0 valutazioniIl 0% ha trovato utile questo documento (0 voti)
46 visualizzazioni5 pagine
This document provides instructions for installing and setting up telecommunications equipment at a site. It includes identifying the indoor and outdoor areas of the site, the equipment and tools needed. It describes receiving materials and ensuring health and safety precautions. The main sections cover installing BTS equipment and parts, GSM antennas and feeder cables, transmission equipment, and connecting various types of cables. It emphasizes proper routing of cables, grounding, and weatherproofing installations. Precautions are outlined such as not switching power without tracing circuits and not working on towers without safety equipment.
This document provides instructions for installing and setting up telecommunications equipment at a site. It includes identifying the indoor and outdoor areas of the site, the equipment and tools needed. It describes receiving materials and ensuring health and safety precautions. The main sections cover installing BTS equipment and parts, GSM antennas and feeder cables, transmission equipment, and connecting various types of cables. It emphasizes proper routing of cables, grounding, and weatherproofing installations. Precautions are outlined such as not switching power without tracing circuits and not working on towers without safety equipment.
Copyright:
Attribution Non-Commercial (BY-NC)
Formati disponibili
Scarica in formato PDF, TXT o leggi online su Scribd
This document provides instructions for installing and setting up telecommunications equipment at a site. It includes identifying the indoor and outdoor areas of the site, the equipment and tools needed. It describes receiving materials and ensuring health and safety precautions. The main sections cover installing BTS equipment and parts, GSM antennas and feeder cables, transmission equipment, and connecting various types of cables. It emphasizes proper routing of cables, grounding, and weatherproofing installations. Precautions are outlined such as not switching power without tracing circuits and not working on towers without safety equipment.
Copyright:
Attribution Non-Commercial (BY-NC)
Formati disponibili
Scarica in formato PDF, TXT o leggi online su Scribd
r| Remarks/ l-i| Description/ (ii General/ i- a) Identification of site with indoor and outdoor snaps./ i:- dh igpku (ir ( ( li lrn
b) Identification of equipments./ ii | ri c) Identification of Tools for installation./ -iiln l iii | ri
d) Material receiving at site/ i:- i-i in| Operational Health & Safety/ i -(i- i ii
a) Use of Safety belt and Helmet at sites./ i:- ii (~- i r- - i :-n-i
b) Other safety precautions (Nokia and Ericsson)./ ii i(ili (ili i li)
Installation/ -iiln i l- a) BTS and BTS parts/ (|.-|. i (|.-|. 1- Opening of cabinet from box./ l(- i (i iii
2- Installation of cabinet/ l( - | -iii 3- Grounding of cabinet/ l( - | n iln 4- Installation of cards and distribution of power/ i | -iii nii l(| ( | li
5- Power to BTS from SMPS/ ,.- |.. (|.-|. i i( ( | li
6- Internal caballing between Duplexer and TRX cards of BTS./ i (|.-|.. -|. i. i (| inl (ln
7- Installation and routing of feeder jumpers from BTS to feeder cable./ - | -iii i (|.-|.. | ( nii
8- Installation of signal cables/ n ( | -iii
b) GSM Antenna and Feeder Cable/ |..- -|i i | (
1- Opening of GSM antenna box./ |..- -|i (i i iii
2- Assembling of GSM antenna mounting kit./ |..- -|i iini l- i i | li
3- Pulling of GSM antenna up the tower and hang on tower./ |..- -|i i -i( n i|i i -i( -ii
4- Set the orientation tilt and mechanical tilt./ - lil(i l(n n ni( i ili ni(
5- Routing and connecting of feeder jumper at antenna port on tower./ ,-|i i- | i ii i i r| -in ii
6- Weather proofing of joint between antenna port and jumper./ , -|i i- i (| -i - ii i
7- Assembling and installation of feeder clamps/ | i -iiln i i | l(li
8- Unwind the feeder role, cut the length as per requirement and make the feeder connector./ | i i iii i(nii (i: i-i i | - (ii+
9- Pulling of feeder cable up the tower and connect with jumper./ | ( i -i( i|i i ii
10- Routing, bending, and pulling inside the shelter and feeder earthing of feeder cable./ | ( i r| -in i|i li n i | i -ii+
11- Weather proofing and labeling of GSM antenna./ -i - ii i |..-. i ln i
c) Transmission/ Vkalfeku 1- Opening of MW antenna box. -|i (i i iii
2- Assembling of MW antenna, As per specification with the help of instruction paper which is already attached in m/w antenna box, ODU, alignment unit and polarization/ -i:i(( -|i i l(ii ii li | -iii i i(|i
3- Pulling of MW antenna up the tower, hang on tower and set the orientation./ -i:i (( -|i i -i( i|i -ini i (|i i
4- Assembling and installation of IF Clamps./ i: . - | i i i -iii
5- Unwind the IF cable, cut the IF cable as per requirement and make the IF connector./ | i i iii i(nii (i: i-i i | - (ii+
6- Pulling of IF cable and connect with ODU./ i: . ( -i( i|i i li ii
7- Routing, bending, pulling inside the shelter and IF earthing of IF cable./ i: .. ( i r| -in i|i -ii i i: . ( | li n i
8- Assembling, installation and power to IDU from SMPS./ i:.|.. i i i -iii i .-. |. l(| ( i
9- Alignment of MW antenna./ -i:i(( -|i | l-iln
10- Weather proofing and labeling of MW antenna./ -i:i(( -|i | -i - ii i nii
d) Connectorization of,/ - (ii 1- Feeder connector (Nokia and Ericsson)/ | - (ili i l) 2- IF connector (PDH and SDH)/ i: .. - .|.|. i .|.
3- R J 45 connector as configuration./ i. r - ( n i
e) Earthing/ niln 1- Feeder earthing./ | n iln 2- IF earthing./ i:. niln 3- Equipments earthing./ ii | n iln
Precautions / i(iili 1. Do not Switch Off any MCB without tracing while removing any equipment. i: i| i li l -(ln -.|.(|. i l(i (( i + 2. Do not remove M/W without tracing and without informing OMC Engineer. -i:i (( l(i i ( l(i i .-.|. :|l i (ni li + 3. Do not Stand on feeder or IF cable while working i- n - ( + 4. Do not approach site without permission from technician /Supervisor. i: - -|li (i: | -n| l(i i: - i 5. Do not work without safety Eqpt. on tower more then 3 mtr High. s -|. i(i i: (i -i( l(i ii i- + 6. Do not connect Jumper connection. - i + 7. Do not fix moduler. -i i + 8. Do not leave any tool at site. i: - i: i i si + 9. Do not make site dirty. i: - i n(i + 10. Do not connect Power connections. i: i( i + 11. Do not step on any eqpt. l| | i + 12. Cable crossing ( iln! 13. Poor IF cable routing of Nokia MW Hope i:. ( nn nit nt! 14. DDF cable not Routed Property || ( nn nit nt! 15. Earth cable not routed properly n iln ( nn nit nt! 16. Rear view of Nokia MW Hop ili MW Hop i | ( ! 17. RF Jumper labeling RF ln i! 18. Feeder earth cable routing wrong | n iln nn! 19. Earth cable not routed properly n iln n r| l(si: n:! 20. Not Routed Properly n r| l(si: n: ! 21. Shelter Clean - | i: ! 22. Tape Putty done wrong - ~| n r| nit nt! 23. Lugs not inserted properly n n r| nit nt! 24. TIE not cut -i: r| i-| nt! 25. Surge Arresters & Marking -- i !