PROGRAMMABLE OUTPUT OPTIONS FOR PGM1, PGM2 Enter 2 digits. The first digit refers to PGM1 and the second one refers to PGM2, and they stand for: [0] LATCH ON ALARM The output goes to ground in alarm circumstances, and is shut OFF when disarming. [1] SYSTEM STATE FOLLOW The output goes to ground when arming, and is shut OFF when disarming. [2] ENTRY DELAY The output goes to ground during the Entry Delay. [3] EXIT DELAY The output goes to ground during the Exit Delay. [4] TROUBLE The output goes to ground while there is a trouble in the system (AC power loss, low battery, unsuccessful communication attempt). [5] CONTINUOUS SIREN The output goes to ground while the siren is sounding continuously. [6] PULSING SIREN The output goes to ground while the siren is sounding in pulses. [7] SILENT SIREN The output goes to ground while any silent alarm is enabled. [8] PANIC The output goes to ground when panic feature is activated (panic zone or by simultaneously pressing [*]+[#] keys). SECTION [14] DIALING MODE/MESSAGE SELECTION Enter 2 digits. The first digit represents: 0 = Pulse dialing 1 = DTMF dialing

21

Cerber C41V1/Cerber C41V4


HOOKUP INSTALLATION & PROGRAMMING BOOK

When a phone line transmission is initiated within the first 5 seconds, the control panel checks up the presence of the free line tone. If the line tone is detected, then the control panel dials immediately the programmed phone number. If after 5 seconds the line tone is not detected, the control panel will still dial the programmed phone number. The second hex digit represents: 0 = the vocal message is not sent Cerber C41V1 control panel 1 = sends the alarm message when one of zones 1-4 is tripped 2 = sends the alarm message when Panic is activated from the keypad 4 = sends the alarm message when AC Loss 8 = sends the alarm message when Ambush If the message is sent when several of the four events occur simultaneously then, in this location the hexadecimal digit which represents the sum of digits corresponding to the selected messages will be programmed, according to following table:

22

Cerber C41V1/Cerber C41V4


HOOKUP INSTALLATION & PROGRAMMING BOOK

The alarm message is sent to: The second programmed One of zones 1-4 Panic from AC Loss Ambush digit Activating the keypad 0 1 2 3 4 5 6 7 8 9 A B C D E F

CERBER C41V4 CONTROL PANEL 1 = sends Message 1 2 = sends Message 2 4 = sends Message 3 8 = sends Message 4 If messages are successively sent to each programmed phone number when several of the four events occur simultaneously then, in this locationt the hexadecimal digit which represents the sum of digits corresponding to selected messages will be programmed, according to the following table:

23

Cerber C41V1/Cerber C41V4


HOOKUP INSTALLATION & PROGRAMMING BOOK

The second programmed digit 0 1 2 3 4 5 6 7 8 9 A B C D E F

It is sent a succession consists of: Message 1


Message 2

Message 3

Message 4

PROGRAMMING FORM
[01] FIRST PHONE NUMBER PROGRAMMING
Default: not programmed [ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ]

[02] SECOND PHONE NUMBER PROGRAMMING


Default: not programmed [ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ]

[03] THIRD PHONE NUMBER PROGRAMMING


Default: not programmed 24 [ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ]

Cerber C41V1/Cerber C41V4


HOOKUP INSTALLATION & PROGRAMMING BOOK

[04] FOURTH PHONE NUMBER PROGRAMMING


Default: not programmed [ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ]

[05] FIFTH PHONE NUMBER PROGRAMMING


Default: not programmed [ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ]

[06] SIXTH PHONE NUMBER PROGRAMMING


Default: not programmed [ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ]

[07] SEVENTH PHONE NUMBER PROGRAMMING


Default: not programmed [ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ][ ]

[08] MESSAGE DURATION/DIALING ATTEMPT NUMBER PROGRAMMING


Default: [ ][ ][ ] [ ][ ][ ]

[09] ZONE DEFINITIONS


Default [0] [0] [1] [0] [2] [0] [2] [0] [ ][ ] [ ][ ] [ ][ ] [ ][ ] Zone 1 Zone 2 Zone 3 Zone 4 Digit 1 [0] Entry/Exit [1] Instant [2] Follower [3] 24-Hour Digit 2 [0] Continuous [1] Pulsing [2] Silent [4] Continuous with Forced arming [5] Pulsing with Forced arming [6] Silent with Forced arming

[10] KEY ZONE DEFINITION


Default [4] [0] [ ][ ] KEY Zone Digit 1 [3] Panic or tamper [4] Arming/disarming by key [2] Silent Digit 2 [0] Continuous [1] Pulsing

[11] SYSTEM TIMES


Default [0] [3] [0] [ ] [ ] [ ] Entry delay (seconds) [1] [2] [0] [ ] [ ] [ ] Exit delay (seconds) [0] [0] [4] [ ] [ ] [ ] Bell cut-off time (minutes)

25

Cerber C41V1/Cerber C41V4


HOOKUP INSTALLATION & PROGRAMMING BOOK The available values are from 001 to 255. Do not enter 000.

[12] INSTALLER'S CODE


Default

[0] [2] [6] [9]

[ ][ ][ ][ ]

[13] PROGRAMMABLE OUTPUT OPTIONS FOR PGM1, PGM2


Default [0] [0] [ ] [ ] PGM1 Output PGM2 Output Options [0] Latch on alarm [1] Follow system state [2] Entry delay [3] Exit delay [4] Trouble [5] Continuous siren [6] Pulsing siren [7] Silent siren [8] Panic

[14] DIALING MODE/MESSAGE SELECTION Default Digit 1 Digit 2 [0] [0] [0] Pulse dialing [0] The messages are not sent
[1] DTMF dialing [1] Alarm messages for zones 1-4 [2] Panic from the keypad [4] AC LOSS [8] Ambush Any sum between previous digits for

26

Cerber C41V1/Cerber C41V4


HOOKUP INSTALLATION & PROGRAMMING BOOK sending several messages [F] Sends all messages

WARNING LIMITATIONS OF THIS ALARM SYSTEM


While this system is an advanced design security system, it does not offer guaranteed protection against burglary, fire or other emergency. Any alarm system, wether commercial or residential, is subject to compromise or failure to warn for a variety of reasons. For example: Intruders may gain access through unprotected openings or have the technical sophistication to bypass an alarm sensor or disconnect an alarm warning device. Intrusion detectors (e.g. passive infrared detectors), smoke detectors, any many other sensing devices will not work without power. Battery operated devices will not work without batteries, with dead batteries or if the batteries are not put in properly. Devices powered solely by AC will not work if their AC power supply is cut off for any reason, however briefly. A user may not be able to reach a panic or emergency button quickly enough. Smoke detectors may not activate or provide early warning for a variety of reasons. Some of the reasons smoke detectors used in conjunction with this system may not work are as follows> Smoke detectors may have been improperly installed and positioned. Smoke detectors may not sense fires that start where smoke cannot reach the detectors, such as chimneys, in walls, or roofs, or on the other side of closed doors. Smoke detectors may not sense a fire on another level of a residence or building. A second floor detector, for example, may not sense a first floor or basement fire. Moreover, smoke detectors have sensing limitations. No smoke detector can sense every kind of fire every time. In general, detectors may not always warn about fires caused by carelessness and safety hazards like smoking in bed, violent explosions, escaping gas, improper storage or flammable materials, overloaded electrical circuits, children playing with matches, or arson. Depending on the nature of the fire and/or the location of the smoke detectors, the detector, even if it operates as anticipated, may not provide sufficient warning to allow all occupants to escape in time to prevent injury or death. Passive Infrared Motion Detectors can only detect intrusion within the designed ranges as diagrammed in their installation manual. Passive Infrared Detectors do not provide volumetric area protection. They do not create multiple beams of protection, and intrusion can only be detected in unobstructed areas covered by the beams. They cannot detect motion or intrusion that take place behind walls, ceiling, floors, closed doors, glass partitions, glass doors or window. Mechanical tampering, masking, painting, or spraying of any material on the mirrors, windows or any part of the optical system can reduce their detection ability. Alarm warning devices such as sirens, bells or horns may not alert people or wake up sleepers who are located on the other side of closed doors. If warning devices sound on a different level of the residence from the bedrooms, then they are less likely to waken or alert people inside the bedrooms. Even persons who are awake may not hear the warning if the alarm is muffled by noise from a stereo, radio, air conditioner or other appliances, or by passing traffic, Finally, alarm warning devices, however loud, may not warn hearing-impaired people or waken deep sleepers. Telephone lines needed to transmit alarm signals from a premises to a central monitoring station may be out of service or temporarily out of service. Telephone lines are also subject to compromise by sophisticated intruders. Even the system responds to the emergency as intended, however, occupants may have

27

insufficient time to protect themselves from the emergency situation. In the case of a monitored alarm system, authorities may not respond appropriately. The most frequent cause of an alarm system not functioning when an intrusion or fire occurs is inadequate maintenance. This alarm system should be tested weekly to make sure all sensors are working properly.

TECHNICAL SPECIFICATIONS Number of zones Zone type EOL resistor Programmable outputs PGM1, PGM2 Max. current load of PGM1, PGM2 outputs Main board tipical current consumption Keypad tipical current consumption Rated power for main board operation

4+1 Tamper zone programmable 2,2kOhm 2 100mA 50mA 12mA 13,8 - 14Vcc