Sei sulla pagina 1di 74

ENDOCRINE MANUAL FOR THE REPRODUCTIVE ASSESSMENT OF DOMESTIC AND NON-DOMESTIC SPECIES

Janine Brown, Ph.D. Susan Walker, M.S. Karen Steinman, B.S.

Conservation & Research Center National Zoological Park Front Royal, VA

2005 CRC Endocrine Laboratory. All rights reserved.

TABLE OF CONTENTS Page I. II. III. Introduction Principles of Immunoassays Principals of Enzymeimmunoassays Essential components of an EIA Steps to development of an EIA Types of Enzymeimmunoassays Single antibody EIA Double antibody EIA Determining appropriate antibody dilution Effect of antibody dilution on standard curve General Assay Terminology Antibody characteristics Assay characteristics Types of assay variation Monitoring Quality Control Why is quality control necessary? Proper use of the standard curve Monitoring standard curve parameters Monitoring assay quality Example Cortisol EIA control monitor Laboratory Immunoassay Validation Parallelism Recovery/Accuracy check Extraction efficiency Biological Validation of Methods HPLC for Analysis of Metabolites Immunoassay Troubleshooting Color and curve problems Loss of binding Shifted standard curve High non-specific binding Poor precision and high CVs Sample Collection/Storage Methods Blood Urine Feces Fecal dilutions Hormone Extraction Methods Blood Urine Conjugated steroid analysis Fecal extraction methods 1 1 2 2 3 4 4 5 7 7 8 8 9 9 10 10 10 10 10 13 14 14 15 17 18 19 20 20 20 21 21 21 23 23 24 24 24 25 25 25 25 26

IV.

V.

VI.

VII.

VIII. IX. X.

XI.

XII.

Endocrine Manual Brown et al. 2005

ii

Extraction efficiency protocol Fecal extraction sheet XIII. Calculating EIA Results Reading the plate Calculating results from OD Average blank value Data matrix/table OD Converting data from feces Converting data from urine Tips for reading EIA plates Assay Protocols Creatinine assay Checkerboard titration for EIA Cortisol EIA Pregnane EIA Testosterone EIA Estrone conjugates EIA Assay Reagents and Supplies Steroid EIA recipes Creatinine assay recipes Assay reagents for steroid and LH EIA General supplies General equipment Other Review of Steroid Metabolism Review of Reproductive Physiology Review of Adrenal Metabolism

28 30 31 31 31 31 32 35 36 36 37 37 39 42 45 48 51 54 54 55 56 57 58 59 60 69 71

XIV.

XV.

XVI. XVII. XVIII.

Endocrine Manual Brown et al. 2005

iii

I. INTRODUCTION Immunological techniques, like radioimmunoassays (RIA) and enzyme immunoassays (EIA), are used because they are capable of measuring small quantities of hormones. RIAs are highly sensitive and have been the most common immunological methods for hormone analysis used to date. However, an RIA laboratory needs to be licensed for the use of radioisotopic tracers, and gamma and beta scintillation detection equipment are comparatively expensive. By contrast, EIAs do not utilize radioactivity, equipment is less expensive and reagents are easy to prepare, are highly stable and have a long shelf-life. Many EIAs are now as sensitive as RIAs and so are gaining in popularity. The purpose of this manual is to acquaint the reader with both RIA and EIA techniques; however, the emphasis will be on EIA because of its universal adaptability and potential for development as field tests. II. PRINCIPLES OF IMMUNOASSAYS The essence of an immunoassay is the competition between added labeled antigen (tracer) and unlabeled antigen (i.e., hormone in the sample) binding to an antibody. Highly sensitive immunoassays rely on the use of a limited amount of antibody. If the primary antibody is in excess, there is little or no competition in binding between labeled and unlabeled antigen, thus no discrimination in measuring concentration of the unknown. With a limited amount of antibody, samples with higher concentrations of hormone have a greater chance of competing against labeled antigen for antibody binding than low concentration samples, and this relationship is proportional to the amount of unlabeled hormone added. Antigen-antibody binding in RIA and EIA follows the Law of Mass Action. The distribution between the bound and unbound phases is directly related to the total amount of antigen (Ag) in the presence of a fixed amount of antibody (Ab), where k1 and k2 denote the association (forwards reaction) and dissociation (reverse reaction) constants, respectively. k2 Ag + Ab AgAb k1 In the beginning, the rate of the reaction is greater in the forward direction (k1) until equilibrium is achieved; at equilibrium there will be no further net change in the concentrations on either side of the equation. The affinity constant: K = k1/k2

High K implies that the reaction is favored in the forward direction; low K implies the reaction is favored in the opposite direction. Given a constant amount of antibody of fixed K, the ratio of bound to free antigen will be related to the total amount of antigen present. Antibodies are produced against a specific antigen by immunizing an animal and collecting immune serum. Primary antibody (or antisera), also called the first antibody, refers to the hormone-specific antibody; the one that was produced from immunizing an animal against the hormone to be measured. Primary antisera can be produced against large proteins by direct injection of antigen solubilized in a carrier that stimulates the immune response (i.e., Freunds adjuvant). Immunization against small proteins or steroids (i.e., haptens) requires conjugation to immune stimulating molecules (i.e., albumins, keyhole limpet antigen, etc.). Primary antibodies are often produced in rabbits, guinea pigs and monkeys. Second antibodies are those produced by immunizing a different species like a goat or sheep against IgGs of the species that produced the primary antisera (e.g., goat anti-rabbit antisera). The second antibody is not specific for the primary antigen, but is used in sandwich assays. Polyclonal antibodies are produced by injecting an animal with a purified or partially purified antigen and collecting the immune serum. The antisera produced contains a variety of immunoglobulins against the antigen (or antigens for partially purified immunogen) or conjugate molecule (in the case of conjugated haptens). Antibody production is limited to the life span of the immunized animal and success of reimmunizations. Monoclonal antibodies are produced by immunizing an animal (e.g., mouse) and cloning individual antibody cells to produce a single variant antibody against an antigenic determinant on the hormone. Antibody production is indefinite as long as the cloned cells are maintained (frozen in liquid nitrogen).

Endocrine Manual Brown et al. 2005

III. PRINCIPLES OF ENZYMEIMMUNOASSAY EIA is also known as ELISA (Enzyme Linked ImmunoSorbent Assay). EIAs depend on the assumption that an antigen can be linked to an enzyme and retain both immunological and enzymatic activity in the resultant conjugate. The soluble antigen or antibody must also be linked to an insoluble phase in a way in which the reactivity of the immunological component is retained. ESSENTIAL COMPONENTS OF THE EIA: Solid Phase: The solid phase is the polystyrene microtiter plate. Antibody: An immunoglobulin produced against a specific antigen. Polyclonal antibodies must be affinity purified for EIA. Coating buffer: The antibody is diluted with an alkaline buffer, usually a carbonate/bicarbonate buffer of pH 9.6, which causes it to passively adsorb to the well of the microtiter plate. Wash solution: Each incubation is terminated by a washing step. The wash removes all unbound components from the plate. Enzyme conjugate (tracer): The enzyme conjugate is the component of the assay that permits detection of antigen concentration. For direct, single antibody EIAs, a common enzyme conjugate is hormone conjugated to horseradish peroxidase (HRP). For double antibody sandwich EIAs, the enzyme conjugate complex is a biotin labeled hormone that binds to peroxidase-labeled streptavidin. Assay buffer: Phosphate or Tris buffers of pH 7.0 are commonly used. Sodium azide cannot be used in buffers for single antibody EIAs because the HRP is inhibited by azide. Sample dilutions, standards and enzyme conjugate are made up in assay buffer. Standards or unlabeled antigen: The standard is usually the same antigen that was used to make the antibody and the same as the enzyme conjugate, or is structurally similar so that it crossreacts with the first antibody. Standards are used in a series of known concentrations against which unknown concentrations of antigen in the sample can be measured and calculated. Substrate: The substrate reacts with the bound enzyme conjugate and changes color. It consists of three components: buffer, chromagen, and catalyst. The buffer has an acidic pH and is either citric acid or phosphate citrate buffer. The chromagen is the color changer and is usually azino-bis-3-ethyl benzthiazoline-6-sulfonic acid (ABTS) or tetramethylbenzadine (TMB). ABTS turns a green color and TMB turns blue. The catalyst is what causes the reaction, via oxidation-reduction, and is hydrogen peroxide or sodium perborate. Stop solution: Sulfuric acid solution that stops the substrate reaction and allows the plate to be read at any time. It is used primarily in the double antibody EIA. It causes the blue substrate to turn yellow.

STEPS TO DEVELOPMENT OF AN EIA 1. Determination of antibody titer. An appropriate antibody titer is one that results in adequate color change while retaining good sensitivity. In general, increasing the antibody concentration increases the enzymatic color change, but decreases assay sensitivity. Decreasing antibody concentration (more dilute) increases sensitivity, but the color change is less. 2. Determination of enzyme conjugate dilution. Increased enzyme conjugate concentration results in a stronger color change but decreased assay sensitivity, whereas decreased conjugate concentration increases assay sensitivity but reduces color intensity. An appropriate combination of antibody and enzyme conjugate results in adequate color intensity with high assay sensitivity. 3. Development of standard curve. Incubation of a fixed amount of enzyme conjugate and antibody in the presence of different concentrations of standard (unlabeled antigen). A graph is generated that depicts the relationship between the percentage of bound enzyme conjugate (relative to the maximum binding of the enzyme conjugate, zero well) to the concentration/mass of the standard added. The relationship of the percent binding and the standard mass is inversely proportional. 4. Time and temperature of incubation. Incubation time can be decreased with increased temperature but antibody-antigen binding and substrate-enzyme conjugate binding can decrease if the temperature is too high. 5. Definitions:

Endocrine Manual Brown et al. 2005

Total Binding (TB): Maximum binding of enzyme conjugate (labeled antigen) to the antibody in the absence of competition from unlabeled antigen (standard or unknown sample). Also called zeroes and should have the highest optical densities. It is assumed to be 100% binding of the enzyme conjugate. Most assay systems attempt to reach optical densities of 0.8-1.0 in the zero wells. Unknowns: Unknown hormone concentrations in samples are determined by comparing the specific binding of the samples to the binding obtained from standard hormone concentrations of known mass. Non-specific binding (NSB): Amount of binding that occurs in the plate that is NOT due to the antibody, but to other components of the assay. It also accounts for the amount of interference the plastic bottom of the plate produces when the light from the plate reader is refracted. The NSB wells should be less than 10% of the maximum binding wells (zeroes). The NSB results are subtracted from the sample/standard results (this is done by the microplate reader). NSB can be reduced by adding a protein blocking buffer after antibody coating, adding detergent to the assay buffer or increasing the number of washes.

Endocrine Manual Brown et al. 2005

IV. TYPES OF ENZYMEIMMUNOASSAYS SINGLE ANTIBODY EIA (e.g., cortisol) A hormone-specific antibody (or first antibody) is passively adsorbed (i.e., coated) to a polystyrene microtiter plate. Unabsorbed antibody is washed away. Known (standards) and unknown (samples) concentrations of hormone (unlabeled antigen) and the hormone-specific enzyme conjugate (HRP) (the labeled antigen) are added to the well. The labeled and unlabeled antigens compete for binding sites on the antibody during the incubation phase. The unbound components are washed away. The substrate is added and reacts with the bound enzyme conjugate and changes color. The more color change in the well, the more enzyme conjugate is bound, meaning less hormone. The relationship of color to hormone concentration is inversely proportional. The zero wells contain only enzyme conjugate so there is no competition for antibody binding. The zero wells represent the maximum binding of the labeled antigen and, hence, have the most color change. Example: Y First antibody Free hormone HRP-labeled hormone Substrate

1) Antibody binding to solid phase (known as coating) YYYYYYYY 2) Competition for antibody binding sites by labeled and sample hormone

YY Y Y YY YY 3) Wash away excess unbound hormone YYYYY YYY 4) Substrate binding to HRP-labeled hormone YYYYY YYY YYYYYY YY Zero standard Maximum color YYY YYYYY High standard Minimum color

Endocrine Manual Brown et al. 2005

DOUBLE ANTIBODY EIA (e.g., luteinizing hormone) In this antibody system a second antibody (i.e., anti-first antibody) that recognizes the first antibody and other IgGs is used to coat the microtiter plate. Following incubation, unbound second antibody is decanted and a blocking buffer, usually containing a protein such as BSA is added to reduce non-specific binding. After incubation, plates are washed and any unbound components removed. The first antibody and unlabeled antigens (sample or standards) are added to the wells. The first antibody binds to the second antibody and the free hormone then binds to the first antibody. Reagents are allowed to incubate followed by incubation with the biotin-labeled antigen. Plates are washed, removing any unbound biotin-labeled antigen, and streptavidin-peroxidase is added. The distinguishing feature of the avidin-biotin system is the extremely high affinity of the avidin (from egg white or a bacteria -Streptomyces avidinii) for biotin (a water-soluble B vitamin). The speed and the strength of binding between these two molecules is used to provide an amplification of the enzyme signal. This binding also is not influenced as much by extreme temperatures or pH levels. The peroxidase enzyme is incorporated into the streptavidin and after binding to the biotin, forms the enzyme conjugate complex. Following plate washing substrate (TMB) is added. The chromagen within the substrate reacts with the bound enzyme conjugate and changes color. Similar to the direct single antibody competitive EIA, the more color change in the well the more enzyme conjugate bound, meaning less hormone. The relationship of color to hormone concentration is inversely proportional. Example: Second antibody (recognizes IgGs) Y First antibody (recognizes hormone antigen) Substrate Free hormone BSA Biotin-labeled hormone Streptavidin-peroxidase (enzyme)

1) Second antibody (anti-first antibody) binding to solid phase (coating)

2) BSA is added to block non-specific binding sites

Endocrine Manual Brown et al. 2005

3) Addition of hormone-specific, first antibody, biotin-labeled hormone, and free hormone Y Y Y Y

4)Wash away unbound components Y Y Y Y 5)Addition of streptavidin-peroxidase (enzyme)

Y Y 6)Addition of substrate

Y Y

Y Y Y Y

7) Results Y Y Y Y Zero Maximum color Y Y Y Y High standard Minimum color

Endocrine Manual Brown et al. 2005

HOW TO DETERMINE APPROPRIATE ANTIBODY DILUTION FOR EIA

100

80

60

% Binding (TB/TC)
40

Want Ab to bind ~30% of labeled hormone

20

Use Ab at 1:120,000 dilution


0 1 10 100 1000

Ab Dilution (x 1000)
Appropriate first antibody concentration is determined by running a titration curve, which involves incubating serial dilutions of first antibody with a constant amount of HRP. Calculate the % binding of the antibody to tracer and plot as a linear-log curve. The best antibody dilution (one that provides good sensitivity with adequate detectibility) is ~30% (range 20-50%).

EFFECT OF ANTIBODY DILUTION ON STANDARD CURVE CHARACTERISTICS


120 100 80

Correct too much not enough

% B/TB 60
40 20 0 1 10 100 1000

Standard Concentration
Inappropriate first antibody concentration will result in a poor standard curve that is too flat on the top or bottom portion. Too much antibody also will reduce assay sensitivity.

Endocrine Manual Brown et al. 2005

VII. GENERAL ASSAY TERMINOLOGY ANTIBODY CHARACTERISTICS Sensitivity: The ability to detect small quantities of antigen. It is the lowest concentration of antigen that can be statistically distinguished from a sample with no antigen. - objective determination - calculated as the value 2 SD from the mean response of the blank or zero (Bo) tube. - subjective determination - the value at 90% or 95% of maximum binding. The ability of the antibody to discriminate between antigens. The ability of an antibody to have immunoreactivity with a more than one antigen. Crossreactivity of an antibody with other hormones is determined using binding inhibition curves. It is expressed as the standard concentration at 50% binding divided by the concentration of the competitive antigen at 50% binding, expressed as a percentage.

Specificity: Crossreactivity:

Examples: Hormone C is detected but the antibody is not as specific for it. The crossreactivity is less than 100%. The antibody for progesterone crossreacts better with hormone D than the standard. The crossreactivity is over 100%. Hormones A and B only bind the antibody at high concentrations and crossreactivity cannot be calculated.

Crossreactivity of Different Antigens on a Progesterone EIA


Progesterone Standard Hormone A Hormone B Hormone C Hormone D

100 80 60 % B/TB 40 20 0
0.1 1 10 100

1000

Standard Concentration (ng)

Endocrine Manual Brown et al. 2005

ASSAY CHARACTERISTICS Accuracy: The degree to which the measured concentration corresponds to the true concentration of a substance. This is related in part to the specificity of the assay. Precision: Refers to the repeatability of a measured value or the consistency of results. It is a measure of random error defined as the variation among replicate measurements of a defined sample. It is expressed as the Coefficient of Variation (%CV) which is the (Standard Deviation/Mean)*100. TYPES OF ASSAY VARIATION Intra-assay variation: The variation within assays determined by repeated analysis of samples, typically low, medium and high, within a single assay. Inter-assay variation: The variation between assays determined by repeated analysis of the same sample in several assays. These samples are called controls and should bind at 30% and 70%. Note: A sample can be precise, but not accurate. This occurs when the measured value deviates from the true value as a result of using a non-specific first antibody or to systematic error, like improperly calibrated weighing or measuring equipment, improper technique (pipetting) or sample problems.

Endocrine Manual Brown et al. 2005

VIII. MONITORING QUALITY CONTROL WHY IS QUALITY CONTROL NECESSARY? Proper validation and standardization of an assay is only the first step towards establishing a reliable endocrine monitoring program. Subsequent assessment of assay quality and consistency is absolutely necessary to assure the biological relevance of results. For every assay system there is an inherent level of error which must be accepted. A quality control program indicates when that level of error becomes unacceptable. Quality control samples only have value if their analysis provides a reasonable confidence in data for the whole assay, or reflects a true error in the method. It is an ongoing process; the value of quality control values increases with time.

PROPER USE OF THE STANDARD CURVE Assay range (the 20-80% rule): A subjective method of sample exclusion which eliminates the use of values in which the binding is less than 20% or greater than 80% of maximum binding. All outliers are re-analyzed after appropriate modification (i.e., taking more or less sample to the assay). This rule is based on the assumption that most standard curves are linear between 20 and 80% binding, and therefore the dose response is linear. The binding cut-off limits may vary, however, and should be appropriate for each assay.

MONITORING STANDARD CURVE PARAMETERS Total binding (%B/Bo): Indicates the maximum binding of label in the given assay system. Given that the assay parameters are unchanged, the maximum binding should remain relatively constant from assay to assay. A decrease in binding suggests one or more assay factors are not optimized (see Troubleshooting). Non-specific binding (%NB/Bo): The amount of binding due to factors other than specific antibody binding. It should remain constant from assay to assay. It also should be kept to a minimum, generally less than 5% of the total counts added. An increase in NSB again suggests one or more assay factors are not optimized (see Troubleshooting). Effective dose values (ED20, ED50, ED80): Gives a good estimate of the overall shape of the curve. The ED50 is especially useful for indicating changes in assay sensitivity. The ED20 and ED80 can also indicate changes in the slope of the curve.

MONITORING ASSAY QUALITY How is quality control monitored? Assay consistency is monitored by analyzing internal control samples, which are treated as unknowns, but are run in every assay. - how many to run? Usually 2 - 3 controls, assayed in duplicate or triplicate. Much of this depends upon the variability of the assay. - what concentrations to run? Controls should provide an estimate of variability over the working range of the standard curve. Recommend controls be run at ~30% (high concentration), 50% (medium) and 70% (low) of maximum binding.

Endocrine Manual Brown et al. 2005

10

- what samples can be used as controls? Almost any biological material containing the relevant antigen, including serum pools, fecal extracts, purified steroids diluted in buffer or other fluid (provided it does not interfere with the assay), pituitary extracts, urine pools, purchased standards, etc. 1. prepare a large pool projected to last for several years. 2. divide the material into small aliquots to avoid repeated freeze-thawing. 3. keep the aliquots in a safe freezer (preferably one with a temperature alarm). 4. store all materials, including samples, in a freezer that is NOT frost- free. 5. do not allow controls to run out before making up new controls. Assay coefficients of variation: (%CV = standard deviation/mean times 100) - intra-assay CV - determines the within assay error (the error associated with running the same sample in one assay). Most accurately determined by calculating the variation in assaying multiple replicates of one sample throughout the assay (e.g., n = 10 replicates). More typically, the average intra-assay CV is calculated from the internal controls assayed at the beginning of the assay. A third method is to calculate the average CV of all unknowns run in an assay. If more than one assay has been run for a particular study, then the mean intra-assay CVs for those assays should be averaged. - inter-assay CV - determines the between assay error (the error observed when the same sample is run in different assays). Determined by calculating the variation in values for samples run in every assay. Within a study can calculate the individual inter-assay CVs for each internal control and then average those numbers. Causes of variation: - intra-assay CV - generally is the result of the presence of unequal amounts of sample, tracer or antibody (i.e., poor pipetting, or incomplete mixing of sample or reagents), but also can be due to inconsistencies in counting or decanting. - inter-assay CV - caused by system-related problems like reagent instability, procedural variation or changes in standards (do not allow old standards to run out before making up new standards!). What is an acceptable level of error? - sample rejection - a level of error needs to be established that objectively determines when a sample needs to be re-analyzed. However, the amount of error tolerated is subjective and determined, in part, by how critically the data need to be interpreted. For example, the error rate would be lower in a human endocrinology laboratory where health status and potential treatments hinge on accurate measurements. Conversely, more error might be tolerated in assays conducted to define hormonal trends (i.e., the absolute values are not as important as the profile). - rules of thumb for defining acceptable levels of error 1. fixed percentage of the CV - often designated as 10% such that all samples with a CV >10% are re-analyzed. 2. assay rejection criteria - often subjective, but can involve exclusions based on control values falling within 2 SD of the mean of previous values, or a set proportion of sample CVs being below 10%.

Endocrine Manual Brown et al. 2005

11

120 100 80
The same 5% error in binding results in a greater %CV at each end of the curve

% B/TB 60
40 20 0 1 10 100 1000 10000

Standard Concentration
Proportional error: The CVs are higher and dose calculations are not proportional at the extreme ends of the standard curve, due to the non-linearity of the curve (see above figure). External quality control procedures: Commonly used in clinical laboratories to ensure that the quality of data are independent of the laboratory, which generated it. Involves analysis of samples provided by external sources.

Endocrine Manual Brown et al. 2005

12

Cortisol EIA Control Monitor Controls QCH %B 74.8 69.8 66.4 70.5 68.3 63.0 68.4 73.4 67.3 71.6 69.7 71.9 68.8 64.8 68.1 69.6 66.7 68.6 72.3 QCH Dose 64.4 57.4 58.6 57.1 58.6 68.5 59.8 44.8 61.3 50.0 52.1 54.4 62.7 53.4 53.3 47.4 50.7 59.6 50.1 QCL %B 53.7 48.0 46.6 47.8 44.8 44.5 49.1 50.7 48.2 47.0 45.7 46.3 48.7 42.0 46.3 43.0 40.3 49.8 48.4 QCL Dose 114.9 106.6 104.0 106.6 114.0 114.1 102.5 94.3 104.0 102.8 102.3 108.7 107.7 104.6 106.5 102.3 112.0 105.8 104.4

Standards 500.0 9.2 6.4 5.9 6.2 5.7 5.2 6.7 6.0 6.0 6.3 5.1 6.1 4.8 3.1 3.8 4.0 4.3 12.8 11.3 6.1 21.0 2.4 38.7 125.0 51.9 42.2 42.0 42.7 42.5 42.2 43.0 42.0 42.4 41.6 38.7 41.4 43.9 36.3 44.9 35.4 36.8 44.8 42.6 42.4 21.0 3.7 8.8 250.0 23.6 16.9 14.8 16.1 15.7 15.7 17.0 16.3 15.8 16.7 15.2 16.4 16.7 13.3 12.7 13.1 13.1 20.6 18.8 16.4 21.0 2.5 15.5

15.6

31.3 89.6 82.2 80.6 83.9 81.0 80.7 83.0 79.8 82.0 83.4 81.8 83.1 87.1 77.7 79.7 78.6 78.2 81.0 81.7 82.2 21.0 3.0 3.6

Date 4/22/02 6/27/02 6/28/02 6/29/02 6/30/02 7/1/02 7/1/02 7/1/02 7/1/02 7/3/01 7/3/01 7/3/01 7/3/01 7/19/02 7/19/02 7/19/02 7/19/02 7/31/02 7/31/02 10/23/0 2 10/23/0 2

Tech Sw Sw Sw Sw Sw Sw Sw Sw Sw Sw Sw Sw Sw Sw Sw Sw Sw Sw Sw Sw Sw

100.0 92.6 98.5 99.0 99.0 101.0 91.5 99.2 96.7 98.0 93.9 104.1 96.5 96.6 101.1 97.2 96.3 97.7

101.2 88.7 90.4 92.2 91.6 90.9 94.0 88.7 91.1 92.6 91.0 94.7 94.2 87.4 88.8 91.5 85.3 88.1 88.2

74.7 67.5 65.1 67.1 67.7 66.0 67.2 64.7 66.4 63.4 64.6 66.8 69.9 60.8 64.0 64.0 62.8 67.9 68.1

73.4 54.0 75.7 50.8 55.7 21.0 5.9 10.6 61.6 49.7

51.4 103.2 102.0 91.7 85.2 70.4 45.3 17.7 5.6 55.1 96.9 103.0 91.4 86.2 69.8 48.0 17.4 4.0 47.5 21.0 3.6 7.6 105.6 21.0 5.2 4.9 98.2 20.0 3.2 3.3 91.1 21.0 3.3 3.6 66.6 21.0 3.1 4.6

Mean 69.7 Count 21.0 Std Dev 3.2 CV 4.6 Mn +1SD 72.9 Mn-1SD 66.4 Min 63.0 Max

51.1 110.8 101.4 94.4 85.2 69.7 46.1 18.9 8.5 43.9 100.4 94.9 87.8 79.2 63.5 38.7 13.8 3.7 40.3 94.3 91.5 85.3 77.7 60.8 35.4 12.7 3.1 55.1 114.9 104.1 101.2 89.6 74.7 51.9 23.6 12.8

44.8 75.7 68.5

62.5

7.8

Endocrine Manual Brown et al. 2005

13

IX. LABORATORY IMMUNOASSAY VALIDATION PARALLELISM Definition: Parallelism is a way of determining if the assay is actually measuring what it should be measuring. It can also tell what dilution of sample to use for the assay. Samples to test should reflect the range of normal concentrations expected (i.e., estrous cycle and pregnancy, seasonal samples). Pool an equal amount of urine or fecal extract from each sample and dilute serially two-fold in assay buffer (neat, 1:2, 1:4, 1:8, 1:16, 1:32, 1:64, etc.). For example add 200 l of buffer into tubes labeled from 1:2 to 1:8192 - then take 200 l of the neat sample and mix with the 200 l in the 1:2 tube, vortex the 1:2 - then take 200 l out of the 1:2 and place in the 1:4 and so on. This will result in 200 l in each tube except the last dilution, which will have 400 l. Plot the % binding of samples by choosing an arbitrary concentration for the neat sample and halving the concentration for each dilution. If the sample curve parallels the standard curve the sample hormone is immunologically similar to the standard and can be measured proportionately.

100 80 60 Use 1:16 40 20 0 0.1 1 1:8 1:4 1:2 neat 10 Standard curve Parallel displacement 1:64 1:32

% B/TB

100

1000

Standard Concentration or Dilution


The best (most accurate) dilution to run samples is at ~50% binding (see above figure). The pool shows parallelism with the standard curve and is therefore valid for use in the assay. Samples should be run at a 1:16 dilution based on the binding inhibition observed at ~50%.

Endocrine Manual Brown et al. 2005

14

120 100 80 No displacement

% B/TB

60 40 20 0 0.1 1 10 Non-parallel displacement

Low concentration

Standard curve

100

1000

Standard Concentration or Dilution


In the graph above, samples that produced non-parallel or no displacement cannot be run in this assay system because they do not demonstrate immunoactivity of endogenous antigen similar to the assay standards. The sample with a low concentration of immunoactive antigen demonstrated limited parallelism, but this type of sample could only be run neat and there likely would be problems with limited detection within the working range of the assay (i.e., <80% binding). RECOVERY/ACCURACY CHECK Definition: A recovery tests for potential interference caused by substances contained within the biological sample that are independent of specific antigen-antibody binding. This test indicates the degree to which the measured concentration corresponds to the true concentration of a substance. Make a sample pool. It should have a low concentration of hormone (e.g., for progestagens use samples from the follicular phase). Spike aliquots of pooled sample (i.e., 100 l) with an equal amount (i.e., 100 l) from each standard. Analyze the spiked samples as unknowns in the assay. The sample pool also needs to be analyzed without added standard to determine the amount of endogenous (or background) hormone present. That will have to be subtracted out from each spiked sample.

Results: Amount Expected = (Concentration of standard spiked with / 2) Amount Observed = (Concentration observed from assay results minus background) % Recovery = (Amount Observed/Amount Expected)*100

Endocrine Manual Brown et al. 2005

15

Example:

Standard concentration (pg/well) 500.00 250.00 125.00 62.50 31.25 15.62 7.80 3.90 Endogenous/ Background 0.00

Amount added Amount Amount expected observed (pg/well) (pg/well) 250.00 235.48 125.00 119.07 62.50 65.85 31.25 42.52 15.63 30.10 7.81 23.45 3.90 19.98 1.95 18.54

Minus background (pg/well) 218.64 102.23 49.01 25.68 13.26 6.61 3.14 1.70

% Recovery 87.46 81.78 78.42 82.18 84.86 84.64 80.51 87.18

16.84

Plot Amount Expected vs. Amount Observed - conduct a linear regression (y=mx+b) analysis. Slopes > or < 1 suggests an over or under estimation of hormone mass, respectively.

Elephant Urine PdG Recovery

250 200 Amount 150 Observed 100 50 0 0 100 200 300 Amount Expected y = 0.8679x + 15.343 R2 = 0.9986

Endocrine Manual Brown et al. 2005

16

EXTRACTION EFFICIENCY

Definition: A way of defining how efficient or effective the extraction method is at extracting or pulling out metabolites of interest (steroid or protein hormones) from a specific matrix (urine, fecal, blood or saliva). Monitoring extraction efficiency also permits monitoring how consistent the extraction process is from sample to sample. Similar to recovery but samples are spiked before extraction. Spike each sample with:
Labeled hormone: ~2000 dpm/100 l of H or C radiolabeled steroid or Unlabeled (cold) hormone: (mass is dependant upon sensitivity of assay system) add enough mass to read at about 50% binding
3 14

Extract sample as per protocol.

After extraction: Determine Amount Observed:


Labeled hormone: aliquot 50 l from the final 1.0 ml extract to scintillation vial and count radioactivity. or Unlabeled hormone: analyze by RIA or EIA to determine concentration.

Determine Amount Expected:


Labeled hormone: aliquot 100 l of original stock of radiolabeled steroid to scintillation vial and count radioactivity. or Unlabeled hormone: dilute standard stock the sample the sample was spiked with to determine concentration.

Results:

Amount Expected = (expected minus background) Amount Observed = (observed minus background) % Extraction efficiency = (Amount Observed/Amount Expected)*100

Endocrine Manual Brown et al. 2005

17

X. BIOLOGICAL VALIDATION OF METHODS

It is crucial to demonstrate that hormonal measures accurately reflect the physiological events of interest. From a practical standpoint, it is unnecessary to determine the specific molecular structure of the hormones being monitored in each species. However, it is critical to prove that fluctuations in the hormonal metabolite being measured provide physiologically relevant information.
Validation based on physiological events

As examples, an ovarian cycle might be validated by comparing two independent measures of the same hormone in matched samples (i.e., fecal vs. urinary estrogen) or by comparing temporal hormonal excretion patterns with external signs of reproductive status (e.g., estrogens should increase with sex skin swelling, estrus, copulatory behavior). Similarly, showing a predicted rise and fall in progestin metabolite coincident with pregnancy onset and parturition, respectively, is solid evidence of the assays utility for assessing pregnancy status.
Validation using hormonal challenges

Administering a drug known to stimulate hormonal production is also useful for demonstrating a cause-andeffect relationship between its exogenous administration and the subsequent excretion of the target hormone. Typically, hormone challenges include gonadotropin releasing hormone (GnRH) to study pituitary hormones (LH, FSH) and subsequent androgen production (in males), or adrenocorticotropic hormone (ACTH) and cortisol secretion. This approach also clarifies the excretory lag-time between stimulation of an endocrine gland and the appearance of its hormonal metabolites in excreta.
General protocol for ACTH or GnRH challenges:

GnRH (e.g., Cystorelin) is typically administered at a dose of 1 5 g/kg body weight; ACTH (gel form preferred) is given at doses of 2-5 IU/kg. Drugs can be administered i.v. (preferable), i.m. or s.c. If blood collection is possible, samples should be collected as follows: -20 min, -10 min and 0 min, with 0 = time of hormone injection; 15 min, 30 min, 45 min, 60 min, 90 min, 2 hr, 3 hr, 4 hr, 6 hr and 8 hr post-injection. It is important that at least two pre-injection samples be collected, and that several are collected for at least 6 hr after injection. For fecal hormone validation, several pre-injection samples should be collected and every fecal sample for at least five days post-injection. For urinary hormone validation, several pre-injection samples should be collected (can start collecting the week before the test) and every urine sample for at least two days post-injection.

Endocrine Manual Brown et al. 2005

18

XI. HPLC FOR ANALYSIS OF METABOLITES

High performance (or pressure) liquid chromatography is a separation technique used to identify specific metabolites or components within a given sample. HPLC separates a sample into fractions, each of which is analyzed for crossreactivity in a given assay. The separation is performed when two phases are brought in contact, one phase being stationary (the column) and the other being mobile (a liquid). The sample mixture is forced through the column under pressure and undergoes a series of interactions between the stationary and mobile phases. Interactions exploit differences in the physical or chemical properties of the components within the sample. These differences govern the rate of migration of the individual components under the influence of the mobile phase moving through a column. Separated components emerge in the order of increasing interaction with the stationary phase. The least retarded component elutes first, the most strongly retained material elutes last. Selection of the appropriate HPLC method is governed by sample properties such as molecular weight, solubility and polarity. The most common method for the separation of steroids is reverse phase chromatography and is based on polarity [a non-polar stationary phase (a column packed with hydrocarbons) and a polar mobile phase (eg., methanol, water, acetonitrile and ethanol)]. The sample components are attracted to the surface of the adsorbent (the solid phase) with differing strength. Non-polar samples are attracted to the stationary phase and are retained, the more polar compounds elute first. As the gradient of the mobile phase is adjusted over time components within the sample are separated. As the polarity of the mobile phase increases the nonpolar samples begin to elude from the column.

HPLC of Fecal Estrone Metabolites 8000 Estrone (Fraction 63) 10000 8000 6000

6000 Radioactivity 4000 (cpm/fraction) 2000

Estrone-3Sulfate (Fraction 16)

Immunoactivity 4000 (pg/fraction) 2000 0

0 1 11 21 31 41 51 61 71 HPLC fraction
Unknown metabolite

Known Antigens Immunoreactivity on EIA

Endocrine Manual Brown et al. 2005

19

XII. IMMUNOASSAY TROUBLE SHOOTING

Some of the problems listed below are for EIA only. Those relevant to both EIA and RIA are designated by an asterisk *.
COLOR AND CURVE PROBLEMS

Color develops too quickly (or covers entire plate) Conjugate is too concentrated use higher dilution Curve will be flat on top This could also be the effect of too much first antibody Color develops too slowly (or not at all) Conjugate is too weak retitrate to lower dilution (add more) Curve will be flat on bottom This could also be the effect of too little first antibody Also, hydrogen peroxide could be bad (re-make fresh), diluted wrong or not added. Also see Loss of Binding Section Patchy color development See Poor Precision and High CVs section
LOSS OF BINDING

Decomposition of the antibody* Some antibodies are more stable than others. Best to store antibody frozen at a set dilution in a no frost-free freezer, or preferably an ultra-low freezer (especially for long-term storage of stocks). Store antibody upright (to decrease surface area exposed) in o-ring vials to ensure a tight seal. Antibody solutions should be prepared carefully (e.g., do not expose to excessive heat or shake vigorously). Most problems with loss of binding are NOT due to the antibody unless it is because not enough antibody was added. Poor label (or conjugate) characteristics* This is the most common factor causing low binding. Making fresh label will often correct low binding and improve color development. Care must be taken with these reagents; they provide the signal for the assay. i. Always store label at recommended temperatures. ii. Never store working label dilution for long periods of time. iii. It should always be made up just before use. iv. Never leave label on the bench at RT for excessive amounts of time. Ineffective separation Wash plates the recommended number of times and maintain consistency across the plate. Improper washing will lead to high CVs and loss of binding.

Endocrine Manual Brown et al. 2005

20

Reduced quality of assay reagents* It is important that buffers are made properly and often. Check buffer pH. Be sure that proteins like BSA are stored properly and not too old. Calculation error* Take care that all reagent calculations are correct. This is an easy place to make a simple mistake! Keep records of all calculations for each assay.
SHIFTED STANDARD CURVE

Parallel shift* Shift to the left - too much standard Shift to the right - too little standard Causes: - Inaccurate weighing of standards - check balance calibration - Inaccurate diluting of standards - check pipette calibration - Contamination of standard stock - make new standard stock - Changes in standard stock - due to evaporation, adsorption to storage vessel, etc. Non-parallel shift* Contaminated buffers - contamination with cross-reacting analytes or other compounds that interfere with binding.
HIGH NON-SPECIFIC BINDING*

Decomposition of label* Non-specific binding often increases as labels age or become damaged. Adherence of label to well or tube* Can be due to label decomposition or problems with buffer proteins that no longer prevent sticking. Incomplete removal of label* This can be caused by poor washing of the plate or decanting of assay tubes. Non-specific attachment of antibody Unsuitable blocking buffer used (needs to be re-made) or omission of blocking buffer (forgot to add it).
POOR PRECISION AND HIGH CVs*

Human error* Inconsistent pipetting, washing etc. The key is to be consistent. Avoid bubbles in pipet tips. Incomplete mixing of samples or other reagents All frozen samples must be thoroughly, but gently, mixed after thawing. Never shake samples or assay reagents vigorously. Equipment failure* Check that all wells are being washed evenly. Pipets are fundamentally important to the accuracy of the assay. They should be checked on a regular bases for precision and accuracy of delivery volumes*. Poor handling of the plates Clean the bottom of plates with a kimwipe before inserting into the reader. Film, dirt or fingerprints on the bottom of the plate could interfere with optical density readings resulting in poor CVs.

Endocrine Manual Brown et al. 2005

21

Avoid stacking plates. Keep separated. Always keep plates sealed with plate covers during incubation steps. Always use the same procedure for addition of reagents.

Using the wrong plates Always use the recommended plate for a particular assay. Never use a tissue culture grade plate for EIA; it will result in high variability. Water quality* This can be a major problem for the daily functioning of assays within a laboratory as well as for standardization of assays across laboratories even when identical reagents are used. Laboratory Glassware* All glass and plastic should be cleaned and rinsed well in distilled water. This avoids the introduction of contaminants or adverse pH conditions into the assay. An enzymatic type detergent (such as Terg-A-Zyme) should be used to wash dishes. Timing of steps* Individual steps should be timed accurately. For example for a 1-hour incubation step, no more than 5 minutes either way should be tolerated. Temperature* Temperature can have an impact on assay development. Make a note of temperature and its variation during the year, this may explain variation in results at different times.

Endocrine Manual Brown et al. 2005

22

XIII. SAMPLE COLLECTION/STORAGE METHODS

It is very important that all samples be properly labeled with the animals name or studbook/identification number, facility, and date.
BLOOD:

When collecting multiple samples per day, label the time. This is especially important for hormone challenges, like ACTH and GnRH. After blood has been collected and centrifuged, pour serum into the labeled storage tube. Leave room in the tube for expansion of sample during freezing (e.g., put 4 ml into a 5-ml vial). Place samples upright into storage box and freeze at -20C. Store samples in the box from left to right and front to back (see box below). Place the first sample in space #1 and repeat for each new sample added. This way, when processing samples, they are already organized and in order by date and time. Remember to keep all samples frozen until analysis. Label the outside of the storage box with the name of the animal, species (if necessary), the location of the animal, the matrix (urine, serum, fecal extract), and the dates of the first and last sample in the box. For example: Shanthi, Asian Elephant, National Zoo, urine, 1 Oct 00 - 20 Nov 00.

Sample storage box: 91 81 71 61 51 41 31 21 11 1 2 3 4 95 85 75 65 55 45 35 25 15 5 6 7 8 9 100 90 80 70 60 50 40 30 20 10

Endocrine Manual Brown et al. 2005

23

URINE:

Label collection tube with animals name, date, and time collected. If necessary, record if the sample may have been contaminated with feces, water, etc. Whenever possible, centrifuge sample and decant supernatant to remove debris. Pour urine sample into labeled tube and place in storage box. Leave room in the tube for expansion of sample during freezing (e.g., put 4 ml into a 5 ml vial). Store sample in freezer at -20C. Store samples as described previously. If storing samples at RT or in the refrigerator (for up to a month) instead of freezing, add 10% ethanol to each tube as a preservative. Thoroughly clean syringes or cups used to collect urine samples to prevent cross-contamination.

FECES:

Place feces in collection bag or tube labeled with animals name, date, and time (if relevant) and store at -20C. For fecal extracts, label storage tube with animals name, date, time, and the extraction medium. For example: Shanthi, 1 Oct 00, 0800 h, neat extract MeOH. If making dilutions from the extract and the dilutions will be stored as well, label the storage tube with the animals name, date, time, and the dilution. Remember, dilutions are always made in assay buffer. Place fecal extract tubes in storage boxes as described previously and store at -20C. Fecal extracts are in alcohol so they will not freeze.

FECAL DILUTIONS

For fecal extracts and urine samples, dilutions often have to be made, especially for extracts stored in alcohols. The appropriate dilution to use is determined from the parallelism curve. Dilutions are always made with assay buffer. Dilutions are always stated as 1 to a number. For example: 1:100 (1 + 99) means one part sample to 100 total parts volume. Once fecal extract samples have been diluted in buffer, they can be frozen indefinitely until analysis.

Endocrine Manual Brown et al. 2005

24

XIV. HORMONE EXTRACTION METHODS

Definition: Extraction is a method by which components of interest in a sample are isolated, removed or concentrated, making it free of interference from other particulates found within the matrix (fecal, urine, blood or saliva). This generally refers to steroids. For most assay systems, free steroids must be extracted from the sample matrix. A few systems have been developed to analyze unextracted samples (e.g., commercial RIA kits). The extraction method used is dependent on the properties of the component of interest. For more specific extractions (eg. pulling in a specific group of steroids, or removing proteins or lipids from a sample) varying solvents and/or ratios of two or more solvents can be used.
BLOOD SERUM OR PLASMA

Ether extraction is most commonly used. Diethyl ether is used for progestagens; ethyl ether is used for estrogens and androgens. Standard protocol involves extracting with a 10:1 volume of ether: sample by vortexing for 1 minute followed by snap freezing in liquid nitrogen or dry ice/acetone. The ether supernatant is dried and the sample reconstituted in assay buffer, vortexed for 1 min and stored frozen (-20C) until analyzed.

URINE

Ether can be used for gonadal steroids similar to blood serum/plasma extractions. For corticoids, dichloromethane is very effective. For that method, urine (0.5 ml) is combined with 1 ml dichloromethane in a 12 x 75 mm polypropylene tube, capped tightly, shaken gently for 10 min and centrifuged (1500 x g) for 5 min. The lower dichloromethane fraction is removed by aspiration using a Pasteur pipet and placed into a glass 12 x 75 mm tube. Six hundred are then transferred to another glass 12 x 75 mm tube using a positive displacement pipet and dried under air. Samples are reconstituted in assay buffer, vortexed for 1 min and stored frozen (-20C) until analyzed.

CONJUGATED STEROID ANALYSIS

Steroid conjugates (sulfates or glucuronides) can be assayed directly using antibodies that crossreact with conjugates. Conjugated steroids can be assessed indirectly after enzyme hydrolysis (e.g., sulfatase, glucuronidase or snail juice, Helix pomatia, which contains both glucuronidase and sulfatase activity) and assaying the resulting free steroids. Extract urine, serum or fecal extracts (resuspended in 0.5 ml buffer) with 10 volumes of diethyl ether to separate water-soluble from ether-soluble forms. Hydrolyze residual aqueous samples diluted 1:1 in 0.5 ml in 0.1 M acetate buffer (pH 5.0) with 50 l -glucuronidase/aryl sulfatase (20,000 Fishman U/40,000 Roy U, respectively; Boehringer Mannheim Corp., Indianapolis, IN) at 37C for 24 hours. Samples are then extracted with 10 volumes of diethyl ether to separate enzyme-hydrolyzable (organic phase) from non-hydrolyzable (aqueous phase) forms.

Endocrine Manual Brown et al. 2005

25

DRY AND WET WEIGHT FECAL EXTRACTION BOILING METHOD

1. Feces can be dried using a lyophilizer, savant rotary evaporator or conventional oven (~50C to 95C oven temps have been reported for several hours or until dry; i.e., weight no longer changes). Solar ovens are not recommended due to potential steroid alteration by UV light. Drying times will vary for each technique and even among individual or species samples. 2. Weigh out feces in numbered 16x125 mm glass tubes. Record weight of each sample. 3. The following weights are suggestions: Dry: Herbivores Weigh out 0.1 g (+/- 0.01) of dry powdered feces Carnivores Weigh out 0.2 g (+/- 0.02) of dry powdered feces
Wet: Herbivores and Carnivores Weigh out 0.5 g (+/- 0.01) of wet feces

4. If monitoring extraction efficiency, add appropriate amount of tracer or unlabeled hormone to each tube (see below). 5. Add 4.5 ml of ETOH and 0.5 of dH2O (90% ETOH) to each tube and vortex briefly. 6. Boil tubes in boiling water bath (96 for 20 minutes. Keep rack from touching the bottom to prevent ) splattering of tube contents. Add 100% ETOH as needed to keep from boiling dry. 7. Bring the volume of the extract up to approximately pre-boil levels with 100% ETOH. 8. Centrifuge the samples at 2500 rpm for 20 minutes, making sure the centrifuge is balanced. 9. Pour off the extracts into a second set of identically labeled 16x125 mm tubes. 10. Add 4.5 ml ETOH and 0.5 ml of dH2O to the original tubes containing the fecal pellets and vortex each tube for 30 seconds. 11. Centrifuge these tubes at 2500 rpm for 20 minutes. 12. Pour off the extract into the second set of tubes containing the first extract. 13. Dry down the second set of tubes under air in a warm water bath. 14. Re-suspend the dried down extracts in 3 ml ETOH, vortex and dry down under air in a warm water bath. 15. Bring up in 1 ml of MEOH or dilution buffer, vortex briefly, sonicate for 15 minutes.
16. Pour off extracts into labeled 12x75 mm plastic tubes, if using MeOH dry down extract under air.

Endocrine Manual Brown et al. 2005

26

FECAL EXTRACTION VORTEXING METHOD

1. Steps 1-4 same as above. 2. Add 4.5 ml of ETOH and 0.5 of dH2O to each tube and vortex briefly. 3. Load samples into a rack shaker. Shake at room temperature for 4 hours or at 4C overnight (these are suggested times). 4. Vortex for 30 min. Most hormone is extracted in the first 5 min, but some species may take longer. 5. Centrifuge at ~2500 rpm for 20 min.
FECAL EXTRACTION SHAKING METHOD

1. Steps 1-4 same as above. 2. Load samples onto a multitube vortexer. 3. Vortex each sample at a speed of ~60-70 (fast enough so a good vortex is created; not so fast that the tubes work their way up out of their place), with 1 pulse/sec. 4. Vortex for 30 min. Most of the steroids are probably extracted within 5 min, but samples from some species may take longer due to consistency differences. 5. Centrifuge at ~2500 rpm for 20 min. 6. Follow Steps 9-16 as above.

Endocrine Manual Brown et al. 2005

27

EXTRACTION EFFICIENCY PROTOCOL Use of radioactive tracer (most efficient and accurate method)

1. Dilute H3 or C14 labeled hormone to about 2000 dpm/100

l. l to two scintillation vials with

2. Add 100 l of tracer (H3 or C14) to all tubes. At the same time add 100 same repeater pipet as that used to add tracer to samples. 3. Extract the sample as described previously.

4. Take 100 l from each sample extract (the 1 ml MeOH extract from step 14 of the extraction protocol) and add to scintillation vials. Do in singlicate, not duplicate. 5. Add 3 ml of scintillation fluid to all vials, including the two vials with tracer. Create 2 blank vials and add only 3 ml of scintillation fluid. 6. Cap all vials firmly and invert to mix the fluid and set aside for an hour. 7. Determine DPM in a Beta Counter. 8. Calculations: Average your blank values (zero values) and subtract this from everything, including your totals. Average totals. Sample x 10 (because is a tenth of the total sample volume)/averaged total value = multiply by 100 to get a percentage. Between 80 and 100 is acceptable. If the percent recovery is over 100 the quench needs to be checked because the color of the extract may be interfering with the counters ability to read the sample. If the sample is too dark it needs to be diluted out by adding more scintillation cocktail when you run the next recovery.
Use of unlabeled hormone (requires two extractions per sample)

1. Dilute cold steroid in assay buffer to a concentration ~10 times the value of the 50% binding standard concentration at the l concentration used in each assay (i.e., 50 l for most assays). This concentration is an estimate. Because samples are diluted before analysis, the concentration added may need to be adjusted. Goal should be to spike samples with enough steroid so that the value falls within the standard range. Best results will be obtained using low concentration samples so that the endogenous concentration falls near the 80% binding portion of the curve. 2. Add cold steroid dilution to all tubes (i.e., 50 l for most assays) (i.e., spiked sample). Also, set aside duplicate sample tubes for each sample with no added hormone (to determine endogenous concentration in unspiked sample) (i.e., unspiked sample). 3. Extract samples as describe previously. 4. Dilute samples as determined by parallelism tests and analyze as per assay protocol. 5. Calculations: Average the concentration for each paired set of samples (one extracted with added steroid, one extracted with no added steroid). Subtract the value of the unspiked sample from the spiked sample and determine the difference. Calculate the percentage difference for the recovery value (the difference between spiked and unspiked sample).
Use of repeated extraction to determine extraction consistency

Endocrine Manual Brown et al. 2005

28

1. While not a measure of extraction recovery per se, extracting a large number of duplicates of individual samples can give an indication of how consistent the extraction process is. Thus, even if the actual recovery is unknown, if the extraction consistency is good (<15-20%), the data generated will be okay. 2. This procedure should be done occasionally (~1 trial per month) to ensure continued precision. 3. Take 5 individual dried fecal samples, mix well and split into 20 subaliquots. Extract each subaliquot and calculate the %CV among aliquots within each sample.

Endocrine Manual Brown et al. 2005

29

Fecal Extraction Sheet


Species: Date: Sex: ID: Zoo:

Sample 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49

DATE

WEIGHT

Sample 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98

DATE

WEIGHT

Sample 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147

DATE

WEIGHT

Endocrine Manual Brown et al. 2005

30

XV. CALCULATING EIA RESULTS READING THE PLATE

Since the product of EIA is color, it can be read in two ways: 1) by eye inspection; or 2) by using a spectrophotometer. Reading plates by eye is usually only used for positive/negative type results. The product of the substrate catalysis by enzyme is measured by transmitting light of a specific wavelength through the product and measuring the amount of light adsorption by a plate reader (i.e., optical density). Since different products can be produced in EIAs, the correct filter for the detection of the wavelength must be used.

CALCULATING RESULTS FROM OPTICAL DENSITY (OD)

There are no set rules on how to set up a plate; it is a matter of choice. We run plates by moving down columns (standard curve in duplicate zeros; standards S2-S10; controls, C1-C2; samples, T1-T26; standard curve in singlet to account for any time lag in loading the plate). S= Standard C= Control T= Test Sample 1 2 3 4 5 6 7
A B C D E F G H

10

11

12

Blank Zero S5 Blank Zero S5 S2 S6 S2 S3 S3 S4 S4 S6 S7 S7 S8 S8

S9

T1

T5 T5 T6 T6 T7 T7 T8 T8

T9

T13 T17 T21 T25 S5

S9 T1 S10 T2 S10 T2 C1 C1 C2 C2 T3 T3 T4 T4

T9 T13 T17 T21 T25 S6 T10 T14 T18 T22 T26 S7 T10 T14 T18 T22 T26 S8 T11 T15 T19 T23 Zero S9 T11 T15 T19 T23 S2 T12 T16 T20 T24 S3 T12 T16 T20 T24 S4 S10 Zero Zero

AVERAGE BLANK VALUE:

This is the average OD of both blank wells (background or non-specific binding) This average is then removed from every other well on the plate

Endocrine Manual Brown et al. 2005

31

DATA MATRIX/TABLE : OD

These are the final OD readings from the plate reader after the background has been removed. The printout will identify which OD value corresponds to which well.

Example: Well A3 OD equals 0.722 on print out 1 A B C D E F G H 2 3 4 5 6 7 8 9 10 11 12

Blank Blank

0.722

Results:

To determine % specific binding, calculate the average OD of the zero wells


1 A B C D E F G H 2 3 4 5 6 7 8 9 10 11 12

.831 .928

.864 .860 .877

Endocrine Manual Brown et al. 2005

32

Example: (Well A2, B2, 11E, 12G, 12H)/5 From printout - (0.831 + 0.928 + 0.864 + 0.860 + 0.877)/5 = 0.872

0.872 is the denominator by which all other OD values are divided


1 A B C D E F G H 2 3 4 5 6 7 8 9 10 11 12

.857

Example: OD from Well E2 equals (0.857/0.872) * 100 % = 98.2%

Calculate the % binding for each of the standard wells.


1 A B C D E F G H 2 3 4 5 6 7 8 9 10 11 12

82 82 105 70 103 68 98 99 92 92 55 52 39 38

26 25 15 14

81 68 52 35 24 94 93 94 15

Take the average % binding of the standards that have been run in triplicate.

Example: Standard 10 which is 1000 pg/well is found in wells C4, D4 and F12 From print out (15 + 14 + 16)/3 = 15%

Endocrine Manual Brown et al. 2005

33

Now plot the standard curve.

120 100 80 %B/TB 60 40 20 0 1 10 100 1000 10000 Standard Concentration (logrithmic scale)
Calculate the % binding of all controls and test samples
1 A B C D E F G H 2 3 4 5 6 7 8 9 10 11 12

79 74 75 76 44 43 81 81 77 73 78 77

80 78 79 78 76 73 70 67

73 64 71 71 73 71 40 43

68 59 71 69 64 56 69 69

67 63 65 63 65 62 76 76

70 63

121 112

108 115 109 108 106 106 108 109

Endocrine Manual Brown et al. 2005

34

Calculate dose for each control and test sample by extrapolating data from standard curve

120 100 80 % B/TB 60 40 20 0 1 10 100 1000 10000 Standard Concentration (logrithmic scale)
Example: Test sample one or T1 was placed into Well A5 and Well A2. The percent binding was calculated to be 79% and 74%, respectively. The average % binding would be 76%. The concentration at 76% is 42.85 pg/well. Results are converted to concentration/ml of sample. Example: 42.85 pg/well is equal to 42.85 pg/50 l The 50 is much was loaded into the well, for the cortisol assay this is 50 l/well.
2nd 1st

Thus, 42.85 pg/50 l = 0.857 pg/l 0.857 pg/l * 1000 (1 ml) = 857 pg/ml 857 pg/ml/1000 (pg to ng) = 0.857 ng/ml
CONVERTING DATA FROM FECES Example: Need weight of feces originally weighed out for extraction (e.g., 0.5 g) Final volume from the extraction (e.g., 1 ml) From the assay calculate the mass (e.g., pg/well to ng/ml.say 120 ng/ml) Dilution factors need to be calculated into the data (e.g., samples ran at a 1:10 then 120 * 10 = 1200 ng/ml)

Thus, 1200 ng/0.5 g = x ng/1g of feces = 240 ng/g of feces

Endocrine Manual Brown et al. 2005

35

CONVERTING DATA FROM URINE Example: From the assay calculate the mass (e.g., pg/well to ng/ml.e.g., 20 ng/ml) Dilution factors need to be calculated into the data (e.g., samples ran at a 1:10 then 10 * 20 = 200 ng/ml) Then divide the sample value by the creatinine value (e.g., 0.182 mg/ml creatinine)

Thus, 200 ng/ml divided by 0.182 mg/ml = 1098.9 ng/mg creatinine


TIPS FOR READING EIA PLATES

Clean bottom of plate before reading Make sure the right filter is used to read the plate Get print out of ODs Remove average background ODs from all other OD values Calculate average zero OD value Use this to calculate % binding of all other wells - (OD of each well/ zero OD average value) *100% Plot the standard curve concentration (x axis - log scale) vs % binding (y axis - linear scale) Average % bindings for each sample (controls and test samples) Extrapolate concentrations based on % binding Convert data to a per ml or per gram mass concentration (Example: pg/well to ng/ml)

Endocrine Manual Brown et al. 2005

36

XVI. ASSAY PROTOCOLS Note: Throughout the Assay Protocol section, reference to room temperature means 65 - 80 (22 - 26 F C). Referral to freezing of samples means -4 (-20 or colder. F C) CREATININE ASSAY

Definition: Creatinine is a breakdown product of muscle protein that is excreted in urine at a constant rate. It is a way to measure how concentrated a urine sample is and whether or not a certain sample is viable. For instance, if it contains too much water and thus mass within the sample is too dilute to measure, it is not a viable sample. Thaw all samples to be analyzed. Creatinine can degrade so samples should be thawed once or kept cold. It is best to run the creatinine assay after the first thaw of the sample, but as long as the sample is kept cold after thawing it can be refrozen and run at a later time.
PROTOCOL FOR CREATININE ASSAY - per plate 1. STANDARDS Standard values used are 100, 50, 25, 12.5, and 6.25 g/ml Dilute top standard stock (Sigma 925-11; 10 mg/dl or 100 g/ml, 4C) serially 2-fold using 200 l stock plus 200 l assay buffer or tap water and mix well Use same buffer or tap water as the zero standard (Note: water quality is not critical) 2. SAMPLES Dilute samples to appropriate amount (1:5 - 1:100 in buffer or water) 3. PLATE LOADING Use Dynatech plates (Immulon 4 Flat Bottom Plates Cat # 0110103855) Add 50 l per well of standard and sample in duplicate according to plate map Speed of addition is unimportant as this is not a binding assay Start at A1 and go down each set of columns Pipet all solutions in this order Avoid splashing or touching the samples in the wells Add 50 l of tap water to each well using the repeater pipet Add 50 l per well 0.75 N NaOH Add 50 l per well 0.4 N picric acid using the repeater pipet Shake plate briefly to mix (by tapping) and incubate at RT for 30 minutes 4. PLATE READING Wipe bottom of plate to make sure it is clean Read at 490 nm 5. ASSAY DILUTION/VALUE CUTOFFS Avoid running samples at <1:5 or >1:100 dilution Any sample with a creatinine value of <0.1 mg/ml is too dilute and should not be used

Endocrine Manual Brown et al. 2005

37

Creatinine Assay Template


ASSAY DATE SPECIES ANIMAL ID DILUTION 1 A B C D E F G H 0 0 6.25 6.25 12.5 12.5 25 25 2 50 50 100 100 3 4 5 6 7 8 9 10 11 12

Endocrine Manual Brown et al. 2005

38

CHECKERBOARD TITRATION FOR EIA

Definition: A checkerboard titration is used to determine the appropriate concentrations of enzyme conjugate tracer and first antibody to use in an EIA. Different concentrations of antibody are run horizontally, whereas tracer dilutions are run vertically along the plate (see template). A high and zero standard is run at each level. The ideal concentration of antibody and conjugate is one that provides good distinction between high and zero standards, at the highest dilutions possible. The following is an example of a Checkerboard Titration for the EC R522-2 assay. Each assay will require testing different concentrations of reagents. Follow these steps along with the titration plate map:
Day 1:

Prepare a 1:100 dilution of the EC R522-2 Ab by adding 20 l of stock to 2 ml of coating buffer, label this tube Working Ab You will now prepare several Ab concentrations. The directions are as follows: Prepare a 1:15,000 by adding 13.33 l of Working Ab to 1986.7 l Coating Buffer (you can do this precisely by adding 2 ml of coating buffer to a tube, remove 13.33 l of the coating buffer with a 100 l pipet, and using the same pipette tip take out 13.33l of the 1:100 Working Ab and add it to the tube containing the buffer. This step can be followed for the following Ab dilutions and the HRP dilutions in step 9, just adjust the amounts accordingly). Prepare a 1:20,000 by adding 10 l of working Ab to 1990 l of Coating Buffer. Prepare a 1:30,000 by adding 10 l of working Ab to 2990 l of Coating Buffer. Prepare a 1:40,000 by adding 10 l of working Ab to 3990 l of Coating Buffer. Prepare a 1:50,000 by adding 10 l of working Ab to 4990 l of Coating Buffer.

In this step you will coat your plate with the Ab dilutions you made in step 2 according to the plate map: Coat columns 1 & 2 with 50 l of the 1:15,000 dilution in each well. Coat columns 3 & 4 with 50 l of the 1:20,000 dilution in each well. Coat columns 5 & 6 with 50 l of the 1:30,000 dilution in each well. Coat columns 7 & 8 with 50 l of the 1:40,000 dilution in each well. Coat columns 9 & 10 with 50 l of the 1:50,000 dilution in each well. For columns 11 & 12 add 50 l of Coating buffer to each well (do not add Ab to columns 11 & 12). Cover with acetate plate sealer and leave overnight at 4C.
Day 2:

Wash the plate as usual. Add 50 l EIA buffer to all wells of the plate, cover with plate sealer, and let plate set at room temperature for 2 - 5 hours. You will need at least 3mls of top standard (200 pg/well, see EC (EC R522-2) Stock Preparations of the EC R522-2 protocol on how to make this up) and EIA buffer for the plate (you will not need to dilute the standard). For this procedure it is best to prepare a fresh batch of HRP working stock. Add 20 l of HRP stock to 980 l EIA buffer. Prepare several HRP concentrations to test out. The directions are as follows (keep all solutions cool while: For the 1:10,000 add 20 l of HRP working stock to 1980 l of EIA buffer. For the 1:15,000 add 13.33 l of HRP working stock to 1986.7 l of EIA buffer. For the 1:20,000 add 10 l of HRP working stock to 1990 l of EIA buffer. For the 1:25,000 add 12 l of HRP working stock 2988 l of EIA buffer.

Loading the Plate:

Endocrine Manual Brown et al. 2005

39

Add 20 l of EIA buffer to each well in rows A, C, E, and G. Add 20 l of top standard (200 pg/well) each well in to rows B, D, F, and H. Add the respective HRPs to the plate (following the plate map): 50 l of HRP 1:10,000 to each well in rows A & B. 50 l of HRP 1:15,000 to each well in rows C & D. 50 l of HRP 1:20,000 to each well in rows E & F. 50 l of HRP 1:25,000 to each well in rows G & H. Let plate incubate for two hours at room temp. Wash plate and add substrate as you usually do when running the EC assay. After 30 minutes read the plate.

Interpreting the results:

1. Ideal Ab and HRP concentrations are those that produce ODs of the zeros in rows A, C, E, and G between 0.8 and 1.0. 2. Average all ODs for the 0s and Top Standards for each Ab and HRP dilution set. For example: average the 0s that are in wells A1 and A2 and the top standards in B1 and B2 (A1, A2, B1 and B2 make up the block of wells that are included in the Ab dilution of 1:15,000 and HRP dilution of 1:10,000). 3. Divide the top standard average of a dilution set by the 0 average of the same dilution set to get the displacement number. Calculate the displacement number for all the Ab and HRP dilution sets that have 0s with ODs between 0.8 and 1.0. 4. The Ab and HRP dilution set with the highest displacement number is the Ab and HRP dilution set to use for the assay.

Endocrine Manual Brown et al. 2005

40

Checkerboard Titration Plate Map Assay Species Date Animal ID Ab CONCENTRATIONS 1:15,000 1:20,000 1 2 3 4

1:30,000
5 6

1:40,000
7 8

1:50,000
9 10

0
11 12

1:10,000

HRP CONCENTRATIONS

High 0 Standard

1:15,000

High 0 Standard

1:20,000

High 0 Standard

1:25,000

High 0 Standard

Endocrine Manual Brown et al. 2005

41

CORTISOL EIA Day 1: 1. Plate coating Use NUNC Maxisorb plates Add 50 l antibody stock ( 1:85, -20C) to 5 ml coating buffer (working dilution 1:8500) Add 50 l per well of antibody solution to plate. do not coat column 1 - start at A2 and go down each column (see plate map). Pipet all solutions in this order. Tap plates gently to ensure that coating solution covers bottom of well Label, cover with acetate plate sealer and leave overnight (no less than 12 hrs) at 4C. Day 2: 2. Standards Standard values used are: 1000, 500, 250, 125, 62.5, 31.2, 15.6, 7.8 and 3.9 pg/well. Dilute standard working stock (20 ng/ml or 1000 pg/well) serially (2-fold) by using 250 l stock plus 250 l EIA buffer. 3.Samples/controls Dilute urine or fecal samples in dilution buffer to appropriate dilution. Prepare High and Low control 4. HRP Cortisol HRP working dilution is 1:20,000. Add 25 l of HRP working stock to 5 ml EIA buffer to make the working dilution (keep this solution cool) 5. Plate washing Wash the plate five times with wash solution. Blot the plate on paper towel to remove excess wash solution. 6. Plate loading Pipet 50 l of standard, control and samples per well as quickly and accurately as possible, according to plate map. Add 50 l of diluted cortisol HRP (step 4) to all wells that contain standard, control, or sample. Avoid splashing. No more than 10 minutes should pass during this process Cover plates with acetate plate sealer and incubate at room temperature for exactly 1 hour. 7. Plate washing Wash the plate five times with wash solution. Blot the plate on paper towel to remove excess wash solution. Plates are fairly stable at this point and can be left upside down on bench top until all plates are washed (no more than 20 minutes)

Endocrine Manual Brown et al. 2005

42

8. Substrate Prepare ABTS substrate immediately before use (within 20 min). Combine 40 l 0.5 M H2O2, 125 l 40 mM ABTS and 12.5 ml substrate buffer, and mix well. Add 100 l ABTS substrate to all wells that contain standard, control, or sample. Cover with plate sealer and incubate at room temperature with shaking. Plate color development will vary based on age of HRP and/or Ab, but should be no greater than one hour. 9. Plate reading Optical density (OD) of 0 wells should read 1 or less. Optimal readings for 0 wells: > 0.7 to < 1 OD. Read at 405 nm (reference 540 nm).
CORTISOL STOCK PREPARATIONS per plate

1. Antibody Dilute cortisol R4866 at a dilution of 1:85 by adding 24 l of stock to 2 ml of coating buffer. Aliquot 300-400 l into O-ring vials and store at -20C. Store antibody stock at -80C. 2. HRP Conjugate Dilute cortisol-horseradish peroxidase (HRP) 1:100 by adding 25 l of stock to 2.475 ml EIA buffer for a working stock and store at 4C. Store HRP stock at -80C. 3. Standards Weigh out 1 mg cortisol (Sigma Diagnostics) and add to 1 ml ETOH for a 1 mg/ml primary stock. Dilute 1 mg/ml primary stock 1:100 by adding 100 l to 10 ml ETOH for a 10 g/ml secondary stock. Dilute 10 g/ml secondary stock 1:500 by adding 100 l to 49.9 ml of EIA Buffer for a 20 ng/ml (1000 pg/well*) working stock. Aliquot working stock and store all stocks at -20C. * a well is equal to 50 l, the amount used in the assay. 4. Controls Use urine or extracted fecal samples with a high corticoid levels to make controls. Make a pool of high corticoid level urine or extracted feces (~20 ml). Serially dilute pool and run on assay. Find the dilutions that bind at ~70% and ~30%. Use the pool to make up two separate stocks for low and high controls using the dilutions that bound at 70% and 30% respectively. Make up enough controls to run on at least 500 assays (for this you may need more than the 20 ml used for the pool. Any species will do so long at the urine has high corticoid levels.)

Endocrine Manual Brown et al. 2005

43

CORTISOL EIA Template


ASSAY DATE SPECIES ANIMAL ID DILUTION 1 Blank A 62.5 B 3.9 C 250 D 7.8 E 3.9 F 15.6 G 15.6 H 0 250 C2 7.8 0 1000 125 C1 0 500 62.5 1000 125 2 0 3 31.2 4 500 5 6 7 8 9 10 11 12 31.2

Endocrine Manual Brown et al. 2005

44

PREGNANE (CL425) EIA Day1: 1. Plate Coating Use NUNC Maxisorb plates. Add 25 l antibody stock (1:50, -20C) to 5 ml coating buffer (working dilution 1:10,000). Add 50 l per well of antibody solution to plate. do not coat column 1 - start at A2 and go down each column (see plate map). Pipet all solutions in this order. Tap plates gently to ensure that coating solution covers bottom of well. Label, cover with acetate plate sealer and leave overnight (no less than 12 hrs) at 4C. Day 2: 2. Standards Standard values used are: 200, 100, 50, 25, 12.5, 6.25, 3.12, 1.56 and 0.78 pg/well. Dilute standard working stock (4 ng/ml or 200 pg/well) serially (2-fold) by using 250 l stock plus 250 l EIA buffer. 3. Samples/controls Dilute urine or fecal samples in dilution buffer to appropriate dilution. Prepare High and Low controls. 4. HRP Pregnane HRP working dilution is 1:40,000. Add 30 l of HRP working stock to 6 ml EIA buffer to make the working dilution (keep this solution cool). 5. Plate washing Wash the plate five times with wash solution. Blot the plate on paper towel to remove excess wash solution. 6. Plate loading Pipet 50 l of standard, control and samples per well as quickly and accurately as possible, according to plate map. Add 50 l of diluted Pregnane HRP (step 4) to all wells that contain standard, control, or sample. Avoid splashing. No more than 10 minutes should pass during this process Cover plates with acetate plate sealer and incubate at room temperature for exactly 2 hours. 7. Plate washing Wash the plate five times with wash solution. Blot the plate on paper towel to remove excess wash solution. Plates are fairly stable at this point and can be left upside down on bench top until all plates are washed (no more than 1 hour).

Endocrine Manual Brown et al. 2005

45

8. Substrate Prepare ABTS substrate immediately before use (within 20 min). Combine 40 l 0.5 M H2O2, 125 l 40 mM ABTS and 12.5 ml substrate buffer, and mix well. Add 100 l ABTS substrate to all wells that contain standard, control, or sample. Cover with plate sealer and incubate at room temperature with shaking. Plate color development will vary based on age of HRP and/or Ab, but should be no greater than one hour. 9. Plate reading Optical density (OD) of 0 wells should read 1 or less. Optimal readings for 0 wells: > 0.7 to < 1 OD. Read at 405 nm (reference 540 nm).
PREGNANE STOCK PREPARATION per plate

1. Antibody Dilute monoclonal CL425 at a dilution of 1:50 by adding 100 l of stock to 4.9 ml of coating buffer. Aliquot 300-400 l into O-ring vials and store at -20C. Store Antibody stock at -80C. 2. HRP Conjugate Dilute progesterone-3CMO-horseradish peroxidase 1:200 by adding 25 l of stock to 4.975 ml EIA buffer for a working stock and store at 4C. Store HRP stock at -80C. 3. Standards Weigh out 0.5 mg progesterone (Sigma Diagnostics Cat. # P 0130) and add to 5 ml ETOH in a scintillation vial for a 100 g/ml primary stock solution Dilute 100 g/ml (100 000 ng/ml) primary stock 1:100 by adding 40 l to 4 ml ETOH for a 100 ng/ml secondary stock. Dilute 100 ng/ml secondary stock 1:2500 by adding 200 l to 49.8 ml of EIA Buffer for a 4 ng/ml (200 pg/well*) working stock. Aliquot working stock and store all stocks at -20C. *a well is equal to 50 l, the amount used in the assay. 4. Controls Use urine or extracted fecal samples with a high progestin levels to make controls. Make a pool of high progestin level urine or extracted feces (~20 ml). Serially dilute pool and run on assay. Find the dilutions that bind at ~70% and ~30%. Use the pool to make up two separate stocks for low and high controls using the dilutions that bound at 70% and 30% respectively. Make up enough controls to run on at least 500 assays (for this you may need more than the 20 ml used for the pool. Any species will do so long at the urine has high progestin levels).

Endocrine Manual Brown et al. 2005

46

PREGNANE EIA Template


DATE ANIMAL ID DILUTION 1 Blank A 12.5 B 0.78 C 50 D 1.56 E 0.78 F 3.12 G 3.12 H 0 50 C2 1.56 0 200 25 C1 0 100 12.5 200 25 2 0 3 6.25 4 100 5 6 7 8 9 10 11 12 6.25

Endocrine Manual Brown et al. 2005

47

TESTOSTERONE EIA Day1: 1. Plate Coating Use NUNC Maxisorb plates Add 66.7 l antibody stock (1:100, -20C) to 5 ml coating buffer (working dilution 1:7500) Add 50 l per well of antibody solution to plate. do not coat column 1 - start at A2 and go down each column (see plate map). Pipet all solutions in this order. Tap plates gently to ensure that coating solution covers bottom of well Label, cover with acetate plate sealer and leave overnight (no less than 12 hrs) at 4C. Day 2: 2. Standards Standard values used are: 600, 300, 150, 75, 37.5, 18.8, 9.4, 4.7 and 2.3 pg/well Dilute standard working stock (12,000 pg/ml or 600 pg/well) serially (2-fold) by using 250 l stock plus 250 l EIA buffer. 3. Samples/controls Dilute urine or fecal samples in dilution buffer to appropriate dilution. Prepare High and Low controls 4. HRP Testosterone HRP working dilution is 1:15,000. Add 33.3 l of HRP working stock to 5 ml EIA buffer to make the working dilution (keep this solution cool). 5. Plate washing Wash the plate five times with wash solution. Blot the plate on paper towel to remove excess wash solution. 6. Plate loading Pipet 50 l of standard, control and samples per well as quickly and accurately as possible, according to plate map. Add 50 l of diluted testosterone HRP (step 4) to all wells that contain standard, control, or sample. Avoid splashing. No more than 10 minutes should pass during this process. Cover plates with acetate plate sealer and incubate at room temperature for exactly 2 hours. 7. Plate washing Wash the plate five times with wash solution. Blot the plate on paper towel to remove excess wash solution. Plates are fairly stable at this point and can be left upside down on bench top until all plates are washed (no more than 20 minutes).

Endocrine Manual Brown et al. 2005

48

8. Substrate Prepare ABTS substrate immediately before use (within 20 min). Combine 40 l 0.5 M H2O2, 125 l 40 mM ABTS and 12.5 ml substrate buffer, and mix well. Add 100 l ABTS substrate to all wells that contain standard, control, or sample. Cover with plate sealer and incubate at room temperature with shaking. Plate color development will vary based on age of HRP and/or Ab, but should be no greater than one hour. 9. Plate reading Optical density (OD) of 0 wells should read 1 or less. Optimal readings for 0 wells: > 0.7 to < 1 OD. Read at 405 nm (reference 540 nm).
TESTOSTERONE STOCK PREPARATION per plate

1. Antibody Dilute Polyclonal anti-testosterone R156/7 at a dilution of 1:100 by adding 20 l of stock to 2 ml of coating buffer. Aliquot 300-400 l into O-ring vials and store at -20C. Store antibody stock at -80C. 2. HRP Conjugate Dilute testosterone-horseradish peroxidase (HRP) 1:100 by adding 25 l of stock to 2.475 ml EIA buffer for a working stock and store at 4C. Store HRP stock at -80C. 3. Standards Weigh out 1 mg 17-hydroxy-4-androsten-3-one (Steraloids Cat. #A6950) and add to 1 ml ETOH for a 1 mg/ml primary stock. Dilute 1 mg/ml primary stock 1:100 by adding 100 l to 10 ml ETOH for a 10 g/ml secondary stock. Dilute 10 g/ml (10,000 ng/ml) secondary stock 1:100 by adding 250 l to 24.75 ml EIA Buffer for a 100 ng/ml tertiary stock. Dilute 100 ng/ml tertiary stock 1:8.33 by adding 12 ml to 88 ml of EIA Buffer for a 12,000 pg/ml (600 pg/well*) working stock. Aliquot working stock and store all stocks at -20C. * a well is equal to 50 l, the amount used in the assay. 4. Controls Use urine or extracted fecal samples with a high testosterone level to make controls. Make a pool of high testosterone level urine or extracted feces (~20ml). Serially dilute pool and run on assay. Find the dilutions that bind at ~70% and ~30%. Use the pool to make up two separate stocks for low and high controls using the dilutions that bound at 70% and 30% respectively. Make up enough controls to run on at least 500 assays (for this you may need more than the 20ml used for the pool. Any species will do so long at the urine has high testosterone levels.)

TESTOSTERONE EIA Template

Endocrine Manual Brown et al. 2005

49

ASSAY DATE

SPECIES ANIMAL ID DILUTION 1 Blank 2 0 3 18.8 4 300 5 6 7 8 9 10 11 12 18.8

A 37.5 B 2.3 C 150 D 4.7 E 2.3 F 9.4 G 9.4 H 0 150 C2 4.7 0 600 75 C1 0 300 37.5 600 75

Endocrine Manual Brown et al. 2005

50

ESTRONE CONJUGATE (EC R522-2) EIA Day 1: 1. Plate Coating Use NUNC Maxisorb plates. Add 12.5 l antibody stock (1:100, -20C) to 5 ml coating buffer (working dilution 1:40,000). Add 50 l per well of antibody solution to plate. do not coat column 1 - start at A2 and go down each column (see plate map). Pipet all solutions in this order. Tap plates gently to ensure that coating solution covers bottom of well. Label, cover with acetate plate sealer and leave overnight (no less than 12 hrs) at 4C. Day 2: 2. Plate washing Wash the plate five times with wash solution. Blot the plate on paper towel to remove excess wash solution. do not allow coated plates to dry - immediately add 50 l EIA assay buffer per well. Incubate plate at RT for 2 - 5 hours. 3. Standards Standard values used are: 200, 100, 50, 25, 12.5, 6.25, 3.12, 1.56 and 0.78 pg EC/well. Dilute standard working stock (200 pg/well or 10 ng/ml) serially (2-fold) by using 200 l stock plus 200 l EIA buffer. 4. Samples/controls Dilute urine or fecal samples in dilution buffer to appropriate dilution. Prepare High and Low controls 5. HRP EC-HRP working dilution is 1:25,000. Add 20 l of HRP working stock to 5 ml EIA buffer to make the working dilution (keep this solution cool). 6. Plate loading Pipet 20 l of standard, control and samples per well as quickly and accurately as possible, according to plate map. Add 50 l of diluted EC HRP (step 5) to all wells that contain standard, control, or sample. Avoid splashing. No more than 10 minutes should pass during this process. Cover plates with acetate plate sealer and incubate at room temperature for exactly 2 hours. 7. Plate washing Wash the plate five times with wash solution. Blot the plate on paper towel to remove excess wash solution. Plates are fairly stable at this point and can be left upside down on bench top until all plates are washed (no more than 1 hour).

Endocrine Manual Brown et al. 2005

51

8. Substrate Prepare ABTS substrate immediately before use (within 20 min). Combine 40 l 0.5 M H2O2, 125 l 40 mM ABTS and 12.5 ml substrate buffer, and mix well Add 100 l ABTS substrate to all wells that contain standard, control, or sample. Cover with plate sealer and incubate at room temperature with shaking. Plate color development will vary based on age of HRP and/or Ab, but should be no greater than one hour. 9. Plate reading Optical density (OD) of 0 wells should read 1 or less. Optimal readings for 0 wells: > 0.7 to < 1 OD. Read at 405 nm (reference 540 nm).
EC (EC R522-2) STOCK PREPARATION per plate

1. Antibody Dilute polyclonal anti-EC R522-2 at a dilution of 1:100 by adding 20 l of stock to 2 ml of coating buffer. Aliquot 300-400 l into O-ring vials and store at -20C. Store antibody stock at -80C. 2. HRP Conjugate Dilute estrone-glucuronide-horseradish peroxidase 1:100 by adding 50 l of stock to 4.95 ml EIA assay buffer for a working stock and store at 4C. Store HRP stock at -80C. 3. Standards Weigh out 1 mg estrone-glucuronide (Sigma Cat. #E 1752) and add to 100 ml ETOH for a 10 g/ml primary stock solution. Dilute 10 g/ml primary stock 1:1,000 by adding 100 l to 100 ml EIA buffer for a 10 ng/ml (200 pg/well*) working stock. Aliquot working stock and store all stocks at -20C. * a well is equal to 20 l, the amount used in the assay. 4. Controls Use urine or extracted fecal samples with a high estrogen level to make controls. (samples collected during estrus are best). Make a pool of high estrogen level urine or extracted feces (~20 ml). Serially dilute pool and run on assay. Find the dilutions that bind at ~70% and ~30%. Use the pool to make up two separate stocks for low and high controls using the dilutions that bound at 70% and 30% respectively. Make up enough controls to run on at least 500 assays (for this you may need more than the 20 ml used for the pool. Any species will do so long at the urine has high estrogen levels).

Endocrine Manual Brown et al. 2005

52

EC (R522-2) EIA Template


ASSAY DATE SPECIES ANIMAL ID DILUTION 1 Blank A 12.5 B 0.78 C 50 D 1.56 E 0.78 F 3.12 G 3.12 H 0 50 C2 1.56 0 200 25 C1 0 100 12.5 200 25 2 0 3 6.25 4 100 5 6 7 8 9 10 11 12 6.25

Endocrine Manual Brown et al. 2005

53

XVII. ASSAY REAGENTS AND SUPPLIES 1. STEROID EIA ASSAY RECIPES (full and half recipes) COATING BUFFER Full Half Na2CO3 (Anhydrous) 1.59 g 0.795 g NaHCO3 2.93 g 1.465 g H 2O 1000 ml 500 ml pH to 9.6, store at 4C

(Sigma, S2127) (Sigma, S8875)

STOCK A 27.8 g 13.9 g (Sigma, S9638) Stock A 0.2M NaH2PO4 H 2O 1000 ml 500 ml STOCK B 28.4 g 14.2 g (Sigma, S0876) Stock B 0.2M Na2HPO4 H 2O 1000 ml 500 ml ASSAY BUFFER (EIA BUFFER) Stock A 195 ml 97.5 ml Stock B 305 ml 152.5 ml NaCl 8.7 g 4.35 g (Sigma, S9625) BSA 1.0 g 0.5 g (Sigma, A7906) H 2O 500 ml 250 ml o pH to 7.0, store at 4 C Dilution buffer for fecal extraction is EIA buffer minus the addition of BSA. WASH SOLUTION CONCENTRATE NaCl 87.66 g 43.83 g (Sigma, S9625) Tween 20 5.0 ml 2.5 ml (Sigma, P1379) H 2O 1000 ml 500 ml store at 4C Dilute 10-fold for working wash soln. (i.e.100 ml wash concentrate plus 900 ml H2O), store at RT SUBSTRATE BUFFER Citric acid (anhydrous) H 2O pH to 4.0, store at 4C

9.61 g 1000 ml

4.805 g 500 ml

(Sigma, C0759)

ABTS (40 mM) ABTS 0.55 g (Sigma, A1888) H 2O 25 ml pH to 6.0. ABTS is light sensitive - use brown glass or foil for storage o store at 4 C HYDROGEN PEROXIDE (0.5M) H2O2 (30% Solution) 500 l H 2O 8 ml store at 4C 2. CREATININE ASSAY RECIPE NaOH (0.75 N) NaOH Pellets H 2O This is a strong base so keep in a glass bottle Picric Acid (0.4 M)

(Sigma, H1009)

3.0 g 100 ml

Endocrine Manual Brown et al. 2005

54

Saturated Picric acid H 2O OR. Crystallized Picric acid in H2O H 2O


Safety Precautions

100 ml 900 ml

S925-40

5g 500 ml

S4255

Picric Acid - Saturated Solution Store tightly capped - explosive when dried Store in a flame proof cabinet Poisonous - avoid contact with eyes and mouth Irritant - avoid contact with skin - wear gloves when handling Dilute 1:100 in dH2O for working solution Flush with water for 5 minutes if it contacts skin or eyes Flush with water for 5 minutes when disposing diluted solution down the drain Incompatible with metals, oxidizing and reducing agents, strong bases, ammonia, concrete and plaster

Endocrine Manual Brown et al. 2005

55

Assay Reagents for Steroid enzymeimmunoassays:

Na2CO3 NaHCO3 NaH2PO4 Na2HPO4 NaCl BSA Tween 20 Citric acid ABTS H 2O 2 Tris (Trizma base) Sodium azide Tween 80 Phosphate citrate buffer (with sodium perborate capsules) TMB H2SO4 HCL NaOH pellets

Sigma, S-2127 Sigma, S-8875 Sigma, S-9638 Sigma, S-0876 Sigma, A-7906 Sigma, P-1379 Sigma, C-0759 Sigma, A-1888 Sigma, H-1009 Sigma, T-1503 Sigma, S-8032 Sigma, P-1754 Sigma, P-4922

FW=106.0 FW=84.01 MW=138.00 MW=142.00

Anhydrous Monobasic Dibasic Enzyme Grade Fraction V Anhydrous 30% w/w solution Reagent Grade

1kg 1kg 1kg 1kg 100g 500ml 500g 5g 500ml 1kg 500ml

FW=192.1 FW=34.01 FW=121.1

Good for plates.

100-500

100 capsules 100 tablets

Sigma T-3405 FW=98.08

Sigma, S-5881

Needed for pH 1) pH 2) Crt assay whole molecule purified Boehringer End up with 0.4M solution

Anti-mouse IgG Streptavidin Picric acid 1) Saturated 2) Crystalized in H20

Sigma M8645 Roche Diagnostics 1089153 1) Sigma, 925-40 2) Sigma, C4255

Good for 50 plates Reagent grade Make a 0.6M solution Reagent grade 1) 2) need 0.75M (3.0g in 100ml H2O) Good for 20 plates Will last ~ 6 months 1) Dilute saturated stock 1:100 in H2O 2) Weigh out 5g (using plastic) into 500ml H20 For fecal extraction use ~ 20ml/extraction For fecal extraction use 1ml/extraction

1mg 500U CAUTION: Explosive when dried/ poisonous /irritant

Creatinine Standards Ethyl Alcohol

Sigma, 925-11 Dehydrated proof Reagent grade 200

Methanol

Endocrine Manual Brown et al. 2005

56

Supplies Mircotitre plates and Sealers Small Glass Tubes and Racks Large Glass Tubes and Racks Small Plastic Tubes

Large Plastic tubes and/or baggies O-ring vials Freezer Boxes and grids

Nunc mircotitre 96 flat well plates Maxisorp Mircotitre plate sealer 12 x 75 mm glass culture tubes Rack - 72 holes, holds 10-13mm 16 x 125 mm glass culture tubes Rack - 72 holes, holds 16mm tubes Clear 12 x 75 mm plastic tubes Purple 12 mm stopper caps Conical tubes (50 ml) blue caps ziplock bags with white write-on labels

Supplier 1 Supplier 2 For running EIAs

HX 24870A 12-565-135 3501 14 961 26 60917-500

Daigger Fisher Scientific Dynex Laboratories Fisher Scientific VWR Fisher Scientific

For boiling extracts

fecal

14-961-30

To store neat urine and fecal extracts

62-526-003 65-809-003

Sarstedt Inc. Sarstedt Inc. Perfector Scientific

To store fecal samples

2650

To store antibody Daigger cardboard storage boxes and lids, 3" Daigger cardboard storage box grids (100 cell) 500 ml Store for urine and extracted fecal samples LX2860BX LX2860EX

Sarstedt Inc. Daigger Daigger

Plastic wash bottles

For washing plates and rinsing glassware

Need 3

Endocrine Manual Brown et al. 2005

57

EQUIPMENT Pipettes Pipette (Brinkman and Tips Eppendorf 20) Pipette (Brinkman Eppendorf 100) Pipette (Brinkman Eppendorf 200) Pipette (Brinkman Eppendorf 1000) 200ul tips 1000ul tips Repeater Repeater (Brinkman and Tips Eppendorf) Repeater Fisher brand Dispenser Tips Vortex PH meter Calibrators (pH 4, 7, 10), rinse and holding rack Sonicator For fecal extractions Magnetic And magnets mixer Glass 1 litre Bottles Plate Shaker Boiling H20 bath Drying Multitube manifold apparatus Centrifuge To spin 16 x 125 mm tubes for fecal extraction

05-402-87 05-402-88 05-402-89 05-402-90 1670-Y 21-380-8 2.5ml, 5ml, 25ml, 50ml 12.5ml,

Fisher Scientific Fisher Scientific Fisher Scientific Fisher Scientific Perfector Scientific Fisher Scientific

Need 3-4

To hold buffers Should hold up to 4 plates at a time For fecal extraction To dry extracts down fecal

Need 10

Rubber mallet Scale

Plate Reader and Printer

One to weigh out fecals and One to weigh out chemicals Must have 450nm and 405nm filters; reference filter 540nm or above

To pulverize dried fecal samples Both Sensitivity of 0.000g

Need 3-4

Extra Filters and lamps Manuel Disks for revelation software

Printer

Endocrine Manual Brown et al. 2005

58

OTHER Timer Sharpie Markers Kimwipes Parafilm Calculator Glass Scintillatio n vials Clipboards Protocols and Assay sheets Colored Tape Good H20 Milli-Q, supply deionized or osmosis Adaptors Plate Reader and Printer voltage converts for equipment

Hard and copies Covers

disk

distilled, reverse

Critical element

Endocrine Manual Brown et al. 2005

59

XVIII. REVIEW OF STEROID METABOLISM Adapted from: Th. Steimer, Division of Clinical Psychopharmacology, University Institute of Psychiatry,2, ch. du Petit Bel-Air, 1225 Chne-Bourg, Geneva, Switzerland Introduction

Steroids are lipophilic, low-molecular weight compounds derived from cholesterol that play a number of important physiological roles. The steroid hormones are synthesized mainly by endocrine glands such as the gonads (testis and ovary), the adrenals and, during gestation, by the fetoplacental unit, and are then released into the blood circulation. They act both on peripheral target tissues and the central nervous system (CNS). An important function of steroid hormones is to coordinate physiological and behavioral responses for specific biological purposes, like reproduction. Thus, gonadal steroids influence the sexual differentiation of the genitalia and of the brain, determine secondary sexual characteristics during development and sexual maturation, contribute to the maintenance of their functional state in adulthood and control or modulate sexual behavior. Despite their relatively simple chemical structure, steroids occur in a variety of biologically active forms. This is due in part to the fact that circulating steroids are extensively metabolized by the liver and in target tissues where conversion to an active form is sometimes required. Steroid metabolism is therefore important not only for the production of these hormones, but also for the regulation of their cellular and physiological actions.
Steroid hormones: Structure, nomenclature and classification

The parent compound from which all steroids are derived is cholesterol. As shown in Fig. 1a, cholesterol is made up of three hexagonal carbon rings (A,B,C) and a pentagonal carbon ring (D) to which a side-chain (carbons 20-27) is attached (at position 17 of the polycyclic hydrocarbon). Two angular methyl groups are also found at position 18 and 19. Removal of part of the side-chain gives rise to C21-compounds termed pregnanes (progestins and corticosteroids). Total removal produces C19-steroids, androstanes (including the androgens), whereas loss of the 19-methyl group (usually after conversion of the A-ring to a phenolic structure, hence the term "aromatization") yields the estranes, to which estrogens belong. Individual compounds are characterized by the presence or absence of specific functional groups (mainly hydroxy, keto(oxo) and aldehydes groups) on the carbon skeleton. Given that at most positions, the functional groups can be oriented either in equatorial or axial position (see Fig. 1b), this type of structure gives rise to a great number of possible stereoisomers (i.e., molecules having the same chemical formula, but a different three-dimensional conformation). Stereoisomerism is very important for biological activity (i.e., for steroid-protein interactions). Substituent groups above the plane of the molecule are said to be in the "" position, whereas those situated under the plane of the molecule are said to be in the " " position. Double-bonds are indicated by the suffix -ene. A complete description of a steroid molecule must therefore include the name of the parent compound (pregnane, androstane or estrane series), and the name, number, position and orientation ( or ) of all functional groups. Commonly occurring steroids are usually identified by a "trivial" name (e.g., cortisol, testosterone, etc.). Thus, testosterone (trivial name) becomes "17-hydroxy-androst-4-ene-3-one". Steroid hormones can be grouped in various classes according to a number of criteria. Based on their chemical structure they can belong to one of the classes (series) mentioned above (e.g., "a pregnane derivative"). If their site of production is considered to be more important, one can distinguish for example between "ovarian" or "adrenal" steroids. If their biological function is essential, terms like "a glucocorticoid" or "sex steroids" can be used. Finally, classification can also be based on their molecular actions ("an estrogen-receptor agonist") or biochemical effects.
Steroid hormone biosynthesis A general outline of the major biosynthetic pathways

The adrenals produce both androgens and corticosteroids (mineralo- and glucocorticoids), the ovaries (depending on the stage of the ovarian cycle) can secrete estrogens and progestins, and the testis mainly androgens. However, the biochemical pathways involved are strikingly similar in all tissues, the difference in Endocrine Manual Brown et al. 2005

60

secretory capacity being mostly due to the presence or absence of specific enzymes. It is therefore possible to give a general outline of the major biosynthetic pathways which is applicable to all steroid-secreting glands, as shown in Fig. 2.
From acetate to cholesterol

Cholesterol can be synthesized in all steroid-producing tissues from acetate, but the main production sites are the liver, the skin and the intestinal mucosa. Steroid hormone formation in endocrine glands probably relies mostly on exogenous cholesterol (plasma cholesterol). The 27-carbon skeleton of cholesterol is derived from acetyl-CoA through a series of reactions which involve the following intermediate products: (1) Mevalonate (by condensation of 3 molecules of acetyl-CoA), which requires the enzyme HMG-CoAreductase, an important enzyme in the control of cholesterol biosynthesis; (2) Squalene, a 30-carbon linear structure which undergoes cyclization to yield (3) Lanosterol; and (4) after removal of 3 carbons, cholesterol.
From cholesterol to progestins, androgens and estrogens

The first committed step in steroid biosynthesis is the conversion of the 27-carbon skeleton of cholesterol to a C21-compound, pregnenolone (Fig. 2). This critical step, which is subject to hormonal control by adrenocorticotropic hormone (ACTH) in the adrenals and by luteinizing hormone (LH) in the gonads, is catalyzed by a P-450 enzyme, the cholesterol side-chain cleavage enzyme P-450scc (also called 20,22desmolase, or 20,22-lyase). Pregnenolone can be converted either to progesterone, which branches to the glucocorticoid and androgen/estrogen pathways, or to 17 -hydroxypregnenolone, which is another route for the formation of androgens and estrogens (Fig. 2, top-left part). Androgen formation in the adrenals is limited to dehydroepiandrosterone and androstenedione, whereas in the testes 17-hydroxysteroid dehydrogenase (17HSD) in Leydig cells (under the control of LH) stimulates production of testosterone, the principal "male" hormone. Estrogen formation requires another P-450 enzyme, the aromatase complex (P450Arom). The substrate is either androstenedione (for estrone) or testosterone (for estradiol). Estrone and estradiol are interconvertible through a reversible reaction involving another 17-hydroxysteroid dehydrogenase, as in the androstenedione-testosterone conversion. Aromatase activity is present in the ovary and the placenta. In the ovary, aromatase activity and estrogen formation occur in granulosa cells and are controlled by follicle-stimulating hormone (FSH), whereas production of the androgenic substrates (testosterone, 4-androstenedione) requires LH stimulation of the theca cells.
From progesterone and 17-hydroxyprogesterone to gluco- and mineralocorticoids.

Hydroxylation of progesterone at carbon 21 yields 11-deoxycorticosterone (DOC), and corticosterone after another hydroxylation step at carbon 11. Corticosterone is a major glucocorticoid in rats and other species (e.g., birds), which do not produce cortisol. Two further steps (hydroxylation and oxydoreduction at carbon 18) result in the formation of aldosterone. Cortisol is formed from 17 -hydroxyprogesterone, with 11deoxycortisol as an intermediate. Cortisol is the main glucocorticoid secreted by the adrenal glands in most mammals.
Steroid hormones in the blood

It is generally assumed that steroids are released into the blood circulation as soon as they are formed, i.e. there are no active transport and/or release mechanisms. Secretion rates are therefore directly related to the biosynthetic activity of the gland and to the blood flow rate.
Steroid binding proteins

Because of their lipophilic properties, free steroid molecules are not highly soluble in water. In biological fluids they are usually found either in a conjugated form, i.e. linked to a hydrophilic moiety (e.g. as sulfate or glucuronide derivatives) or bound to carrier proteins (non-covalent, reversible binding). Binding to plasma albumin (which accounts for 20-50% of the bound fraction) is rather unspecific, whereas binding to either corticosteroid-binding globulin (CBG) or sex hormone-binding globulin (SHBG) [sometimes called "sex steroid-binding protein", or SBP] is based on more stringent stereospecific criteria. The "free fraction" (110% of total plasma concentration) is usually considered to represent the biologically active fraction (i.e., hormone that is directly available for action), although this idea has been challenged by recent evidence that, in some cases at least, the specific binding proteins may facilitate steroid entry into target tissues. Apart from the two functions mentioned above, the major roles of plasma binding proteins seem to be (a) to act as a "buffer" or reservoir for active hormones (because of the non-covalent nature of the binding, protein-bound steroids are released into the plasma in free form as soon as the free concentration drops according to the

Endocrine Manual Brown et al. 2005

61

law of mass action) and (b) to protect the hormone from peripheral metabolism (notably by liver enzymes) and increase the half-life of biologically active forms.
Peripheral metabolism of circulating steroids

Because steroids are lipophilic, they diffuse easily through the cell membranes, and therefore have a very large distribution volume. In their target tissues, steroids are concentrated by an uptake mechanism, which relies on their binding to intracellular proteins (or "receptors", see below). High concentrations of steroids are also found in adipose tissue, although this is not a target for hormone action. In the human male, adipose tissue contains aromatase activity, and seems to be the main source of androgen-derived estrogens found in the circulation. But most of the peripheral metabolism occurs in the liver and to some extent in the kidneys, which are the major sites of hormone inactivation and elimination, or catabolism (see below).
Steroid interaction with target tissues Formation of active metabolites in target tissues

For certain classes of hormones and particular target tissues, steroids must be converted in situ to an active form before they can interact with their specific receptor(s). For example, conversion of testosterone to 5 DHT (Fig. 3, top) is required for its action on prostate growth and function, whereas aromatization to estradiol-17 in the brain is mandatory for some of its developmental, neuroendocrine and behavioral effects. Unlike its parent compound, the progesterone metabolite 5 -DHP (Fig. 3, bottom) has no effect on the uterus, but is more effective than progesterone itself regarding the facilitation and/or inhibition of GnRHinduced LH release in vitro. The two main classes of hormones for which metabolic activation has been shown to play a role are the progestins and the androgens, but catecholestrogens (2- or 4-OH derivatives of estrogens) may also constitute another class of biologically active compounds resulting from target organ metabolism.
Correlation between structure and function: the role of metabolism

The biological activity of a steroid molecule depends on its ability to interact with a specific binding site on the corresponding receptor. In most cases, biological activity can be directly correlated with binding affinity. The affinity (usually characterized by the binding constant KD, which is the molar concentration required to saturate half of the available binding sites) of a steroid for its specific receptor is dependent upon the presence or absence of particular functional groups and the overall three-dimensional structure of the molecule. Stereoisomerism may play an important role in this respect: molecules with the same chemical composition but a different spatial orientation of their substituents may have totally different binding properties and biological effects. Thus, 5 -reduced dihydrotestosterone (DHT) is a potent androgen, with a strong affinity for intracellular androgen receptors, whereas its 5-epimers do not bind to these receptors and are totally devoid of androgenic properties.
Steroid inactivation and catabolism General principles

Inactivation refers to the metabolic conversion of a biologically active compound into an inactive one. Inactivation can occur at various stages of hormone action. Peripheral inactivation (e.g., by liver enzymes) is required to ensure steady-state levels of plasma hormones as steroids are more or less continuously secreted into the bloodstream. Moreover, if a hormone is to act as a "chemical signal", its half-life in the circulation must be limited so that any change in secretion rate is immediately reflected by a change in its plasma concentration (particularly when secretion rates are decreased). But hormone inactivation can also occur in target tissues, notably after the hormone has triggered the relevant biological effects in order to ensure termination of hormone action. The main site of peripheral steroid inactivation and catabolism is the liver, but some catabolic activity also occurs in the kidneys. Inactive hormones are mainly eliminated as urinary (mostly conjugated) metabolites. Usually, steroids are eliminated once they have been inactivated (i.e., they are not "recycled"). This elimination requires conversion to hydrophilic compounds in order to ensure their solubility in biological fluids at rather high concentrations. A few examples of steroid excretion products are shown in Table 1.
Formation of steroid conjugates

Conjugation (formation of hydrophilic molecules) is an important step in steroid catabolism. Most excretory products in urine are in conjugated form. Two major pathways are used: Endocrine Manual Brown et al. 2005

62

1. Formation of glucuronides. This reaction requires uridine diphosphoglucuronic acid (UDPGA) and a glucuronyl transferase. Glucuronic acid is attached to a HO-group on the steroid molecule. 2. Formation of sulphates. This conversion is catalyzed by sulphokinases, which occur in the cytosol of liver, testicular, adrenal and fetal tissues. The substrates are steroids with an HO-group and phosphoadenosine-5-phosphosulphate (PAPS). Two examples of conjugated derivatives are shown in Fig. 4. In addition to being excretory products, sulphates are also found in endocrine tissues and/or the plasma as precursors for hormone synthesis. This is the case of dehydroepiandrosterone sulphate (DHEAS), which is used notably for estrogen biosynthesis in the fetoplacental unit. Sulphatases occurring in the microsomal fraction of liver, testis, ovary, adrenal and placenta catalyze the hydrolysis of sulphated steroids to free steroids. The digestive juice of the snail Helix pomatia contains both sulphatase and glucuronidase activity, and extracts from this source are used to hydrolyse urinary conjugates in vitro for clinical assessment of total and conjugated excretion products. In most species, fecal steroid metabolites are not excreted in a conjugated form, although exceptions exist (e.g., felids).
Summary

Metabolism plays many important roles in steroid hormone action. Various biosynthetic pathways occurring in endocrine glands such as the gonads, the adrenals and the fetoplacental unit are required to produce and secrete circulating hormones. These hormones are partly metabolized in the periphery, either before reaching their target tissues (to control plasma levels of active compounds), or after termination of their action (inactivation and elimination). But many of them are also metabolized within their target tissues, where a complex interplay between activation and inactivation mechanisms serves to regulate the specificity and the amplitude of the hormonal response. The proportion of steroid excreted in urine or feces usually is species or taxon specific. For example, most felids excrete >90% of gonadal steroids into feces, whereas baboons excrete >80% of gonadal steroids into urine. Steroids vary in the extent to which they are metabolized before excretion, both within and among individuals and species. The time course of steroid excretion and the degree to which steroids are excreted in urine or feces are determined by infusing unlabeled or radiolabeled steroid and quantifying hormonal metabolites in excreta. The lag-time from steroid production/secretion to appearance in excreted urine is generally <12 hours, but can range from 12-24 hours in ruminants and 24-48 hours in primates and hindgut fermenters.

Endocrine Manual Brown et al. 2005

63

1a

1b

FIGURE 1. Structure and classification of steroid hormones. (a) Top: structure of cholesterol, with numbering of carbons (1 to 27) and identification of cycles (A to D). Bottom: The three main classes of steroids ("parents compounds") derived from cholesterol, with number of carbons in brackets (C21 to C18). Pregnanes (C21) form the basic structure of progestins and corticosteroids, Androstanes (C19) of androgens and Estranes (C18) of estrogens (with of phenolic A- ring). (b) Three-dimensional conformation of naturally occurring steroid hormones. Functional groups (or hydrogen atoms) are either in axial (a) or equatorial (e) position. Functional groups (or hydrogens) above the plane of the molecule are said to be in the " " position (e.g. the HO-group at C), those below the plane in " " position (e.g. the hydrogen at position C5, bottom figure). Orientation of substituents at certain positions can be critical for the overall conformation of the molecule. Thus, orientation of the hydrogen atom at the A-B ring junction (marked by open circles in Fig. 1b) will determine whether the A and B rings are fused in a trans- (as in the molecule on top) or cis- (bottom drawing) conformation. This type of conformation (trans- or cis- A-B ring fusion) is often critical for biological activity. For example, 5 -DHT (see Fig. 3) has androgenic properties not shared by its 5-reduced analog, 5-DHT.

Endocrine Manual Brown et al. 2005

64

FIGURE 2. Major Pathways of Steroid Biosynthesis. The pathways outlined here are common to the adrenals, the gonads and, to some extent, to the fetoplacental unit. The first committed step is the conversion of cholesterol to pregnenolone, catalyzed by the P-450scc enzyme, which is under pituitary hormone control (ACTH or LH depending on the tissue). Cholesterol side-chain removal is blocked specifically by aminoglutethimide, a steroid biosynthesis inhibitor. From pregnenolone, steroid biosynthesis can proceed either through the so-called "delta-5" pathway (17 hydroxypregnenolone, dehydroepiandrosterone, testosterone), or through the "delta-4" pathway (progesterone onwards). Progesterone is the starting point for mineralocorticoid synthesis, whereas glucocorticoids are derived from its metabolite, 17 -hydroxyprogesterone. Estrogens are formed from androgens (androstenedione and/or testosterone). Most reactions are irreversible (as denoted by a single arrow). Reversible reactions (double arrows) depend on cofactor availability (e.g. the NADP/NADPH ratio). [Abbreviations used here for the various enzymes are listed in the figure].

Endocrine Manual Brown et al. 2005

65

FIGURE 3. Steroid metabolism in target tissues. Two examples showing pathways of steroid metabolism in target tissues, which results in the formation of biologically active metabolites. Top: 5 -reduction (left) or aromatization (right) of testosterone. Bottom: 5 reduction (left) or 5-reduction (right) of progesterone.

Endocrine Manual Brown et al. 2005

66

TABLE 1. Steroid excretion products (examples) Steroid class Excretion product Type of conjugate

Progestins

Progesterone 17 hydroxyprogesterone

Pregnanediol Pregnanetriol Androsterone

Glucuronide Glucuronide

Androgens

Testosterone Etiocholanolone

Glucuronide and/or Sulphate

11-hydroxyandrosterone Glucocorticoids Cortisol Allotetrahydrocortisone Glucuronide

FIGURE 4. Glucuronide and sulphate derivatives. Testosterone glucuronide (left) and estrone sulphate (right), two steroid conjugates found in human urine as excretory product for testosterone and estrone, respectively.

Endocrine Manual Brown et al. 2005

67

XIX. REVIEW OF REPRODUCTIVE PHYSIOLOGY

Reproduction is controlled by the complex interaction of hormones within the GnRH hypothalamo-hypophyseal-gonadal (HHG) Progesterone axis as shown in Figure 1. In brief, & Estradiol Testosterone gonadotropin-releasing hormone (GnRH) from the hypothalamus stimulates the FSH LH release of gonadotropins, LH and FSH, from the anterior pituitary gland. In the female, gonadotropins are responsible for follicular development, ovulation and corpus luteum function. In the male, these same hormones stimulate testicular development, spermatogenesis and testosterone production. In both males and females, Oocyte products from the gonads (e.g., estradiol, Figure 1. Example of hormonal interactions within the Testis Ovary Tubule formation progesterone, inhibin, testosterone) Follicle development HHG axis. Sperm production Ovulation feedback to the pituitary gland and Leydig cell function CL development hypothalamus to regulate secretion of the gonadotropins. Thus, gonadal activity is tightly regulated by the interaction of intrinsic stimulatory factors and resulting products. Reproduction also is affected by external factors, many of which are seasonally mediated (e.g., nutrition, photoperiod, climate). When studying a new species it is important to collect data for periods exceeding one year to determine the influence of season or other extrinsic factors on reproductive activity.
Hypothalamus Female reproduction Ovarian cycle dynamics are particularly complex and mechanisms of control not completely understood. In general, during mammalian reproductive cycles a species-specific number of follicles is selected to complete differentiation and ovulate. This occurs after regression of the corpus luteum and withdrawal of progesterone. In most species, ovulation will not occur until this progesterone block is removed. During the early follicular phase in mammals such as cattle, horses and primates, after the recruitment of a cohort of follicles, one follicle is selected to become dominant and continues to grow, while growth of the subordinate follicles is curtailed. Shortly after selection, concentrations of gonadotropin receptors and steroidogenic enzymes increase in the dominant follicle. The granulosa cells of the selected follicle acquire LH receptors to allow them to increase aromatization in response to LH as well as FSH. The increased P450 aromatase activity within the follicle causes an increase in concentrations of estradiol that eventually elicits the preovulatory LH/FSH surge. Recent evidence also suggests that intrafollicular insulinlike growth factor (IGF) synergizes with FSH to promote follicular growth and aromatization and helps complete dominant follicular selection. After ovulation, LH works to reorganize the collapsed follicle into a corpus luteum and initiates and maintains progesterone production. If the female becomes pregnant, the corpus luteum is maintained and progesterone of luteal and/or placental sources sustains the pregnancy. If conception does not occur, prostaglandin-F2 and/or estrogens of uterine and/or ovarian sources cause luteal regression and the ovarian cycle begins again.

Endocrine Manual Brown et al. 2005

68

The female ovarian cycle Spontaneous ovulation

Follicle Development

Ovulation CL Development

Progesterone Estradiol LH

FSH

Females of some species are known as "induced ovulators" in that a mating or similar stimulus is required to induce the ovulatory LH surge and cause ovulation of the follicle. In these species, follicles grow and then regress with no luteal phase unless an ovulatory stimulus occurs. In many of these species, a nonpregnant luteal phase or pseudopregnancy results after non-conceptive matings. These luteal phases can be of similar (e.g., ferrets) or shorter

Figure 2. Longitudinal secretory profile of the major reproductive hormones during a spontaneous ovarian cycle.
(e.g., felids) duration than a pregnant luteal phase. In developing assisted reproductive techniques, like artificial insemination (AI) and in vitro fertilization/embryo transfer (IVF/ET), hormonal therapies are used to control reproductive processes. Thus, equine chorionic gonadotropin (eCG or PMSG), which has FSH-like activity, can stimulate follicular development, whereas human chorionic gonadotropin (hCG), which has LH-like activity, is used to induce ovulation (see Figure 1). Development of these technologies requires an understanding of the mechanisms controlling ovarian function and relies on the availability of adequate endocrine information to determine how well exogenous chorionic gonadotropin therapy mimics natural responses.
Male reproduction In the male, LH stimulates the production of testosterone from the interstitial cells, also known as Leydig cells. FSH is important for seminiferous tubule formation and works in conjunction with testosterone to stimulate spermatogenesis. Testosterone further acts to maintain secondary sex characteristics (e.g., lions mane, facial hair, increased muscle mass, colored plumage, etc.) and accessory sex gland function in part through local conversion to dihydrotestosterone (DHT), and sexual behavior. Non-invasive hormone monitoring Obviously, the ability to track gonadal activity is essential for understanding the fundamentals of reproduction. Fecal and urinary steroid metabolite monitoring are now well-established tools for evaluating reproductive processes in diverse mammalian species. Steroids are easily extracted from feces by boiling in 90% aqueous ethanol, whereas urinary steroids often are directly measurable by immunoassay using groupspecific antibodies that crossreact with excreted metabolites or metabolite conjugates. With assisted reproductive techniques, like AI and IVF/ET, becoming increasingly important for managing species ex situ, steroid metabolite monitoring has provided an especially useful tool for examining the efficacy of associated hormonal therapies on reproductive responses. Because of its enormous utility and noninvasive nature, excreted hormone metabolite monitoring has become one of the most powerful tools available in wildlife research today. XX. REVIEW OF ADRENAL PHYSIOLOGY
Day 0

Although not a reproductive hormone per se, the potential impact of cortisol (i.e., stress) on reproduction cannot be overlooked. Since the early 70s stress has become an increasingly popular and widely applied term and usually conjures up negative images; however, disagreements continue over a clear definition of the term. It has been defined as a general syndrome occurring in response to any stimulus that Endocrine Manual Brown et al. 2005

69

threatens or appears to threaten the homeostasis (or the physiological and physical integrity) of an individual. The stimuli are called stressors and the syndrome stress. It also has been described as the fight or flight response. This physiological stress response appears to have evolved as an adaptive mechanism that allows organisms to adjust to and cope with less predictable circumstances in their environment and to respond rapidly to a wide variety of stimuli. Thus, stress represents an important part of life and should not be considered inherently bad. Some researchers have recently argued that the term stress should only be used for events that are detrimental for an individual. However, it often is difficult to distinguish a normal and an adaptive response from ones that lead to negative effects. Although we can clearly identify some of the negative effects, we are not yet able to distinguish positive and negative stressors and associated responses reliably. The perception of a stressor by an organism activates the Hypothalamus hypothalamic-pituitary-adrenal (HPA) axis (see Figure 3). The hypothalamus releases CRF (corticotropin releasing factor), which stimulates the pituitary gland to secrete ACTH (adrenocorticotropin), thus causing the release of corticoids (often termed stress CRF hormones) from the adrenal gland. A number of acute events such CRF as mating, fighting, chasing, temperature shock, pain, etc. can evoke the stress response and activate the adrenal cortex. The resulting Anterior in heart gastro- intestinal Pituitary rapid changes designed rate, blood pressure, andquickly respond to activity are all to allow the organism to the situation. However, it is when acute stress occurs repeatedly without allowing for coping responses or recovery, and/or when the ACTH stress response is chronically activated that stress becomes a problem, called distress. An accumulation of biological costs a series a consistent chronic Adrenal through have beenof acutetostressors and/orpathological conditions, stressor shown lead to various such as immune deficiency, reproductive suppression, growth Gland reduction, muscle wasting, gastrointestinal dysfunction and impaired brain function. Thus, although acute stress can have a stimulatory or facilitatory effect on certain aspects of reproduction, chronic stress can lead to an overall inhibition of reproduction. Identifying early Cortisol symptoms of distress and pinpointing chronic as well as repetitive Fight or Flight response acute stressors is essential for evaluating animal well-being. Immune suppression However, it also must be recognized that responses to stress can be Reproductive inhibition very individual-specific. Animals born and raised in captivity may Figure 3. Hormonal interactions react very differently compared to their wild counterparts even when within the HPA axis. faced with the same stressors. In captivity many stressors have been removed, but the lack of stimulation in and of itself may present a source of distress due to boredom. Measuring stress and distress is difficult. No single biochemical or behavioral measure can be used to assess animal well-being or stress. Whereas behavioral observations may frequently provide a first indicator of distress, they can also be misleading. Similarly, measures of reproductive success, growth rate, and general health, although important for examining certain aspects of animal well-being, often are not reliable as early indicators of distress when examined by themselves. Only through a combination of these measure, including physiological analyses of circulating and excreted hormones like corticoids, can we begin to examine the influence of stress and distress on animal well-being. The recent development of non-invasive monitoring of adrenal steroids has provided a new tool for these investigations. Measuring glucocorticoid concentrations in blood samples has long been used as an indicator of stress in mammals. However, the invasive nature and inherent stress of collecting blood samples has limited its usefulness for studies on many captive and wild animals. Alternatively, fecal or urinary corticoid monitoring can be used in combination with behavioral observations and other measures of overall health in longitudinal studies without additional stress to the animal. Careful biochemical and physiological validation is necessary for the application of this technique and resulting measures cannot provide a litmus test for distress. Increases in excreted glucocorticoids may be due to negative (i.e., nonadaptive) or positive (i.e., adaptive) stress responses. Furthermore, glucocorticoid levels may decline due to intrinsic hormone control and negative feed back mechanisms rather than elimination or decrease of the external stressor. In addition, although a wide variety of stressors stimulate the HPA axis, not all types of

Endocrine Manual Brown et al. 2005

70

stressors will affect an increase in glucocorticoids. Nevertheless, the combined use of all available measures can help us better understand the impact of various stressors on animal well-being and make significant advances in our assessment of distress.

Endocrine Manual Brown et al. 2005

71

Potrebbero piacerti anche